Expert Assessment We utilise specialist power quality meters to diagnose harmonic problems affecting the performance of your electrical distribution system. We provide independent expert advice on the optimum mitigation and correction
techniques.
Solution Design and SupplyPremium Power design passive, active and hybrid filter solutions to optimise the operation and efficiency of your electrical system. Premium Power will work closely with you to supply a solution that meets the technical and economic constraints of
your business.
Installation & CommissioningWe manage the entire installation process. We will commission your solution to guarantee it operates effectively and ensure a full documentation and maintenance planning package is supplied
in line with your technical needs.
Case Study: Abbvie Pharmaceutical
2A Fingal Bay Business Park, Balbriggan, Co Dublin, Ireland+353 1 810 [email protected]
Harmonics Mitigation Solution Providers
CASE STUDY: Pharmaceutical Industry
In 2013, Premium Power carried out an extensive power quality study at a large multi-national pharmaceutical manufacturer in Co. Sligo. This facility had recently introduced a new production process which required a reliable, mission critical electrical supply. A full evaluation was required to ensure that the facility’s electrical distribution network was functioning as required and could support the new pharmaceutical production equipment. The Client also needed assurances that the electrical supply would not cause equipment malfunctions leading to production outages or downtime.
AssessmentPremium Power conducted an extensive power quality metering assessment with advanced portable devices to identify vulnerable points on the network. The assessment highlighted significant breaches of the voltage harmonic limits for controlled and sensitive equipment as stipulated by the IEC61000-2-4 standard.
OutcomePremium Power modelled the facility’s electrical distribution network in a specialist software analysis program. The software model was used to size a filtering solution that would mitigate the harmonic issues. Premium Power supplied and commissioned multiple Active Harmonic Filters at the Client’s facility. This resulted in significant reduction of harmonic currents (ITHD reduced from 55% to 16%), consequently lowering the level of voltage harmonic distortion, maintaining it within the IEC61000-2-4 limits and preventing future failures of critical devices, such as PLCs and controls.