Hazardous Locations Light-A0(و›²) - Patriot The unique light distribution design, light type and...

download Hazardous Locations Light-A0(و›²) - Patriot The unique light distribution design, light type and angle

of 58

  • date post

    09-Jun-2020
  • Category

    Documents

  • view

    0
  • download

    0

Embed Size (px)

Transcript of Hazardous Locations Light-A0(و›²) - Patriot The unique light distribution design, light type and...

  • Hazardous Locations Light

    www.patriotled.com I www.alg-usa.com

  • Hazardous

    Locations Light

    Products and solutions will

    Protect your business ...

    A Series

    E Series F Series

    I Series D2 Series

    S Series T Series

    C Series

    G Series

    EXIT K Series

    D Series

    H Series

    P Series

    IO 1Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com

  • Applications

    This luminaire can be used as spot light, down light

    and tunnel light which can provide general illumination

    in hazardous locations, such as:

    • Refinery factory

    • Oil and gasoline loading dock

    • Gas station

    • Painting manufacture workshop

    • Pumping station

    • Metal Smelting Plant

    • Mining

    • Ocean platform

    • Aerospace

    • Chemical plant

    • Vessel

    • Military

    • Flourmill

    • Distillerie

    • Power station

    • Other high humility, high temperature, dusty location ...

    Features

    • High efficacy: up to 140Im/W

    • CRl>70

    • Surface mounting and pendant installation

    • Wide and narrow optics for uniform illumination

    • Copper free aluminum

    • High vibration resistance

    Ratings and Certifications

    • NEMA 4X, IP66

    • UL 1598/U L 1598A/U L844

    • CSA C22.2 No.137/No.250.0

    Class I, Division 2, Groups A,B,C,D

    Class II, Division 1, Groups E,F,G

    Class II, Division 2, Groups E,F,G

    Class Ill

    • Marine and Wet Locations

    • IECEX

    • ATEX

    • 5 years or other warranty period specified in agreement

    • L70 rating for more than 150000 hours

    .... 1.

    lighting

    f!�!!" FC RoHS

    Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com

  • Typical Model Specification

    Product Number -- PT-40W AYZDA 40 4000K-5700K

    PT-SOW AYZDA 50 4000K-5700K

    PT-60W AYZDA 60 4000K-5700K

    PT-70WAYZDA 70 4000K-5700K

    PT-BOW AYZDA 80 4000K-5700K

    PT-90W AYZDA 90 4000K-5700K

    PT-1 OOW AYZDA 100 4000K-5700K

    PT-110WAYZDA 110 4000K-5700K

    PT-120W AYZDA 120 4000K-5700K

    Voltage Lumens

    AC 100-277V or AC200-480V 5600

    AC 100-277V or AC200-480V 7000

    AC 100-277V or AC200-480V 8400

    AC 100-277V or AC200-480V 9800

    AC 100-277V or AC200-480V 11200

    AC 100-277V or AC200-480V 12600

    AC 100-277V or AC200-480V 14000

    AC100-277V 15400

    AC100-277V 16800

    Working Hours

    5 years

    5 years

    5 years

    5 years

    5 years

    5 years

    5 years

    5 years

    5 years

    -- 70

    70

    70

    70

    70

    70

    70

    70

    70

    "A"=Product series "Y"=D or N:Dimmable or non-dimmable "Z"= CCT, from 4000-5700K "D"=Beam angle:40' ,60' ,90', 100', 11 O', 120'

    Mechanical Information

    AC200-480V models

    Structure Diagram

    Size (in}

    12.6x9.4x6.5

    12.6x9.4x6.5

    OJ Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com

  • The unique light distribution design, light type and angle precision control of the LED light source, to

    avoid light pollution and ineffective utilization of light; soft light, no glare, will not cause eye fatigue of

    workers, improve working efficiency.

    Professional Light Distribution

    Light Distribution Pattern

    Light intensity curve(120W)

    1,81 t.85

    3.82 , ...

    6.24 , ...

    7.65 7.39

    '"

    '·"

    19.47 19.08

    Distance[m] Pyrami1 Diamele (ml

    -CO-Cl80(Halfdlvergenceangle:106.8") -c90-C270(Halfdivergeoc1an,g1&:109.4G)

    041

    E(O") 14'74 E(CiO) 54.7" !SIO E(CO) 53.�0

    E(0°)

    E(C90) 54.7°

    E(CO) 53.4°

    E(0°)

    E(C�O) 5'1.7"

    E(CO} 53A0

    E(O") 1841

    !(C90) 54.7° 151

    E(CO) 53,4° J(,t

    !(0°) 967 E(C90) S�.7° 94

    E(COJ 53.�' 101

    E(O")

    E(C90) 54.7° 31 E(CO) 53.4' 29

    illuminance[bt]

    Plane illuminance curve

    @]

    cd/m2 -g=SS.O--g 6s.o•-y=7S.0°

    Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com

  • Mounting Method

    Explosion proof light can be surface and pendant mounted by bringing down a rigid conduit to the

    light fixture.

    Mounting Option Note:

    Pendant mounting option requires conduit be supplied by the installer.

    Rectangle luminaire mounting

    Ceiling mounting

    Wall mounting

    O 5 Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com

  • Applications

    This luminaire can be used as spot light, down light

    and tunnel light which can provide general illumination

    in hazardous locations, such as:

    • Refinery factory

    • Oil and gasoline loading dock

    • Gas station

    • Painting manufacture workshop

    • Pumping station

    • Metal Smelting Plant

    • Mining

    • Ocean platform

    • Aerospace

    • Chemical plant

    • Vessel

    • Military

    • Flourmill

    • Distillerie

    • Power station

    • Other high humility, high temperature, dusty location ...

    Features

    • High efficacy: up to 140Im/W

    • CRl>70

    • Surface mounting and pendant installation

    • Wide and narrow optics for uniform illumination

    • Copper free aluminum

    • High vibration resistance

    Ratings and Certifications

    • NEMA 4X, IP66

    • UL 1598/U L 1598A/U L844

    • CSA C22.2 No.137/No.250.0

    Class I, Division 2, Groups A,B,C,D

    Class II, Division 1, Groups E,F,G

    Class II, Division 2, Groups E,F,G

    Class Ill

    • Marine and Wet Locations

    • IECEX

    • ATEX

    • 5 years or other warranty period specified in agreement

    • L70 rating for more than 150000 hours

    .... 1.

    lighting

    f!�!!" FC RoHS

    Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com

  • Typical Model Specification

    Product Number -- 20 4000K-5700K

    30 4000K-5700K

    40 4000K-5700K

    50 4000K-5700K

    60 4000K-5700K

    70 4000K-5700K

    PT-20W BYZDA

    PT-30W BYZDA

    PT-40W BYZDA

    PT-SOW BYZDA

    PT-60W BYZDA

    PT-70W BYZDA

    PT-BOW BYZDA 80 4000K-5700K

    Voltage Lumens

    AC 100-277V or AC200-480V 2800

    AC 100-277V or AC200-480V 4200

    AC 100-277V or AC200-480V 5600

    AC 100-277V or AC200-480V 7000

    AC 100-277V or AC200-480V 8400

    AC100-277V 9800

    AC100-277V 11200

    Working Hours

    5 years

    5 years

    5 years

    5 years

    5 years

    5 years

    5 years

    - 70

    70

    70

    70

    70

    70

    70

    "B"=Product series "Y"=D or N:Dimmable or non-dimmable "Z"= CCT, from 4000-5700K "D"=Beam angle:40 ° ,60 ° ,90 ° , 100 ° , 110 ° , 120 °

    Mechanical Information

    AC200-480V models

    Structure Diagram

    Size (in)

    ¢ 10.6x6.5

    ¢ 10.6x6.5

    O 7 Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com

  • The unique light distribution design, light type and angle precision control of the LED light source, to

    avoid light pollution and ineffective utilization of light; soft light, no glare, will not cause eye fatigue of

    workers, improve working efficiency.

    Professional Light Distribution

    Light Distribution Pattern

    Light intensity curve(SOW)

    1.0 1.87

    Distance[m] PyramisDiamete [ml

    -CO-CIS0(Halfdivergenceangla:111.4•)

    osl

    !(0•)

    E(CO)

    E(0°)

    E(CO)

    E(0°)

    E(CO)

    E(O"l

    E(CO)

    E(O"]

    E(CO)

    m

    "

    E(O") �112

    E(CO) �5

    illuminancellxl

    Plane illuminance curve

    cd/m 2

    -g-ss.o•-g-6s.o•-g-1s.o•

    Ph: (866) 258 .0592 , (312) 470 .8058 I con tac t@alg -USA.com I www.pa t r io t led .com

  • Family Tree of Installation

    25 ° Pole Stanchion Pole Stanchion � �9 Wall Arm �r-:;: + �E���a�I�

    I I

    Guard

    Dome Reflector

    Adaptor Conduit

    25 ° Pole Stanchion 3/4" or 1"

    Pole Stanchion 3/4" or 1"

    Wall Arm 3/4" or 1"

    Ex-Box

    +

    Pendant Pole

    Cemog Bcacket

    r � Peodaot Pole LS � �

    I I

    Luminiare Body

    Angle Reflector

    Catalog No.

    25 DPS

    PS

    WA

    Ceiling Bracket Expand Screw CB

    Pendant Pole Use Ex-Box pp

    12° Pendant Pole 3/4" or 1" 12 DPP

    Ex-Box 3/4" EB

    0