(Hazardous Materials and Risk Assessment) Initial Survey : Noel Arnold & Associates : 05 - Apr - 2008 Greencap-NAA : 07 - May - 2015 School : Tamworth South Public School (3882) Asbestos Register Region : New England State Electorate : Tamworth Local Government Area : Tamworth Reviewed By : Register Issue Date : Thursday, 23 Mar 2017 Page 1 of 26 3882 - Tamworth South Public School

Transcript of (Hazardous Materials and Risk Assessment) · School : Tamworth South Public School (3882) Asbestos...

Page 1: (Hazardous Materials and Risk Assessment) · School : Tamworth South Public School (3882) Asbestos Register Region : New England State Electorate : Tamworth Local Government Area

(Hazardous Materials and Risk Assessment)

Initial Survey : Noel Arnold & Associates : 05 - Apr - 2008

Greencap-NAA : 07 - May - 2015

School : Tamworth South Public School (3882)

Asbestos Register

Region : New England

State Electorate : Tamworth

Local Government Area : Tamworth

Reviewed By :

Register Issue Date : Thursday, 23 Mar 2017 Page 1 of 263882 - Tamworth South Public School

Page 2: (Hazardous Materials and Risk Assessment) · School : Tamworth South Public School (3882) Asbestos Register Region : New England State Electorate : Tamworth Local Government Area

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

Status

Sample No

ControlPriority

3882 Tamworth South Public School 2017

Test Result

B00A - Administration/General Learning - 1956 - Brick/Veneer (Brick/Veneer)

Exterior

Eaves Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

20m2 South Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

Gable Verge Lining Flat AC Sheeting

3882/B00A/Gable Verge Lining/S17

12m2 Variable positions

Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

In-fill-panel Compressed AC Sheet

3882/B00A/R0001/Below window in-fill panels./S16

50m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos) , Amosite (brown

asbestos)

Low Priority (2-3)

Ceiling Voids No Asbestos Found

Underfloor Voids - Slab on Ground

No Asbestos Found

Interior

B00A - R0001 - Movement

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

72m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

Below window in-fill panels.

Flat AC Sheeting

3882/B00A/R0001/Below window in-fill panels./S16

13Unit South Good Condition (1) Medium (2)

Chrysotile (white asbestos) , Amosite (brown

asbestos)

Low Priority (2-3)

Above window infill panels.

Compressed AC Sheet

3882/B00A/R0001/Below window in-fill panels./S16

13Unit South Good Condition (1) Low (1)

Chrysotile (white asbestos) , Amosite (brown

asbestos)

Low Priority (2-3)

B00A - R0002 - Deputy Principal

Floor Coverings Res/Textile

Vinyl Tiles (Under Floor Covering/Carpet)

3882/B00A/R0004/Floor Coverings Res/Textile/S10

13m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00A - R0003 - General Storeroom

Floor Coverings Res/Textile

No Asbestos Found

B00A - R0004 - Sick Bay

Floor Coverings Res/Textile

Vinyl Tiles

3882/B00A/R0004/Floor Coverings Res/Textile/S10

9m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

Thermacon Heater Encapsulated Insulation material within unit

Assumed Asbestos - Encased in metal

1Unit Throughout Friable Asbestos (5) Low (1) Low Priority (2-3)

B00A - R0005 - Staff Toilet

No Asbestos

B00A - R0006 - Entry Vestibule

Floor Coverings Res/Textile

Vinyl Tiles (Under Floor Covering/Carpet)

3882/B00A/R0004/Floor Coverings Res/Textile/S10

33m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00A - R0007 - Principal

Floor Coverings Res/Textile

Vinyl Tiles (Under Floor Covering/Carpet)

3882/B00A/R0004/Floor Coverings Res/Textile/S10

21m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00A - R0008 - Staff Toilet

No Asbestos

B00A - R0009 - Cleaning Distributed Store

No Asbestos

B00A - R0010 - Staff Toilet

Register Issue Date : Thursday, 23 Mar 2017 Page 2 of 263882 - Tamworth South Public School

Page 3: (Hazardous Materials and Risk Assessment) · School : Tamworth South Public School (3882) Asbestos Register Region : New England State Electorate : Tamworth Local Government Area

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

Status

Sample No

ControlPriority

3882 Tamworth South Public School 2017

Test Result

No Asbestos

B00A - R0011 - Clerical Office/Workroom

Thermacon Heater Encapsulated Insulation material within unit

Assumed Asbestos - Encased in metal

2Unit Throughout Friable Asbestos (5) Low (1) Low Priority (2-3)

Safe. Encapsulated Insulation material within unit

Assumed Asbestos - 1956 safe. Asbestos material encased

1Unit Northeast Good Condition (1) Low (1) Low Priority (2-3)

B00A - R0012 - Distribution Board Note: No inspection of live electrical installation.

Floor Coverings Res/Textile

Vinyl Tiles

3882/B00A/R0004/Floor Coverings Res/Textile/S10

0.45m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

Wall Linings Internal Flat AC Sheeting

3882/B00E/R0005/Wall Linings Internal/S3

3m2 West Good Condition (1) Low (1)

Chrysotile (white asbestos) , Amosite (brown

asbestos)

Low Priority (2-3)

B00A - R0013 - Home Base

Thermacon Heater Encapsulated Insulation material within unit

Assumed Asbestos - Encased in metal

3Unit Throughout Friable Asbestos (5) Low (1) Low Priority (2-3)

Floor Coverings Res/Textile

Vinyl Tiles (Under Floor Covering/Carpet)

3882/B00A/R0004/Floor Coverings Res/Textile/S10

NA Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00A - R0014 - Home Base Store

Floor Coverings Res/Textile

Vinyl Tiles (Under Floor Covering/Carpet)

3882/B00A/R0004/Floor Coverings Res/Textile/S10

4m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00A - R0015 - Practical Activities - 1hb

Floor Coverings Res/Textile

Vinyl Tiles

3882/B00E/R0005/Floor Coverings Res/Textile/S4

19m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00A - R0016 - Home Base

Thermacon Heater Encapsulated Insulation material within unit

Assumed Asbestos - Encased in metal

3Unit Throughout Friable Asbestos (5) Low (1) Low Priority (2-3)

Floor Coverings Res/Textile

Vinyl Tiles (Under Floor Covering/Carpet)

3882/B00A/R0004/Floor Coverings Res/Textile/S10

57m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00A - R0017 - Home Base Store

Floor Coverings Res/Textile

Vinyl Tiles (Under Floor Covering/Carpet)

3882/B00A/R0004/Floor Coverings Res/Textile/S10

4m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00A - R0018 - Home Base

Thermacon Heater Encapsulated Insulation material within unit

Assumed Asbestos - Encased in metal

3Unit Throughout Friable Asbestos (5) Low (1) Low Priority (2-3)

Floor Coverings Res/Textile

Vinyl Tiles (Under Floor Covering/Carpet)

3882/B00A/R0004/Floor Coverings Res/Textile/S10

57m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00A - R0019 - Home Base Store

Floor Coverings Res/Textile

Vinyl Tiles (Under Floor Covering/Carpet)

3882/B00A/R0004/Floor Coverings Res/Textile/S10

4m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00A - R0020 - Practical Activities - 1hb

No Asbestos

Register Issue Date : Thursday, 23 Mar 2017 Page 3 of 263882 - Tamworth South Public School

Page 4: (Hazardous Materials and Risk Assessment) · School : Tamworth South Public School (3882) Asbestos Register Region : New England State Electorate : Tamworth Local Government Area

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

Status

Sample No

ControlPriority

3882 Tamworth South Public School 2017

Test Result

B00B - Library - 1956 - Timber (Timber)

Exterior

Eaves Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

20m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

Underfloor Voids Non Accessible Area

- No door & inadequate head space.

Ceiling Voids Non Accessible Area

- Height restricted.

Interior

B00B - R0005 - K.L.A. Store

Floor Coverings Res/Textile

Vinyl Tiles

3882/B00B/R0005/Floor Coverings Res/Textile/S18 No Asbestos Detected

Floor Coverings Res/Textile

Red tile adhesive/underlay

3882/B00B/R0005/Floor Coverings Res/Textile/S19 No Asbestos Detected

B00B - R0009 - Distribution Board Note: No inspection of live electrical installation.

Electrical Mounting Board Resinous Board

Assumed Asbestos - Live.

1Unit East Good Condition (1) Low (1) Low Priority (2-3)

B00B - R0010 - Reading Area

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

25m2 Northeast Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00B - R0011 - Library Office/Workroom

No Asbestos

B00B - R0012 - Communications Room

No Asbestos

B00B - R0013 - Movement

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

8m2 Northeast Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00B - R0014 - Special Programs Store

No Asbestos

B00B - R0015 - Movement

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

2m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00B - R0016 - Special Programs Room

No Asbestos

Register Issue Date : Thursday, 23 Mar 2017 Page 4 of 263882 - Tamworth South Public School

Page 5: (Hazardous Materials and Risk Assessment) · School : Tamworth South Public School (3882) Asbestos Register Region : New England State Electorate : Tamworth Local Government Area

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

Status

Sample No

ControlPriority

3882 Tamworth South Public School 2017

Test Result

B00C - General Learning/Pupil Facilities - 1956 - Timber (Timber)

Exterior

Eaves Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

40m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

Ceiling Voids Non Accessible Area

- No manhole sighted.

Underfloor Voids No Asbestos Found

Interior

B00C - R0001 - Craft Store

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

7m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00C - R0002 - Home Base

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

54m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

Floor Coverings Res/Textile

Vinyl Tiles (Under Floor Covering/Carpet)

3882/B00G/R0004/Floor Coverings Res/Textile/S12 No Asbestos Detected

B00C - R0003 - Home Base

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

53.58m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

Floor Coverings Res/Textile

Vinyl Tiles (Under Floor Covering/Carpet)

3882/B00G/R0004/Floor Coverings Res/Textile/S12 No Asbestos Detected

B00C - R0004 - Practical Activities - 1hb

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

28m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00C - R0005 - Clerical Office/Workroom

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

22.4m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

Floor Coverings Res/Textile

Vinyl Tiles (Under Floor Covering/Carpet)

3882/B00G/R0004/Floor Coverings Res/Textile/S12 No Asbestos Detected

B00C - R0006 - Home Base

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

53.58m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

Floor Coverings Res/Textile

Vinyl Tiles (Under Floor Covering/Carpet)

3882/B00G/R0004/Floor Coverings Res/Textile/S12 No Asbestos Detected

B00C - R0007 - Practical Activities - 1hb

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

25m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00C - R0008 - Home Base

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

54m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

Floor Coverings Res/Textile

Vinyl Tiles (Under Floor Covering/Carpet)

3882/B00G/R0004/Floor Coverings Res/Textile/S12 No Asbestos Detected

B00C - R0009 - Practical Activities - 1hb

Register Issue Date : Thursday, 23 Mar 2017 Page 5 of 263882 - Tamworth South Public School

Page 6: (Hazardous Materials and Risk Assessment) · School : Tamworth South Public School (3882) Asbestos Register Region : New England State Electorate : Tamworth Local Government Area

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

Status

Sample No

ControlPriority

3882 Tamworth South Public School 2017

Test Result

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

18m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00C - R0010 - Home Base Store

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

13m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00C - R0011 - General Storeroom

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

10m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

Electrical Mounting Board Resinous Board

Assumed Asbestos - Live.

1Unit West Good Condition (1) Low (1) Low Priority (2-3)

B00C - R0012 - Movement

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

10m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00C - R0013 - Home Base

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

53.58m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

Floor Coverings Res/Textile

Vinyl Tiles (Under Floor Covering/Carpet)

3882/B00G/R0004/Floor Coverings Res/Textile/S12 No Asbestos Detected

B00C - R0014 - Practical Activities - 1hb

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

17m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00C - R0015 - Home Base

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

53.58m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

Floor Coverings Res/Textile

Vinyl Tiles (Under Floor Covering/Carpet)

3882/B00G/R0004/Floor Coverings Res/Textile/S12 No Asbestos Detected

B00C - R0016 - Practical Activities - 1hb

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

18m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00C - R0017 - Toilets - Boys

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

14m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

Wall Linings Internal Flat AC Sheeting

3882/B00C/R0017/Wall Linings Internal/S1 No Asbestos Detected

B00C - R0018 - Toilets - Girls

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

10m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

Wall Linings Internal Flat AC Sheeting

3882/B00C/R0017/Wall Linings Internal/S1 No Asbestos Detected

B00C - R0019 - Cleaning Distributed Store

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

4m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

Wall Linings Internal Flat AC Sheeting

3882/B00C/R0017/Wall Linings Internal/S1 No Asbestos Detected

Register Issue Date : Thursday, 23 Mar 2017 Page 6 of 263882 - Tamworth South Public School

Page 7: (Hazardous Materials and Risk Assessment) · School : Tamworth South Public School (3882) Asbestos Register Region : New England State Electorate : Tamworth Local Government Area

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

Status

Sample No

ControlPriority

3882 Tamworth South Public School 2017

Test Result

B00C - R0020 - Movement

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

1m2 South Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00C - R0021 - Movement

No Asbestos

B00C - R0022 - Movement

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

1m2 South Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00C - R0023 - Movement

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

1m2 South Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

Register Issue Date : Thursday, 23 Mar 2017 Page 7 of 263882 - Tamworth South Public School

Page 8: (Hazardous Materials and Risk Assessment) · School : Tamworth South Public School (3882) Asbestos Register Region : New England State Electorate : Tamworth Local Government Area

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

Status

Sample No

ControlPriority

3882 Tamworth South Public School 2017

Test Result

B00D - Staff Facilities/General Learning - 1961 - Timber (Timber)

Exterior

Eaves Linings Flat AC Sheeting

3882/B00D/Eaves Linings/S20

40m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos) , Amosite (brown

asbestos)

Low Priority (2-3)

Ceiling Voids Non Accessible Area

- No manhole.

Underfloor Voids No Asbestos Found

Interior

B00D - R0001 - General Storeroom

No Asbestos

B00D - R0002 - General Storeroom

No Asbestos

B00D - R0003 - Craft Store

No Asbestos

B00D - R0004 - Staff Room

Electrical Mounting Board Resinous Board

Assumed Asbestos - Equipment live

1Unit West Good Condition (1) Low (1) Low Priority (2-3)

Floor Coverings Res/Textile

Vinyl Tiles (Under Floor Covering/Carpet)

3882/B00D/R0015/Floor Coverings Res/Textile/S21 No Asbestos Detected

Floor Coverings Res/Textile

Adhesive/underlay vinyl tiles under carpet

3882/B00D/R0015/Floor Coverings Res/Textile/S22 No Asbestos Detected

B00D - R0005 - Movement

No Asbestos

B00D - R0006 - Movement

Ceiling Structures/Linings Flat AC Sheeting

3882/B00D/Eaves Linings/S20

1m2 South Good Condition (1) Low (1)

Chrysotile (white asbestos) , Amosite (brown

asbestos)

Low Priority (2-3)

B00D - R0007 - Staff Room Annexe

Floor Coverings Res/Textile

Vinyl Tiles (Under Floor Covering/Carpet)

3882/B00D/R0015/Floor Coverings Res/Textile/S21 No Asbestos Detected

Floor Coverings Res/Textile

Adhesive/underlay vinyl tiles under carpet

3882/B00D/R0015/Floor Coverings Res/Textile/S22 No Asbestos Detected

B00D - R0008 - Practical Activities - 1hb

No Asbestos

B00D - R0009 - Movement

No Asbestos

B00D - R0010 - Movement

Ceiling Structures/Linings Flat AC Sheeting

3882/B00D/Eaves Linings/S20

1m2 South Good Condition (1) Low (1)

Chrysotile (white asbestos) , Amosite (brown

asbestos)

Low Priority (2-3)

B00D - R0011 - Withdrawal Space - 1hb

Floor Coverings Res/Textile

Vinyl Tiles (Under Floor Covering/Carpet)

3882/B00D/R0015/Floor Coverings Res/Textile/S21 No Asbestos Detected

Floor Coverings Res/Textile

Adhesive/underlay vinyl tiles under carpet

3882/B00D/R0015/Floor Coverings Res/Textile/S22 No Asbestos Detected

Register Issue Date : Thursday, 23 Mar 2017 Page 8 of 263882 - Tamworth South Public School

Page 9: (Hazardous Materials and Risk Assessment) · School : Tamworth South Public School (3882) Asbestos Register Region : New England State Electorate : Tamworth Local Government Area

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

Status

Sample No

ControlPriority

3882 Tamworth South Public School 2017

Test Result

B00D - R0012 - Home Base

Floor Coverings Res/Textile

Vinyl Tiles (Under Floor Covering/Carpet)

3882/B00D/R0015/Floor Coverings Res/Textile/S21 No Asbestos Detected

Floor Coverings Res/Textile

Adhesive/underlay vinyl tiles under carpet

3882/B00D/R0015/Floor Coverings Res/Textile/S22 No Asbestos Detected

B00D - R0013 - Practical Activities - 1hb

No Asbestos

B00D - R0014 - Home Base Store

Floor Coverings Res/Textile

Vinyl Tiles (Under Floor Covering/Carpet)

3882/B00D/R0015/Floor Coverings Res/Textile/S21 No Asbestos Detected

Floor Coverings Res/Textile

Adhesive/underlay vinyl tiles under carpet

3882/B00D/R0015/Floor Coverings Res/Textile/S22 No Asbestos Detected

B00D - R0015 - Withdrawal Space - 2hb

Electrical Mounting Board Resinous Board

Assumed Asbestos - Live.

1Unit West Good Condition (1) Low (1) Low Priority (2-3)

Floor Coverings Res/Textile

Vinyl Tiles (Under Floor Covering/Carpet)

3882/B00D/R0015/Floor Coverings Res/Textile/S21 No Asbestos Detected

Floor Coverings Res/Textile

Adhesive/underlay vinyl tiles under carpet

3882/B00D/R0015/Floor Coverings Res/Textile/S22 No Asbestos Detected

B00D - R0016 - Movement

Ceiling Structures/Linings Flat AC Sheeting

3882/B00D/Eaves Linings/S20

1m2 South Good Condition (1) Low (1)

Chrysotile (white asbestos) , Amosite (brown

asbestos)

Low Priority (2-3)

B00D - R0017 - Home Base

Floor Coverings Res/Textile

Vinyl Tiles (Under Floor Covering/Carpet)

3882/B00D/R0015/Floor Coverings Res/Textile/S21 No Asbestos Detected

Floor Coverings Res/Textile

Adhesive/underlay vinyl tiles under carpet

3882/B00D/R0015/Floor Coverings Res/Textile/S22 No Asbestos Detected

B00D - R0018 - Practical Activities - 1hb

No Asbestos

B00D - R0019 - Home Base

Floor Coverings Res/Textile

Vinyl Tiles (Under Floor Covering/Carpet)

3882/B00D/R0015/Floor Coverings Res/Textile/S21 No Asbestos Detected

Floor Coverings Res/Textile

Adhesive/underlay vinyl tiles under carpet

3882/B00D/R0015/Floor Coverings Res/Textile/S22 No Asbestos Detected

B00D - R0020 - Practical Activities - 1hb

No Asbestos

B00D - R0021 - Movement

Ceiling Structures/Linings Flat AC Sheeting

3882/B00D/Eaves Linings/S20

1m2 South Good Condition (1) Low (1)

Chrysotile (white asbestos) , Amosite (brown

asbestos)

Low Priority (2-3)

Register Issue Date : Thursday, 23 Mar 2017 Page 9 of 263882 - Tamworth South Public School

Page 10: (Hazardous Materials and Risk Assessment) · School : Tamworth South Public School (3882) Asbestos Register Region : New England State Electorate : Tamworth Local Government Area

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

Status

Sample No

ControlPriority

3882 Tamworth South Public School 2017

Test Result

B00E - General Learning/Pupil Facilities - 1956 - Brick/Veneer (Brick/Veneer)

Exterior

Eaves Linings Flat AC Sheeting

3882/B00E/Wall Cladding/S2 No Asbestos Detected

Gable Verge Lining Flat AC Sheeting

3882/B00A/Gable Verge Lining/S17

16m2 East, West Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

Wall Cladding Flat AC Sheeting

3882/B00E/Wall Cladding/S2 No Asbestos Detected

Ceiling Voids Ceiling lining assume asbestos refer to S23. No ACM debris sighted.

3882/B00E/R0016/Ceiling Structures/Linings/S23 No Asbestos Detected

Underfloor Voids - Slab on Ground

No Asbestos Found

In-fill panels Flat AC Sheeting

3882/B00A/R0001/Below window in-fill panels./S16

20m2 South Good Condition (1) Low (1)

Chrysotile (white asbestos) , Amosite (brown

asbestos)

Low Priority (2-3)

Gable Ends Flat AC Sheeting

3882/B00E/Gable Ends/S24 No Asbestos Detected

Interior

B00E - R0001 - Movement

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

96m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00E - R0002 - Deputy Principal

Thermacon Heater Encapsulated Insulation material within unit

Assumed Asbestos - Encased in metal

1Unit Throughout Friable Asbestos (5) Low (1) Low Priority (2-3)

B00E - R0003 - General Storeroom

Floor Coverings Res/Textile

Vinyl Tiles

3882/B00E/R0005/Floor Coverings Res/Textile/S4

7.09m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00E - R0004 - Staff Toilet

No Asbestos

B00E - R0005 - Distribution Board Note: No inspection of live electrical installation.

Wall Linings Internal Flat AC Sheeting

3882/B00E/R0005/Wall Linings Internal/S3

6m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos) , Amosite (brown

asbestos)

Low Priority (2-3)

Floor Coverings Res/Textile

Vinyl Tiles

3882/B00E/R0005/Floor Coverings Res/Textile/S4

2m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00E - R0006 - Practical Activities - 1hb

No Asbestos

B00E - R0007 - Home Base Store

Floor Coverings Res/Textile

Vinyl Tiles

3882/B00E/R0005/Floor Coverings Res/Textile/S4

6m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00E - R0008 - Toilets - Boys/Girls

No Asbestos

B00E - R0009 - Home Base

Thermacon Heater Encapsulated Insulation material within unit

Assumed Asbestos - Encased in metal

5Unit Throughout Friable Asbestos (5) Low (1) Low Priority (2-3)

Register Issue Date : Thursday, 23 Mar 2017 Page 10 of 263882 - Tamworth South Public School

Page 11: (Hazardous Materials and Risk Assessment) · School : Tamworth South Public School (3882) Asbestos Register Region : New England State Electorate : Tamworth Local Government Area

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

Status

Sample No

ControlPriority

3882 Tamworth South Public School 2017

Test Result

Floor Coverings Res/Textile

Vinyl Tiles (Under Floor Covering/Carpet)

3882/B00E/R0005/Floor Coverings Res/Textile/S4

85.17m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00E - R0010 - Home Base

Thermacon Heater Encapsulated Insulation material within unit

Assumed Asbestos - Encased in metal

4Unit Throughout Friable Asbestos (5) Low (1) Low Priority (2-3)

Floor Coverings Res/Textile

Vinyl Tiles (Under Floor Covering/Carpet)

3882/B00E/R0005/Floor Coverings Res/Textile/S4

85.1m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00E - R0011 - Toilets - Boys/Girls

No Asbestos

B00E - R0012 - Home Base Store

Floor Coverings Res/Textile

Vinyl Tiles

3882/B00E/R0005/Floor Coverings Res/Textile/S4

4m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00E - R0013 - Practical Activities - 1hb

No Asbestos

B00E - R0014 - Home Base Store

Floor Coverings Res/Textile

Vinyl Tiles

3882/B00E/R0005/Floor Coverings Res/Textile/S4

4m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00E - R0015 - Home Base

Thermacon Heater Encapsulated Insulation material within unit

Assumed Asbestos - Encased in metal

3Unit Throughout Friable Asbestos (5) Low (1) Low Priority (2-3)

Floor Coverings Res/Textile

Vinyl Tiles (Under Floor Covering/Carpet)

3882/B00E/R0005/Floor Coverings Res/Textile/S4

56.89m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00E - R0016 - Toilets - Girls

Ceiling Structures/Linings Flat AC Sheeting

3882/B00E/R0016/Ceiling Structures/Linings/S23 No Asbestos Detected

B00E - R0017 - Toilets - Boys

Ceiling Structures/Linings Flat AC Sheeting

3882/B00E/R0016/Ceiling Structures/Linings/S23 No Asbestos Detected

B00E - R0018 - Disabled Toilet

No Asbestos

Register Issue Date : Thursday, 23 Mar 2017 Page 11 of 263882 - Tamworth South Public School

Page 12: (Hazardous Materials and Risk Assessment) · School : Tamworth South Public School (3882) Asbestos Register Region : New England State Electorate : Tamworth Local Government Area

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

Status

Sample No

ControlPriority

3882 Tamworth South Public School 2017

Test Result

B00F - General Learning/Pupil Facilities - 1956 - Timber (Timber)

Exterior

Eaves Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

20m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

Ceiling Voids Non Accessible Area

- No manhole.

Underfloor Voids Flat AC fragment.

Assumed Asbestos - Fragment inaccessible through under

0.01m2 North Some Damage - Unsealed (3)

Low (1) Medium Priority (4-5)

Interior

B00F - R0001 - Home Base

No Asbestos

B00F - R0002 - Practical Activities - 1hb

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

14.42m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00F - R0003 - Toilets - Boys/Girls

No Asbestos

B00F - R0004 - Personal Effects Storage

No Asbestos

B00F - R0005 - Movement

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

28.19m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00F - R0006 - Personal Effects Storage

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

13.91m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00F - R0007 - Toilets - Boys/Girls

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

3.66m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00F - R0008 - Home Base

No Asbestos

B00F - R0009 - Home Base

No Asbestos

B00F - R0010 - Duplicating Workroom

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

13.18m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00F - R0011 - Practical Activities - 1hb

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

12.79m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00F - R0012 - Movement

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

15m2 North Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00F - R0013 - Movement

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

41.38m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

Register Issue Date : Thursday, 23 Mar 2017 Page 12 of 263882 - Tamworth South Public School

Page 13: (Hazardous Materials and Risk Assessment) · School : Tamworth South Public School (3882) Asbestos Register Region : New England State Electorate : Tamworth Local Government Area

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

Status

Sample No

ControlPriority

3882 Tamworth South Public School 2017

Test Result

B00G - General Learning - 1956 - Timber (Timber)

Exterior

Eaves Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

40m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

Ceiling Voids Non Accessible Area

- No manhole.

Underfloor Voids No Asbestos Found

Interior

B00G - R0001 - Practical Activities - 1hb

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

24m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00G - R0002 - Music Store

Floor Coverings Res/Textile

Vinyl Tiles

3882/B00G/R0004/Floor Coverings Res/Textile/S12 No Asbestos Detected

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

6m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00G - R0003 - Interview

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

14m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00G - R0004 - Movement

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

4m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

Floor Coverings Res/Textile

Vinyl Tiles (Under Floor Covering/Carpet)

3882/B00G/R0004/Floor Coverings Res/Textile/S12 No Asbestos Detected

B00G - R0005 - Home Base

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

53.58m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00G - R0006 - Movement

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

1m2 Southeast Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00G - R0007 - Home Base

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

53.59m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00G - R0008 - Practical Activities - 1hb

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

17m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00G - R0009 - Home Base Store

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

12.63m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00G - R0010 - Home Base Store

Electrical Mounting Board Resinous Board

Assumed Asbestos - Live.

1Unit West Good Condition (1) Low (1) Low Priority (2-3)

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

9.37m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

Register Issue Date : Thursday, 23 Mar 2017 Page 13 of 263882 - Tamworth South Public School

Page 14: (Hazardous Materials and Risk Assessment) · School : Tamworth South Public School (3882) Asbestos Register Region : New England State Electorate : Tamworth Local Government Area

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

Status

Sample No

ControlPriority

3882 Tamworth South Public School 2017

Test Result

B00G - R0011 - Movement

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

9.3m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00G - R0012 - Movement

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

1m2 Southeast Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00G - R0013 - Home Base

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

53.59m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00G - R0014 - Practical Activities - 1hb

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

17m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00G - R0015 - Home Base

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

53.58m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00G - R0016 - Practical Activities - 1hb

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

24m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00G - R0017 - Craft Store

Floor Coverings Res/Textile

Vinyl Tiles

3882/B00G/R0004/Floor Coverings Res/Textile/S12 No Asbestos Detected

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

5.62m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00G - R0018 - General Storeroom

Floor Coverings Res/Textile

Vinyl Tiles

3882/B00G/R0004/Floor Coverings Res/Textile/S12 No Asbestos Detected

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

16.38m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00G - R0019 - Movement

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

1m2 Southeast Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

Register Issue Date : Thursday, 23 Mar 2017 Page 14 of 263882 - Tamworth South Public School

Page 15: (Hazardous Materials and Risk Assessment) · School : Tamworth South Public School (3882) Asbestos Register Region : New England State Electorate : Tamworth Local Government Area

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

Status

Sample No

ControlPriority

3882 Tamworth South Public School 2017

Test Result

B00H - Support Unit - 1984 - Timber (Timber)

Exterior

Eaves Linings Flat AC Sheeting

3882/B00H/R0007/Ceiling Structures/Linings/S14

12m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

Ceiling Voids No Asbestos Found

Underfloor Voids No Asbestos Found

Interior

B00H - R0003 - Home Base - E

Floor Coverings Res/Textile

Vinyl Tiles (Under Floor Covering/Carpet)

3882/B00A/R0004/Floor Coverings Res/Textile/S10

53.58m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00H - R0005 - Movement

Ceiling Structures/Linings Flat AC Sheeting

3882/B00H/R0007/Ceiling Structures/Linings/S14

1m2 Southeast Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00H - R0006 - Therapy

Floor Coverings Res/Textile

Vinyl Tiles (Under Floor Covering/Carpet)

3882/B00A/R0004/Floor Coverings Res/Textile/S10

53.59m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00H - R0007 - Practical Activities - 1hb

Ceiling Structures/Linings Flat AC Sheeting

3882/B00H/R0007/Ceiling Structures/Linings/S14

18m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

Floor Coverings Res/Textile

Vinyl Tiles (Under Floor Covering/Carpet)

3882/B00H/R0007/Floor Coverings Res/Textile/S15 No Asbestos Detected

B00H - R0008 - Home Base Store

Floor Coverings Res/Textile

Vinyl Tiles (Under Floor Covering/Carpet)

3882/B00A/R0004/Floor Coverings Res/Textile/S10

12.66m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00H - R0009 - Home Base Store

Electrical Mounting Board Resinous Board

Assumed Asbestos - Live.

1Unit Southwest Good Condition (1) Low (1) Low Priority (2-3)

Floor Coverings Res/Textile

Vinyl Tiles (Under Floor Covering/Carpet)

3882/B00A/R0004/Floor Coverings Res/Textile/S10

9.3m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00H - R0010 - Movement

Ceiling Structures/Linings Flat AC Sheeting

3882/B00H/R0007/Ceiling Structures/Linings/S14

10m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

Floor Coverings Res/Textile

Vinyl Tiles (Under Floor Covering/Carpet)

3882/B00H/R0007/Floor Coverings Res/Textile/S15 No Asbestos Detected

B00H - R0011 - Movement

Ceiling Structures/Linings Flat AC Sheeting

3882/B00H/R0007/Ceiling Structures/Linings/S14

1m2 Southeast Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00H - R0012 - Home Base - M

Floor Coverings Res/Textile

Vinyl Tiles (Under Floor Covering/Carpet)

3882/B00A/R0004/Floor Coverings Res/Textile/S10

53.59m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00H - R0013 - Practical Activities - M - 1hb

Ceiling Structures/Linings Flat AC Sheeting

3882/B00H/R0007/Ceiling Structures/Linings/S14

16m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

Register Issue Date : Thursday, 23 Mar 2017 Page 15 of 263882 - Tamworth South Public School

Page 16: (Hazardous Materials and Risk Assessment) · School : Tamworth South Public School (3882) Asbestos Register Region : New England State Electorate : Tamworth Local Government Area

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

Status

Sample No

ControlPriority

3882 Tamworth South Public School 2017

Test Result

Floor Coverings Res/Textile

Vinyl Tiles (Under Floor Covering/Carpet)

3882/B00A/R0004/Floor Coverings Res/Textile/S10

10m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00H - R0014 - Home Base - M

No Asbestos

B00H - R0015 - Practical Activities - M - 1hb

Ceiling Structures/Linings Flat AC Sheeting

3882/B00H/R0007/Ceiling Structures/Linings/S14

4m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

Floor Coverings Res/Textile

Vinyl Tiles (Under Floor Covering/Carpet)

3882/B00H/R0007/Floor Coverings Res/Textile/S15 No Asbestos Detected

B00H - R0016 - Laundry - Type 2

No Asbestos

B00H - R0017 - Toilet - M

No Asbestos

B00H - R0018 - Movement

Ceiling Structures/Linings Flat AC Sheeting

3882/B00H/R0007/Ceiling Structures/Linings/S14

1m2 Southeast Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00H - R0019 - Practical Activities - M - 1hb

Ceiling Structures/Linings Flat AC Sheeting

3882/B00H/R0007/Ceiling Structures/Linings/S14

17m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

Floor Coverings Res/Textile

Vinyl Tiles (Under Floor Covering/Carpet)

3882/B00A/R0004/Floor Coverings Res/Textile/S10

16.81m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00H - R0020 - Toilet - M

No Asbestos

B00H - R0021 - Other

Floor Coverings Res/Textile

Vinyl Tiles (Under Floor Covering/Carpet)

3882/B00A/R0004/Floor Coverings Res/Textile/S10

5.85m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00H - R0022 - Clerical/Printing

Floor Coverings Res/Textile

Vinyl Tiles (Under Floor Covering/Carpet)

3882/B00A/R0004/Floor Coverings Res/Textile/S10

16.31m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

Register Issue Date : Thursday, 23 Mar 2017 Page 16 of 263882 - Tamworth South Public School

Page 17: (Hazardous Materials and Risk Assessment) · School : Tamworth South Public School (3882) Asbestos Register Region : New England State Electorate : Tamworth Local Government Area

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

Status

Sample No

ControlPriority

3882 Tamworth South Public School 2017

Test Result

B00I - General Learning - 1968 - Timber (Timber)

Exterior

Eaves Linings Flat AC Sheeting

3882/B00I/Eaves Linings/S25

12m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos) , Amosite (brown

asbestos)

Low Priority (2-3)

Ceiling Voids Non Accessible Area

- No manhole.

Underfloor Voids No Asbestos Found

Interior

B00I - R0001 - General Storeroom

Ceiling Structures/Linings Flat AC Sheeting

3882/B00I/Eaves Linings/S25

3m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos) , Amosite (brown

asbestos)

Low Priority (2-3)

Floor Coverings Res/Textile

Vinyl Tiles

3882/B00I/R0001/Floor Coverings Res/Textile/S13

3m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00I - R0002 - Home Base

Ceiling Structures/Linings Flat AC Sheeting

3882/B00I/Eaves Linings/S25

53.59m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos) , Amosite (brown

asbestos)

Low Priority (2-3)

Floor Coverings Res/Textile

Vinyl Tiles (Under Floor Covering/Carpet)

3882/B00I/R0008/Floor Coverings Res/Textile/S26 No Asbestos Detected

Floor Coverings Res/Textile

Adhesive/underlay under dark green tile under carpe

3882/B00I/R0008/Floor Coverings Res/Textile/S27 No Asbestos Detected

B00I - R0003 - Movement

Ceiling Structures/Linings Flat AC Sheeting

3882/B00I/Eaves Linings/S25

13m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos) , Amosite (brown

asbestos)

Low Priority (2-3)

B00I - R0004 - Movement

Ceiling Structures/Linings Flat AC Sheeting

3882/B00I/Eaves Linings/S25

1m2 Southeast Good Condition (1) Low (1)

Chrysotile (white asbestos) , Amosite (brown

asbestos)

Low Priority (2-3)

B00I - R0005 - Practical Activities - 1hb

Ceiling Structures/Linings Flat AC Sheeting

3882/B00I/Eaves Linings/S25

4.05m2 Southeast Good Condition (1) Low (1)

Chrysotile (white asbestos) , Amosite (brown

asbestos)

Low Priority (2-3)

B00I - R0006 - Practical Activities - 1hb

Ceiling Structures/Linings Flat AC Sheeting

3882/B00I/Eaves Linings/S25

41.5m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos) , Amosite (brown

asbestos)

Low Priority (2-3)

Floor Coverings Res/Textile

Adhesive/underlay under dark green tile under carpe

3882/B00I/R0008/Floor Coverings Res/Textile/S27 No Asbestos Detected

Floor Coverings Res/Textile

Vinyl Tiles (Under Floor Covering/Carpet)

3882/B00I/R0008/Floor Coverings Res/Textile/S26 No Asbestos Detected

B00I - R0007 - Withdrawal Space - 1hb

Ceiling Structures/Linings Flat AC Sheeting

3882/B00I/Eaves Linings/S25

7.19m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos) , Amosite (brown

asbestos)

Low Priority (2-3)

Register Issue Date : Thursday, 23 Mar 2017 Page 17 of 263882 - Tamworth South Public School

Page 18: (Hazardous Materials and Risk Assessment) · School : Tamworth South Public School (3882) Asbestos Register Region : New England State Electorate : Tamworth Local Government Area

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

Status

Sample No

ControlPriority

3882 Tamworth South Public School 2017

Test Result

Floor Coverings Res/Textile

Adhesive/underlay under dark green tile under carpe

3882/B00I/R0008/Floor Coverings Res/Textile/S27 No Asbestos Detected

Floor Coverings Res/Textile

Vinyl Tiles (Under Floor Covering/Carpet)

3882/B00I/R0008/Floor Coverings Res/Textile/S26 No Asbestos Detected

B00I - R0008 - Movement

Ceiling Structures/Linings Flat AC Sheeting

3882/B00I/Eaves Linings/S25

16m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos) , Amosite (brown

asbestos)

Low Priority (2-3)

Floor Coverings Res/Textile

Vinyl Tiles (Under Floor Covering/Carpet)

3882/B00I/R0008/Floor Coverings Res/Textile/S26 No Asbestos Detected

Floor Coverings Res/Textile

Adhesive/underlay under dark green tile under carpe

3882/B00I/R0008/Floor Coverings Res/Textile/S27 No Asbestos Detected

B00I - R0009 - Movement

Ceiling Structures/Linings Flat AC Sheeting

3882/B00I/Eaves Linings/S25

1m2 Southeast Good Condition (1) Low (1)

Chrysotile (white asbestos) , Amosite (brown

asbestos)

Low Priority (2-3)

Register Issue Date : Thursday, 23 Mar 2017 Page 18 of 263882 - Tamworth South Public School

Page 19: (Hazardous Materials and Risk Assessment) · School : Tamworth South Public School (3882) Asbestos Register Region : New England State Electorate : Tamworth Local Government Area

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

Status

Sample No

ControlPriority

3882 Tamworth South Public School 2017

Test Result

B00J - Shed - 1970 - Timber (Timber)

Exterior

Eaves Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

20m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

Underfloor Voids - Slab on Ground

No Asbestos Found

Ceiling Voids No Asbestos Found

Interior

B00J - R0001 - Movement

Ceiling Structures/Linings Flat AC Sheeting

3882/B00A/R0001/Ceiling Structures/Linings/S8

12m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00J - R0002 - General Storeroom

Floor Coverings Res/Textile

Vinyl Tiles

3882/B00G/R0004/Floor Coverings Res/Textile/S12 No Asbestos Detected

B00J - R0003 - General Storeroom

Floor Coverings Res/Textile

Vinyl Tiles

3882/B00G/R0004/Floor Coverings Res/Textile/S12 No Asbestos Detected

Electrical Mounting Board Resinous Board

Assumed Asbestos - Live.

1Unit East Good Condition (1) Low (1) Low Priority (2-3)

B00J - R0004 - General Storeroom

Floor Coverings Res/Textile

Vinyl Tiles

3882/B00G/R0004/Floor Coverings Res/Textile/S12 No Asbestos Detected

Register Issue Date : Thursday, 23 Mar 2017 Page 19 of 263882 - Tamworth South Public School

Page 20: (Hazardous Materials and Risk Assessment) · School : Tamworth South Public School (3882) Asbestos Register Region : New England State Electorate : Tamworth Local Government Area

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

Status

Sample No

ControlPriority

3882 Tamworth South Public School 2017

Test Result

B00K - General Learning/Pupil Facilities - 1956 - Brick/Veneer (Brick/Veneer)

Exterior

Underfloor Voids - Slab on Ground

No Asbestos Found

Ceiling Voids No Asbestos Found

Interior

B00K - R0001 - Movement

Wall cladding Flat AC Sheeting

3882/B00K/R0001/Wall cladding/S6 No Asbestos Detected

B00K - R0002 - Canteen

No Asbestos

B00K - R0003 - Canteen Office/Store

No Asbestos

B00K - R0004 - Canteen Office/Store

Electrical Mounting Board Resinous Board

Assumed Asbestos - Live

1Unit Southwest Good Condition (1) Low (1) Low Priority (2-3)

B00K - R0005 - P.E. Store

No Asbestos

B00K - R0006 - Disabled Toilet

No Asbestos

B00K - R0007 - Sports Store

No Asbestos

B00K - R0010 - Hall Chair Store

No Asbestos

B00K - R0011 - Music Store

No Asbestos

B00K - R0013 - Toilets - Girls

Partition Walls (Cubicles) Compressed AC Sheet

3882/B00K/R0014/Partition Walls (Cubicles)/S7

6m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00K - R0014 - Shower/Change

Partition Walls (Cubicles) Compressed AC Sheet

3882/B00K/R0014/Partition Walls (Cubicles)/S7

2m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00K - R0015 - Cleaning Distributed Store

No Asbestos

B00K - R0016 - Movement

No Asbestos

B00K - R0018 - Movement

No Asbestos

B00K - R0019 - Shower/Change

No Asbestos

B00K - R0020 - Toilets - Boys

No Asbestos

B00K - R0021 - Distribution Board Note: No inspection of live electrical installation.

Electrical Mounting Board Resinous Board

Assumed Asbestos - Live.

1Unit Northwest Good Condition (1) Low (1) Low Priority (2-3)

B00K - R0022 - External Movement

No Asbestos Found

B00K - R0023 - External Movement

No Asbestos Found

Register Issue Date : Thursday, 23 Mar 2017 Page 20 of 263882 - Tamworth South Public School

Page 21: (Hazardous Materials and Risk Assessment) · School : Tamworth South Public School (3882) Asbestos Register Region : New England State Electorate : Tamworth Local Government Area

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

Status

Sample No

ControlPriority

3882 Tamworth South Public School 2017

Test Result

B00K - R0024 - External Movement

No Asbestos Found

B00K - R0025 - Special Programs Room

No Asbestos Found

B00K - R0026 - Withdrawal Space - 1hb

No Asbestos Found

B00K - R0027 - Home Base

No Asbestos Found

B00K - R0028 - Practical Activities/Movement - 1hb

No Asbestos Found

B00K - R0029 - Home Base

No Asbestos Found

B00K - R0030 - No Access

No Asbestos Found

B00K - R0031 - Special Programs Room

No Asbestos Found

Register Issue Date : Thursday, 23 Mar 2017 Page 21 of 263882 - Tamworth South Public School

Page 22: (Hazardous Materials and Risk Assessment) · School : Tamworth South Public School (3882) Asbestos Register Region : New England State Electorate : Tamworth Local Government Area

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

Status

Sample No

ControlPriority

3882 Tamworth South Public School 2017

Test Result

B00L - Pupil Facilities - 1970 - Brick/Block (Brick/Block)

Exterior

Eaves Linings Flat AC Sheeting

3882/B00L/Eaves Linings/S28

15m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

Ceiling Voids Non Accessible Area

- No manhole.

Underfloor Voids - Slab on Ground

No Asbestos Found

Interior

B00L - R0001 - Toilets - Girls

Ceiling Structures/Linings Flat AC Sheeting

3882/B00L/Eaves Linings/S28

32m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

Partition Walls (Cubicles) Compressed AC Sheet

3882/B00L/R0001/Partition Walls (Cubicles)/S5

8m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00L - R0002 - Toilets - Boys

Ceiling Structures/Linings Flat AC Sheeting

3882/B00L/Eaves Linings/S28

26m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

Partition Walls (Cubicles) Compressed AC Sheet

3882/B00L/R0001/Partition Walls (Cubicles)/S5

4m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

Register Issue Date : Thursday, 23 Mar 2017 Page 22 of 263882 - Tamworth South Public School

Page 23: (Hazardous Materials and Risk Assessment) · School : Tamworth South Public School (3882) Asbestos Register Region : New England State Electorate : Tamworth Local Government Area

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

Status

Sample No

ControlPriority

3882 Tamworth South Public School 2017

Test Result

B00M - Communal Facilities - 2011 - Brick/Veneer (Brick/Veneer)

Exterior

Ceiling Voids - Raked Ceiling

No Asbestos Found

Underfloor Voids - Slab on Ground

No Asbestos Found

Interior

B00M - R0001 - Communal Space

No Asbestos Found

B00M - R0002 - Raised Platform

No Asbestos Found

B00M - R0003 - Hall Chair Store

No Asbestos Found

B00M - R0004 - Communal/Performance Store

No Asbestos Found

B00M - R0005 - P.E. Store

No Asbestos Found

B00M - R0006 - Toilet - Lobby

No Asbestos Found

B00M - R0007 - Toilets - Girls

No Asbestos Found

B00M - R0008 - Sound Cupboard

No Asbestos Found

B00M - R0009 - Toilet - Lobby

No Asbestos Found

B00M - R0010 - Toilets - Boys

No Asbestos Found

B00M - R0011 - Cleaning Distributed Store

No Asbestos Found

B00M - R0012 - No Access

No Asbestos Found

B00M - R0013 - No Access

No Asbestos Found

B00M - R0014 - No Access

No Asbestos Found

B00M - R0015 - Covered Outdoor Learning Area

No Asbestos Found

B00M - R0016 - Movement

No Asbestos Found

B00M - R0017 - Ramp

No Asbestos Found

B00M - R0018 - Movement

No Asbestos Found

Register Issue Date : Thursday, 23 Mar 2017 Page 23 of 263882 - Tamworth South Public School

Page 24: (Hazardous Materials and Risk Assessment) · School : Tamworth South Public School (3882) Asbestos Register Region : New England State Electorate : Tamworth Local Government Area

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

Status

Sample No

ControlPriority

3882 Tamworth South Public School 2017

Test Result

Demountables

Demountable details as per the AMS records as of 15 Feb 2017.

OS 601 - D10755 - Learning Unit - Standard/Withdrawal : Placement Date - 16/03/2005

Exterior

Step Treads Compressed AC Sheet Assumed Asbestos 1.08 m2

Landing Compressed AC Sheet Assumed Asbestos 1.2 m2

Eave Lining Flat AC Sheet Assumed Asbestos 11.52 m2

Interior

R1 - Entry

End wall panel Flat AC Sheet Assumed Asbestos 18 m2

Ceiling Flat AC Sheet Assumed Asbestos 8 m2

R2 - General Learning Space

End wall panel Flat AC Sheet Assumed Asbestos 18 m2

Ceiling Flat AC Sheet Assumed Asbestos 55 m2

R3 - Store

Ceiling Flat AC Sheet Assumed Asbestos 10 m2

OS 602 - D11109 - Learning Unit - Standard With P.A.A. : Placement Date - 25/01/2010

Note: This refurbished demountable may have asbestos present in remnant mastic in window frames.

Exterior

No Asbestos Found.

Interior

R1 - Learning space/withdrawal/entry

No Asbestos Found.

R2 - Home Base Store

No Asbestos Found.

OS 602 - D12761 - Learning Unit - Standard With P.A.A. : Placement Date - 14/04/2010

Note: This refurbished demountable may have asbestos present in remnant mastic in window frames.

Exterior

No Asbestos Found.

Interior

R1 - Learning space/withdrawal/entry

No Asbestos Found.

R2 - Home Base Store

No Asbestos Found.

OS 601 - D13013 - Learning Unit - Standard/Withdrawal : Placement Date - 25/01/2010

Exterior

Step Treads Compressed AC Sheet Assumed Asbestos 1.08 m2

Landing Compressed AC Sheet Assumed Asbestos 1.2 m2

Eave Lining Flat AC Sheet Assumed Asbestos 11.52 m2

Register Issue Date : Thursday, 23 Mar 2017 Page 24 of 263882 - Tamworth South Public School

Page 25: (Hazardous Materials and Risk Assessment) · School : Tamworth South Public School (3882) Asbestos Register Region : New England State Electorate : Tamworth Local Government Area

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

Status

Sample No

ControlPriority

3882 Tamworth South Public School 2017

Test Result

Interior

R1 - Entry

End wall panel Flat AC Sheet Assumed Asbestos 18 m2

Ceiling Flat AC Sheet Assumed Asbestos 8 m2

R2 - General Learning Space

End wall panel Flat AC Sheet Assumed Asbestos 18 m2

Ceiling Flat AC Sheet Assumed Asbestos 55 m2

R3 - Store

Ceiling Flat AC Sheet Assumed Asbestos 10 m2

Register Issue Date : Thursday, 23 Mar 2017 Page 25 of 263882 - Tamworth South Public School

Page 26: (Hazardous Materials and Risk Assessment) · School : Tamworth South Public School (3882) Asbestos Register Region : New England State Electorate : Tamworth Local Government Area

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

Status

Sample No

ControlPriority

3882 Tamworth South Public School 2017

Test Result

Listing of Electronic Attachments as of 22/03/2017

There are no asbestos related file attachment(s) for this school.

Register Issue Date : Thursday, 23 Mar 2017 Page 26 of 263882 - Tamworth South Public School