productsH2S Air Filtration Unit
APPLICATION
Our H2S air filtration system provides clean filtered fresh air, free from H2S contaminates in an overpressure refuge. Three levels of filtration (coalescer, dust, and composite filtration) is applied to incoming air before being supplied to the refuge. The overpressure refuge removes the need for occupants to wear gas masks and protective clothing during H2S release. Two modes of operation allows clean fresh air to be supplied during normal operation, and filtered fresh air during H2S release.The control system constantly compares inside and outside pressures, and should the refuge pressurization fail, provide a visual and/or audible warning.Our H2S air filtration unit is designed for external installation to the refuge with a supply duct to the refuge’s interior. The H2S air filtration control unit is designed to be installed internally within the refuge covering the air duct to diffuse air entering the refuge. When the H2S air filtration unit is operational the unit is designed as a fail-safe system, i.e. should the unit sustain damage or an air seal leak, then clean air will leak out of the unit rather than contaminated air being drawn in.
INTRODUCTION
During the extraction of oil and gas from the various depths within the Earth’s crust larger or smaller quantities of hydrogen sulphide may also be released. As the result of leaky joints on any of the pipes on a platform, or during cleaning of the oil or gas, this poisonous gas can escape into the surrounding areas and thus becomes a serious threat for the crew. A concentration of 500 ppm (0.05 vol.%) produces unconsciousness with just a few breaths. 1000 ppm (0.1 vol.%) are fatal within a few minutes and a concentration of 5000 ppm (0.5 vol.%) proves fatal within seconds. In order to protect the personnel from this treacherous and deadly peril, the drilling industry searched over a period of time for suitable protection systems. Our H2S air filtration unit is one of them.
KEY FEATURES
• Very high removal efficiency• Engineered approach to elimination of leaks• Media contained in user refillable cells• Pre- and after- filtration• Wide range of operational temperatures [-32°C to +45°C]• Easy service and maintenance access;• Compact and lightweight;• Completely closed system;• Doors equipped with end switches• Custom designed capacities
H2S-VDBS
Technical Data H2S-VDBS - 50Hz / 60Hz
Ambient H2S concentration 600ppm
Refuge H2S concentration 10ppm (60min)
Air quantity (custom designed) m3/h
Pst (custom designed) Pa
Execution SS316L, ATEX Ex II 2G T4
Primary filter G4
Secondary filter F7
Tertiary filter Activated Carbon + Alumina
Power supply fan 3x380V-50Hz / 3x440V-60HZ
Rated power (custom designed) kW
Power supply heater 3x380V-50Hz / 3x440V-60Hz
Capacity (custom designed) kW
Weight (excl. heater) TBD kg
Control panel (separate delivery)
Safe Area
Alternatives available on request.Owing to continuous product development Heinen Hopman reserves the right to introduce alterations without prior notice.
Model A B C1 C2 C3 D E F G H I
VDBS-F-(1/2/3)-1000 457 457 767 1067 1367 457 1372 1320 1320 1220 1220
VDBS-F-(1/2/3)-1500 457 457 767 1067 1367 550 1200 1320 1980 1220 1830
VDBS-F-(1/2/3)-2500 457 457 767 1067 1367 550 1200 1980 1980 1830 1830
VDBS-F-(1/2/3)-4500 457 457 767 1067 1367 550 1200 2235 2235 2135 2135
VDBS-F-(1/2/3)-5500 457 457 767 1067 1367 550 1200 2235 2845 2135 2745
VDBS-F-(1/2/3)-7000 457 457 767 1067 1367 550 1200 2845 2845 2745 2745
VDBS-F-(1/2/3)-10000 457 457 767 1067 1367 550 1200 3150 3150 3050 3050
www.heinenhopman.com
Heinen & Hopman encourages a more
sustainable world. By providing eco-friendly solutions and serviceswe offer our clients
the option of reducing energy consumption
and thus co2 emissions. Visit
greenmanifest.info for more information.
BrazilT: +55 213 587 4241/4244E: [email protected]
France - La CiotatT: +33 4 4204 8685E: [email protected]
France - AntibesT: +33 6 3090 7786 E: [email protected]
GermanyT:+49 4073 1680E: [email protected]
GermanyT:+49 471 9869 300E: [email protected]
IndiaT: +91 336 499 1293E: [email protected]
ItalyT: +39 018 745 7970E: [email protected]
The Netherlands (HQ)T: +31 33 299 2500E: [email protected]
The Netherlands (Rotterdam)T: +31 78 890 8050E: [email protected]
NorwayT: +47 6919 0900E: [email protected]
Peoples Republic of ChinaT: +86 213 253 2896E: [email protected]
Peoples Republic of ChinaT: +86 510 8528 1763E: [email protected]
PolandT: +48 914 331 800E: [email protected]
RomaniaT: +40 236 448 222E: [email protected]
RussiaT: +7 (4012) 308 801E: [email protected]
SingaporeT: +65 6897 7879E: [email protected]
South KoreaT: +82 704 901 0000E: [email protected]
SpainT: +34 932 259 668E: [email protected]
SwedenT: +46 3121 7500E: [email protected]
TurkeyT: +90 216 493 8118E: [email protected]
UAE (Abu Dhabi) T:+971 2550 4147E: [email protected]
UAE (Dubai)T: +971 4263 5453E: [email protected]
USA - Fort Lauderdale, FloridaT: +1 954 463 0110E: [email protected]
USA - Houma, Louisiana T: +1 985 876 7982E: [email protected]