16
OctOBER 2008 CI/SfB Uniclass L351:P4142 EPIC C21: X442 (28) Hh2 HADLEY STEEL FRAMING for LIGHTWEIGHT STEEL FRAMING IN CONSTRUCTION Absolute Steel Framing Ltd 123 West Bromwich Street, Oldbury, West Midlands B69 3AZ, England. Telephone: +44 (0) 121 555 1385 Fax: +44 (0) 121 555 1386 Email: [email protected] Website: www.absolutesteelframing.co.uk ® HADLEY STEEL FRAMING, UltraZED, UltraBEAM, UltraPRO., UltraCAM. and Slip-Klip are Registered Trade marks of Hadley Industries plc. In accordance with the manufacturers’ policy of continuous improvement, we reserve the right to alter specifications without prior notice. Whilst every precaution has been taken to ensure the accuracy of data, information or recommendations herein no liability in respect of such data, information or recommendations whether given negligently or otherwise can be accepted by the company. Products and their associated technical specifications displayed in this publication are the subject of patent, design and other intellectual property rights. HADLEY STEEL FRAMING HADLEY STEEL FRAMING for LIGHTWEIGHT STEEL FRAMING IN CONSTRUCTION

Transcript of HADLEY STEEL FRAMING - The Future Build · 2 3. HADLEY STEEL FRAMING ™ is a major source of light...

OctOBER 2008

CI/SfB

UniclassL351:P4142

EPICC21: X442

(28) Hh2

HADLEYSTEELFRAMING

f o rL IG H TW E IGHTST EEL FRAM ING IN CONST RU C T IO N

Absolute Steel Framing Ltd123 West Bromwich Street, Oldbury, West Midlands B69 3AZ, England.

Telephone: +44 (0) 121 555 1385Fax: +44 (0) 121 555 1386Email: [email protected]: www.absolutesteelframing.co.uk

® HADLEY STEEL FRAMING, UltraZED, UltraBEAM, UltraPRO., UltraCAM. and Slip-Klip are Registered Trade marks of Hadley Industries plc.In accordance with the manufacturers’ policy of continuous improvement, we reserve the right to alter specifications without prior notice.Whilst every precaution has been taken to ensure the accuracy of data, information or recommendations herein no liability in respect of such data,information or recommendations whether given negligently or otherwise can be accepted by the company.Products and their associated technical specifications displayed in this publication are the subject of patent, design and other intellectual property rights.

HADLEYSTEELFRAMING

HADLEYSTEELFRAMING

f o rL I GHTWE IGH T STEEL FRAMING I N CONST R U C T ION

2812027 ABSOLUTE STEEL FRAMING 08.qxd 8/1/09 13:15 Page 2

bdunthor
Text Box
REMOVE THIS LOGO...
bdunthor
Text Box
HADLEY INDUSTRIES MIDDLE EAST P.O. Box 61322, Dubai, United Arab Emirates. Telephone: +97 14 883 3811 Fax: +97 14 883 3973 E-mail: [email protected] Website: www.hadleygroup.ae

28

S Y S T EMSPECIFICATION

SPECIFICATION NOTATION FOR HADLEY STEEL FRAMING PRODUCTS

PRODUCTS

1.1 All HADLEY STEEL FRAMING cold roll-formed section is manufactured from pre-galvanised “structural grade” steel to BS EN 10326:2004 and complying tominimum specified values.

1.2 All cold roll-formed HADLEY STEEL FRAMING sections shall be determined by structural calculation and supplied byHADLEY STEEL FRAMING, 123, West Bromwich Street, Oldbury, West Midlands B69 3AZ.

1.3 Unless stated otherwise structural calculations are in accordance with BS5950-5: 1998. Loadings are determined by BS6399.

INSTALLATION AND FABRICATION

2.1 The installer shall submit typical construction details for approval to the Architect or Engineer prior to fabrication and installation of materials.

2.2 All framing components shall be cut square unless an angular fit is required between components.

2.3 Service slots where specified must not be positioned less than 600mm from stud ends or 300mm from joist ends.

2.4 All fixings shall be in accordance with structural calculations and as indicated on the drawings.

2.5 Track section shall be fixed to a uniform and level bearing face and abutting track section shall be fixed to a common structural element.

2.6 Track section shall not extend more than 25% of its section web width beyond the bearing surface to which it is attached.

2.7 Stud sections shall be plumb and fixed to track sections in accordance with manufacturer's recommendations.

2.8 Openings shall be formed to include cills, lintels, jambs and supporting studs as detailed.

2.9 Where necessary to achieve a satisfactory structural framework in accordance with the drawing the use of temporary bracing may be necessary.

2.10 All Slip-Klips, blocking and bracing components as shown on the drawing are to be provided to resist lateral and torsional buckling of studs or joists.

2.11 Splicing of studs is forbidden unless by prior agreement and in accordance with HADLEY STEEL FRAMING recommendations.

2.12 Floor joists shall line through with vertical wall studs and where required joist reinforcement stiffeners should be included in accordance with structuralcalculations and as indicated on the drawings.

CLADDING AND INSULATION

3.1 Internal linings should be selected and fixed in accordance with the manufacturer's recommendations to ensure the specified performance for acoustic, fire,load bearing and thermal is achieved.

3.2 Insulation should be selected and fixed in accordance with the manufacturer's recommendations to ensure the specified performance is achieved. It should beof a robust nature and sufficiently attached to the structure to maintain its specified design performance during and after the construction process.

3.3 Masonry should be tied back to wall studs using proprietary stainless steel wall ties in accordance with structural calculations and manufacturer'srecommendations.

32 PAGE HADLEY STEEL FRAMING OCT 08 (SSL) 20/10/08 15:04 Page 32

1

HADLEY STEEL FRAMING™ COMPONENTS

REFERENCE PAGE No.

Introduction 2-3

System Overview 4-9

System Applications

Non-continuous Infill Framing 12-15

Construction Methods 16-17

Continuous External Framing 20-21

Load Bearing Framing 22-23

Partition Walling 24-25

Auditorium Seating Support 26

Components & Ancillary Items 27

Specifications 28

OUR MISSION STATEMENT:-“WE WILL EXCEED OUR CUSTOMERS’EXPECTATIONS BY WORKING TOGETHERPROFITABLY TO IMPROVE QUALITY AND SERVICETHROUGH INVESTMENT IN PEOPLE ANDTECHNOLOGY’.

SHAPING THE FUTURE IN METAL

32 PAGE HADLEY STEEL FRAMING OCT 08 (SSL) 20/10/08 14:13 Page 4

2 3

HADLEY STEEL FRAMING™ is a major sourceof light gauge steel framing within the UKconstruction sector and a development of theThe Hadley Group one of Europe’s foremostproducers of cold roll-formed metal sections and arespected name in roll-forming innovation.

With hundreds of successful installations carried outby a nationwide network of experienced installers,HADLEY STEEL FRAMING systems has acquired anenviable reputation as the ‘approachable experts’ inlight gauge steel framing methodology. Our flexibleapproach to providing clients with solutions to theirconstruction problems has resulted in a rapid rise insales and HADLEY STEEL FRAMING is now thepreferred choice of many installers, contractors and designers.

Accurate profiles manufactured to exactingstandards and delivered to meet the tightest of buildprogrammes result in faster installation and lesswaste. A dedicated technical support team,comprising of qualified, experienced engineers anddesigners, are on hand to ensure that projects aredelivered on time, within budget and to specification.

Structural calculations and project specificworking drawings are provided and underwrittenby Professional Indemnity and Product LiabilityInsurance thus offering clients peace of mind andguaranteeing quality. HADLEY STEEL FRAMINGComponents have been awarded British Board ofAgrément Certification and are manufactured inaccordance with Quality Assurance standardISO9001:2000.

HADLEY STEEL FRAMING may be specified anddesigned for use as both load bearing light gaugesteel framing panels and as non-load bearing siteconstructed infill walling. Other applicationsinclude High Bay Partition Walling, lightweightseating support structures, modular constructionand internal as well as mid-rise external freestanding structures. Whatever the preferred solution,by specifying steel, clients can be assured they areutilising a lightweight quality product that minimisesenvironmental impact. Steel is a fully recyclablematerial with a proven pedigree in constructionprojects.

The Hadley Group is one of Europe’sleading manufacturers of cold rolled sections andallied products.

Operating from purpose built premises in theheart of the industrial West Midlands in the UnitedKingdom, The Hadley Group of companiesare dedicated to the provision of matchlessstandards of service, quality, innovation andtechnical expertise.

The integration of advanced research anddevelopment with in-house tool manufacture andthe construction of its own rolling machines hasearned The Hadley Group its reputation asa major force in cold roll-formed technology.

Components designed and engineered bycompanies within The Hadley Group aremanufactured for use in all types of industry fromautomotive and construction through to aerospace.

Advanced computer aided design technology isused in the development and production of a widerange of products setting high standards ofperformance and reliability.

HADLEY STEEL FRAMING productsare manufactured from re-cyclablesteel which is itself manufacturedusing re-cycled material in accordance

with steel industry standards. Bolted and mechanicalconnections result in environmentally friendlyconstruction methods - simplifying and assisting LifeCycle Analysis (LCA) targets for building design.

32 PAGE HADLEY STEEL FRAMING OCT 08 (SSL) 20/10/08 14:13 Page 6

26 27

SYSTEMAPPLICATION

auditoriumseating support

SYSTEMAPPLICATION

components andancillary items

HADLEY STEEL FRAMINGCOMPONENTS

Channel and track section sizes range from 70mm to305mm deep with gauges ranging from 1.2mm to2.5mm thick. Service holes and other punchingconfigurations are included as specified. Full sectionspecification is available upon request and fullyitemised in all HADLEY STEEL FRAMING structuraldesigns.

Section may be manufactured specific to customerand project requirements; however some items suchas track, angle and bracing strap are normallysupplied in stock lengths for working on site.

Lead times are measured in days – rarely weeks and,when situations demand it, occasionally hours!All part of the quality service afforded toHADLEY STEEL FRAMING clientele

ACCESSORIES AND ANCILLARYITEMS

A comprehensive range of accessories including ourpatented Slip-Klips™ and FC cleats are availableex-stock for next day delivery. Subject to projectrequirements it is often necessary to design specificancillary items such as cleats, brackets, supportingsteel and structural steel members. If required, andsubject to availability and scope of manufacture;such items may be supplied as part of theHADLEY STEEL FRAMING package thus offeringclients a single source supply for their light gaugesteel framing package.

FASTENERS

HADLEY STEEL FRAMING light gauge steel framingcomponents are suitable for use in manyconstruction applications. Typically they areinter-connected or connected to either hot rolledsteel or a concrete primary structure. Fasteningmethods include self drilling and/or self tappingscrews, powder actuated direct fastenings, resin orexpansion anchors, bolts, self piercing rivets andclinching. Hadley’s close association with leadingfastener suppliers enables us to offer assistance inthe site application of fasteners - includingpre-installation training and structural testing.

Fastenings and all applicable recommendations formpart of our structural design package and are integralto the final design specification issued prior toinstallation. Whenever practical and always subjectto structural design considerations, Hadley’sengineers will work closely with clients andinstallers to accommodate their preferred fastenersupplier(s).

All HADLEY STEEL FRAMING cold roll-formedsection is manufactured from pre-galvanised“structural grade” steel to BS EN 10326:2004 andcomplying to minimum specified values.

A lightweight and highly versatile solution to seatingsupport structures. Eminently suited to new build orrefurbishment projects that have limited site accessor restrictions on foundation loading.

The support structure utilises cold roll-formedcolumns and beams supplied as individualpre-engineered components ready for site assembly.

Lightweight cold roll-formed sections combined withfabricated hot rolled steel extends the scope of thissolution to larger structures.

Project specific design criteria may be satisfied byspecifying either a timber or a steel and concretecomposite floor deck.

LIPPED ‘C’ SECTION STUD

PLAIN ‘C’ SECTION TRACK

32 PAGE HADLEY STEEL FRAMING OCT 08 (SSL) 20/10/08 14:58 Page 30

bdunthor
Text Box
Operating from purpose built premises in the heart of the industrial West Midlands in the United Kingdom, the Hadley group of companies are dedicated to the provision of matchless standards of service, quality, innovation and technical expertise. The integration of advanced research and development with in-house tool manufacture and construction of its own roll forming machines has earned Hadley Industries plc its reputation as a major force in Cold Rollforming technology Components designed and enginered by companies within the Hadley Group are manufactured for use in all types of industry from agriculture through construction to automotive. Advanced computer aided design technology is used in the development and production of a wide range of products setting high standards of performance and reliability. The Hadley Group has been established in the Middle East for over 20 years, operating from a purpose built factory in Jebel Ali, Dubai. It produces a comprehensive range of cold rolled formed sections for the construction industry including dry walling and ceiling sections, electrical cable management systems, PVC-u window reinforcement and structural steel framing. We operate a Quality Management System which complies with the requirements of ISO 9001:2008

26 27

SYSTEMAPPLICATION

auditoriumseating support

SYSTEMAPPLICATION

components andancillary items

HADLEY STEEL FRAMINGCOMPONENTS

Channel and track section sizes range from 70mm to305mm deep with gauges ranging from 1.2mm to2.5mm thick. Service holes and other punchingconfigurations are included as specified. Full sectionspecification is available upon request and fullyitemised in all HADLEY STEEL FRAMING structuraldesigns.

Section may be manufactured specific to customerand project requirements; however some items suchas track, angle and bracing strap are normallysupplied in stock lengths for working on site.

Lead times are measured in days – rarely weeks and,when situations demand it, occasionally hours!All part of the quality service afforded toHADLEY STEEL FRAMING clientele

ACCESSORIES AND ANCILLARYITEMS

A comprehensive range of accessories including ourpatented Slip-Klips™ and FC cleats are availableex-stock for next day delivery. Subject to projectrequirements it is often necessary to design specificancillary items such as cleats, brackets, supportingsteel and structural steel members. If required, andsubject to availability and scope of manufacture;such items may be supplied as part of theHADLEY STEEL FRAMING package thus offeringclients a single source supply for their light gaugesteel framing package.

FASTENERS

HADLEY STEEL FRAMING light gauge steel framingcomponents are suitable for use in manyconstruction applications. Typically they areinter-connected or connected to either hot rolledsteel or a concrete primary structure. Fasteningmethods include self drilling and/or self tappingscrews, powder actuated direct fastenings, resin orexpansion anchors, bolts, self piercing rivets andclinching. Hadley’s close association with leadingfastener suppliers enables us to offer assistance inthe site application of fasteners - includingpre-installation training and structural testing.

Fastenings and all applicable recommendations formpart of our structural design package and are integralto the final design specification issued prior toinstallation. Whenever practical and always subjectto structural design considerations, Hadley’sengineers will work closely with clients andinstallers to accommodate their preferred fastenersupplier(s).

All HADLEY STEEL FRAMING cold roll-formedsection is manufactured from pre-galvanised“structural grade” steel to BS EN 10326:2004 andcomplying to minimum specified values.

A lightweight and highly versatile solution to seatingsupport structures. Eminently suited to new build orrefurbishment projects that have limited site accessor restrictions on foundation loading.

The support structure utilises cold roll-formedcolumns and beams supplied as individualpre-engineered components ready for site assembly.

Lightweight cold roll-formed sections combined withfabricated hot rolled steel extends the scope of thissolution to larger structures.

Project specific design criteria may be satisfied byspecifying either a timber or a steel and concretecomposite floor deck.

LIPPED ‘C’ SECTION STUD

PLAIN ‘C’ SECTION TRACK

32 PAGE HADLEY STEEL FRAMING OCT 08 (SSL) 20/10/08 14:58 Page 30

2 3

HADLEY STEEL FRAMING™ is a major sourceof light gauge steel framing within the UKconstruction sector and a development of theThe Hadley Group one of Europe’s foremostproducers of cold roll-formed metal sections and arespected name in roll-forming innovation.

With hundreds of successful installations carried outby a nationwide network of experienced installers,HADLEY STEEL FRAMING systems has acquired anenviable reputation as the ‘approachable experts’ inlight gauge steel framing methodology. Our flexibleapproach to providing clients with solutions to theirconstruction problems has resulted in a rapid rise insales and HADLEY STEEL FRAMING is now thepreferred choice of many installers, contractors and designers.

Accurate profiles manufactured to exactingstandards and delivered to meet the tightest of buildprogrammes result in faster installation and lesswaste. A dedicated technical support team,comprising of qualified, experienced engineers anddesigners, are on hand to ensure that projects aredelivered on time, within budget and to specification.

Structural calculations and project specificworking drawings are provided and underwrittenby Professional Indemnity and Product LiabilityInsurance thus offering clients peace of mind andguaranteeing quality. HADLEY STEEL FRAMINGComponents have been awarded British Board ofAgrément Certification and are manufactured inaccordance with Quality Assurance standardISO9001:2000.

HADLEY STEEL FRAMING may be specified anddesigned for use as both load bearing light gaugesteel framing panels and as non-load bearing siteconstructed infill walling. Other applicationsinclude High Bay Partition Walling, lightweightseating support structures, modular constructionand internal as well as mid-rise external freestanding structures. Whatever the preferred solution,by specifying steel, clients can be assured they areutilising a lightweight quality product that minimisesenvironmental impact. Steel is a fully recyclablematerial with a proven pedigree in constructionprojects.

The Hadley Group is one of Europe’sleading manufacturers of cold rolled sections andallied products.

Operating from purpose built premises in theheart of the industrial West Midlands in the UnitedKingdom, The Hadley Group of companiesare dedicated to the provision of matchlessstandards of service, quality, innovation andtechnical expertise.

The integration of advanced research anddevelopment with in-house tool manufacture andthe construction of its own rolling machines hasearned The Hadley Group its reputation asa major force in cold roll-formed technology.

Components designed and engineered bycompanies within The Hadley Group aremanufactured for use in all types of industry fromautomotive and construction through to aerospace.

Advanced computer aided design technology isused in the development and production of a widerange of products setting high standards ofperformance and reliability.

HADLEY STEEL FRAMING productsare manufactured from re-cyclablesteel which is itself manufacturedusing re-cycled material in accordance

with steel industry standards. Bolted and mechanicalconnections result in environmentally friendlyconstruction methods - simplifying and assisting LifeCycle Analysis (LCA) targets for building design.

32 PAGE HADLEY STEEL FRAMING OCT 08 (SSL) 20/10/08 14:13 Page 6

54

S Y S T EMOVERVIEW

non continuousinfill framing

SYSTEMOVERVIEW

continuous externalframing

Lightweight, swift and dry construction alternative totraditional block work

Accepts virtually any external cladding materialincluding:

� Brick

� Stone

� Metal cladding

� Tiles

� Timber

� Insulated render

Site workable to facilitate construction tolerances

Easily adapts to changes in build programme

High structural, thermal and acoustic performance

Alternative method to or complimentary with infillconstruction method maximises available floor areaby moving wall construction outboard of primaryframe

Eminently suitable for refurbishment projects as wellas new build

Facilitates large variations in construction tolerances

32 PAGE HADLEY STEEL FRAMING OCT 08 (SSL) 20/10/08 16:49 Page 8

24 25

S Y S T EMAPPLICATION

partitionwalling

OPENING LINTEL CONSTRUCTION FLOOR TRACK

Short length of HADLEY STEEL FRAMING‘F’ Series section every 4th bay and at end pairs

B38 Bracingboth sides

Stud

HADLEY STEEL FRAMING ‘F’ Series Stud

HADLEY STEEL FRAMING‘F’ Series stud

Flush HeadScrews at 250mmapprox. centres and atStud/Track connection.

Tracksection

Track fixed to floor inaccordance with structuralcalculations.

DEFLECTION HEAD TRACK DETAILBLOCKING & BRACING

LATERAL RESTRAINTBLOCKING & BRACING

Heavy duty track 70mm deep

25mmDeflectionGap

B38Bracing

150mm

2 x Angle screw fixed topurlin / steelwork

Minimum stud bearing45mm

B38Bracing

B38Bracing

Flush head screws -minimum 5 per side

Stud section blockingcut as a ‘snug fit’between studs

HADLEY STEEL FRAMING - Partition Wallingis designed to perform as a single span partitionsuitable for use in industrial and commercial situationswhere a lightweight solution is preferred.

Low bearing loads minimise or obviate the need forfoundation or floor strengthening work. The result isshortened project time and reduced costs.

High performance levels in respect of fire, thermaland sound transference are obtainable when used inconjunction with a variety of propriety finishes.

Blocking and lateral restraint in accordance withstructural calculations.

32 PAGE HADLEY STEEL FRAMING OCT 08 (SSL) 20/10/08 14:56 Page 28

24 25

S Y S T EMAPPLICATION

partitionwalling

OPENING LINTEL CONSTRUCTION FLOOR TRACK

Short length of HADLEY STEEL FRAMING‘F’ Series section every 4th bay and at end pairs

B38 Bracingboth sides

Stud

HADLEY STEEL FRAMING ‘F’ Series Stud

HADLEY STEEL FRAMING‘F’ Series stud

Flush HeadScrews at 250mmapprox. centres and atStud/Track connection.

Tracksection

Track fixed to floor inaccordance with structuralcalculations.

DEFLECTION HEAD TRACK DETAILBLOCKING & BRACING

LATERAL RESTRAINTBLOCKING & BRACING

Heavy duty track 70mm deep

25mmDeflectionGap

B38Bracing

150mm

2 x Angle screw fixed topurlin / steelwork

Minimum stud bearing45mm

B38Bracing

B38Bracing

Flush head screws -minimum 5 per side

Stud section blockingcut as a ‘snug fit’between studs

HADLEY STEEL FRAMING - Partition Wallingis designed to perform as a single span partitionsuitable for use in industrial and commercial situationswhere a lightweight solution is preferred.

Low bearing loads minimise or obviate the need forfoundation or floor strengthening work. The result isshortened project time and reduced costs.

High performance levels in respect of fire, thermaland sound transference are obtainable when used inconjunction with a variety of propriety finishes.

Blocking and lateral restraint in accordance withstructural calculations.

32 PAGE HADLEY STEEL FRAMING OCT 08 (SSL) 20/10/08 14:56 Page 28

54

S Y S T EMOVERVIEW

non continuousinfill framing

SYSTEMOVERVIEW

continuous externalframing

Lightweight, swift and dry construction alternative totraditional block work

Accepts virtually any external cladding materialincluding:

� Brick

� Stone

� Metal cladding

� Tiles

� Timber

� Insulated render

Site workable to facilitate construction tolerances

Easily adapts to changes in build programme

High structural, thermal and acoustic performance

Alternative method to or complimentary with infillconstruction method maximises available floor areaby moving wall construction outboard of primaryframe

Eminently suitable for refurbishment projects as wellas new build

Facilitates large variations in construction tolerances

32 PAGE HADLEY STEEL FRAMING OCT 08 (SSL) 20/10/08 16:49 Page 8

6 7

S Y S T EMOVERVIEW

loadbearing

SYSTEMOVERVIEW

partitionwalling

On site construction or offsite factory panelisedmethods available

Lightweight structure reduces foundation loading

Suitable for single storey through to mid-rise projects

Particularly suitable for inclusion in refurbishment ornew build schemes requiring additional ‘pent-house’storeys to be added

Lightweight construction minimises or obviates floorstrengthening

Rapid installation developed for commercial, leisureand industrial projects

Suitable for refurbishment and new build schemes

Single span partition wall construction up to 17metres high

Excellent fire, thermal and acoustic performance

32 PAGE HADLEY STEEL FRAMING OCT 08 (SSL) 20/10/08 14:14 Page 10

22 23

S Y S T EMAPPLICATION

loadbearing

Track Section to top of stud wall orprimary support.

HADLEY STEEL FRAMING ‘F’ Series Floor Joistsscrew fixed back-to-back, as determined bystructural calculations.

HADLEY STEEL FRAMING ‘F’ Series Wall Stud(If appropriate).Floor Joists to line through with Wall Stud.

Track Section to top of stud wall orprimary support.

HADLEY STEEL FRAMING ‘F’ Series Floor Joistscontinuous over wall or stud wall.

HADLEY STEEL FRAMING ‘F’ Series Wall Stud (If appropriate).

HADLEY STEEL FRAMING ‘F’ Series Wall Stud (If appropriate).

Short length of joist section screw fixed to back of joist,as determined by structural calculations.

JOIST REINFORCEMENT

Joist web stiffening reinforces joists and prevents webcrippling at the point of load concentrations. N.B. Joist reinforcement is also required where thecentre of a 100 x 35mm service slot occurs less than300mm from the edge of bearing or concentrated load.

BRACING TO LOAD BEARING WALL(TYPICAL DETAIL)

LateralBracingB38.

Double studs inbraced bay

Blocking at ends of walland adjacent to wallopenings.Max distancebetweenblocking2400mm

Diagonal BracingB100 to one orboth sides of wall(dependantupon structuralcalculations)

TYPICAL WALL CONSTRUCTION USING BRICKCLADDING IN WARM FRAME CONSTRUCTION

Sheathing board asspecified (optional)

Thermal insulationas specified

Insulated sheathing boardas specified

Insulation asspecified

DPC

DPC

Insulation

Foundation Blinding

Ground floorslab

Stainless steel walltie system at600mmhorizontalcentres(typical) andverticalspacing asspecified.

Stainless steelwall tie systemat 600mmhorizontalcentres(typical) andverticalspacing asspecified.

Stud to window opening

Brickwork tie stud

Brick claddingon insulatedsheathingboard + insulationbetween studs.

Breather membranesecured as specified

Plasterboard(typical2x12.5mm oras specified)

Plasterboard(typical2 x 12.5mm oras specified)

TYPICAL WALL CONSTRUCTIONAND GROUND-BEARING SLAB

HADLEY STEEL FRAMING ‘F’ Series Floor joists to bebraced every 4th pair and at end pairs + lateral bracingstraps B38 fixed to lower flanges (only) at 2400mm max.unrestrained length. Joist top flange is restrained fromscrew fixing of floor decking.

HADLEY STEEL FRAMING ‘F’ Series Joistreinforcement screw fixed back-to-back,as determined by structural calculations.

Span x 0.12 orminimum320mm.

Span x 0.12 orminimum320mm.

CONTINUOUS MID-SPAN CONNECTION

NON CONTINUOUS END CONNECTION

CONTINUOUS MID-SPAN OR ENDCONNECTION

LATERAL BRACING

32 PAGE HADLEY STEEL FRAMING OCT 08 (SSL) 20/10/08 14:51 Page 26

22 23

S Y S T EMAPPLICATION

loadbearing

Track Section to top of stud wall orprimary support.

HADLEY STEEL FRAMING ‘F’ Series Floor Joistsscrew fixed back-to-back, as determined bystructural calculations.

HADLEY STEEL FRAMING ‘F’ Series Wall Stud(If appropriate).Floor Joists to line through with Wall Stud.

Track Section to top of stud wall orprimary support.

HADLEY STEEL FRAMING ‘F’ Series Floor Joistscontinuous over wall or stud wall.

HADLEY STEEL FRAMING ‘F’ Series Wall Stud (If appropriate).

HADLEY STEEL FRAMING ‘F’ Series Wall Stud (If appropriate).

Short length of joist section screw fixed to back of joist,as determined by structural calculations.

JOIST REINFORCEMENT

Joist web stiffening reinforces joists and prevents webcrippling at the point of load concentrations. N.B. Joist reinforcement is also required where thecentre of a 100 x 35mm service slot occurs less than300mm from the edge of bearing or concentrated load.

BRACING TO LOAD BEARING WALL(TYPICAL DETAIL)

LateralBracingB38.

Double studs inbraced bay

Blocking at ends of walland adjacent to wallopenings.Max distancebetweenblocking2400mm

Diagonal BracingB100 to one orboth sides of wall(dependantupon structuralcalculations)

TYPICAL WALL CONSTRUCTION USING BRICKCLADDING IN WARM FRAME CONSTRUCTION

Sheathing board asspecified (optional)

Thermal insulationas specified

Insulated sheathing boardas specified

Insulation asspecified

DPC

DPC

Insulation

Foundation Blinding

Ground floorslab

Stainless steel walltie system at600mmhorizontalcentres(typical) andverticalspacing asspecified.

Stainless steelwall tie systemat 600mmhorizontalcentres(typical) andverticalspacing asspecified.

Stud to window opening

Brickwork tie stud

Brick claddingon insulatedsheathingboard + insulationbetween studs.

Breather membranesecured as specified

Plasterboard(typical2x12.5mm oras specified)

Plasterboard(typical2 x 12.5mm oras specified)

TYPICAL WALL CONSTRUCTIONAND GROUND-BEARING SLAB

HADLEY STEEL FRAMING ‘F’ Series Floor joists to bebraced every 4th pair and at end pairs + lateral bracingstraps B38 fixed to lower flanges (only) at 2400mm max.unrestrained length. Joist top flange is restrained fromscrew fixing of floor decking.

HADLEY STEEL FRAMING ‘F’ Series Joistreinforcement screw fixed back-to-back,as determined by structural calculations.

Span x 0.12 orminimum320mm.

Span x 0.12 orminimum320mm.

CONTINUOUS MID-SPAN CONNECTION

NON CONTINUOUS END CONNECTION

CONTINUOUS MID-SPAN OR ENDCONNECTION

LATERAL BRACING

32 PAGE HADLEY STEEL FRAMING OCT 08 (SSL) 20/10/08 14:51 Page 26

6 7

S Y S T EMOVERVIEW

loadbearing

SYSTEMOVERVIEW

partitionwalling

On site construction or offsite factory panelisedmethods available

Lightweight structure reduces foundation loading

Suitable for single storey through to mid-rise projects

Particularly suitable for inclusion in refurbishment ornew build schemes requiring additional ‘pent-house’storeys to be added

Lightweight construction minimises or obviates floorstrengthening

Rapid installation developed for commercial, leisureand industrial projects

Suitable for refurbishment and new build schemes

Single span partition wall construction up to 17metres high

Excellent fire, thermal and acoustic performance

32 PAGE HADLEY STEEL FRAMING OCT 08 (SSL) 20/10/08 14:14 Page 10

8 9

S Y S T EMOVERVIEW

auditoriumseating support

SYSTEMOVERVIEW

detailing anddesign

Adaptable, lightweight, compact and high strengthconstruction methodology

Considerable reduction in support structure deadload

Small easily handled components are eminentlysuitable for installation in confined spaces orprojects with limited access

Speedy installation hastens project completion

Comprehensive, project specific ‘indicative design’assists in accurate tendering processes

Full structural calculations supplied as an integralpart of the order process

Detailed construction drawing service available tosuit project requirements

Warranted by Professional Indemnity (PI) andProduct Liability insurance

32 PAGE HADLEY STEEL FRAMING OCT 08 (SSL) 20/10/08 14:14 Page 12

20 21

S Y S T EMAPPLICATION

continuous externalframing system

HADLEY STEEL FRAMING - Continuous System iseminently suitable for buildings where the floor areaneeds to be maximised. Cleats are attached to the outerfaces of the floor slabs using fixings determined bystructural calculations.The continuous vertical sections are in turn attached tothe FC Series cleats using appropriate fixings locatedthrough slotted holes to facilitate deflection within thefloor slabs.Continuous infill system vertical sections are suppliedin full height lengths up to a maximum of 16 metres.Consideration should be given to site access, handlingand erection of long lengths of vertical sections. Wheresplicing of section is necessary, please consultHADLEY STEEL FRAMING for assistance.A number of Cill, Lintel and Jamb configurations areavailable to suit various design criteria.

HADLEY STEEL FRAMING - Continuous Systemis designed to carry lateral wind loads only. Theseloads are transferred from the outer cladding to theprimary structure via the cleat connections.

Vertical movement due to deflection within the floorslabs is catered for by slotted holes in the cleats,therefore external cladding weightmust be supported from a suitablestructural member designed to carrythese vertical loads. Where buildings exceed3 storeys in height additional vertical load supportsmay be necessary in accordance with structuralcalculations.

The lower end of the vertical stud sections shouldbe connected to a suitable support member tocarry the vertical weight of the stud section togetherwith attached insulation material, internal finishes,windows, exterior cladding (not masonry) etc. inaccordance with structural calculations.

32 PAGE HADLEY STEEL FRAMING OCT 08 (SSL) 20/10/08 14:49 Page 24

20 21

S Y S T EMAPPLICATION

continuous externalframing system

HADLEY STEEL FRAMING - Continuous System iseminently suitable for buildings where the floor areaneeds to be maximised. Cleats are attached to the outerfaces of the floor slabs using fixings determined bystructural calculations.The continuous vertical sections are in turn attached tothe FC Series cleats using appropriate fixings locatedthrough slotted holes to facilitate deflection within thefloor slabs.Continuous infill system vertical sections are suppliedin full height lengths up to a maximum of 16 metres.Consideration should be given to site access, handlingand erection of long lengths of vertical sections. Wheresplicing of section is necessary, please consultHADLEY STEEL FRAMING for assistance.A number of Cill, Lintel and Jamb configurations areavailable to suit various design criteria.

HADLEY STEEL FRAMING - Continuous Systemis designed to carry lateral wind loads only. Theseloads are transferred from the outer cladding to theprimary structure via the cleat connections.

Vertical movement due to deflection within the floorslabs is catered for by slotted holes in the cleats,therefore external cladding weightmust be supported from a suitablestructural member designed to carrythese vertical loads. Where buildings exceed3 storeys in height additional vertical load supportsmay be necessary in accordance with structuralcalculations.

The lower end of the vertical stud sections shouldbe connected to a suitable support member tocarry the vertical weight of the stud section togetherwith attached insulation material, internal finishes,windows, exterior cladding (not masonry) etc. inaccordance with structural calculations.

32 PAGE HADLEY STEEL FRAMING OCT 08 (SSL) 20/10/08 14:49 Page 24

8 9

S Y S T EMOVERVIEW

auditoriumseating support

SYSTEMOVERVIEW

detailing anddesign

Adaptable, lightweight, compact and high strengthconstruction methodology

Considerable reduction in support structure deadload

Small easily handled components are eminentlysuitable for installation in confined spaces orprojects with limited access

Speedy installation hastens project completion

Comprehensive, project specific ‘indicative design’assists in accurate tendering processes

Full structural calculations supplied as an integralpart of the order process

Detailed construction drawing service available tosuit project requirements

Warranted by Professional Indemnity (PI) andProduct Liability insurance

32 PAGE HADLEY STEEL FRAMING OCT 08 (SSL) 20/10/08 14:14 Page 12

10 11

S Y S T EMOVERVIEW

projectsupport

Support from concept tocompletion

When considering light gauge steel framing theHADLEY STEEL FRAMING team are available fromproject conception to completion both willing andable to assist with all design and constructionissues. Working closely with clients and designteams, Hadley’s personnel are able to inform andoffer best practice solutions on the myriad ofstructural engineering requirements necessary tofulfil architectural ideas. Hadley team members areable to attend pre-contract meetings and frequentlycarry out site inspections to ensure work is carriedout to a satisfactory level of competence and inaccordance with design details.

Dependent upon project complexity and installationneeds, detailed drawings can be provided in anumber of different styles to suit workingmethodology. Typical working installation drawingsmay range from minimalist to all encompassing;whatever the requirement, Hadley’s team will providethem quickly and on time.

Market Sectors:

� Commercial

� Industrial

� Apartments

� Health

� Education

� Leisure

� Tourism

� Social housing

� Living accommodation

32 PAGE HADLEY STEEL FRAMING OCT 08 (SSL) 20/10/08 14:14 Page 14

18 19

2812027 ABSOLUTE STEEL FRAMING 08.qxd 18/12/08 15:57 Page 22

18 19

2812027 ABSOLUTE STEEL FRAMING 08.qxd 18/12/08 15:57 Page 22

10 11

S Y S T EMOVERVIEW

projectsupport

Support from concept tocompletion

When considering light gauge steel framing theHADLEY STEEL FRAMING team are available fromproject conception to completion both willing andable to assist with all design and constructionissues. Working closely with clients and designteams, Hadley’s personnel are able to inform andoffer best practice solutions on the myriad ofstructural engineering requirements necessary tofulfil architectural ideas. Hadley team members areable to attend pre-contract meetings and frequentlycarry out site inspections to ensure work is carriedout to a satisfactory level of competence and inaccordance with design details.

Dependent upon project complexity and installationneeds, detailed drawings can be provided in anumber of different styles to suit workingmethodology. Typical working installation drawingsmay range from minimalist to all encompassing;whatever the requirement, Hadley’s team will providethem quickly and on time.

Market Sectors:

� Commercial

� Industrial

� Apartments

� Health

� Education

� Leisure

� Tourism

� Social housing

� Living accommodation

32 PAGE HADLEY STEEL FRAMING OCT 08 (SSL) 20/10/08 14:14 Page 14

12 13

S Y S T EMAPPLICATION

non continuousinfill walling system

HADLEY STEEL FRAMING Non-Continuous InfillSystem creates a steel framed structural stud and tracksystem suitable for use in construction projects whereconventional blockwork might be considered.Our lightweight ‘dry’ system offers savings in materialweight, construction time and labour requirements.

The system is fixed between primary structuremembers and is generally located at the ‘slab edge’ tofacilitate the fixing of insulation and external claddingmaterials which can run continuously outside the mainstructure if desired.HADLEY STEEL FRAMING full height stud sectionsare located and screw fixed via the flanges to shallowfloor track section, itself fixed to the floor slab withfixings and intervals determined by structuralcalculations. The deep track head section is similarlyfixed to the underside of the upper floor slab.Deflection within the primary structure is facilitated bya 25-35mm gap between the stud and head track whichtypically allows a stud/head track bearing of 35-45mm.As the stud is not fixed at the head track interface it isnecessary to restrain the stud sections to resist lateraland torsional movement. Our solution is the use of aSlip-Klip deflection head clip, screw fixed to the headtrack at every stud position.This method permits the use of reduced thickness headtrack and minimises both material and fixing time overconventional blocking methods. If blocking is utilised,it should be fixed between the end pairs of studs andbetween every fourth pair.

A number of Cill, Lintel and Jamb configurations areavailable to suit various design criteria.

Services slots (100mm x 35mm) where specified aretypically located 600mm from the ends of stud sectionsto facilitate the passage of services within the wallcavity. It is recommended that consideration is given toprotecting services where they pass through serviceslots against any sharp edges that may occur.

32 PAGE HADLEY STEEL FRAMING OCT 08 (SSL) 20/10/08 14:27 Page 16

16 17

S Y S T EMAPPLICATION

constructionmethods

CILL TYPES

LINTEL TYPES

JAMB TYPES

32 PAGE HADLEY STEEL FRAMING OCT 08 (SSL) 20/10/08 14:40 Page 20

16 17

S Y S T EMAPPLICATION

constructionmethods

CILL TYPES

LINTEL TYPES

JAMB TYPES

32 PAGE HADLEY STEEL FRAMING OCT 08 (SSL) 20/10/08 14:40 Page 20

12 13

S Y S T EMAPPLICATION

non continuousinfill walling system

HADLEY STEEL FRAMING Non-Continuous InfillSystem creates a steel framed structural stud and tracksystem suitable for use in construction projects whereconventional blockwork might be considered.Our lightweight ‘dry’ system offers savings in materialweight, construction time and labour requirements.

The system is fixed between primary structuremembers and is generally located at the ‘slab edge’ tofacilitate the fixing of insulation and external claddingmaterials which can run continuously outside the mainstructure if desired.HADLEY STEEL FRAMING full height stud sectionsare located and screw fixed via the flanges to shallowfloor track section, itself fixed to the floor slab withfixings and intervals determined by structuralcalculations. The deep track head section is similarlyfixed to the underside of the upper floor slab.Deflection within the primary structure is facilitated bya 25-35mm gap between the stud and head track whichtypically allows a stud/head track bearing of 35-45mm.As the stud is not fixed at the head track interface it isnecessary to restrain the stud sections to resist lateraland torsional movement. Our solution is the use of aSlip-Klip deflection head clip, screw fixed to the headtrack at every stud position.This method permits the use of reduced thickness headtrack and minimises both material and fixing time overconventional blocking methods. If blocking is utilised,it should be fixed between the end pairs of studs andbetween every fourth pair.

A number of Cill, Lintel and Jamb configurations areavailable to suit various design criteria.

Services slots (100mm x 35mm) where specified aretypically located 600mm from the ends of stud sectionsto facilitate the passage of services within the wallcavity. It is recommended that consideration is given toprotecting services where they pass through serviceslots against any sharp edges that may occur.

32 PAGE HADLEY STEEL FRAMING OCT 08 (SSL) 20/10/08 14:27 Page 16

14 15

S Y S T EMAPPLICATION

non continuousinfill walling system

FLOOR TRACK DETAIL

DEFLECTION HEAD TRACK DETAILBLOCKING & BRACING

DEFLECTION HEAD TRACK DETAILSlip-Klip (Subject of UK patent app. No.0421108.2-foreign rights reserved)

LATERAL RESTRAINTBLOCKING & BRACING

Heavy duty track 70mm deep

Standard track70mm deep

Slip-Klip

Stud

Deflection gap25 - 35mm

25mmDeflectionGap

B38Bracing

Where required100 x 35 mm Service Slot,600 mm from ends,to order only70 - 150 seriesstud

Floor Track section (40mm deep) fixed toslab.Fixing quantity/spacings/typeas determined by structural calculations.

Self drilling/self tappingFlush HeadFixing Screws.

150mm

To suit boarddimensionsand designparameters.

B38Bracing

Flush head screws -minimum 5 per side

Stud section blockingcut as a ‘snug fit’ betweenstuds

32 PAGE HADLEY STEEL FRAMING OCT 08 (SSL) 20/10/08 16:57 Page 18