Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple...

60
Hardware Installation Guide Digi International SyncPort Adapter 90032600 B

Transcript of Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple...

Page 1: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

HardwareInstallation

Guide

Digi International

SyncPort Adapter

90032600 B

Page 2: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

arks

ent a

im- for in the

re pe- edi-

Digi International is a registered trademark of Digi International Inc. The Digi logo is atrademarks of Digi International Inc. All other brand and product names are the trademof their respective holders.

© Digi International Inc. 1996 All Rights Reserved

Information in this document is subject to change without notice and does not represcommitment on the part of Digi International.

Digi provides this document “as is”, without warranty of any kind, either expressed orplied, including, but not limited to, the implied warranties of fitness or merchantabilitya particular purpose. Digi may make improvements and/or changes in this manual orproduct(s) and/or the program(s) described in this manual at any time.

This product could include technical inaccuracies or typographical errors. Changes ariodically made to the information herein; these changes may be incorporated in newtions of the publication.

Digi International Inc.11001 Bren Road EastMinnetonka, MN 55343

Phone

FAXBBS

(800) 344-4273(612) 912-3444(612) 912-4952(612) 912-4800

Digi International GmbHDomkloster 150667 Köln Germany

PhoneFAXBBS

49 221 920-520049 221 920-521049 221 920-5211

Digi International Asia Pte Ltd13-06 Tower ‘A’391A Orchard RoadNgee Ann CitySingapore 238837

PhoneFAXBBS

65 732-131865 732-131265 735-2460

Page 3: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

. . vii . . vii. . vii . . vii. . vii. .viii. . . ix. . . x. . .xi . . xii

. 1 . . . 1 . . . 1 . . 2 . . . 2

. 5 . . 5 . . 5. . . 6 . . 8 . 11. 12. 12. . 13

15 . 15 . 15 . 16 . 19. . 20. 22

Table of ContentsPreface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Purpose. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Scope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Reference Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electronic Emissions Notices. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Telecom Standards. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Industry Canada Compliance Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Bus Interfaces. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .About Digi Manuals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SyncPort ISA Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Quick Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Before Beginning the Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Set the I/O Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Set the WAN Electrical Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Install the SyncPort ISA Adapter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..Run the Memory Map Utility and User Diagnostics . . . . . . . . . . . . . . . . . . . Memory Map Utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . User Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SyncPort Micro Channel Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Quick Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Before Beginning the Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Set the WAN Electrical Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Install the Micro Channel Adapter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .PS/2 Compatible Configuration Steps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Run the Memory Map Utility and User Diagnostics . . . . . . . . . . . . . . . . . . . .

90032600 B Contents Page iii

Page 4: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

. 22. . 23

25 . 25 . 25. . 26. . 28

. 29. . 29 . 29 . 29. 29 . 30 . 30. 30 . 30. . 31 . 31. 31 . 31

. 33

. 37

. . 37 . 38 . 38. 39. 40 . . 40 . . 41. . 42 . 43

. . 49

Memory Map Utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . User Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SyncPort PCI Adapter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Quick Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Before Beginning the Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Install the PCI Adapter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . User Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ISA Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Environmental Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Mechanical Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Micro Channel Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Environmental . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mechanical. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

PCI Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Environmental . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mechanical. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Cable Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digi Support Services. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . In This Chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Web Server: Access to Digi Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . .Internet FTP Server: Access to Digi Drivers . . . . . . . . . . . . . . . . . . . . . . . . . .Digi BBS: Access to Drivers, Information . . . . . . . . . . . . . . . . . . . . . . . . . . . FaxBack Server: Information by FAX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Customer Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Return Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Information About Your System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page iv Contents 90032600 B

Page 5: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

..... 6..... 7..14...21.27.28...29...30

..... 7

..... 8

...13

...14

List of FiguresFigure 1 SyncPort ISA Adapter....................................................................Figure 2 Switch Address ..............................................................................Figure 3 Jumper Locations for Micro Channel Bus Adapter ........................Figure 4 PCI Adapter....................................................................................Figure 5 V.11 (EIA-422/EIA-485) Modem Cable..........................................Figure 6 V.24 (EIA-232/V.28) Modem Cable ................................................Figure 7 V.35 Modem Cable.........................................................................Figure 8 V.36 Modem Cable.........................................................................

List of TablesTable 1 ISA Adapter Line 1 Jumper Settings ............................................Table 2 ISA Adapter Line 2 Jumper Settings ............................................Table 3 Micro Channel Adapter Line 1 Jumper Settings...........................Table 4 Micro Channel Adapter Line 2 Jumper Settings...........................

90032600 B Contents Page v

Page 6: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

Page vi Contents 90032600 B

Page 7: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

f the

ort

ageDigi

ce iter’s

Preface

PurposeThis guide provides information regarding the components and installation oDigi International SyncPort Adapter.

AudienceThis manual is intended for end users who add components to computers.

ScopeThis guide provides step-by-step instructions for installing the Digi SyncPAdapter.

Reference MaterialReference material may be found in the list of Digi publications shown on pviii. Note that items may be added or deleted from this list at any time as publications change.

You may also need the instruction manual that came with your computer sinis referenced in the Digi installation procedure for removing your computcover.

90032600 B Preface Page vii

Page 8: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

ni-

Technical SupportShould you experience problems with Digi equipment, simply call Digi Techcal Support. See page 37.

Publication Number

Title

92000507 WAN Links for Windows NT X.25 Installation andConfiguration Guide

92000508 WAN Links for Windows NT Frame Relay Installationand Configuration Guide

92000242 WAN Links for MP-RAS Installation and Configura-tion Guide

Page viii Preface 90032600 B

Page 9: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

ari-cardslves

tion.

16-y by

s aPortstem

n a

farwide

Glossary ISA

An abbreviation for Industry Standard Architecture. This design allows vous adapters to be added to the system by means of inserting plug-in into expansion slots. Commonly, ISA refers to the expansion slots themseand can be 8-bit or 16-bit slots.

LANLocal area network. A communications architecture that passes informabetween multiple systems over relatively short distances at high speeds

Micro Channel The design of the bus in IBM PS/2 computers which functions as either abit or a 32-bit bus. The Micro Channel can also be driven independentlmultiple bus master processors.

PCI An abbreviation for Peripheral Component Interconnect. It is defined alocal bus system for a computer built to the PCI specification. The SyncPCI adapter does bus mastering for transfer of data. The PCI local bus syallows up to three PCI-compliant expansion cards to be installed icomputer.

WAN

• Wide area network. A network composed of systems that are relativelyapart. A WAN may also encompass a series of LANs connected over a area.

• A network—public or private—that covers a wide geographical area.

90032600 B Preface Page ix

Page 10: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

ss Bed to

envi-nergy,mayuar-entn bey and

ich

fol-and that

may

Emissions and Immunity Standards

Electronic Emissions Notices

Federal Communications Commission (FCC) Statement

Radio Frequency Interference (RFI) (FCC 15.105)

This equipment has been tested and found to comply with the limits for Cladigital devices pursuant to Part 15 of the FCC Rules. These limits are designprovide reasonable protection against harmful interference in a residential ronment. This equipment generates, uses, and can radiate radio frequency eand if not installed and used in accordance with the instruction manual, cause harmful interference to radio communications. However, there is no gantee that interference will not occur in a particular installation. If this equipmdoes cause harmful interference to radio or television reception, which cadetermined by turning the equipment off and on, the user is encouraged to trcorrect the interference by one or more of the following measures:

• Reorient or relocate the receiving antenna.• Increase the separation between the equipment and the receiver.• Connect the equipment into an outlet on a circuit different from that to wh

the receiver is connected.• Consult the dealer or an experienced radio/TV technician for help.

Labeling Requirements (FCC 15.19)

This device complies with Part 15 of FCC rules. Operation is subject to thelowing two conditions: (1) this device may not cause harmful interference, (2) this device must accept any interference received, including interferencemay cause undesired operation.

Modifications (FCC 15.21)

Changes or modifications to this equipment not expressly approved by Digi void the user’s authority to operate this equipment.

Page x Preface 90032600 B

Page 11: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

ow-

erfer-).

Régle-

ow-

Cables (FCC 15.27)

Shielded cables must be used to remain within the Class B limitations.

The Digi SyncPort ISA, Micro Channel and PCI bus interfaces meet the folling electromagnetic emissions standards:

• FCC Part 15, Subpart J, Class B• ICES 003• EN55022, Class B• EN50082• VCCI Class II

Industry Canada Compliance Statement

This Class B digital apparatus meets the requirements of the Canadian Intence-Causing Equipment Regulation (ICES-003 of Industry Canada, Class B

Cet appareil numérique de la Classe B respecte toutes les exigences du ment sur le matériel brouilleur du Canada.

Safety Standards

The Digi SyncPort ISA, Micro Channel, and PCI bus interfaces meet the folling electromagnetic safety standards:

• UL 1950• CSA C22.2 No. 950• EN60950 Safety (TUV)

90032600 B Preface Page xi

Page 12: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

ing

Telecom Standards

The Digi SyncPort ISA, Micro Channel, and PCI interfaces meet the followtelecommunications standards:

• I-CTR2

0168

Page xii Preface 90032600 B

Page 13: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

esepati-

ter-

ing

ter-

ajor

rted

86, Port

IntroductionThis guide provides installation instructions for Digi SyncPort Adapters. Thadapters are intelligent communication units that can be installed in PC-comble or other computer systems.

FeaturesSyncPort Adapters have the following features:

• Two high-speed synchronous communications ports with selectable infaces capable of hardware speeds up to 2.048 Mbps per port

• Fast on-board RISC processor

• Surge protection

• All major electrical interfaces are available as cable options, includV.11/X.21 (EIA-422/485), V.24 (EIA-232 or V.28), V.35 and V.36

• Communication with Frame Relay or X.25 public data networks using exnal DSU/CSUs

In addition, the SyncPort Adapter has gained homologation acceptance for mEuropean countries.

Bus InterfacesThe Digi SyncPort family of adapters consists of versions which can be inseinto each of the following bus types:

IBM-compatible ISA bus

This is used on IBM AT and compatible computers, as well as most 80280386, 80486 and Pentium based computers. For brevity, the Digi Sync

90032600 B Introduction Page 1

Page 14: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

RS-

ter

e of is al.

rchi-bus

foreviceludedfor-

fol-

cro

Adapter designed for the ISA bus interface is termed the SyncPort ISA Adapter throughout the remainder of this manual.

Micro Channel architecture bus

This is used on most IBM PS/2 and compatible computers as well as on6000 computers. For brevity, the Digi SyncPort Adapter designed for theMicro Channel bus interface is called the SyncPort Micro Channel Adapin the remainder of this manual.

PCI bus

The PCI bus is an industry standard local bus system. Again, for the saksimplicity, the Digi SyncPort Adapter designed for the PCI bus interface called the SyncPort PCI Adapter throughout the remainder of this manu

About Digi ManualsThis manual is divided in different chapters based on Industry Standard Atecture (ISA), Micro Channel, or Peripheral Component Interconnect (PCI) systems.

In addition to installing the hardware, you will also need to install softwareyour operating system so programs can communicate with the hardware. Ddriver installation instructions can be found in separate manuals and are incwith the software diskettes. See “Reference Material” on page vii for more inmation.

ComponentsThe carton in which your SyncPort Adapter was shipped should contain thelowing items:

• The SyncPort Adapter, which consists of one of three types: ISA, MiChannel, or PCI

• Modem cables

Page 2 Introduction 90032600 B

Page 15: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

el

ped

• Hardware Installation Guide (this book)

• Diskette containing Adapter Description Files (ADFs) for Micro Channversions only

• Diagnostic diskette

• Loopback plug

Note: Driver software and the corresponding software manual are shipseparately.

90032600 B Introduction Page 3

Page 16: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

Page 4 Introduction 90032600 B

Page 17: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

ress

itr to

e

mt

theDigit side

SyncPort ISA AdapterThis chapter provides instructions for installing Digi SyncPort ISA Adapters.

Quick OverviewPrepare the SyncPort ISA Adapter for installation by selecting the I/O addand WAN electrical interfaces as follows:

• Set the I/O address. The default I/O address is 328h. Change this only ifconflicts with another adapter installed in your personal computer. Refepage 6 for more information.

• Set the WAN electrical interfaces. The WAN interface connectors may bconfigured for selected electrical interfaces. Refer to page 8.

• Install the adapter in an available slot in your computer. Refer to “Install theSyncPort ISA Adapter” on page 11.

• Optional—Run the Memory Map Utility and the User Diagnostics progra.DIGIMMAP.EXE and UD-RISC.EXE are available on the diskette thacame with your adapter. Refer to page 12.

Before Beginning the InstallationBefore installing your SyncPort ISA Adapter, write down the serial number ofadapter in the space provided below. You will need it if you have to contact International regarding this adapter. The serial number is on the componenof the adapter, near the top of the adapter (see Figure 1 on page 6).

Serial Number: _ _ _ _ _ _ _ _ _ _ _ _ _

90032600 B SyncPort ISA Adapter Page 5

Page 18: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

bankr) in

pterset byvail-ange

r, ifse on

Set the I/O AddressPrior to installing the SyncPort ISA Adapter, set the I/O address using the of four DIP switches identified as Switch 1 (called out as SW1 on the adapteFigure 1. These switches are visible through the mounting bracket. Note that theserial number is on the component side of the board, near the top.

Figure 1 SyncPort ISA AdapterImportant: Do not change the setting of Jumper J3. It is set in the fac-tory and must not be changed.

Figure 2 on page 7 illustrates the DIP switch settings. The SyncPort ISA Adauses four contiguous bytes of I/O address space, starting with the address the SW1 DIP switches. To ensure flexibility, seven I/O address ranges are aable: 108h, 118h, 128h, 208h, 228h, 308h and 328h. The default is 328h; chit only if it conflicts with another adapter installed on your computer. Howeveit needs to be changed, you may choose any I/O Address not already in uyour computer.

Page 6 SyncPort ISA Adapter 90032600 B

Page 19: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

r

own in

Step 1. Write the address in the space provided below. You will need it latewhen configuring the software.

I/O address: _ _ _ _ _ _ _ _ _ _ _ _ _

Note: The fourth switch should always be in the down position.

Step 2. Choose one of the starting addresses and set the switches as shFigure 2.

108h 118h 128h

208h 228h 308h

328h (default)

Figure 2 Switch Address

1 2 3 4

OFF

1 2 3 4

OFF

1 2 3 4

OFF

1 2 3 4

OFF

1 2 3 4

OFF

1 2 3 4

OFF

1 2 3 4

OFF

90032600 B SyncPort ISA Adapter Page 7

Page 20: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

nt to

a-

user the

and and

2.

Set the WAN Electrical InterfaceThe WAN interface connectors must be configured to match the equipmewhich the SyncPort ISA Adapter will be connected. The WAN connectors (line 1or line 2) can be individually set for any of these electrical interfaces:

• V.11 (EIA-422/485)

• V.24 (EIA-232/V.28)

• V.35

• V.36

Note that V.11 is equivalent to V.11/X.21 or EIA-422 and X.21; V.24 is equivlent to EIA-232 and V.28.

Jumpers are used to set the electrical interface for each line. This allows theto run one configuration on one line while using a different configuration onother line.

Important: Jumper J3 on the SyncPort ISA Adapter is set in the factory, must not be changed. The correct setting is pins 1 and 2 (the leftmiddle pins) jumpered together.

Tables 1 and 2 provide information regarding jumper settings for Lines 1 and

Page 8 SyncPort ISA Adapter 90032600 B

Page 21: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

Table 1 ISA Adapter Line 1 Jumper Settings

Jumper V.11 pins V.24 pins V.35 pins V.36 pins

J4 1-2 2-3 2-3 1-2

J5 1-2 2-3 1-2 1-2

J7 1-2 2-3 2-3 1-2

J9 1-2 2-3 1-2 1-2

J11 1-2 2-3 2-3 1-2

J13 1-2 2-3 2-3 1-2

J14 1-2 2-3 1-2 1-2

J16 1-2 2-3 1-2 1-2

J19 1-2 2-3 2-3 1-2

90032600 B SyncPort ISA Adapter Page 9

Page 22: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

Table 2 ISA Adapter Line 2 Jumper Settings

Jumper V.11 pins V.24 pins V.35 pins V.36 pins

J1 1-2 2-3 1-2 1-2

J2 1-2 2-3 2-3 1-2

J6 1-2 2-3 2-3 1-2

J8 1-2 2-3 1-2 1-2

J10 1-2 2-3 2-3 1-2

J12 1-2 2-3 2-3 1-2

J15 1-2 2-3 1-2 1-2

J17 1-2 2-3 1-2 1-2

J18 1-2 2-3 2-3 1-2

Page 10 SyncPort ISA Adapter 90032600 B

Page 23: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

r’s

red

plate

ruc-

Install the SyncPort ISA Adapter

To install your SyncPort Adapter, you will need to remove your computecover. If necessary, refer to your computer’s installation manual for help.

Step 1. Turn off your computer’s power.

Step 2. Remove the computer cover.

Step 3. Locate an available 16-bit ISA slot in your computer. It may be coveby a slot plate; if so, remove the slot plate.

Step 4. Insert the SyncPort ISA Adapter into the ISA slot and screw the endto the computer chassis.

Step 5. Replace your computer’s cover.

Step 6. Turn on your computer’s power.

The hardware installation of your SyncPort ISA Adapter is now complete.

Step 7. Refer to the applicable software manual for driver installation insttions. See “Reference Material” on page vii.

90032600 B SyncPort ISA Adapter Page 11

Page 24: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

er the

stem

, ifan-

toere

ette

pearvicesrea

.Run the Memory Map Utility and User Diagnostics

Memory Map Utility

The memory map utility, DIGIMMAP.EXE, is an MS-DOS based executablprogram that is designed to detail locations in memory that are available foDigi product.

To run DIGIMMAP.EXE follow this procedure:

1. Boot your system normally. This should cause any adapters in your syto be initialized.

2. Place a bootable DOS formatted diskette in drive A (or your boot drivedifferent from drive A.) This diskette must have no TSRs or memory mgers present, or DIGIMMAP may give erroneous results.

3. Perform a soft reboot by pressing the <Ctrl> , <Alt> , and <Del> keyssimultaneously.

Note: Do not press the reset button or power cycle your machinereboot; resetting the machine may turn off any adapters that wactivated in Step 1.

4. Now place the diskette containing the diagnostic software in the diskdrive and type the following:

A:\RISC\DIGIMMAP (assuming that you put the diskette in drive A)

5. Read the first screen and then press the <E> key to execute the utility.

6. The center column will contain a list of 32K starting addresses which apto be available. Write down several of these addresses to use—some decan fool the memory mapper by turning their memory off making the aappear to be available. Try addresses in this order:

Addresses beginning with “D” (D0000h and D8000h)Addresses beginning with “C” (C0000h and C8000h)Addresses beginning with “E” (E0000h and E8000h)

Page 12 SyncPort ISA Adapter 90032600 B

Page 25: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

and

le.

o the

op-

m

ics

the

ly.

stallbase you

ent Reset new

helpic.

User Diagnostics

If you wish to verify its operation, you can run the User Diagnostics from the dis-kette that came with your adapter. Use the diagnostics in two ways

• Run basic tests to verify the integrity of the he internal components signals on the adapter

• Use with a loopback plug to test the signals out to the end of the cab

The diagnostic is a DOS-based program. To run the diagnostics program, dfollowing:

1. Attach the loopback plug to the end of the cable if you wish to run the loback test.

2. Go to the \RISC subdirectory of the diskette drive in which the progradiskette is loaded. Example A:\RISC

3. Type UD-RISC on the command line. The main menu of the diagnostwill display. You will need to enter two parameters:

• The board I/O address • The base address

Also, if you wish to use the loopback test capability, you must changeLoopback: option from No to Yes .

4. Press the <E> key to start the tests. The tests will be run consecutivePass/fail status is indicated on the right hand of the screen.

5. If all tests pass, the board is functioning correctly and you are ready to inthe device driver software. Make a note of the I/O address and the address before exiting the program (you will need to specify these wheninstall the device driver software).

6. If failures occur, the most likely cause is a memory conflict. Try a differbase address and execute the diagnostics again. If you get a HardwareError, try a different I/O address (be sure to set the DIP switches for theaddress).

If you have questions about the operation of the diagnostics, refer to thescreens, or access the readme file located in the same directory as the diagnost

90032600 B SyncPort ISA Adapter Page 13

Page 26: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

Page 14 SyncPort ISA Adapter 90032600 B

Page 27: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

nel

s:

eage

ur

mt

rialave theigure

SyncPort Micro Channel AdapterThis chapter provides instructions for installing Digi SyncPort Micro ChanAdapters.

Quick OverviewPrepare for the installation of the SyncPort Micro Channel Adapter as follow

• Set the WAN electrical interfaces. The WAN interface connectors may bconfigured for selected electrical interfaces. Refer to the instructions on p16.

• Install the SyncPort Micro Channel Adapter in an available slot in yocomputer. Refer to the instructions on page 19.

• If your computer is a PS/2, read “PS/2 Compatible Configuration Steps” onpage 20.

• Optional—Run the Memory Map Utility and the User Diagnostics progra.DIGIMMAP.EXE and UD-RISC.EXE are available on the diskette thacame with your adapter. Refer to page 22.

Before Beginning the InstallationBefore installing your Digi SyncPort Micro Channel Adapter, write the senumber of the adapter in the space provided below. You will need it if you hto contact Digi International regarding the adapter. The serial number is onback side (solder side) of the adapter, near the top of the adapter. Refer to F3 on page 16.

Serial Number: _ _ _ _ _ _ _ _ _ _ _ _ _

90032600 B SyncPort Micro Channel Adapter Page 15

Page 28: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

nt to

ter-

to

user

Figure 3 Jumper Locations for Micro Channel Bus Adapter

Set the WAN Electrical InterfaceThe WAN interface connectors must be configured to match the equipmewhich the SyncPort Micro Channel Adapter will be connected. The WAN con-nectors (line 1 or line 2) can be individually set for any of these electrical infaces:

• V.11/X.21 (EIA-422/485)

• V.24 (EIA-232/V.28)

• V.35

• V.36

Note that V.11 is equivalent to EIA-422/485 and X.21; V.24 is equivalent EIA-232 or V.28.

Jumpers are used to set the electrical interface for each line. This allows the

Page 16 SyncPort Micro Channel Adapter 90032600 B

Page 29: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

the

nged.nd

to run one configuration on one line while using a different configuration onother line.

Important: Jumpers J1 and J2 are set in the factory and must not be chaVerify that the jumpers are set to positions 1-2 for both line 1 aline 2.

Table 3 Micro Channel Adapter Line 1 Jumper Settings

Jumper V.11 Pins V.24 Pins V.35 Pins V.36 Pins

J4 1-2 2-3 1-2 1-2

J6 1-2 2-3 2-3 1-2

J8 1-2 2-3 2-3 1-2

J10 1-2 2-3 2-3 1-2

J12 1-2 2-3 1-2 1-2

J14 1-2 2-3 1-2 1-2

J16 1-2 2-3 1-2 1-2

J18 1-2 2-3 2-3 1-2

J20 1-2 2-3 2-3 1-2

90032600 B SyncPort Micro Channel Adapter Page 17

Page 30: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

Table 4 Micro Channel Adapter Line 2 Jumper Settings

Jumper V.11 Pins V.24 Pins V.35 Pins V.36 Pins

J3 1-2 2-3 1-2 1-2

J5 1-2 2-3 2-3 1-2

J7 1-2 2-3 2-3 1-2

J9 1-2 2-3 2-3 1-2

J11 1-2 2-3 1-2 1-2

J13 1-2 2-3 1-2 1-2

J15 1-2 2-3 1-2 1-2

J17 1-2 2-3 2-3 1-2

J19 1-2 2-3 2-3 1-2

Page 18 SyncPort Micro Channel Adapter 90032600 B

Page 31: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

r’s

n the.

theb-

16hatany

Install the Micro Channel AdapterTo install your Micro Channel Adapter, you will need to remove your computecover. If necessary, refer to your computer’s installation manual for help.

Step 1. Turn off your computer’s power.

Step 2. Remove your computer’s cover.

Step 3. Locate an available Micro Channel slot in your computer and loosethumbscrew that holds the slot plate in place. Remove the slot plate

Step 4. Insert the Micro Channel Adapter into the slot, making sure that“fork” is in position under the endplate thumbscrew. Tighten the thumscrew.

Note: The SyncPort Micro Channel Adapter can be installed in either aor 32-bit slot. If you plug the adapter into a 16-bit slot, be sure tthe exposed 32-bit extension does not come into contact with components on the motherboard.

Step 5. Replace the cover on your computer.

Step 6. Turn on your computer’s power.

Your SyncPort Micro Channel Adapter is now installed.

90032600 B SyncPort Micro Channel Adapter Page 19

Page 32: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

han- pro-

ef-t an at

les

to set

) 16

PS/2 Compatible Configuration StepsThis procedure is necessary for PS/2 compatible machines using the Micro Cnel bus only. If you are installing the adapter in an RS-6000 system, skip thiscedure.

Step 1. Insert your working copy (do not use the original copy) of the IBM Rerence Diskette into your boot drive and turn on the computer. Expecerror message—the adapter will not be found in the configuration filethis point.

Step 2. Select Copy an Option Diskette from the main menu. Followthe instructions given on your computer screen for copying ADF fionto your reference diskette.

Step 3. Select Set Configuration from the main menu. Then select RunAutomatic Configuration. Auto-Config will find non-conflict-ing address and interrupt parameters for the adapter. If you choose the parameters manually, you will be given the following choices:

Memory Start Address

Below 1 megabyte:

0D8000h, 0D0000h, 0C8000h, 0C0000h

Sixteenth megabyte:

FC0000h, FA0000h, F80000h

Fourth gigabyte (32-bit slot only):

F0000000h, F2000000h, F4000000h, F6000000h, F8000000h and FA000000h

The memory start addresses F000000h-FA000000h (fourth gigabyteare available only if the adapter is in a 32 bit slot. If the adapter is in abit slot, only addresses 0C0000h-FC0000h are available.

I/O address

108h, 118h, 128h, 208h, 228h, 308h or 328h.

Page 20 SyncPort Micro Channel Adapter 90032600 B

Page 33: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

ruc-

Interrupt Select

IRQ 3, 5, 7, 10, 11, 12, 15 or None (disabled).

Step 4. Refer to the applicable software manual for driver installation insttions. See “Reference Material” on page vii.

90032600 B SyncPort Micro Channel Adapter Page 21

Page 34: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

er the

stem

, ifan-

toere

ette

pearvicesrea

Run the Memory Map Utility and User Diagnostics

Memory Map Utility

The memory map utility, DIGIMMAP.EXE, is an MS-DOS based executablprogram that is designed to detail locations in memory that are available foDigi product.

To run DIGIMMAP.EXE follow this procedure:

1. Boot your system normally. This should cause any adapters in your syto be initialized.

2. Place a bootable DOS formatted diskette in drive A (or your boot drivedifferent from drive A.) This diskette must have no TSRs or memory mgers present, or DIGIMMAP may give erroneous results.

3. Perform a soft reboot by pressing the <Ctrl> , <Alt> , and <Del> keyssimultaneously.

Note: Do not press the reset button or power cycle your machinereboot; resetting the machine may turn off any adapters that wactivated in Step 1.

4. Now place the diskette containing the diagnostic software in the diskdrive and type the following:

A:\RISC\DIGIMMAP (assuming that you put the diskette in drive A)

5. Read the first screen and then press the <E> key to execute the utility.

6. The center column will contain a list of 32K starting addresses which apto be available. Write down several of these addresses to use—some decan fool the memory mapper by turning their memory off making the aappear to be available. Try addresses in this order:

Addresses beginning with “D” (D0000h and D8000h)Addresses beginning with “C” (C0000h and C8000h)Addresses beginning with “E” (E0000h and E8000h)

Page 22 SyncPort Micro Channel Adapter 90032600 B

Page 35: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

and

le.

op-

m

will

the

ly.

stallbase you

ent Reset

helpic.

User Diagnostics

If you wish to verify its operation, you can run the User Diagnostics from the dis-kette that came with your adapter. Use the diagnostics in two ways

• Run basic tests to verify the integrity of the he internal components signals on the adapter

• Use with a loopback plug to test the signals out to the end of the cab

The diagnostic is a DOS-based program.

To run the diagnostics program, do the following:

1. Attach the loopback plug to the end of the cable if you wish to run the loback test.

2. Go to the \RISC subdirectory of the diskette drive in which the progradiskette is loaded. Example A:\RISC

3. Type UD-RISC on the command line. The main menu of the diagnosticsdisplay. You will need to enter two parameters:

• The board I/O address • The base address

Also, if you wish to use the loopback test capability, you must changeLoopback: option from No to Yes .

4. Press the <E> key to start the tests. The tests will be run consecutivePass/fail status is indicated on the right hand of the screen.

5. If all tests pass, the board is functioning correctly and you are ready to inthe device driver software. Make a note of the I/O address and the address before exiting the program (you will need to specify these wheninstall the device driver software).

6. If failures occur, the most likely cause is a memory conflict. Try a differbase address and execute the diagnostics again. If you get a HardwareError, try a different I/O address.

If you have questions about the operation of the diagnostics, refer to thescreens, or access the readme file located in the same directory as the diagnost

90032600 B SyncPort Micro Channel Adapter Page 23

Page 36: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

Page 24 SyncPort Micro Channel Adapter 90032600 B

Page 37: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

s.

er

ter.

beron-

mpo-

SyncPort PCI AdapterThis chapter provides installation instructions for Digi SyncPort PCI Adapter

Quick OverviewPrepare for the installation of the SyncPort PCI Adapter as follows:

• Install the SyncPort PCI Adapter in an available slot in your comput.Refer to the instructions on page 26.

• Optional—Run the User Diagnostics program. UD-PCI.EXE is available on the diskette that came with your adapRefer to page 28.

Before Beginning the InstallationBefore installing your Digi SyncPort PCI Adapter, write down the serial numof the adapter in the space provided below. You will need it if you have to ctact Digi International regarding the adapter. The serial number is on the conent side of the adapter, near the top of the adapter.

Serial Number: _ _ _ _ _ _ _ _ _ _ _ _ _

90032600 B SyncPort PCI Adapter Page 25

Page 38: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

. If

late.

mput-

Figure 4 PCI Adapter

Install the PCI Adapter

To install your PCI Adapter, you will need to remove your computer’s covernecessary, refer to your computer’s installation manual for help.

Step 1. Turn off your computer’s power.

Step 2. Remove your computer’s cover.

Step 3. Locate an available PCI slot in your computer and remove the slot p

Step 4. Insert the adapter into the PCI slot and screw the endplate to the coer chassis.

Serial Number

Line 2

Line 1

Page 26 SyncPort PCI Adapter 90032600 B

Page 39: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

ruc-

Step 5. Replace your computer’s cover.

Step 6. Turn on your computer’s power.

The hardware installation of your SyncPort PCI Adapter is now installed.

Step 7. Refer to the applicable software manual for driver installation insttions. See “Reference Material” on page vii.

90032600 B SyncPort PCI Adapter Page 27

Page 40: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

and

le.

op-

is-

the

ively.

stallbase you

ent Reset

helpic.

User DiagnosticsIf you wish to verify its operation, you can run the User Diagnostics from the dis-kette that came with your adapter. Use the diagnostics in two ways

• Run basic tests to verify the integrity of the he internal components signals on the adapter

• Use with a loopback plug to test the signals out to the end of the cab

The diagnostic is a DOS-based program.

To run the diagnostics program, do the following:

1. Attach the loopback plug to the end of the cable if you wish to run the loback test.

2. Go to the \PCI subdirectory of the diskette drive in which the program dkette is loaded. Example A:\PCI

3. Type UD-PCI on the command line.

The main menu of the diagnostics will display. The program will display adapter base address that was assigned by the host.

If you wish to use the loopback test capability, you must change the Loop-back: option from No to Yes .

4. Press the <E> key to start the tests. The tests will be run consecutPass/fail status is indicated on the right hand of the screen.

5. If all tests pass, the board is functioning correctly and you are ready to inthe device driver software. Make a note of the I/O address and the address before exiting the program (you will need to specify these wheninstall the device driver software).

6. If failures occur, the most likely cause is a memory conflict. Try a differbase address and execute the diagnostics again. If you get a HardwareError, try a different I/O address.

If you have questions about the operation of the diagnostics, refer to thescreens, or access the readme file located in the same directory as the diagnost

Page 28 SyncPort PCI Adapter 90032600 B

Page 41: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

Specifications

ISA Adapter

Power Requirements

+5 Volts ± 5%, 2.5 amps typical

+12 Volts ± 5%, 100 milliampere typical

-12 Volts ± 5%, 40 milliampere typical

Environmental RequirementsTemperature: 0o C to 55o C (32o F to 131o F)

Relative Humidity: 5% to 95% non-condensing

Air Movement: 30 CFM Forced

Altitude: 0 to 3658 meters (0 to 12,000 feet)

Mechanical Information Length: 332.74 mm (13.1 inches)

Width: 15.24 mm (.6 inches)

Height: 114.3 mm (4.5 inches)

Weight: 340.19 grams (12 ounces)

90032600 B Specifications Page 29

Page 42: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

Micro Channel Adapter

Power Requirements

+5 Volts ± 5%, 1.3 amps typical

+12 Volts ± 5%, 40 milliampere typical

-12 Volts ± 5%, 40 milliampere typical

EnvironmentalTemperature: 0o C to 55o C (32o F to 131o F)

Relative Humidity: 5% to 95% non-condensing

Air Movement: 30 CFM Forced

Altitude: 0 to 3658 meters (0 to 12,000 feet)

MechanicalLength: 292.1 mm (11.5 inches)

Width: 15.24 mm (.6 inches)

Height: 88.26 mm (3.475 inches)

Weight: 231.05 grams (8.15 ounces)

Page 30 Specifications 90032600 B

Page 43: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

PCI Adapter

Power Requirements

+5 Volts ± 5%, 1.5 Amps typical

+12 Volts ± 5%, 40 milliampere typical

-12 Volts ± 5%, 40 milliampere typical

EnvironmentalTemperature: 0o C to 55o C (32o F to 131o F)

Relative Humidity: 5% to 95% non-condensing

Air Movement: 30 CFM Forced

Altitude: 0 to 3658 meters (0 to 12,000 feet)

MechanicalLength: 6.875 inches (1/2 length card)

Width: .55 inches

Height: 4.2 inches

Weight: 12 ounces

90032600 B Specifications Page 31

Page 44: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

Page 32 Specifications 90032600 B

Page 45: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

oop-

Cable DiagramsThis chapter provides illustrations of SyncPort Adapter modem cables and lback plugs.

Figure 5 Pinout for V.11 (EIA-422/EIA-485) Modem Cableand Loopback Plug

90032600 B Cable Diagrams Page 33

Page 46: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

Figure 6 Pinout for V.24 (EIA-232/V.28) Modem Cable and Loopback Plug

Page 34 Cable Diagrams 90032600 B

Page 47: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

Figure 7 Pinout for V.35 Modem Cable and Loopback Plug

90032600 B Cable Diagrams Page 35

Page 48: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

Figure 8 Pinout for V.36 Modem Cable and Loopback Plug

Page 36 Cable Diagrams 90032600 B

Page 49: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

Digi Support Services

In This Chapter

This chapter describes Digi support services. It covers the following topics:

Topic Page

Web Server: Access to Digi Information 38

Internet FTP Server: Access to Digi Drivers 38

Digi BBS: Access to Drivers, Information 39

FaxBack Server: Information by FAX 40

Customer Service 40

Return Procedures 41

Technical Support 42

Information About Your System 43

90032600 B Digi Support Services Page 37

Page 50: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

riv-n in-

s

and

ting

ry

Web Server: Access to Digi InformationPurpose

The Digi Web server provides you with access to product information, ders, manuals, new product announcements, programs, related installatioformation and application stories.

AddressYou can access the Web server at http://www.dgii.com.

Internet FTP Server: Access to Digi DriverPurpose

The Digi anonymous FTP server provides you with access to Digi driversrelated installation information.

AddressYou can access the FTP server at ftp.dgii.com.

Tips on Using the FTP ServerWhen you access the Digi FTP server, do the following:

• Log in as anonymous• Enter your E-mail address when asked for a password.• Locate drivers and related installation tips in the appropriate opera

system/board type directory. • Enter “bin” before downloading any driver files to ensure proper bina

transfer. • Enter “ASCII” before downloading ASCII text files.• See the text file, download.doc for information on uncompressing files

after downloading.

Page 38 Digi Support Services 90032600 B

Page 51: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

Digi

15

ugh

.

Digi BBS: Access to Drivers, InformationPurpose

The Digi electronic bulletin board service (BBS) provides the following:• Access to general and technical information about Digi’s products• Access to the most recent software driver updates and upgrades• An opportunity to leave messages for Technical Support regarding

products.

Modem Support The Digi BBS supports the following:

• Line speeds of 1200, 2400, 9600, 14,400, and 28,800 bps• V.32, HST 14.4, V.42 and V.42bis standards, with full MNP class

error correction and data compression. • Modem settings of eight bits, no parity and one stop bit (8 N 1), tho

other settings may also work.• Zmodem, Xmodem, Ymodem, Kermit and other download protocols

Telephone NumbersHere are the telephone numbers for access to the BBS:

• In North America: (612) 912-4800• In Europe: +49 221 9205211• In Asia: +65 735 2460

90032600 B Digi Support Services Page 39

Page 52: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

n by

s.

ow-

rn

and

FaxBack Server: Information by FAXPurpose

The FaxBack server provides you with manuals and technical informatioFAX.

How to Use the FaxBack ServerCall (612) 912-4990 on a touch-tone telephone and listen for instruction

Customer ServicePurpose

Digi’s staff of customer service representatives can help you with the folling:

• Software and documentation update requests• Returned Merchandise Authorizations (RMAs)—if you need to retu

your Digi product for repair.

How to Reach Customer ServiceTo reach Customer Service, do any of the following:

• Telephone (612) 912-3456 • Fax (612) 912-4959 • Send E-mail to [email protected] (Please include your telephone

FAX numbers.)

Page 40 Digi Support Services 90032600 B

Page 53: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

s re-thet de-firstives

a

ress

eet,

Return ProceduresWarranty Information

Digi products have a five-year parts and labor warranty, and Digi assumesponsibility for any defective parts, according to the limits specified in warranty. However, many problems are due to factors other than producfects. To save you time and possibly additional cost, Digi asks that you try to resolve difficulties by contacting our technical support representatat (612) 912-3456.

Return ProcedureTo return your Digi product for repair do the following:

• Obtain an RMA (Returned Merchandise Authorization) number fromDigi customer service representative.

• Place the RMA number on the shipping carton, on or near the addlabel.

• Ship authorized returns to Digi International, 10000 West 76th StrEden Prairie, MN 55344.

90032600 B Digi Support Services Page 41

Page 54: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

p-

eltion

t),

tive:-h-

any

p-

ail

Technical SupportIntroduction

If you experience difficulty with a product, Digi has a staff of technical suport specialists to assist you.

Support Process Follow this process to resolve the problem with Digi products:

• First, contact your Digi dealer or distributor. They provide first-levtechnical support and have the training to help you with any installaquestions or difficulties you may have.

• If you still experience difficulties (after contacting first-level supporcontact Digi Support Services.

Tips for When You Call Technical SupportHere are some tips to ensure that your call to Technical Support is produc

• Prior to calling, please fill out the form “Information About Your System” that follows. The information you supply here provides your tecnical support representative with a clear picture of your system andpotential conflicts between devices.

• Please call from a position where you can operate your system.

How to Contact Digi Technical SupportTo reach Digi Technical Support:

• In USA: Telephone (612) 912-3456; FAX (615) 834-5399; E-mail [email protected]

• In Europe: Telephone +49 221 920520; FAX +49 221 9205210; [email protected]

• In Asia: Telephone +65 732 1318; FAX +65 732 1312; E-mail [email protected]

Page 42 Digi Support Services 90032600 B

Page 55: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

Information About Your SystemSerial number of your Digi product:________________________

Computer make:_______________________________________

Computer model:_______________________________________

Computer clock speed:___________________________________

Hard disk controller:

Type:______________________________________________

Memory addressed at:_________________________________

I/O port used:________________________________________

IRQ:_______________________________________________

LAN card:

Type:______________________________________________

Memory addressed at:_________________________________

I/O port used:________________________________________

IRQ:_______________________________________________

Other

Type:______________________________________________

Memory addressed at:_________________________________

I/O port used:________________________________________

IRQ:_______________________________________________

90032600 B Digi Support Services Page 43

Page 56: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

Page 44 Digi Support Services 90032600 B

Page 57: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

Index

16-bit slotISA 11

32-bit extension19

AADF files 20audiencevii

Ccables33Canada, industry compliancexiicomponents2customer service40

DDIGIMMAP.EXE 12, 22DIP switch 6

EEIA-232 8, 16EIA-422/48 8, 16electrical interfaces1electronic emissions noticesxemissions standardsxienvironmental30, 31environmental requirements29

FFaxBack server40FCC xfeatures1FTP server38

Gglossaryix

Hhomologation1

II/O address6

ISA adapter6I/O address ranges6IBM Reference Diskette20immunity standardsxiinstallation

SyncPort ISA adapter8SyncPort Micro Channel19SyncPort PCI adapter26

ISA ix, 2ISA adapter

default 6DIP switch 6jumper J38power requirements29V.11 8V.24 8V.35 8V.36 8

ISA bus 1

JJ3, jumper6

90032600 B Index 45

Page 58: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

LLAN ixLine 1 8

Mmechanical information29memory map utility

ISA 12Micro Channel22

memory start address20Micro Channel

mechanical30Micro Channel adapter15

environment30installation 19overview 15power 30serial number15V.11 16V.24 16V.35 16V.36 16

Micro Channel architectureix, 2modem cables33

Ooverview

ISA 5Micro Channel15PCI 25

PPCI ix, 2PCI adapter31

environmental31installation 26mechanical31

overview 25power 31

PCI bus2Peripheral Component Interconnect2power requirements29, 30PS/2 compatible machines20Publicationviiipurposevii

Rreference materialviireturn procedures41RISC processor1RS-6000 system20

SSafety xisafety standardsxiscopeviiserial number5, 15support services37–41surge protection1switch address7SyncPort adapter1SyncPort modem cables33

Ttechnical supportviii , 42

UUD-PCI.EXE 28UD-RISC.EXE 13, 23user diagnostics

ISA 13Micro Channel23PCI 28

VV.11 8, 16

46 Index 90032600 A

Page 59: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

V.11 modem cable33V.24 8, 16V.24 modem cable34V.28 8, 16V.35 8, 16V.35 modem cable35V.36 8, 16V.36 modem cable36

WWAN ixWAN electrical interface8, 16warranty information41World Wide Web server38

90032600 B Index 47

Page 60: Hardware Installation Guideftp1.digi.com/support/documentation/90032600B.pdf · between multiple systems over relatively short distances at high speeds. Micro Channel The design of

48 Index 90032600 B