Halton – Residential Ventilation System€¦ · Halton Central vacuum cleaning general benefits...

20
Enabling Wellbeing Halton – Residential Ventilation System

Transcript of Halton – Residential Ventilation System€¦ · Halton Central vacuum cleaning general benefits...

Page 1: Halton – Residential Ventilation System€¦ · Halton Central vacuum cleaning general benefits • Healthy - removal of hazardous micro dust (the air is filtered, then blown out

Enabling Wellbeing

Halton – Residential Ventilation System

Page 2: Halton – Residential Ventilation System€¦ · Halton Central vacuum cleaning general benefits • Healthy - removal of hazardous micro dust (the air is filtered, then blown out

2

Halton is passionate about indoor environment. We offer

business enhancing solutions for comfortable, energy-

efficient and safe environments, for companies that

value wellbeing and productivity of their customers and

personnel.

Enabling wellbeing

Page 3: Halton – Residential Ventilation System€¦ · Halton Central vacuum cleaning general benefits • Healthy - removal of hazardous micro dust (the air is filtered, then blown out

3

Halton – Indoor climate solutions for residential buildings

Ventilation 4

Central vacuum cleaning 10

Fire safety 14

Air filtering 16

References 18

Page 4: Halton – Residential Ventilation System€¦ · Halton Central vacuum cleaning general benefits • Healthy - removal of hazardous micro dust (the air is filtered, then blown out

4

Page 5: Halton – Residential Ventilation System€¦ · Halton Central vacuum cleaning general benefits • Healthy - removal of hazardous micro dust (the air is filtered, then blown out

5

Central ventilation creates a safe, healthy, and

comfortable indoor environment. In contrast to natural

ventilation a centralised system offers sufficient

supply of clean air at all times, in any situation.

Flat- or space-specified ventilation allows easy and

instantaneous adjustments in line with temporary

changes in the requirements indoors. Correct indoor

humidity conditions and stable indoor temperature

prevent dampness from accumulating in the

structures and create a comfortable indoor climate.

Halton’s demand-based systems, room-specific

adjustments, and carefully designed functionality

result in energy-efficiency.

Halton offers high-quality solutions for ventilation in

residential buildings. The products are quiet, easy to

install and clean, and have a wide operation range.

Central ventilation is also suitable for renovation sites.

Benefits to residents

•Cleanandhealthyindoorair

•Levellingofflargedailyswingsintemperature,

through cooling of the structures at night

• Indoorhumiditythatremainsataconstantlevel

•Ventilationthatisadjustableforindividualflats

•Energy-efficiency,forloweroperationcosts

•Flatsthatstayinthebestpossibleconditionfor

longer, with less need for renovation and an increase

in comfort

•Quietoperation

•Easyandquickcleaning/servicing

•CarefreelivingwithHaltonmaintenanceservices

Benefits to the developer

•Easeofinstallation

•Productsthatareadjustableperflat.

•Awiderangeofoperation

•Morefreedomforthedesign,thankstospace-

saving products

Benefits for investors

•Keepingthepropertyinitsbestconditionlonger,

with less need for renovation and lower costs

•Higherpropertyvalue,withacomfortableliving

environment

Healthy buildings and clean indoor air through central ventilation

Page 6: Halton – Residential Ventilation System€¦ · Halton Central vacuum cleaning general benefits • Healthy - removal of hazardous micro dust (the air is filtered, then blown out

6

Demand based apartment ventilation system

Application description

The demand-based apartment ventilation system

provides the desired ventilation rate in different

operation conditions according to the occupants push

button commands.

The airflow rate can be selected by the occupant

between three different airflow rates. This way the

indoor air quality can be provided energy-efficiently in

changing load conditions. Also possible for continuous

adjustment with automatic room controller.

MIN

Minimumairflowtoensurehygienicconditionswhile

space or apartment is unoccupied.

NORM

Normal airflow to ensure comfort conditions while

space or apartment is occupied and on normal daily

use.

MAX

Boost airflow for temporary use in example for high

occupancy rate or after showering.

The air flow control is independent of the pressure

variationsintheductwork.

The room pressure balance can be maintained at the

desired level – over-pressurized or under- pressurized

Flat-specificmaintenancerequirementsarelow,as

there is no filters and engines.

max

norm

min

l/sm3/h

Airflow rate chart

Page 7: Halton – Residential Ventilation System€¦ · Halton Central vacuum cleaning general benefits • Healthy - removal of hazardous micro dust (the air is filtered, then blown out

7

Halton HHW is integrated supply and exhaust airflow

control unit optimized for modern high-rise residential

buildingconstruction.Inoneframeisalsointegrated

effectiveattenuatorsandreadymadeelectrics.It

guarantees low operating sound level and reliable

operation even with small airflow rates.

HHW saves installation time as all necessary

components are integrated to one frame and no

separate transformer, pipe couplings or inspection

hatches are needed.

HHVsingleisseparatedsupplyorexhaustairflow

control unit, suitable for flats where supply and

exhaust ventilation ducts are not side by side.

Kitchenhoodorbathroomstatuscanbemonitored

and so the pressure and humidity conditions can be

controlled during the use of those.

Commissioningandductcleaningareeasilydone.

Inspectingoradjustingofairflowratescanbedoneby

connecting a hand device to the room controller so

ceilingdoesnotneedtobeopened.Integratedservice

hatch provides excellent access for duct sweeping.

Halton integrated solution

Centralized ventilation with Halton HHW duo unit

Centralized ventilation with Halton HHW connected with kitchen hood duct

Centralized ventilation with Halton HHV single units

Page 8: Halton – Residential Ventilation System€¦ · Halton Central vacuum cleaning general benefits • Healthy - removal of hazardous micro dust (the air is filtered, then blown out

8

Air-flow management

Combined air-flow control unit for supply and exhaust air

Air-flow control unit for either supply or exhaust air

Air-flow control unit Air-flow balancing, adjustment, and measurement unit

HHW HHV HFB PRA

Adjustment method automatic automatic automatic manual

Air-flow measurement built-in measuring built-in measuring built-in measuring built-in flow nozzles for measuring device

Integrated attenuator yes (polyester fibre) yes (polyester fibre) optional -

Pressure-independent operation

yes yes yes no

Connection sizes (Ø mm) 125 125 100, 125, 160, 200, 250, 315, 400, 500

100, 125, 160, 200, 250, 315, 350, 400, 500, 630, 800, 1000

Duct-cleaning access yes yes optional with attenuator optional up to size 630

Duct-cleaning enabled through the unit

no no no yes,up to size 315

Room controller optional optional optional -

Power supply optional, 230 V or 24 V optional, 230 V or 24 V 24 V -

Casing leakage class according to EN 1751

- - C (class 4 in HFB/G, HFB/I) C

Other options low-flow model, control unit low-flow model, control unit electronic reheat coil, external insulation, control unit

-

Encased controls yes yes no no

Ventilation Supply valves

Exhaust valves

Sauna valves

BOS ULE ULA ULC URH ULS URS

Area of use: Wall Wall Ceiling Ceiling Wall/ceiling Wall/ceiling Wall/ceiling

Sizes 100 and 125 100 and 125 100, 125, 160 and 200

100 and 125 100, 125, 160 and 200

100 and 125 100 and 125

Operation range (< 30 dB(A) 100 125 160 200

min

13 l/s/75 Pa

15 l/s/75 Pa

max

29 l/s/60 Pa

32 l/s/60 Pa

min

6 l/s/150 Pa

11 l/s/120 Pa

max

32 l/s/100 Pa

52 l/s/60 Pa

min

11 l/s/65 Pa

18 l/s/100 Pa

22 l/s/85 Pa

23 l/s/80 Pa

max

27 l/s/38 Pa

42 l/s/35 Pa

60 l/s/28 Pa

80 l/s/25 Pa

min

8 l/s/200 Pa

14 l/s/125 Pa

max

29 l/s/65 Pa

45 l/s/30 Pa

min

5 l/s/60 Pa

6 l/s/90 Pa

10 l/s/60 Pa

9 l/s/94 Pa

max

30 l/s/95 Pa

46 l/s/75 Pa

62 l/s/80 Pa

59 l/s/75 Pa

min

10 l/s/100 Pa

16 l/s/43 Pa

max

15 l/s/64 Pa

30 l/s/38 Pa

min

5 l/s/60 Pa

6 l/s/90 Pa

10 l/s/60 Pa

9 l/s/94 Pa

max

30 l/s/95 Pa

46 l/s/75 Pa

62 l/s/80 Pa

59 l/s/75 Pa

Airflow adjustment • • • • • • •

Flow pattern adjustment

• • • •

Installation-Straight to duct-With installation frame

• • ••

• •• • •

- The valves marked with an ‘x’ can also be used as a smoke damper (throttle) meeting requirement E7 of the National Building Code of Finland.

Fire valve FDV

Combined exhaust valve and fire damper for circular ducts. Type-approved unit compliant with the EN 1366-2 and EN 13501-3 standards. Fire-resistance class ES120/EIS15 for installations on lightweight plasterboard, lightweight concrete, concrete, and masonry walls. Fire-resistance class ES120/EIS30 on concrete slabs. Fuse-release temperature of 50, 72, or 100 °C. Other features identical to those of the URH valve.

Active chilled beam CBH

Combined cooling, heating, and supply-air unit for inconspicuous wall installation. An ideal system for buildings where good indoor environment and room-specific control are appreciated. Limited need for maintenance, thanks to the simple and hygienic operation. Various solutions to meet even demanding architectural requirements.

Concealed installation, Refurbishment

Mask plate

Ceiling

Induced air, h = 100 mm

2

4356

Page 9: Halton – Residential Ventilation System€¦ · Halton Central vacuum cleaning general benefits • Healthy - removal of hazardous micro dust (the air is filtered, then blown out

9

External diffuser EAD

Diffuser for roof installation for exhaust air. Blowing of air straight upward. Low height combined with aesthetically pleasing appearance. With diffuser structure in combination with the exhaust air, reduction in the amount of water entering the ventilation system. Sturdy, easy-open structure for smooth cleaning and maintenance. Connection sizes D = 125–1250 mm. Galvanised steel.

External louvre USS

External louvre for air intake and exhaust to prevent rain, snow, leaf, and animal ingress. Anti-rainwater-ingress efficiency of approx. 95% (USS/I). Operation based on special front-edge blade profile and side grooves. Grille and steel mesh section that are detachable from the outside. Blade depth of 65 mm, distance 50 mm, and free opening 50%. Availability of modular construction for large sizes. Available painted, in unfinished or anodised aluminium, or in stainless steel (AISI 316) and copper.

External intake louvre HLS

Labyrinth structure that is specially designed to prevent snow but also prevents rain, leaf, and animal ingress from intake air effectively. Maintenance-free operation, thanks to the open structure and suspended ceiling structure. Three types of model: outside, flat-against-wall, and container model. A large selection of size options and extensive customisability. Hot-galvanised and painted steel materials, or a special material for customer-specific needs.

Kitchen Ventilation DPI

A solution for high-efficiency kitchen extraction, the DPI is the result of all the expertise Halton has gained from ventilating many of the great restaurants and hotels of the world. Fit to grace any kitchen, it offers sharp lines, superb functionality, and a customisable appearance.

1

1

2

4 35

6

Page 10: Halton – Residential Ventilation System€¦ · Halton Central vacuum cleaning general benefits • Healthy - removal of hazardous micro dust (the air is filtered, then blown out

10

Page 11: Halton – Residential Ventilation System€¦ · Halton Central vacuum cleaning general benefits • Healthy - removal of hazardous micro dust (the air is filtered, then blown out

11

Acentralvacuumcleanerbringsanewkindofcomfort

tolivinginablockofflatsbyimprovingindoorairquality

and facilitating cleaning – comforts that have long been

available in detached houses. The system is easy to

install, particularly with modern prefabricated pipe

elements.

Acentralunitinitscompactsealedbodycanbe

positioned with ease. Halton offers services that extend

from design to installation and maintenance. We help

you to implement a reliable central vacuum-cleaning

system that is easy to design for the flats.

ProVac

Halton Central vacuum cleaning general benefits

•Healthy-removalofhazardousmicrodust(theairis

filtered, then blown out of the building)

•Clean-effectivedustremoval

•Silent-silentandsmell-freeoperation

•Efficient-morevacuumingpowerand20-30%

faster cleaning

•Economical-cleaningofindoorair,withless

cleaning of ventilation pipes and increased air-filter

service life

•Providingaddedpropertyvalue

- good for the value and desirability of the building

and its residential flats

Benefits of the Halton Central vacuum cleaning

•Energy-efficientoperation

-thecentralunitequippedwithinverteradjuststhe

power of the blower to the number of users

•Noblockagesinpipelines

-cleaningvalvesattheendofhorizontaltrunkpipes

with automatic pipe flushing feature

•Highdurability

- long service life

-lowmaintenanceandservicingrequirements

- heavy-duty side-channel turbine

-longfilterlife,ofupto12months

- central unit, inlet valves, and cleaning valves all

made of sturdy metal

- pipelines designed to withstand heavy use and

high underpressure

Central vacuum cleaning

Page 12: Halton – Residential Ventilation System€¦ · Halton Central vacuum cleaning general benefits • Healthy - removal of hazardous micro dust (the air is filtered, then blown out

12

65

4

3

2

1

Page 13: Halton – Residential Ventilation System€¦ · Halton Central vacuum cleaning general benefits • Healthy - removal of hazardous micro dust (the air is filtered, then blown out

13

Centralunitisonlocatedonthegroundfloor/cellarand

from there the suction piping is divided throughout the

building.Pipingistree-likewherebranchesaresmaller

thantrunkpipe;sizesarebetweenØ50–Ø110mm.

Pipingiseasytorouteinloweredceilings.Pipematerial

isPVCorgalvanizedsteeldependingonfireregulations.

Afirestopcollarisusedbetweenfirezones.Inletvalves

are located so all areas can easily be vacuumed with

8-12mvacuuminghose.Buildingswithmorethan20

flatsaredesignedwithmultiplecentralunits.Vacuumed

air is blown out of the building through the roof of the

building.

Designing a system

CVC inlet valve options

Front Flat Outside of wall

Installation Wall installation yes yes yes

Floor installation - yes (forced) -

Installation hole needed Ø 74 mm W 85 x H 94 mm -

Materials Painted steel yes yes (wall installation) yes

Brushed stainless steel yes yes yes

Opening method Key hook or turn key yes yes yes

Finger opening yes - -

CVC central unit, Halton Pro

Central unit for 1–6 or 1–3 simultaneous users, with inverter-controlled 12.5 or 5.5 kW turbine blower. Cyclone pre-separation and 8 m2 fine filter that discharges vacuumed particles to an 80 l plastic bag. Air compressor for automatic filter-cleaning and pipe-flushing. Alarm information and fieldbus connection options. All-in-one sturdy frame, W 1130 x H 1990 x D 700 mm.

ProVac system overview

1Central unit: 3–6 users per unit

2Main pipelines: Ø 75–110 mm

3Rinsing with flushing: Automatic rinsing of the pipelines with automatic cleaning of the pipelines

4Pipework for wall valves: Ø 51 mm

5Wall valves: Painted steel

6Exhaust pipe: Spiral welded steel, Ø 160 mm

Page 14: Halton – Residential Ventilation System€¦ · Halton Central vacuum cleaning general benefits • Healthy - removal of hazardous micro dust (the air is filtered, then blown out

14

Fire dampers for all applications

The Halton fire damper range is type approved and

compliant with the latest European EN 1366-2 and EN

13501-3 standards. All Fire Dampers are certified with

CE-Mark according to EN15650 providing oportunity to

use it anywhere within Europien Union. The range

consists of insulated EIS and non-insulated ES fire

dampers up to a fire-resistance period of 120 minutes.

When non-insulated products are used, additional

insulation may be applied to the ductwork for reaching

the insulation requirements set in the national building

code of certain countries.

The Halton range makes the design and installation of

fire dampers simple. All products are approved for use

in concrete, masonry, and lightweight walls and in

floors up to the stated fire rating. Products are also

installation-ready for all usage situations as delivered.

In sum, there is no need to specify installation details

for each damper. Ordering and storage are made

easy, and product pricing is transparent, without

installation accessories that create hidden costs. The

Halton fire damper range offers a sound, easy, and

efficient choice for the whole design and contracting

chain.

Fire-safety solutions

Page 15: Halton – Residential Ventilation System€¦ · Halton Central vacuum cleaning general benefits • Healthy - removal of hazardous micro dust (the air is filtered, then blown out

15

Fire dampers

EIS-fire dampers ES-fire damper

FDT FDI FDE

Conformity EN 1366-2,EN 13501-3

EN 1366-2,EN 13501-3

EN 1366-2,EN 13501-3

Connection Connection type rectangular or circular circular circular

Connection size [mm] H 200...1000W 200...2100D 630...1250

D 100...630 D 100...500

Classification Fire-resistance class EIS 60 EIS 60 ES 90

Flame and hot gas tightness (E) 60 60 120

Insulation (heat-transfer resistance) (I) 60 60 15

Gas and smoke tightness (S) 60 60 90

Installation Vertical installation in concrete or masonry wall

yes yes yes

Horizontal installation in concrete floor yes yes yes

Vertical installation in lightweight plasterboard wall

yes yes yes

Wall installation orientation horizontal or vertical horizontal or vertical horizontal or vertical

Accessories Optional limit for entering manual mode (microswitch)

yes yes yes

Optional safety mesh on actuator side or both sides

yes yes yes

Release type Spring release, manual adjustment yes yes yes

Spring release, electrical actuator 24 VDC/230V AC, fuse 72 °C

yes yes yes

Pneumatic release, manual adjustment yes yes yes

Electric release, 24 VDC/230 VAC manual adjustment

yes yes yes

Electromagnetic release, 24 VDC manual adjustment

yes yes yes

Fuse-temperature options for manual adjustment

50, 72, 100 °C 50, 72, 100 °C 50, 65, 72, 100,120, 150, 200 °C

Tightness Casing leakage class according to EN 1751 C C C

Maximum duct operating pressure 3300 Pa 3300 Pa 3300 Pa

1

2

1 2

Page 16: Halton – Residential Ventilation System€¦ · Halton Central vacuum cleaning general benefits • Healthy - removal of hazardous micro dust (the air is filtered, then blown out

16

Page 17: Halton – Residential Ventilation System€¦ · Halton Central vacuum cleaning general benefits • Healthy - removal of hazardous micro dust (the air is filtered, then blown out

17

Halton’s air-filtration products meet regulatory

requirements and standards, and they provide a safe,

high-quality indoor environment in an energy-efficient

manner. Halton’s extensive product range offers air-

filtration products and services for a wide range of

applications, from production facilities to offices and

hospitals and from laboratories to homes.

Filter materials

Glass-fibre-based filter materials are suitable for such

purposes as separation of particles in paint shops or

carpenter’s and metal workshops, whereas a synthetic

mat is used as a preliminary filter at many sites.

Coarse filters

Coarce (bag and panel) filters are intended for

removing the largest particles, such as sand and

pollen, from the air.

Fine filters

Fine filters (bag and panel) manufactured from

fibreglass efficiently remove bacteria and fine particles

from the air. They can also remove a considerable

proportion of the particles caused by traffic and

energy production. Halton’s fine filters are Eurovent-

certified.

EPA, HEPA, and ULPA filters

HEPA filters remove nearly 100% of the impurities in

the air. Filters of these types are used, for instance, in

hospitals and industrial cleanrooms.

Filter packages for ventilation devices in detached

houses

We also offer filter packages manufactured for

domestic use. The filters include a coarse mat and a

fine cassette or bag filter.

Safe and energy-efficient filtering of air

Page 18: Halton – Residential Ventilation System€¦ · Halton Central vacuum cleaning general benefits • Healthy - removal of hazardous micro dust (the air is filtered, then blown out

YIT

Page 19: Halton – Residential Ventilation System€¦ · Halton Central vacuum cleaning general benefits • Healthy - removal of hazardous micro dust (the air is filtered, then blown out

19

References

Skanska

Hartela

Page 20: Halton – Residential Ventilation System€¦ · Halton Central vacuum cleaning general benefits • Healthy - removal of hazardous micro dust (the air is filtered, then blown out

Halton – Enabling wellbeing in indoor environments

Halton is a specialist in indoor climate and indoor environment products, services and solutions. Halton’s aim is to create comfortable and safe indoor environments with energy-efficient and sustainable life cycle. Halton solutions range from public and commercial buildings to industry, commercial kitchen and restaurant applications. Halton is also one of the most recognized indoor climate solution providers for marine and offshore applications. Areas of expertise and product ranges cover air diffusion, airflow management, fire safety, kitchen ventilation, air purification and indoor environment management.

www.halton.com

Enabling Wellbeing