HARMON ENGINEERING & CONTRACTING CO., INC. NOTE

1
880 860 880 840 OAK RIDGE HWY GRASS CHANNEL 36" VALLEY DRAIN 1 2 3 4 5 2% MAX. SLOPE KNOX LOCK BOX GATE WITH POSTS LOCATED WITHIN EASEMENT O A K R I D G E H I G H W A Y J I M J O N E S L A N E EXISTING GRAVEL ROAD CURRENT DRIVEWAY EASEMENT 50' SETBACK FIRE HYDRANT BACKFLOW PREVENTER 1" METER BY WKUD 1-1/2" WATER LINE OUTLET CONTROL STRUCTURE INVERT ELEVATION 828.0 OUTLET DEWATERING DEVICE FAIRCLOTH SKIMMER OR EQUAL SEE DETAIL SHEET C5.O ENERGY DISSIPATOR INVERT ELEVATION 826.0 SEE DETAIL SHEET C5.1 PATIO MODULAR OFFICE (24' X 50') FFE 846.5 PROPERTY LINE 6" GATE VALVE PROPERTY LINE AREA OF DISTURBANCE 50' SETBACK PROPERTY LINE EXISTING LANDSCAPE SCREEN DO NOT DISTURB FUTURE LANDSCAPE BUFFER FUTURE LANDSCAPE BUFFER EXISTING LANDSCAPE SCREEN DO NOT DISTURB EXISTING LANDSCAPE SCREEN DO NOT DISTURB EXISTING LANDSCAPE SCREEN DO NOT DISTURB FUTURE DRIVEWAY AND PARKING FUTURE BUILDINGS FUTURE BUILDINGS PHASE 2 FUTURE DRIVEWAY AND PARKING PHASE 2 AREA OF DISTURBANCE AREA OF DISTURBANCE AREA OF DISTURBANCE EXISTING LANDSCAPE SCREEN DO NOT DISTURB 50' SETBACK 50' SETBACK 50' SETBACK 45° BEND LOG PILE BRUSH PILE MULCH PILE GRAVEL HANDICAP PARKING SIGN GATE VALVE AND BOX DRIVEWAY 6" FIRE LINE STREAM CENTERLINE CONCRETE WASH OUT AREA ASPHALT ASPHALT SWPPP MAILBOX LOCATION POST CONSTRUCTION DETENTION POND SEE SHEETS 5.0- 5.2 FOR DETAILS OPAQUE ORNAMENTAL SCREEN EMERGENCY SPILLWAY EXISTING 48" CULVERT 24" RCP ECB MATTING OPAQUE ORNAMENTAL SCREEN GATE POST CONSTRUCTION PERMANENT ROCK CHECK DAMN SEE DETAIL SHEET C5.2 SHEET REVISION 0 15' 30' 60' SCALE = 1" = 30' NORTH DATE: SCALE: JOB #: DRAWN BY: CHECKED BY: 1" = 30' RG RG 7013.00 11/04/2018 C3.1 LANDSCAPE/ FINAL STABILIZATION PLAN EAST TN TREE SERVICE CONSTRUCTION PLANS PREPARED FOR: 5000 JIM JONES LANE KNOXVILLE, TENNESSEE S LIFE, LLC. NOTE: THREE BUSINESS DAYS PRIOR TO ANY EXCAVATION, CONTRACTOR IS TO CALL THE TENNESSEE CALL-BEFORE-YOU-DIG CENTER 800-351-1111 KEY: SOD SEED MULCH BLUFFTON SOUTH CAROLINA 843.422.0850 (334) 864-9135 / FAX (334) 864-8046 HARMON ENGINEERING & CONTRACTING CO., INC. 13376 C.L. Torbert, Jr. Parkway / LaFayette, Alabama 36862 NOTE: ALL SLOPES THAT EXCEED 3:1 WILL BE STABILIZED WITH APPROVED MATTING.

Transcript of HARMON ENGINEERING & CONTRACTING CO., INC. NOTE

9

2

0

8

8

0

8

6

0

8

8

0

840

OAK RIDGE HWY

GRASS CHANNEL

36" VALLEY DRAIN

1

2

3

4

5

2

%

M

A

X

.

S

L

O

P

E

KNOX LOCK BOX

GATE WITH POSTS LOCATED

WITHIN EASEMENT

O A K R I D G E H I G H W A Y

J

I

M

J

O

N

E

S

L

A

N

E

EX

IST

ING

GR

AV

EL R

OA

D

CURRENT DRIVEWAY

EASEMENT

50' SETBACK

FIRE HYDRANT

BACKFLOW PREVENTER

1" METER BY WKUD

1-1/2" WATER LINE

OUTLET CONTROL STRUCTURE

INVERT ELEVATION 828.0

OUTLET DEWATERING DEVICE

FAIRCLOTH SKIMMER OR EQUAL

SEE DETAIL SHEET C5.O

ENERGY DISSIPATOR

INVERT ELEVATION 826.0

SEE DETAIL SHEET C5.1

P

A

T

I

O

M

O

D

U

L

A

R

O

F

F

I

C

E

(

2

4

'

X

5

0

'

)

F

F

E

8

4

6

.

5

PROPERTY LINE

6" GATE VALVE

PROPERTY LINE

AREA OF DISTURBANCE

50' SETBACK

PROPERTY LINE

E

X

I

S

T

I

N

G

L

A

N

D

S

C

A

P

E

S

C

R

E

E

N

D

O

N

O

T

D

I

S

T

U

R

B

F

U

T

U

R

E

L

A

N

D

S

C

A

P

E

B

U

F

F

E

R

F

U

T

U

R

E

L

A

N

D

S

C

A

P

E

B

U

F

F

E

R

E

X

I

S

T

I

N

G

L

A

N

D

S

C

A

P

E

S

C

R

E

E

N

D

O

N

O

T

D

I

S

T

U

R

B

E

X

I

S

T

I

N

G

L

A

N

D

S

C

A

P

E

S

C

R

E

E

N

D

O

N

O

T

D

I

S

T

U

R

B

E

X

I

S

T

I

N

G

L

A

N

D

S

C

A

P

E

S

C

R

E

E

N

D

O

N

O

T

D

I

S

T

U

R

B

F

U

T

U

R

E

D

R

I

V

E

W

A

Y

A

N

D

P

A

R

K

I

N

G

F

U

T

U

R

E

B

U

I

L

D

I

N

G

S

F

U

T

U

R

E

B

U

I

L

D

I

N

G

S

P

H

A

S

E

2

F

U

T

U

R

E

D

R

I

V

E

W

A

Y

A

N

D

P

A

R

K

I

N

G

P

H

A

S

E

2

AREA OF DISTURBANCE

AREA OF DISTURBANCE

AREA OF DISTURBANCE

EXISTING LANDSCAPE SCREEN

DO NOT DISTURB

5

0

'

S

E

T

B

A

C

K

5

0

'

S

E

T

B

A

C

K

5

0

'

S

E

T

B

A

C

K

45° BEND

L

O

G

P

I

L

E

B

R

U

S

H

P

I

L

E

M

U

L

C

H

P

I

L

E

G

R

A

V

E

L

HANDICAP PARKING SIGN

GATE VALVE AND BOX

D

R

I

V

E

W

A

Y

6" FIRE LINE

STREAM CENTERLINE

CONCRETE WASH OUT AREA

A

S

P

H

A

L

T

A

S

P

H

A

L

T

SWPPP MAILBOX

LOCATION

POST CONSTRUCTION DETENTION

POND SEE SHEETS 5.0- 5.2 FOR

DETAILS

OPAQUE ORNAMENTAL

SCREEN

EMERGENCY SPILLWAY

EXISTING 48" CULVERT

24" RCP

ECB MATTING

OPAQUE ORNAMENTAL

SCREEN GATE

POST CONSTRUCTION PERMANENT

ROCK CHECK DAMN

SEE DETAIL SHEET C5.2

SHEET

REVISION

0 15' 30' 60'

SCALE = 1" = 30'

NORTH

DATE:

SCALE:

JOB #:

DRAWN BY:

CHECKED BY:

1" = 30'

RG

RG

7013.00

11/04/2018

C3.1

LANDSCAPE/ FINAL

STABILIZATION PLAN

EA

ST

T

N T

RE

E S

ER

VIC

E

CO

NS

TR

UC

TIO

N P

LA

NS

P

RE

PA

RE

D F

OR

:

5000 JIM

JO

NE

S LA

NE

KN

OX

VILLE

, T

EN

NE

SS

EE

S L

IF

E, L

LC

.

NOTE:

THREE BUSINESS DAYS PRIOR TO ANY

EXCAVATION, CONTRACTOR IS TO CALL THE

TENNESSEE CALL-BEFORE-YOU-DIG

CENTER 800-351-1111

KEY:

SOD

SEED

MULCH

BLUFFTON

SOUTH CAROLINA

843.422.0850

(334) 864-9135 / FAX (334) 864-8046

HARMON ENGINEERING & CONTRACTING CO., INC.

13376 C.L. Torbert, Jr. Parkway / LaFayette, Alabama 36862

NOTE:

ALL SLOPES THAT EXCEED 3:1 WILL BE STABILIZED

WITH APPROVED MATTING.

AutoCAD SHX Text
NOT FOR CONSTRUCTION NOT FOR CONSTRUCTION RELEASED FOR CONSTRUCTION RELEASED FOR CONSTRUCTION DATE: 12/19/2018 BY: RG
AutoCAD SHX Text
ENGINEERING CONTRACTING ENVIRONMENTAL MANAGEMENT