Hall effect current sensor 모바일용 · AC variable speed drives and servo motor drives Static...
Transcript of Hall effect current sensor 모바일용 · AC variable speed drives and servo motor drives Static...
00
30
10
20
50
40
05
25
55
35
4515
J&D is a market leader in current and voltage sensors.
Built with its advanced AI and IoT technology, J&D is launching products such as the
Outdoor Waterproof Rogowski Coil CT, the Split-Core Power Metering CT,
an Advanced Power Quality Meter, a Branch Circuit Power Meter
and a Wireless Distribution Transformer Monitoring System.
The brand new PQ-CT Series, which consists of the JPS Series Split-Core
CT and the JRFS-RM Series Rogowski coil CT, can be used for power
quality monitoring and highly accurate revenue grade metering for
both AC and DC current.
J&D's new products are the best solution for smart grid applications
such as MV / LV substations, power quality meters, energy meters,
branch circuit meters, PV monitoring, motor quality diagnostics,
Traction and data center,etc
CONTENTSFor Smart Industry
Measuring Principles
Applications
Closed-Loop Current Sensor
* JP-50/100
* JP-200
* JPC-200X
* JPC-300X
* JPC-500X
* JPC-1000X
* JPC-2000X
Open-Loop Current Sensor / Technology PQ-CT
* JHAO-XXXG(A/B) Series
* JHAO-XXXC(A/B) Series
* JHAO-XXXXD Series
* JM21XH-XXX-XXX Series
* JSXXXH-XXX Series
* JPSXXH Series
* JHAO-XXXXSD(A/B) Series
Closed-Loop Voltage Sensor
* JHVC-A25
Digital Voltage Sensor
* EVS30-XXXX-X Series
* EVS30A-XXXX Series
Checklist for Customers
04
05
06
08
09
10
12
14
16
18
20
21
22
23
24
26
28
29
30
32
34
The importance of Smart Industrial applications is increasing in order to save energy and cost.Smart Industrial applications are controlled by power loss and accurate regulation of electronic parameters such as current, voltage and power.J&D uses innovative technologies to ensure the high degree of reliability and safety that our customers require.J&D offers a comprehensive range of accurate, reliable and galvanically isolated devices to measure AC/DC current from 3A to 6000A and AC/DC voltage from 10V to 3000V by acrossing wide range of technologies.J&D CT are UL/CE marked in recognition of their electromagnetic compatibility and compliance to Safety standards.
Typical applications include
Power supplies for welding, medical, Elevators
Servo motor drives & Inverters
Uninterruptible power supplies (UPS)
PV monitoring
Pumps & fans control/monitoring
Traction & Trackside
Converters, Rectifiers
Solar / Photovoltaics
for Smart Industry
4
New Precision Hall effect Technology
5
Measuring Principles
IN VM
RL+VA
0VM
- VA
IN
+VA
0V
- VA
+ HT
- HT
+VA
- VA
0V
+
M
-
RMIS
VM
Measuring Principle of Isolation Amplifier TechnologyOur Isolation Amplier Technology Voltage Sensors - iSAST EVS series begins with an internal resistor network. This network measures DC Voltage by directly contacting both the Positive High Voltage (+HT) and the Negative High Voltage (-HT).This Voltage signal is transmitted to the secondary side of the sensor through an insulat-ed transformer that isolates the Primary High Voltage from the Secondary Low Voltage. The resulting signal is then converted through an amplier into either a current or a Voltage signal. Therefore the circuit converts a primary Voltage into a secondary current or Voltage that is proportional to the input.
J&D AC/DC CTs provide non-contact detection of AC/DC current.The AC/DC CTs have two types of split-core & solid-core design with various utility, high reliability & Cost-effective solution for precise current measurements.The rated current range is 5A to 6000A AC/DC and secondary output value is 4/5/10 V/333mV DC & 4-20 mA, Instantaneous AC/DC current.
Measuring Principle of Open-Loop Current TechnologyOpen-loop Hall eect technology creates magnetic ux from the input primary current and its magnetic ux couples a proportional low voltage, which amplify before being output.
Measuring Principle of Closed-Loop Current TechnologyThe secondary current is generated by transferring the proportional voltage of the hall sensor originated by the magnetic ux from the primary current.The feedback of the compensating current via the secondary winding closes the loop, where by this current is an exact representation of the primary current.
J&D AC/DC VT offers a comprehensive range of accurate, reliable and galvanically isolated devices to measure AC/DC voltage from 10V to 3000V across a range of technologies.
Measuring Principle of Closed-Loop Voltage TechnologyWhen a primary Voltage is applied to the input resistor Ri, the current Ip ows through the wire of the input W1 coil and generates a magnetic ux passing the Hall Sensor. The closed-loop feedback amplier used the Hall Voltage to generate a compensating current which is applied to the secondary winding W2 thereby creating the compensat-ing magnetizing ux. This current is exactly proportional to primary current Ip through Ri and the input Voltage Vm and as it ows through the output metering resistor RL it creates a voltage drop Vm which is proportional to the Primary Voltage Vm. Dependent on the ratio Ri/Rl you can get a wished voltage transfer ratio.
VM
RL+VA
0VM
- VA
NP W1
W2’1
W2’2
IP
VM
Ri
6
Applications
Battery SuppliedApplications
Static Convertersfor DC Motor Drives
1~3~
~-
M~IpConverter
1~ ~-
Field Rectier
I
1~3~
~-
IpCharger
3~~- M~
IMBattery Inverter
G~3~3~ ~
- ~-
IG ILVDC
IDCRectier or
InverterDC-Link PWM
Inverter
1~3~ 3~
~- ~
- M~IL IMVDC
IDCRectier or
InverterDC-Link PWM
InverterAC Variable Speed Drives
and Servo Motor Drives
1~3~
~-
Battery~-
IVDC
IDCCharger DC-Link Inverter
UninterruptiblePower Supplies (UPS)
1~3~
~-
-
I
PWMInverter
-IVDC
IDCInput
RectierDC-Link Output
Rectier
AC
DCPower Supplies forWelding Applications
1~3~
~-
-
PWMInverter
-IVDC
IDCInput
RectierDC-Link Output
Rectier
Switched ModePower Supplies (SMPS)
7
PCBMounting
8
Closed-Loop Current SensorJP-50/100
14.5
7.3
6.85
54.5
37
15.223
27.8
15.6
0.5
7.3
5.2
Unless otherwise specied,tolerances shall be ±0.5mm
Closed loop (compensated) current transducer using the Hall eectPrinted circuit board mounting Insulated plastic case recognized according to UL 94-V0.
IPIS Rm
0V
+Vc
–Vc
M
+
–
Features
Electrical Properties
Dimension Connection
Unit : mm [inch]
Primary nominal currentMeasuring resistance
Rated output current
Output current accuracyOset currentOutput linearity
Vcc=±12V @ ±50A : 60Ω ~ 95Ω@ ±60A : 60Ω
Vcc=±15V @ ±50A : 135Ω ~ 155Ω @ ±55A : 135Ω
50A
50mA( Turn ratio 1:1000)
≤ ±0.1mA (at If=0A)
Model JP-50
≤ ±0.15%(at If )±12V ±5% ~ ±15V ±5% (output current is restricted by Vcc)Power supply voltage
≤ 1μS(at di/dt=If/μs)Response time
≤ ± 0.01%/˚C(Without TcIof )Thermal drift of gain≤ ± 0.5mAThermal drift of oset
≤ 0.3mA (at If=0A → If → If=0A)Hysteresis error
IfRL
TCIO
IO
tr
IoH
AC3000V for 1 minute (Sensing current 0.5mA)inside of through hole ⇔ terminal
Insulation voltage VD
V
TCIOf
≥500MΩ (at DC500V) inside of through hole ⇔ terminalInsulation resistance-40˚C ~ +85˚CAmbient Operating temperature-40˚C ~ +90˚CAmbient storage temperature
80Ω(@Ta=70˚C)85Ω(@Ta=85˚C)
Vcc=±12V @ ±100A : 0Ω ~ 42Ω @ ±120A : 0Ω ~ 14Ω
Vcc=±15V @ ±100A : 20Ω ~ 102Ω @ ±150A : 20Ω ~ 25Ω
100A
50mA( Turn ratio 1:2000)
≤ ±0.2mA (at If=0A)±0.45 (±15V, +25˚C ) ±0.65 (±15V, +25˚C )
JP-100
120Ω(@Ta=70˚C)128Ω(@Ta=85˚C)
Secondary coil resistance
TA
RIS
RS
TS
Iof
εL
VCC
DC…200kHz (-1 dB)Frequency characteristics f
PCBMounting
Unit : mm [inch]
Closed-Loop Current SensorJP-200
Closed loop (compensated) current transducer using the Hall eectPrinted circuit board mounting Insulated plastic case recognized according to UL 94-V0.
Electrical Properties
Dimension Connection
9
Features
48.613 18
0.6
11.612.7
12.75.1
13.95.1
33.6
0.511
4
5.5
40.64
6.95 8.89
Ø1.75
15.84
IP IS Rm0V
+Vc
–Vc
NC
M
+
–
Unless otherwise specied,tolerances shall be ±0.5mm
Primary nominal currentMeasuring resistance
Rated output current
Output current accuracyOset currentOutput linearity
Vcc=±12V @ ±200A : 0Ω ~ 26ΩVcc=±12V @ ±250A : 0Ω ~ 4ΩVcc=±15V @ ±200A : 0Ω ~ 56ΩVcc=±15V @ ±300A : 0Ω ~ 8Ω
200A
100mA ( Turn ratio 1:2000)
≤ ±0.2mA (at If=0A)
Model JP-200
≤ ±0.15%(at If )±12V ±5% ~ ±15V ±5% (Rated output current is restricted by Vcc)Power supply voltage
≤ 1μS(at di/dt=If/μs)Response time
≤ ± 0.01%/˚C(Without TcIof )Thermal drift of gain≤ ± 0.5mAThermal drift of oset
≤ 0.3mA (at If=0A → If → If=0A)Hysteresis error
IfRL
TCIO
IO
tr
IoH
AC3000V for 1 minute (Sensing current 0.5mA)inside of through hole ⇔ terminal
Insulation voltage VD
V
TCIOf
≥500MΩ (at DC500V) inside of through hole ⇔ terminalInsulation resistance-40˚C ~ +85˚CAmbient Operating temperature-40˚C ~ +90˚CAmbient storage temperature
76Ω(@Ta=70˚C)80Ω(@Ta=85˚C)
±0.4 (±15V, +25˚C )
Secondary coil resistance
TA
RIS
RS
TS
Iof
εL
VCC
DC…100kHz (-1 dB)Frequency characteristics f
PanelMounting
VD
10
Closed-Loop Current SensorJPC-200X
Applications
Specification
Features
AdvantagesFor the electronic measurement of currents : AC/DC current sensor, JPC series has good stability in high currents anda highly insulated primary and secondary.
AC variable speed drives and servo motor drivesStatic converters for DC motor drivesBattery supplied applicationsUninterruptible Power Supplies (UPS)Switched Mode Power Supplies (SMPS)Power supplies for welding applications.
Closed loop (compensated) current transducer using the Hall eectInsulated plastic case recognized according to UL 94-V0Panel mounting
Excellent accuracyVery good linearity
Low temperature driftOptimized response timeWide frequency bandwidthNo insertion lossesHigh immunity to external interferenceCurrent overload capability.
MODEL
ConnectorPrimary nominal current rms
Secondary nominal current rms
Current consumption @ ± 15 V Supply voltage (+/-5%) Conversion ratio
Overall accuracyLinearity error
Insulation voltage
Reaction time to 10 % of IPN stepReaction time to 90 % of IPN stepdi/dt accurately followedFrequency bandwidth (- 3 dB) Ambient Operating temperatureAmbient storage temperatureSecondary coil resistance
Primary current, measuring rangeMeasuring resistance
0 .. ± 420
1001 : 2000
± 12 .. 15
± 0.517 + IS
< 0.1Max. ± 0.2
AC 3500V / 1min.
< 500< 1 (With a di/dt of 100 A/µs.)
> 100DC .. 100
- 40 .. + 85- 40 .. + 90
33 (@Ta=70˚C) / 35 (@Ta=85˚C)
± 12V Ta=70˚C : 0 ~ 71 Ta=70˚C : 0 ~ 14
Ta=85˚C : 0 ~ 69Ta=85˚C : 0 ~ 12
± 15V Ta=70˚C : 0 ~ 100Ta=70˚C : 0 ~ 28
@ ± 200A@ ± 420A@ ± 200A@ ± 420A
Ta=85˚C : 23 ~ 98Ta=85˚C : 23 ~ 26
JPC-200F
39-28-8040[5566-04A-210] Molex200
-A
V
%%
mAMax. ± 0.1(@ IP M, after an overload of 3 x IPN)mA
Temperature variation Typ. ± 0.12 , Max. ± 0.4 (-45˚C...+85˚C)mAns
AΩ
mA-
kHz˚C˚CΩ
Mass 78g
Standards EN 50178: 1997 / IEC 61010-1-
mA
JPC-200T
38-00-6293[6410-03C(102)] MolexSPEC
PanelMounting
53.8
4.3
61
12
19.5
1.2
12
24
24.5
4
4
53.8
4.3
6112
19.5
1.2
12
24
24.5
4
4
11
Closed-Loop Current SensorJPC-200X
Dimensions(mm)
3
2
4
1
Connector
Detail AConnector
Molex
Manufacturer
39-28-8040
Part Number
5566-04A-210
Old Part Number
Primary through-hole Ø 15.5 mm
IP
IS Rm0V
+Vc
–Vc
NC
2134
M
+
–
3
2
1
Connector
Terminal No.
Detail B
Connector
Molex
Manufacturer
38-00-6293
Part Number
6410-03C (102)
Old Part Number
Primary through-hole Ø 15.5 mm
IP
IS Rm0V
+Vc
–Vc
213
M
+
–
JPC-200T
JPC-200F
2.5 26.5
51
41.3
49
R7.8
15.1
7.3
41.3
4.3
39.5
A
A
A
49
2.5 26.5
51
41.3
R7.8
15.1
7.3
41.3
4.3
39.5
B
A
A
PanelMounting
12
Closed-Loop Current SensorJPC-300X
Applications
Specification
Features
Advantages
For the electronic measurement of currents : AC/DC current sensor, JPC series has good stability in high currents anda highly insulated primary and secondary.
AC variable speed drives and servo motor drivesStatic converters for DC motor drivesBattery supplied applicationsUninterruptible Power Supplies (UPS)Switched Mode Power Supplies (SMPS)Power supplies for welding applications.
Closed loop (compensated) current transducer using
Insulated plastic case recognized according to UL 94-V0Panel mounting
Excellent accuracyVery good linearity
Low temperature driftOptimized response timeWide frequency bandwidthNo insertion lossesHigh immunity to external interferenceCurrent overload capability.
MODEL
ConnectorPrimary nominal current rms
Secondary nominal current rms
Current consumption @ ± 15 V Supply voltage (+ 5 %) Conversion ratio
Overall accuracyLinearity error
Temperature variationReaction time to 10 % of IPN stepReaction time to 90 % of IPN stepdi/dt accurately followedFrequency bandwidth (- 1 dB) Ambient Operating temperatureAmbient storage temperatureSecondary coil resistance
Primary current, measuring rangeMeasuring resistance @
0 .. ± 500
1001 : 3000
± 12 .. 20
± 0.526(@ ±20V) + IS
< 0.1Max. ± 0.2
Typ. ± 0.2, Max. ± 0.7 (- 40˚C .. + 85˚C) / Typ. ± 0.1 , Max. ± 0.3 (- 10˚C .. + 70˚C)
< 500< 1 (With a di/dt of 100 A/µs.)
> 100DC .. 100
- 40 .. + 85- 40 .. + 85
30 (@Ta=70˚C) / 32 (@Ta=85˚C)
± 12V Ta=70˚C : 0 ~ 37 Ta=70˚C : 0 ~ 10
Ta=85˚C : 0 ~ 35Ta=85˚C : 0 ~ 8
± 15V Ta=70˚C : 0 ~ 56Ta=70˚C : 0 ~ 21
@ ± 300A@ ± 500A@ ± 300A@ ± 500A
Ta=85˚C : 0 ~ 54Ta=85˚C : 0 ~ 19
± 20V Ta=70˚C : 0 ~ 88Ta=70˚C : 0 ~ 40
@ ± 300A@ ± 500A
Ta=85˚C : 0 ~ 86Ta=85˚C : 0 ~ 38
JPC-300F
39-28-8040[5566-04A-210] Molex300
-A
V
%%
mAMax. ± 0.2 (@ IP M, after an overload of 3 x IPN)mA
mAns
AΩ
mA-
kHz˚C˚CΩ
Mass 95g
Standards EN 50178: 1997 / IEC 61010-1-
mA
JPC-300T
38-00-6293[6410-03C(102)] MolexSPEC
VDInsulation voltage AC 3800V / 1min.
PanelMounting
13
Closed-Loop Current SensorJPC-300X
Dimensions(mm)
Connector
Detail B
1
2
3
Connector
Molex
Manufacturer
38-00-6293
Part Number
6410-03C (102)
Old Part Number
Primary through-hole Ø 20.1 mm
IP
IS Rm0V
+Vc
–Vc
213
M
+
–
JPC-300T
JPC-300F
Current Direction
A
Connector
Detail A
3
2
4
1
Connector
Molex
Manufacturer
39-28-8040
Part Number
5566-04A-210
Old Part Number
Primary through-hole Ø 20.1 mm
IP
IS Rm0V
+Vc
–Vc
NC
2134
M
+
–
46
46
4.3
54
20.2
R10
56.5
29.5
10
3
44
A
A
60
68
1313
26.3
18.5
1.2
10
26.3
5
26
46
46
4.3
54
20.2
R10
56.5
29.5
10
3
44
A
A
60
68
1313
26.3
18.5
1.2
10
26.3
5
26
B
PanelMounting
14
Specification
Closed-Loop Current SensorJPC-500X
Applications Features
Advantages
AC variable speed drives and servo motor drivesStatic converters for DC motor drivesBattery supplied applicationsUninterruptible Power Supplies (UPS)Switched Mode Power Supplies (SMPS)Power supplies for welding applications.
For the electronic measurement of currents : AC/DC current sensor, JPC series has good stability in high currents anda highly insulated primary and secondary.
Closed loop (compensated) current transducer using the Hall eectInsulated plastic case recognized according to UL 94-V0Panel mounting
Excellent accuracyVery good linearityLow temperature driftOptimized response timeWide frequency bandwidthNo insertion lossesHigh immunity to external interferenceCurrent overload capability.
MODEL
ConnectorPrimary nominal current rms
Secondary nominal current rms
Current consumption @ ± 15 V Supply voltage (+ 5 %) Conversion ratio
Overall accuracyLinearity errorOset current
Temperature variationReaction time to 90 % of IPN stepdi/dt accurately followedFrequency bandwidth (- 1 dB) Ambient Operating temperatureAmbient storage temperatureSecondary coil resistance
Primary current, measuring rangeMeasuring resistance @
0 .. ± 800
1001 : 5000
± 15 .. 24
± 0.624(@ ±18V) + IS
< 0.1Max. ± 0.4
Typ. ± 0.1, Max. ± 0.4 (- 40˚C .. + 70˚C)< 1 (With a di/dt of 100 A/µs.)
> 100DC .. 100
- 40 .. + 70- 40 .. + 85
70 (@Ta=70˚C)
± 15V 0 ~ 60 0 ~ 11± 18V 0 ~ 92 0 ~ 30
@ ± 500A @ ± 800A@ ± 500A @ ± 800A
± 24V 5 ~ 149 5 ~ 65@ ± 500A @ ± 800A
JPC-500F
39-28-8040[5566-04A-210] Molex500
-A
V
%%
mA
Magnetic oset current Max. ± 0.2 (@ IP = 0 and specied RM, after an overload of 3 x IPN)mA
A/μs
mA
AΩ
mA
μs
-
kHz˚C˚CΩ
Mass 230g
Standards EN 50178: 1997 / IEC 61010-1-
mA
JPC-500T
38-00-6293[6410-03C(102)] MolexSPEC
VDInsulation voltage AC 3800V / 1min.
PanelMounting
15
Dimensions(mm)
Closed-Loop Current SensorJPC-500X
Primary through-hole Ø 30.2 mm
Connector
Molex
Manufacturer
39-28-8040
Part Number
5566-04A-210
Old Part Number
4
1
2
3
Connector
Detail A
IP
IS Rm0V
+Vc
–Vc
NC
3421
M
+
–
Primary through-hole Ø 30.2 mm
Connector
Molex
Manufacturer
38-00-6293
Part Number
6410-03C (102)
Old Part Number
3
2
1
Connector
Terminal No.
Detail B
IP
IS Rm0V
+Vc
–Vc
213
M
+
–
JPC-500T
JPC-500F
R15.1
1030.2
4.3
5658
70
A
A
16
77
80
89
6-4.3
15.5
31
31.5
18.5
5
31.5
1.5
2931
A
R15.1
1030.2
4.3
5658
70
A
A
16
77
80
89
6-4.3
15.5
31
31.5
18.5
5
31.5
1.5
2931
B
PanelMounting
16
Specification
Closed-Loop Current SensorJPC-1000X
Applications Features
AdvantagesFor the electronic measurement of currents : AC/DC current sensor, JPC series has good stability in high currents anda highly insulated primary and secondary.
AC variable speed drives and servo motor drivesStatic converters for DC motor drivesBattery supplied applicationsUninterruptible Power Supplies (UPS)Switched Mode Power Supplies (SMPS)Power supplies for welding applications.
Closed Loop (compensated) current transducer using the Hall eectInsulated plastic case recognized according to UL 94-V0Panel mounting
Excellent accuracyVery good linearityLow temperature driftOptimized response timeWide frequency bandwidthNo insertion lossesHigh immunity to external interferenceCurrent overload capability.
MODEL
ConnectorPrimary nominal current rms
Secondary nominal current rms
Current consumption ( ± 1mV )Supply voltage (+ 5 %) Conversion ratio
Overall accuracyLinearity errorOset current
Temperature variationReaction time to 90 % of IPN stepdi/dt accurately followedFrequency bandwidth (- 1 dB) Ambient Operating temperatureAmbient storage temperatureSecondary coil resistance
Primary current, measuring rangeMeasuring resistance
0 .. ± 1500
2001 : 5000
± 15 .. 24
± 0.428(@ ±24V) + IS
< 0.1Max. ± 0.4
Typ. ± 0.3, Max. ± 0.5 (- 10˚C .. + 85˚C) / Max. ± 0.8 (- 40˚C .. - 10˚C)< 1 (With a di/dt of 100 A/µs.)
> 100DC .. 150
- 40 .. + 85- 45 .. + 100
48 (@Ta=70˚C) / 51 (@Ta=85˚C)
± 15V Ta=70˚C : 0 ~ 18 Ta=70˚C : 0 ~ 7
Ta=85˚C : 0 ~ 15Ta=85˚C : 0 ~ 4
± 24V Ta=70˚C : 5 ~ 60.5Ta=70˚C : 5 ~ 24
@ ± 1000A@ ± 1200A@ ± 1000A@ ± 1500A
Ta=85˚C : 10 ~ 57.5Ta=85˚C : 10 ~ 21
JPC-1000F
39-28-8040[5566-04a-210] Molex1000
-A
V
%%
mA
Magnetic oset current Max. ± 0.2(@ IP = 0 and specied RM, after an overload of 3 x IPN)mAInsulation voltage AC 3800V / 1min.VD
A/μs
mA
AΩ
mA
μs
-
kHz˚C˚CΩ
Mass 550g
Standards EN 50178: 1997 / IEC 61010-1-
mA
JPC-1000T
38-00-6293[6410-03c(102)] MolexSPEC
PanelMounting
17
Closed-Loop Current SensorJPC-1000X
Dimensions(mm)
Primary through-hole 40.5 x 13 mm or Ø 38 mm
Connector
Molex
Manufacturer
38-00-6293
Part Number
6410-03C (102)
Old Part Number
B
3
2
1
Connector
Terminal No.
Detail B
IP
IS Rm0V
+Vc
–Vc
213
M
+
–
JPC-1000T
JPC-1000F
A
4
1
2
3
Connector
Detail A
Primary through-hole 40.5 x 13 mm or Ø 38 mm
Connector
Molex
Manufacturer
39-28-8040
Part Number
5566-04A-210
Old Part Number
IP
IS Rm0V
+Vc
–Vc
NC
3421
M
+
–
5.3
7994
13.5
40.5
R19.25
79
3.548
77
A
A
34.5
100
110
19
17
4-4.3
2- 5.3
34
19.5
95
1.5
3434.5
431.5
5.3
7994
13.5
40.5
R19.25
79
3.548
77
A
A
34.5
100
110
19
17
4-4.3
2- 5.3
34
19.5
95
1.5
3434.5
431.5
PanelMounting
18
Closed-Loop Current SensorJPC-2000X
For the electronic measurement of currents : AC/DC current sensor, JPC series has good stability in high currents anda highly insulated primary and secondary.
AC variable speed drives and servo motor drivesStatic converters for DC motor drivesBattery supplied applicationsUninterruptible Power Supplies (UPS)Switched Mode Power Supplies (SMPS)Power supplies for welding applications.
Closed loop (compensated) current transducer using the Hall eectInsulated plastic case recognized according to UL 94-V0 Panel mounting
Excellent accuracyVery good linearityLow temperature driftOptimized response timeWide frequency bandwidthNo insertion lossesHigh immunity to external interferenceCurrent overload capability.
MODEL
ConnectorPrimary nominal current rms
Secondary nominal current rms
Current consumption ( ± 1mV )Supply voltage (+ 5 %) Conversion ratio
Overall accuracyLinearity errorOset current
Temperature variationReaction time to 90 % of IPN stepdi/dt accurately followedFrequency bandwidth (- 1 dB) Ambient Operating temperatureAmbient storage temperatureSecondary coil resistance
Primary current, measuring rangeMeasuring resistance
0 .. ± 3000
4001 : 5000
± 15 .. 24
± 0.333(@ ±24V) + IS
< 0.1Max. ± 0.5
Typ. ± 0.2, Max. ± 0.5 (- 25˚C .. + 85˚C) / Max. ± 1.5 (- 40˚C .. - 25˚C)< 1 (With a di/dt of 100 A/µs.)
> 50DC .. 100
- 40 .. + 85- 50 .. + 90
25 (@Ta=70˚C) / 26 (@Ta=85˚C)
± 15V Ta=70˚C : 0 ~ 8 Ta=70˚C : 0 ~ 5
Ta=85˚C : 0 ~ 7Ta=85˚C : 0 ~ 4
± 24VTa=70˚C : --------Ta=70˚C : 5 ~ 11
@ ± 2000A@ ± 2200A
@ ± 2800A@ ± 3000A
Ta=85˚C : 13 ~ 13Ta=70˚C : 5 ~ 29@ ± 2000A Ta=85˚C : 13 ~ 28
Ta=85˚C : ---------
JPC-2000F
39-28-8040[5566-04a-210] Molex2000
-A
V
%%
mA
Magnetic oset current Max. ± 0.2(@ IP = 0 and specied RM, after an overload of 3 x IPN)mA
Insulation voltage AC 6000V / 1min.VD
A/μs
mA
AΩ
mA
μs
-
kHz˚C˚CΩ
Mass 1.5kg
Standards EN 50178: 1997 / IEC 61010-1-
mA
JPC-2000T
38-00-6293[6410-03c(102)] MolexSPEC
Applications Features
Advantages
Specification
PanelMounting
19
Closed-Loop Current SensorJPC-2000X
Dimensions(mm)
Primary through-hole 60.5 x 20.5 mm or Ø max 57 mm
Connector
Molex
Manufacturer
38-00-6293
Part Number
6410-03C (102)
Old Part Number Detail A3
2
1
Connector
Terminal No.
Detail B
IP
IS Rm0V
+Vc
–Vc
213
M
+
–
JPC-2000T
JPC-2000F
Primary through-hole 60.5 x 20.5 mm or Ø max 57 mm
Connector
Molex
Manufacturer
39-28-8040
Part Number
5566-04A-210
Old Part Number
4
1
2
3
Connector
Detail A
IP
IS Rm0V
+Vc
–Vc
NC
3421
M
+
–
6.5
103.5
135
20.5
60.5
103.5
R28.75
4 67.5
A
A
A
185252.5
2.5
134
5
152
6.5
30
170
11
52 52.5
18.5
6.5
103.5
135
20.5
60.5
103.5
R28.75
4 67.5
A
A
185252.5
2.5
134
5
152
6.5
30
170
11
52 52.5
18.5
B
PanelMounting
20
Open-Loop Current SensorsJHAO-XXXG(A/B) Series
* Sux(X)=A/B
1
2
3
4
+VCC
VOUT
RL=10kΩ
GND
-VCC
Core=Silicon steel plate
1Terminal PinFunction + 15V
2– 15V
3Output
40 V
Panel mountingIndustrial temperature rangeUL94-V0 complianceCE and RoHS available
MODEL
Rating currentSaturation current
Output voltage
Output linearityPower supply
Di/dt response timeOutput temperature
character
Operating ConditionStorage Condition
Oset voltage
Insulationwithstand voltage
±4 V, 1% at rated current RL=10KΩ
JHAO-050G(X)
50A150AT
JHAO-075G(X)
75A225AT
JHAO-100G(X)
100A300AT
JHAO-150G(X)
150A450AT
JHAO-200G(X)
200A600AT
JHAO-300G(X)
300A
JHAO-400G(X)
400A
JHAO-500G(X)
500A
JHAO-600G(X)
600A900AT
±30 mV max Less than ±50 mV max±15 mV max
3 μ sec (Typ.) at di/dt = F.S/μ Sec.
± 0.1% / °C (Typ.)
AC 2500V / 1min.
±1% rated current±15 V (±5%) 20mA
Oset voltagetemperature character
± 2mV/°C
Hysteresiserror
30mV Less than 30mV
± 1mV / °C (Typ.)
25mV(IF=F.S) Less than 25mV
Insulation resistance DC 500V / 500MΩ max
Frequency bandwidth 20kHz-15°C~+80°C-15°C~+85°C
Specification
Dimension Connection
Unit : mm [inch]
40
30
10.3
20.3
204.75Ø2.5
Ø4.6
32.5
20
3025
4.7
MOLEX5045-04AG
orGEOYOUNG
LPH01-041234
→If
JHAO-XXXGB40
30
10.3
20.3
204.75Ø2.5
Ø4.6
32.5
20
3025
4.7
MOLEX5045-04AG
orGEOYOUNG
LPH01-04
1234
→If
JHAO-XXXGA
Features
PanelMounting
21
Open-Loop Current SensorsJHAO-XXXC(A/B) Series
JHAO-XXXCB48
Ø30
78
54
10
61 20.5
MOLEX5045-04AG
orGEOYOUNG
LPH01-04
2-Ø4.5
20.5 9.
8
53.5
17
7.8
1 2 3 4
→If
JHAO-XXXCA
→40
2-Ø4.5
20.5
45.5
17
Ø22
70
50
If
53
MOLEX5045-04AG
orGEOYOUNG
LPH01-04
10
1 2 3 4
9.8
7.8
1
2
3
4
+VCC
VOUT
RL=10kΩ
GND
-VCC
Core=Silicon steel plate
1Terminal PinFunction + 15V
2– 15V
3Output
40 V
Panel mountingIndustrial temperature rangeDesigned for round-wire, output connector typeUL94-V0 complianceCE and RoHS availableTwo dierent size (A : 22Ø / B : 30Ø)
MODEL
Rating currentSaturation current
Output voltage
Output linearityPower supply
Di/dt response timeOutput temperature
character
Operating ConditionStorage Condition
Oset voltage
Insulationwithstand voltage
±4 V, 1% at rated current RL=10KΩ
JHAO-050C(X)
50A150AT
JHAO-075C(X)
75A225AT
JHAO-100C(X)
100A300AT
JHAO-150C(X)
150A450AT
JHAO-200C(X)
200A600AT
JHAO-300C(X)
300A
JHAO-400C(X)
400A
JHAO-500C(X)
500A
JHAO-600C(X)
600A900AT
±30 mV max Less than ±50 mV max±15 mV max
3 μ sec (Typ.) at di/dt = F.S/μ Sec.
± 0.1% / °C (Typ.)
AC 2500V / 1min.
±1% rated current±15 V (±5%) 20mA
Oset voltagetemperature character
± 2mV/°C
Hysteresiserror
30mV Less than 30mV
± 1mV / °C (Typ.)
25mV(IF=F.S) Less than 25mV
Insulation resistance DC 500V / 500MΩ max-15°C~+80°C-15°C~+85°C
Specification
Dimension Connection
Unit : mm [inch]
* Sux(X)=A/B
Features
PanelMounting
22
Connection
Open-Loop Current SensorsJHAO-XXXXD Series
Features
Specification
Dimensions(unit : mm)
1
2
3
4
+V CC
V OUT
R L=10kΩ
GND
-V CC
Core=Silicon steel plate
1Terminal PinFunction + 15V
2– 15V
3Output
40 V
Panel mountingIndustrial temperature rangeUL94V0 complianceCE and RoHS available
MODEL
Rating currentSaturation current
Output voltage
Output linearityPower supply
Di/dt response timeOutput temperature
character
Operating ConditionStorage Condition
Oset voltage
Insulationwithstand voltage
±4 V, 1% at rated current RL=10KΩ
JHAO-200D(X)±200A±600A
JHAO-400D(X)±400A
±1200A
JHAO-500D(X)±500A
±1500A
JHAO-600D(X)±600A
±1800A
JHAO-750D(X)±750A
±2250A
JHAO-800D(X)±800A
JHAO-1000D(X)±1000A
JHAO-1200D(X)±1200A
JHAO-1500D(X)±1500A
±2400A ±3000A
±30 mV
7 μ sec (Typ.) at di/dt = F.S/μ Sec.
± 0.1% / °C (Typ.)
AC 2500V / 1min.
±1% rated current±15 V (±5%)
Oset voltagetemperature character
Hysteresiserror
± 1mV / °C (Typ.)
25mV(IF=F.S) Less than 25mV
Insulation resistance DC 500V / 500MΩ max-40°C ~ +105°C-40°C ~ +125°C
* Sux(X)=A/B
63
53 6530.5
42.5
19.5 8.25
70.5
89
78.542
142412
5
5
3843
1
4
OFS
R2.3
Ø4.6
Ø4.6
24
43
6 612
23
Open-Loop Current SensorsJM21XH-XXX-XXX Series
28.4
9
95
80.5
4.7 7.2
19.7
2.5
• Dimensions (unit : mm)
Mount the bracket on the rail and install current transformer
DIN RAIL MOUNTING51
.5
46
7035
35
24.27
• Dimensions (unit : mm)
Tighten screws on the hole to mount bracket and install current transformer
PANEL MOUNTING
- +
70 60
64228
O G
2840.3
23.8
14.5 2000 ± 50AWG #18
8
Relay cable(common)(attached with CT)
Power supply: 24VDC
O : OutputG : GND
Part-NO. : 56002(red)
Specification Acc essory O ption
Dimensions (unit : mm)
Split-core current transducer for the electronic measurement of DC or AC wave-form currents, with galvanic isolation between the primary circuit and the Split-core current transducer for the electronic measurement of DC or AC wave-form currents, with galvanic isolation between the primary circuit and the secondary circuit (measurement). True-RMS outputs proportional to theprimary current: Either 0-5V DC or Active Current Source 4-20mA DC.
ㆍAutomation and SupervisionㆍSafety and Condition MonitoringㆍHVAC & PumpsㆍRefrigerationㆍSmall Industrial MotorsㆍFansㆍLighting
ApplicationsㆍCurrent transformer and RMS
circuit in a single case
ㆍChoice of primary current ranges: 5 to 250A RMS
ㆍChoice of standard output types: 4-20mA, 0-5V
ㆍAccuracy: <2% of nominal primary current
ㆍBandwidth: 1kHz
Main characteristicsㆍHigh isolation between primary
and secondary circuitsㆍCompact caseㆍ
ㆍEasy installation
AdvantagesㆍTrue-RMS
(Bipolar DC in => Unipolar DC out) ㆍActive 0-5V DC output or
ㆍActive 4-20mA output
ㆍSingle power supply (24V)
ㆍOperating range: -20°C to +60°CㆍIsolation test voltage :
3.5kV RMS / 50Hz / 1minㆍSensing aperture :
21mmㆍUL94-V0 recognized materials
Features
AC/DC (INPUT) DC(OUTPUT)
Rated Current (A) 5, 10, 20, 25, 50, 75, 100, 150, 200, 250
Linear DC voltage output (True-RMS)
Active Current Source output (True-RMS)
Model Output Electrical Data
JM21XH-XXX-V
JM21XH-XXX-RMS
0-5V DC
4-20mA DC
Split CorePanel
Din Rail Mounting
Split CoreOn PrimaryFastening
24
One touch clamp structureIsolation measurement± 15V(25mA) power supply
How to use
Core’s hysteresis occurs O point variation in proportion to its volume after over current. Output value includes each variation points so we recommend that actual range as over 5% space than rating, not over max current consecutively.
MODEL
Rating currentSaturation current
Output voltage
Output linearityPower supply
di/dt response timeOutput temperature
character
Operating ConditionStorage Condition
Insulationwithstand voltage
±4 V, 1% at rated current RL=10KΩ
JS10NH- 005
5A7.5AT
JS10NH- 010
10A15AT
JS10NH- 015
15A22.5AT
JS10NH- 020
20A30AT
JS10NH- 025
25A37.5AT
JS10NH- 050
50A75AT
75A112.5AT
JS16NH- 005
JS16NH- 010
JS16NH- 015
JS16NH- 020
JS16NH- 025
JS16NH- 050
JS16NH- 075
JS16NH- 100
100A
JS24NH- 200
200A
JS24SH- 250
250A150AT 250AT
JS24NH- 150
150A225AT 625AT
JS24SH- 300
300A625AT
JS36SH- 500
500A625AT
JS36SH- 400
400A625AT
±20 mV max
3 μ sec (Typ.) at di/dt = F.S/μ Sec.
± 0.2% / °C (Typ.) ± 0.1% / °C (Typ.)
AC 1500V / 1min.
±1% rated current±15 V (±5%) 25mA
Insulation resistance DC 500V / 500MΩ max-25°C~+75°C, 85 % RH non-condensing-35°C~+90°C, 85 % RH non-condensing
Noise level±30 mV max Less than
< 20mVp-p < 10mVp-p
3 4
1 2
P2P1
Features
Specification
Caution
JS10 / 16 / 24 / 36 XH Hall Sensor series, applying with accurate laminating core split technology and Open Loop technology iSAST OPEN HCS, JSXXXH Series designed for strong durability and improves both existed error in low current and error occurred by ‘external vibration and shock’ to minimize tolerance on cutting cross section of core. As compact one-touch split structure, it oers best solution for security and fast installation on high frequency monitoring device instead of cutting power line. Rated current is DC5A-500A, it satises with accura-cy 1.0 and it certies with security accreditation IEC61010-1, UL61010-1 and EN61010-1 as ocial document.
JS10 / 16 / 24 / 36 XH Hall Sensor series, applying with accurate laminating core split technology and Open Loop technology iSAST OPEN HCS, JSXXXH Series designed for strong durability and improves both existed error in low current and error occurred by ‘external vibration and shock’ to minimize tolerance on cutting cross section of core. As compact one-touch split structure, it oers best solution for security and fast installation on high frequency monitoring device instead of cutting power line. Rated current is DC5A-500A, it satises with accura-cy 1.0 and it certies with security accreditation IEC61010-1, UL61010-1 and EN61010-1 as ocial document.
Open-Loop Current SensorsJSXXXH-XXX Series
Split CoreOn
PrimaryFastening
25
Open-Loop Current SensorsJSXXXH-XXX Series
COM INPUT
–15V +15V OV
(COM)
10A/div
1V/div
10A/div
1V/div
12
8
4
0
-4
-8
-12-150 -100 -50 0 50 100 150
(V)
lo (A)
(lo=5A)(lo=5A)
[Hz]
(mV)
10 100 1000 104 105
0
200
400
600
800
1000
1200
1400
Unit : mm
Model
J S 1 0 X H -X X X
J S 1 6 X H -X X X
J S 2 4 X H -X X X
J S 3 6 X H -X X X
A
40.5
45
65
82.4
B
23
26
37.5
48
C
23.7
30
45
57.1
D
26.6
31.6
33.7
40.2
E
14.5
18.8
21.1
21.1
Ød
10
16
24
36
Output Wave-1Output Wave-1 Output Wave-2Output Wave-2
Output Voltage CharacteristicOutput Voltage Characteristic Frequency CharacteristicFrequency Characteristic
A
B
D C
E
Ød
COM INPUT
–15V +15V OV
(COM)
Red
Green
White
Black
Dimension
Graph
Connection Diagram
00
30
10
20
50
40
05
25
55
35
4515
Prɪˈsɪʒən Laches is
Split CoreOn PrimaryFastening
26
How to use
• PC spring, secure locking hinge, one-touch structure make easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0
Features
Specification
• Power Metering.• Sub-metering for Building; Energy eciency monitoring, consumption analysis, and cost allocation.• Power Quality Monitoring for Distribution System Equipment.• Condition Monitoring for Conveyers, Pumps, etc.• Hybrid Inverter for Home Energy Storage.• Distributed Measurement Systems.
Applications
JPS10 / 20 / 33 / 52H Hall Sensor series, applying with accurate laminating core split technology and Open Loop technology PQ-CT OPENJPSXXH Series designed for strong durability and improves both existed error in low current and error occurred by ‘external vibrationand shock’ to minimize tolerance on cutting cross section of core. As compact one-touch split structure, it oers best solution for securityand fast installation on high frequency monitoring device instead of cutting power line. Rated current is DC5A-1200A, it satises with accuracy 1.0 and it certies with security accreditation IEC61010-1, UL61010-1 and EN61010-1 as ocial document.
JPS10 / 20 / 33 / 52H Hall Sensor series, applying with accurate laminating core split technology and Open Loop technology PQ-CT OPENJPSXXH Series designed for strong durability and improves both existed error in low current and error occurred by ‘external vibrationand shock’ to minimize tolerance on cutting cross section of core. As compact one-touch split structure, it oers best solution for securityand fast installation on high frequency monitoring device instead of cutting power line. Rated current is DC5A-1200A, it satises with accuracy 1.0 and it certies with security accreditation IEC61010-1, UL61010-1 and EN61010-1 as ocial document.
Open -Loop technology PQ-CT JPSXXH Series
MODEL
Rating currentSaturation current
Output voltage
Output linearityPower supply
di/dt response timeOutput temperature
character
Operating ConditionStorage Condition
Insulationwithstand voltage
±4 V, 1% at rated current RL=10KΩ
JPS10H- 005
5A7.5AT
JPS10H- 010
10A15AT
JPS10H- 015
15A22.5AT
JPS10H- 020
20A30AT
JPS10H- 025
25A37.5AT
JPS10H- 050
JPS10H- 075
JPS10H- 100
50A75AT
75A112.5AT
JPS20H- 050
JPS20H- 075
JPS20H- 100
JPS20H- 150 JPS20H
- 200JPS20H
- 250100A
JPS33H- 200
200A
JPS33H- 250
250A150AT 250AT
150A225AT 625AT
JPS33H- 300
300A625AT
JPS33H- 500
500A 600A 800A 1000A 1200A625AT 900AT 1200AT 1400AT 1400AT
JPS33H- 400
JPS52H- 300
JPS52H- 500
JPS52H- 600
JPS52H- 800
JPS52H- 1000
JPS52H- 1200JPS52H
- 400400A625AT
±20 mV max ( JPS20H, JPS33H, JPS52H )
3 μ sec (Typ.) at di/dt = F.S/μ Sec.
± 0.2% / °C (Typ.) ± 0.1% / °C (Typ.)
AC 4000V / 1min.
±1% rated current±15 V (±5%) 25mA
Insulation resistance DC 500V / 500MΩ max-25°C~+75°C, 85 % RH non-condensing-35°C~+90°C, 85 % RH non-condensing
Noise level
±30 mV max Less than (JPS10H)
< 20mVp-p (JPS10H)
< 10mVp-p ( JPS20H, JPS33H, JPS52H )
3 4
2
P2P1
1
Benefits• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.
JPS33H-300300A:±4VDC
JPS33H-300300A:±4VDC
Split CoreOn
PrimaryFastening
Unit : mm
Model
J P S 1 0 H - X X X
J P S 2 0 H - X X X
J P S 3 3 H - X X X
J P S 5 2 H - X X X
A
48
47.7
49
64
B
35
35
36
41
C
48
58
77.5
103.5
D
61
71.5
96
125
E
10
20
33
52
COM INPUT
–15V +15V OV
(COM)
10A/div
1V/div
10A/div
1V/div
12
8
4
0
-4
-8
-12-150 -100 -50 0 50 100 150
(V)
lo (A)
(lo=5A)(lo=5A)
[Hz]
(mV)
10 100 1000 104 105
0
200
400
600
800
1000
1200
1400
Output Wave-1Output Wave-1 Output Wave-2Output Wave-2
Output Voltage CharacteristicOutput Voltage Characteristic Frequency CharacteristicFrequency Characteristic
COM INPUT
–15V +15V OV
(COM)
Red
Green
White
Black
Graph
Connection Diagram
27
Open-Loop technology PQ-CT JPSXXH Series
Dimension
B
A D
EC
Specifi cation
4
1
2
3
Connector
Detail A1 2 43
ConnectorTerminal No.
Detail B
Features
Dimensions(unit : mm)
1
2
3
4
+V CC
V OUT
R L=10kΩ
GND
-V CC
Core=Silicon steel plate
1Terminal PinFunction + 15V
2– 15V
3Output
40 V
Panel mountingIndustrial temperature rangeUL94V0 complianceCE and RoHS available
Ø5
106
134.
6
208
4090
25.5
104.
5
12
3120 5
112
56188.5
Ø5.5
1 4
Connection
Open-Loop Current SensorsJHAO-XXXXSD(A/B) SeriesPanel
Mounting
Split Core
MODEL
Rating currentSaturation current
Output voltage
Output linearityPower supply
Di/dt response timeOutput temperature
character
Operating ConditionStorage Condition
Insulationwithstand voltage
±4 V, 0.5% at rated current RL=10KΩ
±20 mV
± 0.1% / °C (Typ.)
AC 4000V / 1min.
±0.5% rated current±15 V (±5%)
temperature character
Hysteresiserror
± 1mV / °C (Typ.)
25mV(IF=F.S) Less than 25mV
Insulation resistance DC 500V / 500MΩ max-10°C ~ +70°C-25°C ~ +85°C
JHAO-1000SD(X)
JHAO-1500SD(X)
JHAO-2000SD(X)
JHAO-2500SD(X)
JHAO-3000SD(X)
JHAO-4000SD(X)
JHAO-5000SD(X)
±1000 ±1500 ±2000 ±2500 ±3000 ±4000 ±5000
±2000 ±3000 ±4000 ±5000 ±6000 ±8000 ±8000
PCBMounting
Vcc=±12V @ ±10mA : 30Ω ~ 190Ω@ ±14mA : 30Ω ~ 100Ω
Vcc=±15V @ ±10mA : 100Ω ~ 350Ω@ ±14mA : 100Ω ~ 190Ω
29
Closed-Loop Voltage SensorJHVC-A25
Specification
Dimensions(unit : mm)
Features
+M
--
+
0V
+HT
- HT RN
-VN
+VN
IN R1
Primarycurrent
Excellent accuracy and linearityLow response time thermal driftHigh tolerance to external interferenceHigh bandwidth
ModelNominal inputMeasuring rangeMeasuring resistor(Vs = ±12...15V)
Output current(Im)Accuracy (Ta=+25°C)Turns ratioSupply voltages(Vs)Current consumption
Oset current (Ta=+25°C)
10mArms (10V...500V)JHVC-A25
0~±14mA
±25mAIN±1.0%2500:1000±12V~±15V (±5%)10mA+Im2.5kV RMS/ 50Hz/1min.Isolation voltage±0.2mA Max for primary current IN=0±0.2mA Typical; ±0.3mA Max (0°C~+70°C)Temperature drift< 0.1%Linearity< 10μsResponse time0~20kHzOperating Frequency range0°C~+70°COperating temperature-40°C~+85°CStorage temperature110Ω (Ta=+70°C)Secondary resistor250Ω (Ta=+70°C)Primary resistance22gWeight
27.4
15.24
29.8
21.2
3.445.44 20.32
2X7.62
5-Ø10
-
+
M
+HT
-HT
18
22
JHVC-A25-HT
+HT
+M
-
Connection
JHVC
-A25
JD12
0612
-HT
+HT
+M
-
PanelMounting
30
Electrical characteristics
General data
Voltage transducer uses special Isolation Barrier technology to measure AC and DC or Pulsed voltages. The primary input voltage and the output signal is highly electric isolated. It can be used in Power Utility, Converters, Traction, Telecom, Oil & Gas, and New energy elds.
Features
AC, DC, Pulsed voltage measurement Included primary resistor Good linearity Galvanic isolation between primary and secondary circuitLow power consumption High immunity to external interference Low thermal drift Higher voltage can measure than EVS30
Primary nominal voltage (Vrms)Primary voltage, measuring range (Vrms)Secondary Current output
Accuracy (Ta=+25°C)Linearity errorPower supply voltage (± 15V)Oset current (TA = +25 ˚C)
Frequency bandwidth
150% x VPN 50, 125, 150, 250, 500, 750, 1000, 1500, 2000, 2500, 3000 V
50 mA (EVS30-XXXX-A)
≤ 0.5%≤ 0.1%PN (± 5%)
6.0 kV
≤ ± 0.15 mAResponse time ≤ 10 μs
DC-1KHZ(-3dB) Current consumption 50mA (for current output: + IS )Load resistance ≤ 150Ω(for current output) or >5KΩ(for voltage output) Primary input resistance 60MΩIsolation test (50Hz,1min)
VPN
VP
RL
ISN
Secondary Voltage output 0 ± 5V (EVS30-XXXX-V)VSN
VC
IC
VD
XG
RP
εL
I0
f
TR
Ambient operating temperature Ambient storage temperature MassStandardsAmbient operating humidity Case material
-50 °C... +90 °C *-40 °C... +85 °C
350gEN5017820-90% RH According to UL94-V0
TA
TS
WST
HA
Digital Voltage SensorEVS30-XXXX-X Series
PanelMounting
31
Digital Voltage SensorEVS30-XXXX-X Series
Connection diagram
Dimensions (mm)
Output figure
M5 48 15
48.3 17
5.2
H+ H-
125.3
138
1515
3.3
Ø6.5
63
+ M -
E
+HV+Vc
0 V
-Vc
+
M
--HV
Is Rm
Isolationbarrier
+ VPN
- VPN
-50
50
Output in mA
0±50mA output
+ VPN
- VPN
-5
5
00
Output in V
0±5V output
± 1mm
Generaltolerance
BottomSide
: 2 x Ø 6.5(mm): 2 x Ø 4.8(mm)
Input Output
: 2 x M5: 2 x M5
Terminals Fastening
50 mA (EVS30-XXXX-A)0 ± 5V (EVS30-XXXX-V)
Voltage transducer uses special Isolation Barrier technology tomeasure AC and DC or Pulsed voltages and True RMS treatment, theoutput signal can be standard RMS voltage or current. The primaryinput voltage and the output signal is highly electric isolated. It canbe used in Power Utility, Converters, Traction, Telecom, Oil & Gas,and New energy elds.
Features
AC, DC, Pulsed voltage measurement Included primary resistor Good linearity Galvanic isolation between primary and secondary circuitLow power consumption High immunity to external interference Low thermal drift Higher voltage can measure than EVS30
Electrical characteristics
General data
PanelMounting
32
Digital Voltage SensorEVS30A-XXXX series
Primary nominal voltage (Vrms)
Primary voltage, measuring range (Vrms)
Secondary Current output
Secondary Voltage output
Accuracy (Ta=+25°C)
Linearity error
Power supply voltage (± 5%)
current (TA = +25 ˚C)
Response time
Frequency bandwidth
Current consumption
Load resistance
Isolation test (50Hz,1min)
VPN
VP
ISN
VSN
XG
εL
VC
I0
TR
f
IC
RL
VD
50, 150, 250, 500, 1000, 1500, 2000, 2500, 3000 V
150% x VPN
DC0-20mA, DC4-20mA
DC0-5V, DC0-10V
0.5%
≤ 0.1%
24Vdc
≤50mV / ≤±0.08mA
≤ 150mS
DC,20HZ-1KHZ(-3dB)
50mA (for current output:+ Is)
≤350Ω(for current output) or >5KΩ(for voltage output)
6.0 kV
Ambient operating temperature
Ambient storage temperature
Mass
Standards
Ambient operating humidity
Case material
TA
TS
W
ST
HA
-40 °C... +85 °C
-50 °C... +90 °C
350g
EN50178
20-90% RH
According to UL94-V0
Connection diagram
Dimensions (mm)
Output figure
PanelMounting
33
Digital Voltage SensorEVS30A-XXXX series
M5 48 15
48.3 17
5.2
H+ H-
125.3
138
1515
3.3
Ø6.5
63
+ M -
E
± 1mm
Generaltolerance
BottomSide
: 2 x Ø 6.5(mm): 2 x Ø 4.8(mm)
Input Output
: 2 x M5: 2 x M5
Terminals Fastening
+HV+Vc
0 V
-Vc
+
M
--HV
Is Rm
Isolationbarrier
DC0-5V output
DC4-20mA output
DC0-10Voutput
34
Checklist for Customers
Date
Company name
Location
Demander (name/dept./position)
Tel.
Fax.
QM Requirement
Project name
Application
Min. lot Q'ty
Annual estimated Q'ty
Target price
Q'ty of samplesrequired for
Contents
--
--
K pcs-
K pcs-
(USC/EUR/JPY)-
pcs-
--
-
Application
Nominal value
Power supply
di/dt to be followed
Preferred output
Turns ratio
Accuracy class
Overload requirement
Operating Temperature range
Operating Frequency
Dielectric withstand 2'nd-Earth
Dimensions
Primary Connection
Terminal Structure
Other requirements (if any, Diagram required for)
Current Monitoring Other( ) Energy Monitoring
+ ±
Max. ( )Min. ( )
( )rms
( )A/
Primary : Second ( : )
( )%
( )Hz
AC( )kV / 1min.
Inner Dia. - ( )mm, Width x Length x Height - ( x x )mm
( )% of Max. Primary Current
mA/A mV/A mA/A mV/A
Through hole Busbar Other
PCB Molex Cable
35
MEMO