Hazardous Areas
-
8/12/2019 Hazardous Area Classification[1][1].Pps
2/15
HAZARDIOUS AREA
Hazardous Areais considered to be an area where a potential for explosionand/or fire exists due to flammable gases / vapors .
The normal processing of certain volatile chemicals.
Accidental failure of storage systems.
-
8/12/2019 Hazardous Area Classification[1][1].Pps
3/15
Area Classification Or Zones
For Safe working Practice, Areas are divided into zone or class.
-
8/12/2019 Hazardous Area Classification[1][1].Pps
4/15
ZONE 0
Zone 0is where Flammable Atmospheres are continuously present, orpresent for long periods, ie. Greater than 1000 hours per year. Permitted form
of protection: Ex'ia'.
LPG Tanks
-
8/12/2019 Hazardous Area Classification[1][1].Pps
5/15
Zone 1
Zone 1is where Flammable Atmospheres are likely to occur during normaloperation. i.e. 10-1000 hours per year. Permitted forms of protection: Any
type of protection suitable for Zone 0 and Ex'd', Ex'ib', Ex'p', Ex'e', Ex's',
Ex'm'.
Oil Storage Area
-
8/12/2019 Hazardous Area Classification[1][1].Pps
6/15
ZONE 2
Zone 2is where Flammable Atmospheres are not likely to occur during normaloperation and if they occur will only exist for a short time. Often referred to as the
'Remotely Hazardous Area'. i.e Less than 10 hours per year. Permitted forms of
protection: Any type of protection suitable for Zone 0 and 1 and Ex'N' or Ex'n', Ex'o',
Ex'q'.
ManufacturingIndustry
-
8/12/2019 Hazardous Area Classification[1][1].Pps
7/15
-
8/12/2019 Hazardous Area Classification[1][1].Pps
8/15
-
8/12/2019 Hazardous Area Classification[1][1].Pps
9/15
-
8/12/2019 Hazardous Area Classification[1][1].Pps
10/15
-
8/12/2019 Hazardous Area Classification[1][1].Pps
11/15
-
8/12/2019 Hazardous Area Classification[1][1].Pps
12/15
-
8/12/2019 Hazardous Area Classification[1][1].Pps
13/15
-
8/12/2019 Hazardous Area Classification[1][1].Pps
14/15
Can you decode EEx d IIA T6 IP 54 now?
EEx d IIA T6 IP 54
EEx Certified equipment for hazardous areas according toEuropean Standards
d Explosion Proof
IIA Propane gas group
T6 Maximum surface temperature as high as 450 deg C
IP 54 Dust protected and Protected against splashed water from
all sides
-