INSTALLATION IN STANDARD & VARIABLE SPEED INDOOR AIR HANDLERS H8HK SERIES ELECTRIC HEATER KIT IMPORTANT ATTENTION INSTALLERS: These instructions are primarily intended to assist qualified individuals experienced in the proper installation of heating and/or air conditioning appliances. Some local codes require licensed installation/service personnel for this type equipment. All installations must be in accordance with these instructions and with all applicable national and local codes and standards. Read these instructions thoroughly before starting the installation. Follow all precautions and warnings contained within these instructions and on the unit. The instructions included with this keater kit are for installations in air handlers only. DO NOT DESTROY. PLEASE READ CAREFULLY & KEEP IN A SAFE PLACE FOR FUTURE REFERENCE. INSTALLATION INSTRUCTIONS

Transcript of H8HK SERIES ELECTRIC HEATER KIT · 2021. 1. 7. · NOTE: For 2-tiered electric heater kits, remove...

Page 1: H8HK SERIES ELECTRIC HEATER KIT · 2021. 1. 7. · NOTE: For 2-tiered electric heater kits, remove two close-off plates. For 3-tiered electric heater kits remove all 3 close-off plates.

INSTALLATION IN STANDARD & VARIABLE SPEED INDOOR AIR HANDLERS

H8HK SERIES ELECTRIC HEATER KIT

IMPORTANTATTENTION INSTALLERS:

These instructions are primarily intended to assist qualified individuals experienced in the proper installation of heating and/or air conditioning appliances. Some local codes require licensed installation/service personnel for this type equipment. All installations must be in accordance with these instructions and with all applicable national and local codes and standards.

Read these instructions thoroughly before starting the installation. Follow all precautions and warnings contained within these instructions and on the unit. The instructions included with this keater kit are for installations in air handlers only.

DO NOT DESTROY. PLEASE READ CAREFULLY & KEEP IN A SAFE PLACE FOR FUTURE REFERENCE.

INSTALLATION INSTRUCTIONS

Page 2: H8HK SERIES ELECTRIC HEATER KIT · 2021. 1. 7. · NOTE: For 2-tiered electric heater kits, remove two close-off plates. For 3-tiered electric heater kits remove all 3 close-off plates.

2

IMPORTANT SAFETY INFORMATIONINSTALLER: Please read all instructions before servicing this equipment. Pay attention to all safety warnings and any other special notes highlighted in the manual. Safety markings are used frequently throughout this manual to designate a degree or level of seriousness and should not be ignored. WARNING indicates a potentially hazardous situation that if not avoided, could result in personal injury or death. CAUTION indicates a potentially hazardous situation that if not avoided, may result in minor or moderate injury or property damage.

WARNING:ELECTRICAL SHOCK, FIRE OR

EXPLOSION HAZARDFailure to follow safety warnings exactly could result in serious injury or property damage.

Improper servicing could result in dangerous operation, serious injury, death or property damage.• Before servicing, disconnect all electrical

power to the unit.• When servicing controls, label all wires prior

to disconnecting. Reconnect wires correctly.• Verify proper operation after servicing.

GENERAL INFORMATIONAbout the heater kitH8HK Series electric heater kit is approved for field installation in B5, B6, MB7, HMG, HMB, & HCG, air handlers. All sizes are available with factory-provided circuit-breakers for short circuit protection and to provide a disconnecting means. Also available are 5, 8, and 10 kw electric heater kits without circuit-breakers. Refer to the National Electric Code (ANSI/NFPA 70) and applicable local codes for over-current protection and disconnect requirements.

NOTES:• The 20, 24, and 29 kw electric heater kits are NOT approved

for installation in A-cabinet air handlers. The 24 & 29 Kw kits are for B6, MB7, HMG, HMB, & HCG C-cabinet air handlers. For all heater kit applications, use Table 1, Table 2, Table 3 (page 6), and Figure 1 (page 5).

• These instructions are written assuming the air handler is in the upflow position (outlet facing up). For horizontal and downflow applications, it is recommended that the electric heater kit be installed prior to installation of the air handler.

• Use caution when handling or installing this component. Personal injury can occur from sharp metal edges present in all sheet metal constructed equipment.

• 460V heater kits are only approved for use in the 460V MB7 (C-cabinet) air handler.

TABLE OF CONTENTSIMPORTANT SAFETY INFORMATION .................... 2

GENERAL INFORMATION ....................................... 2About the heater kit............................................... 2Clearances to Combustibles ................................. 3

Standard Air Handlers ........................................ 3Variable Speed Air Handlers ........................... 3

ELECTRICAL SUPPLY ............................................. 3Power Wiring......................................................... 3

ELEMENT INSTALLATION ....................................... 3Electric Heater Kits with Circuit Breakers ............. 3

5, 8, & 10 kw Electric Heater Kits ....................... 415, 20, 24, & 29 kw Electric Heater Kits ............. 43-Phase 9 & 15 kw electric heater kits ............... 4Line Cover .......................................................... 4

Electric Heater Kits without Circuit Breakers ........ 4Staged Heat .......................................................... 4

MOTOR SPEED SELECTION ................................... 4Standard Air Handlers .......................................... 4

Standard 3 Speed Motors ................................... 4Standard C-Cabinets .......................................... 4

Variable Speed Air Handlers ................................ 4

FIGURES & TABLES ................................................ 5Figure 1. Heater Kit Identification Code .............. 5Figure 2. Sample Installation .............................. 5Figure 3. Installation of Circuit Breakers ............. 5Figure 5. Line Cover Installed ............................. 5Figure 4. Line Cover ........................................... 5Figure 6. Circuit Breaker Bracket with

Terminal Block Installed ....................... 5Table 1. Blower Heating Speed ........................... 6Table 2. HMG Cabinet Sizes ............................... 6Table 3. Electrical Ratings ................................... 6Figure 7. H8HK Heater Kit Installation ................ 6

Wiring Diagrams ................................................... 7Figure 8. Single Phase, 3kW & 5 kw W.D............ 7Figure 9. Single Phase, 8kw & 10 kw W.D. ......... 8Figure 10. Single Phase, 15 kw W.D. .................. 9Figure 11. Single Phase, 20 kw WD ................... 10Figure 12. Single Phase, 25 kw WD ................... 11Figure 13. Single Phase, 30 kw W.D. ................. 12Figure 14. 3-Phase, 9kw & 15kw W.D. ................ 13Figure 15. 3-Phase, 460V W.D. ........................... 14

Page 3: H8HK SERIES ELECTRIC HEATER KIT · 2021. 1. 7. · NOTE: For 2-tiered electric heater kits, remove two close-off plates. For 3-tiered electric heater kits remove all 3 close-off plates.

3

Clearances to CombustiblesStandard Air HandlersAll installations of H8HK electric heater kits in standard air handlers are approved for zero-clearance to combustibles when the minimum electric heat airlfow is set as directed in these instructions.

Variable Speed Air HandlersAll installations of H8HK electric heater kits in variable speed air handlers are approved for zero-clearance to combustibles when the minimum electric heat airflow is set as directed in these instructions.

ELECTRICAL SUPPLY• All electrical connections must be in compliance with all

applicable local codes with the current revision of the National Electric Code (ANSI/NFPA 70). For Canadian installations the electrical connections and grounding shall comply with the current Canadian Electrical Code (CSA C22.1 and/or local codes).

• If the air handler was previously installed without electric heat, the existing supply wiring may not be sufficient to carry the increased load. If installing electric heat in the air handler, the supply wiring can be aluminum or copper. The supplied circuit breakers and terminal blocks are approved for either wire type. Make sure to follow all of the rating information on the circuit breaker or terminal block and that the supply wiring is sized according to the current NEC codes and any other state or local codes. See the rating label or Table 3 (page 6) for minimum circuit ampacities and maximum overcurrent protection.

• All heater kits are supplied from the factory configured for use with one or more supply circuits. 5 & 10 kw heater kits 10 are configured for use with a single supply circuit (Circuit A). 15 & 20 kW heater kits are configured for use with 2 circuits (Circuit A & Circuit B). 24 & 29 kW heater kits are configured for use with 3 circuits (Circuit A, Circuit B, & Circuit C). See Table 3 for additional information. NOTE: If a single supply is desired, accessory kit #913874 is required to convert to single circuit connection.

Power WiringAll wiring must comply with the current revision of the National Electric Code and must be sized for the minimum ampacities as listed on the unit data label or in Table 3. Refer to Figure 8 (page 7), Figure 9 (page 8), Figure 10 (page 9), Figure 11 (page 10), Figure 12 (page 11), Figure 13 (page 12), & Figure 14 (page 13) for proper connections.

If a single circuit adaptor kit is used it may need to be re-configured for some applications. Remove the single circuit adaptor kit cover and verify that the lugs are configured correctly for the application. If the lugs are not configured for the application, reference the instructions included with the kit and modify the configuration. Install the single circuit adaptor kit (if used) in the line side (“on” end) of the circuit breakers. Tighten the lugs securely (45 in-lbs recommended).

Connect the supply wiring to the circuit breaker(s), single circuit adaptor kit, or terminal block. Tighten the lugs securely.

When using multiple supply circuits verify that the supply sized for circuit “A” is connected to the circuit breaker that is connected to the top element assembly.

Install metal circuit breaker line cover on the left side of the circuit breaker to cover the supply wires.

ELEMENT INSTALLATION1. Set the thermostat to the lowest temperature setting.2. Turn off all electrical power to the air handler.3. Remove the upper access door from the air handler.4. Remove the screws securing the upper element close-off

plate from the back of the air handler control box.5. Remove the element close-off plate and set the screws

aside. Do not discard the screws. NOTE: For 2-tiered electric heater kits, remove two close-off plates. For 3-tiered electric heater kits remove all 3 close-off plates. The close off plates should be removed from the bottom up in ascending order.

6. Insert the element assembly into the opening in the air handler control box being careful not to damage the element wire or the ceramic element supports. NOTE: Heating element alignment rods will slide into alignment holes in the back of the air handler element box.

7. Secure the element assembly to the back of the air handler control box with the screws removed in step 4.• For 15, 20, 24, or 29 kw Heater Kits the AC relay bracket

also needs to be installed.a.) Place the AC relay bracket below the bottom element

plate so the back edge is behind the element plate. b.) Line up the slot hole on the bracket with the half hole

on the element plate. See Figure 7 (page 6).

8. Single Stage Board: Connect the W wires from the control board (white), AC relay (white) and the W wire from the thermostat with one of the supplied wire nuts. Connect the C wires from the board (grey), AC relay (grey) and C wire (if supplied) from the thermostat with one wire nut.

Two-Stage Board: Place the W1 wire from the thermostat and the white wire from the AC relay under the W1 screw terminal on the board. Place the C wire from the thermostat (if present) and the grey wire from the AC relay underneath the C terminal on the control board.

9. Connect the 2-Pin Power plug from the element assembly into the unit's 2-Pin power plug. Connect the 7-Pin Harness from the element assembly to the unit's circuit board.

NOTE: A wiring diagram and a rating label are supplied with the electric heater kit. Affix the wiring diagram to the blower housing.

• When installing the electric heater kit into a standard air handler, affix the supplied rating label over the electrical data section of the air handler unit data label located on the lower access door.

• When installing the electric heater kit into a variable speed air handler, the rating label supplied with the kit will NOT be used. Check the appropriate block on the air handler ratings label located on the lower access door.

8. Install the circuit breaker bracket inside of the air handler. Position the tab on the bottom of the bracket into the slot of the control panel box. See Figure 2 (page 5) for proper location of bracket.

9. Slide the bracket forward and align the screw holes with the holes in the bottom of the control panel box. Secure the bracket to the air handler with the supplied screws.

Electric Heater Kits with Circuit BreakersNOTE 1: Circuit breakers supplied with the H8HK electric heater kit are for short-circuit protection of the internal wiring and to serve as a unit disconnect. They DO NOT provide over-current protection of the supply wiring. Over-current protection of the supply wiring must be provided at the

Page 4: H8HK SERIES ELECTRIC HEATER KIT · 2021. 1. 7. · NOTE: For 2-tiered electric heater kits, remove two close-off plates. For 3-tiered electric heater kits remove all 3 close-off plates.

4

distribution panel and sized as shown in Table 3 (page 6) or the unit data label, and in accordance with the NEC and all applicable local codes.

NOTE 2: In some cases, the over-current protection specified in Table 3 (or the unit data label) is less than the 60 amp rating of the circuit breakers used in the H8HK electric heater kit. This difference may occur if the function of the over-current protection required at the distribution panel (field supplied) and the function of the circuit breakers in the H8HK electric heater kit are different.

5, 8, & 10 kw Electric Heater Kits1. Snap the circuit breaker onto the circuit breaker bracket.

The circuit breaker must be positioned with the 1/4" tab terminals to the right as shown in Figure 3 (page 5).

2. Remove the lower circuit breaker knockout from the air handler upper access door.

15, 20, 24, & 29 kw Electric Heater KitsNOTE 1: The heavy red and black supply leads are bundled by circuit with wire ties at the factory. The bundle coming from the top element tier is circuit “A”.

NOTE 2: The element assembly is right-side-up when the limits are on the right side). The bundle coming from the second element tier is circuit “B”. The bundle coming from the bottom element tier is circuit "C".

1. Snap the circuit breaker onto the circuit breaker bracket. The circuit breaker must be positioned with the 1/4" tab terminals to the right as shown in Figure 3 (page 5)

2. Remove all necessary circuit breaker knockouts in the air handler upper access door.

3-Phase 9 & 15 kw electric heater kits1. Snap the 3-pole circuit breaker onto the circuit breaker

bracket. The circuit breaker must be positioned with the 1/4" tab terminals to the right as shown in Figure 3 (page 5).

2. Remove the bottom two circuit breaker knockouts in the air handler upper access door.

Line CoverHeater Kits with circuit breakers are supplied with a line cover shown in Figure 4 (page 5). The line cover is required by code in order to protect installers from the line/supply wiring. The line cover should be installed as shown in Figure 5 (page 5).

Electric Heater Kits without Circuit Breakers1. Attach the supplied power terminal block to the circuit

breaker bracket with the supplied screws as shown in Figure 6 (page 5).

2. Using the 1/4" terminals, connect the red supply wire(s) from the element assembly to one pole of the terminal block and connect the black wires to the other pole.

Staged HeatAll Single-phase heater kits are internally staged using B5, B6, HMG and HMB air handler circuit board logic. B5 air handlers may stage the heater kit with a slow or fast timed option. B6 single stage air handlers will not stage the heater kit. B6 two-stage air handlers may stage the heat Kw turned on with either a low or high heat call. All 3-phase heater kits are not equipped for internal staging. Refer to the installation instructions supplied with the air handler for additional staging information.

MOTOR SPEED SELECTIONStandard Air HandlersThe blower speed is preset at the factory for operation at the same speed for heating and cooling, by using the blower motor jumpering terminal on the blower motor and connecting it to the desired speed with both the red and black wires connected to the jumpering terminal. For optimum system performance and comfort, it may be necessary to change the factory set speed. To change the blower speed:

WARNING:To avoid the risk of electric shock, personal injury, or death, disconnect all electrical power to the unit before performing any maintenance or service. The unit may have more than one electrical power supply.

1. Disconnect all electrical power to the unit and remove the upper door.

2. Remove the black and red wires from the blower motor jumping terminal.

3. Connect the heating speed wire (red) and the cooling speed wire (black) to the desired blower speed marked on the terminal block of the blower motor. If needed, re-use the motor jumping terminal.

IMPORTANT NOTEAfter changing the blower speed setting, make sure to bundle and insulate any unused blower motor leads so that they will not make contact with the air handler cabinet or non-insulated live parts.

Standard 3 Speed MotorsTerminal 4 = Hi speedTerminal 5 = Med speedTerminal 6 = Low speed

Standard C-CabinetsTerminal M1 = Low speedTerminal M2 = Medium Low speedTerminal M3 = Medium speedTerminal M4 = Medium Hi speedTerminal M5 = Hi speed.

High speed operation may be required when using a 20, 24, or 29 kw electric heater kit in a downflow application. Also see Clearances to Combustibles (page 3).

4. Replace the upper door and secure it to the unit.5. Restore power to the unit.

Variable Speed Air HandlersThe minimum electric heat airflow is selected by setting switches on the air handler circuit board. Selecting the minimum electric heat airflow sets the minimum air flow that will be produced whenever electric heater kits are energized. When the electric heater kits are energized along with a heat pump, the airflow may be higher depending on the basic cooling/heat-pump airflow setting. Reference the installation instructions supplied with the air handler for additional airflow information.

Page 5: H8HK SERIES ELECTRIC HEATER KIT · 2021. 1. 7. · NOTE: For 2-tiered electric heater kits, remove two close-off plates. For 3-tiered electric heater kits remove all 3 close-off plates.

5

Figure 5. Line Cover Installed

Figure 2. Sample Installation(shown with access door removed)

2 - Pin Connector

7 - Pin Connector

Circuit BreakerBracket

Figure 4. Line CoverFigure 3. Installation of Circuit Breakers

FIGURES & TABLES

Figure 6. Circuit Breaker Bracket with Terminal Block Installed

Figure 1. Heater Kit Identification Code

H HK 020 - H 1Product Type:

H-Heater

Product Identifier:HK - Heater Kit

Generation:6 - Sixth Series

No. of Breakers

Electric Code:H=240 - 1 - 60Q=208 / 240 - 3 - 60S=480 - 3 - 60

StageSequencer

005 - 5Kw008 - 8Kw009 - 9Kw

010 - 10Kw

015 - 15Kw020 - 20Kw024 / 025 - 25Kw029 / 030 - 30Kw

Primary Capacity:

8 2

Page 6: H8HK SERIES ELECTRIC HEATER KIT · 2021. 1. 7. · NOTE: For 2-tiered electric heater kits, remove two close-off plates. For 3-tiered electric heater kits remove all 3 close-off plates.

6

Table 2. HMG Cabinet Sizes

MODEL CABINET SIZE

H(M,C)G024 AH(M,C)G030 AH(M,C)G036 BH(M,C)G042 BH(M,C)G048 CH(M,C)G060 C

MODELH8HK-

CABINETSIZE

MINIMUM REQUIRED BLOWERHEATING SPEED

A B C UPFLOW HORIZONTAL DOWNFLOW

005H X X X LOW LOW LOW008H X X X LOW LOW LOW010H X X X LOW LOW LOW015H X X X LOW LOW MED020H X X LOW LOW HIGH024H X X MED MED HIGH029H X MED MED N/A009Q X X LOW LOW LOW015Q X X LOW LOW MED009S X 1150 CFM 1150 CFM 1150 CFM015S X 1400 CFM 1400 CFM 1400 CFM

(1) Only on *30 (2.5 Ton) model air handlers

Table 1. Blower Heating Speed

Table 3. Electrical Ratings

MODELNUMBER

H8HK-VOLTAGE KW

STANDARD AIR HANDLER(A & B SIZE)

VARIABLE SPEED & STANDARD AIR HANDLER(C SIZE)

MINIMUM CIRCUITAMPACITY

MAX. OVER-CURRENTCIRCUIT AMPACITY

MINIMUM CIRCUITAMPACITY

MAX. OVER-CURRENTCIRCUIT AMPACITY

CIR

CU

IT A

CIR

CU

IT B

CIR

CU

IT C

SIN

GL

EC

IRC

UIT

CIR

CU

IT A

CIR

CU

IT B

CIR

CU

IT C

SIN

GL

EC

IRC

UIT

CIR

CU

IT A

CIR

CU

IT B

CIR

CU

IT C

SIN

GL

EC

IRC

UIT

CIR

CU

IT A

CIR

CU

IT B

CIR

CU

IT C

SIN

GL

EC

IRC

UIT

005H-XX 240 4.8 - - - 30 - - - 30 - - - 32 - - - 35008H-XX 240 7.5 - - - 45 - - - 45 - - - 47 - - - 50010H-XX 240 9.6 - - - 55 - - - 60 - - - 57 - - - 60015H-XX 240 14.4 50 30 - 80 60 30 - 80 50 32 - 82 60 35 - 90020H-XX 240 19.2 55 50 - 105 60 60 - 110 57 50 - 107 60 60 - 110024H-XX 240 24.0 - - - - - - - - 50 50 32 132 60 60 35 150029H-XX 240 28.8 - - - - - - - - 57 50 50 157 60 60 60 175

005H-XX 208 3.6 - - - 27 - - - 30 - - - 29 - - - 30008H-XX 208 5.6 - - - 39 - - - 40 - - - 42 - - - 45010H-XX 208 7.2 - - - 49 - - - 50 - - - 51 - - - 60015H-XX 208 10.8 44 27 - 70 45 30 - 70 44 29 - 72 45 30 - 80020H-XX 208 14.4 49 44 - 92 50 45 - 100 51 44 - 94 60 45 - 100024H-XX 208 18.0 - - - - - - - - 44 44 29 116 45 45 30 125029H-XX 208 21.6 - - - - - - - - 51 44 44 137 60 45 45 150

009Q-XX 240 9.0 - - - 32 - - - 35 - - - 34 - - - 35015Q-XX 240 14.4 - - - 48 - - - 50 - - - 51 - - - 60009Q-XX 208 6.8 - - - 29 - - - 30 - - - 31 - - - 35015Q-XX 208 10.8 - - - 43 - - - 45 - - - 45 - - - 45

009S-XX 460 - - - - - - - - - - - 19 - - - 20015S-XX 460 - - - - - - - - - - - 28 - - - 30

*Blower motor amps assumed to be highest in each air handler family.

Line up the slot hole on thebracket with the half hole on

the element plate Place the AC relaybracket behind theelement plate.

Figure 7. H8HK Heater Kit Installation

Page 7: H8HK SERIES ELECTRIC HEATER KIT · 2021. 1. 7. · NOTE: For 2-tiered electric heater kits, remove two close-off plates. For 3-tiered electric heater kits remove all 3 close-off plates.

7

Figure 8. Single Phase, 3kW & 5 kw W.D.(Air Handler with Circuit Breaker(s))

21

BLA

CK

12

RE

D

OR

AN

GE

GR

EY

7-P

IN P

LUG

2-P

IN

PO

WE

R P

LUG

LIM

ITE

LEM

EN

TD

C R

ELA

YA

C R

ELA

Y

CO

NN

EC

T T

O C

ON

CO

NT

RO

L B

OA

RD

CO

NN

EC

T T

O W

1 O

N C

ON

TR

OL

BO

AR

D

CIR

CU

ITB

RE

AK

ER

(Circ

uit b

reak

erm

odel

s on

ly)

TE

RM

INA

LB

LOC

K(f

or s

elec

tm

odel

s on

ly)

SU

PP

LY V

OLT

AG

E

BLA

CK

RE

D R

ED

BLA

CK

RE

D

GR

EY

WH

ITE

NO

TE

S:

1. I

f an

y o

f th

e o

rig

inal

wir

e su

pp

lied

wit

h t

his

un

it

m

ust

be

rep

lace

d, i

t m

ust

be

rep

lace

d w

ith

wir

ing

m

ater

ial o

f th

e sa

me

gau

ge

size

an

d t

emp

erat

ure

rat

ing

.2.

Th

e in

stal

lati

on

of

this

hea

ter

kit

may

req

uir

e a

chan

ge

in t

he

blo

wer

sp

eed

tap

co

nn

ecti

on

. See

Inst

alla

tio

n

In

stru

ctio

ns

for

det

ails

.3.

Use

co

pp

er c

on

du

cto

rs w

ith

a m

inim

um

tem

per

atu

re

r

atin

g o

f 60

°C fo

r su

pp

ly c

on

nec

tio

ns.

FIE

LD W

IRIN

G

LEG

EN

D:

LOW

VO

LTA

GE

HIG

H V

OLT

AG

E

3 kW

, 5 k

W, 1

-Ph

ase

Ele

ctri

c H

eate

r K

itH

8HK

005H

-01

(wit

h c

ircu

it b

reak

er)

H8H

K00

5H-1

1 (w

ith

ou

t ci

rcu

it b

reak

er)

7114

33C

(Rep

lace

s 71

1433

B)

06/1

7

WIR

ING

DIA

GR

AM

Wiring Diagrams

Page 8: H8HK SERIES ELECTRIC HEATER KIT · 2021. 1. 7. · NOTE: For 2-tiered electric heater kits, remove two close-off plates. For 3-tiered electric heater kits remove all 3 close-off plates.

8

Figure 9. Single Phase, 8kw & 10 kw W.D.(Air Handler with Circuit Breaker(s))

BLA

CK

12

RE

D

GR

EY

OR

AN

GE

BLU

E

21 3

LIM

ITA

C R

ELA

Y

2-P

IN

PO

WE

R P

LUG

DC

RE

LAY

CIR

CU

ITB

RE

AK

ER

(Circ

uit b

reak

erm

odel

s on

ly)

7-P

IN P

LUG

CO

NN

EC

T T

O C

ON

CO

NT

RO

L B

OA

RD

CO

NN

EC

T T

O W

1 O

N C

ON

TR

OL

BO

AR

D

TE

RM

INA

LB

LOC

K(f

or s

elec

tm

odel

s on

ly) S

UP

PLY

VO

LTA

GE

ELE

ME

NT

BLA

CK

BLA

CK

RE

D

RE

D

RE

D

RE

D

BLA

CK

BLA

CK

GREY

GREY

WHITE

GR

EY

WH

ITE

RE

D

RE

D

NO

TE

S:

1. If

any

of

the

ori

gin

al w

ire

sup

plie

d w

ith

th

is u

nit

mu

st b

e re

pla

ced

, it

mu

st b

e re

pla

ced

wit

h w

irin

g

m

ater

ial o

f th

e sa

me

gau

ge

size

an

d t

emp

erat

ure

rat

ing

.2.

Th

e in

stal

lati

on

of

this

hea

ter

kit

may

req

uir

e a

chan

ge

in t

he

blo

wer

sp

eed

tap

co

nn

ecti

on

. See

Inst

alla

tio

n

In

stru

ctio

ns

for

det

ails

.3.

Use

co

pp

er c

on

du

cto

rs w

ith

a m

inim

um

tem

per

atu

re

ra

tin

g o

f 60

°C fo

r su

pp

ly c

on

nec

tio

ns.

FIE

LD W

IRIN

G

LEG

EN

D:

LOW

VO

LTA

GE

HIG

H V

OLT

AG

E

8kW

, 10k

W, 1

-Sta

ge,

240

VA

C, 1

-Ph

ase

Ele

ctri

c H

eate

r K

it

H8H

K00

8H-0

1 (w

ith

ou

t ci

rcu

it b

reak

er)

H8H

K00

8H-1

1 (w

ith

cir

cuit

bre

aker

)H

8HK

010H

-11

(wit

h c

ircu

it b

reak

er)

H8H

K01

0H-0

1 (w

ith

ou

t ci

rcu

it b

reak

er)

7114

34C

(Rep

lace

s 71

1434

B)

06/1

7

WIR

ING

DIA

GR

AM

Page 9: H8HK SERIES ELECTRIC HEATER KIT · 2021. 1. 7. · NOTE: For 2-tiered electric heater kits, remove two close-off plates. For 3-tiered electric heater kits remove all 3 close-off plates.

9

BLA

CK

12

RE

D

GR

EY

OR

AN

GE

BLU

E

21 3 4Y

ELL

OW

CO

NN

EC

T T

O C

ON

CO

NT

RO

L B

OA

RD

CO

NN

EC

T T

O W

1 O

NC

ON

TR

OL

BO

AR

D

CIR

CU

ITB

RE

AK

ER

(Circ

uit b

reak

erm

odel

s on

ly)

SU

PP

LY V

OLT

AG

ELIM

ITE

LEM

EN

TA

C R

ELA

YD

C R

ELA

Y

2-P

IN

PO

WE

R P

LUG

7-P

IN P

LUG

BLA

CK

BLA

CK

RE

D

RE

D

RE

D

RE

D

GR

EY

WH

ITE

BLA

CK

BLA

CK

RE

D

RE

D

GREY

GREY

WHITE

GREY

GREY

WHITE

BLA

CK

RE

D R

ED

BLA

CK

RE

DN

OT

ES

:1.

If a

ny o

f the

ori

gina

l wir

e su

pplie

d w

ith th

is u

nit m

ust b

e

rep

lace

d, it

mus

t be

repl

aced

with

wir

ing

mat

eria

l of t

he

s

ame

gaug

e si

ze a

nd te

mpe

ra-t

ure

ratin

g.2.

The

inst

alla

tion

of th

is h

eate

r ki

t may

req

uire

a c

hang

e in

the

blo

wer

spe

ed ta

p co

nnec

tion.

See

Inst

alla

tion

In

stru

ctio

ns fo

r de

tails

.3.

Use

cop

per

cond

ucto

rs w

ith a

min

imum

tem

pera

ture

rat

ing

of 6

0°C

for

supp

ly c

onne

ctio

ns.

FIE

LD W

IRIN

G

LEG

EN

D:

LOW

VO

LTA

GE

HIG

H V

OLT

AG

E

15kW

, 240

VA

C, 1

-Ph

ase

Ele

ctri

c H

eate

r K

it

H8H

K01

5H-2

1 (w

ith

cir

cuit

bre

aker

)

7114

35C

(Rep

lace

s 71

1435

B)

06/1

7

WIR

ING

DIA

GR

AM

Figure 10. Single Phase, 15 kw W.D.(Air Handler with Circuit Breaker(s))

Page 10: H8HK SERIES ELECTRIC HEATER KIT · 2021. 1. 7. · NOTE: For 2-tiered electric heater kits, remove two close-off plates. For 3-tiered electric heater kits remove all 3 close-off plates.

10

Figure 11. Single Phase, 20 kw WD(Air Handler with Circuit Breaker(s))

BLA

CK

12

RE

D

5B

RO

WN

GR

EY

OR

AN

GE

BLU

E

YE

LLO

W

21 3 4

ELE

ME

NT

LIM

ITA

C R

ELA

YD

C R

ELA

Y

CIR

CU

ITB

RE

AK

ER

(Circ

uit b

reak

erm

odel

s on

ly)

SU

PP

LY V

OLT

AG

E

CO

NN

EC

T T

O C

ON

CO

NT

RO

L B

OA

RD

CO

NN

EC

T T

O W

1 O

NC

ON

TR

OL

BO

AR

D

2-P

IN

PO

WE

R P

LUG

7-P

IN P

LUG

B

LAC

K

BLA

CK

RE

D

RE

D

RE

D

RE

D

GR

EY

WH

ITE

BLA

CK

BLA

CK

RE

D

RE

D

GREY

GREY

WHITE

GREY

GREY

WHITE

BLA

CK

RE

D R

ED

BLA

CK

RE

D

BLA

CK

RE

D

GREY

RE

D R

ED

GREY

WHITE

BLA

CK

20 k

W, 2

40 V

AC

, 1-P

has

e E

lect

ric

Hea

ter

Kit

H

8HK

020H

-21

(wit

h c

ircu

it b

reak

er)

NO

TE

S

1. I

f an

y o

f th

e o

rig

inal

wir

e su

pp

lied

wit

h t

his

u

nit

mu

st b

e re

pla

ced

, it

mu

st b

e re

pla

ced

w

ith

wir

ing

mat

eria

l of

the

sam

e g

aug

e si

ze

and

tem

per

atu

re r

atin

g.2.

Th

e in

stal

lati

on

of

this

hea

ter

kit

may

req

uir

e a

chan

ge

in t

he

blo

wer

sp

eed

tap

co

nn

ecti

on

. S

ee In

stal

lati

on

Inst

ruct

ion

s fo

r d

etai

ls.

3. U

se c

op

per

co

nd

uct

ors

wit

h a

min

imu

m

tem

per

atu

re r

atin

g o

f 60

°C f

or

sup

ply

co

nn

ecti

on

s.

FIE

LD W

IRIN

G

LEG

EN

D:

LOW

VO

LTA

GE

HIG

H V

OLT

AG

E

7114

36C

(Rep

lace

s 71

1436

B)

06/1

7

WIR

ING

DIA

GR

AM

Page 11: H8HK SERIES ELECTRIC HEATER KIT · 2021. 1. 7. · NOTE: For 2-tiered electric heater kits, remove two close-off plates. For 3-tiered electric heater kits remove all 3 close-off plates.

11

Figure 12. Single Phase, 25 kw WD(Air Handler with Circuit Breaker(s))

BLA

CK

12

RE

D

5B

RO

WN

GR

EY

OR

AN

GE

BLU

E

YE

LLO

W

21 3 4

ELE

ME

NT

LIM

ITA

C R

ELA

YD

C R

ELA

Y

CIR

CU

ITB

RE

AK

ER

(Circ

uit b

reak

erm

odel

s on

ly)

SU

PP

LY V

OLT

AG

E

CO

NN

EC

T T

O C

ON

CO

NT

RO

L B

OA

RD

CO

NN

EC

T T

O W

1 O

NC

ON

TR

OL

BO

AR

D

6W

HIT

E

2-P

IN

PO

WE

R P

LUG

7-P

IN P

LUG

BLA

CK

BLA

CK

RE

D

RE

D

RE

D

RE

D

GR

EY

WH

ITE

BLA

CK

BLA

CK

RE

D R

ED

GREY

GREY

WHITE

GREY

GREY

WHITE

BLA

CK

RE

D R

ED

BLA

CK

RE

D

BLA

CK

RE

D

GREY

RE

D R

ED

GREY

WHITE

BLA

CK

BLA

CK

RE

D R

ED

RE

D

BLA

CK

GREY

WHITE

GREY

FIE

LD W

IRIN

G

LEG

EN

D:

LOW

VO

LTA

GE

HIG

H V

OLT

AG

E

NO

TE

S

1. I

f an

y o

f th

e o

rig

inal

wir

e su

pp

lied

wit

h t

his

u

nit

mu

st b

e re

pla

ced

, it

mu

st b

e re

pla

ced

w

ith

wir

ing

mat

eria

l of

the

sam

e g

aug

e si

ze

and

tem

per

atu

re r

atin

g.2.

Th

e in

stal

lati

on

of

this

hea

ter

kit

may

req

uir

e a

chan

ge

in t

he

blo

wer

sp

eed

tap

co

nn

ecti

on

. S

ee In

stal

lati

on

Inst

ruct

ion

s fo

r d

etai

ls.

3. U

se c

op

per

co

nd

uct

ors

wit

h a

min

imu

m

tem

per

atu

re r

atin

g o

f 60

°C f

or

sup

ply

co

nn

ecti

on

s.

25kW

, 24

0 VA

C,

1-P

has

e E

lect

ric

Hea

ter

Kit

H

8HK

024H

-31

(wit

h c

ircu

it b

reak

er)

7114

37C

(Rep

lace

s 71

1437

B)

06/1

7

WIR

ING

DIA

GR

AM

Page 12: H8HK SERIES ELECTRIC HEATER KIT · 2021. 1. 7. · NOTE: For 2-tiered electric heater kits, remove two close-off plates. For 3-tiered electric heater kits remove all 3 close-off plates.

12

BLA

CK

12

RE

D

5B

RO

WN

GR

EY

OR

AN

GE

BLU

E

YE

LLO

W

21 3 4

ELE

ME

NT

LIM

ITA

C R

ELA

YD

C R

ELA

Y

CIR

CU

ITB

RE

AK

ER

(Circ

uit b

reak

erm

odel

s on

ly)

SU

PP

LY V

OLT

AG

E

CO

NN

EC

T T

O C

ON

CO

NT

RO

L B

OA

RD

CO

NN

EC

T T

O W

1 O

NC

ON

TR

OL

BO

AR

D

6W

HIT

E

2-P

IN

PO

WE

R P

LUG

7-P

IN P

LUG

7V

IOLE

T

BLA

CK

BLA

CK

RE

D

RE

D

RE

D

RE

D

GR

EY

WH

ITE

BLA

CK

BLA

CK

RE

D

RE

D

GREY

GREY

WHITE

GREY

GREY

WHITE

BLA

CK

RE

D R

ED

BLA

CK

RE

DB

LAC

K

RE

D

GREY

RE

D R

ED

GREY

WHITE

BLA

CK

BLA

CK

RE

D R

ED

RE

DB

LAC

K

GREY

WHITE

GREY GREY

GREY

WHITE

RE

DB

LAC

K

BLA

CK

RE

D R

ED

7114

38C

(Rep

lace

s 71

1438

B)

06/1

7

FIE

LD W

IRIN

G

LEG

EN

D:

LOW

VO

LTA

GE

HIG

H V

OLT

AG

E

30kW

, 24

0 VA

C,

1-P

has

e E

lect

ric

Hea

ter

Kit

NO

TE

S

1. I

f an

y o

f th

e o

rig

inal

wir

e su

pp

lied

wit

h t

his

u

nit

mu

st b

e re

pla

ced

, it

mu

st b

e re

pla

ced

w

ith

wir

ing

mat

eria

l of

the

sam

e g

aug

e si

ze

and

tem

per

atu

re r

atin

g.2.

Th

e in

stal

lati

on

of

this

hea

ter

kit

may

req

uir

e a

chan

ge

in t

he

blo

wer

sp

eed

tap

co

nn

ecti

on

. S

ee In

stal

lati

on

Inst

ruct

ion

s fo

r d

etai

ls.

3. U

se c

op

per

co

nd

uct

ors

wit

h a

min

imu

m

tem

per

atu

re r

atin

g o

f 60

°C f

or

sup

ply

co

nn

ecti

on

s.

H8H

K02

9H-3

1 (w

ith

cir

cuit

bre

aker

)

WIR

ING

DIA

GR

AM

Figure 13. Single Phase, 30 kw W.D.(Air Handler with Circuit Breaker(s))

Page 13: H8HK SERIES ELECTRIC HEATER KIT · 2021. 1. 7. · NOTE: For 2-tiered electric heater kits, remove two close-off plates. For 3-tiered electric heater kits remove all 3 close-off plates.

13

7114

39B

(Rep

lace

s 71

1439

A)

06/1

7

FIE

LD W

IRIN

G

LEG

EN

D:

LOW

VO

LTA

GE

HIG

H V

OLT

AG

E

WIR

ING

DIA

GR

AM

H8H

K 3

-Ph

ase

Ele

ctri

c H

eate

r K

it, 2

08/2

40V

NO

TE

S:

1) T

he

blo

wer

mo

tor

spee

d t

ap c

on

nec

tio

n m

ay n

ot

no

t b

e as

sh

ow

n. S

ee t

he

Inst

alla

tio

n In

stru

ctio

ns.

2) D

isco

nn

ect

all p

ow

er b

efo

re s

ervi

cin

g.

3) T

ran

sfo

rmer

may

hav

e a

du

al v

olt

age

pri

mar

y ta

p. M

atch

th

e ta

p p

osi

tio

n w

ith

th

e su

pp

ly v

olt

age

use

d.

4) I

f th

e In

tern

al w

irin

g is

rep

lace

d,u

se o

nly

105

°C c

op

per

wir

e o

f th

e sa

me

gau

ge.

CIR

CU

IT

BR

EA

KE

RS

SU

PP

LYV

OLT

AG

EG

RO

UN

D

LIM

IT

ELEM

ENT

1EL

EMEN

T 1

ELEM

ENT

2EL

EMEN

T 2

ELEM

ENT

3

ELEM

ENT

3

CO

M

NO

RELA

Y

L1

L

1

L2

L

2

L3

L

3

CO

NTA

CTO

R

Fro

m in

do

or

air h

and

ler

circ

uit

bo

ard

13

45

67

2

24V

Fro

m in

do

or

air h

and

ler

tran

sfo

rmer

TRA

NSF

ORM

ER

POW

ER P

LUG

HEA

TER

KIT

PLU

GTo

ind

oo

rai

r han

dle

r ci

rcu

it b

oar

d

WH

ITE

BLA

CK

GREY

RED

YELLOW

BLACK

RE

D

BLA

CK

RE

D

BLA

CK

BLA

CK

YE

LLO

W

BLA

CK

RED

BLACK

OR

AN

GE

BR

OW

N

BLA

CK

RED

YELLOW

RE

D

GR

EY

RE

D

GR

EY

Figure 14. 3-Phase, 9kw & 15kw W.D.

Page 14: H8HK SERIES ELECTRIC HEATER KIT · 2021. 1. 7. · NOTE: For 2-tiered electric heater kits, remove two close-off plates. For 3-tiered electric heater kits remove all 3 close-off plates.

14

3-P

has

e E

lect

ric

Hea

ter

Kit

, 480

V

4. If

th

e in

tern

al w

irin

g is

rep

lace

d, u

se o

nly

105

C c

op

per

wir

e o

f th

e sa

me

gau

ge.

1009

7720

09/1

5

FIE

LD W

IRIN

G

LEG

EN

D:

LOW

VO

LTA

GE

HIG

H V

OLT

AG

E

WIR

ING

DIA

GR

AM

H8H

KN

OT

ES

:1.

Th

e b

low

er m

oto

r sp

eed

set

tin

gs

are

no

t sh

ow

n h

ere.

See

th

e In

stal

lati

on

Inst

ruct

ion

s.2.

Dis

con

nec

t al

l po

wer

bef

ore

ser

vici

ng

.3.

Lin

e vo

ltag

e fr

om

th

e co

nta

cto

r sh

ou

ld b

e co

nn

ecte

d t

o t

he

circ

uit

bre

aker

th

rou

gh

th

e te

rmin

al s

crew

.

CIR

CU

ITB

RE

AK

ER

(Circ

uit B

reak

erin

Air

Han

dler

)

CO

NTA

CTO

R

L1 L2 L3

12

34

56

7

To In

door

Air

Han

dler

Circ

uit B

oard

LIM

IT

480V

From

Indo

or A

ir H

andl

er C

ircui

t Boa

rd

ELE

ME

NT

S

DC

RE

LAY

7 P

IN P

LUG

24V

BR

OW

NB

RO

WN

BLA

CK

YE

LLO

W

RE

D

BLA

CK

BLA

CK

BLA

CK

BLA

CK

BLA

CK

RE

D

RE

DR

ED

GR

EY

GR

EY

GR

EY

OR

AN

GE

RE

D

BLA

CK

WH

ITE

Figure 15. 3-Phase, 460V W.D.

Page 15: H8HK SERIES ELECTRIC HEATER KIT · 2021. 1. 7. · NOTE: For 2-tiered electric heater kits, remove two close-off plates. For 3-tiered electric heater kits remove all 3 close-off plates.

15

Page 16: H8HK SERIES ELECTRIC HEATER KIT · 2021. 1. 7. · NOTE: For 2-tiered electric heater kits, remove two close-off plates. For 3-tiered electric heater kits remove all 3 close-off plates.

INSTALLER: PLEASE LEAVE THESE INSTALLATIONINSTRUCTIONS WITH THE HOMEOWNER

10253230(Replaces 709774D)

Specifications & illustrations subject to change without notice or incurring obligations (12/18).O’Fallon, MO, © Nortek Global HVAC LLC 2018. All Rights Reserved.