Hand Calculation Method for Orifice Design

16
Chevron Corporation B-1 July 1999 Appendix B. Hand Calculation Method for Orifice Design Abstract This appendix explains how to perform the calculations for orifice plate design by hand. For manual look-up of the orifice coefficient, S (given beta) or the diameter ratio, beta (given S), the following eight figures are provided: Orifice calculation sheets have been prepared for guidance through the orifice calcu- lation steps. Calculation sheets filled in with appropriate examples are attached. The four orifice calculation sheets are as follows: LIQUID, square-edge orifice, Form ICM-EF-59B (Figure B-9) LIQUID, quadrant-edge orifice, Form ICM-EF-59C (Figure B-10) GAS, square-edge orifice, Form ICM-EF-59D (Figure B-11) VAPOR/STEAM, square-edge orifice, Form ICM-EF-59E (Figure B-12) Note that in these calculation sheets, the term "sharp edge" is used instead of "square-edge." Results of the hand calculations agree closely with the computer program ORIFICE. The two types of calculations that can be performed are orifice sizing and orifice re- ranging, except for quadrant-edge. Figure B-1 Flange Taps - 6 Inch Pipe Size (6.056 in.); S vs. Beta for Different R D Values (Based on Data from ISO 5167) Figure B-2 Flange Taps; Pipe Size Corrections for S Values (Based on Data from ISO 5167) Figure B-3 Radius Taps; S vs. Beta for Different R D Values (Based on Data from ISO 5167) Figure B-4 Corner Taps; S vs. Beta for Different R D Values (Based on Data from ISO 5167) Figure B-5 Pipe Taps; S vs. Beta for Different R D Values (Based on Data from ISO 5167) Figure B-6 ASME Small Bore with Flange Taps; S vs. Beta for Different R D Values—1 in. to 1-1/2 in. Pipe Size (Based on Data from "Fluid Meters: Their Theory and Applica- tion", 6th ed., 1971. Courtesy of ASME) Figure B-7 ASME Small Bore with Corner Taps (.546 in.); S vs. Beta for Different R D Values—1/2 in. Schedule 80 Pipe Size (Based on Data from "Fluid Meters: Their Theory and Application", 6th ed., 1971. Courtesy of ASME) Figure B-8 Quadrant — Edge Data; S and Thickness Ratio vs. Beta

Transcript of Hand Calculation Method for Orifice Design

Page 1: Hand Calculation Method for Orifice Design

ICE.

e re-

n

Appendix B. Hand Calculation Method for Orifice Design

AbstractThis appendix explains how to perform the calculations for orifice plate design by hand. For manual look-up of the orifice coefficient, S (given beta) or the diameter ratio, beta (given S), the following eight figures are provided:

Orifice calculation sheets have been prepared for guidance through the orifice calcu-lation steps. Calculation sheets filled in with appropriate examples are attached. The four orifice calculation sheets are as follows:

• LIQUID, square-edge orifice, Form ICM-EF-59B (Figure B-9)• LIQUID, quadrant-edge orifice, Form ICM-EF-59C (Figure B-10)• GAS, square-edge orifice, Form ICM-EF-59D (Figure B-11)• VAPOR/STEAM, square-edge orifice, Form ICM-EF-59E (Figure B-12)

Note that in these calculation sheets, the term "sharp edge" is used instead of "square-edge."

Results of the hand calculations agree closely with the computer program ORIF

The two types of calculations that can be performed are orifice sizing and orificranging, except for quadrant-edge.

Figure B-1 Flange Taps - 6 Inch Pipe Size (6.056 in.); S vs. Beta for Different RD Values (Based on Data from ISO 5167)

Figure B-2 Flange Taps; Pipe Size Corrections for S Values (Based oData from ISO 5167)

Figure B-3 Radius Taps; S vs. Beta for Different RD Values (Based on Data from ISO 5167)

Figure B-4 Corner Taps; S vs. Beta for Different RD Values (Based on Data from ISO 5167)

Figure B-5 Pipe Taps; S vs. Beta for Different RD Values (Based on Data from ISO 5167)

Figure B-6 ASME Small Bore with Flange Taps; S vs. Beta for Different RD Values—1 in. to 1-1/2 in. Pipe Size (Based on Data from "Fluid Meters: Their Theory and Applica-tion", 6th ed., 1971. Courtesy of ASME)

Figure B-7 ASME Small Bore with Corner Taps (.546 in.); S vs. Betafor Different RD Values—1/2 in. Schedule 80 Pipe Size (Based on Data from "Fluid Meters: Their Theory and Application", 6th ed., 1971. Courtesy of ASME)

Figure B-8 Quadrant — Edge Data; S and Thickness Ratio vs. Beta

Chevron Corporation B-1 July 1999

Page 2: Hand Calculation Method for Orifice Design

Appendix B Instrumentation and Control Manual

B1.0 Calculation Procedure1. Fill in the STREAM PROPERTY input blocks.

2. Fill in the FLOW RATE input blocks.

3. Fill in the ORIFICE DATA input blocks.

TEMPERAURE -- degrees Fahrenheit for liquid and vapor/steam

-- degrees Rankine = °F + 460 for gas

PRESSURE -- PSIA for gas and vapor

LIQUID SPECIFIC GRAVITY -- Gb at 60 F (Gb for water = 1.00)

VAPOR/STEAM SPECIFIC GRAVITY -- cu.ft./lb.

-- for steam, use steam tables

GAS SPECIFIC GRAVITY -- Ideal sp. gr. is used

= M.W. gas/M.W. dry air

= Zb × Real sp. gr.

LIQUID KINEMATIC VISCOSITY -- use centistokes

GAS AND VAPOR ABSOLUTE VISCOSITY

-- use centipoise

UNITS: For liquid use BPD, BPH, GPM, or GPH. For vapor use lbs/hour; for gas use SCFH.

FULL SCALE: Flow that creates a dp across the orifice taps equal to the maximum value of the dp transmitter range.

NORMAL: For square-edge and ASME small-bore this should be the mid-range dp value, which equals .707 × (full-scale flow rate)

1/3 FS: For quadrant-edge, equal to .333 × (full-scale flow rate)

TYPE OF ORIFICE PLATE -- Square-edge

-- ASME small-bore

-- Quadrant-edge

TYPE OF TAPS -- Flange, radius, corner or pipe for

square-edge

-- Flange or corner only for ASME

small-bore

-- Flange for quadrant-edge

PIPE INSIDE DIAMETER -- Use 3 decimal places

ORIFICE DIAMETER -- Entered for orifice re-ranging

calculation

July 1999 B-2 Chevron Corporation

Page 3: Hand Calculation Method for Orifice Design

Instrumentation and Control Manual Appendix B

ice.

4. Fill in the CORRECTIONS FACTORS.

5. Calculate Pipe Reynold’s Number.

Space is provided for values in equations.

See examples on sheets provided.

6. Calculate orifice size or dp range for square-edge or ASME small-bore orif

Given h, Find dFill in equations and solve for S.Look up beta ratio in table.Interpolation is necessary.Use Table in Figure B-2 to correct for pipe size other than 6-inches (2-12 inches).Use Reynold’s number column that is closest to value calculated in step 5.

Given d, Find hCalculate beta ratio.Look up S in table.Interpolation is necessary.

Use Reynold’s number that is closest to value calculated in Step 5.

See examples on sheets provided.

7. Calculation for quadrant-edge orifice size.

-- Use 3 decimal places

FULL SCALE DP -- Entered for orifice sizing calcula-tion

-- Standard value = 100 inches of water

Fa -- Correction for thermal expansion of orifice meter at flowing temperature found in ASME MFC-3M Tables or API MPMS. Chapter 14.3/AGA-3.

Y -- Gas expansion factor for mid-scale flow Y1 = correction based on upstream pressure Y2 = correction based on downstream pressure Look up in table or chart - use mid-range differential pressure (dp)

Fpv -- Supercompressibility correction factor Rarely used in refinery calculations (usually set = 1.0)Look up in table or chart when used.

Zb -- Compressibility factor at 60°F, 1 Atm Rarely used in refinery calculations (usually set = 1.0) Look up in table or chart when used.

Chevron Corporation B-3 July 1999

Page 4: Hand Calculation Method for Orifice Design

Appendix B Instrumentation and Control Manual

ad-

Select a plate thickness, look up values from Figure B-8, and calculate the differential pressure h.

If h is too large, make plate thicker; if too small, make plate thinner, and repeat calculation. h should equal about 100 inches of water.

The permissible range of Reynold’s numbers (at 1/3 full-scale flow) for a qurant-edge orifice is a function of the beta ratio:

See example on calculation sheet provided.

beta ratio 0.2 0.3 0.4 0.5 0.6

min. RD 670.0 770.0 630.0 450.0 320.0

max. RD 17500.0 28000.0 45000.0 70000.0 85000.0

July 1999 B-4 Chevron Corporation

Page 5: Hand Calculation Method for Orifice Design

Instrumentation and Control Manual Appendix B

Fig. B-1 Flange Taps - 6 Inch Pipe Size (6.056 in.); S vs. Beta for Different RD Values (Based on Data from ISO 5167)

Chevron Corporation B-5 July 1999

Page 6: Hand Calculation Method for Orifice Design

Appendix B Instrumentation and Control Manual

Fig. B-2 Flange Taps; Pipe Size Corrections for S Values (Based on Data from ISO 5167)

July 1999 B-6 Chevron Corporation

Page 7: Hand Calculation Method for Orifice Design

Instrumentation and Control Manual Appendix B

Fig. B-3 Radius Taps; S vs. Beta for Different RD Values (Based on Data from ISO 5167)

Chevron Corporation B-7 July 1999

Page 8: Hand Calculation Method for Orifice Design

Appendix B Instrumentation and Control Manual

Fig. B-4 Corner Taps; S vs. Beta for Different RD Values (Based on Data from ISO 5167)

July 1999 B-8 Chevron Corporation

Page 9: Hand Calculation Method for Orifice Design

Instrumentation and Control Manual Appendix B

Fig. B-5 Pipe Taps; S vs. Beta for Different RD Values (Based on Data from ISO 5167)

Chevron Corporation B-9 July 1999

Page 10: Hand Calculation Method for Orifice Design

Appendix B Instrumentation and Control Manual

Fig. B-6 ASME Small Bore with Flange Taps; S vs. Beta for Different RD Values—1 in. to 1-1/2 in. Pipe Size (Based on Data from "Fluid Meters: Their Theory and Application", 6th ed., 1971. Courtesy of ASME)

July 1999 B-10 Chevron Corporation

Page 11: Hand Calculation Method for Orifice Design

Instrumentation and Control Manual Appendix B

Fig. B-7 ASME Small Bore with Corner Taps (.546 in.); S vs. Beta for Different RD Values—1/2 in. Schedule 80 Pipe Size (Based on Data from "Fluid Meters: Their Theory and Application", 6th ed., 1971. Courtesy of ASME)

Chevron Corporation B-11 July 1999

Page 12: Hand Calculation Method for Orifice Design

Appendix B Instrumentation and Control Manual

Fig. B-8 Quadrant — Edge Data; S and Thickness Ratio vs. Beta

July 1999 B-12 Chevron Corporation

Page 13: Hand Calculation Method for Orifice Design

Instrumentation and Control Manual Appendix B

Fig. B-9 Orifice Calculation Sheet—Liquid, Square-edge Orifice

Chevron Corporation B-13 July 1999

Page 14: Hand Calculation Method for Orifice Design

Appendix B Instrumentation and Control Manual

Fig. B-10 Orifice Calculation Sheet—Liquid, Quadrant-edge Orifice

July 1999 B-14 Chevron Corporation

Page 15: Hand Calculation Method for Orifice Design

Instrumentation and Control Manual Appendix B

Fig. B-11 Orifice Calculation Sheet—Gas, Square-Edge Orifice

Chevron Corporation B-15 July 1999

Page 16: Hand Calculation Method for Orifice Design

Appendix B Instrumentation and Control Manual

Fig. B-12 Orifice Calculation Sheet—Vapor/Steam, Square-Edge Orifice

July 1999 B-16 Chevron Corporation