Hall effect current sensor 모바일용 · AC variable speed drives and servo motor drives Static...

36
00 30 10 20 50 40 05 25 55 35 45 15

Transcript of Hall effect current sensor 모바일용 · AC variable speed drives and servo motor drives Static...

Page 1: Hall effect current sensor 모바일용 · AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power

00

30

10

20

50

40

05

25

55

35

4515

Page 2: Hall effect current sensor 모바일용 · AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power

J&D is a market leader in current and voltage sensors.

Built with its advanced AI and IoT technology, J&D is launching products such as the

Outdoor Waterproof Rogowski Coil CT, the Split-Core Power Metering CT,

an Advanced Power Quality Meter, a Branch Circuit Power Meter

and a Wireless Distribution Transformer Monitoring System.

The brand new PQ-CT Series, which consists of the JPS Series Split-Core

CT and the JRFS-RM Series Rogowski coil CT, can be used for power

quality monitoring and highly accurate revenue grade metering for

both AC and DC current.

J&D's new products are the best solution for smart grid applications

such as MV / LV substations, power quality meters, energy meters,

branch circuit meters, PV monitoring, motor quality diagnostics,

Traction and data center,etc

Page 3: Hall effect current sensor 모바일용 · AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power

CONTENTSFor Smart Industry

Measuring Principles

Applications

Closed-Loop Current Sensor

* JP-50/100

* JP-200

* JPC-200X

* JPC-300X

* JPC-500X

* JPC-1000X

* JPC-2000X

Open-Loop Current Sensor / Technology PQ-CT

* JHAO-XXXG(A/B) Series

* JHAO-XXXC(A/B) Series

* JHAO-XXXXD Series

* JM21XH-XXX-XXX Series

* JSXXXH-XXX Series

* JPSXXH Series

* JHAO-XXXXSD(A/B) Series

Closed-Loop Voltage Sensor

* JHVC-A25

Digital Voltage Sensor

* EVS30-XXXX-X Series

* EVS30A-XXXX Series

Checklist for Customers

04

05

06

08

09

10

12

14

16

18

20

21

22

23

24

26

28

29

30

32

34

Page 4: Hall effect current sensor 모바일용 · AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power

The importance of Smart Industrial applications is increasing in order to save energy and cost.Smart Industrial applications are controlled by power loss and accurate regulation of electronic parameters such as current, voltage and power.J&D uses innovative technologies to ensure the high degree of reliability and safety that our customers require.J&D offers a comprehensive range of accurate, reliable and galvanically isolated devices to measure AC/DC current from 3A to 6000A and AC/DC voltage from 10V to 3000V by acrossing wide range of technologies.J&D CT are UL/CE marked in recognition of their electromagnetic compatibility and compliance to Safety standards.

Typical applications include

Power supplies for welding, medical, Elevators

Servo motor drives & Inverters

Uninterruptible power supplies (UPS)

PV monitoring

Pumps & fans control/monitoring

Traction & Trackside

Converters, Rectifiers

Solar / Photovoltaics

for Smart Industry

4

New Precision Hall effect Technology

Page 5: Hall effect current sensor 모바일용 · AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power

5

Measuring Principles

IN VM

RL+VA

0VM

- VA

IN

+VA

0V

- VA

+ HT

- HT

+VA

- VA

0V

+

M

-

RMIS

VM

Measuring Principle of Isolation Amplifier TechnologyOur Isolation Amplier Technology Voltage Sensors - iSAST EVS series begins with an internal resistor network. This network measures DC Voltage by directly contacting both the Positive High Voltage (+HT) and the Negative High Voltage (-HT).This Voltage signal is transmitted to the secondary side of the sensor through an insulat-ed transformer that isolates the Primary High Voltage from the Secondary Low Voltage. The resulting signal is then converted through an amplier into either a current or a Voltage signal. Therefore the circuit converts a primary Voltage into a secondary current or Voltage that is proportional to the input.

J&D AC/DC CTs provide non-contact detection of AC/DC current.The AC/DC CTs have two types of split-core & solid-core design with various utility, high reliability & Cost-effective solution for precise current measurements.The rated current range is 5A to 6000A AC/DC and secondary output value is 4/5/10 V/333mV DC & 4-20 mA, Instantaneous AC/DC current.

Measuring Principle of Open-Loop Current TechnologyOpen-loop Hall eect technology creates magnetic ux from the input primary current and its magnetic ux couples a proportional low voltage, which amplify before being output.

Measuring Principle of Closed-Loop Current TechnologyThe secondary current is generated by transferring the proportional voltage of the hall sensor originated by the magnetic ux from the primary current.The feedback of the compensating current via the secondary winding closes the loop, where by this current is an exact representation of the primary current.

J&D AC/DC VT offers a comprehensive range of accurate, reliable and galvanically isolated devices to measure AC/DC voltage from 10V to 3000V across a range of technologies.

Measuring Principle of Closed-Loop Voltage TechnologyWhen a primary Voltage is applied to the input resistor Ri, the current Ip ows through the wire of the input W1 coil and generates a magnetic ux passing the Hall Sensor. The closed-loop feedback amplier used the Hall Voltage to generate a compensating current which is applied to the secondary winding W2 thereby creating the compensat-ing magnetizing ux. This current is exactly proportional to primary current Ip through Ri and the input Voltage Vm and as it ows through the output metering resistor RL it creates a voltage drop Vm which is proportional to the Primary Voltage Vm. Dependent on the ratio Ri/Rl you can get a wished voltage transfer ratio.

VM

RL+VA

0VM

- VA

NP W1

W2’1

W2’2

IP

VM

Ri

Page 6: Hall effect current sensor 모바일용 · AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power

6

Applications

Battery SuppliedApplications

Static Convertersfor DC Motor Drives

1~3~

~-

M~IpConverter

1~ ~-

Field Rectier

I

1~3~

~-

IpCharger

3~~- M~

IMBattery Inverter

G~3~3~ ~

- ~-

IG ILVDC

IDCRectier or

InverterDC-Link PWM

Inverter

1~3~ 3~

~- ~

- M~IL IMVDC

IDCRectier or

InverterDC-Link PWM

InverterAC Variable Speed Drives

and Servo Motor Drives

1~3~

~-

Battery~-

IVDC

IDCCharger DC-Link Inverter

UninterruptiblePower Supplies (UPS)

1~3~

~-

-

I

PWMInverter

-IVDC

IDCInput

RectierDC-Link Output

Rectier

AC

DCPower Supplies forWelding Applications

1~3~

~-

-

PWMInverter

-IVDC

IDCInput

RectierDC-Link Output

Rectier

Switched ModePower Supplies (SMPS)

Page 7: Hall effect current sensor 모바일용 · AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power

7

Page 8: Hall effect current sensor 모바일용 · AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power

PCBMounting

8

Closed-Loop Current SensorJP-50/100

14.5

7.3

6.85

54.5

37

15.223

27.8

15.6

0.5

7.3

5.2

Unless otherwise specied,tolerances shall be ±0.5mm

Closed loop (compensated) current transducer using the Hall eectPrinted circuit board mounting Insulated plastic case recognized according to UL 94-V0.

IPIS Rm

0V

+Vc

–Vc

M

+

Features

Electrical Properties

Dimension Connection

Unit : mm [inch]

Primary nominal currentMeasuring resistance

Rated output current

Output current accuracyOset currentOutput linearity

Vcc=±12V @ ±50A : 60Ω ~ 95Ω@ ±60A : 60Ω

Vcc=±15V @ ±50A : 135Ω ~ 155Ω @ ±55A : 135Ω

50A

50mA( Turn ratio 1:1000)

≤ ±0.1mA (at If=0A)

Model JP-50

≤ ±0.15%(at If )±12V ±5% ~ ±15V ±5% (output current is restricted by Vcc)Power supply voltage

≤ 1μS(at di/dt=If/μs)Response time

≤ ± 0.01%/˚C(Without TcIof )Thermal drift of gain≤ ± 0.5mAThermal drift of oset

≤ 0.3mA (at If=0A → If → If=0A)Hysteresis error

IfRL

TCIO

IO

tr

IoH

AC3000V for 1 minute (Sensing current 0.5mA)inside of through hole ⇔ terminal

Insulation voltage VD

V

TCIOf

≥500MΩ (at DC500V) inside of through hole ⇔ terminalInsulation resistance-40˚C ~ +85˚CAmbient Operating temperature-40˚C ~ +90˚CAmbient storage temperature

80Ω(@Ta=70˚C)85Ω(@Ta=85˚C)

Vcc=±12V @ ±100A : 0Ω ~ 42Ω @ ±120A : 0Ω ~ 14Ω

Vcc=±15V @ ±100A : 20Ω ~ 102Ω @ ±150A : 20Ω ~ 25Ω

100A

50mA( Turn ratio 1:2000)

≤ ±0.2mA (at If=0A)±0.45 (±15V, +25˚C ) ±0.65 (±15V, +25˚C )

JP-100

120Ω(@Ta=70˚C)128Ω(@Ta=85˚C)

Secondary coil resistance

TA

RIS

RS

TS

Iof

εL

VCC

DC…200kHz (-1 dB)Frequency characteristics f

Page 9: Hall effect current sensor 모바일용 · AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power

PCBMounting

Unit : mm [inch]

Closed-Loop Current SensorJP-200

Closed loop (compensated) current transducer using the Hall eectPrinted circuit board mounting Insulated plastic case recognized according to UL 94-V0.

Electrical Properties

Dimension Connection

9

Features

48.613 18

0.6

11.612.7

12.75.1

13.95.1

33.6

0.511

4

5.5

40.64

6.95 8.89

Ø1.75

15.84

IP IS Rm0V

+Vc

–Vc

NC

M

+

Unless otherwise specied,tolerances shall be ±0.5mm

Primary nominal currentMeasuring resistance

Rated output current

Output current accuracyOset currentOutput linearity

Vcc=±12V @ ±200A : 0Ω ~ 26ΩVcc=±12V @ ±250A : 0Ω ~ 4ΩVcc=±15V @ ±200A : 0Ω ~ 56ΩVcc=±15V @ ±300A : 0Ω ~ 8Ω

200A

100mA ( Turn ratio 1:2000)

≤ ±0.2mA (at If=0A)

Model JP-200

≤ ±0.15%(at If )±12V ±5% ~ ±15V ±5% (Rated output current is restricted by Vcc)Power supply voltage

≤ 1μS(at di/dt=If/μs)Response time

≤ ± 0.01%/˚C(Without TcIof )Thermal drift of gain≤ ± 0.5mAThermal drift of oset

≤ 0.3mA (at If=0A → If → If=0A)Hysteresis error

IfRL

TCIO

IO

tr

IoH

AC3000V for 1 minute (Sensing current 0.5mA)inside of through hole ⇔ terminal

Insulation voltage VD

V

TCIOf

≥500MΩ (at DC500V) inside of through hole ⇔ terminalInsulation resistance-40˚C ~ +85˚CAmbient Operating temperature-40˚C ~ +90˚CAmbient storage temperature

76Ω(@Ta=70˚C)80Ω(@Ta=85˚C)

±0.4 (±15V, +25˚C )

Secondary coil resistance

TA

RIS

RS

TS

Iof

εL

VCC

DC…100kHz (-1 dB)Frequency characteristics f

Page 10: Hall effect current sensor 모바일용 · AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power

PanelMounting

VD

10

Closed-Loop Current SensorJPC-200X

Applications

Specification

Features

AdvantagesFor the electronic measurement of currents : AC/DC current sensor, JPC series has good stability in high currents anda highly insulated primary and secondary.

AC variable speed drives and servo motor drivesStatic converters for DC motor drivesBattery supplied applicationsUninterruptible Power Supplies (UPS)Switched Mode Power Supplies (SMPS)Power supplies for welding applications.

Closed loop (compensated) current transducer using the Hall eectInsulated plastic case recognized according to UL 94-V0Panel mounting

Excellent accuracyVery good linearity

Low temperature driftOptimized response timeWide frequency bandwidthNo insertion lossesHigh immunity to external interferenceCurrent overload capability.

MODEL

ConnectorPrimary nominal current rms

Secondary nominal current rms

Current consumption @ ± 15 V Supply voltage (+/-5%) Conversion ratio

Overall accuracyLinearity error

Insulation voltage

Reaction time to 10 % of IPN stepReaction time to 90 % of IPN stepdi/dt accurately followedFrequency bandwidth (- 3 dB) Ambient Operating temperatureAmbient storage temperatureSecondary coil resistance

Primary current, measuring rangeMeasuring resistance

0 .. ± 420

1001 : 2000

± 12 .. 15

± 0.517 + IS

< 0.1Max. ± 0.2

AC 3500V / 1min.

< 500< 1 (With a di/dt of 100 A/µs.)

> 100DC .. 100

- 40 .. + 85- 40 .. + 90

33 (@Ta=70˚C) / 35 (@Ta=85˚C)

± 12V Ta=70˚C : 0 ~ 71 Ta=70˚C : 0 ~ 14

Ta=85˚C : 0 ~ 69Ta=85˚C : 0 ~ 12

± 15V Ta=70˚C : 0 ~ 100Ta=70˚C : 0 ~ 28

@ ± 200A@ ± 420A@ ± 200A@ ± 420A

Ta=85˚C : 23 ~ 98Ta=85˚C : 23 ~ 26

JPC-200F

39-28-8040[5566-04A-210] Molex200

-A

V

%%

mAMax. ± 0.1(@ IP M, after an overload of 3 x IPN)mA

Temperature variation Typ. ± 0.12 , Max. ± 0.4 (-45˚C...+85˚C)mAns

mA-

kHz˚C˚CΩ

Mass 78g

Standards EN 50178: 1997 / IEC 61010-1-

mA

JPC-200T

38-00-6293[6410-03C(102)] MolexSPEC

Page 11: Hall effect current sensor 모바일용 · AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power

PanelMounting

53.8

4.3

61

12

19.5

1.2

12

24

24.5

4

4

53.8

4.3

6112

19.5

1.2

12

24

24.5

4

4

11

Closed-Loop Current SensorJPC-200X

Dimensions(mm)

3

2

4

1

Connector

Detail AConnector

Molex

Manufacturer

39-28-8040

Part Number

5566-04A-210

Old Part Number

Primary through-hole Ø 15.5 mm

IP

IS Rm0V

+Vc

–Vc

NC

2134

M

+

3

2

1

Connector

Terminal No.

Detail B

Connector

Molex

Manufacturer

38-00-6293

Part Number

6410-03C (102)

Old Part Number

Primary through-hole Ø 15.5 mm

IP

IS Rm0V

+Vc

–Vc

213

M

+

JPC-200T

JPC-200F

2.5 26.5

51

41.3

49

R7.8

15.1

7.3

41.3

4.3

39.5

A

A

A

49

2.5 26.5

51

41.3

R7.8

15.1

7.3

41.3

4.3

39.5

B

A

A

Page 12: Hall effect current sensor 모바일용 · AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power

PanelMounting

12

Closed-Loop Current SensorJPC-300X

Applications

Specification

Features

Advantages

For the electronic measurement of currents : AC/DC current sensor, JPC series has good stability in high currents anda highly insulated primary and secondary.

AC variable speed drives and servo motor drivesStatic converters for DC motor drivesBattery supplied applicationsUninterruptible Power Supplies (UPS)Switched Mode Power Supplies (SMPS)Power supplies for welding applications.

Closed loop (compensated) current transducer using

Insulated plastic case recognized according to UL 94-V0Panel mounting

Excellent accuracyVery good linearity

Low temperature driftOptimized response timeWide frequency bandwidthNo insertion lossesHigh immunity to external interferenceCurrent overload capability.

MODEL

ConnectorPrimary nominal current rms

Secondary nominal current rms

Current consumption @ ± 15 V Supply voltage (+ 5 %) Conversion ratio

Overall accuracyLinearity error

Temperature variationReaction time to 10 % of IPN stepReaction time to 90 % of IPN stepdi/dt accurately followedFrequency bandwidth (- 1 dB) Ambient Operating temperatureAmbient storage temperatureSecondary coil resistance

Primary current, measuring rangeMeasuring resistance @

0 .. ± 500

1001 : 3000

± 12 .. 20

± 0.526(@ ±20V) + IS

< 0.1Max. ± 0.2

Typ. ± 0.2, Max. ± 0.7 (- 40˚C .. + 85˚C) / Typ. ± 0.1 , Max. ± 0.3 (- 10˚C .. + 70˚C)

< 500< 1 (With a di/dt of 100 A/µs.)

> 100DC .. 100

- 40 .. + 85- 40 .. + 85

30 (@Ta=70˚C) / 32 (@Ta=85˚C)

± 12V Ta=70˚C : 0 ~ 37 Ta=70˚C : 0 ~ 10

Ta=85˚C : 0 ~ 35Ta=85˚C : 0 ~ 8

± 15V Ta=70˚C : 0 ~ 56Ta=70˚C : 0 ~ 21

@ ± 300A@ ± 500A@ ± 300A@ ± 500A

Ta=85˚C : 0 ~ 54Ta=85˚C : 0 ~ 19

± 20V Ta=70˚C : 0 ~ 88Ta=70˚C : 0 ~ 40

@ ± 300A@ ± 500A

Ta=85˚C : 0 ~ 86Ta=85˚C : 0 ~ 38

JPC-300F

39-28-8040[5566-04A-210] Molex300

-A

V

%%

mAMax. ± 0.2 (@ IP M, after an overload of 3 x IPN)mA

mAns

mA-

kHz˚C˚CΩ

Mass 95g

Standards EN 50178: 1997 / IEC 61010-1-

mA

JPC-300T

38-00-6293[6410-03C(102)] MolexSPEC

VDInsulation voltage AC 3800V / 1min.

Page 13: Hall effect current sensor 모바일용 · AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power

PanelMounting

13

Closed-Loop Current SensorJPC-300X

Dimensions(mm)

Connector

Detail B

1

2

3

Connector

Molex

Manufacturer

38-00-6293

Part Number

6410-03C (102)

Old Part Number

Primary through-hole Ø 20.1 mm

IP

IS Rm0V

+Vc

–Vc

213

M

+

JPC-300T

JPC-300F

Current Direction

A

Connector

Detail A

3

2

4

1

Connector

Molex

Manufacturer

39-28-8040

Part Number

5566-04A-210

Old Part Number

Primary through-hole Ø 20.1 mm

IP

IS Rm0V

+Vc

–Vc

NC

2134

M

+

46

46

4.3

54

20.2

R10

56.5

29.5

10

3

44

A

A

60

68

1313

26.3

18.5

1.2

10

26.3

5

26

46

46

4.3

54

20.2

R10

56.5

29.5

10

3

44

A

A

60

68

1313

26.3

18.5

1.2

10

26.3

5

26

B

Page 14: Hall effect current sensor 모바일용 · AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power

PanelMounting

14

Specification

Closed-Loop Current SensorJPC-500X

Applications Features

Advantages

AC variable speed drives and servo motor drivesStatic converters for DC motor drivesBattery supplied applicationsUninterruptible Power Supplies (UPS)Switched Mode Power Supplies (SMPS)Power supplies for welding applications.

For the electronic measurement of currents : AC/DC current sensor, JPC series has good stability in high currents anda highly insulated primary and secondary.

Closed loop (compensated) current transducer using the Hall eectInsulated plastic case recognized according to UL 94-V0Panel mounting

Excellent accuracyVery good linearityLow temperature driftOptimized response timeWide frequency bandwidthNo insertion lossesHigh immunity to external interferenceCurrent overload capability.

MODEL

ConnectorPrimary nominal current rms

Secondary nominal current rms

Current consumption @ ± 15 V Supply voltage (+ 5 %) Conversion ratio

Overall accuracyLinearity errorOset current

Temperature variationReaction time to 90 % of IPN stepdi/dt accurately followedFrequency bandwidth (- 1 dB) Ambient Operating temperatureAmbient storage temperatureSecondary coil resistance

Primary current, measuring rangeMeasuring resistance @

0 .. ± 800

1001 : 5000

± 15 .. 24

± 0.624(@ ±18V) + IS

< 0.1Max. ± 0.4

Typ. ± 0.1, Max. ± 0.4 (- 40˚C .. + 70˚C)< 1 (With a di/dt of 100 A/µs.)

> 100DC .. 100

- 40 .. + 70- 40 .. + 85

70 (@Ta=70˚C)

± 15V 0 ~ 60 0 ~ 11± 18V 0 ~ 92 0 ~ 30

@ ± 500A @ ± 800A@ ± 500A @ ± 800A

± 24V 5 ~ 149 5 ~ 65@ ± 500A @ ± 800A

JPC-500F

39-28-8040[5566-04A-210] Molex500

-A

V

%%

mA

Magnetic oset current Max. ± 0.2 (@ IP = 0 and specied RM, after an overload of 3 x IPN)mA

A/μs

mA

mA

μs

-

kHz˚C˚CΩ

Mass 230g

Standards EN 50178: 1997 / IEC 61010-1-

mA

JPC-500T

38-00-6293[6410-03C(102)] MolexSPEC

VDInsulation voltage AC 3800V / 1min.

Page 15: Hall effect current sensor 모바일용 · AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power

PanelMounting

15

Dimensions(mm)

Closed-Loop Current SensorJPC-500X

Primary through-hole Ø 30.2 mm

Connector

Molex

Manufacturer

39-28-8040

Part Number

5566-04A-210

Old Part Number

4

1

2

3

Connector

Detail A

IP

IS Rm0V

+Vc

–Vc

NC

3421

M

+

Primary through-hole Ø 30.2 mm

Connector

Molex

Manufacturer

38-00-6293

Part Number

6410-03C (102)

Old Part Number

3

2

1

Connector

Terminal No.

Detail B

IP

IS Rm0V

+Vc

–Vc

213

M

+

JPC-500T

JPC-500F

R15.1

1030.2

4.3

5658

70

A

A

16

77

80

89

6-4.3

15.5

31

31.5

18.5

5

31.5

1.5

2931

A

R15.1

1030.2

4.3

5658

70

A

A

16

77

80

89

6-4.3

15.5

31

31.5

18.5

5

31.5

1.5

2931

B

Page 16: Hall effect current sensor 모바일용 · AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power

PanelMounting

16

Specification

Closed-Loop Current SensorJPC-1000X

Applications Features

AdvantagesFor the electronic measurement of currents : AC/DC current sensor, JPC series has good stability in high currents anda highly insulated primary and secondary.

AC variable speed drives and servo motor drivesStatic converters for DC motor drivesBattery supplied applicationsUninterruptible Power Supplies (UPS)Switched Mode Power Supplies (SMPS)Power supplies for welding applications.

Closed Loop (compensated) current transducer using the Hall eectInsulated plastic case recognized according to UL 94-V0Panel mounting

Excellent accuracyVery good linearityLow temperature driftOptimized response timeWide frequency bandwidthNo insertion lossesHigh immunity to external interferenceCurrent overload capability.

MODEL

ConnectorPrimary nominal current rms

Secondary nominal current rms

Current consumption ( ± 1mV )Supply voltage (+ 5 %) Conversion ratio

Overall accuracyLinearity errorOset current

Temperature variationReaction time to 90 % of IPN stepdi/dt accurately followedFrequency bandwidth (- 1 dB) Ambient Operating temperatureAmbient storage temperatureSecondary coil resistance

Primary current, measuring rangeMeasuring resistance

0 .. ± 1500

2001 : 5000

± 15 .. 24

± 0.428(@ ±24V) + IS

< 0.1Max. ± 0.4

Typ. ± 0.3, Max. ± 0.5 (- 10˚C .. + 85˚C) / Max. ± 0.8 (- 40˚C .. - 10˚C)< 1 (With a di/dt of 100 A/µs.)

> 100DC .. 150

- 40 .. + 85- 45 .. + 100

48 (@Ta=70˚C) / 51 (@Ta=85˚C)

± 15V Ta=70˚C : 0 ~ 18 Ta=70˚C : 0 ~ 7

Ta=85˚C : 0 ~ 15Ta=85˚C : 0 ~ 4

± 24V Ta=70˚C : 5 ~ 60.5Ta=70˚C : 5 ~ 24

@ ± 1000A@ ± 1200A@ ± 1000A@ ± 1500A

Ta=85˚C : 10 ~ 57.5Ta=85˚C : 10 ~ 21

JPC-1000F

39-28-8040[5566-04a-210] Molex1000

-A

V

%%

mA

Magnetic oset current Max. ± 0.2(@ IP = 0 and specied RM, after an overload of 3 x IPN)mAInsulation voltage AC 3800V / 1min.VD

A/μs

mA

mA

μs

-

kHz˚C˚CΩ

Mass 550g

Standards EN 50178: 1997 / IEC 61010-1-

mA

JPC-1000T

38-00-6293[6410-03c(102)] MolexSPEC

Page 17: Hall effect current sensor 모바일용 · AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power

PanelMounting

17

Closed-Loop Current SensorJPC-1000X

Dimensions(mm)

Primary through-hole 40.5 x 13 mm or Ø 38 mm

Connector

Molex

Manufacturer

38-00-6293

Part Number

6410-03C (102)

Old Part Number

B

3

2

1

Connector

Terminal No.

Detail B

IP

IS Rm0V

+Vc

–Vc

213

M

+

JPC-1000T

JPC-1000F

A

4

1

2

3

Connector

Detail A

Primary through-hole 40.5 x 13 mm or Ø 38 mm

Connector

Molex

Manufacturer

39-28-8040

Part Number

5566-04A-210

Old Part Number

IP

IS Rm0V

+Vc

–Vc

NC

3421

M

+

5.3

7994

13.5

40.5

R19.25

79

3.548

77

A

A

34.5

100

110

19

17

4-4.3

2- 5.3

34

19.5

95

1.5

3434.5

431.5

5.3

7994

13.5

40.5

R19.25

79

3.548

77

A

A

34.5

100

110

19

17

4-4.3

2- 5.3

34

19.5

95

1.5

3434.5

431.5

Page 18: Hall effect current sensor 모바일용 · AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power

PanelMounting

18

Closed-Loop Current SensorJPC-2000X

For the electronic measurement of currents : AC/DC current sensor, JPC series has good stability in high currents anda highly insulated primary and secondary.

AC variable speed drives and servo motor drivesStatic converters for DC motor drivesBattery supplied applicationsUninterruptible Power Supplies (UPS)Switched Mode Power Supplies (SMPS)Power supplies for welding applications.

Closed loop (compensated) current transducer using the Hall eectInsulated plastic case recognized according to UL 94-V0 Panel mounting

Excellent accuracyVery good linearityLow temperature driftOptimized response timeWide frequency bandwidthNo insertion lossesHigh immunity to external interferenceCurrent overload capability.

MODEL

ConnectorPrimary nominal current rms

Secondary nominal current rms

Current consumption ( ± 1mV )Supply voltage (+ 5 %) Conversion ratio

Overall accuracyLinearity errorOset current

Temperature variationReaction time to 90 % of IPN stepdi/dt accurately followedFrequency bandwidth (- 1 dB) Ambient Operating temperatureAmbient storage temperatureSecondary coil resistance

Primary current, measuring rangeMeasuring resistance

0 .. ± 3000

4001 : 5000

± 15 .. 24

± 0.333(@ ±24V) + IS

< 0.1Max. ± 0.5

Typ. ± 0.2, Max. ± 0.5 (- 25˚C .. + 85˚C) / Max. ± 1.5 (- 40˚C .. - 25˚C)< 1 (With a di/dt of 100 A/µs.)

> 50DC .. 100

- 40 .. + 85- 50 .. + 90

25 (@Ta=70˚C) / 26 (@Ta=85˚C)

± 15V Ta=70˚C : 0 ~ 8 Ta=70˚C : 0 ~ 5

Ta=85˚C : 0 ~ 7Ta=85˚C : 0 ~ 4

± 24VTa=70˚C : --------Ta=70˚C : 5 ~ 11

@ ± 2000A@ ± 2200A

@ ± 2800A@ ± 3000A

Ta=85˚C : 13 ~ 13Ta=70˚C : 5 ~ 29@ ± 2000A Ta=85˚C : 13 ~ 28

Ta=85˚C : ---------

JPC-2000F

39-28-8040[5566-04a-210] Molex2000

-A

V

%%

mA

Magnetic oset current Max. ± 0.2(@ IP = 0 and specied RM, after an overload of 3 x IPN)mA

Insulation voltage AC 6000V / 1min.VD

A/μs

mA

mA

μs

-

kHz˚C˚CΩ

Mass 1.5kg

Standards EN 50178: 1997 / IEC 61010-1-

mA

JPC-2000T

38-00-6293[6410-03c(102)] MolexSPEC

Applications Features

Advantages

Specification

Page 19: Hall effect current sensor 모바일용 · AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power

PanelMounting

19

Closed-Loop Current SensorJPC-2000X

Dimensions(mm)

Primary through-hole 60.5 x 20.5 mm or Ø max 57 mm

Connector

Molex

Manufacturer

38-00-6293

Part Number

6410-03C (102)

Old Part Number Detail A3

2

1

Connector

Terminal No.

Detail B

IP

IS Rm0V

+Vc

–Vc

213

M

+

JPC-2000T

JPC-2000F

Primary through-hole 60.5 x 20.5 mm or Ø max 57 mm

Connector

Molex

Manufacturer

39-28-8040

Part Number

5566-04A-210

Old Part Number

4

1

2

3

Connector

Detail A

IP

IS Rm0V

+Vc

–Vc

NC

3421

M

+

6.5

103.5

135

20.5

60.5

103.5

R28.75

4 67.5

A

A

A

185252.5

2.5

134

5

152

6.5

30

170

11

52 52.5

18.5

6.5

103.5

135

20.5

60.5

103.5

R28.75

4 67.5

A

A

185252.5

2.5

134

5

152

6.5

30

170

11

52 52.5

18.5

B

Page 20: Hall effect current sensor 모바일용 · AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power

PanelMounting

20

Open-Loop Current SensorsJHAO-XXXG(A/B) Series

* Sux(X)=A/B

1

2

3

4

+VCC

VOUT

RL=10kΩ

GND

-VCC

Core=Silicon steel plate

1Terminal PinFunction + 15V

2– 15V

3Output

40 V

Panel mountingIndustrial temperature rangeUL94-V0 complianceCE and RoHS available

MODEL

Rating currentSaturation current

Output voltage

Output linearityPower supply

Di/dt response timeOutput temperature

character

Operating ConditionStorage Condition

Oset voltage

Insulationwithstand voltage

±4 V, 1% at rated current RL=10KΩ

JHAO-050G(X)

50A150AT

JHAO-075G(X)

75A225AT

JHAO-100G(X)

100A300AT

JHAO-150G(X)

150A450AT

JHAO-200G(X)

200A600AT

JHAO-300G(X)

300A

JHAO-400G(X)

400A

JHAO-500G(X)

500A

JHAO-600G(X)

600A900AT

±30 mV max Less than ±50 mV max±15 mV max

3 μ sec (Typ.) at di/dt = F.S/μ Sec.

± 0.1% / °C (Typ.)

AC 2500V / 1min.

±1% rated current±15 V (±5%) 20mA

Oset voltagetemperature character

± 2mV/°C

Hysteresiserror

30mV Less than 30mV

± 1mV / °C (Typ.)

25mV(IF=F.S) Less than 25mV

Insulation resistance DC 500V / 500MΩ max

Frequency bandwidth 20kHz-15°C~+80°C-15°C~+85°C

Specification

Dimension Connection

Unit : mm [inch]

40

30

10.3

20.3

204.75Ø2.5

Ø4.6

32.5

20

3025

4.7

MOLEX5045-04AG

orGEOYOUNG

LPH01-041234

→If

JHAO-XXXGB40

30

10.3

20.3

204.75Ø2.5

Ø4.6

32.5

20

3025

4.7

MOLEX5045-04AG

orGEOYOUNG

LPH01-04

1234

→If

JHAO-XXXGA

Features

Page 21: Hall effect current sensor 모바일용 · AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power

PanelMounting

21

Open-Loop Current SensorsJHAO-XXXC(A/B) Series

JHAO-XXXCB48

Ø30

78

54

10

61 20.5

MOLEX5045-04AG

orGEOYOUNG

LPH01-04

2-Ø4.5

20.5 9.

8

53.5

17

7.8

1 2 3 4

→If

JHAO-XXXCA

→40

2-Ø4.5

20.5

45.5

17

Ø22

70

50

If

53

MOLEX5045-04AG

orGEOYOUNG

LPH01-04

10

1 2 3 4

9.8

7.8

1

2

3

4

+VCC

VOUT

RL=10kΩ

GND

-VCC

Core=Silicon steel plate

1Terminal PinFunction + 15V

2– 15V

3Output

40 V

Panel mountingIndustrial temperature rangeDesigned for round-wire, output connector typeUL94-V0 complianceCE and RoHS availableTwo dierent size (A : 22Ø / B : 30Ø)

MODEL

Rating currentSaturation current

Output voltage

Output linearityPower supply

Di/dt response timeOutput temperature

character

Operating ConditionStorage Condition

Oset voltage

Insulationwithstand voltage

±4 V, 1% at rated current RL=10KΩ

JHAO-050C(X)

50A150AT

JHAO-075C(X)

75A225AT

JHAO-100C(X)

100A300AT

JHAO-150C(X)

150A450AT

JHAO-200C(X)

200A600AT

JHAO-300C(X)

300A

JHAO-400C(X)

400A

JHAO-500C(X)

500A

JHAO-600C(X)

600A900AT

±30 mV max Less than ±50 mV max±15 mV max

3 μ sec (Typ.) at di/dt = F.S/μ Sec.

± 0.1% / °C (Typ.)

AC 2500V / 1min.

±1% rated current±15 V (±5%) 20mA

Oset voltagetemperature character

± 2mV/°C

Hysteresiserror

30mV Less than 30mV

± 1mV / °C (Typ.)

25mV(IF=F.S) Less than 25mV

Insulation resistance DC 500V / 500MΩ max-15°C~+80°C-15°C~+85°C

Specification

Dimension Connection

Unit : mm [inch]

* Sux(X)=A/B

Features

Page 22: Hall effect current sensor 모바일용 · AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power

PanelMounting

22

Connection

Open-Loop Current SensorsJHAO-XXXXD Series

Features

Specification

Dimensions(unit : mm)

1

2

3

4

+V CC

V OUT

R L=10kΩ

GND

-V CC

Core=Silicon steel plate

1Terminal PinFunction + 15V

2– 15V

3Output

40 V

Panel mountingIndustrial temperature rangeUL94V0 complianceCE and RoHS available

MODEL

Rating currentSaturation current

Output voltage

Output linearityPower supply

Di/dt response timeOutput temperature

character

Operating ConditionStorage Condition

Oset voltage

Insulationwithstand voltage

±4 V, 1% at rated current RL=10KΩ

JHAO-200D(X)±200A±600A

JHAO-400D(X)±400A

±1200A

JHAO-500D(X)±500A

±1500A

JHAO-600D(X)±600A

±1800A

JHAO-750D(X)±750A

±2250A

JHAO-800D(X)±800A

JHAO-1000D(X)±1000A

JHAO-1200D(X)±1200A

JHAO-1500D(X)±1500A

±2400A ±3000A

±30 mV

7 μ sec (Typ.) at di/dt = F.S/μ Sec.

± 0.1% / °C (Typ.)

AC 2500V / 1min.

±1% rated current±15 V (±5%)

Oset voltagetemperature character

Hysteresiserror

± 1mV / °C (Typ.)

25mV(IF=F.S) Less than 25mV

Insulation resistance DC 500V / 500MΩ max-40°C ~ +105°C-40°C ~ +125°C

* Sux(X)=A/B

63

53 6530.5

42.5

19.5 8.25

70.5

89

78.542

142412

5

5

3843

1

4

OFS

R2.3

Ø4.6

Ø4.6

24

43

6 612

Page 23: Hall effect current sensor 모바일용 · AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power

23

Open-Loop Current SensorsJM21XH-XXX-XXX Series

28.4

9

95

80.5

4.7 7.2

19.7

2.5

• Dimensions (unit : mm)

Mount the bracket on the rail and install current transformer

DIN RAIL MOUNTING51

.5

46

7035

35

24.27

• Dimensions (unit : mm)

Tighten screws on the hole to mount bracket and install current transformer

PANEL MOUNTING

- +

70 60

64228

O G

2840.3

23.8

14.5 2000 ± 50AWG #18

8

Relay cable(common)(attached with CT)

Power supply: 24VDC

O : OutputG : GND

Part-NO. : 56002(red)

Specification Acc essory O ption

Dimensions (unit : mm)

Split-core current transducer for the electronic measurement of DC or AC wave-form currents, with galvanic isolation between the primary circuit and the Split-core current transducer for the electronic measurement of DC or AC wave-form currents, with galvanic isolation between the primary circuit and the secondary circuit (measurement). True-RMS outputs proportional to theprimary current: Either 0-5V DC or Active Current Source 4-20mA DC.

ㆍAutomation and SupervisionㆍSafety and Condition MonitoringㆍHVAC & PumpsㆍRefrigerationㆍSmall Industrial MotorsㆍFansㆍLighting

ApplicationsㆍCurrent transformer and RMS

circuit in a single case

ㆍChoice of primary current ranges: 5 to 250A RMS

ㆍChoice of standard output types: 4-20mA, 0-5V

ㆍAccuracy: <2% of nominal primary current

ㆍBandwidth: 1kHz

Main characteristicsㆍHigh isolation between primary

and secondary circuitsㆍCompact caseㆍ

ㆍEasy installation

AdvantagesㆍTrue-RMS

(Bipolar DC in => Unipolar DC out) ㆍActive 0-5V DC output or

ㆍActive 4-20mA output

ㆍSingle power supply (24V)

ㆍOperating range: -20°C to +60°CㆍIsolation test voltage :

3.5kV RMS / 50Hz / 1minㆍSensing aperture :

21mmㆍUL94-V0 recognized materials

Features

AC/DC (INPUT) DC(OUTPUT)

Rated Current (A) 5, 10, 20, 25, 50, 75, 100, 150, 200, 250

Linear DC voltage output (True-RMS)

Active Current Source output (True-RMS)

Model Output Electrical Data

JM21XH-XXX-V

JM21XH-XXX-RMS

0-5V DC

4-20mA DC

Split CorePanel

Din Rail Mounting

Page 24: Hall effect current sensor 모바일용 · AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power

Split CoreOn PrimaryFastening

24

One touch clamp structureIsolation measurement± 15V(25mA) power supply

How to use

Core’s hysteresis occurs O point variation in proportion to its volume after over current. Output value includes each variation points so we recommend that actual range as over 5% space than rating, not over max current consecutively.

MODEL

Rating currentSaturation current

Output voltage

Output linearityPower supply

di/dt response timeOutput temperature

character

Operating ConditionStorage Condition

Insulationwithstand voltage

±4 V, 1% at rated current RL=10KΩ

JS10NH- 005

5A7.5AT

JS10NH- 010

10A15AT

JS10NH- 015

15A22.5AT

JS10NH- 020

20A30AT

JS10NH- 025

25A37.5AT

JS10NH- 050

50A75AT

75A112.5AT

JS16NH- 005

JS16NH- 010

JS16NH- 015

JS16NH- 020

JS16NH- 025

JS16NH- 050

JS16NH- 075

JS16NH- 100

100A

JS24NH- 200

200A

JS24SH- 250

250A150AT 250AT

JS24NH- 150

150A225AT 625AT

JS24SH- 300

300A625AT

JS36SH- 500

500A625AT

JS36SH- 400

400A625AT

±20 mV max

3 μ sec (Typ.) at di/dt = F.S/μ Sec.

± 0.2% / °C (Typ.) ± 0.1% / °C (Typ.)

AC 1500V / 1min.

±1% rated current±15 V (±5%) 25mA

Insulation resistance DC 500V / 500MΩ max-25°C~+75°C, 85 % RH non-condensing-35°C~+90°C, 85 % RH non-condensing

Noise level±30 mV max Less than

< 20mVp-p < 10mVp-p

3 4

1 2

P2P1

Features

Specification

Caution

JS10 / 16 / 24 / 36 XH Hall Sensor series, applying with accurate laminating core split technology and Open Loop technology iSAST OPEN HCS, JSXXXH Series designed for strong durability and improves both existed error in low current and error occurred by ‘external vibration and shock’ to minimize tolerance on cutting cross section of core. As compact one-touch split structure, it oers best solution for security and fast installation on high frequency monitoring device instead of cutting power line. Rated current is DC5A-500A, it satises with accura-cy 1.0 and it certies with security accreditation IEC61010-1, UL61010-1 and EN61010-1 as ocial document.

JS10 / 16 / 24 / 36 XH Hall Sensor series, applying with accurate laminating core split technology and Open Loop technology iSAST OPEN HCS, JSXXXH Series designed for strong durability and improves both existed error in low current and error occurred by ‘external vibration and shock’ to minimize tolerance on cutting cross section of core. As compact one-touch split structure, it oers best solution for security and fast installation on high frequency monitoring device instead of cutting power line. Rated current is DC5A-500A, it satises with accura-cy 1.0 and it certies with security accreditation IEC61010-1, UL61010-1 and EN61010-1 as ocial document.

Open-Loop Current SensorsJSXXXH-XXX Series

Page 25: Hall effect current sensor 모바일용 · AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power

Split CoreOn

PrimaryFastening

25

Open-Loop Current SensorsJSXXXH-XXX Series

COM INPUT

–15V +15V OV

(COM)

10A/div

1V/div

10A/div

1V/div

12

8

4

0

-4

-8

-12-150 -100 -50 0 50 100 150

(V)

lo (A)

(lo=5A)(lo=5A)

[Hz]

(mV)

10 100 1000 104 105

0

200

400

600

800

1000

1200

1400

Unit : mm

Model

J S 1 0 X H -X X X

J S 1 6 X H -X X X

J S 2 4 X H -X X X

J S 3 6 X H -X X X

A

40.5

45

65

82.4

B

23

26

37.5

48

C

23.7

30

45

57.1

D

26.6

31.6

33.7

40.2

E

14.5

18.8

21.1

21.1

Ød

10

16

24

36

Output Wave-1Output Wave-1 Output Wave-2Output Wave-2

Output Voltage CharacteristicOutput Voltage Characteristic Frequency CharacteristicFrequency Characteristic

A

B

D C

E

Ød

COM INPUT

–15V +15V OV

(COM)

Red

Green

White

Black

Dimension

Graph

Connection Diagram

00

30

10

20

50

40

05

25

55

35

4515

Prɪˈsɪʒən Laches is

Page 26: Hall effect current sensor 모바일용 · AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power

Split CoreOn PrimaryFastening

26

How to use

• PC spring, secure locking hinge, one-touch structure make easy to install to the existent equipments such as a power distribution boards.• Isolated plastic case recognized according to UL94-V0

Features

Specification

• Power Metering.• Sub-metering for Building; Energy eciency monitoring, consumption analysis, and cost allocation.• Power Quality Monitoring for Distribution System Equipment.• Condition Monitoring for Conveyers, Pumps, etc.• Hybrid Inverter for Home Energy Storage.• Distributed Measurement Systems.

Applications

JPS10 / 20 / 33 / 52H Hall Sensor series, applying with accurate laminating core split technology and Open Loop technology PQ-CT OPENJPSXXH Series designed for strong durability and improves both existed error in low current and error occurred by ‘external vibrationand shock’ to minimize tolerance on cutting cross section of core. As compact one-touch split structure, it oers best solution for securityand fast installation on high frequency monitoring device instead of cutting power line. Rated current is DC5A-1200A, it satises with accuracy 1.0 and it certies with security accreditation IEC61010-1, UL61010-1 and EN61010-1 as ocial document.

JPS10 / 20 / 33 / 52H Hall Sensor series, applying with accurate laminating core split technology and Open Loop technology PQ-CT OPENJPSXXH Series designed for strong durability and improves both existed error in low current and error occurred by ‘external vibrationand shock’ to minimize tolerance on cutting cross section of core. As compact one-touch split structure, it oers best solution for securityand fast installation on high frequency monitoring device instead of cutting power line. Rated current is DC5A-1200A, it satises with accuracy 1.0 and it certies with security accreditation IEC61010-1, UL61010-1 and EN61010-1 as ocial document.

Open -Loop technology PQ-CT JPSXXH Series

MODEL

Rating currentSaturation current

Output voltage

Output linearityPower supply

di/dt response timeOutput temperature

character

Operating ConditionStorage Condition

Insulationwithstand voltage

±4 V, 1% at rated current RL=10KΩ

JPS10H- 005

5A7.5AT

JPS10H- 010

10A15AT

JPS10H- 015

15A22.5AT

JPS10H- 020

20A30AT

JPS10H- 025

25A37.5AT

JPS10H- 050

JPS10H- 075

JPS10H- 100

50A75AT

75A112.5AT

JPS20H- 050

JPS20H- 075

JPS20H- 100

JPS20H- 150 JPS20H

- 200JPS20H

- 250100A

JPS33H- 200

200A

JPS33H- 250

250A150AT 250AT

150A225AT 625AT

JPS33H- 300

300A625AT

JPS33H- 500

500A 600A 800A 1000A 1200A625AT 900AT 1200AT 1400AT 1400AT

JPS33H- 400

JPS52H- 300

JPS52H- 500

JPS52H- 600

JPS52H- 800

JPS52H- 1000

JPS52H- 1200JPS52H

- 400400A625AT

±20 mV max ( JPS20H, JPS33H, JPS52H )

3 μ sec (Typ.) at di/dt = F.S/μ Sec.

± 0.2% / °C (Typ.) ± 0.1% / °C (Typ.)

AC 4000V / 1min.

±1% rated current±15 V (±5%) 25mA

Insulation resistance DC 500V / 500MΩ max-25°C~+75°C, 85 % RH non-condensing-35°C~+90°C, 85 % RH non-condensing

Noise level

±30 mV max Less than (JPS10H)

< 20mVp-p (JPS10H)

< 10mVp-p ( JPS20H, JPS33H, JPS52H )

3 4

2

P2P1

1

Benefits• Small-size, light-weight• Simple Installation• Over-Voltage protection circuit is installed.

JPS33H-300300A:±4VDC

JPS33H-300300A:±4VDC

Page 27: Hall effect current sensor 모바일용 · AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power

Split CoreOn

PrimaryFastening

Unit : mm

Model

J P S 1 0 H - X X X

J P S 2 0 H - X X X

J P S 3 3 H - X X X

J P S 5 2 H - X X X

A

48

47.7

49

64

B

35

35

36

41

C

48

58

77.5

103.5

D

61

71.5

96

125

E

10

20

33

52

COM INPUT

–15V +15V OV

(COM)

10A/div

1V/div

10A/div

1V/div

12

8

4

0

-4

-8

-12-150 -100 -50 0 50 100 150

(V)

lo (A)

(lo=5A)(lo=5A)

[Hz]

(mV)

10 100 1000 104 105

0

200

400

600

800

1000

1200

1400

Output Wave-1Output Wave-1 Output Wave-2Output Wave-2

Output Voltage CharacteristicOutput Voltage Characteristic Frequency CharacteristicFrequency Characteristic

COM INPUT

–15V +15V OV

(COM)

Red

Green

White

Black

Graph

Connection Diagram

27

Open-Loop technology PQ-CT JPSXXH Series

Dimension

B

A D

EC

Page 28: Hall effect current sensor 모바일용 · AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power

Specifi cation

4

1

2

3

Connector

Detail A1 2 43

ConnectorTerminal No.

Detail B

Features

Dimensions(unit : mm)

1

2

3

4

+V CC

V OUT

R L=10kΩ

GND

-V CC

Core=Silicon steel plate

1Terminal PinFunction + 15V

2– 15V

3Output

40 V

Panel mountingIndustrial temperature rangeUL94V0 complianceCE and RoHS available

Ø5

106

134.

6

208

4090

25.5

104.

5

12

3120 5

112

56188.5

Ø5.5

1 4

Connection

Open-Loop Current SensorsJHAO-XXXXSD(A/B) SeriesPanel

Mounting

Split Core

MODEL

Rating currentSaturation current

Output voltage

Output linearityPower supply

Di/dt response timeOutput temperature

character

Operating ConditionStorage Condition

Insulationwithstand voltage

±4 V, 0.5% at rated current RL=10KΩ

±20 mV

± 0.1% / °C (Typ.)

AC 4000V / 1min.

±0.5% rated current±15 V (±5%)

temperature character

Hysteresiserror

± 1mV / °C (Typ.)

25mV(IF=F.S) Less than 25mV

Insulation resistance DC 500V / 500MΩ max-10°C ~ +70°C-25°C ~ +85°C

JHAO-1000SD(X)

JHAO-1500SD(X)

JHAO-2000SD(X)

JHAO-2500SD(X)

JHAO-3000SD(X)

JHAO-4000SD(X)

JHAO-5000SD(X)

±1000 ±1500 ±2000 ±2500 ±3000 ±4000 ±5000

±2000 ±3000 ±4000 ±5000 ±6000 ±8000 ±8000

Page 29: Hall effect current sensor 모바일용 · AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power

PCBMounting

Vcc=±12V @ ±10mA : 30Ω ~ 190Ω@ ±14mA : 30Ω ~ 100Ω

Vcc=±15V @ ±10mA : 100Ω ~ 350Ω@ ±14mA : 100Ω ~ 190Ω

29

Closed-Loop Voltage SensorJHVC-A25

Specification

Dimensions(unit : mm)

Features

+M

--

+

0V

+HT

- HT RN

-VN

+VN

IN R1

Primarycurrent

Excellent accuracy and linearityLow response time thermal driftHigh tolerance to external interferenceHigh bandwidth

ModelNominal inputMeasuring rangeMeasuring resistor(Vs = ±12...15V)

Output current(Im)Accuracy (Ta=+25°C)Turns ratioSupply voltages(Vs)Current consumption

Oset current (Ta=+25°C)

10mArms (10V...500V)JHVC-A25

0~±14mA

±25mAIN±1.0%2500:1000±12V~±15V (±5%)10mA+Im2.5kV RMS/ 50Hz/1min.Isolation voltage±0.2mA Max for primary current IN=0±0.2mA Typical; ±0.3mA Max (0°C~+70°C)Temperature drift< 0.1%Linearity< 10μsResponse time0~20kHzOperating Frequency range0°C~+70°COperating temperature-40°C~+85°CStorage temperature110Ω (Ta=+70°C)Secondary resistor250Ω (Ta=+70°C)Primary resistance22gWeight

27.4

15.24

29.8

21.2

3.445.44 20.32

2X7.62

5-Ø10

-

+

M

+HT

-HT

18

22

JHVC-A25-HT

+HT

+M

-

Connection

JHVC

-A25

JD12

0612

-HT

+HT

+M

-

Page 30: Hall effect current sensor 모바일용 · AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power

PanelMounting

30

Electrical characteristics

General data

Voltage transducer uses special Isolation Barrier technology to measure AC and DC or Pulsed voltages. The primary input voltage and the output signal is highly electric isolated. It can be used in Power Utility, Converters, Traction, Telecom, Oil & Gas, and New energy elds.

Features

AC, DC, Pulsed voltage measurement Included primary resistor Good linearity Galvanic isolation between primary and secondary circuitLow power consumption High immunity to external interference Low thermal drift Higher voltage can measure than EVS30

Primary nominal voltage (Vrms)Primary voltage, measuring range (Vrms)Secondary Current output

Accuracy (Ta=+25°C)Linearity errorPower supply voltage (± 15V)Oset current (TA = +25 ˚C)

Frequency bandwidth

150% x VPN 50, 125, 150, 250, 500, 750, 1000, 1500, 2000, 2500, 3000 V

50 mA (EVS30-XXXX-A)

≤ 0.5%≤ 0.1%PN (± 5%)

6.0 kV

≤ ± 0.15 mAResponse time ≤ 10 μs

DC-1KHZ(-3dB) Current consumption 50mA (for current output: + IS )Load resistance ≤ 150Ω(for current output) or >5KΩ(for voltage output) Primary input resistance 60MΩIsolation test (50Hz,1min)

VPN

VP

RL

ISN

Secondary Voltage output 0 ± 5V (EVS30-XXXX-V)VSN

VC

IC

VD

XG

RP

εL

I0

f

TR

Ambient operating temperature Ambient storage temperature MassStandardsAmbient operating humidity Case material

-50 °C... +90 °C *-40 °C... +85 °C

350gEN5017820-90% RH According to UL94-V0

TA

TS

WST

HA

Digital Voltage SensorEVS30-XXXX-X Series

Page 31: Hall effect current sensor 모바일용 · AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power

PanelMounting

31

Digital Voltage SensorEVS30-XXXX-X Series

Connection diagram

Dimensions (mm)

Output figure

M5 48 15

48.3 17

5.2

H+ H-

125.3

138

1515

3.3

Ø6.5

63

+ M -

E

+HV+Vc

0 V

-Vc

+

M

--HV

Is Rm

Isolationbarrier

+ VPN

- VPN

-50

50

Output in mA

0±50mA output

+ VPN

- VPN

-5

5

00

Output in V

0±5V output

± 1mm

Generaltolerance

BottomSide

: 2 x Ø 6.5(mm): 2 x Ø 4.8(mm)

Input Output

: 2 x M5: 2 x M5

Terminals Fastening

50 mA (EVS30-XXXX-A)0 ± 5V (EVS30-XXXX-V)

Page 32: Hall effect current sensor 모바일용 · AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power

Voltage transducer uses special Isolation Barrier technology tomeasure AC and DC or Pulsed voltages and True RMS treatment, theoutput signal can be standard RMS voltage or current. The primaryinput voltage and the output signal is highly electric isolated. It canbe used in Power Utility, Converters, Traction, Telecom, Oil & Gas,and New energy elds.

Features

AC, DC, Pulsed voltage measurement Included primary resistor Good linearity Galvanic isolation between primary and secondary circuitLow power consumption High immunity to external interference Low thermal drift Higher voltage can measure than EVS30

Electrical characteristics

General data

PanelMounting

32

Digital Voltage SensorEVS30A-XXXX series

Primary nominal voltage (Vrms)

Primary voltage, measuring range (Vrms)

Secondary Current output

Secondary Voltage output

Accuracy (Ta=+25°C)

Linearity error

Power supply voltage (± 5%)

current (TA = +25 ˚C)

Response time

Frequency bandwidth

Current consumption

Load resistance

Isolation test (50Hz,1min)

VPN

VP

ISN

VSN

XG

εL

VC

I0

TR

f

IC

RL

VD

50, 150, 250, 500, 1000, 1500, 2000, 2500, 3000 V

150% x VPN

DC0-20mA, DC4-20mA

DC0-5V, DC0-10V

0.5%

≤ 0.1%

24Vdc

≤50mV / ≤±0.08mA

≤ 150mS

DC,20HZ-1KHZ(-3dB)

50mA (for current output:+ Is)

≤350Ω(for current output) or >5KΩ(for voltage output)

6.0 kV

Ambient operating temperature

Ambient storage temperature

Mass

Standards

Ambient operating humidity

Case material

TA

TS

W

ST

HA

-40 °C... +85 °C

-50 °C... +90 °C

350g

EN50178

20-90% RH

According to UL94-V0

Page 33: Hall effect current sensor 모바일용 · AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power

Connection diagram

Dimensions (mm)

Output figure

PanelMounting

33

Digital Voltage SensorEVS30A-XXXX series

M5 48 15

48.3 17

5.2

H+ H-

125.3

138

1515

3.3

Ø6.5

63

+ M -

E

± 1mm

Generaltolerance

BottomSide

: 2 x Ø 6.5(mm): 2 x Ø 4.8(mm)

Input Output

: 2 x M5: 2 x M5

Terminals Fastening

+HV+Vc

0 V

-Vc

+

M

--HV

Is Rm

Isolationbarrier

DC0-5V output

DC4-20mA output

DC0-10Voutput

Page 34: Hall effect current sensor 모바일용 · AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power

34

Checklist for Customers

Date

Company name

Location

Demander (name/dept./position)

Tel.

Fax.

E-mail

QM Requirement

Project name

Application

Min. lot Q'ty

Annual estimated Q'ty

Target price

Q'ty of samplesrequired for

Contents

--

--

K pcs-

K pcs-

(USC/EUR/JPY)-

pcs-

--

-

Application

Nominal value

Power supply

di/dt to be followed

Preferred output

Turns ratio

Accuracy class

Overload requirement

Operating Temperature range

Operating Frequency

Dielectric withstand 2'nd-Earth

Dimensions

Primary Connection

Terminal Structure

Other requirements (if any, Diagram required for)

Current Monitoring Other( ) Energy Monitoring

+ ±

Max. ( )Min. ( )

( )rms

( )A/

Primary : Second ( : )

( )%

( )Hz

AC( )kV / 1min.

Inner Dia. - ( )mm, Width x Length x Height - ( x x )mm

( )% of Max. Primary Current

mA/A mV/A mA/A mV/A

Through hole Busbar Other

PCB Molex Cable

Page 35: Hall effect current sensor 모바일용 · AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power