H3C S5120-EI Series Ethernet Switches
-
Upload
gena-putni -
Category
Documents
-
view
236 -
download
0
Transcript of H3C S5120-EI Series Ethernet Switches
-
8/12/2019 H3C S5120-EI Series Ethernet Switches
1/31
H3C S5120-EI Series Ethernet SwitchesInstallation Quick Start
Hangzhou H3C Technologies Co., Ltd.
http://www.h3c.com
Document Version:6PW103-20110321
-
8/12/2019 H3C S5120-EI Series Ethernet Switches
2/31
Copyright 2009-2011, Hangzhou H3C Technologies Co., Ltd.
and its licensors
All Rights ReservedNo part of this manual may be reproduced or transmitted in any form
or by any means without prior written consent of Hangzhou H3C
Technologies Co., Ltd.
Trademarks
H3C, , Aolynk, , H3Care, , TOP G, ,
IRF, NetPilot, Neocean, NeoVTL, SecPro, SecPoint, SecEngine,
SecPath, Comware, Secware, Storware, NQA, VVG, V2G, V
nG,
PSPT, XGbus, N-Bus, TiGem, InnoVision and HUASAN are
trademarks of Hangzhou H3C Technologies Co., Ltd.
All other trademarks that may be mentioned in this manual are the
property of their respective owners.
Notice
The information in this document is subject to change without notice.
Every effort has been made in the preparation of this document to
ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute the warranty of
any kind, express or implied.
Environmental Protection
This product has been designed to comply with the requirements on
environmental protection. For the proper storage, use and disposal of
this product, national laws and regulations must be observed.
-
8/12/2019 H3C S5120-EI Series Ethernet Switches
3/31
Preface
This Installation Quick Startprovides steps for basic installation for
the S5120-EI series switches. Further information, such as optionalinstallation and configuration procedures are available in the
Installation Manual.
This preface includes:
Audience
Conventions
Obtaining Documentation Technical Support
Documentation Feedback
Audience
This documentation is intended for:
Network planners
Field technical support and servicing engineers
Network administrators working with the S5120-EI series
Conventions
This section describes the conventions used in this documentation
set.
Convention Description
Means reader be extremely careful. Improperoperation may cause bodily injury.
Means reader be careful. Improper operation maycause data loss or damage to equipment.
Means a complementary description.
-
8/12/2019 H3C S5120-EI Series Ethernet Switches
4/31
Obtaining Documentation
You can access the most up-to-date H3C product documentation on
the World Wide Web at http://www.h3c.com.
Click the links on the top navigation bar to obtain different categories
of product documentation:
[Technical Support & Documents > Technical Documents] Provides
hardware installation, software upgrading, and software feature
configuration and maintenance documentation.
[Products & Solutions] Provides information about products and
technologies, as well as solutions.
[Technical Support & Documents > Software Download] Provides
the documentation released with the software version.
Technical Support
http://www.h3c.com
Documentation Feedback
You can e-mail your comments about product documentation to
We appreciate your comments.
http://www.h3c.com/http://www.h3c.com/portal/Technical_Support___Documents/Technical_Documents/http://www.h3c.com/portal/Products___Solutions/http://www.h3c.com/portal/Technical_Support___Documents/Software_Download/http://www.h3c.com/portal/Technical_Support___Documents/Software_Download/http://www.h3c.com/portal/Products___Solutions/http://www.h3c.com/portal/Technical_Support___Documents/Technical_Documents/http://www.h3c.com/ -
8/12/2019 H3C S5120-EI Series Ethernet Switches
5/31
i
Table of Contents
1 Prepare for installation ......................................................................... 1-1Safety recommendations ................................................................... 1-1Examine the installation site............................................................... 1-1Installation accessories...................................................................... 1-2Installation tools.................................................................................. 1-2
2 Install the switch ................................................................................... 2-1
Inspect the switch............................................................................... 2-1Mounting the switch to a rack............................................................. 2-1Mounting the switch on a workbench................................................. 2-3Connecting the grounding cable ........................................................ 2-4Connecting the power cable............................................................... 2-5Installing the interface card ................................................................ 2-6
3 Appendix Compliance and safety in formation ..................................3-1Regulatory Compliance Information................................................... 3-1
Regulatory compliance standards .............................................. 3-1European Directives compliance................................................ 3-2USA regulatory compliance........................................................ 3-2Canada regulatory compliance................................................... 3-3Japan regulatory compliance...................................................... 3-3CISPR 22 compliance ................................................................ 3-4CLASS A............................................................... 3-4
Safety Information Sicherheits informationen......................3-4Overview berblick ............................................................ 3-4Electricity Safety Elektrische Sicherheit....................3-11Laser Laser ................................................................ 3-16
-
8/12/2019 H3C S5120-EI Series Ethernet Switches
6/31
1-1
1 Prepare for installationSafety recommendations
To avoid possible bodily injury and equipment damage, read the
following safety recommendations before installing an H3C S5120-EI
series. Note that the recommendations do not cover every possible
hazardous condition.
Turn off all power and remove all the power cables before
opening the chassis. Before cleaning, unplug the power plug first
and do not clean with a wet cloth or liquid.
Keep the chassis clean and dust-free and away from water or a
damp environment; do not place on an unstable case or desk.
Ensure proper ventilation of the equipment room and keep the
ventilation vents of the switch free of obstruction.
Make sure that the operating voltage is the same as labeled onthe switch.
When replacing interface modules, wear ESD-preventive gloves
to avoid damaging the cards.
For more compliance and safety information, see AppendixCompliance and safety information.
Examine the installation site
The H3C S5120-EI series can only be used indoors. Make sure that
the floor can support the weight of the cabinet and the switch chassis.
-
8/12/2019 H3C S5120-EI Series Ethernet Switches
7/31
1-2
To ensure the normal operation of the switch, ensure that the
following elements meet requirements described in Preparing for
installation in the S5120-EI Installation Manual: temperature/
humidity, cleanness, electromagnetic susceptibility and laser safety.
Installation accessories
Figure 1-1 Installation accessories
Installation tools
The following tools are required for installation; they are not shipped
with the S5120-EI series. Please prepare them by yourself.
Figure 1-2 Installation tools
-
8/12/2019 H3C S5120-EI Series Ethernet Switches
8/31
2-1
2 Install the switchThis guide provides basic installation steps. See the S5120-EI
Installation Manual for comprehensive procedures for installing the
switch.
Inspect the switch
Follow these steps before installing an S5120-EI switch:
Make sure that you have read Prepare for installation carefullyand that the installation site meets all the requirements.
Using the packing list that was supplied with your switch, inspect
the switch to be sure that you have all the items listed in the
packing list, and verify that the switch was not damaged during
shipment. If anything is damaged or missing, contact your H3C
customer representative.
Mounting the switch to a rack
Table 2-1 Installation methods
The depth of a switch
Installation method
300 mm(11.81 in.)
420 mm(16.54 in.)
Using only front mounting brackets
Using front and rear mounting brackets
Before installation, wear an ESD-preventive wrist strap, and makesure that the wrist strap has a good skin contact and is well grounded.
-
8/12/2019 H3C S5120-EI Series Ethernet Switches
9/31
2-2
Figure 2-1 Using only front mounting brackets
Figure 2-2 Using front and rear mounting brackets
-
8/12/2019 H3C S5120-EI Series Ethernet Switches
10/31
2-3
There are three positions to mount a load-bearing screw on both
sides of a switch. You should select a proper position according to theactual requirements. The rear mounting brackets tightly contactedwith the load-bearing screws can support the switch.
Mounting the switch on a workbench
In many cases, standard 19-inch racks are not available. Therefore,switches are often placed on clean workbenches. To place your
switch on a workbench, you simply need to:
Make sure that the workbench is clean, flat, and sturdy.
Make sure that the environment is well ventilated and allows 10
cm (3.94 in.) of space around the chassis for heat dissipation.
Do not place heavy objects on your switch.
The vertical distance between two switches must be at least 1.5
cm (0.59 in).
Figure 2-3 Mounting the switch on a workbench
2
Stick the rubber pads to theappropriate positions onthe switch bottom
1
-
8/12/2019 H3C S5120-EI Series Ethernet Switches
11/31
2-4
Connecting the grounding cable
Figure 2-4 Connecting the grounding cable
Use the PGND cable provided with the switch to connect the
grounding strip in the equipment room. Otherwise, the grounding
effect may not be ensured, which easily causes damage to the
switch.
If no grounding strip is available, see S5120-EI Installation
Manual for detailed grounding methods.
-
8/12/2019 H3C S5120-EI Series Ethernet Switches
12/31
2-5
Connecting the power cable
Before connecting the power cable, connect the grounding cable
and make sure that the switch is correctly grounded.
Connect the power cable to the switch first and then to the power
supply system to avoid bodily injury.
You can use only the RPS power supply recommended by H3C
(optional RPS power supply and power cable) for RPS input.
Figure 2-5 Connect the AC power cable
Install the bail latch
12 3
Connect the power cable tothe receptacle
Secure the bail
latch over thepower cable
-
8/12/2019 H3C S5120-EI Series Ethernet Switches
13/31
2-6
Figure 2-6 Connect the DC (RPS) power cable
Installing the interface card
Figure 2-7 Installing the interface card
Remove a blank panel
1
2
Installing the interfacecard
-
8/12/2019 H3C S5120-EI Series Ethernet Switches
14/31
2-7
Do not touch the electronic components on an interface card to
avoid damaging the interface card.
After removing an interface card, install a blank panel to the
empty slot to prevent dust from entering the switch.
If there is a DO NOT REMOVE label on the rear panel, the
switch does not support interface cards. Do not remove the blank
panel that has the label on it.
-
8/12/2019 H3C S5120-EI Series Ethernet Switches
15/31
3-1
3 Appendix Compliance and safetyinformationRegulatory Compliance Information
Regulatory compl iance standards
Table 3-1 Regulatory compliance standards
Discipline Standards
EMC
FCC Part 15 (CFR 47) CLASS AICES-003 CLASS A
VCCI-3 CLASS A
VCCI-4 CLASS A
CISPR 22 CLASS A
EN 55022 CLASS A
AS/NZS CISPR22 CLASS A
CISPR 24
EN 55024
EN 61000-3-2
EN 61000-3-3
EN 61000-6-1
ETSI EN 300 386
GB 9254
YD/T993
Safety
UL 60950-1
CAN/CSA C22.2 No 60950-1
IEC 60950-1
EN 60950-1/A11
AS/NZS 60950-1
EN 60825-1
EN 60825-2
FDA 21 CFR Subchapter J
GB 4943
-
8/12/2019 H3C S5120-EI Series Ethernet Switches
16/31
3-2
European Directives compliance
LVD/EMC Directive
S5120-EI SERIES products comply with the European Low Voltage
Directive 2006/95/EC and EMC Directive 2004/108/EC.
A copy of the signed Declaration of Conformity can be downloaded
from:http://www.h3c.com/portal/Technical_Documents .
WEEE Directive2002/96/EC
The products this manual refers to are covered by the Waste
Electrical & Electronic Equipment (WEEE) Directive and must be
disposed of in a responsible manner.
USA regulatory compliance
FCC Part 15S5120-EI SERIES comply with Part 15 of the FCC Rules. Operation
is subject to the following two conditions:
This device may not cause harmful interference.
This device must accept any interference received, including
interference that may cause undesired operation.
If the customer modifies the equipment without the authorization ofH3C, which directly or indirectly contribute to the equipment
incompliance with FCC requirements for Class A digital devices, H3C
http://www.h3c.com/portal/Technical_Documentshttp://www.h3c.com/portal/Technical_Documents -
8/12/2019 H3C S5120-EI Series Ethernet Switches
17/31
3-3
is not liable for such interference problem and the expenses incurred
therefrom shall be covered by the customers.
This equipment has been tested and found to comply with the limitsfor a Class A digital device, pursuant to Part 15 of the FCC Rules.These limits are designed to provide reasonable protection againstharmful interference when the equipment is operated in a commercialenvironment. This equipment generates, uses, and can radiate radiofrequency energy and, if not installed and used in accordance with theinstruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area islikely to cause harmful interference in which case the user will berequired to correct the interference at his own expense.
FDA
S5120-EI SERIES Conform to the applicable requirements of 21 CFR
Subchapter J
Canada regulatory compliance
ICES-003
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numrique de la classe A est conforme la norme
NMB-003 du Canada.
Japan regulatory compliance
VCCI
S5120-EI SERIES comply with the requirements of VCCI Class A
Information Technology Equipment (ITE).
Warning: If this equipment is used in a domestic environment, radio
disturbance may arise. When such trouble occurs, the user may berequired to take corrective actions.
-
8/12/2019 H3C S5120-EI Series Ethernet Switches
18/31
3-4
CISPR 22 compliance
S5120-EI SERIES comply with the requirements of CISPR 22 for
Class A Information Technology Equipment (ITE).
Warning:If this equipment is used in a domestic environment, radiodisturbance may arise. When such trouble occurs, the user may be
required to take corrective actions.
CLASS A
A
Safety Information Sicherheits informationenOverview berblick
This section introduces part of the safety precautions that should be
followed during the installation and maintenance of the equipment.
And for the safety statements and warnings, there followed the
translations of both German and Chinese to comply with the national
requirements.
Dieser Abschnitt macht Sie mit den Sicherheitsvorschriften vertraut,
die Sie bei der Installation und Instandhaltung der Ausrstung
beachten mssen.
-
8/12/2019 H3C S5120-EI Series Ethernet Switches
19/31
3-5
Before any operation is performed, please read the operation
instructions and precautions carefully to minimize the possibilityof accidents. The Note, Caution, Warning and Dangeritems in
other manuals do not cover all safety precautions that should be
followed. They are only the supplements to the safety
precautions for operations as a whole. Therefore, the personnel
in charge of the installation and maintenance of the products are
required to understand these basics of safety operation.
In performing various operations, please follow the local safety
regulations. The safety precautions introduced in the product
manuals are supplementary and subject to the local safety
regulations.
When various operations are executed on the products, the
precautions and special safety instructions provided with the
products must be followed to the full.
The personnel in charge of the installation and maintenance of
the products must be trained as professionals to master the
proper operating methods and all safety precautions. Only the
trained and qualified personnel can perform operations such as
equipment installation and maintenance.
-
8/12/2019 H3C S5120-EI Series Ethernet Switches
20/31
3-6
Lesen Sie bitte alle Arbeitsanweisungen und
Sicherheitvorschriften sorgfltig durch, bevor Sie mit demArbeiten beginnen. Nur durch Beachtung dieser Hinweise lsst
sich das Unfallrisiko minimieren. Die in anderen Handbchern
aufgefhrten Symbole Anmerkung, Achtung, Warnung und
Gefahr beinhalten nicht alle zu beachtenden
Sicherheitvorschriften. Sie dienen lediglich der Ergnzung.
Deshalb muss sich das fr die Installation und Instandhaltung
der Ausrstung verantwortliche Personal mit allen
Sicherheitshinweise vertraut machen.
Bei der Durchfhrung der verschiedenen Arbeitsschritte mssen
auerdem die rtlichen Sicherheitsvorschriften beachtet werden.
Die in den Handbchern der einzelnen Produkte aufgefhrten
Sicherheitshinweise sind Ergnzungen und unterliegen den
nationalen Sicherheitsvorschriften.
Whrend der Arbeit mit den Produkten sind deshalb
grundstzlich alle Sicherheitsvorschriften und spezifischen
Sicherheitshinweise genau zu beachten.
Das fr die Installation und Instandhaltung der Produkte
verantwortliche Pesonal muss geschult werden, um alle
Sicherheitsvorschriften zu kennen und die richtigenArbeitsmethoden anwenden zu knnen. Nur geschultes und
qualifiziertes Personal kann die Installation und Instandhaltung in
korrekter Weise durchfhren.
-
8/12/2019 H3C S5120-EI Series Ethernet Switches
21/31
3-7
Conventions Used Symbole Erluterung The symbols in this manual are shown in the following table. They are
used to remind the reader of the safety precautions during equipment
installation and maintenance.
Die Symbole in diesem Handbuch verwendeten sind in der folgenden
Tabelle dargestellt. Diese Symbole sollen das Personal whrend der
Installation und Instandhaltung der Ausrstung an die Wichtigkeit der
im Handbuch aufgefhrten Sicherheitsvorschriften erinnern.
-
8/12/2019 H3C S5120-EI Series Ethernet Switches
22/31
3-8
Table 3-2 Safety symbol and description
Sicherheitssymbole und Beschreibung
SafetySymbol
Symbole
Description
ErluterungGeneric alarm symbol: To suggest a general safetyconcern
Alarm: Hinweis auf ein generelles Sicherheitsproblem
ESD protection symbol: To suggestelectrostatic-sensitive equipment.
ESD-Schutz: Hinweis auf Beschdigung infolgeelektrostatischer Entladung
Electric shock symbol: To suggest a danger of highvoltage
Elektrischer Schlag: Hinweis auf Gefhrdung durchHochspannung
Laser symbol: To suggest a strong laser beam
Laser: Hinweis auf starken Laser
General Requirements Al lgemeine AnforderungenIn order to reduce the technically unavoidable residual risk to a
minimum, it is imperative to follow the rules below:Um das technisch bedingte Restrisiko auf ein Minimum zu begrenzen,
ist es unbedingt erforderlich, die folgenden Regeln zu beachten:
Read all the instructions before operation.
Lesen Sie alle Anweisungen sorgfltig durch, bevor Sie mit dem
Arbeiten beginnen.
-
8/12/2019 H3C S5120-EI Series Ethernet Switches
23/31
3-9
When installing the unit, always make the ground connection first
and disconnect it last.
Beachten Sie, dass bei der Installation des Systems stets zuerst
die Erdverbindung angebracht wird und das die Erdverbindungstets als letztes getrennt wird.
Do not block ventilation openings while the system is on, and
keep at least 5 cm distance from ventilation openings and walls
or other things which may block the openings.
Sorgen Sie dafr, dass die ffnungen der Ventilation zu keinem
Zeitpunkt verschlossen, verstopft oder anderweitig blockiert sind.
Zwischen den Ventilationsffnungen und Wnden bzw. anderen
Gegenstnden muss stets ein Abstand von mindestens 5cm
bestehen.
5cm
Never defeat the ground conductor or operate the equipment in
the absence of a suitably installed ground conductor. Contact the
appropriate electrical inspection.
Betreiben Sie die Ausrstung niemals ohne Erdung. Trennen Sie
das System nicht von der Erdung. Kontaktieren Sie die
entsprechende elektrische Kontrolle.
The unit/system must be connected to the protection ground
before operation permanently. And the cross-section of
protective earthing conductor shall be at least 0.75mm2
Das System muss vor der stndigen Inbetriebnahme geerdet
werden. Der Querschnitt der Erdverbindung sollte mindestens
0.75mm2betragen.
-
8/12/2019 H3C S5120-EI Series Ethernet Switches
24/31
3-10
/
0.75mm2
For AC supplied model: The device applies to TN power
systems. Mit Wechselstrom betriebenes Modell: Das Gert arbeitet mit
einem Phase-Nullleiter-System.
AC TN
For DC supplied model: The device applies to DC power source
that complies with the Safety Extra-Low Voltage (SELV)
requirements in IEC 60950 based safety standards.
Mit Gleichstrom betriebenes Modell: Das Gert arbeitet mit
Gleichstrom, wobei die Anforderungen der Norm (IEC60950) fr
Schutzkleinspannung eingehalten werden mssen.
DC IEC60950
(SELV)
For AC supplied model: The plug-socket combination must be
accessible at all times because it serves as the main
disconnecting device.
Mit Wechselstrom betriebenes Modell: Der Netzstecker muss
jederzeit leicht zugnglich sein. Denn sie dient als wichtigstes
Trennvorrichtung.
AC
Because the device has several power supplies, disconnect all ofthem to switch off the device.
Da das Gert mehrere Energiequellen hat, ist es notwendig stets
alle Verbindungen zu unterbrechen, um den energiefreien
Zustand zu erreichen.
To prevent laser radiation from hurting your eyes, never stare
into the open optical port.
-
8/12/2019 H3C S5120-EI Series Ethernet Switches
25/31
3-11
Nehmen Sie das Gert nicht in Betrieb, solange das optische
Fenster nicht geschlossen ist. Der Laserstrahl kann zu
Augenverletzungen fhren.
H3C S5120-EI may be powered by a DC RPS, if the Customer
need the DC power source, the DC RPS power source must be
supplied by H3C company.
Einige H3C S5120-EI Switches knnen durch eine DC RPS
Energiequelle angetrieben werden, aber die DC RPS
Energiequelle mu von H3C geliefert werden.
S5120-EI DC RPS
DC RPS H3C
DC RPS
Electricity Safety Elektrische Sicherheit High Voltage Hochspannung
High voltage power supply offers electric power for equipmentoperation. Direct contact or indirect contact (via damp objects) withhigh voltage and AC mains supply may result in fatal danger.
Die Hochspannungsleitungen stellen fr die Arbeit der Ausrstungerforderliche Energie zur Verfgung. Direkter oder indirekter Kontakt(z. B. durch feuchte Gegenstnde) mit Hochspannung und
Wechselstromversorgung kann zu tdlichen Unfllen fhren.
-
8/12/2019 H3C S5120-EI Series Ethernet Switches
26/31
3-12
AC
During the installation of AC power supply facility, the local safety
regulations must be followed. The personnel who install the AC
facility must be qualified for high voltage and AC operations.
Bei der Installation der Wechselstromversorgung sind die
rtlichen Sicherheitsbestimmungen zu beachten. Das Personal
muss besonders qualifiziert sein fr das Arbeiten mit
Hochspannung und Wechselstrom.
AC
Conducting articles, such as watch, hand chain, bracelet and ring
are prohibited during the operation.
Es ist nicht erlaubt whrend dieser Arbeiten leitende
Gegenstnde wie Uhren, Armbnder, Armreifen und Ringe am
Krper zu tragen.
When water is found in the rack, or the rack is damp, pleaseimmediately switch off the power supply.
Sollte sich Wasser im Baugruppentrger befinden oder der
Baugruppentrger feucht sein, ist die Energiezufuhr sofort zu
unterbrechen und das System abzuschalten.
When operation is performed in a damp environment, make surethat water is kept off the equipment.
-
8/12/2019 H3C S5120-EI Series Ethernet Switches
27/31
3-13
Muss in einem feuchten Umgebung gearbeitet werden, ist
sicherzustellen, dass kein Wasser in die Ausrstung dringen
kann.
Non-standard and improper high voltage operations may result in fireand electric shock. Therefore, AC cable bridging and wiring through acertain area must follow the local rules and regulations. Thepersonnel who perform high voltage operations should be qualified
for high voltage and AC operations.
Die Nichtbeachtung der Sicherheitsvorschriften bei der Arbeit mitHochspannung kann zu Feuer und elektrischem Schlag fhren.
Deshalb muss die Verlegung von Leitungen und Verbindungen denrtlichen Anforderungen und Sicherheitsvorschriften entsprechen.
Arbeiten mit Hochspannung drfen nur von qualifiziertemFachpersonal durchgefhrt werden.
AC
-
8/12/2019 H3C S5120-EI Series Ethernet Switches
28/31
3-14
Power Cable Zuleitung
Installation and removal of live power cable is prohibited strictly.Transient contact between the core of power cable and conductormay generate electric arc or spark or electric arc, which may lead tofire or eye injury.
Das Entfernen und Anbringen von Zuleitungen ist strengstensverboten. Kurzschlsse zwischen innerem und uerem Leiterknnen Lichtbgen oder Funkenflug verursachen, was zu Feuer odereiner Augenverletzung fhren kann.
Before the power cable is installed or removed, the power switchmust be turned off.
Das System muss stets abgeschaltet werden, bevor die
Zuleitung angebracht oder entfernt wird.
Before the power cable is connected, it must be confirmed that
the power cable and label comply with the requirements of the
actual installation.
-
8/12/2019 H3C S5120-EI Series Ethernet Switches
29/31
-
8/12/2019 H3C S5120-EI Series Ethernet Switches
30/31
3-16
Arbeiten mit Hochspannung und Wechselstrom oder Arbeiten auf
Stahltrmen und masten whrend eines Gewitters sind verboten. Umdie Ausrstung vor Beschdigung durch Blitzschlag zu schtzen, isteine ordnungsgeme Erdung erforderlich.
AC
Laser LaserThe laser hazard level of this equipment is Class 1.
Die von diesem Laser ausgehende Gefahr entspricht der Kategorie 1.
1
When performing installation and maintenance operations of opticalfibers, you should not stand close to, or look into the optical fiberoutlet directly with unaided eyes.
Whrend der Installation und Instandhaltung der optischen Fasern
drfen Sie nicht zu nahe am Ausgang der optischen Fasern stehenund nicht ohne Augenschutz in die optischen Fasern sehen.
-
8/12/2019 H3C S5120-EI Series Ethernet Switches
31/31