1
Glass Enclosed Conference Room Kitchen / break area open work stations Glass Enclosed Office Glass Enclosed Office open work stations restrooms restrooms reception

Transcript of H NORTH SOUTH STAIR BATH 2 STAIR SOUTH STAIR BEDROOM 2€¦ · fire rated semi-recessed fire...

Page 1: H NORTH SOUTH STAIR BATH 2 STAIR SOUTH STAIR BEDROOM 2€¦ · fire rated semi-recessed fire extinguisher cabinet 20. storefront windows above- see interior elevations. 21. dropped

Glass Enclosed Conference Room

B

23

45

67

8

51 2"

12

'-1"

6"

4'-8

1 4"

2'-1

"1

2'-1

2'-2

"

21

'-7"±

7'-8

1 2"

10

'-4"

3'-10"

R6'-0"

R7

'-6"

6"

4'-11"±

51

'-4"

4'-4

"

21

'-4"

25

'-8"

25

'-8"

3'-2

3 8"

6'-1

"7

'-9"

5'-2

"1

3'-3

1 2"±

3'-6"± 18'-10"

10

'-10

"

1'-0"

3'-8

"3

"

8"

3'-3

"

3'-9"

3'-1

"2

'-10

"

134"

2'-1

1"

6"

5'-7"

7'-4"

2'-1"

6"

4'-4

"6

"

5'-10"

12'-0"±

1'-234"

1'-0

3 8"

8'-7" 13'-7" ±

7'-10"

4'-1138"

10'-138"

22'-6"FIELD VERIFY

1'-3

11

"

6'-6"

25

'-13 8"

6'-1

15 8"

6"8'-21

2"± 3'-412"

1'-1

1"

6'-5

1 2"

4'-1

2'-5

1 4"

3'-0

"

1134"

3'-634"3'-21

2"1'-712"

6"

6"

8'-3"

112"

3'-6"±

2'-1" 5'-4" 1'-834"

2'-10"

3'-1

"

2'-1018"

834"

11'-514"

7'-312" 2'-53

4"2

'-0"

2'-4

"

R10'-4"

2'-4"

4'-0

1 8" 7

'-0"

6"4

'-1"

2'-1

3 4"

4'-7

"

1'-878" 41

2"

5'-5

1 4"

2'-8

1 8"

1'-1138"

5'-614"

8"

7'-0

"

20'-5"±

1'-0"

3'-1"±

32BE

DROO

M 2

C|A

|A|A

|

2B

01

15

UNIT

2A

C

11FO

YER

B|A|

A|A|

33FL

EX R

OOM

C|A

|A|A

|

21LI

VING

A|A|

A|A|

b

22KI

TCHE

N

A|A|

A|A|

b

31

MAST

ERBE

DROO

M

C|A

|A|A

|b

14RA

ISED

HAL

L

C|A

|A|A

|

51LA

UNDR

Y

B|B|

A|A|

52ME

CH

B|C

|A|A

|

203

CORR

IDOR

A|A|

A|A|

41

MSTR

BATH

B|B|

A|A|

a,b

13

ENTR

YHA

LL

B|A|

A|A|

BALC

ON

Y

UNIT

2B

20

12

02

2B

02

2B

03

2B

04

42BA

TH 2

B|B|

A|A|

b

12MA

IN H

ALL

A|A|

A|A|

B

B

E

11

"

2'-6

3 8"

314"

1'-012"

27 8"

1'-634"

X3

1

514"

X3

4X

35

X4

1

X4

5

X4

2

X4

6X

32

X1

3

X2

1

X2

2

X5

2

X5

1

X3

3

X3

6

X3

7

X1

1

X1

2

43PO

WDE

R

B|B|

A|A|

X4

3

E

EEE

8'-8

"

1'-4"

3'-0

"

4"

4"

1'-2

1 4"

7'-8"

112"

X4

4

UP

DN

UPD

N

D WDW

WH

FUR

N

REF

DW

DW

OV

EN

A1 A501

E1 A300

15

1514

14

1414

14

18

1

1

27 27

45

4

3

6

6

79

b-

a-

8

10U

PU

P

11

11

12

1212

ELEV

ATO

R

002

SOUT

HST

AIR

C|C

|B|-|

b00

1

NORT

HST

AIR

C|C

|B|-|

b

12

1212

17

16

2A

01

2A

02

SEE

UN

IT 2

A F

OR

TY

PIC

AL

DIM

ENS

ION

SS

EE U

NIT

2B

FO

R T

YP

ICA

L K

EYN

OTE

S,

WA

LL T

AG

S, U

NIT

DO

OR

TA

GS

,IN

TER

IOR

ELE

VA

TIO

NS

AN

D D

ETA

ILR

EFEE

NC

ES.

A3 A501

F

F

B19

20

21

8'-8

"

4'-4

"

2222

A9 A350

23

EXIS

TIN

G M

AS

ON

RY

BEA

RIN

G W

ALL

SH

AR

ED W

ITH

AD

JAC

ENT

BU

ILD

ING

SEE

CO

DE

REV

IEW

AT

SH

EET

G0

00

5'-512"

6"

SEE

F1

/A

10

3 F

OR

REF

LEC

TED

CEI

LIN

G P

LAN

16

25

24

24

E EF

F

28F

F28

14 12

C

2 2

E

29

B

A6 A300

A9 A300

A1 A300

A3 A300

4'-3

1 4"

3'-6

"

3030

3'-4

"

26

26

3

31

11

'-11

", 1

3 T

REA

DS

V.I.

F.3

'-8"

4'-5

"

W.I.

C.

W.I.

C.

CO

AT

LIN

EN

CO

AT

CO

AT

LIN

EN

W.I.

C.

CLO

SET

PA

NTR

Y

3'-6"6"

4"

4"

E7 aE7 a

C4 c

C4 c

f

C4a e

db

G8

b

G8

b

E1b

a

A8b da

c

A1c ab

d

G8a

G8

c

TYP

FLR

/C

LGA

SS

EMB

LYP

ER E

4/

A4

01

TYP

FLR

/C

LGA

SS

EMB

LYP

ER E

4/

A4

01

002

SOUT

HST

AIR

001

NORT

HST

AIR

ALT

ERA

TIO

NS

& IM

PR

OV

EMEN

TSfo

r:

23

W. C

OU

RT

STR

EET

CIN

CIN

NA

TI, O

HIO

45

20

2( C

entr

al B

usin

ess

Dis

tric

t )

ISS

UED

FO

R P

ERM

IT0

4.1

2.1

6

04

.12

.20

16

01

5-0

20

20

16

NEW

REP

UB

LIC

LTD

.

Draw

ing T

itle

c

Chec

ked

Draw

n

Docu

ment

No.

Proje

ct No

.

Date

Date

No.

Revis

ions/S

ubmi

ssion

s

1211

109

87

65

43

2

ABCDEFGH

1

1211

109

87

65

43

21

I

Desig

n Pro

fessio

nal

THIS DOCUMENT IS THE PRODUCT AND EXCLUSIVE PROPERTY OF NEW REPUBLIC LIMITED NEITHER THE DOCUMENT NOR THE INFORMATION IT CONTAINS MAY BE COPIED OR USED FOR OTHER THAN THE SPECIFIC PROJECT FOR WHICH IT WAS PREPARED WITHOUT THE EXPLICIT CONSENT OF NEW REPUBLIC LIMITEDPLOTTED:Wednesday, April 13, 2016 11:21:21 PM

arch

itect

ure

pla

nnin

g

u

rban

ism

1349

9

KALB

LIM

ICH

AEL

GR

AHAM

GR

AHAM

MIC

HAE

L KA

LBLI

LIC

ENSE

#13

499

EXPI

RAT

ION

DAT

E 12

/31/

17

A1

02

A1

SEC

ON

D F

LOO

R P

LAN

3/

16

"=1

'-0"

NEW

WO

RK

SEC

ON

D F

LOO

R P

LAN

F10

GEN

ERA

L N

OTE

S

ROOM

NUM

BER

FLOO

R - 1

ST L

ETTE

RA

- HAR

DWOO

DB

- CER

AMIC

TILE

C - C

ARPE

T

B ASE

- 2N

D LE

TTER

A - W

OOD

B - C

ERAM

IC T

ILEC-

RES

ILIEN

T

WAL

L - 3

RD L

ETTE

RA

- GW

B, LA

TEX

PAIN

TB

- EXP

OSED

CMU

, SEE

A1/A

102

CEIL

ING

- 4TH

LET

TER

A - G

WB,

LATE

X PA

INT

B - A

COUS

TIC

CEILI

NG S

YSTE

M

FLOO

RBA

SEW

ALL

NOTE

S - T

RAIL

ING

LWR

CASE

LET

TERS

a - C

ERAM

IC T

ILE S

HOW

ER/ T

UB S

URRO

UND

b - T

REAT

EXP

OSED

MAS

ONRY

WAL

LS A

S NO

TED

100

ROOM

NAM

E

F|B|

W|C

|n,n

,n

room

fini

sh le

gend

key

tag

lege

nd

REF

ER T

O W

ALL

TA

GS

AN

D C

OV

ER S

HEE

T FO

R P

AR

TITI

ON

TY

PES

inte

rior

par

titio

n le

gend

PART

ITIO

N TY

PERE

: SHE

ET 40

1DO

OR T

AG R

EF D

OOR

DATA

ON

SHEE

T A6

01

DRAW

ING

KEY

NOTE

SEXIS

TING

MAS

ONRY

WAL

L- 2

HR F

IRE

RATE

D

NEW

MET

AL S

TUD

PART

ITIO

N.PA

RTIT

IONS

ARE

TYP

E 'A

' UNL

ESS

TAGG

EDOT

HERW

ISE.

NEW

CMU

WAL

L. R

EFER

ENCE

PAR

TITI

ONSC

HEDU

LE F

OR A

PPLIE

D RA

TING

S

#

##

-##

NEW

FIR

E RA

TED

STUD

PAR

TITI

ONSE

E W

ALL T

AG F

OR F

IRE

RATI

NG

INTE

RIOR

ELE

VATI

ONAT

SHE

ET A

701

ab

cd

DWG

#EL

EVAT

ION

NOTE

SCE

ILING

GENE

RAL F

INIS

H NO

TES:

1.CO

ORDI

NATE

FIN

ISHE

S W

ITH

DEVE

LOPE

R SP

ECS

AND

BUYE

RSE

LECT

IONS

.2.

PROV

IDE

FLOO

R MA

TERI

AL T

RANS

ITIO

N S

TRIP

AT

DOOR

WAY

S AS

REQU

IRED

UNL

ESS

NOTE

D OT

HERW

ISE.

3.CL

OSET

S, P

ANTR

IES

AND

W.I.C

. SHA

LL R

ECEI

VE T

HE S

AME

FINI

SHES

AS

THE

ADJA

CENT

ROO

M.4.

CEME

NTIO

US B

ACKE

R BO

ARD

SHAL

L BE

INST

ALLE

D BE

LOW

/ BEH

IND

ALL

CERA

MIC

TILE

AT

FLOO

RS A

ND W

ALLS

.

NEW

TYP

E 'A

' MET

AL S

TUD

PART

ITIO

N.W

ITH

3-1/2

" UNF

ACED

SOU

ND B

ATTS

a

1.

INFI

LL E

XIS

TIN

G O

PEN

ING

IN F

LOO

R (A

PP

RO

XIM

ATE

LO

CA

TIO

N).

REF

ER T

O S

TRU

CTU

RA

L D

WG

S

2.

EXIS

TIN

G W

IND

OW

OP

ENIN

G E

NLA

RG

ED F

OR

DO

OR

. REP

AIR

FLO

OR

. SEE

A9

/A

35

0.

3.

SEE

FG

/A

50

1 F

OR

DET

AIL

OF

TOP

OF

CO

LUM

N A

T D

RO

PP

EDC

EILI

NG

.

4.

EXIS

TIN

G S

TEEL

CO

LUM

N P

AIN

TED

W/

INTU

MES

CEN

T P

AIN

T FO

R1

HO

UR

FIR

E R

ATI

NG

. SEE

E1

/A

40

1

5.

EXIS

TIN

G B

EAM

AB

OV

E, P

AIN

TED

. SEE

G1

/A

40

1.

6.

SH

OW

ER:

S

HO

WER

FLO

OR

- PR

OV

IDE

WA

TER

PR

OO

F M

EMB

RA

NE,

MU

DP

AN

AN

D C

ERA

MIC

TIL

E FL

OO

R S

LOP

ED T

O D

RA

IN.

C

ERA

MIC

TIL

E S

UR

RO

UN

D O

VER

CEM

ENT

BA

CK

ER B

D.

TE

MP

ERED

GLA

SS

SH

OW

ER E

NC

LOS

UR

E P

ER D

EVEL

OP

ERS

PEC

.

7.

BU

YER

PR

OV

IDED

WA

SH

ER/

DR

YER

. SEE

DET

AIL

A6

/A

50

1 F

OR

REQ

UIR

EMEN

TS F

OR

DR

YER

EX

HA

US

T M

ATE

RIA

LS A

ND

LO

CA

TIO

N.

8.

GA

S C

OO

K T

OP

W/

EX

HA

US

T H

OO

D (4

00

CFM

MA

X).

RO

UTE

EXH

AU

ST

INTO

RA

TED

SH

AFT

PER

MEC

H D

WG

S.

9.

WA

SH

BA

SIN

, SEE

PLU

MB

ING

.

10

.(3

) 6"

RIS

ERS

(NO

HA

ND

RA

IL R

EQU

IRED

PER

OB

C 1

00

9.1

2)

SEE

D9

/A

50

1

11

.8

'-0"

PA

RTI

AL

HEI

GH

T C

LOS

ET W

ALL

. SEE

D6

/A

50

1

12

.EX

ISTI

NG

BR

ICK

WA

LL. C

LEA

N

13

.EN

TRY

CA

NO

PY

BEL

OW

. SEE

A7

/A

34

0.

14

.C

LOS

ET S

HEL

VIN

G/

HA

NG

RO

D(S

) P

ER D

EVEL

OP

ER S

PEC

S.

15

.C

LOS

ET S

HEL

VIN

G P

ER D

EVEL

OP

ER S

PEC

S.

16

.FL

OO

R M

ATE

RIA

L TR

AN

SIT

ION

STR

IP.

17

.C

LEA

N A

ND

TU

CK

PO

INT

EXIS

TIN

G M

AS

ON

RY

WA

LL.

18

.W

IND

OW

WEL

L D

RA

IN A

ND

OV

ERFL

OW

, SEE

PLU

MB

ING

DW

GS

.

19

.FI

RE

RA

TED

SEM

I-REC

ESS

ED F

IRE

EXTI

NG

UIS

HER

CA

BIN

ET

20

.S

TOR

EFR

ON

T W

IND

OW

S A

BO

VE-

SEE

INTE

RIO

R E

LEV

ATI

ON

S.

21

.D

RO

PP

ED S

OFF

IT A

BO

VE

DO

OR

AT

9'-0

" A

FF.

22

.S

TAN

D P

IPE

- SEE

FIR

E P

RO

TEC

TIO

N D

WG

S.

23

.3

0"

X 3

6"

RO

OF

AC

CES

S H

ATC

H IN

TO W

IND

OW

WEL

L.

24

.R

AIS

ED F

LOO

R A

T FL

EX R

OO

M, R

AIS

ED H

ALL

, LA

UN

DR

Y A

ND

MEC

HA

NIC

AL.

SEE

F7

/A

10

3 A

ND

D9

/A

50

1.

25

.P

RO

VID

E FU

LL D

EPTH

PA

TCH

AS

REQ

UIR

ED A

T M

AS

ON

RY

WA

LLJO

INT.

26

.R

ECES

SED

MED

ICIN

E C

AB

INET

. CO

OR

DIN

ATE

FR

AM

ING

.

27

.TH

RES

HO

LD.

28

.B

UR

NIS

HED

CM

U S

TAIR

/ E

LEV

ATO

R S

HA

FT- S

EE F

1/

A1

02

29

.S

OU

TH S

TAIR

IS O

PP

HA

ND

OF

NO

RTH

STA

IR.

30

.V

ERIF

Y D

IMEN

SIO

N A

ND

CO

OR

DIN

ATE

SEQ

UEN

CIN

G W

ITH

WIT

H E

LEV

ATO

R M

AN

UFA

CTU

RER

.

31

.W

ALL

CA

BIN

ETS

AB

OV

E R

EFR

IGER

ATO

R A

ND

OV

EN S

HA

LL B

EFL

US

H W

ITH

OV

EN C

AB

INET

. FR

AM

E O

UT

WA

LL A

S R

EQU

IRED

.S

EE IN

TER

IOR

ELE

VA

TIO

N.

A.

REF

EREN

CE

SP

ECIF

ICA

TIO

N F

OR

AD

DIT

ION

AL

INFO

RM

ATI

ON

.

B.

BU

ILD

ING

SH

ALL

BE

SP

RIN

KLE

RED

PER

NFP

A-1

3.

C.

DIM

ENS

ION

S A

RE

TO F

AC

E O

F S

TUD

OR

FA

CE

OF

MA

SO

NR

Y U

NLE

SS

NO

TED

OTH

ERW

ISE.

D.

ALL

INTE

RIO

R U

NIT

PA

RTI

TIO

NS

SH

ALL

BE

TYP

E A

UN

LES

S N

OTE

D O

THER

WIS

E.

E.A

LL IN

TER

IOR

PA

RTI

TIO

NS

SH

ALL

BE

3-5

/8

" M

ETA

L S

TUD

S U

NLE

SS

NO

TED

OTH

ERW

ISE.

F.AL

L IN

TER

IOR

PA

RTI

TIO

NS

SH

ALL

BE

FULL

HEI

GH

T TO

MA

TCH

EX

ISTI

NG

UN

LES

SN

OTE

D O

THER

WIS

E.

C.

CEI

LIN

GS

TO

BE

FULL

HEI

GH

T U

NLE

SS

NO

TED

OTH

ERW

ISE.

REF

ER T

O R

EFLE

CTE

DC

EILI

NG

PLA

NS

FO

R D

RO

PP

ED C

EILI

NG

HEI

GH

TS A

ND

LO

CA

TIO

NS

.

D.

ALL

DO

OR

JA

MB

S T

O B

E 4

" FR

OM

PER

PEN

DIC

ULA

R W

ALL

UN

LES

S N

OTE

DO

THER

WIS

E

E.C

ON

TRA

CTO

R S

HA

LL V

ERIF

Y E

XIS

TIN

G C

ON

DIT

ION

S A

ND

DIM

ENS

ION

S IN

TH

EFI

ELD

. V

ERIF

Y A

LL N

EW F

RA

MIN

G D

IMEN

SIO

NS

IN F

IELD

PR

IOR

TO

INS

TALL

ATI

ON

.N

OTI

FY A

RC

HIT

ECT

OF

AN

Y D

ISC

REP

AN

CIE

S P

RIO

R T

O B

EGIN

NIN

G W

OR

K.

F.IN

STA

LL IN

-WA

LL 2

x B

LOC

KIN

G A

T A

LL F

IXED

CA

BIN

ETR

Y L

OC

ATI

ON

S A

S W

ELL

AS

BA

THR

OO

M A

CC

ESS

OR

Y L

OC

ATI

ON

S.

G.

PR

OV

IDE

ALL

REQ

UIR

ED T

HR

OU

GH

-PEN

ETR

ATI

ON

AN

D F

IRE

STO

P S

YS

TEM

S F

OR

CO

DE

CO

MP

LIA

NT

CO

MP

LETI

ON

OF

THE

WO

RK

.

H.

FRA

MIN

G A

ND

IN-W

ALL

PLU

MB

ING

PR

OV

ISIO

NS

SH

ALL

BE

CO

OR

DIN

ATE

D IN

TH

EFI

ELD

PR

IOR

TO

TH

E IN

STA

LLA

TIO

N O

F R

OU

GH

-IN.

I.C

OO

RD

INA

TE P

LUM

BIN

G L

AY

OU

TS T

O E

NS

UR

E TH

AT

ALL

WA

TER

, WA

STE

, AN

DV

ENT

PIP

ING

IS C

ON

CEA

LED

WIT

HIN

NEW

OR

EX

ISTI

NG

WO

RK

.

J.C

OO

RD

INA

TE L

OC

ATI

ON

S O

F A

LL E

XTE

RIO

R E

NV

ELO

PE

PEN

ETR

ATI

ON

S P

RIO

R T

OC

OM

MEN

CEM

ENT

OF

THE

WO

RK

, IN

CLU

DIN

G B

UT

NO

T LI

MIT

ED T

O R

OO

F V

ENTS

,IN

TAK

ES, D

RY

ER V

ENTS

, ETC

.

K.

ALL

DU

CTS

FO

R B

ATH

AN

D D

RY

ER E

XH

AU

ST

AN

D F

RES

H A

IR IN

TAK

E TO

BE

MA

X4

" Ø

DIA

MET

ER E

XH

AU

ST

AN

D 2

6 G

A S

TEEL

. R

AN

GE

HO

OD

EX

HA

US

T D

UC

TSS

HA

LL B

E 2

6 G

A S

TEEL

AN

D L

OC

ATE

D W

ITH

IN A

FIR

E R

ATE

D S

HA

FT P

ER T

HE

DW

GS

.

L.S

MO

KE

DET

ECTO

RS

SH

ALL

BE

INS

TALL

ED IN

EA

CH

SLE

EPIN

G R

OO

M, O

UTS

IDE

OF

EAC

H S

LEEP

ING

AR

EA IN

TH

E IM

MED

IATE

VIC

INIT

Y O

F O

F TH

E B

EDR

OO

MS

. 11

0V

OLT

WIT

H B

ATT

ERY

BA

CK

UP

. TH

E S

MO

KE

ALA

RM

S S

HA

LL B

E H

AR

D-W

IRED

&IN

TER

CO

NN

ECTE

D. S

EE E

LEC

TRIC

DR

AW

ING

S.

M.

A C

AR

BO

N M

ON

OX

IDE

DET

ECTO

R/

ALA

RM

SH

ALL

BE

LOC

ATE

D O

UTS

IDE

OF

EAC

HS

LEEP

ING

AR

EA IN

TH

E IM

MED

IATE

VIC

INIT

Y O

F O

F TH

E B

EDR

OO

MS

.

F6K

EY N

OTE

S

3'-4

"

F1P

AR

TIA

L P

LAN

3/

16

"=1

'-0"

STA

IR/

ELE

VA

TOR

SH

AFT

- CM

U S

CH

EDU

LE

CM

U S

CH

EDU

LE

A1

- C

OLO

R A

(DA

RK

), B

UR

NIS

HED

A2

- C

OLO

R A

(DA

RK

), N

ON

-BU

RN

ISH

EDB

1 -

CO

LOR

A (L

IGH

T), B

UR

NIS

HED

B2

- C

OLO

R A

(LIG

HT)

, NO

N-B

UR

NIS

HED

C

- S

TAN

DA

RD

CM

U

a

a

BA

SEM

ENT:

TYP

E C

1st

- 4

th:

TYP

E A

1/

B1

PER

INT

ELEV

RO

OF:

TYP

E A

2/

B2

PER

INT

ELEV

TOP

2 C

OU

RS

ES- A

2

BA

SEM

ENT:

TYP

E C

1st

- 4

th:

TYP

E B

1R

OO

F:TY

PE

B2

BEL

OW

CA

NO

PY

TYP

E A

2 A

BO

VE

CA

NO

PY

BASEMENT:TYPE C1st - ROOF:TYPE B2

BASEMENT:TYPE C1st - ROOF:TYPE B2

BASEMENT:TYPE C1st FLOOR:TYPE A12nd-ROOF:TYPE A2

RO

OF

(NO

T S

HO

WN

): A

2

BASEMENT:TYPE C1st FLOOR:TYPE A12nd-ROOF:TYPE A2

GEN

ERA

L N

OTE

S:

1.

WH

ERE

CM

U T

YP

ES A

1 A

ND

A2

AR

E U

SED

, TH

E B

UR

NIS

HED

SID

E S

HA

LL F

AC

EO

UTS

IDE

OF

THE

SH

AFT

.2

.A

T S

TAIR

CO

RR

IDO

R W

ALL

US

E TY

PE

A2

AT

FLO

OR

FR

AM

ING

WH

ERE

ENTI

REL

YC

ON

CEA

LED

FR

OM

CO

RR

IDO

R.

3.

AT

ELEV

ATO

R S

HA

FT T

YP

E C

IN L

IEU

OF

B1

MA

Y B

E U

SED

WH

ERE

ENTI

RE

CO

UR

SE

ISEN

TIR

ELY

CO

NC

EALE

D .

4.

AT

RO

OF

PA

TTER

N W

ALL

, US

E TY

PE

A2

WH

ERE

CM

U IS

CO

NC

EALE

D IN

ATT

IC A

ND

BEL

OW

TH

E FI

N F

LR O

F TH

E R

OO

F D

ECK

.

BA

SEM

ENT:

TYP

E C

1st

- 4

th:

TYP

E A

1/

B1

PER

INT

ELEV

RO

OF:

TYP

E A

2/

B2

PER

INT

ELEV

TOP

2 C

OU

RS

ES- A

2

B

2 3 4 5 6 7 8

512"

12'-1"6"

4'-814"2'-1"12'-1"±

2'-2"

21'-7"± 7'-812"

10'-4"

3'-1

0"R

6'-0

"R7'-6"

6"

4'-1

1"±

51'-4"

4'-4"

21'-4"

25'-8" 25'-8"

3'-238"6'-1"7'-9"5'-2"13'-31

2"±

3'-6

"±1

8'-1

0"

10'-10"

1'-0

"

3'-8"3"

8"

3'-3"

3'-9

"

3'-1"2'-10"

13 4"

2'-11"

6"

5'-7

"

7'-4

"

2'-1

"

6"

4'-4"6"

5'-1

0"

12

'-0"±

1'-2

3 4"

1'-038"

8'-7

"1

3'-7

" ±

7'-1

0"

4'-1

13 8"

10

'-13 8"

22

'-6"

FIEL

D V

ERIF

Y

1'-3"±

11"

6'-6

"

25'-138"

6'-1158"

6"

8'-2

1 2"±

3'-4

1 2"

1'-11"

6'-512"

4'-1"±

2'-514"

3'-0"

11

3 4" 3

'-63 4"

3'-2

1 2"

1'-7

1 2"

6"

6"

8'-3

"

11 2"

3'-6

2'-1

"5

'-4"

1'-8

3 4"

2'-1

0"

3'-1"

2'-1

01 8"

83 4"

11

'-51 4"

7'-3

1 2"

2'-5

3 4"

2'-0" 2'-4"

R1

0'-4

"

2'-4"

4'-018"

7'-0"

6"

4'-1"

2'-134"

4'-7"

1'-8

7 8"

41 2"

5'-514"2'-81

8"

1'-1

13 8"5

'-61 4"

8"

7'-0"

20

'-5"±

1'-0

"

3'-1

32BEDROOM 2

C|A|A|A|

2B01

15

UNIT 2A

C

11FOYER

B|A|A|A|

33FLEX ROOM

C|A|A|A|

21LIVING

A|A|A|A|b

22KITCHEN

A|A|A|A|b

31

MASTERBEDROOM

C|A|A|A|b

14RAISED HALL

C|A|A|A|

51LAUNDRY

B|B|A|A|

52MECH

B|C|A|A|

203CORRIDOR

A|A|A|A|

41

MSTRBATH

B|B|A|A|a,b

13

ENTRYHALL

B|A|A|A|

BALCONY

UNIT 2B

201 202

2B02

2B03

2B04

42BATH 2

B|B|A|A|b

12MAIN HALL

A|A|A|A|

B

B

E

11"

2'-638"

31 4"

1'-0

1 2"

278"

1'-6

3 4"

X31

51 4"

X34 X35

X41

X45

X42

X46X32

X13

X21

X22

X52

X51

X33

X36

X37

X11

X12

43POWDER

B|B|A|A|X43

E

E

E

E

8'-8"

1'-4

" 3'-0"

4"

4"

1'-214"

7'-8

"

11 2"

X44

UP

DN

UP

DN

DWD

W

WH

FURN

REF

DW

DW

OVEN

A1A501

E1A300

15

1514

14

1414

14

18

1

1

27

27

4 54

3

6

6

7 9

b-a

-

8

10UPUP

11

11

12

1212

ELEVATOR

002

SOUTHSTAIR

C|C|B|-|b001

NORTHSTAIR

C|C|B|-|b

12

121217

16

2A01

2A02

SEE UNIT 2A FOR TYPICAL DIMENSIONSSEE UNIT 2B FOR TYPICAL KEYNOTES,WALL TAGS, UNIT DOOR TAGS,INTERIOR ELEVATIONS AND DETAILREFEENCES.

A3A501

F

F

B 19

20

21

8'-8"

4'-4"

2222

A9A350

23

EXISTING MASONRY BEARING WALL SHARED WITH ADJACENT BUILDINGSEE CODE REVIEW AT SHEET G000

5'-5

1 2"

6"

SEE F1/A103 FOR REFLECTEDCEILING PLAN

16

25

24

24

E

EF F

28 F F 28

14

12

C

2

2

E

29

B

A6A300

A9A300

A1A300

A3A300

4'-314" 3'-6"

3030

3'-4"

26

26

3

31

11'-11", 13 TREADS V.I.F. 3'-8"4'-5"

W.I.C. W.I.C.

COAT

LINEN

COAT

COAT LINEN

W.I.C. CLOSET

PANTRY

3'-6

"6

"

4"4"

E7a

E7a

C4c

C4c

f

C4a

edb

G8 b

G8 b

E1 ba

A8b

dac

A1c

abd

G8a

G8 c

TYP FLR/CLGASSEMBLYPER E4/A401

TYP FLR/CLGASSEMBLYPER E4/A401

002

SOUTHSTAIR

001

NORTHSTAIR

ALTERATIONS& IMPROVEMENTS

for:

23 W. COURT STREETCINCINNATI, OHIO 45202

( Central Business District )

ISSUED FOR PERMIT 04.12.16

04.12.2016

015-020

2016 NEW REPUBLIC LTD.

Drawing Title

c

Checked

Drawn

Document No.

Project No.

Date

DateNo. Revisions/Submissions

12111098765432

AB

CD

EF

GH

1

121110987654321

I

Design Professional

THIS

DO

CU

MEN

T IS

TH

E PR

OD

UC

T AN

D E

XCLU

SIVE

PR

OPE

RTY

OF

NEW

REP

UBL

IC L

IMIT

ED N

EITH

ER T

HE

DO

CU

MEN

T N

OR

TH

E IN

FOR

MAT

ION

IT C

ON

TAIN

S M

AY B

E C

OPI

ED O

R U

SED

FO

R O

THER

TH

AN T

HE

SPEC

IFIC

PR

OJE

CT

FOR

WH

ICH

IT W

AS P

REP

ARED

WIT

HO

UT

THE

EXPL

ICIT

CO

NSE

NT

OF

NEW

REP

UBL

IC L

IMIT

EDPL

OTT

ED:W

edne

sday

, Apr

il 13

, 201

6 11

:21:

21 P

M

architecture planning urbanism

13499

KALBLIMICHAEL

GRAHAM

GRAHAM MICHAEL KALBLILICENSE #13499

EXPIRATION DATE 12/31/17

A102A1 SECOND FLOOR PLAN3/16"=1'-0" NEW WORK

SECOND FLOOR PLAN

F10 GENERAL NOTES

ROOM NUMBER

FLOOR - 1ST LETTERA - HARDWOODB - CERAMIC TILEC - CARPET

BASE - 2ND LETTERA - WOODB - CERAMIC TILEC- RESILIENT

WALL - 3RD LETTERA - GWB, LATEX PAINTB - EXPOSED CMU, SEE A1/A102

CEILING - 4TH LETTERA - GWB, LATEX PAINTB - ACOUSTIC CEILING SYSTEM

FLOORBASEWALL

NOTES - TRAILING LWR CASE LETTERSa - CERAMIC TILE SHOWER/ TUB SURROUNDb - TREAT EXPOSED MASONRY WALLS AS NOTED

100ROOM NAME

F|B|W|C|n,n,n

room finish legend

key tag legend

REFER TO WALL TAGS AND COVER SHEET FOR PARTITION TYPES

interior partition legend

PARTITION TYPERE: SHEET 401DOOR TAG REF DOORDATA ON SHEET A601

DRAWING KEY NOTES

EXISTING MASONRY WALL- 2 HR FIRE RATED

NEW METAL STUD PARTITION.PARTITIONS ARE TYPE 'A' UNLESS TAGGEDOTHERWISE.

NEW CMU WALL. REFERENCE PARTITIONSCHEDULE FOR APPLIED RATINGS

#

##-#

#

NEW FIRE RATED STUD PARTITIONSEE WALL TAG FOR FIRE RATING

INTERIOR ELEVATIONAT SHEET A701

abc

dDWG #ELEVATION

NOTESCEILING

GENERAL FINISH NOTES:1. COORDINATE FINISHES WITH DEVELOPER SPECS AND BUYER

SELECTIONS.2. PROVIDE FLOOR MATERIAL TRANSITION STRIP AT DOORWAYS AS

REQUIRED UNLESS NOTED OTHERWISE.3. CLOSETS, PANTRIES AND W.I.C. SHALL RECEIVE THE SAME FINISHES AS

THE ADJACENT ROOM.4. CEMENTIOUS BACKER BOARD SHALL BE INSTALLED BELOW/ BEHIND ALL

CERAMIC TILE AT FLOORS AND WALLS.

NEW TYPE 'A' METAL STUD PARTITION.WITH 3-1/2" UNFACED SOUND BATTS

a

1. INFILL EXISTING OPENING IN FLOOR (APPROXIMATE LOCATION).REFER TO STRUCTURAL DWGS

2. EXISTING WINDOW OPENING ENLARGED FOR DOOR. REPAIRFLOOR. SEE A9/A350.

3. SEE FG/A501 FOR DETAIL OF TOP OF COLUMN AT DROPPEDCEILING.

4. EXISTING STEEL COLUMN PAINTED W/ INTUMESCENT PAINT FOR1 HOUR FIRE RATING. SEE E1/A401

5. EXISTING BEAM ABOVE, PAINTED. SEE G1/A401.

6. SHOWER: SHOWER FLOOR- PROVIDE WATERPROOF MEMBRANE,

MUDPAN AND CERAMIC TILE FLOOR SLOPED TO DRAIN. CERAMIC TILE SURROUND OVER CEMENT BACKER BD. TEMPERED GLASS SHOWER ENCLOSURE PER DEVELOPER

SPEC.

7. BUYER PROVIDED WASHER/ DRYER. SEE DETAIL A6/A501 FORREQUIREMENTS FOR DRYER EXHAUST MATERIALS AND LOCATION.

8. GAS COOK TOP W/ EXHAUST HOOD (400 CFM MAX). ROUTEEXHAUST INTO RATED SHAFT PER MECH DWGS.

9. WASH BASIN, SEE PLUMBING.

10. (3) 6" RISERS (NO HANDRAIL REQUIRED PER OBC 1009.12)SEE D9/A501

11. 8'-0" PARTIAL HEIGHT CLOSET WALL. SEE D6/A501

12. EXISTING BRICK WALL. CLEAN

13. ENTRY CANOPY BELOW. SEE A7/A340.

14. CLOSET SHELVING/ HANGROD(S) PER DEVELOPER SPECS.

15. CLOSET SHELVING PER DEVELOPER SPECS.

16. FLOOR MATERIAL TRANSITION STRIP.

17. CLEAN AND TUCK POINT EXISTING MASONRY WALL.

18. WINDOW WELL DRAIN AND OVERFLOW, SEE PLUMBING DWGS.

19. FIRE RATED SEMI-RECESSED FIRE EXTINGUISHER CABINET

20. STOREFRONT WINDOWS ABOVE- SEE INTERIOR ELEVATIONS.

21. DROPPED SOFFIT ABOVE DOOR AT 9'-0" AFF.

22. STAND PIPE - SEE FIRE PROTECTION DWGS.

23. 30" X 36" ROOF ACCESS HATCH INTO WINDOW WELL.

24. RAISED FLOOR AT FLEX ROOM, RAISED HALL, LAUNDRY ANDMECHANICAL. SEE F7/A103 AND D9/A501.

25. PROVIDE FULL DEPTH PATCH AS REQUIRED AT MASONRY WALLJOINT.

26. RECESSED MEDICINE CABINET. COORDINATE FRAMING.

27. THRESHOLD.

28. BURNISHED CMU STAIR/ ELEVATOR SHAFT- SEE F1/A102

29. SOUTH STAIR IS OPP HAND OF NORTH STAIR.

30. VERIFY DIMENSION AND COORDINATE SEQUENCING WITHWITH ELEVATOR MANUFACTURER.

31. WALL CABINETS ABOVE REFRIGERATOR AND OVEN SHALL BEFLUSH WITH OVEN CABINET. FRAME OUT WALL AS REQUIRED.SEE INTERIOR ELEVATION.

A. REFERENCE SPECIFICATION FOR ADDITIONAL INFORMATION.

B. BUILDING SHALL BE SPRINKLERED PER NFPA-13.

C. DIMENSIONS ARE TO FACE OF STUD OR FACE OF MASONRY UNLESS NOTEDOTHERWISE.

D. ALL INTERIOR UNIT PARTITIONS SHALL BE TYPE A UNLESS NOTED OTHERWISE.

E. ALL INTERIOR PARTITIONS SHALL BE 3-5/8" METAL STUDS UNLESS NOTEDOTHERWISE.

F. ALL INTERIOR PARTITIONS SHALL BE FULL HEIGHT TO MATCH EXISTING UNLESSNOTED OTHERWISE.

C. CEILINGS TO BE FULL HEIGHT UNLESS NOTED OTHERWISE. REFER TO REFLECTEDCEILING PLANS FOR DROPPED CEILING HEIGHTS AND LOCATIONS.

D. ALL DOOR JAMBS TO BE 4" FROM PERPENDICULAR WALL UNLESS NOTEDOTHERWISE

E. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AND DIMENSIONS IN THEFIELD. VERIFY ALL NEW FRAMING DIMENSIONS IN FIELD PRIOR TO INSTALLATION.NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO BEGINNING WORK.

F. INSTALL IN-WALL 2x BLOCKING AT ALL FIXED CABINETRY LOCATIONS AS WELL ASBATHROOM ACCESSORY LOCATIONS.

G. PROVIDE ALL REQUIRED THROUGH-PENETRATION AND FIRE STOP SYSTEMS FORCODE COMPLIANT COMPLETION OF THE WORK.

H. FRAMING AND IN-WALL PLUMBING PROVISIONS SHALL BE COORDINATED IN THEFIELD PRIOR TO THE INSTALLATION OF ROUGH-IN.

I. COORDINATE PLUMBING LAYOUTS TO ENSURE THAT ALL WATER, WASTE, ANDVENT PIPING IS CONCEALED WITHIN NEW OR EXISTING WORK.

J. COORDINATE LOCATIONS OF ALL EXTERIOR ENVELOPE PENETRATIONS PRIOR TOCOMMENCEMENT OF THE WORK, INCLUDING BUT NOT LIMITED TO ROOF VENTS,INTAKES, DRYER VENTS, ETC.

K. ALL DUCTS FOR BATH AND DRYER EXHAUST AND FRESH AIR INTAKE TO BE MAX4" Ø DIAMETER EXHAUST AND 26 GA STEEL. RANGE HOOD EXHAUST DUCTSSHALL BE 26 GA STEEL AND LOCATED WITHIN A FIRE RATED SHAFT PER THEDWGS.

L. SMOKE DETECTORS SHALL BE INSTALLED IN EACH SLEEPING ROOM, OUTSIDE OFEACH SLEEPING AREA IN THE IMMEDIATE VICINITY OF OF THE BEDROOMS. 110VOLT WITH BATTERY BACKUP. THE SMOKE ALARMS SHALL BE HARD-WIRED &INTERCONNECTED. SEE ELECTRIC DRAWINGS.

M. A CARBON MONOXIDE DETECTOR/ ALARM SHALL BE LOCATED OUTSIDE OF EACHSLEEPING AREA IN THE IMMEDIATE VICINITY OF OF THE BEDROOMS.

F6 KEY NOTES

3'-4"

F1 PARTIAL PLAN3/16"=1'-0" STAIR/ ELEVATOR SHAFT- CMU SCHEDULE

CMU SCHEDULE

A1 - COLOR A (DARK), BURNISHEDA2 - COLOR A (DARK), NON-BURNISHEDB1 - COLOR A (LIGHT), BURNISHEDB2 - COLOR A (LIGHT), NON-BURNISHEDC - STANDARD CMU

aa

BASEMENT: TYPE C1st - 4th: TYPE A1/ B1 PER INT ELEV

ROOF: TYPE A2/ B2 PER INT ELEVTOP 2 COURSES- A2

BASEMENT: TYPE C1st - 4th: TYPE B1ROOF: TYPE B2 BELOW CANOPY

TYPE A2 ABOVE CANOPY

BA

SEM

ENT:

TYP

E C

1st

- R

OO

F:TY

PE

B2

BA

SEM

ENT:

TYP

E C

1st

- R

OO

F:TY

PE

B2

BA

SEM

ENT:

TYP

E C

1st

FLO

OR

:TY

PE

A1

2nd

-RO

OF:

TYP

E A

2

ROOF (NOT SHOWN): A2

BA

SEM

ENT:

TYP

E C

1st

FLO

OR

:TY

PE

A1

2nd

-RO

OF:

TYP

E A

2

GENERAL NOTES:

1. WHERE CMU TYPES A1 AND A2 ARE USED, THE BURNISHED SIDE SHALL FACEOUTSIDE OF THE SHAFT.

2. AT STAIR CORRIDOR WALL USE TYPE A2 AT FLOOR FRAMING WHERE ENTIRELYCONCEALED FROM CORRIDOR.

3. AT ELEVATOR SHAFT TYPE C IN LIEU OF B1 MAY BE USED WHERE ENTIRE COURSE ISENTIRELY CONCEALED .

4. AT ROOF PATTERN WALL, USE TYPE A2 WHERE CMU IS CONCEALED IN ATTIC ANDBELOW THE FIN FLR OF THE ROOF DECK.

BASEMENT: TYPE C1st - 4th: TYPE A1/ B1 PER INT ELEV

ROOF: TYPE A2/ B2 PER INT ELEVTOP 2 COURSES- A2

Kitchen / break area

open work stations

Glass Enclosed Office

Glass Enclosed Office

open work stations

restrooms restrooms