Gulf Cable 2003

164
Click Here to NEXT PAGE

Transcript of Gulf Cable 2003

Page 1: Gulf Cable 2003

C l i c k H e r e t oN E X T P A G E

Page 2: Gulf Cable 2003

Gulf Cable & Electrical Industries Co. KSC was establishedin 1975 with the objective of meeting growing local requirementsand to provide users with quality wires and cables. Thecompany’s large and modern factory was commissioned inOctober 1979. Since then the activities of Gulf Cable, along withthe demand of it’s products in local as well as export marketshave been growing steadily and impressively. In 1985, a modernproduction unit to manufacture Low Voltage Cable Joints wasadded to the prevailing range of products.

In 1990, we were struck by disaster, the Iraqi invasion.However, we are proud to have risen from the ruins with stillgreater determination and commitment to quality. By procuringmost modern and sophisticated machinery and test equipment,we restored our full product range by mid 1992. The newmachinery has numerous built in functions and features; renderingprecision and consistency of highest standards.

Quality has always been our top priority and to meetcustomer’s expectations has been our prime objective; the verybasis on which we earned the confidence of our clientele in Gulfand Middle East region. Glittering accomplishments during recentpast speak for our strigent Quality Standards and consistency.We have been acknowledged by Kuwait Quality Mark issuedby Ministry of Commerce and Industries, Kuwait; and the mostcoveted recognition of International Quality Assurance SystemISO 9001, certified by RWTUV Germany.

Our Quality policy is to sustain and enhance our reputationfor product quality at competitive prices in National &International markets and to meet customer’s expectations.It is this concern and commitment rather than just sale of product,that has given GC a distinct image. The Quality of our productsalong with our commitment to timely deliveries is our competitiveadvantage and we shall continue to strive to maintain it.

I N T R O D U C T I O N

i C l i c k H e r e t oN E X T P A G E

Page 3: Gulf Cable 2003

MANUFACTURING PROCESS

COPPER RODSFrom copper cathodes direct to draw size (8.0 mm diameter)rods are produced through up cast continuous casting process.

CONDUCTORConductor manufacturing starts with wire drawingoperation. Copper or Aluminium rods are cold drawnthrough a series of dies to get desired size of wire.Continuous in-line annealing is done for copper tomake it soft.

Wires are then grouped together to get desiredconductor area and proper flexibility in a Standing orBunching Machine.

LAYING UPMulticore cables are made by laying together requirednumber of insulated conductors in a particulargeometric fashion.

INSULATIONCoating the conductor by suitable insulation is done byextrusion process. Materials adopted for insulationcoating are Polyvinyl chloride (PVC), cross linkedPolyethylene (XLPE) or Polyethylene (PE).

Choice of insulating material will depend uponapplication and properties required.

ARMOURINGArmouring , primarily provided for mechanical protectionto the cable, would be usually of galvanized steel wires.Galvanized steel tapes are also occasionally adopted.

iii C l i c k H e r e t oN E X T P A G E

Page 4: Gulf Cable 2003

MANUFACTURING PROCESS

OUTER SHEATHINGOutersheah or jacket is applied by the extrusionprocess. Most popular material is PVC due to itsexcellent chemical, flame resistant and fire retardantcharacteristics. In special cases such as telephonecables, polyethylene is used.

QUALITY CONTROLQuality Control department functions like watchdogof the organisation and it covers and effectively controlquality aspect of each and every activity right fromthe stage of purchasing of materials to despatch ofthe finished product.

Control procedures and sampling frequencies aredesigned as per internationally accepted rules andstrict quality standards are laid down in order to ensurea consistent, reliable and fault-free product to theutmost satisfaction of the customer. System isdesigned to take care of customers’ spacialrequirments, conformance to relevant national andinternational standards and our guaranteedcommitments.

Quality Control Department comprises of four majorsections viz.Raw Material Test LaboratoryIn process inspection cellFinal Inspection - Power CablesFinal - Inspection - Telephone Cables

PACKING & SHIPPINGThis is very important activity an a good attention ispaid to.

Strong and study wooden/steel drums are provided.Clear markings, identification, size and type of theproduct, drum number, weights, shipping instructionsand shipping marks etc. are carefully mark on thedrums.

Handling, storing and loading is done very carefullyand it is ensured that products are shipped without anydamages.

iv C l i c k H e r e t oN E X T P A G E

Page 5: Gulf Cable 2003

PRODUCT RANGE

We at Gulf Cable always aim for the best. While most of the Cable Manufacturers in Gulf and Middle East region settledfor ISO 9002, we stand out with ISO 9001 which recognizes our ability for Design & Development as well.

As a philosophy, our commitment to customers does not end with a sale. We also offer a host of related services beforeand after the sale. These include,

Aplication Engineering service for selection of appropriate product best suiting the end use. An extensive range of cables, single core wires, flexible cords, bare & insulated conductors manufactured to stringent

Quality Standards going beyond intrnational specifications. Design and Development of products tailored to meet specific requirments of the application. To help the customers understand the product intricacies and its performance levels.

NOTE 1: THE TABULATIONS ON SUBSEQUENT PAGES FURNISH OVERALL DIMENSIONS, NET & GROSS WEIGHTSAND DRUM DIMENSIONS. PLEASE NOTE THAT THESE ARE “APPROXIMATE” VALUES. THEY HAVE BEENFURNISHED FOR GENERAL GUIDELINES AND INTENDED TO BE USED FOR THUMB RULE ESTIMATIONS/FREIGHT CALCU LATIONS.

NOTE 2: VOLTAGE RATING:

TWO DISTINCT SYSTEMS OF VOLTAGE DESIGNATION ARE GENERALLY IN USE. EQUIVALENCE BETWEEN THESETWO SYSTEMS BASED ON INSULATION THICKNESS AND MAXIMUM VALUE OF HIGHHEST SYSTEM VOLTAGEIS AS TABULATED BELOW:

IEC DESIGNATION BS DESIGNATIONUo / U (Um) Uo/U (Um)

0.6/1 (1.2) KV 600 / 1000 (1200) V1.8/3 (3.6) KV 1900/3300 (3600) V3.6/6 (7.2) KV 3.8/6.6 (7.2) KV6/10 (12) KV 6.35/11 (12) KV8.7 / 15 (17.5) KV 8.7/15 (17.5) KV12/20 (24) KV 12.7/22 (24) KV18/30 (36) KV 19/33 (36) KV

Where,Uo is rated power frequency voltage between conductor and earth or metalic screen, for which cable is designed.

U is the rated power frequency voltage between conductors, for which the cable is designed.

Um is the maximum value of “highest system voltage” for which the equipment may be used.

FROM ABOVE TABULATION, EQUIVALENT IEC/BS DESIGNATION CAN BE DETERMINED FOR ANY SYSTEM ASAPPROPRIATE.

NOTE 3: THE FOLLOWING LIST TABULATES ONLY THE “STANDARD” PRODUCTS. FOR ANY PRODUCT NOTLISTED BELOW, PLEASE DO NOT HESITATE TO CONTACT OUR SALES & MARKETTING DIVISION. WE SHALL BETOO PLEASED TO MEET YOUR SPECIFIC REQUIREMENTS.

PRODUCT STANDARD

Medium Voltage Power Cables up to 30 KV

* XLPE insulated, single core or multicore armoured or un armoured cables IEC 60502 / BS 6622

Low Voltage Power Cables 600 / 1000 V

* PVC insulated PVC sheathed armoured / unarmoured cables BS 6346 / IEC 502

v C l i c k H e r e t oN E X T P A G E

Page 6: Gulf Cable 2003

PRODUCT RANGE

* XLPE insulated PVC sheathed armoured / unarmoured cables BS 5467 / IEC 502

* PVC or XLPE insulated PVC sheathed armoured / unarmouredauxiliary cables BS 6346 / BS 5467 / IEC 502

Control Cables 600 / 1000 V

* PVC insulated, shielded or non shielded control cables up to 91 cores BS 6346 / IEC 502

* XLPE Insulated, shielded or non shielded control cables up to 91 cores BS 5467 / IEC 502

Telephone , communication & Instrumentation cables

* PE insulated, star quadded, fully colour coded telephone cables ofarmoured, unarmoured or self supporting type MOC standards

* 16 core or 34 core pilot cables to be used alongwith undergroundpowerlines 11KV , 132 KV and beyond MEW / ESI Standards

* PE insulated pilot cables ESI Standards

* PE insulated communication cables and telemetry cables MEW / ESI Standards

* PVC insulated internal telephone cables MOC Standards

* Coaxial and data transmission cables Gulf Cables / Customer Standards

* PVC or PE insulated, screened or unscreened, armoured orunarmoured instrumentation cables BS 5308 / IEC 502

Bare Conductors for Overhead Lines

* Aluminium conductors steel reinforced ACSR BS 215 Part 2 / ASTM / CSA / DIN

* All aluminium conductors AAC BS 215 Part 1 / ASTM / CSA / DIN

* Hard drawn bare copper conductors HDBC BS 7884

Earthing Conductors

* Untinned or tinned bare copper conductors SDBC BS 6360 / IEC 228

PVC or XLPE Insulated conductors

* PVC or XLPE insulated conductors for earthing or over head lines BS 6485 / Customer Standards

Domestic Applications / Internal Wiring

* PVC Insulated non sheathed single core wires BS 6004 / BS 6231

* PVC Insulated PVC sheathed single or multicore cables BS 6004

* PVC Insulated PVC sheathed flexible cords BS 6500 / BS 6141 / BS 6004

* PVC Insulated PVC sheathed twin flat cables and cords with orwithout circuit protective conductors ( ECC) BS 6004

* PVC Insulated parellel twin cords BS 6500

Miscelleneous Applications

* Welding cables with copper conductor and insulated with rubberbased compound BS 638

* Fire survival cables IEC 502 / IEC 331

* Air port lighting cable Customer Standards

* Irrigation cable UL 493

* Cold pour resin compund and cable joints in the volatage rangeup to 1000 V AC and 1500 V DC BS 6910

PRODUCT STANDARD

vi C l i c k H e r e t oH O M E

Page 7: Gulf Cable 2003

CONTENTS

Introduction

Manufacturingf Process

Product Range

PRODUCT DATA TABLES

PVC INSULATED LOW VOLTAGE CABLESSingle Core Cables Cu/PVC and Cu/PVC/PVC ............................................................................................................. 12Single Core Cables Cu/PVC/PVC .................................................................................................................................. 13Single Core Cables Cu/PVC/PVC/AWA/PVC ................................................................................................................ 14Single Core Switchgear and Controlgear Cables Cu/ PVC............................................................................................ 15Single Core Flexible Cables Cu/PVC ............................................................................................................................. 16Single Core Flexible Cables for Switchgear and Controlgear Wiring Cu/PVC ............................................................... 17Single Core Cables AI/PVC/PVC/AWA/PVC .................................................................................................................. 18Two Core Cables Cu/PVC/ PVC .................................................................................................................................... 19Two Core CablesCu/PVC/PVC/SWA/PVC ..................................................................................................................... 20TwoCore Cables AI/PVC/PVC/SWA/PVC ...................................................................................................................... 21Two core Flexible Cords Cu/PVC/PVC .......................................................................................................................... 22Two Core Parallel Twin cables Cu/PVC ......................................................................................................................... 23Twin flat cables with and without Circuit Protective Conductor Cu/PVC//PVC............................................................... 24Three Core Cables Cu/PVC/PVC .................................................................................................................................. 25Three Core Cables Cu/ PVC/PVC/SWA/PVC and Cu/PVC/SWA/PVC ......................................................................... 26Three Core Flexible Cords Cu/PVC/PVC....................................................................................................................... 27Four Core Cables Cu/PVC/PVC .................................................................................................................................... 28Four Core Cables Cu/PVC/PVC/SWA/PVC and Cu/PVC/SWA/PVC ............................................................................ 29Four Core Flexible Cords Cu/PVC/PVC......................................................................................................................... 30Four Core Cables AI/PVC/PVC/SWA/PVC and AI/PVC/SWA/PVC ............................................................................... 31Four Core Cables with Reduced Neutral Cu/PVC/PVC ................................................................................................. 32Four CoreCables with Reduced Neutral Cu/PVC/PVC/SWA/PVC and Cu/PVC/SWA/PVC .......................................... 33Multicore Cables for Street Lighting Cu/PVC/PVC......................................................................................................... 34Five Core Flexible Cords Cu/PVC/PVC ......................................................................................................................... 35Irrigation Cable ............................................................................................................................................................... 36

XLPE INSULATED LOW VOLTAGE CABLESSingle Core Cables Cu/XLPE/PVC/ ............................................................................................................................... 38Single Core Cables Cu/XLPE/PVC/AWA/PVC............................................................................................................... 39Two Core Cables Cu/XLPE/PVC ................................................................................................................................... 40Two Core Cables Cu/XLPE/PVC/SWA/PVC .................................................................................................................. 41Three Core Cables Cu/ XLPE/PVC................................................................................................................................ 42Three Core Cables Cu/ XLPE/PVC/SWA/PVC and Cu/XLPE/SWA/PVC ..................................................................... 43Four Core Cables Cu/XLPE/PVC................................................................................................................................... 44Four Core Cables Cu/XLPE/PVC/SWA/PVC and Cu/XLPE/SWA/PVC ......................................................................... 45Four Core Cables AI/XLPE/PVC/SWA/PVC and AI/XLPE/SWA/PVC............................................................................ 46Four Core Cables with Reduced Neutral Cu/XLPE/PVC ............................................................................................... 47Four Core Cables with Reduced Neutral Cu/XLPE/PVC/SWA/PVC and Cu/XLPE/SWA/PVC ..................................... 48Four Core Cables with Reduced Neutral AI/XLPE/PVC/SWA/PVC and AI/XLPE/SWA/PVC ...................................... 49Multicore Cables for Street Lighting Cu/XLPE/PVC ....................................................................................................... 50

vii C l i c k H e r e t oN E X T P A G E

Page 8: Gulf Cable 2003

CONTENTS

AUXILARY, PILOT, COAXIAL AND DATA TRANSMISSION CABLES1.5 Sq.mm.Cables Cu/PVC/PVC ................................................................................................................................... 521.5 Sq.mm.Cables Cu/PVC/PVC/SWA/PVC .................................................................................................................. 531.5 Sq.mm.Cables Cu/PVC/PVC/CuT/PVC ................................................................................................................... 541.5 Sq.mm.Cables Cu/PVC/PVC/CuT/PVC/SWA/PVC ................................................................................................. 552.5 Sq.mm.Cables Cu/PVC/PVC ................................................................................................................................... 562.5 Sq.mm.Cables Cu/PVC/PVC/SWA/PVC .................................................................................................................. 572.5 Sq.mm.Cables Cu/PVC/PVC/CuT/PVC ................................................................................................................... 582.5 Sq.mm.Cables Cu/PVC/PVC/CuT/PVC/SWA/PVC ................................................................................................. 594 Sq.mm.Cables Cu/PVC/PVC ...................................................................................................................................... 604 Sq.mm.Cables Cu/PVC/PVC/SWA/PVC ..................................................................................................................... 611.5 Sq.mm.Cables Cu/XLPE/PVC ................................................................................................................................. 621.5 Sq.mm.Cables Cu/XLPE/PVC/SWA/PVC ................................................................................................................ 631.5 Sq.mm.Cables Cu/XLPE/PVC/Cut/PVC .................................................................................................................. 641.5 Sq.mm.Cables Cu/XLPE/PVC/Cut/PVC/SWA/PVC ................................................................................................. 652.5 Sq.mm.Cables Cu/XLPE/PVC ................................................................................................................................. 662.5 Sq.mm.Cables Cu/XLPE/PVC/SWA/PVC ................................................................................................................ 672.5 Sq.mm.Cables Cu/XLPE/PVC/Cut/PVC .................................................................................................................. 682.5 Sq.mm.Cables Cu/XLPE/PVC/Cut/PVC/SWA/PVC ................................................................................................. 694 Sq.mm.Cables Cu/XLPE/PVC .................................................................................................................................... 704 Sq.mm.Cables Cu/XLPE/PVC/SWA/PVC ................................................................................................................... 71Pilot cables -16 and 34 Core Cables.............................................................................................................................. 72Coaxial Cables for T.V/ Satellite Antenna etc. ................................................................................................................ 73Data Transmission Cables- 4 Pair 24 AWG ................................................................................................................... 74

MEDIUM VOLTAGE CABLESSingle Core cables 3.8 /6.6 KV. Cu/SC/XLPE/SC/AWA/PVC ........................................................................................ 76Three Core Cables 3.8 /6.6 KV. Cu/SC/XLPE/SC/AWA/PVC ....................................................................................... 77Single Core cables 6.35/11 KV. Cu/SC/XLPE/SC/AWA/PVC......................................................................................... 78Single Core cables 6.35/ 11KV. Cu/SC/XLPE/SC/CuT/PVC/AWA/PVC ........................................................................ 79Three Core Cables 6.35/ 11 KV. Cu/SC/XLPE/SC/SWA/PVC ....................................................................................... 80Three Core Cables 6.35/ 11 KV. Cu/SC/XLPE/SC/CuT/PVC/SWA/PVC ...................................................................... 81Three Core Cables 6.35/ 11 KV. AI/SC/XLPE/SC/SWA/PVC ......................................................................................... 82Three Core Cables 6.35/ 11 KV. AI/SC/XLPE/SC/CuT/PVC/SWA/PVC ........................................................................ 83Single Core Cables 8.7/15 KV. Cu/SC/XLPE/SC/AWA/PVC.......................................................................................... 84Single core Cables 8.7/15 KV. Cu/SC/XLPE/SC/CuT/PVC ........................................................................................... 85Single core Cables 8.7/15 KV. Cu/SC/XLPE/SC/CuT/PVC/AWA/PVC .......................................................................... 86Three Core Cables 8.7/15 KV. Cu/SC/XLPE/SC/CuT/PVC ........................................................................................... 87Three Core Cables 8.7/15 KV. Cu/SC/XLPE/SC/CuT/PVC/SWA/PVC .......................................................................... 88Three Core Cables 8.7/15 KV.AI/SC/XLPE/SC/CuT/PVC/SWA/PVC ............................................................................ 89Single Core Cables 12.7/22 KV. Cu/SC/XLPE/SC/CuT/PVC ......................................................................................... 90Three Core Cables 12.7/22 KV. Cu/SC/XLPE/SC/CuT/PVC ......................................................................................... 91Three Core Cables12.7/22 KV. Cu/SC/XLPE/SC/CuT/PVC/SWA/PVC ......................................................................... 92Three Core Cables12.7/22 KV. AI/SC/XLPE/SC/CuT/PVC/SWA/PVC .......................................................................... 93Single Core Cables19/33 KV. Cu/SC/XLPE/SC/CuT/PVC/AWA/PVC ........................................................................... 94Three Core Cables19/33 KV. Cu/SC/XLPE/SC/CuT/PVC/SWA/PVC ............................................................................ 95Three Core Cables19/33KV. AI/SC/XLPE/SC/CuT/PVC/SWA/PVC .............................................................................. 96

OVERHEAD TRANSMISSION CONDUCTORSHard Drawn Copper Conductors HDBC......................................................................................................................... 98PVC Covered Hard Drawn Copper Conductors HDBC/PVC ........................................................................................ 99All Aluminium Conductors AAC ........................................................................................................................... 100 - 104Aluminium Conductors Steel Reinforced ACSR.................................................................................................. 105 - 110Properties of Overhead Conductors- Modulas of Elasticity and Coefficient of Linear Expansion ............................... 111

viii C l i c k H e r e t oN E X T P A G E

Page 9: Gulf Cable 2003

CONTENTS

CONDUCTORS FOR EARTHINGSoft Drawn bare Copper Conuctors SDBC ................................................................................................................. 114

TELEPHONE CABLESTelephone Cables CCP-LAP & CCP-LAP-SS .............................................................................................................. 116Armoured Telephone Cables CCP-LAP-A ................................................................................................................... 117Internal network Cables ATC/PVC/PVC 0.5 mm. ......................................................................................................... 118

TECHNICAL INFORMATION

CURRENT RATINGSInstallation Conditions .........................................................................................................................................120 - 121Up to 1 KV Copper / Aluminium Conductor PVC / XLPE Insulated Single Core Cables and wires ............................. 1221 KV Copper / Aluminium Conductor PVC/ XLPE Insulated two core Armoured Cables ............................................. 1231 KV Copper / Aluminium Conductor PVC/ XLPE Insulated three / Four core Armoured Cables ................................ 1243.8 / 6.6 to 19/33 KV XLPE Insulated Cables ............................................................................................................. 125300/500 V Copper Conductor PVC Insulated Flexible Cords ..................................................................................... 126Rating Factors for Air, Ground and Duct ...................................................................................................................... 127Group Rating Factors ................................................................................................................................................... 128Rating Factors for Thermal Resistivity of Soil .....................................................................................................129 - 131

VOLATAGE DROPS1 KV PVC Insulated Cables ......................................................................................................................................... 1341 KV XLPE Insulated Cables ....................................................................................................................................... 135

AC RESISTANCE, RECATANCE AND CAPACITANCE VALUES0.6 /1.0 KV Cables ....................................................................................................................................................... 1383.8 / 6.6 KV and 6.35/11 KV Cables ............................................................................................................................ 1398.7 / 15 KV and 12.7/ 22 KV Cables ........................................................................................................................... 14019 / 33 KV Cables ........................................................................................................................................................ 141

SHORT CIRCUIT CURVESCopper Conductor PVC Insulated Cables.................................................................................................................... 144Copper Conductor XLPE Insulated Cables .................................................................................................................. 145Aluminium Conductor PVC Insulated Cables............................................................................................................... 146Aluminium Conductor XLPE Insulated Cables ............................................................................................................. 147

DRUMSDrum Sizes and Dimensions ........................................................................................................................................ 150

CABLE JOINTINGSGC Cable Joints ........................................................................................................................................................... 153Straight Through Joints ................................................................................................................................................ 155Branch / Service Joints ................................................................................................................................................ 157Double Branch / Service joints ..................................................................................................................................... 159Pilot Cable Joints ......................................................................................................................................................... 161Street Lighting Joints .................................................................................................................................................... 163Pot Ends....................................................................................................................................................................... 165Properties of BERPAK Cable jointing Compounds ...................................................................................................... 167Typical Performance Properties ................................................................................................................................... 168

ix C l i c k H e r e t oH O M E

Page 10: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

PVC INSULATED CABLES

C l i c k H e r e t oN E X T P A G E

Page 11: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

1.0† 18.1 0.6 2.5 15 0.8 4.5 31 100Y COIL 1.4 2.6

1.5* 12.1 0.7 3.0 21 0.8 4.9 39 100y ” 1.9 3.31.5 12.1 0.7 3.2 22 0.8 5.1 41 100Y ” 2.0 3.5

2.5* 7.41 0.8 3.6 32 0.8 5.5 52 100Y ” 2.9 4.62.5 7.41 0.8 3.8 34 0.8 5.7 55 100Y ” 3.1 4.94 4.61 0.8 4.3 49 0.9 6.4 76 100Y ” 4.5 6.6

6 3.08 0.8 4.9 68 0.9 7.0 98 100Y ” 6.2 8.710 1.83 1.0 6.0 115 0.9 8.3 150 100Y ” 10.5 13.816 1.15 1.0 7.1 170 1.0 9.6 215 100Y ” 15.5 19.7

Metre ± 10%25** 0.727 1.2 8.8 265 1.1 11.3 325 1000M D-9 - 38535 0.524 1.2 9.9 360 1.1 12.4 425 1000M D-10 420 48550 0.387 1.4 11.4 490 - - - 1000M D-9 550 -

70 0.268 1.4 13.0 690 - - - 1000M D-10 750 -95 0.193 1.6 15.3 950 - - - 500M D-9 535 -

120 0.153 1.6 16.8 1180 - - - 500M D-10 650

150 0.124 1.8 18.6 1480 - - - 500M D-10 800 -185 0.0991 2.0 20.6 1810 - - - 500M D-11 1010 -240 0.0754 2.2 23.5 2360 - - - 500m D-12 1290 -

300 0.0601 2.4 25.9 2960 - - - 500M D-12 1590 -400 0.0470 2.6 29.2 3820 - - - 500M D-16 2120 -500 0.0366 2.8 32.6 4810 - - - 500M D-18 2640 -

630 0.0283 2.8 38.2 6180 - - - 250M D-14 1700 -

450/750 V - SINGLE CORE NON SHEATHED AND300/500 V - SINGLE CORE SHEATHEDCOPPER CONDUCTOR PVC INSULATEDUNSHEATHED or PVC SHEATHED CABLES

(Cu/PVC or Cu/PVC/PVC)

† Circular solid conductor (Class 1) and 300/500V.* Circular solid conductor (Class 1).

All other conductors circular stranded or circular stranded compacted (Class 2).** 25 Sqmm Cu/PVC - 100 metre coil.

All the Cables are insulated with PVC Type 5 Heat Resisting 85ºC compound, which exceeds the rerquirement of BS 6004-1995Cables rated 450/750V are suitable for voltages up to 1000V a.c or up to 750V to earth d.c.Cables conform to BS 6004-1995 except 1.5 Sqmm & 2.5 Sqmm Cu/PVC/PVC with standard conductor.

NominalArea of

Conductor

Sqmm

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof

Insulation

mm

Approx.Overall

Diameter

mm

Approx.CableWeight

Kg/km

Thicknessof

Sheath

mm

Approx.Overall

Diameter

mm

StandardPackingLength

Yard/Metre

DrumSize/CoilApprox.

CableWeight

Kg/km

Cu/PVC Cu/PVC/PVC

Cu/PVC Cu/PVC/PVC

12

Approx.Gross Weight

KG

C l i c k H e r e t oN E X T P A G E

Page 12: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

13

1.5* 12.1 0.8 1.4 6.4 58 100 Y Coil 5.31.5 12.1 0.8 1.4 6.6 62 100 Y ” 5.7

2.5* 7.41 0.8 1.4 6.8 71 100 Y ” 6.52.5 7.41 0.8 1.4 7.0 75 100Y ” 6.94 4.61 1.0 1.4 7.9 100 100Y ” 9.1

6 3.08 1.0 1.4 8.5 125 100Y ” 11.410 1.83 1.0 1.4 9.2 170 100Y ” 15.516 1.15 1.0 1.4 10.3 235 100Y ” 21.0

Metre ± 10%25 0.727 1.2 1.4 12.0 345 1000 M D-10 40535 0.524 1.2 1.4 13.1 445 1000 M D-10 505

50 0.387 1.4 1.4 14.6 585 500 M D-8 34070 0.268 1.4 1.4 16.2 795 500 M D-9 46095 0.193 1.6 1.5 18.7 1090 500 M D-10 610

120 0.153 1.6 1.5 20.2 1330 500 M D-10 730150 0.124 1.8 1.6 22.2 1650 500 M D-11 930185 0.0991 2.0 1.7 24.4 2020 500 M D-12 1120

240 0.0754 2.2 1.8 27.5 2600 500 M D-12 1410300 0.0601 2.4 1.9 30.1 3230 500 M D-14 1770400 0.0470 2.6 2.0 33.6 4140 500 M D-16 2280

500 0.0366 2.8 2.1 37.4 5200 500 M D-18 1790630 0.0283 2.8 2.2 43.2 6660 250 M D-14 1820800 0.0221 2.8 2.3 47.4 8340 250 M D-16 2340

1000 0.0176 3.0 2.5 53.6 10600 250M D-18 2890

600/1000 V - SINGLE CORE

COPPER CONDUCTOR PVC INSULATEDPVC SHEATHED CABLES

(Cu/PVC/PVC)

* Circular solid conductor ( Class 1).All other conductors circular stranded or circular stranded compacted ( Class 2).All the cables are insulated with PVC Type 5 Heat Resisting 85ºC. Compound, and sheathed with PVCType 9 Heat Resisting compound suitable for Cables operating at a maximum conductor temprrature upto 90ºC.Sizes upto and including 35 Sqmm - conform to IEC 502 -1994.All other Cables confirm generally to BS 6346 - 1997 and IEC 502 - 1994.Colour of insulation and sheath black.

NominalArea of

Conductor

Sqmm

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof

Insulation

mm

Thicknessof

Outer Sheath

mm

Approx.Overall

Diameter

mm

Approx.CableWeight

Kg/km

StandardPackingLength

Yard/Metre

DrumSize/Coil

Approx.GrossWeight

KG

C l i c k H e r e t oN E X T P A G E

Page 13: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

50* 0.387 1.4 0.8 1.6 1.5 19.6 820 500 D-10 47070* 0.268 1.4 0.8 1.6 1.6 21.4 1060 500 D-10 59095* 0.193 1.6 0.8 1.6 1.6 23.7 1380 500 D-11 790

120 0.153 1.6 1.0 1.6 1.7 25.8 1680 500 D-12 950150 0.124 1.8 1.0 1.6 1.7 27.6 2020 500 D-12 1120185 0.0991 2.0 1.0 1.6 1.8 29.8 2420 500 D-12 1320

240 0.0754 2.2 1.0 1.6 1.9 32.9 3050 500 D-16 1740300 0.0601 2.4 1.0 1.6 1.9 35.3 3700 500 D-16 2060400 0.0470 2.6 1.2 2.0 2.1 40.2 4810 500 D-18 2650

500 0.0366 2.8 1.2 2.0 2.1 43.6 5900 500 D-18 3190630 0.0283 2.8 1.2 2.0 2.2 49.4 7460 250 D-16 2080800 0.0221 2.8 1.4 2.5 2.4 55.2 9450 250 D-18 2600

1000 0.0176 3.0 1.4 2.5 2.5 61.2 11820 250 D-18 3200

600/1000 V - SINGLE CORE

COPPER CONDUCTORPVC INSULATED ALUMINIUM WIRE ARMOUREDPVC SHETHED CABLES

(Cu/PVC/PVC/AWA/PVC)

All the cables are insulated with PVC Type 5 heat Resisting 85ºC ompound and sheathed with PVC Type 9 Heat Resisting compound suitable for cables operating at amaximum conductor temperature upto 90ºC, which exceeds the requirments of BS 6346-1997Colour of insulation and sheath black.* Cables generally to BS 6346 - 1997

All other Cables conform to BS 6346 - 1997

NominalArea of

Conductor

Sqmm

14

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof

Insulation

mm

Thickness ofExtrudedBedding

mm

ArmourWire

Diameter

mm

Thicknessof

Outer Sheath

mm

Approx.Overall

Diameter

mm

Approx.CableWeight

Kg/km

StandardPackingLength

Metre ± 10%

DrumSize

Approx.GrossWeight

KG

C l i c k H e r e t oN E X T P A G E

Page 14: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

15

CU 1.0 18.1 0.8 3.2 18 100 Coil 1.81.5 12.1 0.8 3.5 23 100 ” 2.32.5 7.41 0.8 3.9 32 100 ” 3.2

CR 2.5 7.41 0.8 4.2 34 100 ” 3.44 4.61 0.8 4.8 49 100 ” 4.96 3.08 0.8 5.4 68 100 ” 6.8

10 1.83 1.0 6.8 115 100 ” 1216 1.15 1.0 8.0 170 100 ” 1725 0.727 1.2 9.8 265 100 ” 27

Metre ± 10%35 0.524 1.2 11.0 360 1000 D-8 41050 0.387 1.4 13.0 490 1000 D-9 55070 0.268 1.4 15.0 685 1000 D-9 745

95 0.193 1.6 17.0 950 500 D-8 525120 0.153 1.6 19.0 1180 500 D-9 650150 0.124 1.8 21.0 1480 500 D-10 800

185 0.0991 2.0 23.5 1810 500 D-10 965240 0.0754 2.2 26.5 2360 500 D-11 1280

600/1000 V - SINGLE CORE

COPPER CONDUCTOR PVC INSULATEDCABLES FOR SWITCHGEAR ANDCONTROLGEAR WIRING TYPE CU AND CR AS PER BS 6231 - 1990

(Cu/ PVC)

Type CU: rigid, round, solid conductor as per Class 1 of BS 6360 - 1991.Type CR: rigid, round, stranded conductor as per Class 2 of BS 6360 - 1991.All the cables are insulated with PVC Type 5 Heat Rasisting 85ºC compound.Cables conform to BS 6231- 1990, AMD -1992.Above Cables as per BS 6231 - 1990, with PVC Type TI3, Heart Resisting 90ºC is available on request.

Type NominalArea of

Conductor

Sqmm

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof

Insulation

mm

MeanOverall

Diameter(Max.)

mm

Approx.CableWeight

Kg/km

StandardPackingLength

Metre

DrumSize/Coil

Approx.GrossWeight

KG

C l i c k H e r e t oN E X T P A G E

Page 15: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

1.5 13.3 0.7 3.4 21 100 Y Coil 1.92.5 7.98 0.8 4.1 33 100 Y ” 3.04 4.95 0.8 4.8 48 100 Y ” 4.4

6 3.3 0.8 5.3 70 100 Y ” 6.410 1.91 1.0 6.8 115 100 Y ” 1116 1.21 1.0 8.1 170 100 Y ” 16

25 0.780 1.2 10.2 270 100 Y ” 25Metre ± 5%

35 0.554 1.2 11.7 365 1000 M D-9 43050 0.386 1.4 13.9 505 1000 M D-10 570

70 0.272 1.4 16.0 700 1000 M D-11 80095 0.206 1.6 18.2 960 1000 M D-12 1070

120 0.161 1.6 20.2 1200 1000 M D-12 1310

150 0.129 1.8 22.5 1510 1000 M D-14 1660185 0.106 2.0 24.9 1830 1000 M D-14 1980240 0.0801 2.2 28.4 2390 1000 M D-18 2630

450/750 V SINGLE CORE FLEXIBLE CABLE

COPPER CONDUCTOR PVC INSULATED NON-SHEATHEDCABLES - TYPE -HO 7V-K OF BS 6004 - 1995

(Cu/Pvc)

All Conditions flexible (Class 5).All the Cables are insulated with PVC -Type 5, Heat Resisting 85ºC compound,which exceeds the requirmrnt of BS 6004 -1995.Cables conform to BS 6004 - 1995.

NominalArea of

Conductor

Sqmm

16

MaximumConductorResistance

Ohm/km

Thicknessof

Insulation

mm

MeanOverall

Diameter (Max.)

mm

Approx.Cable

Weight

Kg/km

StandardPackingLength

Yard/Metre

DrumSize/Coil

Approx.GrossWeight

KG

C l i c k H e r e t oN E X T P A G E

Page 16: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

17

600/1000 V - SINGLE CORE FLEXIBLE CABLES

COPPER CONDUCTOR PVC INSULATEDCABLES FOR SWITCHGEAR ANDCONTROLGEAR WIRING TYPE CK AS PER BS 6231 - 1990

( Cu/PVC)

All conductors are flexible (Class 5).All Cables are insulated with PVC Type 5 heat Resisting 85ºC compound.* Cables generally to BS 6231 - 1990.All other cables conform to BS 6231 - 1990 AMD No. 1 - 1992Above Cables insulated with PVC Type TI3 Heat Resisting 90ºC as per BS 6231-1990 are available on request.

0.5 39 0.8 3.0 12 100 Y Coil 1.10.75 26 0.8 3.2 15 100 Y ” 1.41.0 19.5 0.8 3.4 18 100 Y ” 1.6

1.5 13.3 0.8 3.7 23 100 Y ” 2.22.5 7.98 0.8 4.2 33 100 Y ” 3.04.0 4.98 0.8 4.8 48 100 Y ” 4.4

6 3.3 0.8 6.3 70 100 Y ” 6.410 1.91 1.0 7.8 115 100 Y ” 11.016 1.21 1.0 9.0 170 100 Y ” 16.0

25 0.78 1.2 11.5 270 100 Y ” 25Metre ± 5%

35 0.554 1.2 13.0 365 1000 M D-9 43050 0.386 1.4 15.0 505 1000 M D-10 570

70 0.272 1.4 17.5 700 1000 M D-12 81095 0.206 1.6 19.5 960 1000 M D-12 1070

120 0.161 1.6 21.5 1200 1000 M D-14 1350

150 0.129 1.8 24.0 1510 1000 M D-14 1660185 0.106 2.0 26.5 1830 1000 M D-16 2040240 0.0801 2.2 30.0 2390 1000 M D-18 2630

300* 0.0641 2.4 32.0 2990 500 M D-14 1650400* 0.0486 2.6 37.0 3940 500 M D-18 2210500* 0.0384 2.8 41.0 5020 500 M D-18 2750630* 0.0287 2.8 44.0 6070 250 M D-14 1670

NominalArea of

Conductor

Sqmm

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof

Insulation

mm

MeanOverall

Diameter (Max.)

mm

Approx.CableWeight

Kg/km

StandardPackingLength

Yard/Metre

DrumSize/Coil

Approx.GrossWeight

KG

C l i c k H e r e t oN E X T P A G E

Page 17: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

600/1000 V SINGLE CORE

ALUMINIUM CONDUCTORPVC INSULATED ALUMINIUM WIRE ARMOUREDPVC SHEATHED CABLES

(AI/PVC/PVC/AWA/PVC)

All conductors cirular stranded or circular stranded compacted (Class 2).All the Cables are insulated with PVC Type 5 Heat Resisting 85ºC compound and sheathed with PVC Type 9Heat Resisting compound suitable for Cable operating at a maximum conductor temperature upto90ºC,Which exceeds the requirments of BS 6346 - 1997 and IEC 502- 94.Color of insulation and sheath black.Cables conform to IEC 502 - 1994 and generally to BS 6346 -1997

50 0.641 1.4 1.0 1.6 1.8 20.6 580 500 D-10 35070 0.443 1.4 1.0 1.6 1.8 22.4 700 500 D-11 45095 0.320 1.6 1.0 1.6 1.8 24.6 845 500 D-12 535

120 0.253 1.6 1.0 1.6 1.8 26.0 955 500 D-12 590150 0.206 1.8 1.0 1.6 1.8 27.8 1100 500 D-12 660185 0.164 2.0 1.0 1.6 1.8 29.9 1280 500 D-12 750

240 0.125 2.2 1.0 1.6 1.9 33.0 1560 500 D-16 990300 0.100 2.4 1.2 2.0 2.0 36.7 1970 500 D-18 1230400 0.0778 2.6 1.2 2.0 2.1 40.4 2370 500 D-18 1430

500 0.0605 2.8 1.2 2.0 2.2 43.9 2830 500 D-18 1660630 0.0469 2.8 1.2 2.0 2.4 50.4 3570 250 D-18 1130800 0.0367 2.8 1.4 2.5 2.5 56.3 4480 250 D-18 1360

1000 0.0291 3.0 1.4 2.5 2.7 61.6 5410 250 D-18 1590

NominalArea of

Conductor

Sqmm

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof

Insulation

mm

Thickness ofExtrudedBedding

mm

ArmourWire

Diameter

mm

Thicknessof

Outer Sheath

mm

Approx.Overall

Diameter

mm

Approx.CableWeight

Kg/km

StandardPackingLength

Metre ± 10%

DrumSize

Approx.GrossWeight

KG

18C l i c k H e r e t o

N E X T P A G E

Page 18: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

19

1.5* 12.1 0.7 1.8 10.6 150 1000 D-8 200

1.5 12.1 0.7 1.8 11.0 160 1000 D-8 2102.5* 7.41 0.8 1.8 11.8 190 1000 D-8 2402.5 7.41 0.8 1.8 12.2 200 1000 D-9 260

4. 4.61 0.8 1.8 13.2 255 1000 D-10 3156 3.08 0.8 1.8 14.4 320 1000 D-10 380

10 1.83 1.0 1.8 16.6 460 1000 D-11 560

16 1.15 1.0 1.8 18.8 620 1000 D-12 73025** 0.727 1.2 1.8 22.2 910 500 D-11 55535** 0.524 1.2 1.8 24.4 1160 500 D-12 690

50** 0.387 1.4 1.8 27.9 1340 500 D-12 78070** 0.268 1.4 1.9 31.3 1810 500 D-14 106095** 0.193 1.6 2.0 36.1 2450 500 D-18 1470

120** 0.153 1.6 2.1 39.3 2990 500 D-18 1740150** 0.124 1.8 2.2 43.1 3680 500 D-18 2080185** 0.0991 2.0 2.4 47.5 4500 500 D-19 2570

240** 0.0754 2.2 2.5 53.5 5770 250 D-18 1650300** 0.0601 2.4 2.7 58.7 7150 250 D-18 2030400** 0.0470 2.6 2.9 65.7 9140 250 D-18 2530

600/1000 V -TWO CORE

COPPER CONDUCTOR PVC INSULATEDPVC SHEATHED CABLES

(Cu/PVC/PVC)

* circular solid conductor (Class !).All conductors circular stranded or circular stranded compacted (Class 2).All the Cables are nsulated with PVC Type 5 Heat Resisting 85ºC compound and sheathed with PVC Type 9HeatResisting compound suitable for Cables operating at a maximum conductor temperature upto 90ºC,which exceeds the requirments of BS 6346 - 1997 and IEC 502 - 1994.Cables upto and including 6 Sqmm generally to BS 6346 - 1997 and IEC 502 - 1994.All other Cables conform generally to BS 6346 - 1997** Cables with sector shaped conductors, having lesser overall dimensions, weight and cost are available on requist.

NominalArea of

Conductor

Sqmm

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof

Insulation

mm

Thicknessof

Outer Sheath

mm

Approx.Overall

Diameter

mm

Approx.CableWeight

Kg/km

StandardPackingLength

Metre ± 10%

DrumSize

Approx.GrossWeight

KG

C l i c k H e r e t oN E X T P A G E

Page 19: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

1.5* 12.1 0.7 0.8 0.9 1.3 12.6 305 1000 D-9 3651.5 12.1 0.7 0.8 0.9 1.4 13.2 310 1000 D-9 3702.5* 7.41 0.8 0.8 0.9 1.4 14.0 370 1000 D-10 4302.5 7.41 0.8 0.8 0.9 1.4 14.4 390 1000 D-10 450

4 4.61 0.8 0.8 0.9 1.4 15.4 460 1000 D-11 5606 3.08 0.8 0.8 0.9 1.5 16.8 550 1000 D-11 650

10 1.83 1.0 0.8 1.25 1.6 19.9 835 1000 D-12 945

16 1.15 1.0 0.8 1.25 1.6 22.1 1050 1000 D-14 120025** 0.727 1.2 1.0 1.6 1.7 26.8 1610 500 D-12 91535** 0.524 1.2 1.0 1.6 1.8 29.2 1950 500 D-12 1090

50** 0.387 1.4 1.0 1.6 1.9 32.7 2230 500 D-16 133070** 0.268 1.4 1.0 1.6 1.9 35.9 2790 500 D-18 164095** 0.193 1.6 1.2 2.0 2.1 42.1 3710 500 D-18 2200

120** 0.153 1.6 1.2 2.0 2.2 45.3 4580 500 D-19 2610150** 0.124 1.8 1.2 2.0 2.3 49.1 5410 500 D-19 3300185** 0.0991 2.0 1.4 2.5 2.4 54.4 6890 250 D-18 1960

240** 0.0754 2.2 1.4 2.5 2.5 60.7 8430 250 D-18 2350300** 0.0601 2.4 1.6 2.5 2.7 66.3 10140 250 D-18 2780400** 0.0470 2.6 1.6 3.15 2.9 73.3 12500 250 D-19 3450

600/1000 V - TWO CORE

COPPER CONDUCTORPVC INSULATED STEEL WIRE ARMOUREDPVC SHEATHED CABLES

(Cu/PVC/PVC/SWA/PVC)

NominalArea of

Conductor

Sqmm

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof

Insulation

mm

Thickness ofExtrudedBedding

mm

Diameterof Armour

Wire

mm

Thicknessof OuterSheath

mm

Approx.Overall

Diameter

mm

Approx.CableWeight

Kg/km

StandardPackingLength

Metre ± 10%

DrumSize

Approx.GrossWeight

KG

20

*Circular solid conductor (Class 1).All other conductors circular stranded or circular stranded compacted (Class 2).All the Cables are insulated with PVC Type 5 Heat Resisting 85ºC compound and sheathed with PVC Type 9Heat Resisting compound suitable for Cables operating at a maximum conductor temperature upto 90ºC,which exceeds the requirments of BS 6346 - 1997.Cables conform to BS 6346 - 1997** Cables with sector shaped conductor having lesser overall dimension, weight and cost are available on requist.

C l i c k H e r e t oN E X T P A G E

Page 20: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

16 1.91 1.0 1.0 1.25 1.8 22.9 915 1000 D-14 107025 1.20 1.2 1.0 1.6 1.8 27.0 1330 500 D-12 77535 0.868 1.2 1.0 1.6 1.8 29.2 1540 500 D-12 880

50 0.641 1.4 1.0 1.6 1.9 32.9 1680 500 D-16 105070 0.443 1.4 1.2 2.0 2.0 37.7 2300 500 D-18 139095 0.320 1.6 1.2 2.0 2.2 42.5 2790 500 D-18 1640

120 0.253 1.6 1.2 2.0 2.3 45.5 3150 500 D-19 1900150 0.206 1.8 1.4 2.5 2.4 50.7 4060 500 D-19 2350185 0.164 2.0 1.4 2.5 2.6 55.2 4710 250 D-18 1420

240 0.125 2.2 1.6 2.5 2.8 61.9 5700 250 D-18 1670300 0.100 2.4 1.6 2.5 2.9 66.8 6530 250 D-18 1870400 0.0778 2.6 1.6 2.5 3.2 74.3 7830 250 D-21 2380

500 0.0366 2.8 1.8 3.15 3.4 83.0 10170 200 D-22 2500

NominalArea of

Conductor

Sqmm

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof

Insulation

mm

Thickness ofExtrudedBedding

mm

Diameter ofArmour

Wire

mm

Thicknessof

Outer Sheath

mm

Approx.Overall

Diameter

mm

Approx.CableWeight

Kg/km

StandardPackingLength

Metre ± 10%

DrumSize

Approx.GrossWeight

KG

21

All conductors circular stranded or circular stranded compacted (Class 2).All the Cables are insulated with PVC Type 5 Heat Resisting 85ºC compound and sheathed with PVC Type 9Heat Resisting compound suitable for Cables operating at a maximum conductor temperature upto 90ºC,which exceeds the requirmrnts of BS 6346 - 1997Cables conform to IEC 502 - 1994 and generally to BS 6346 - 1997

600/1000 V TWO CORE

ALUMINIUM CONDUCTORPVC INSULATED STEEL WIRE ARMOUREDPVC SHEATHED CABLE

(AI/PVC/PVC/SWA/PVC)

C l i c k H e r e t oN E X T P A G E

Page 21: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

0.5 39.0 0.6 0.8 7.0 53 100 Coil

0.75 26.0 0.6 0.8 7.6 62 100 ”1.0 19.5 0.6 0.8 8.0 74 100 ”

1.25 15.6 0.7 0.8 8.6 88 100 ”1.5 13.3 0.7 0.8 9.0 95 100 ”2.5 7.98 0.8 1.0 11.0 140 100 ”

4 4.95 0.8 1.1 12.0 195 100 ”Metre ± 10%

6* 3.30 0.8 1.2 14.0 275 1000 D-1010* 1.91 1.0 1.4 17.5 435 1000 D-1216* 1.21 1.0 1.4 20.0 595 1000 D-12

300/500 V -TWO CORE FLEXIBLE CORDS

COPRER CONDUCTOR PVC INSULATEDPVC SHEATHED FLEXIBLE CORDS

(Cu/PVC/PVC)

NominalArea of

Conductor

Sqmm

22

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof

Insulation

mm

Thicknessof

Outer Sheath

mm

MeanOverall

Diameter Max.

mm

Approx.CableWeight

Kg/km

StandardPackingLength

Yard/Metre

Coil/DrumSize

All conductors flexible (Class 5).All Cables are insulated and sheathed with heat Resisting 85ºC PVC Type 4 compound.,*Cables generally conform to BS 6500 - 1994 and BS 6004 - 1995.All other Cables conform to BS 6500 - 1994, expect core identification, Red & Black.

C l i c k H e r e t oN E X T P A G E

Page 22: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

23

0.5 39.0 0.8 3.0 x 6.0 27 100

0.75 26.0 0.8 3.2 x 6.4 32 100

300/300V - PARALLEL TWIN

COPPEER CONDUCTOR PVC INSULATEDHO 3 VH - H AS PER BS 6500-1994

(Cu/PVC)

All conductors are flexible (Class 6).All Cables are insulated with Heat Resisting 85ºC PVC- Type 4 Compound.Cables conform to BS 6500 - 1994.

Nominal Areaof

Conductor

Sqmm

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof

Insulation

mm

OverallDimensions

of Cable (Max.)

mm

Approx.CableWeight

Kg/km

Standardcoil

Length

Yard

C l i c k H e r e t oN E X T P A G E

Page 23: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

300/500 V- TWIN FLAT CABLES

COPPER CONDUCTOR PVC INSULATEDPVC SHEATHED CABLESWITH AND WITH OUT CIRCUIT PROTECTIVE CNDUCTOR

( Cu/PVC/PVC)

1.0* 1.0 18.1 18.1 0.6 0.9 4.7 x 8.6 74 100 Coil1.5* 1.0 12.1 18.1 0.7 0.9 5.4 x 9.6 93 100 ”1.5 1.0 12.1 18.1 0.7 0.9 5.6 x 10.0 97 100 ”

2.5* 1.5 7.41 12.1 0.8 1.0 6.2 x 11.5 130 100 ”2.5 1.5 7.41 12.1 0.8 1.0 6.6 x 12.0 135 100 ”

4 1.5 4.61 12.1 0.8 1.0 7.2 x 13.0 175 100 ”6 2.5 3.08 7.41 0.8 1.1 8.0 x 15.0 235 100 ”

10 4 1.83 4.61 1.0 1.2 9.6 x 19.0 370 1000 Drum16 6 1.15 3.08 1.0 1.3 11.0 x 22.5 525 1000 ”

ConductorCircuit

ProtectiveConductor

ConductorCircuit

ProtectiveConductor

Thicknessof

Insulation

mm

Thicknessof

Outer Sheath

mm

OverallDimensions

of Cable(Max.)

mm

Approx.CableWeight

Kg/Km

StandardPacking

Length in Coil/Drum

Metre

*Circular solid conductor ( Class 1).All other conductores circular stranded (Clas 2).Circuit protective conductors - solid except for 10 Sqmm & 16 Sqmm cables.Colour of Insulation red and Black.Colour of sheath Grey or White.All the Cables are insulated with PVC Type 5 Heat Resisting 85ºC copmpound and sheathed with PVC Type 9Heat Resisting compound suitable for Cables operating at a maximum conductor temperature upto 90ºCwhich exceeds the requirments of BS 6004 - 1995Cables conform to BS 6004 -1995

Nominal Area Maximum Resistance at 20oC

1.0* 18.1 0.6 0.9 4.7 x 7.4 62 100 Coil1.5* 12.1 0.7 0.9 5.4 x 8.4 80 100 ”1.5 12.1 0.7 0.9 5.6 x 8.8 83 100 ”

2.5* 7.41 0.8 1.0 6.2 x 9.8 110 100 ”2.5 7.41 0.8 1.0 6.6 x 10.5 120 100 ”

4 4.61 0.8 1.0 7.2 x 11.5 155 100 ”6 3.08 0.8 1.1 8.0 x 13.0 205 100 ”

10 1.83 1.0 1.2 9.6 x 22.5 320 1000 Drum16 1.15 1.0 1.3 11.0 x 26.5 450 1000 ”

NominalArea of

Conductor

Sqmm

24

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof

Insulation

mm

Thicknessof

Outer Sheath

mm

OverallDimensions ofCable (Max.)

mm

Approx.CableWeight

Kg/km

StandardPacking Length

in Coil/Drum

Metre

WITHOUT CIRCUIT PROTECTIVE CONDUCTOR

Sqmm Ohm/km

WITH CIRCUIT PROTECTIVE CONDUCTOR (PREVIOUSLY ECC)

C l i c k H e r e t oN E X T P A G E

Page 24: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

25

1.5* 12.1 0.7 1.8 11.1 170 1000 D-8 2201.5 12.1 0.7 1.8 11.5 180 1000 D-9 2402.5* 7.41 0.8 1.8 11.9 225 1000 D-9 2852.5 7.41 0.8 1.8 12.4 235 1000 D-9 295

4 4.61 0.8 1.8 13.9 300 1000 D-10 3606 3.08 0.8 1.8 16.2 380 1000 D-11 480

10 1.83 1.0 1.8 17.6 560 1000 D-12 670

16 1.15 1.0 1.8 19.9 775 1000 D-12 88525 0.727 1.2 1.8 21.2 1050 500 D-10 58535 0.524 1.2 1.8 23.5 1360 500 D-11 780

50 0.387 1.4 1.8 27.1 1760 500 D-12 99070 0.268 1.4 2.0 29.7 2390 500 D-12 131095 0.193 1.6 2.1 34.5 3240 500 D-16 1830

120 0.153 1.6 2.2 37.7 3990 500 D-18 2240150 0.124 1.8 2.3 40.4 4900 500 D-18 2690185 0.0991 2.0 2.5 45.1 6040 250 D-16 1720

240 0.0754 2.2 2.6 51.4 7740 250 D-18 2180300 0.0601 2.4 2.8 56.1 9660 250 D-18 2660400 0.0470 2.6 3.1 63.7 12410 250 D-18 3340

500 0.0366 2.8 3.4 69.1 15480 250 D-18 4110

600/1000 V - THREE CORE

COPPER CONDUCTOR PVC INSULATEDPVC SHEATHED CABLES

Cu/PVC/PVC)

* Circular solid conductor ( Class 1).Conductors including 16 Sqmm circular stranded (Class 2).25 Sqmm and above shaped stranded conductors (Class 2).All the Cables are insulated with PVC Type 5 Heat Resisting 85o C compound and sheathed with Pvc Type 9Heat Resisting compound suitable for Cables operating at a maximum conductor temperature upto 90oC,which exceeds the requirmrnts of BS 6346 - 1997 and IEC 502 - 1994.Cables upto and including 6 Sqmm generally to BS 6346 - 1997 and IEC 502 - 1994.Cables, 10 Sqmm to 400 Sqmm conform generally to BS 6346 - 1997500 Sqmm Cable conforms to IEC 502 - 1994.

NominalArea of

Conductor

Sqmm

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof

Insulation

mm

Thicknessof

Outer Sheath

mm

Approx.Overall

Diameter

mm

Approx.CableWeight

Kg/km

StandardPackingLength

Metre ± 10%

DrumSize

Approx.GrossWeight

KG

C l i c k H e r e t oN E X T P A G E

Page 25: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

1.5* 12.1 0.7 0.8 - 0.9 1.4 13.3 - 340 - 1000 D-10 400 -1.5 12.1 0.7 0.8 - 0.9 1.4 13.7 - 355 - 1000 D-10 415 -2.5* 7.41 0.8 0.8 - 0.9 1.4 14.6 - 415 - 1000 D-10 475 -2.5 7.41 0.8 0.8 - 0.9 1.4 15.0 - 435 - 1000 D-10 495 -

4 4.61 0.8 0.8 - 0.9 1.4 16.1 - 515 - 1000 D-11 615 -6 3.08 0.8 0.8 - 1.25 1.5 18.3 - 720 - 1000 D-12 830 -

10 1.83 1.0 0.8 - 1.25 1.6 20.9 - 960 - 1000 D-12 1070 -

16 1.15 1.0 0.8 - 1.25 1.6 23.2 - 1240 - 1000 D-14 1390 -25 0.727 1.2 1.0 0.8 1.6 1.7 25.6 24.5 1670 1550 500 D-12 945 88535 0.524 1.2 1.0 0.8 1.6 1.8 28.1 27.0 2050 1920 500 D-12 1140 1070

50 0.387 1.4 1.0 0.8 1.6 1.9 31.9 30.8 2610 2460 500 D-14 1460 138070 0.268 1.4 1.2 0.8 2.0 2.0 35.5 34.0 3570 3360 500 D-16 2030 189095 0.193 1.6 1.2 0.8 2.0 2.1 40.3 38.8 4590 4360 500 D-18 2540 2420

120 0.153 1.6 1.2 0.8 2.0 2.2 43.5 42.0 5480 5230 500 D-18 2980 2860150 0.124 1.8 1.4 0.8 2.5 2.4 47.8 45.9 6940 6600 500 D-19 3790 3620185 0.0991 2.0 1.4 0.8 2.5 2.5 52.3 50.4 8270 7900 250 D-18 2310 2220

240 0.0754 2.2 1.6 0.8 2.5 2.6 59.0 56.7 10330 9870 250 D-18 2820 2710300 0.0601 2.4 1.6 0.8 2.5 2.8 63.7 61.4 12480 11950 250 D-18 3360 3230400 0.0470 2.6 1.6 0.8 2.5 3.0 71.1 68.8 15560 14970 200 D-19 3430 3310

500 0.0366 2.8 1.8 0.8 3.15 3.6 78.8 76.1 19910 19130 200 D-19 4300 4150

NominalArea of

Conductor

Sqmm

600/1000 V - THREE CORE

COPPER CONDUCTORPVC INSULATED ATEEL WIRE ARMOUREDPVC SHEATHED CABLES

(Cu/PVC/PVC/SWA/PVC and Cu/PVC/SWA/PVC)

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof

Insulation

mm

Diameterof

ArmourWire

mm

Thicknessof

OuterSheath

mm

StandardPackingLength

Metre ± 10%

DrumSize

Thickness ofBedding

mm

Approx.Overall Dia.

mm

Approx.Cable Weight

Kg/km

* Circular solid conductor ( Clas 1).Conductor including 16 Sqmm circular stranded (Class 2).25 Sqmm and above shaped stranded conductors (Class 2).All the Cables are insulated with PVC Type 5 heat Resisting 85ºC compound and sheathed with PVC Type 9 heat Resisting compound suitablefor Cables operating at a maximum conductor temperature upto 90ºC, which exceeds the requirments of BS 6346 - 1997.Drum size given above are for Cables with extruded bedding.Cables upto 400 Sqmm conform to 6346 - 1997500 sqmm Cable conforms to IEC 502 - 1994.

26

Approx. GrossWeight

Kg

ExtrudedBedding

LappedBedding

ExtrudedBedding

LappedBedding

ExtrudedBedding

LappedBedding

ExtrudedBedding

LappedBeeding

C l i c k H e r e t oN E X T P A G E

Page 26: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

0.5* 39.0 0.6 0.8 7.5 60 100 Coil0.75 26.0 0.6 0.8 8.0 75 100 ”1.0 19.5 0.6 0.8 8.4 85 100 ”

1.25 15.6 0.7 0.9 9.4 110 100 ”1.5 13.3 0.7 0.9 9.8 120 100 ”2.5 7.98 0.8 1.1 12.0 175 100 ”

4 4.95 0.8 1.2 13.0 240 1000 D-96* 3.30 0.8 1.4 15.5 350 1000 D-11

10* 1.91 1.0 1.4 19.0 535 1000 D-1216* 1.21 1.0 1.4 21.5 745 1000 D-14

NominalArea of

Conductor

Sqmm

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof

Insulation

mm

Thicknessof

Outer Sheath

mm

MeanOverall

Diameter Max.

mm

Approx.CableWeight

Kg/km

StandardPackingLength

Yard/Metre

Coil/DrumSize

27

300/500 V - THREE CORE FLEXIBLE CORDS

COPPER CONDUCTOR PVC INSULATEDPVC SHEATHED FLEXIBLE CORDS

(Cu/PVC/PVC)

All conductors flexible (Class 5).All Cables are insulated and sheathed with Heat Resisting 85ºC PVC Type 4 ccompound.*cables generally conform to BS 6500 - 1994 and BS 6004 - 1995All other Cables conform to BS 6500 - 1994 except core identification, Red, Black, Green.

C l i c k H e r e t oN E X T P A G E

Page 27: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

1.5* 12.1 0.7 1.8 11.9 200 1000 D-9 2601.5 12.1 0.7 1.8 12.3 210 1000 D-9 2702.5* 7.41 0.8 1.8 13.3 265 1000 D-10 3252.5 7.41 0.8 1.8 13.8 280 1000 D-10 340

4 4.61 0.8 1.8 15.0 360 1000 D-10 4206 3.08 0.8 1.8 16.5 465 1000 D-11 565

10 1.83 1.0 1.8 19.1 690 1000 D-12 800

16 1.15 1.0 1.8 21.8 970 500 D-10 54525 0.727 1.2 1.8 23.3 1290 500 D-11 74535 0.524 1.2 1.8 26.7 1700 500 D-12 960

50 0.387 1.4 1.9 30.3 2310 500 d-14 131070 0.268 1.4 2.0 33.4 3130 500 D-16 178095 0.193 1.6 2.2 38.8 4260 500 D-18 2370

120 0.153 1.6 2.3 41.7 5240 500 D-18 2860150 0.124 1.8 2.5 46.3 6490 500 D-19 3570185 0.0991 2.0 2.6 51.0 7980 250 D-18 2240

240 0.0754 2.2 2.8 56.6 10230 250 D-18 2800300 0.0601 2.4 3.1 62.0 12810 250 D-18 3440400 0.0470 2.6 3.3 69.8 16390 200 D-19 3600

500 0.0366 2.8 3.6 78.9 20500 200 D-19 4420

NominalArea of

Conductor

Sqmm

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof

Insulation

mm

Thicknessof

Outer Sheath

mm

Approx.Overall

Diameter

mm

Approx.CableWeight

Kg/km

StandardPackingLength

Metre ± 10%

DrumSize

Approx.GrossWeight

KG

600/1000 V - FOUR CORE

COPPER CONDUCTOR PVC INSULATEDPVC SHEATHED CABLES

(Cu/PVC/PVC)

* Circular solid conductor (Class 1).Conductors including 16 Sqmm circular stranded (Class 2).25 sqmm and above shaped stranded conductors ( Class 2).All the Cables are insulated with PVC Type 5 Heat Resisting 85ºC compound and sheathed with PVC Type 9Heat resisting compound suitablefor Cables operating at a maximum conductor temperature upto 90ºC,which exceeds the requirmentsof BS 6346 - 1997Cables upto and including 6 sqmm generally to BS 6346 - 1989 and IEC 502 - 1994.Cables 10 sqmm upto and including 400 Sqmm conform generally to BS 6346 - 1997500 sqmm Cable conforms to IEC 502 - 1994.

28C l i c k H e r e t o

N E X T P A G E

Page 28: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

1.5* 12.1 0.7 0.8 - 0.9 1.4 14.1 - 385 - 1000 D-10 445 -

1.5 12.1 0.7 0.8 - 0.9 1.4 14.5 - 400 - 1000 D-10 460 -2.5* 7.41 0.8 0.8 - 0.9 1.4 15.5 - 470 - 1000 D-11 570 -2.5 7.41 0.8 0.8 - 0.9 1.4 16.0 - 495 - 1000 D-11 595 -

4 4.61 0.8 0.8 - 1.25 1.5 18.1 - 700 - 1000 D-12 810 -6 3.08 0.8 0.8 - 1.25 1.5 19.6 - 830 - 1000 D-12 940 -

10 1.83 1.0 0.8 0.8 1.25 1.6 22.4 - 1130 - 1000 D-14 1280 -

16 1.15 1.0 1.0 0.8 1.6 1.7 26.4 - 1650 - 500 D-12 935 -25 0.727 1.2 1.0 0.8 1.6 1.8 27.9 26.8 2040 1890 500 D-12 1130 106035 0.524 1.2 1.0 0.8 1.6 1.9 31.5 30.4 2550 2400 500 D-14 1430 1350

50 0.387 1.4 1.2 0.8 2.0 2.0 36.3 34.8 3510 3300 500 D-16 1970 186070 0.268 1.4 1.2 0.8 2.0 2.1 39.4 37.9 4450 4220 500 D-18 2470 235095 0.193 1.6 1.2 0.8 2.0 2.2 44.6 43.1 5770 5510 500 D-18 3130 3000

120 0.153 1.6 1.4 0.8 2.5 2.4 49.1 47.2 7350 6970 500 D-19 4000 3810150 0.124 1.8 1.4 0.8 2.5 2.5 53.5 51.6 8760 8390 250 D-18 2430 2340185 0.0991 2.0 1.4 0.8 2.5 2.6 58.6 56.3 10530 10040 250 D-18 2870 2750

240 0.0754 2.2 1.6 0.8 2.5 2.8 64.2 61.9 13050 12520 250 D-18 3500 3370300 0.0601 2.4 1.6 0.8 2.5 3.0 70.0 67.7 15880 15300 250 D-19 4290 4150400 0.0470 2.6 1.8 0.8 3.15 3.3 79.1 76.4 20710 20000 200 D-19 4460 4320

500 0.0366 2.8 1.8 0.8 3.15 3.9 88.8 86.1 25400 24720 200 D-23 5580 5440

NominalArea of

Conductor

Sqmm

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof

Insulation

mm

Diameterof

ArmourWire

mm

Thicknessof

OuterSheath

mm

StandardPackingLength

Metre ± 10%

DrumSize

Thickness ofBedding

mm

Approx.Overall Dia.

mm

Approx.Cable Weight

Kg/Km

600/1000 V -FOUR CORE

COPPER CONDUCTORPVC INSULATED STEEL WIRE ARMOUREDPVC SHEATHED CABLES

(Cu/PVC/PVC/SWA/PVC and Cu/PVC/SWA/PVC)

Approx. GrossWeight

Kg

* Circular solid conductor (Class 1).Conductor including 16 Sqmm circular stranded (Class 2).25 Sqmmand above shaped stranded conductors (Class 2).All the Cables are insulated with PVC Type 5 Heat Resisting 85ºC compound and sheathed with PVC Type 9 Heat Resisting compound suitablefor Cables operating at a maximum conductor temperature upto 90ºC, which exceeds the requirments of BS 6346 - 1997Drum Size given above are for Cables with extruded bedding.Cables upto and including 400 Sqmm conform to BS 6346 - 1997500 sqmm Cable conforms to IEC 502 - 1994

29

ExtrudedBedding

LappedBedding

ExtrudedBedding

LappedBedding

ExtrudedBedding

LappedBedding

ExtrudedBedding

LappedBeeding

C l i c k H e r e t oN E X T P A G E

Page 29: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

0.75 26.0 0.6 0.8 8.6 90 100 Coil1.0 19.5 0.6 0.9 9.4 105 100 ”

1.5 13.3 0.7 1.0 11.0 150 100 ”2.5 7.98 0.8 1.1 13.0 210 100 ”

4 4.95 0.8 1.2 14.0 290 1000 D-106* 3.30 0.8 1.4 17.0 430 1000 D-11

10* 1.91 1.0 1.4 20.5 660 1000 D-1216* 1.21 1.0 1.4 23.5 925 1000 D-14

NominalArea of

Conductor

Sqmm

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof

Insulation

mm

Thicknessof

Outer Sheath

mm

MeanOverall

Diameter Max.

mm

Approx.CableWeight

Kg/km

StandardPackingLength

Metre

Coil/DrumSize

300/500 V-FOUR CORE FLEXIBLE CORDS

COPPER CONDUCTOR PVC INSULATEDPVC SHEATHED FLEXIBLE CORDS

(Cu/PVC/PVC)

All conductors flexible (Class 5).All Cables are insulated and sheathed with Heat Resisting 85ºC PVC Type 4 compound.* Cables generally conform to BS 6500 - 1994 and BS 6004 - 1995.All other Cables conform to BS 6500 - 1994, except core identification, Red. Yellow, Blue, Black.

30C l i c k H e r e t o

N E X T P A G E

Page 30: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

25 1.20 1.2 1.0 0.8 1.6 1.8 27.9 26.8 1420 1310 500 D-12 820 765

35 0.868 1.2 1.0 0.8 1.6 1.9 31.3 30.2 1720 1580 500 D-14 1010 94050 0.641 1.4 1.2 0.8 2.0 2.1 36.5 35.0 2400 2190 500 D-18 1440 1335

70 0.443 1.4 1.2 0.8 2.0 2.2 39.6 38.1 2840 2620 500 D-18 1660 155095 0.320 1.6 1.2 0.8 2.5 2.4 45.7 44.2 3910 3600 500 D-19 2200 2040

120 0.253 1.6 1.4 0.8 2.5 2.5 49.3 47.4 4470 4110 500 D-19 2560 2380

150 0.206 1.8 1.4 0.8 2.5 2.7 52.1 50.2 5050 4710 500 D-19 2850 2680185 0.164 2.0 1.6 0.8 2.5 2.9 59.0 56.7 6080 5650 500 D-22 3510 3300240 0.125 2.2 1.6 0.8 2.5 3.1 65.0 62.7 7310 6800 250 D-18 2070 1940

300 0.100 2.4 1.6 0.8 2.5 3.3 70.6 68.3 8590 8050 250 D-21 2570 2430400 0.0778 2.6 1.8 0.8 3.15 3.6 79.7 77.0 11180 10810 200 D-19 2560 2480500 0.0605 2.8 1.8 0.8 3.15 3.9 88.9 86.1 13690 12690 200 D-21 3160 2960

NominalArea of

Conductor

Sqmm

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof

Insulation

mm

Diameterof

ArmourWire

mm

Thicknessof

OuterSheath

mm

StandardPackingLength

Metre ± 10%

DrumSize

Thickness ofBedding

mm

Approx.Overall Dia.

mm

Approx.Cable Weight

Kg/Km

Approx. GrossWeight

Kg

All the conductors shaped stranded (Class 2).All the Cables are insulated with PVC Type 5 Heat Resisting 85ºC compound and sheathed with PVC Type 9 Heat Resisting compoundsuitable for Cables operating at a maximum conductor temperature upto 90ºC.Drum size given above are for Cables with extruded bedding.Cables conform to IEC 502 - 1994.

31

600/1000 V - FOUR CORE

ALUNINIUM CONDUCTORPVC INSULATED STEEL WIRE ARMOUREDPVC SHEATHED CABLES

(AI/PVC/PVC/SWA/PVC and AI/PVC/SWA/PVC

ExtrudedBedding

LappedBedding

ExtrudedBedding

LappedBedding

ExtrudedBedding

LappedBedding

ExtrudedBedding

LappedBeeding

C l i c k H e r e t oN E X T P A G E

Page 31: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

10* 6 1.83 3.08 1.0 1.0 1.8 18.2 540 1000 D-12 65016* 10 1.15 1.83 1.0 1.0 1.8 20.7 760 500 D-10 44025* 16 0.727 1.15 1.2 1.0 1.8 23.3 1140 500 D-11 670

35 16 0.524 1.15 1.2 1.0 1.8 26.7 1450 500 D-12 83550 25 0.387 0.727 1.4 1.2 1.9 30.3 1970 500 D-12 110070 35 0.268 0.524 1.4 1.2 2.0 33.4 2690 500 D-16 1560

95 50 0.193 0.387 1.6 1.4 2.1 38.6 3650 500 D-18 2070120 70 0.153 0.268 1.6 1.4 2.2 41.5 4570 500 D-18 2530150 70 0.124 0.268 1.8 1.4 2.4 46.6 5560 500 D-19 3100

185 95 0.0991 0.193 2.0 1.6 2.5 51.3 6900 250 D-18 1970240 120 0.0754 0.153 2.2 1.6 2.7 56.9 8820 250 D-18 2450300 150 0.0601 0.124 2.4 1.8 2.9 63.1 11050 250 D-18 3000

300 185 0.0601 0.0991 2.4 2.0 3.0 63.3 11370 250 D-18 3080400 185 0.0470 0.0991 2.6 2.0 3.2 70.5 14110 200 D-19 3140

Phase conductor upto 16 Sqmm circular stranded ( Class 2).Phase conductor 25 Sqmm and above shaped stranded (Class 2).All neutral conductors circular stranded (Class 2).All the Cables are insulated with PVC Type 5 Heat Resisting 85ºC compound and sheathed with PVC Type 9Heat Resisting compound suitable for Cables operating at a maximum conductor temperature upto 90ºC,which exceeds the requirments of BS 6346 - 1997*Cables conform to IEC 502 - 1994.All other Cables conform generally to BS 6346 - 1997 and IEC 502 - 1994.

Nominal Area ofConductor

Thicknessof OuterSheath

mm

Approx.CableWeight

Kg/km

StandardPackingLength

Metre ± 10%

Approx.Overall

Diameter

mm

DrumSize

Approx.GrossWeight

KG

32

600/1000 V - FOUR CORE WITH REDUCED NEUTRAL

COPPER CONDUCTOR PVC INSULATEDPVC SHEATHED CABLES

(Cu/PVC/PVC)

Thickness ofInsulation

Sqmm Ohm/Km mm

Phase NeutralPhase Neutral Phase Neutral

Maximum ConductorResistance at 20ºC

C l i c k H e r e t oN E X T P A G E

Page 32: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

Nominal Areaof Conductor

MaximumConductorResistance at 20ºC

Thicknessof Insulation

Thicknessof Bedding

Dia. ofArmour

Wire

Thicknessof

OuterSheath

Approx.Overall Dia.

Approx. CableWeight

StandardPackingLength

DrumSize

Approx.Gross Weight

Phase Neutral Phase Neutral Phase Neutral Extruded Lapped ExtrudedBedding

LappedBedding

ExtrudedBedding

LappedBedding

ExtrudedBedding

LappedBedding

Sqmm Okh/km mm mm mm mm mm Kg/Km Metre±10% Kg

10* 6 1.83 3.08 1.0 1.0 1.0 - 1.25 1.8 22.7 - 1080 - 1000 D-14 1230 -16* 10 1.15 1.83 1.0 1.0 1.0 - 1.6 1.8 25.9 - 1530 - 500 D-12 875 -25 16 0.727 1.15 1.2 1.0 1.0 0.8 1.6 1.8 27.9 26.8 1930 1810 500 D-12 1080 102035 16 0.524 1.15 1.2 1.0 1.0 0.8 1.6 1.8 31.3 30.2 2360 2230 500 D-14 1330 127050 25 0.387 0.727 1.4 1.2 1.0 0.8 1.6 1.9 34.9 33.8 3020 2870 500 D-16 1720 165070 35 0.268 0.524 1.4 1.2 1.2 0.8 2.0 2.0 39.2 37.7 4130 3920 500 D-18 2310 2200

95 50 0.193 0.387 1.6 1.4 1.2 0.8 2.0 2.2 44.6 43.1 5340 5110 500 D-18 2910 2800120 70 0.153 0.268 1.6 1.4 1.4 0.8 2.5 2.3 48.9 47.0 6860 6500 500 D-19 3750 3570150 70 0.124 0.268 1.8 1.4 1.4 0.8 2.5 2.4 53.8 51.9 8090 7740 500 D-19 4370 4190

185 95 0.0991 0.193 2.0 1.6 1.4 0.8 2.5 2.5 58.5 56.6 9700 9330 250 D-18 2670 2570240 120 0.0754 0.153 2.2 1.6 1.6 0.8 2.5 2.7 64.5 62.2 11990 11540 250 D-18 3240 3130300 150 0.0601 0.124 2.4 1.8 1.6 0.8 2.5 2.9 70.7 68.4 14620 14080 250 D-21 4080 3940

300 185 0.0601 0.0991 2.4 2.0 1.6 0.8 2.5 2.9 70.7 68.4 14930 14390 250 D-21 4150 4020400 185 0.0470 0.0991 2.6 2.0 1.8 0.8 3.15 3.1 79.6 76.9 18970 18310 200 D-19 4110 3980

600/1000 V - FOUR CORE WITH REDUCED NEUTRAL

COPPER CONDUCTORPVC INSULATED STEEL WIRE ARMOUREDPVC SHEATHED CABLES

(Cu/PVC/PVC/SWA/PVC and Cu/PVC/SWA/PVC)

Phase conductor upto 16 Sqmm circular stranded ( Class 2).Phase conductor 25 Sqmm and above shaped stranded ( Class 2).All neutral conductors circular stranned ( Class 2).All the Cables are insulated with PVC Type 5 Heat Resisting 85ºC compound and sheathed with PVC Type 9 Heat Resisting compoundsuitable for Cables operating at a maximum conductor temperature upto 90ºC, which exceeds the requirments of BS 6346 - 1997Drum size given above are for Cables with extruded bedding.*Cables conform to IEC 502 - 1994.All other Cables conform to BS 6346 - 1997

33C l i c k H e r e t o

N E X T P A G E

Page 33: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

Cable Details

Sqmm Metre±10%

2x16+1x10 16 10 1.15 1.83 1.0 1.0 1.8 19.9 735 1000 D-12 830

3x25+2x16 25 16 0.727 1.15 1.2 1.0 1.8 28.3 1620 500 D-12 920

3x35+2x16 35 16 0.524 1.15 1.2 1.0 1.9 32.0 2070 500 D-14 1190

Nominal Areaof Conductor

MaximumConductorResistance at 20ºC

Thicknessof Insulation

Thicknessof

OuterSheath

Approx.Overall

Diameter

Approx.CableWeight

StandardPackingLength

DrumSize

Approx.GrossWeightPhase Neutral

& EarthPhase Neutral

& EarthPhase Neutral

& Earth

Ohm/Km mm mm mm Kg/Km Kg

600/1000 V - MULTICORE CABLES FOR STREET LIGHTING

COPPER CONDUCTOR PVC INSULATEDPVC SHEATHED CABLES

(Cu/PVC/PVC)

Cable Details Nominal Areaof

Conductor

MaximumConductorResistance

at 20ºC

Thicknessof

Insulation

Thicknessof

Outer Sheath

Approx.Overall

Diameter

Approx.CableWeight

StandardPackingLength

DrumSize

Approx.GrossWeight

5x1.5* 1.5 12.1 0.7 1.8 12.7 230 1000 D-9 2905x1.5 1.5 12.1 0.7 1.8 13.2 240 1000 D-9 3005x2.5* 2.5 7.41 0.8 1.8 13.8 290 1000 D-10 3505x2.5 2.5 7.41 0.8 1.8 14.9 325 1000‘ D-10 385

5x4 4 4.61 0.8 1.8 16.2 420 1000 D-11 5205x6 6 3.08 0.8 1.8 17.8 545 1000 D-12 6555x10 10 1.83 1.0 1.8 20.8 835 500 D-10 480

5x16 16 1.15 1.0 1.8 23.8 1170 500 D-11 6855x25 25 0.727 1.2 1.9 26.2 1630 500 D-12 9255x35 35 0.524 1.2 2.0 31.5 2310 500 D-14 1310

Sqmm Ohm/Km mm mm mm Kg/Km Metre±10% Kg

*Circular solid conductors (Class 1).all other conductors circular stranded (Class 2).All the Cables are insulated with PVC Type 5 Heat Resisting 85ºC compound and sheathed with PVC Type 9 Heat Resisting compound suitable for Cables operating upto amaximum conductor temperature of 90ºC.Cables conform generally to IEC 502 - 1994.

34C l i c k H e r e t o

N E X T P A G E

Page 34: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

0.75 26.0 0.6 0.9 9.6 125 100 Coil1.0 19.5 0.6 0.9 10.0 145 100 ”

1.5 13.3 0.7 1.1 12.0 205 100 ”

Metre ± 10%

2.5 7.98 0.8 1.2 14.0 290 1000 D-104 4.95 0.8 1.4 15.5 410 1000 D-11

NominalArea of

Conductor

Sqmm

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof

Insulation

mm

Thicknessof

Outer Sheath

mm

MeanOverall

Diameter Max.

mm

Approx.CableWeight

Kg/km

StandardPackingLength

Metre

Coil/DrumSize

300/500 V - FIVE CORE FLEXIBLE CORDS

COPPER CONDUCTOR PVC INSULATEDPVC SHEATHED FLEXIBLE CORDS

(Cu/PVC/PVC)

All conductors flexible (Class 5).All Cables are insulated and sheathed with Heat Resisting 85ºC PVC Type 4 compound.Core identification, Red, Yellow, Blue, Black, Green.All Cables conform to BS 6500 - 1994.

35C l i c k H e r e t o

N E X T P A G E

Page 35: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

IRRIGATION CABLEIN LINE WITH UL SPECIFICATION NO 493 - 1995

Suitable for direct burial applications like irrigation systems, commercial sprinklers etc.

Conductor: Circular Solid / Stranded Annealed Copper

Insulation: HR PVC type 5 (Equivalent to UL 493 600 V grade)

Tested for AC spark test, Insulation Resistance and Flammability as per IEC: 332 - I

Insulation Colors to choose from: Green/Yellow, Green, White, Natural Gray, Red, Black or any orther color as required.

Identification: IRRIGATION CABLE xx AWG UF 600 V GULF CABLE KUWAIT

(where xx indicates conductor size)

Packing: Available in Spools / Shrink Wrap coils as required in mutally agreed lengths.

NominalConductor

Cross Section

AWG

NominalInsulationThickness

mm

OverallDiameter(Approx)

mm

Net Weight(Approx)

Kg/km

DC Resistance at20 deg C

(Maximum)

Ohm/km

14 1.6 5.0 45 8.45

12 1.6 5.5 60 5.33

10 1.6 6.0 83 3.25

Note: For any conductor cross section other than listed above, you are welcome to contact our Marketing Department.

36C l i c k H e r e t o

H O M E

Page 36: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

XLPE INSULATED CABLES

C l i c k H e r e t oN E X T P A G E

Page 37: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

600/1000 V - SINGLE CORE

COPPER CONDUCTOR XLPE INSULATEDPVC SHEATHED CABLES

(Cu/XLPE/PVC)

38

1.5* 12.1 0.7 1.4 6.5 57 100 Y Coil 5.21.5 12.1 0.7 1.4 6.7 60 100 Y ” 5.62.5* 7.41 0.7 1.4 6.9 69 100 Y ” 6.42.5 7.41 0.7 1.4 7.1 72 100 Y ” 6.7

4 4.61 0.7 1.4 7.6 90 100 Y? ” 8.36 3.08 0.7 1.4 8.2 115 100 Y ” 10.6

10 1.83 0.7 1.4 8.9 160 100 Y ” 14.7

16 1.15 0.7 1.4 10.0 220 1000 M D-8 27025 0.727 0.9 1.4 11.6 320 1000 M D-9 38035 0.524 0.9 1.4 12.7 420 1000 M D-9 480

50 0.387 1.0 1.4 14.0 550 1000 M D-10 61070 0.268 1.1 1.4 15.8 760 1000 M D-11 86095 0.193 1.1 1.5 17.9 1030 500 M D-9 575

120 0.153 1.2 1.5 19.6 1270 500 M D-10 695150 0.124 1.4 1.6 21.6 1580 500 M D-10 850185 0.0991 1.6 1.6 23.6 1920 500 M D-11 1060

240 0.0754 1.7 1.7 26.5 2470 500 M D-12 1350300 0.0601 1..8 1.8 28.9 3080 500 M D-12 1650400 0.0470 2.0 1.9 32.4 3960 500 M D-16 2190

500 0.0366 2.2 2.0 36.0 4970 500 M D-18 2730630 0.0283 2.4 2.2 42.4 6420 500 M D-18 3450800 0.0221 2.6 2.3 47.0 8090 250 M D-16 2240

1000 0.0176 2.8 2.4 53.0 10280 250 M D-18 2810

NominalArea of

Conductor

Sqmm

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof

Insulation

mm

Thicknessof

Outer Sheath

mm

Approx.Overall

Diameter

mm

Approx.CableWeight

Kg/km

StandardPackingLength

Yard/Metre ± 10%

DrumSize/Coil

Approx.GrossWeight

Kg

*Circular solid conductor (Class 1).All other conductors circular stranded or circular stranded compacted (Class 2).Cables upto and including 35 Sqmm conform to IEC 502 - 1994.All other Cables conform generally to BS 5467 - 1997 and IEC 502 - 1994.Colour of Insulation is natural colour

C l i c k H e r e t oN E X T P A G E

Page 38: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

50 0.387 1.0 0.8 1.6 1.5 18.8 765 500 D-10 44570 0.268 1.1 0.8 1.6 1.5 20.6 1000 500 D-10 56095 0.193 1.1 0.8 1.6 1.6 22.7 1300 500 D-11 750

120 0.153 1.2 0.8 1.6 1.6 24.4 1560 500 D-12 890150 0.124 1.4 1.0 1.6 1.7 26.8 1920 500 D-12 1070185 0.0991 1.6 1.0 1.6 1.8 29.0 2300 500 D-12 1260

240 0.0754 1.7 1.0 1.6 1.8 31.7 2890 500 D-14 1600300 0.0601 1.8 1.0 1.6 1.9 34.1 3530 500 D-16 1980400 0.0470 2.0 1.2 2.0 2.0 38.8 4590 500 D-18 2540

500 0.0366 2.2 1.2 2.0 2.1 42.4 5660 500 D-18 3070630 0.0283 2.4 1.2 2.0 2.2 48.6 7100 250 D-16 1990800 0.0221 2.6 1.4 2.5 2.4 54.0 9030 250 D-18 2500

1000 0.0176 2.8 1.4 2.5 2.5 60.8 11500 250 D-18 3120

NominalArea of

Conductor

Sqmm

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof

Insulation

mm

Thickness ofExtrudedBedding

mm

Diaof

ArmourWire

mm

Thicknessof

Outer Sheath

mm

Approx.Overall

Diameter

mm

Approx.CableWeight

Kg/km

StandardPackingLength

Metre ± 10%

DrumSize

Approx.GrossWeight

KG

600/1000 V SINGLE CORE

COPPER CONDUCTOR XLPE INSULATEDALUMINIUM WIRE ARMOUREDPVC SHEATHED CABLES

Cu/XLPE/PVC/AWA/PVC)

Circular stranded or circular stranded compacted (Class 2).Cables upto and including 120 Sqmm conform to IEC 502 - 1994.All other Cables conform to BS 5467 - 1997 and generally to IEC 502 - 1994Colour of insulation is natural colour.

39C l i c k H e r e t o

N E X T P A G E

Page 39: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

1.5* 12.1 0.7 1.8 10.8 150 1000 D-8 2001.5 12.1 0.7 1.8 11.2 170 1000 D-9 2302.5* 7.41 0.7 1.8 11.6 180 1000 D-9 2402.5 7.41 0.7 1.8 12.0 190 1000 D-9 250

4 4.61 0.7 1.8 13.0 240 1000 D-9 3006 3.08 0.7 1.8 14.2 300 1000 D-10 360

10 1.83 0.7 1.8 15.6 405 1000 D-11 505

16 1.15 0.7 1.8 17.8 565 1000 D-12 67525 0.727 0.9 1.8 21.0 825 500 D-11 51535 0.524 0.9 1.8 23.2 1070 500 D-12 645

50 0.387 1.0 1.8 26.3 1240 500 D-12 73070 0.268 1.1 1.8 29.9 1700 500 D-12 96095 0.193 1.1 1.9 33.9 2280 500 D-16 1350

120 0.153 1.2 2.0 37.5 2830 500 D-18 1660150 0.124 1.4 2.2 41.5 3510 500 D-18 2000185 0.0991 1.6 2.3 45.7 4280 500 D-19 2460

240 0.0754 1.7 2.5 51.5 5520 250 D-18 1620300 0.0601 1.8 2.6 56.1 6810 250 D-18 1940400 0.0470 2.0 2.9 63.3 8770 250 D-18 2430

NominalArea of

Conductor

Sqmm

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof

Insulation

mm

Thicknessof

Outer Sheath

mm

Approx.Overall

Diameter

mm

Approx.CableWeight

Kg/km

StandardPackingLength

Metre ± 10%

DrumSize

Approx.GrossWeight

KG

600/1000 V -TWO CORE

COPPER CONDUCTOR XLPE INSULATEDPVC SHEATHED CABLES

(Cu/XLPE/PVC)

*Circular solid Conductor (Class 1).All other circular stranded or circular stranded compacted (Class 2).Cables conform generally to BS 5467 - 1997 and IEC 502 - 1994

40C l i c k H e r e t o

N E X T P A G E

Page 40: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

1.5* 12.1 0.7 0.8 0.9 1.3 12.8 305 1000 D-10 3651.5 12.1 0.7 0.8 0.9 1.3 13.2 325 1000 D-10 3852.5* 7.41 0.7 0.8 0.9 1.4 13.8 360 1000 D-10 4202.5 7.41 0.7 0.8 0.9 1.4 14.2 375 1000 D-10 435

4 4.61 0.7 0.8 0.9 1.4 15.2 440 1000 D-11 5406 3.08 0.7 0.8 0.9 1.4 16.4 520 1000 D-11 620

10 1.83 0.7 0.8 0.9 1.5 18.0 670 1000 D-12 780

16 1.15 0.7 0.8 1.25 1.5 20.9 965 1000 D-12 108025 0.727 0.9 0.8 1.25 1.6 24.3 1310 1000 D-14 146035 0.524 0.9 1.0 1.6 1.7 27.8 1810 1000 D-18 2050

50 0.387 1.0 1.0 1.6 1.8 30.9 2070 500 D-14 119070 0.268 1.1 1.0 1.6 1.9 34.7 2650 500 D-16 154095 0.193 1.1 1.2 2.0 2.0 39.9 3640 500 D-18 2060

120 0.153 1.2 1.2 2.0 2.1 43.5 4330 500 D-18 2410150 0.124 1.4 1.2 2.0 2.2 47.3 5140 500 D-19 2890185 0.0991 1.6 1.4 2.5 2.4 53.1 6570 250 D-18 1890

240 0.0754 1.7 1.4 2.5 2.5 58.7 8050 250 D-18 2260300 0.0601 1.8 1.6 2.5 2.6 63.7 9610 250 D-18 2650400 0.0470 2.0 1.6 2.5 2.8 70.7 11900 250 D-21 3400

NominalArea of

Conductor

Sqmm

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof

Insulation

mm

Thickness ofExtrudedBedding

mm

Diameter ofArmour

Wire

mm

Thicknessof

Outer Sheath

mm

Approx.Overall

Diameter

mm

Approx.CableWeight

Kg/km

StandardPackingLength

Metre ± 10%

DrumSize

Approx.GrossWeight

KG

600/1000 V -TWO CORE

COPPER CONDUCTORXLPE INSULATED STEEL WIRE ARMOUREDPVC SHEATHED CABLES

(Cu/XLPE/PVC/SWA/PVC)

* Circular solid conductor (Class 1).All other conductors circular stranded or circular stranded compacted (Class 2).Cables conform to BS 5467 - 1997 and generally to IEC 502 - 1994.

41C l i c k H e r e t o

N E X T P A G E

Page 41: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

1.5* 12.1 0.7 1.8 11.3 170 1000 D-9 2301.5 12.1 0.7 1.8 11.7 175 1000 D-9 2352.5* 7.41 0.7 1.8 12.2 210 1000 D-9 2702.5 7.41 0.7 1.8 12.6 220 1000 D-9 280

4 4.61 0.7 1.8 13.7 280 1000 D-10 3406 3.08 0.7 1.8 15.0 360 1000 D-10 420

10 1.83 0.7 1.8 16.5 500 1000 D-11 600

16 1.15 0.7 1.8 18.9 705 1000 D-12 81525 0.727 0.9 1.8 19.9 955 500 D-10 54035 0.524 0.9 1.8 22.3 1250 500 D-11 725

50 0.387 1.0 1.8 25.5 1610 500 D-12 91570 0.268 1.1 1.9 28.2 2230 500 D-12 123095 0.193 1.1 2.0 32.2 3000 500 D-16 1710

120 0.153 1.2 2.1 35.8 3750 500 D-18 2120150 0.124 1.4 2.2 39.0 4640 500 D-18 2560185 0.0991 1.6 2.4 43.6 5730 250 D-14 1580

240 0.0754 1.7 2.6 49.6 7360 250 D-16 2050300 0.0601 1.8 2.7 54.2 9190 250 D-18 2540400 0.0470 2.0 3.0 61.8 11850 250 D-18 3200

NominalArea of

Conductor

Sqmm

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof

Insulation

mm

Thicknessof

Outer Sheath

mm

Approx.Overall

Diameter

mm

Approx.CableWeight

Kg/km

StandardPackingLength

Metre ± 10%

DrumSize

Approx.GrossWeight

KG

*Circular solid conductor (Class 1).Conductors including 16 Sqmm circular stranded (Class 2).25 sqmm and above shaped stranded conductors (Class 2).Cables upto 10 sqmm conform to IEC 502 - 1994.All other cables conform Generally to BS 5467 - 1997 and IEC 502 - 1994

42

600/1000 V - THREE CORE

COPPER CONDUCTOR XLPE INSULATEDPVC SHEATHED CABLES

(Cu/XLPE/PVC)

C l i c k H e r e t oN E X T P A G E

Page 42: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

1.5* 12.1 0.7 0.8 - 0.9 1.3 13.3 - 330 - 1000 D-10 390 -1.5 12.1 0.7 0.8 - 0.9 1.3 13.7 - 350 - 1000 D-10 410 -2.5* 7.41 0.7 0.8 - 0.9 1.4 14.4 - 390 - 1000 D-10 450 -2.5 7.41 0.7 0.8 - 0.9 1.4 14.8 - 415 - 1000 D-10 475 -

4 4.61 0.7 0.8 - 0.9 1.4 15.9 - 490 - 1000 D-11 590 -6 3.08 0.7 0.8 - 0.9 1.4 17.2 - 580 - 1000 D-12 690 -

10 1.83 0.7 0.8 - 1.25 1.5 19.6 - 850 - 1000 D-12 960 -

16 1.15 0.7 0.8 - 1.25 1.6 22.2 - 1110 - 1000 D-14 1260 -25 0.727 0.9 1.0 0.8 1.6 1.7 24.3 23.2 1520 1420 500 D-11 870 81035 0.524 0.9 1.0 0.8 1.6 1.8 26.9 25.8 1910 1790 500 D-12 1065 1010

50 0.387 1.0 1.0 0.8 1.6 1.8 30.1 29.0 2400 2250 500 D-12 1350 123070 0.268 1.1 1.0 0.8 1.6 1.9 32.8 31.7 3100 2950 500 D-14 1700 163095 0.193 1.1 1.2 0.8 2.0 2.1 38.2 36.7 4310 4060 500 D-16 2400 2270

120 0.153 1.2 1.2 0.8 2.0 2.2 41.8 40.3 5170 4920 500 D-18 2830 2700150 0.124 1.4 1.4 0.8 2.5 2.3 46.4 44.5 6620 6290 500 D-18 3550 3390185 0.0991 1.6 1.4 0.8 2.5 2.4 50.8 48.9 7860 7510 250 D-18 2210 2090

240 0.0754 1.7 1.4 0.8 2.5 2.6 56.9 55.0 9810 9410 250 D-18 2690 2590300 0.0601 1.8 1.6 0.8 2.5 2.7 61.8 59.5 11910 11430 250 D-18 3220 3100400 0.0470 2.0 1.6 0.8 2.5 2.9 69.2 66.9 14910 14330 200 D-19 3300 3110

NominalArea of

Conductor

Sqmm

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof

Insulation

mm

Diameterof

ArmourWire

mm

Thicknessof

OuterSheath

mm

StandardPackingLength

Metre ± 10%

DrumSize

Thickness ofBedding

mm

Approx.Overall Dia.

mm

Approx.Cable Weight

Kg/km

Approx. GrossWeight

Kg

ExtrudedBedding

LappedBedding

ExtrudedBedding

LappedBedding

ExtrudedBedding

LappedBedding

ExtrudedBedding

LappedBeeding

* Circular solid conductor (Class 1).Conductors including 16 Sqmm circular stranded (Class 2).25 Sqmm and above shaped stranded conductors (Class 2).Cables conform to BS 5467 - 1997 and generally to IEC 502 - 1994.Drum size given above are for cables with extruded bedding.

600/1000 V - THREE CORE

COPPER CONDUCTORXLPE INSULATED STEEL WIRE ARMOUREDPVC SHEATHED CABLES

(Cu/XLPE/PVC/SWA/PVC and Cu/XLPE/SWA/PVC)

43C l i c k H e r e t o

N E X T P A G E

Page 43: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

1.5* 12.1 0.7 1.8 12.1 195 1000 D-9 2551.5 12.1 0.7 1.8 12.6 205 1000 D-9 2652.5* 7.41 0.7 1.8 13.1 245 1000 D-10 3052.5 7.41 0.7 1.8 13.6 260 1000 D-10 320

4 4.61 0.7 1.8 14.8 335 1000 D-10 3956 3.08 0.7 1.8 16.2 435 1000 D-11 535

10 1.83 0.7 1.8 17.9 615 1000 D-12 725

16 1.15 0.7 1.8 20.6 880 1000 D-12 99025 0.727 0.9 1.8 22.0 1220 500 D-10 67035 0.524 0.9 1.8 25.4 1620 500 D-12 920

50 0.387 1.0 1.8 28.3 2100 500 D-12 116070 0.268 1.1 2.0 32.1 2930 500 D-16 168095 0.193 1.1 2.1 36.3 3950 500 D-18 2220

120 0.153 1.2 2.2 39.7 4920 500 D-18 2700150 0.124 1.4 2.4 44.8 6150 500 D-18 3320185 0.0991 1.6 2.6 49.7 7600 250 D-16 2110

240 0.0754 1.7 2.8 54.8 9730 250 D-18 2670300 0.0601 1.8 3.0 60.6 12190 250 D-18 3290400 0.0470 2.0 3.2 67.8 15650 200 D-18 3370

500 0.0366 2.2 3.5 76.9 19600 200 D-19 4240

NominalArea of

Conductor

Sqmm

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof

Insulation

mm

Thicknessof

Outer Sheath

mm

Approx.Overall

Diameter

mm

Approx.CableWeight

Kg/km

StandardPackingLength

Metre ± 10%

DrumSize

Approx.GrossWeight

KG

*Circular solid conductor (Class 1).Conductors including 16 Sqmm circular stranded (Class 2).25 Sqmm and above shaped stranded conductors (Class 2).Cables upto and including 16 Sqmm conform to IEC 502 - 1994.From 16 Sqmm upto and including 400 Sqmm conform generally to BS 5467 - 1997500 sqmm conform to IEC 502 - 1994.

600/1000 V - FOUR CORE

COPPER CONDUCTOR XLPE INSULATEDPVC SHEATHED CABLES

(Cu/XLPE/PVC)

44C l i c k H e r e t o

N E X T P A G E

Page 44: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

1.5* 12.1 0.7 0.8 - 0.9 1.4 13.5 - 380 - 1000 D-10 440 -1.5 12.1 0.7 0.8 - 0.9 1.4 14.8 - 400 - 1000 D-10 460 -2.5* 7.41 0.7 0.8 - 0.9 1.4 14.5 - 450 - 1000 D-11 550 -2.5 7.41 0.7 0.8 - 0.9 1.4 15.8 - 470 - 1000 D-11 570 -

4 4.61 0.7 0.8 - 0.9 1.4 17.0 - 570 - 1000 D-11 670 -6 3.08 0.7 0.8 - 1.25 1.5 18.3 - 790 - 1000 D-12 900 -

10 1.83 0.7 0.8 - 1.25 1.5 21.0 - 1020 - 1000 D-12 1130 -

16 1.15 0.7 0.8 - 1.25 1.6 23.9 - 1350 - 1000 D-14 1500 -25 0.727 0.9 1.0 0.8 1.6 1.7 26.4 25.7 1850 1730 500 D-12 1040 97535 0.524 0.9 1.0 0.8 1.6 1.8 30.0 28.4 2360 2220 500 D-12 1290 1220

50 0.387 1.0 1.0 0.8 1.6 1.9 33.1 31.6 2970 2820 500 D-16 1700 156070 0.268 1.1 1.2 0.8 2.0 2.1 38.1 36.9 4190 3980 500 D-18 2340 223095 0.193 1.1 1.2 0.8 2.0 2.2 42.3 40.9 5370 5150 500 D-18 2930 2820

120 0.153 1.2 1.4 0.8 2.5 2.3 47.1 45.9 6910 6560 500 D-19 3780 3600150 0.124 1.4 1.4 0.8 2.5 2.4 52.0 50.2 8340 8000 500 D-19 4490 4320185 0.0991 1.6 1.4 0.8 2.5 2.6 56.9 55.4 9980 9610 250 D-18 2740 2640

240 0.0754 1.7 1.6 0.8 2.5 2.7 62.2 61.4 12400 11910 250 D-18 3340 3220300 0.0601 1.8 1.6 0.8 2.5 2.9 68.0 67.2 15130 14600 250 D-18 4020 3890400 0.0470 2.0 1.8 0.8 3.15 3.2 77.1 76.1 19850 19140 200 D-19 4290 4150

500 0.0366 2.2 1.8 0.8 3.15 3.8 86.8 85.5 24460 23920 200 D-21 5310 5200

NominalArea of

Conductor

Sqmm

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof

Insulation

mm

Diameterof

ArmourWire

mm

Thicknessof

OuterSheath

mm

StandardPackingLength

Metre ± 10%

DrumSize

Thickness ofBedding

mm

Approx.Overall Dia.

mm

Approx.Cable Weight

Kg/km

Approx. GrossWeight

Kg

ExtrudedBedding

LappedBedding

ExtrudedBedding

LappedBedding

ExtrudedBedding

LappedBedding

ExtrudedBedding

LappedBeeding

*Circular solid conductor (Class 1).Conductors including 16 Sqmm circular stranded (Class 2).25 Sqmm and above shaped stranded conductors (Class 2).Cables upto and inluding 400 Sqmm conform to BS 5467 - 1997500 Sqmm conforms to IEC 502 - 1994Drum size given above are for cables with extruded bedding

600/1000 V - FOUR CORE

COPPER CONDUCTORXLPE INSULATED STEEL WIRE ARMOUREDPVC SHEATHED CABLES

(Cu/XLPE/PVC/SWA/PVC and Cu/XLPE/SWA/PVC)

45C l i c k H e r e t o

N E X T P A G E

Page 45: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

25 1.20 0.9 1.0 0.8 1.6 1.8 26.6 25.5 1270 1170 500 D -12 745 69535 0.868 0.9 1.0 0.8 1.6 1.9 29.9 28.8 1540 1410 500 D -12 880 81550 0.641 1.0 1.0 0.8 1.6 2.0 33.3 32.2 1840 1720 500 D -16 1130 1070

70 0.443 1.1 1.2 0.8 2.0 2.2 38.3 36.8 2570 2390 500 D -18 1530 144095 0.320 1.1 1.2 0.8 2.0 2.3 42.3 40.8 3090 2860 500 D -18 1790 1670

120 0.253 1.2 1.4 0.8 2.5 2.5 47.5 45.6 4060 3750 500 D -19 2350 2200

150 0.206 1.4 1.4 0.8 2.5 2.6 50.6 48.7 4630 4300 500 D -19 2640 2470185 0.164 1.6 1.4 0.8 2.5 2.8 56.6 55.2 5490 5170 250 D -18 1610 1530240 0.125 1.7 1.6 0.8 2.5 3.0 63.0 60.7 6650 6200 250 D -18 1900 1790

300 0.100 1.8 1.6 0.8 2.5 3.2 68.6 66.3 7830 7300 250 D -19 2280 2150400 0.0778 2.0 1.8 0.8 3.15 3.5 77.7 75.0 10310 9660 200 D -19 2380 2250500 0.0605 2.2 1.8 0.8 3.15 3.8 86.8 84.1 12350 11620 200 D -21 2890 2740

NominalArea of

Conductor

Sqmm

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof

Insulation

mm

Diameterof

ArmourWire

mm

Thicknessof

OuterSheath

mm

StandardPackingLength

Metre ± 10%

DrumSize

Thickness ofBedding

mm

Approx.Overall Diameter

mm

Approx.Cable Weight

Kg/km

Approx. GrossWeight

Kg

ExtrudedBedding

LappedBedding

ExtrudedBedding

LappedBedding

ExtrudedBedding

LappedBedding

ExtrudedBedding

LappedBeeding

600/1000 V -FOUR CORE

ALUMINIUM CONDUCTORXLPE INSULATED STEEL WIRE ARMOUREDPVC SHEATHED CABLES

(AI/XLPE/PVC/SWA/PVC and AI/XLPE/SWA/PVC)

All conductors shaped stranded (Class 2).Cables conform to IEC 502 - 1994.Drum size given above are for cables with extruded bedding.

46C l i c k H e r e t o

N E X T P A G E

Page 46: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

25 16 0.727 1.15 0.9 0.7 1.8 22.0 1090 500 D-10 60535 16 0.524 1.15 0.9 0.7 1.8 25.4 1410 500 D-12 81550 25 0.387 0.727 1.0 0.9 1.8 28.3 1890 500 D-12 106070 35 0.268 0.524 1.1 0.9 1.9 31.8 2610 500 D-14 1460

95 50 0.193 0.387 1.1 1.0 2.0 36.1 3520 500 D-18 2000120 70 0.153 0.268 1.2 1.1 2.2 39.7 4480 500 D-18 2480150 70 0.124 0.268 1.4 1.1 2.3 44.6 5440 500 D-18 2960

185 95 0.0991 0.193 1.6 1.1 2.4 49.3 6760 250 D-16 1900240 120 0.0754 0.153 1.7 1.2 2.6 54.4 8631 250 D-18 2400300 150 0.0601 0.124 1.8 1.4 2.8 60.2 10810 250 D-18 2940

300 185 0.0601 0.0991 1.8 1.6 2.9 60.4 11120 250 D-18 3020400 185 0.0470 0.0991 2.0 1.6 3.1 67.6 13840 200 D-18 3010

Nominal Area ofConductor

Thicknessof OuterSheath

mm

Approx.CableWeight

Kg/km

StandardPackingLength

Metre ± 10%

Approx.Overall

Diameter

mm

DrumSize

Approx.GrossWeight

Kg

Thickness ofInsulation

Sqmm Ohm/Km mm

Phase NeutralPhase Neutral Phase Neutral

Maximum ConductorResistance at 20ºC

600/1000 V -FOUR CORE WITH REDUCED NEUTRAL

COPPER CONDUCTOR XLPE INSULATEDPVC SHEATHED CABLES

(Cu/XLPE/PVC)

All phase conductors 25 Sqmm and above shaped stranded (Class 2).All neutral conductors circular stranded (Class 2).Cables conform generally to BS - 5467 - 1997

47C l i c k H e r e t o

N E X T P A G E

Page 47: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

Nominal Areaof Conductor

Maximum ConductorResistance at 20ºC

Thicknessof Insulation

Thicknessof Bedding

Diameterof

ArmourWire

Thicknessof

OuterSheath

Approx.Overall Diameter

Approx. CableWeight

StandardPackingLength

DrumSize

Approx.Gross Weight

Phase Neutral Phase Neutral Phase Neutral Extruded Lapped ExtrudedBedding

LappedBedding

ExtrudedBedding

LappedBedding

ExtrudedBedding

LappedBedding

Sqmm Okh/km mm mm mm mm mm Kg/Km Metre±10% Kg

10 6 1.83 3.08 0.7 0.7 1.0 - 1.25 1.8 22.0 - 1043 - 1000 D-14 1190 -16 10 1.15 1.83 0.7 0.7 1.0 - 1.25 1.8 24.7 - 1360 - 1000 D-14 1510 -25 16 0.727 1.15 0.9 0.7 1.0 0.8 1.6 1.8 26.6 25.3 1780 1650 500 D-12 1000 935

35 16 0.524 1.15 0.9 0.7 1.0 0.8 1.6 1.8 30.0 28.9 2200 2070 500 D-12 1210 115050 25 0.387 0.727 1.0 0.9 1.0 0.8 1.6 1.9 33.1 32.0 2780 2640 500 D-16 1600 153070 35 0.268 0.524 1.1 0.9 1.2 0.8 2.0 2.0 37.8 36.3 3890 3680 500 D-18 2190 2080

95 50 0.193 0.387 1.1 1.0 1.2 0.8 2.0 2.1 42.1 40.6 4970 4740 500 D-18 2730 2610120 70 0.153 0.268 1.2 1.1 1.2 0.8 2.0 2.2 45.5 44.0 6020 5780 500 D-19 3330 3210150 70 0.124 0.268 1.4 1.1 1.4 0.8 2.5 2.4 52.0 50.1 7680 7340 500 D-19 4160 3990

185 95 0.0991 0.193 1.6 1.1 1.4 0.8 2.5 2.5 56.7 54.8 9220 8860 250 D-18 2550 2460240 120 0.0754 0.153 1.7 1.2 1.6 0.8 2.5 2.6 62.0 59.7 11390 10900 250 D-18 3090 2970300 150 0.0601 0.124 1.8 1.4 1.6 0.8 2.5 2.8 67.8 65.5 13840 13310 250 D-18 3700 3570

300* 185 0.0601 0.0991 1.8 1.6 - 0.8 2.5 2.8 - 65.9 - 13600 250 D-18 - 3660300 185 0.0601 0.0991 1.8 1.6 1.6 0.8 2.5 2.8 67.8 65.5 14120 13600 250 D-18 3770 3640400 185 0.0470 0.0991 2.0 1.6 1.6 0.8 2.5 3.0 75.0 72.7 17150 16620 250 D-19 3750 1640

600/1000 V -FOUR CORE WITH REDUCED NEUTRAL

COPPER CONDUCTORXLPE INSULATED STEEL WIRE ARMOUREDPVC SHEATHED CABLES

(Cu/XLPE/PVC/SWA/PVC and Cu/XLPE/SWA/PVC)

All phase conductors upto 16 Sqmm circular stranded (Class 2).All phase conductors 25 Sqmm and above shaped stranded (Class 2).All neutral conductors circular stranded (Class 2)10 Sqmm and 16 Sqmm cables conform to IEC 502 - 1994, * Cable as per MEW, Kuwait specification.All other cables conform to BS 5467 - 1997Drum size given above are for cables with extruded bedding.

48C l i c k H e r e t o

N E X T P A G E

Page 48: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

Nominal Areaof Conductor

Maximum ConductorResistance at 20ºC

Thicknessof Insulation

Thicknessof Bedding

Diameterof

ArmourWire

Thicknessof

OuterSheath

Approx.Overall Diameter

Approx. CableWeight

StandardPackingLength

DrumSize

Approx.Gross Weight

Phase Neutral Phase Neutral Phase Neutral Extruded Lapped ExtrudedBedding

LappedBedding

ExtrudedBedding

LappedBedding

ExtrudedBedding

LappedBedding

Sqmm Ohm/Km mm mm mm mm mm Kg/Km Metre±10% Kg

35 16 0.868 1.91 0.9 0.7 1.0 0.8 1.6 1.8 29.7 28.6 1480 1350 500 D-12 850 88550 25 0.641 1.20 1.0 0.9 1.0 0.8 1.6 1.9 33.1 32.0 1780 1640 500 D-16 1100 103070 35 0.443 0.868 1.1 0.9 1.2 0.8 2.0 2.1 38.0 36.5 2480 2270 500 D-18 1480 1380

95 50 0.320 0.641 1.1 1.0 1.2 0.8 2.0 2.2 42.1 40.6 2980 2750 500 D-18 1730 1620120 70 0.253 0.443 1.2 1.1 1.2 0.8 2.0 2.3 45.7 44.2 3460 3220 500 D-19 2050 1930150 70 0.206 0.443 1.4 1.1 1.4 0.8 2.5 2.5 50.4 48.5 4440 4100 500 D-19 2540 2370

185 95 0.164 0.320 1.6 1.1 1.4 0.8 2.5 2.7 56.4 54.5 5270 4910 500 D-21 3060 2880240 120 0.125 0.253 1.7 1.2 1.6 0.8 2.5 2.9 62.8 60.5 6370 5880 500 D-22 3660 3410300 150 0.100 0.206 1.8 1.4 1.6 0.8 2.5 3.0 68.2 65.9 7450 6920 300 D-20 2660 2430

300* 185 0.100 0.164 1.8 1.6 - 0.8 2.5 2.7 - 65.7 - 6970 300 D-19 - 2410300 185 0.100 0.164 1.8 1.6 1.6 0.8 2.5 3.1 68.4 66.1 7560 7030 250 D-18 2130 2000400 185 0.0778 0.164 2.0 1.6 1.6 0.8 3.15 3.3 76.9 74.6 9750 9110 250 D-19 2760 2600

600/1000 V - FOUR CORE WITH REDUCED NEUTRAL

ALUMINIUM CONDUCTORXLPE INSULATED STEEL WIRE ARMOUREDPVC SHEATHED CABLES

AI/XLPE/PVC/SWA/PVC and AI/XLPE/SWA/PVC)

All phase conductors shaped stranded (Class 2).All neutral conductors circular stranded (Class 2).Cables conform to IEC 502 - 1994, * Cable as per MEW, Kuwait specification.Drum size shown above are for cables with extruded bedding.

49C l i c k H e r e t o

N E X T P A G E

Page 49: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

Cable Details

Sqmm Metre±10%

2x16+1x10 16 10 1.15 1.83 0.7 0.7 1.8 18.9 660 1000 D-12 770

3x25+2x16 25 16 0.727 1.15 0.9 0.7 1.8 27.2 1510 1000 D-16 1720

3x35+2x16 35 16 0.524 1.15 0.9 0.7 1.8 30.2 1850 500 D-14 1080

Nominal Areaof Conductor

Maximum ConductorResistance at 20ºC

Thicknessof Insulation

Thicknessof

OuterSheath

Approx.Overall

Diameter

Approx.CableWeight

StandardPackingLength

DrumSize

Approx.GrossWeightPhase Neutral

& EarthPhase Neutral

& EarthPhase Neutral

& Earth

Ohm/Km mm mm mm Kg/Km Kg

Cable Details Nominal Areaof

Conductor

MaximumConductorResistance

at 20ºC

Thicknessof

Insulation

Thicknessof

Outer Sheath

Approx.Overall

Diameter

Approx.CableWeight

StandardPackingLength

DrumSize

Approx.GrossWeight

5x1.5* 1.5 12.1 0.7 1.8 13.0 225 1000 D-10 2855x1.5 1.5 12.1 0.7 1.8 13.5 235 1000 D-10 2955x2.5* 2.5 7.41 0.7 1.8 14.1 280 1000 D-10 3405x2.5 2.5 7.41 0.7 1.8 14.6 295 1000 D-10 355

5x4 4 4.61 0.7 1.8 15.9 390 1000 D-11 4905x6 6 3.08 0.7 1.8 17.6 505 1000 D-12 6155x10 10 0.83 0.7 1.8 19.5 740 1000 D-12 850

5x16 16 1.15 0.7 1.8 22.4 1060 500 D-11 6305x25 25 0.727 0.9 1.8 27.2 1650 500 D-12 9255x35 35 0.524 0.9 1.8 30.2 2170 500 D-14 1235

Sqmm Ohm/Km mm mm mm Kg/Km Metre±10% Kg

600/1000 V - MULTICORE CABLES FOR STREET LIGHTING

COPPER CONDUCTOR XLPE INSULATEDPVC SHEATHED CABLES

(CU/XLPE/PVC)

*Circular solid conductors ( Class 1).All other conductors circular stranded ( Class 2).Cables conform to IEC 502 - 1994.

50C l i c k H e r e t o

H O M E

Page 50: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

AUXILIARY CABLES,PILOT CABLES,

COAXIAL CABLESAND

DATA TRANSMISSION CABLES

C l i c k H e r e t oN E X T P A G E

Page 51: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

600/1000 V - AUXILIARY CABLES (CONTROL CABLES)

COPPER CONDUCTOR PVC INSULATEDPVC SHEATHED CABLES

(Cu/PVC/PVC): SIZE: 1.5 SQMM

52

All the Cables are insulated with PVC Type 5 Heat Resisting 85ºC compound and sheathed with PVC Type 9Heat Resisting compound suitable for Cables operating at a maximum conductor temperature upto 90ºC,which exceeds the requirements of BS 6346 - 1997Cables conform generally to BS 6346 - 1997 and IEC 502 - 1994Core identification by number printing on white cores.

2 12.1 0.6 1.8 10.2 10.6 140 150 1000 D-8 190 2003 12.1 0.6 1.8 10.6 11.0 160 170 1000 D-8 210 2204 12.1 0.6 1.8 11.3 11.7 190 195 1000 D-9 250 255

5 12.1 0.6 1.8 12.2 12.7 220 235 1000 D-9 280 2957 12.1 0.6 1.8 13.0 13.6 265 280 1000 D-10 325 3408 12.1 0.6 1.8 13.8 14.5 305 320 1000 D-10 365 380

12 12.1 0.6 1.8 16.2 17.1 405 430 1000 D-12 515 54019 12.1 0.6 1.8 18.6 19.6 570 600 500 D-10 345 36027 12.1 0.6 1.8 21.8 23.1 765 810 500 D-11 485 505

37 12.1 0.6 1.8 24.2 25.6 990 1040 500 D-12 605 63048 12.1 0.6 1.9 27.6 29.3 1260 1320 500 D-12 740 77061 12.1 0.6 2.0 30.2 32.0 1550 1630 500 D-14 925 965

91 12.1 0.6 2.2 36.2 38.4 2250 2360 500 D-18 1365 1420

Numberof

Cores

No.

StandardPackingLength

Metre ± 10%

DrumSize

ApproximateOverall Diameter

mm

Thicknessof

Insulation

mm

Thicknessof

OuterSheath

mm

SolidCondr.

MaximumConductorResistance

at 20ºC

Ohm/km

StrandedCondr.

ApproximateCable Weight

Kg/Km

SolidCondr.

StrandedCondr.

ApproximateGross Weight

Kg

SolidCondr.

StrandedCondr.

C l i c k H e r e t oN E X T P A G E

Page 52: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

Numberof

Cores

No.

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof

Insulation

mm

Thicknessof

ExtrudedBedding

mm

Dia. ofArmour

Wire

mm

Thicknessof

OuterSheath

mm

StandardPackingLength

Metre ± 10%

DrumSize

ApproximateOverall Diameter

mm

SolidCondr.

StrandedCondr.

ApproximateCable Weight

Kg/Km

SolidCondr.

StrandedCondr.

ApproximateGross Weight

Kg

SolidCondr.

StrandedCondr.

2** 12.1 0.6 0.8 0.9 1.3*/1.4 12.2 12.8 290 310 1000 D-9 350 3703** 12.1 0.6 0.8 0.9 1.4 12.8 13.3 325 340 1000 D-10 385 4004** 12.1 0.6 0.8 0.9 1.4 13.6 14.1 360 385 1000 D-10 420 445

5** 12.1 0.6 0.8 0.9 1.4 14.4 14.9 410 430 1000 D-10 470 4907 12.1 0.6 0.8 0.9 1.4 15.2 15.8 465 490 1000 D-11 565 5908** 12.1 0.6 0.8 0.9 1.4*/1.5 16.0 16.9 520 560 1000 D-11 620 660

12 12.1 0.6 0.8 1.25 1.5 19.3 20.2 765 710 500 D-10 445 46519 12.1 0.6 0.8 1.25 1.6 21.9 22.9 1000 1050 500 D-11 600 62527 12.1 0.6 1.0 1.6 1.7 26.4 27.7 1450 1530 500 D-12 835 875

37 12.1 0.6 1.0 1.6 1.8 29.0 30.4 1760 1860 500 D-14 1030 108048 12.1 0.6 1.0 1.6 1.8*/1.9 32.2 34.1 2120 2260 500 D-16 1270 134061** 12.1 0.6 1.2 2.0 2.0 36.2 38.0 2780 2940 500 D-18 1630 1710

91** 12.1 0.6 1.2 2.0 2.2 42.2 44.4 3700 3890 500 D-18 2090 2185

600/1000 V - AUXILIARY CABLES (CONTROL CABLES)

COPPER CONDUCTORPVC INSULATED STEEL WIRE ARMOUREDPVC SHEATHED CABLES

(Cu/PVC/PVC/SWA/PVC): SIZE: 1.5 SQMM

* Applicable for circular solid conductor.All the Cables are Insulated with PVC Type 5 Heat Resisting 85ºC comlpound and sheathed with PVC Type 9Heat Resisting compound suitable for Cables operating at a maximum conductor temperature upto 90ºC,which exceeds the requirements of BS 6346 - 1997** Cables conform generally to BS 6346 - 1997 and IEC 502 - 1994.All other Cables conform to BS 6346 - 1997Core identification by number printing on white cores.

53C l i c k H e r e t o

N E X T P A G E

Page 53: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

Numberof

Cores

No.

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof

Insulation

mm

Thicknessof

ExtrudedBedding

mm

Thicknessof

CopperTape

mm

Thicknessof

OuterSheath

mm

StandardPackingLength

Metre ± 10%

DrumSize

ApproximateOverall Diameter

mm

SolidCondr.

StrandedCondr.

ApproximateCable Weight

Kg/Km

SolidCondr.

StrandedCondr.

ApproximateGross Weight

Kg

SolidCondr.

StrandedCondr.

2 12.1 0.6 1.0 0.05 1.8 12.0 12.4 215 225 1000 D-9 275 2853 12.1 0.6 1.0 0.05 1.8 12.4 12.9 235 250 1000 D-9 295 3104 12.1 0.6 1.0 0.05 1.8 13.2 13.7 270 285 1000 D-10 330 345

5 12.1 0.6 1.0 0.05 1.8 14.0 14.5 310 325 1000 D-10 370 3857 12.1 0.6 1.0 0.05 1.8 14.8 15.4 360 375 1000 D-11 460 4758 12.1 0.6 1.0 0.05 1.8 15.6 16.3 405 430 1000 D-11 505 530

12 12.1 0.6 1.0 0.05 1.8 18.0 18.9 520 550 500 D-10 320 33519 12.1 0.6 1.0 0.05 1.8 20.4 21.4 705 740 500 D-10 415 43027 12.1 0.6 1.0 0.05 1.8 23.6 24.9 925 975 500 D-12 575 600

37 12.1 0.6 1.0 0.05 1.8 26.0 27.4 1160 1220 500 D-12 690 72048 12.1 0.6 1.0 0.05 1.9 29.4 31.1 1460 1530 500 D-14 880 91561 12.1 0.6 1.2 0.05 2.0 32.4 34.2 1800 1900 500 D-16 1110 1160

91 12.1 0.6 1.2 0.05 2.2 38.4 40.6 2540 2670 500 D-18 1510 1580

600/1000 V - AUXILIARY CABLES ( CONTROL CABLES)

COPPER CONDUCTORPVC INSULATED COPPER TAPE SCREENEDPVC SHEATHED CABLES

(Cu/PVC/PVC/CuT/PVC): SIZE: 1.5 SQMM

All the Cables are insulated with PVC Type 5 Heat Resisting 85ºC compoundand sheathed with PVC Type 9Heat Resisting compound suitable for Cables operating at a maximum conductor temperature upto 90ºC,which exceeds the requirements of BS 6346 - 1997Cables conform generally to BS 6346 - 1997 and IEC 502 - 1994Core identification by number printing on white cores.

54C l i c k H e r e t o

N E X T P A G E

Page 54: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

Numberof

Cores

No.

2 12.1 0.6 1.0 0.05 1.2 0.9 1.8 16.4 16.8 490 515 500 D-9 305 3203 12.1 0.6 1.0 0.05 1.2 0.9 1.8 16.8 17.3 525 550 500 D-9 325 3354 12.1 0.6 1.0 0.05 1.2 0.9 1.8 17.6 18.1 575 600 500 D-10 350 360

5 12.1 0.6 1.0 0.05 1.2 0.9 1.8 18.4 18.9 630 655 500 D-10 375 3907 12.1 0.6 1.0 0.05 1.2 1.25 1.8 19.9 20.5 795 840 500 D-10 460 4808 12.1 0.6 1.0 0.05 1.2 1.25 1.8 20.7 21.4 865 915 500 D-11 490 520

12 12.1 0.6 1.0 0.05 1.2 1.6 1.8 23.8 24.7 1170 1240 500 D-12 685 73019 12.1 0.6 1.0 0.05 1.2 1.6 1.8 26.2 27.2 1430 1510 500 D-12 825 86527 12.1 0.6 1.0 0.05 1.2 1.6 1.9 29.6 30.9 1780 1870 500 D-16 1000 1085

37 12.1 0.6 1.0 0.05 1.2 1.6 2.0 32.2 33.6 2110 2230 500 D-16 1270 132048 12.1 0.6 1.0 0.05 1.2 2.0 2.1 36.4 38.1 2750 2890 500 D-18 1620 168061 12.1 0.6 1.2 0.05 1.2 2.0 2.2 39.4 41.2 3220 3370 500 D-18 1850 1920

91 12.1 0.6 1.2 0.05 1.3 2.5 2.4 46.6 48.8 4600 4820 500 D-19 2620 2730

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof

Insulation

mm

Thicknessof

ExtrudedBedding

mm

Thicknessof

CopperTape

mm

Thicknessof

ExtrudedInner

Sheath

mm

Dia. ofArmour

Wire

mm

Thicknessof

OuterSheath

mm

DrumSize

ApproximateGross Weight

Kg

SolidCondr.

StrandedCondr.

ApproximateOverall Diameter

mm

SolidCondr.

StrandedCondr.

ApproximateCable Weight

Kg/Km

SolidCondr.

StrandedCondr.

600/1000 V - AUXILIARY CABLES (CONTROL CABLES)

COPPER CONDUCTOR PVC INSULATEDCOPPER TAPE SCREENEDSTEEL WIRE ARMOURED PVC SHEATHED CABLES

(Cu/PVC/PVC/CuT/PVC/SWA/PVC): SIZE: 1.5 SQMM

All the Cables are insulated with PVC Type 5 Heat Resisting 85ºC compound and sheathed with PVC Type 9 Heat Resisting conpoundsuitable for Cables operating at a maximum conductor temperature upto 90ºC, which exceeds the requirements of BS 6346 - 1997.Cables conform generally to BS 6346 - 1997 and IEC 502 - 1994.Core idenfication by number printing on white cores.

55

StandardPackingLength

Metre ± 10%

C l i c k H e r e t oN E X T P A G E

Page 55: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

2 7.41 0.7 1.8 11.4 11.8 185 190 1000 D-9 245 2503 7.41 0.7 1.8 11.8 12.3 210 225 1000 D-9 270 2854 7.41 0.7 1.8 12.7 13.3 250 265 1000 D-10 310 325

5 7.41 0.7 1.8 13.8 14.3 295 315 1000 D-10 355 3757 7.41 0.7 1.8 14.8 15.4 365 380 500 D-8 235 2408 7.41 0.7 1.8 15.8 16.5 420 445 500 D-9 270 285

12 7.41 0.7 1.8 18.7 19.6 565 595 500 D-10 345 36019 7.41 0.7 1.8 21.6 22.6 810 845 500 D-11 505 52527 7.41 0.7 1.8 25.5 26.8 1100 1150 500 D-12 660 685

37 7.41 0.7 1.9 28.6 30.0 1440 1510 500 D-12 830 86548 7.41 0.7 2.0 32.7 34.4 1830 1920 500 D-16 1130 117061 7.41 0.7 2.1 35.8 37.6 2270 2380 500 D-18 1380 1430

91 7.41 0.7 2.3 43.0 45.2 3300 3460 500 D-19 1970 2050

Numberof

Cores

No.

StandardPackingLength

Metre ± 10%

DrumSize

ApproximateOverall Diameter

mm

Thicknessof

Insulation

mm

Thicknessof

OuterSheath

mm

SolidCondr.

MaximumConductorResistance

at 20ºC

Ohm/km

StrandedCondr.

ApproximateCable Weight

Kg/Km

SolidCondr.

StrandedCondr.

ApproximateGross Weight

Kg

SolidCondr.

StrandedCondr.

600/1000 V - AUXILIARY CABLES ( CONTROL CABLES)

COPPER CONDUCTOR PVC INSULATEDPVC SHEATHED CABLES

(Cu/PVC/PVC) : SIZE: 2.5 SQMM

All the Cables are insulated with PVC Type 5 Heat Resisting 85ºC compound and sheathed with PVC Type 9Heat Resisting compound suitable for Cables Operating at a maximum conductor temperature upto 90ºC,which exceeds the requirements of BS 6346 - 1997.Cables generally conform to BS 6346 - 1997 and IEC 502 - 1994.Core identification by number printing on white cores.

56C l i c k H e r e t o

N E X T P A G E

Page 56: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

Numberof

Cores

No.

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof

Insulation

mm

Thicknessof

ExtrudedBedding

mm

Dia. ofArmour

Wire

mm

Thicknessof

OuterSheath

mm

StandardPackingLength

Metre ± 10%

DrumSize

ApproximateOverall Diameter

mm

SolidCondr.

StrandedCondr.

ApproximateCable Weight

Kg/Km

SolidCondr.

StrandedCondr.

ApproximateGross Weight

Kg

SolidCondr.

StrandedCondr.

2** 7.41 0.7 0.8 0.9 1.4 13.6 14.0 355 370 1000 D-10 415 4303** 7.41 0.7 0.8 0.9 1.4 14.1 14.6 395 415 1000 D-10 455 4754** 7.41 0.7 0.8 0.9 1.4 15.0 15.5 450 470 1000 D-11 550 570

5** 7.41 0.7 0.8 0.9 1.4*/1.5 16.0 16.7 515 545 1000 D-11 615 6457 7.41 0.7 0.8 0.9*/1.25 1.5 17.2 18.5 605 720 1000 D-12 715 8308** 7.41 0.7 0.8 1.25 1.5 18.9 19.6 770 815 1000 D-12 880 925

12 7.41 0.7 0.8 1.25 1.6 22.0 22.9 1000 1050 500 D-11 600 62519 7.41 0.7 1.0 1.6 1.7 26.2 27.2 1490 1550 500 D-12 855 88527 7.41 0.7 1.0 1.6 1.8 30.3 31.6 1920 2010 500 D-14 1110 1160

37 7.41 0.7 1.0 1.6 1.9 33.4 34.8 2350 2460 500 D-16 1390 144048 7.41 0.7 1.2 2.0 2.0*/2.1 38.7 40.6 3170 3330 500 D-18 1830 191061** 7.41 0.7 1.2 2.0 2.2 42.0 43.8 3740 3910 500 D-18 2110 2200

91** 7.41 0.7 1.4 2.5 2.5 50.8 53.0 5500 5790 500 D-19 3070 3220

600/1000 V - AUXILIARY CABLES (CONTROL CABLES)

COPPER CONDUCTORPVC INSULATED STEEL WIRE ARMOUREDPVC SHEATHED CABLES

(Cu/PVC/PVC/SWA/PVC): SIZE: 2.5 SQMM

* Applicable for circular solid conductor.All the Cables are insulated with PVC Type 5 Heat Resisting 85ºC compound and sheathed with PVC Type 9Heat Resisting compound suitable for Cables operating at a maximum conductor temperature upto 90o C,which exceeds the requirements of BS 6346 - 1997** Cables conform generally to BS 6346 - 1997 and IEC 502 - 1994.All other cables conform to BS 6346 - 1997Core identification by number printing on white cores.

57C l i c k H e r e t o

N E X T P A G E

Page 57: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

Numberof

Cores

No.

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof

Insulation

mm

Thicknessof

ExtrudedBedding

mm

Thicknessof

CopperTape

mm

Thicknessof

OuterSheath

mm

StandardPackingLength

Metre ± 10%

DrumSize

ApproximateOverall Diameter

mm

SolidCondr.

StrandedCondr.

ApproximateCable Weight

Kg/Km

SolidCondr.

StrandedCondr.

ApproximateGross Weight

Kg

SolidCondr.

StrandedCondr.

2 7.41 0.7 1.0 0.05 1.8 13.2 13.6 265 275 1000 D-10 325 3353 7.41 0.7 1.0 0.05 1.8 13.7 14.2 295 310 1000 D-10 355 3704 7.41 0.7 1.0 0.05 1.8 14.6 15.1 345 360 1000 D-11 445 460

5 7.41 0.7 1.0 0.05 1.8 15.6 16.1 395 415 1000 D-11 495 5157 7.41 0.7 1.0 0.05 1.8 16.6 17.2 470 495 1000 D-12 580 6058 7.41 0.7 1.0 0.05 1.8 17.6 18.3 535 565 500 D-10 330 345

12 7.41 0.7 1.0 0.05 1.8 20.5 21.4 700 735 500 D-10 410 43019 7.41 0.7 1.0 0.05 1.8 23.4 24.4 960 1010 500 D-12 590 61527 7.41 0.7 1.0 0.05 1.8 27.3 28.6 1280 1350 500 D-12 750 785

37 7.41 0.7 1.0 0.05 1.9 30.4 31.8 1650 1730 500 D-14 975 102048 7.41 0.7 1.2 0.05 2.0 34.9 36.6 2100 2210 500 D-18 1290 135061 7.41 0.7 1.2 0.05 2.1 38.0 39.8 2570 2690 500 D-18 1530 1590

91 7.41 0.7 1.4 0.05 2.3 45.6 47.8 3690 3870 500 D-19 2170 2260

600/1000 V - AUXILIARY CABLES (CONTROL CABLES)

COPPER CONDUCTORPVC INSULATED COPPER TAPE SCREENEDPVC SHEATHED CABLES

(Cu/PVC/PVC/CuT/PVC): SIZE: 2.5 SQMM

All the Cables are insulated with PVC Type 5 Heat Resisting 85ºC compound and sheathed with PVC Type 9Heat Resisting compound suitable for Cables operating at a maximum conductor temperature upto 90ºC,which exceeds the requirements of BS 6346 - 1997.Cables conform generally to BS 6346 - 1997 and IEC 502 - 1994.Core identification by number printing on white cores.

58C l i c k H e r e t o

N E X T P A G E

Page 58: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

Numberof

Cores

No.

2 7.41 0.7 1.0 0.05 1.2 0.9 1.8 17.6 18.0 565 585 500 D-9 345 3553 7.41 0.7 1.0 0.05 1.2 0.9 1.8 18.1 18.6 615 635 500 D-10 370 3804 7.41 0.7 1.0 0.05 1.2 0.9 1.8 19.0 19.5 675 705 500 D-10 400 415

5 7.41 0.7 1.0 0.05 1.2 1.25 1.8 20.7 21.2 860 890 500 D-10 490 5057 7.41 0.7 1.0 0.05 1.2 1.25 1.8 21.7 22.3 960 1000 500 D-11 580 6008 7.41 0.7 1.0 0.05 1.2 1.25 1.8 22.7 23.4 1060 1100 500 D-11 630 650

12 7.41 0.7 1.0 0.05 1.2 1.6 1.8 26.3 27.2 1440 1500 500 D-12 830 86019 7.41 0.7 1.0 0.05 1.2 1.6 1.8 29.2 30.2 1800 1870 500 D-14 1050 109027 7.41 0.7 1.0 0.05 1.2 1.6 2.0 33.5 34.8 2270 2390 500 D-16 1350 1410

37 7.41 0.7 1.0 0.05 1.2 2.0 2.1 37.4 38.8 2970 3110 500 D-18 1730 180048 7.41 0.7 1.2 0.05 1.2 2.0 2.2 41.9 43.6 3610 3800 500 D-18 2050 214061 7.41 0.7 1.2 0.05 1.2 2.0 2.3 45.0 46.8 4200 4410 500 D-19 2420 2530

91 7.41 0.7 1.4 0.05 1.4 2.5 2.6 54.2 56.4 6160 6430 500 D-21 3500 3640

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof

Insulation

mm

Thicknessof

ExtrudedBedding

mm

Thicknessof

CopperTape

mm

Thicknessof

ExtrudedInner

Sheath

mm

Dia. ofArmour

Wire

mm

Thicknessof

OuterSheath

mm

DrumSize

ApproximateGross Weight

Kg

SolidCondr.

StrandedCondr.

ApproximateOverall Diameter

mm

SolidCondr.

StrandedCondr.

ApproximateCable Weight

Kg/Km

SolidCondr.

StrandedCondr.

StandardPackingLength

Metre ± 10%

600/1000 V - AUXILIARY CABLES (CONTROL CABLES)

COPPER CONDUCTOR PVC INSULATEDCOPPER TAPE SCREENEDSTEEL WIRE ARMOURED PVC SHEATHED CABLES

(Cu/PVC/PVC/CuT/PVC/SWA/PVC): 2.5 SQMM

All the Cables are insulated with PVC Type 5 Heat Resisting 85ºC compound and sheathed with PVC Type 9Heat Resisting compound suitable for Cables operating at a maximum conductor temperature upto 90ºC,which exceeds the requirements of BS 6346 - 1997Cables conform generally to BS 6346 - 1997 IEC 502 - 1994.Core identification by number printing on white cores.

59C l i c k H e r e t o

N E X T P A G E

Page 59: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

2 4.61 0.8 1.8 13.2 255 1000 D-10 3153 4.61 0.8 1.8 13.9 300 1000 D-10 3604 4.61 0.8 1.8 15.0 360 1000 D-10 420

5 4.61 0.8 1.8 16.2 435 500 D-9 2807 4.61 0.8 1.8 17.5 535 500 D-9 3308 4.61 0.8 1.8 18.8 625 500 D-10 375

12 4.61 0.8 1.8 22.5 845 500 D-11 52019 4.61 0.8 1.8 26.1 1220 500 D-12 72027 4.61 0.8 2.0 31.5 1710 500 D-14 1010

37 4.61 0.8 2.1 35.3 2250 500 D-18 137048 4.61 0.8 2.3 40.7 2890 500 D-18 1690

Numberof

Cores

No.

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof

Insulation

mm

Thicknessof

OuterSheath

mm

Approx.Overall

Diameter

mm

Approx.CableWeight

Kg/km

StandardPackingLength

Metre ± 10%

DrumSize

Approx.GrossWeight

Kg

600/1000 V - AUXILIARY CABLES (CONTROL CABLES)

COPPER CONDUCTOR PVC INSULATEDPVC SHEATHED CABLES

(Cu/PVC/PVC): SIZE: 4 SQMM

All the Cables are insulated with PVC Type 5 Heat Resisting 85ºC compound and sheathed with PVC Type 9Heat Resisting compound suitable for Cables operating at a maximum conductor temperature upto 90ºC,which exceeds the requirements of BS 6346 - 1997.All conductors circular stranded.Cables generally conform to BS 6346 - 1997 and IEC 502 - 1994.Core identification by number printing on white cores.

60C l i c k H e r e t o

N E X T P A G E

Page 60: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

2* 4.61 0.8 0.8 0.9 1.4 15.4 460 1000 D-11 5603* 4.61 0.8 0.8 0.9 1.4 16.1 515 1000 D-11 6154* 4.61 0.8 0.8 1.25 1.5 18.1 700 1000 D-12 810

5* 4.61 0.8 0.8 1.25 1.5 19.3 790 500 D-10 4557 4.61 0.8 0.8 1.25 1.6 20.8 935 500 D-10 5308* 4.61 0.8 0.8 1.25 1.6 22.1 1060 500 D-11 630

12 4.61 0.8 1.0 1.6 1.7 27.1 1550 500 D-12 88519 4.61 0.8 1.0 1.6 1.8 30.9 2060 500 D-14 118027 4.61 0.8 1.2 2.0 2.0 37.5 2990 500 D-18 1740

37 4.61 0.8 1.2 2.0 2.1 41.3 3670 500 D-18 208048 4.61 0.8 1.2 2.0 2.2 46.5 4490 500 D-19 2570

Numberof

Cores

No.

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof

Insulation

mm

Thicknessof

ExtrudedBedding

mm

Diaof

ArmourWire

mm

Thicknessof

OuterSheath

mm

Approx.Overall

Diameter

mm

Approx.CableWeight

Kg/km

StandardPackingLength

Metre ± 10%

DrumSize

Approx.GrossWeight

Kg

600/1000 V - AUXILIARY CABLES ( CONTROL CABLES)

COPPER CONDUCTORPVC INSULATED STEEL WIRE ARMOUREDPVC SHEATHED CABLES

(Cu/PVC/PVC/SWA/PVC): SIZE: 4 SQMM

Al the Cables are insulated with PVC Type 5 Heat Resisting 85ºC compound and sheathed with PVC Type 9Heat Resisting compound suitable for Cables operating at a maximum conductor temperature upto 90ºC,which exceeds the requirements of BS 6346 - 1997All conductors circular stranded.* Cables generally conform to BS 6346 - 1997.All other cables conform to BS 6346 - 1997.Core identification by number printing on white cores.

61C l i c k H e r e t o

N E X T P A G E

Page 61: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

2 12.1 0.7 1.8 11.2 160 1000 D-9 2203 12.1 0.7 1.8 11.6 175 1000 D-9 2354 12.1 0.7 1.8 12.5 205 1000 D-9 265

5 12.1 0.7 1.8 13.5 240 1000 D-10 3007 12.1 0.7 1.8 14.5 285 1000 D-10 3458 12.1 0.7 1.8 15.5 325 1000 D-11 425

12 12.1 0.7 1.8 18.3 430 500 D-10 27519 12.1 0.7 1.8 21.1 595 500 D-10 36027 12.1 0.7 1.8 24.9 800 500 D-12 510

37 12.1 0.7 1.8 27.7 1020 500 D-12 62048 12.1 0.7 1.8 31.5 1280 500 D-14 79061 12.1 0.7 1.9 34.5 1580 500 D-16 1000

91 12.1 0.7 2.1 41.5 2280 500 D-18 1380

Numberof

Cores

No.

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof

Insulation

mm

Thicknessof

OuterSheath

mm

ApproximateOverall

Diameter

mm

ApproximateCableWeight

Kg/km

StandardPackingLength

Metre ± 10%

DrumSize

ApproximateGrossWeight

Kg

600/1000 V - AUXILIARY CABLES (CONTROL CABLES)

COPPER CONDUCTOR XLPE INSULATEDPVC SHEATHED CABLES

(Cu/XLPE/PVC): SIZE: 1.5 SQMM

Cables conform to IEC 502 - 1994 and generally to BS 5467 - 1997All conductors circular stranded. Cables with solid conductor available on request.Core identification by number printing on white cores.

62C l i c k H e r e t o

N E X T P A G E

Page 62: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

2* 12.1 0.7 0.8 0.9 1.3 13.2 325 1000 D-10 3853* 12.1 0.7 0.8 0.9 1.3 13.7 350 1000 D-10 4104* 12.1 0.7 0.8 0.9 1.4 14.8 400 1000 D-10 460

5* 12.1 0.7 0.8 0.9 1.4 15.7 450 1000 D-11 5507 12.1 0.7 0.8 0.9 1.4 16.7 510 1000 D-11 6108* 12.1 0.7 0.8 1.25 1.5 18.6 675 1000 D-12 785

12 12.1 0.7 0.8 1.25 1.5 21.4 845 500 D-10 48519 12.1 0.7 0.8 1.25 1.6 24.4 1080 500 D-12 65027 12.1 0.7 1.0 1.6 1.7 29.5 1590 500 D-12 905

37 12.1 0.7 1.0 1.6 1.8 32.5 1900 500 D-16 116048* 12.1 0.7 1.0 1.6 1.9 36.5 2300 500 D-18 139061* 12.1 0.7 1.2 2.0 2.1 40.9 3010 500 D-18 1750

91* 12.1 0.7 1.2 2.0 2.2 47.7 3970 500 D-19 2310

Numberof

Cores

No.

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof

Insulation

mm

Thicknessof

ExtrudedBedding

mm

Dia.of

ArmourWire

mm

Thicknessof

OuterSheath

mm

ApproximateOverall

Diameter

mm

ApproximateCableWeight

Kg/Km

StandardPackingLength

Metre ± 10%

DrumSize

ApproximateGrossWeight

Kg

600/1000 V - AUXILIARY CABLES (CONTROL CABLES)

COPPER CONDUCTORXLPE INSULATED STEEL WIRE ARMOUREDPVC SHEATHED CABLES

(Cu/XLPE/PVC/SWA/PVC): SIZE: 1.5 SQMM

* Cables conform generally to BS 5467 - 1997 and IEC 502 - 1994.All other cables conform to BS 5467 - 1997All conductors circular stranded. Cables with solid conductor available on request.Core idenfication by number printing on white cores.

63C l i c k H e r e t o

N E X T P A G E

Page 63: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

2 12.1 0.7 1.0 0.05 1.8 13.0 235 1000 D-9 2953 12.1 0.7 1.0 0.05 1.8 13.5 260 1000 D-10 3204 12.1 0.7 1.0 0.05 1.8 14.4 295 1000 D-10 355

5 12.1 0.7 1.0 0.05 1.8 15.3 335 1000 D-11 4357 12.1 0.7 1.0 0.05 1.8 16.3 385 1000 D-11 4858 12.1 0.7 1.0 0.05 1.8 17.3 435 1000 D-12 545

12 12.1 0.7 1.0 0.05 1.8 20.1 565 500 D-10 34519 12.1 0.7 1.0 0.05 1.8 22.9 750 500 D-11 47527 12.1 0.7 1.0 0.05 1.8 26.7 980 500 D-12 600

37 12.1 0.7 1.0 0.05 1.8 29.5 1220 500 D-12 72048 12.1 0.7 1.0 0.05 1.8 33.3 1510 500 D-16 96561 12.1 0.7 1.2 0.05 1.9 36.7 1870 500 D-18 1180

91 12.1 0.7 1.2 0.05 2.1 43.7 2620 500 D-18 1550

Numberof

Cores

No.

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof

Insulation

mm

Thicknessof

ExtrudedBedding

mm

Thicknessof

CopperTape

mm

Thicknessof

OuterSheath

mm

ApproximateOverall

Diameter

mm

ApproximateCableWeight

Kg/km

StandardPackingLength

Metre ± 10%

DrumSize

ApproximateGrossWeight

Kg

600/1000 V - AUXILIARY CABLES (CONTROL CABLES)

COPPER CONDUCTORXLPE INSULATED COPPER TAPE SCREENEDPVC SHEATHED CABLES

(Cu/XLPE/PVC/CuT/PVC) : SIZE: 1.5 SQMM

Cables conform to IEC 502 - 1994 and generally to BS 5467 - 1997All conductors circular stranded. Cables with solid conductor available on request.Core identification by number printing on white cores.

64C l i c k H e r e t o

N E X T P A G E

Page 64: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

2 12.1 0.7 1.0 0.05 1.2 0.9 1.8 17.4 540 500 D-9 3303 12.1 0.7 1.0 0.05 1.2 0.9 1.8 17.9 570 500 D-9 3454 12.1 0.7 1.0 0.05 1.2 0.9 1.8 18.8 625 500 D-10 375

5 12.1 0.7 1.0 0.05 1.2 0.9 1.8 19.7 685 500 D-10 4057 12.1 0.7 1.0 0.05 1.2 1.25 1.8 21.4 875 500 D-10 5008 12.1 0.7 1.0 0.05 1.2 1.25 1.8 22.4 950 500 D-11 575

12 12.1 0.7 1.0 0.05 1.2 1.25 1.8 25.2 1150 500 D-12 68519 12.1 0.7 1.0 0.05 1.2 1.6 1.8 28.7 1570 500 D-12 89527 12.1 0.7 1.0 0.05 1.2 1.6 1.8 32.5 1920 500 D-16 1170

37 12.1 0.7 1.0 0.05 1.2 1.6 1.9 35.5 2280 500 D-18 138048 12.1 0.7 1.0 0.05 1.2 2.0 2.1 40.5 3000 500 D-18 174061 12.1 0.7 1.2 0.05 1.2 2.0 2.1 43.7 3460 500 D-18 1970

91 12.1 0.7 1.2 0.05 1.2 2.0 2.3 50.7 4490 500 D-19 2570

Numberof

Cores

No.

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof

Insulation

mm

Thicknessof

ExtrudedBedding

mm

Thicknessof

CopperTape

mm

Thickness ofExtruded

InnerSheath

mm

Dia.of

ArmourWire

mm

Thicknessof

OuterSheath

mm

ApproximateOverall

Diameter

mm

ApproximateCableWeight

Kg/km

StandardPackingLength

Metre ± 10%

DrumSize

ApproximateGrossWeight

Kg

600/1000 V - AUXILIARY CABLES (CONTROL CABLES)

COPPER CONDUCTOR XLPE INSULATEDCOPPER TAPE SCREENEDSTEEL WIRE ARMOURED PVC SHEATHED CABLES

(Cu/XLPE/PVC/CuT/PVC/SWA/PVC) : SIZE:1.5 SQMM

Cables conform to IEC 502- 1994 and generally to BS 5467 - 1997All conductors circular stranded. Cables with solid conductor available on request.Core identification by number printing on white cores.

65C l i c k H e r e t o

N E X T P A G E

Page 65: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

2 7.41 0.7 1.8 12.0 190 1000 D-9 2503 7.41 0.7 1.8 12.5 220 1000 D-9 2804 7.41 0.7 1.8 13.5 255 1000 D-10 315

5 7.41 0.7 1.8 14.6 305 1000 D-10 3657 7.41 0.7 1.8 15.7 365 500 D-8 2358 7.41 0.7 1.8 16.8 420 500 D-9 270

12 7.41 0.7 1.8 20.0 565 500 D-10 34519 7.41 0.7 1.8 23.1 795 500 D-11 50027 7.41 0.7 1.8 27.4 1080 500 D-12 650

37 7.41 0.7 1.8 30.5 1390 500 D-14 84548 7.41 0.7 1.9 35.0 1770 500 D-16 110061 7.41 0.7 2.0 38.3 2190 500 D-18 1340

91 7.41 0.7 2.3 46.3 3190 500 D-19 1920

Numberof

Cores

No.

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof

Insulation

mm

Thicknessof

OuterSheath

mm

ApproximateOverall

Diameter

mm

ApproximateCableWeight

Kg/km

StandardPackingLength

Metre ± 10%

DrumSize

ApproximateGrossWeight

Kg

600/1000 V - AUXILIARY CABLES (CONTROL CABLES)

COPPER CONDUCTOR XLPE INSULATEDPVC SHEATHED CABLES

(Cu/XLPE/PVC) : SIZE: 2.5 SQMM

Cables conform to IEC 502 - 1994 and generally to BS 5467 -1997All conductors circular stranded. Cables with solid conductor available on request.Core identification by number printing on white cores.

66C l i c k H e r e t o

N E X T P A G E

Page 66: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

2* 7.41 0.7 0.8 0.9 1.4 14.2 375 1000 D-10 4353* 7.41 0.7 0.8 0.9 1.4 14.8 415 1000 D-10 4754* 7.41 0.7 0.8 0.9 1.4 15.8 465 1000 D-11 565

5* 7.41 0.7 0.8 0.9 1.4 16.8 530 1000 D-11 6307 7.41 0.7 0.8 0.9 1.4 17.9 615 1000 D-12 7258* 7.41 0.7 0.8 1.25 1.6 20.1 810 1000 D-12 920

12 7.41 0.7 0.8 1.25 1.6 23.3 1030 500 D-11 61519 7.41 0.7 1.0 1.6 1.7 27.7 1520 500 D-12 87027 7.41 0.7 1.0 1.6 1.8 32.2 1950 500 D-16 1190

37 7.41 0.7 1.0 1.6 1.8 35.3 2360 500 D-18 142048* 7.41 0.7 1.2 2.0 2.1 41.4 3230 500 D-18 186061* 7.41 0.7 1.2 2.0 2.2 44.7 3760 500 D-18 2120

91* 7.41 0.7 1.4 2.5 2.4 53.9 5540 500 D-21 3190

Numberof

Cores

No.

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof

Insulation

mm

Thicknessof

ExtrudedBedding

mm

Dia.of

ArmourWire

mm

Thicknessof

OuterSheath

mm

ApproximateOverall

Diameter

mm

ApproximateCableWeight

Kg/km

StandardPackingLength

Metre ± 10%

DrumSize

ApproximateGrossWeight

Kg

600/1000 V - AUXILIARY CABLES (CONTROL CABLES)

COPPER CONDUCTORXLPE INSULATED STEEL WIRE ARMOUREDPVC SHEATHED CABLES

(Cu/XLPE/PVC/SWA/PVC): SIZE: 2.5 SQMM

*Cables conform generally to BS 5467 - 1997 and IEC 502 - 1994.All other cables conform to BS 5467 -1997All conductors circular stranded. Cables with solid conductor available on request.Core identification by number printing on white core

67C l i c k H e r e t o

N E X T P A G E

Page 67: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

2 7.41 0.7 1.0 0.05 1.8 13.8 275 1000 D-10 3353 7.41 0.7 1.0 0.05 1.8 14.4 310 1000 D-11 4104 7.41 0.7 1.0 0.05 1.8 15.4 355 1000 D-11 455

5 7.41 0.7 1.0 0.05 1.8 16.4 410 500 D-9 2657 7.41 0.7 1.0 0.05 1.8 17.5 480 500 D-9 3008 7.41 0.7 1.0 0.05 1.8 18.6 540 500 D-10 330

12 7.41 0.7 1.0 0.05 1.8 21.8 710 500 D-10 41519 7.41 0.7 1.0 0.05 1.8 24.9 960 500 D-12 59027 7.41 0.7 1.0 0.05 1.8 29.2 1270 500 D-12 745

37 7.41 0.7 1.0 0.5 1.8 32.3 1610 500 D-16 102048 7.41 0.7 1.2 0.5 1.9 37.2 2060 500 D-18 127061 7.41 0.7 1.2 0.5 2.0 40.5 2500 500 D-18 1490

91 7.41 0.7 1.4 0.5 2.3 48.9 3620 500 D-19 2130

Cables conform to IEC 502 - 1994 and generally to BS 5467 - 1997.All conductors circular stranded. Cables with solid conductor available on request .Core identification by number printing on white cores.

Numberof

Cores

No.

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof

Insulation

mm

Thicknessof

ExtrudedBedding

mm

Thicknessof

CopperTape

mm

Thicknessof

OuterSheath

mm

ApproximateOverall

Diameter

mm

ApproximateCableWeight

Kg/km

StandardPackingLength

Metre ± 10%

DrumSize

ApproximateGrossWeight

Kg

600/1000 V - AUXILIARY CABLES (CONTROL CABLES)

COPPER CONDUCTORXLPE INSULATED COPPER TAPE SCREENEDPVC SHEATHED CABLES

(Cu/XLPE/PVC/CuT/PVC): SIZE: 2.5 SQMM

68C l i c k H e r e t o

N E X T P A G E

Page 68: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

2 7.41 0.7 1.0 0.05 1.2 0.9 1.8 18.2 595 500 D-10 3603 7.41 0.7 1.0 0.05 1.2 0.9 1.8 18.8 640 500 D-10 3804 7.41 0.7 1.0 0.05 1.2 0.9 1.8 19.8 705 500 D-10 415

5 7.41 0.7 1.0 0.05 1.2 1.25 1.8 21.5 895 500 D-10 5107 7.41 0.7 1.0 0.05 1.2 1.25 1.8 22.6 990 500 D-11 5958 7.41 0.7 1.0 0.05 1.2 1.25 1.8 23.7 1090 500 D-11 645

12 7.41 0.7 1.0 0.05 1.2 1.6 1.8 27.6 1490 500 D-12 85519 7.41 0.7 1.0 0.05 1.2 1.6 1.8 30.7 1840 500 D-14 107027 7.41 0.7 1.0 0.05 1.2 1.6 1.9 35.2 2330 500 D-18 1410

37 7.41 0.7 1.0 0.05 1.2 2.0 2.0 39.3 3020 500 D-18 175048 7.41 0.7 1.2 0.05 1.2 2.0 2.2 44.4 3700 500 D-18 209061 7.41 0.7 1.2 0.05 1.2 2.0 2.3 47.7 4270 500 D-19 2460

91 7.41 0.7 1.4 0.05 1.3 2.5 2.5 57.1 6180 500 D-22 3620

Numberof

Cores

No.

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof

Insulation

mm

Thicknessof

ExtrudedBedding

mm

Thicknessof

CopperTape

mm

Thickness ofExtruded

InnerSheath

mm

Dia.of

ArmourWire

mm

Thicknessof

OuterSheath

mm

ApproximateOverall

Diameter

mm

ApproximateCableWeight

Kg/km

StandardPackingLength

Metre ± 10%

DrumSize

ApproximateGrossWeight

Kg

600/1000 V - AUXILIARY CABLES ( CONTROL CABLES)

COPPER CONDUCTOR XLPE INSULATEDCOPPER TAPE SCREENEDSTEEL WIRE ARMOURED PVC SHEATHED CABLES

(Cu/XLPE/PVC/CuT/PVC/SWA/PVC): SIZE: .2.5 SQMM

Cables conform to IEC 502 -1994 and generally to BS 5467 - 1997All conductors circular stranded. Cables with solid conductors available on request.Core identification by number printing on white cores.

69C l i c k H e r e t o

N E X T P A G E

Page 69: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

2 4.61 0.7 1.8 13.0 240 1000 D-9 3003 4.61 0.7 1.8 13.7 280 1000 D-10 3404 4.61 0.7 1.8 14.8 335 1000 D-10 395

5 4.61 0.7 1.8 15.9 400 1000 D-11 5007 4.61 0.7 1.8 17.2 490 1000 D-11 5908 4.61 0.7 1.8 18.5 565 500 D-10 340

12 4.61 0.7 1.8 22.1 770 500 D-11 48519 4.61 0.7 1.8 25.6 1110 500 D-12 66527 4.61 0.7 1.8 30.5 1520 500 D-14 910

37 4.61 0.7 1.9 34.2 2000 500 D-16 121048 4.61 0.7 2.1 39.5 2500 500 D-18 1490

Numberof

Cores

No.

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof

Insulation

mm

Thicknessof

OuterSheath

mm

ApproximateOverall

Diameter

mm

ApproximateCableWeight

Kg/km

StandardPackingLength

Metre ± 10%

DrumSize

ApproximateGrossWeight

Kg

600/1000 V - AUXILIARY CABLES (CONTROL CABLES)

COPPER CONDUCTOR XLPE INSULATEDPVC SHEATHED CABLES

(Cu/XLPE/PVC) : SIZE : 4 SQMM

Cables conform to IEC 502 - 1994 and generally to BS 5467 - 1997All conductors circular stranded.Core identification by number printing on white cores.

70C l i c k H e r e t o

N E X T P A G E

Page 70: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

2* 4.61 0.7 0.8 0.9 1.4 15.2 440 1000 D-11 5403* 4.61 0.7 0.8 0.9 1.4 15.9 490 1000 D-11 5904* 4.61 0.7 0.8 0.9 1.4 17.0 570 1000 D-11 670

5* 4.61 0.7 0.8 1.25 1.5 19.0 755 500 D-10 4407 4.61 0.7 0.8 1.25 1.5 20.3 880 500 D-10 5008* 4.61 0.7 0.8 1.25 1.5 22.9 1130 500 D-11 665

12 4.61 0.7 1.0 1.6 1.6 26.5 1460 500 D-12 84019 4.61 0.7 1.0 1.6 1.7 30.2 1920 500 D-12 107027 4.61 0.7 1.0 1.6 1.9 35.5 2500 500 D-16 1460

37 4.61 0.7 1.2 2.0 2.0 40.4 3400 500 D-18 194048* 4.61 0.7 1.2 2.0 2.2 45.7 4180 500 D-19 2410

Numberof

Cores

No.

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof

Insulation

mm

Thicknessof

ExtrudedBedding

mm

Dia.of

ArmourWire

mm

Thicknessof

OuterSheath

mm

ApproximateOverall

Diameter

mm

ApproximateCableWeight

Kg/km

StandardPackingLength

Metre ± 10%

DrumSize

ApproximateGrossWeight

Kg

600/1000 V - AUXILIARY CABLES ( CONTROL CABLES)

COPPER CONDUCTORXLPE INSULATED STEEL WIRE ARMOUREDPVC SHEATHED CABLES

(Cu/XLPE/PVC/SWA/PVC) : SIZE: 4 SQMM

*Cable conform generally to BS 5467 - 1997 and IEC 502 - 1994All other cables conform to BS 5467 - 1997All conductors circular stranded.Core identification by number printing on white cores.

71C l i c k H e r e t o

N E X T P A G E

Page 71: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

TotalNumber

ofCores

No.

ToWithstandMaximumInducedVoltageLevel

KV

NominalArea

ofConductor

Sqmm

Numberof

Cores

No.

MaximumResistance

at 20ºC

Ohm/km

Numberof

Pairs

No.

NominalDiameter

ofWires

mm

Numberof

Pairs

No.

NominalDiameter

ofWires

mm

Thicknessof

Insulation(Min.)

mm

Thicknessof

ScreeningTape

mm

ThicknessofPE

Bedding

mm

ThicknessofPE

InnerSheath

mm

Diameterof

ArmourWire

mm

Thicknessof

OuterSheath(Min.)

mm

Approx.Overall

Diameter

mm

Approx.CableWeight

Kg/Km

StandardPackingLength

Metre ± 10%

DrumSize

Approx.GrossWeight

Kg

CONDUCTOR

2.5 6 7.41 1 1.78 2 1.7816 5 & 0.5 0.09 - 1.0 1.25 1.7 24.0 930 1000 D-14 1050

0.635 10 28.48 2 0.90 3 0.90

2.5 6 7.41 3 1.78 - -34 15 & 0.8 0.075 1.8 1.0 2.0 1.9 44.0 2900 750 D-22 2640

0.635 28 28.48 - - 14 0.90

PILOT CABLE

COPPER CONDUCTOR PE INSULATEDSTEEL WIRE ARMOURED PVC SHEATHED CABLES

All conductors circular solid (Class 1).In 16 core Pilot Cable polyster laminated aluminium screen is provided over pairs for Solkor protection and Telephone System.In 34 core Pilot Cable individual pairs for Solkor protection system and intertripping and interlocking system are screened withplain copper tape. Also an overall screen of plain copper tape is provided over PE bedding.Cables conform to MEW Kuwait and ESI 09-6 specification.

72

Screened Pair Unscreened Pair

C l i c k H e r e t oN E X T P A G E

Page 72: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

GULF CABLEREF. TYPE

CA 1 - 001 CA 2 - 001 CA 2 - 005 CA 2 - 006SAT - 100

Inner Conductor Type and Solid Plain Copper Solid Plain Copper Solid Plain Copper Solid Plain CopperDia. Over (mm) 0.4 0.65 0.955 1.03

Dielectric Type and Solid PE Solid PE Air-Spaced PE Air-Spaced PEDia. Over (mm) 2.6 3.8 4.65 4.65

ScreenType and Plain Cu Wire Braid Plain Cu Wire Braid Poly-AL Tape+ Poly-AL Tape+Dia. Over (mm) 3.0 4.2 Plain Cu Wire Braid Tinned Cu Wire Braid

5.1 5.3

Jacket Type and PVC PVC PVC PVCDia. Over(mm) 5.0 6.4 7.1 7.0

Colour of Jacket White White Black White

Characteristic Impedance 75 Ohm 75 Ohm 75 Ohm 75 Ohm±3 ±3 ±3 ±3

D.C. Resistance of Inner Conductor 145 57.0 25.5 21.5Ohm/Km. at 20ºC

Nominal Capacitance 70 73 56 55nF / Km

Screen Coverage 95% - 100% 100%

80 MHz dB / 100 M 13.5 8.8 5.7 5.3

100 MHz dB / 100M 15.1 9.9 6.4 6.0

120 MHz dB / 100M 16.6 10.9 7.0 6.6

200 MHz dB / 100M 21.6 14.2 9.2 8.6

400 MHz dB / 100M 30.9 20.5 13.3 12.5

600 MHz dB / 100M 38.2 25.4 16.6 15.6

800 MHz dB / 100M 44.5 29.7 19.5 18.3

1000 MHz dB / 100M 50.2 33.6 22.1 20.8

Standard Packing Length (M) 100 100 100 100

Weight Per Coil (Kg) 3.2 4.5 4.7 4.7

Equivalent Spec. / Type 2.5C - 2V 4.5C - 2V RG 6 / U SAT-100

ATTENUATION

COAXIAL CABLES FOR T.V / SATELLITE ANTENNA Etc.

73C l i c k H e r e t o

N E X T P A G E

Page 73: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

TYPE OF CABLE *UTP

Conductor Size Solid Plain Copper24 AWG

Type of Insulation Polypropylene

Thickness of Insulation (mm) 0.21

Type of Shield N.A.

Type of Jacket PVC - Grey (Type - 9)

Thickness of Jacket (mm) 0.6

Overall Diameter (mm) 5.3

Conductor Resistance 93.8Max.Ohm / Km at 20ºC

Mutual Capacitance Max. 5.6 nF / 100 M

Capacitance Unbalance Max. 330 pF / 100 M

Characteristic Impedance 100 ± 15Ohms

Attenuation Max. at 100 MHz 22 dB / 100 M

Cross Talk Min. at 100 MHz 32 dB / 100 M

Core Identification White / Blue, BlueWhite / Orange, OrangeWhite / Green, GreenWhite / Brown, Brown

* Tested at ETL Laboratory for Frequency upto 350 Mhz, which exceeds the requirements of TIA / ETA - 568 AAbove Cables with FIRE RETARDENT or LOW SMOKE ZERO HALOGEN Jacket available on request.

DATA TRANSMISSION CABLE

24 AWG - 4 PAIR UNSHIELDED TWISTED PAIR (UTP-CAT-5) (ENHANCED)

74C l i c k H e r e t o

H O M E

Page 74: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

MEDIUM VOLTAGE CABLES

C l i c k H e r e t oN E X T P A G E

Page 75: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

76

35 0.524 2.5 0.4 1.6 1.8 23.9 860 500 D-11 53050 0.387 2.5 0.4 1.6 1.8 25.0 1010 500 D-12 61570 0.268 2.5 0.4 1.6 1.8 26.6 1250 500 D-12 735

95 0.193 2.5 0.4 1.6 1.8 28.5 1560 500 D-12 890120 0.153 2.5 0.4 1.6 1.9 30.2 1840 500 D-14 1070150 0.124 2.5 0.4 1.6 1.9 31.6 2160 500 D-14 1230

185 0.0991 2.5 0.4 1.6 2.0 33.4 2530 500 D-16 1480240 0.0754 2.6 0.4 2.0 2.1 37.1 3240 500 D-18 1860300 0.0601 2.8 0.4 2.0 2.2 39.7 3900 500 D-18 2190

400 0.0470 3.0 0.4 2.0 2.3 43.2 4870 500 D-18 2680500 0.0366 3.2 0.4 2.5 2.4 47.8 6110 500 D-19 3380630 0.0283 3.2 0.4 2.5 2.5 51.8 7520 500 D-19 4080

NominalArea of

Conductor

Sqmm

MaximumConductorResistance

at 20ºC

Ohm/Km

Thicknessof XLPE

Insulation

mm

Thicknessof Bedding

(Semiconducting)Tape

mm

Dia ofArmour

Wire

mm

Thicknessof OuterSheath

mm

Approx.Overall

Diameter

mm

Approx.CableWeight

Kg/Km

StandardPackingLength

Metre ± 10%

DrumSize

Approx.GrossWeight

Kg

3.8 / 6.6 KV - SINGLE CORE(HIGHEST SYSTEM VOLTAGE = 7.2 KV)

COPPER CONDUCTOR XLPE INSULATEDALUMINIUM WIRE ARMOUREDPVC SHEATHED CABLES

(Cu/SC/XLPE/SC/AWA/PVC)

All conductors circular compacted.Equivalant voltage designation as per IEC: 60502 - 2 - 1997 : 3.6 / 6 KVCables conform to IEC 60502 - 2 - 1997

C l i c k H e r e t oN E X T P A G E

Page 76: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

77

35 0.524 2.5 0.4 2.0 2.3 43.9 3310 500 D-18 190050 0.387 2.5 0.4 2.5 2.4 47.5 4230 500 D-19 244070 0.268 2.5 0.6 2.5 2.5 51.1 5100 500 D-19 2870

95 0.193 2.5 0.6 2.5 2.7 56.2 6260 500 D-21 3550120 0.153 2.5 0.6 2.5 2.8 59.7 7240 500 D-22 4090150 0.124 2.5 0.6 2.5 2.9 62.9 8310 250 D-18 2320

185 0.0991 2.5 0.6 2.5 3.0 66.6 9570 250 D-18 2630240 0.0754 2.6 0.6 2.5 3.2 72.8 11650 250 D-21 3330300 0.0601 2.8 0.6 3.15 3.4 79.7 14740 250 D-23 4190

400 0.0470 3.0 0.6 3.15 3.7 87.4 18020 250 D-23 5010

NominalArea of

Conductor

Sqmm

MaximumConductorResistance

at 20ºC

Ohm/Km

Thicknessof XLPE

Insulation

mm

Thicknessof Bedding

(Semiconducting)Tape

mm

Dia ofArmour

Wire

mm

Thicknessof OuterSheath

mm

Approx.Overall

Diameter

mm

Approx.CableWeight

Kg/Km

StandardPackingLength

Metre ± 10%

DrumSize

Approx.GrossWeight

Kg

3.8 / 6.6 KV - THREE CORE(HIGHEST SYSTEM VOLTAGE - 7.2 KV)

COPPER CONDUCTOR XLPE INSULATEDSTEEL WIRE ARMOUREDPVC SHEATHED CABLES

(Cu/SC/XLPE/SC/SWA/PVC)

All conductors circular compacted.Equivalant voltage designation as per IEC 60502 - 2 - 1997 : 3.6 /6 KVCables conform to IEC 60502 - 2 -1997.

C l i c k H e r e t oN E X T P A G E

Page 77: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

78

35 0.524 3.4 0.4 1.6 1.8 26.0 950 500 D-12 58550 0.387 3.4 0.4 1.6 1.8 27.0 1110 500 D-12 66070 0.268 3.4 0.4 1.6 1.8 28.0 1340 500 D-12 780

95 0.193 3.4 0.4 1.6 1.9 30.5 1670 500 D-14 985120 0.153 3.4 0.4 1.6 1.9 32.0 1940 500 D-14 1120150 0.124 3.4 0.4 1.6 2.0 33.6 2280 500 D-16 1350

185 0.0991 3.4 0.4 2.0 2.0 36.0 2730 500 D-18 1600240 0.0754 3.4 0.4 2.0 2.1 39.0 3340 500 D-18 1910300 0.0601 3.4 0.4 2.0 2.2 40.9 3990 500 D-18 2240

400 0.0470 3.4 0.4 2.0 2.3 44.0 4930 500 D-18 2710500 0.0366 3.4 0.4 2.5 2.4 48.2 6150 500 D-19 3390630 0.0283 3.4 0.4 2.5 2.5 52.2 7560 500 D-19 4100

NominalArea of

Conductor

Sqmm

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof XLPE

Insulation

mm

Thicknessof Bedding

(Semiconducting)Tape

mm

Dia ofArmour

Wire

mm

Thicknessof OuterSheath

mm

Approx.Overall

Diameter

mm

Approx.CableWeight

Kg/Km

StandardPackingLength

Metre ± 10%

DrumSize

Approx.GrossWeight

Kg

All conductors circular compacted.Equivalant voltage designation as per IEC: 60502 - 2 - 1997 : 6/10 KVCables conform to IEC 60502 - 2 - 1997

6.35/11 KV - SINGLE CORE(HIGHEST SYSTEM VOLTAGE -12 KV)

COPPER CONDUCTOR XLPE INSULATEDALUMINIUM WIRE ARMOUREDPVC SHEATHED CABLES

(Cu/SC/XLPE/SC/AWA/PVC)

C l i c k H e r e t oN E X T P A G E

Page 78: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

35 0.524 3.4 0.075 1.2 1.6 1.8 27.3 1130 500 D-12 67550 0.387 3.4 0.075 1.2 1.6 1.8 28.4 1290 500 D-12 75570 0.268 3.4 0.075 1.2 1.6 1.9 30.2 1560 500 D-14 930

95 0.193 3.4 0.075 1.2 1.6 1.9 32.1 1880 500 D-16 1150120 0.153 3.4 0.075 1.2 1.6 2.0 33.8 2190 500 D-16 1330150 0.124 3.4 0.075 1.2 2.0 2.1 36.2 2620 500 D-18 1550

185 0.0991 3.4 0.075 1.2 2.0 2.1 37.8 3000 500 D-18 1740240 0.0754 3.4 0.075 1.2 2.0 2.2 40.5 3640 500 D-18 2060300 0.0601 3.4 0.075 1.2 2.0 2.2 42.5 4290 500 D-18 2390

400 0.0470 3.4 0.075 1.2 2.0 2.4 45.8 5270 500 D-19 2960500 0.0366 3.4 0.075 1.3 2.5 2.5 50.2 6550 500 D-19 3600630 0.0283 3.4 0.075 1.4 2.5 2.6 54.4 8020 500 D-21 4430

NominalArea of

Conductor

Sqmm

Approx.CableWeight

Kg/Km

StandardPackingLength

Metre ± 10%

Thicknessof XLPE

Insulation

mm

Thicknessof Copper

Tape

mm

Thicknessof Extruded

Bedding

mm

MaximumConductorResistance

at 20ºC

Ohm/Km

Dia ofArmour

Wire

mm

Thicknessof OuterSheath

mm

Approx.Overall

Diameter

mm

DrumSize

Approx.GrossWeight

Kg

6.35/11 KV - SINGLE CORE(HIGHEST SYSTEM VOLTAGE -12 KV)

COPPER CONDUCTOR XLPE INSULATEDCOPPER TAPE SCREENEDALUMINIUM WIRE ARMOUREDPVC SHEATHED CABLES

(Cu/SC/XLPE/SC/CuT/PVC/AWA/PVC)

All conductors circular compacted.Equivalant voltage designation as per IEC 60502 - 2 - 1997 : 6/10 KVCables conform to IEC 60502 - 2 - 1997.

79C l i c k H e r e t o

N E X T P A G E

Page 79: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

35 0.524 3.4 0.4 2.5 2.4 49.0 4060 500 D-19 235050 0.387 3.4 0.4 2.5 2.5 51.6 4640 500 D-19 264070 0.268 3.4 0.6 2.5 2.7 56.0 5630 500 D-21 3240

95 0.193 3.4 0.6 2.5 2.8 60.3 6720 500 D-22 3830120 0.153 3.4 0.6 2.5 2.9 63.8 7720 250 D-18 2170150 0.124 3.4 0.6 2.5 3.0 67.0 8800 250 D-18 2440

. 185 0.0991 3.4 0.6 2.5 3.1 70.7 10080 250 D-21 2940240 0.0754 3.4 0.6 3.15 3.3 77.9 12960 250 D-21 3660300 0.0601 3.4 0.6 3.15 3.5 82.5 15150 250 D-23 4290

400 0.0470 3.4 0.6 3.15 3.7 89.1 18270 250 D-23 5070

NominalArea of

Conductor

Sqmm

MaximumConductorResistance

at 20ºC

Ohm/Km

Thicknessof XLPE

Insulation

mm

Thicknessof Bedding

(Semiconducting)Tape

mm

Dia ofArmour

Wire

mm

Thicknessof OuterSheath

mm

Approx.Overall

Diameter

mm

Approx.CableWeight

Kg/Km

StandardPackingLength

Metre ± 10%

DrumSize

Approx.GrossWeight

Kg

All conductors circular compacted.Equivalant voltage designation as per IEC 60502 - 2 - 1997 : 6/10 KVCables conform to IEC :60502 - 2 - 1997

6.35/11 KV - THREE CORE(HIGHEST SYSTEM VOLTAGE - 12 KV)

COPPER CONDUCTOR XLPE INSULATEDSTEEL WIRE ARMOUREDPVC SHEATHED CABLES

(Cu /SC/XLPE/SC/SWA/PVC)

80C l i c k H e r e t o

N E X T P A G E

Page 80: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

35 0.524 3.4 0.075 1.3 2.5 2.5 52.0 4700 500 D-19 267050 0.387 3.4 0.075 1.4 2.5 2.6 54.8 5300 500 D-21 307070 0.268 3.4 0.075 1.4 2.5 2.7 58.5 6240 500 D-22 3590

95 0.193 3.4 0.075 1.5 2.5 2.9 63.2 7460 500 D-23 4230120 0.153 3.4 0.075 1.6 2.5 3.0 66.8 8530 500 D-23 4770150 0.124 3.4 0.075 1.6 2.5 3.1 70.0 9650 500 D-23 5330

185 0.0991 3.4 0.075 1.7 2.5 3.2 73.9 11040 250 D-21 3180240 0.0754 3.4 0.075 1.8 3.15 3.4 81.2 14060 250 D-23 4020300 0.0601 3.4 0.075 1.9 3.15 3.6 86.1 16340 250 D-23 4590

400 0.0470 3.4 0.075 2.0 3.15 3.8 93.0 19610 250 D-23 5400

NominalArea of

Conductor

Sqmm

Approx.CableWeight

Kg/Km

StandardPackingLength

Metre ± 10%

Thicknessof XLPE

Insulation

mm

Thicknessof Copper

Tape

mm

Thicknessof Extruded

Bedding

mm

MaximumConductorResistance

at 20ºC

Ohm/Km

Dia ofArmour

Wire

mm

Thicknessof OuterSheath

mm

Approx.Overall

Diameter

mm

DrumSize

Approx.GrossWeight

Kg

6.35/11 KV - THREE CORE(HIGHEST SYSTEM VOLTAGE - 12 KV)

COPPER CONDUCTOR XLPE INSULATEDCOPPER TAPE SCREENEDSTEEL WIRE ARMOUREDPVC SHEATHED CABLES

(Cu/SC/XLPE/SC/CuT/PVC/SWA/PVC)

All conductors circular compacted.Equivalant voltage designation as per IEC 60502 - 2 - 1997 : 6/10KVCables conform to IEC 60502 - 2 -1997

81C l i c k H e r e t o

N E X T P A G E

Page 81: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

35 0.868 3.4 0.4 2.5 2.4 49.0 3440 500 D-19 204050 0.641 3.4 0.4 2.5 2.5 51.6 3790 500 D-19 222070 0.443 3.4 0.6 2.5 2.7 56.5 4430 500 D-21 2640

95 0.320 3.4 0.6 2.5 2.8 60.6 5050 500 D-22 3000120 0.253 3.4 0.6 2.5 2.9 63.8 5550 500 D-23 3280150 0.206 3.4 0.6 2.5 3.0 67.0 6070 500 D-23 3540

185 0.164 3.4 0.6 2.5 3.1 70.9 6740 250 D-21 2110240 0.125 3.4 0.6 3.15 3.3 78.0 8590 250 D-21 2570300 0.100 3.4 0.6 3.15 3.5 82.5 9640 250 D-23 2910

400 0.0778 3.4 0.6 3.15 3.7 89.6 11160 250 D-23 3290

NominalArea of

Conductor

Sqmm

MaximumConductorResistance

at 20ºC

Ohm/Km

Thicknessof XLPE

Insulation

mm

Thicknessof Bedding

(Semiconducting)Tape

mm

Dia ofArmour

Wire

mm

Thicknessof OuterSheath

mm

Approx.Overall

Diameter

mm

Approx.CableWeight

Kg/Km

StandardPackingLength

Metre ± 10%

DrumSize

Approx.GrossWeight

Kg

All conductors circular compacted.Equivalant voltage designation as per IEC 60502 - 2 - 1997 : 6/10 KVCables conform to IEC 60502 - 2 - 1997.

6.35/11 KV - THREE CORE(HIGHEST SYSTEM VOLTAGE - 12KV)

ALUMINIUM CONDUCTOR XLPE INSULATEDSTEEL WIRE ARMOUREDPVC SHEATHED CABLES

(AI/SC/XLPE/SC/SWA/PVC)

82C l i c k H e r e t o

N E X T P A G E

Page 82: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

35 0.868 3.4 0.075 1.3 2.5 2.5 52.0 4090 500 D-19 237050 0.641 3.4 0.075 1.4 2.5 2.6 54.8 4450 500 D-21 265070 0.443 3.4 0.075 1.4 2.5 2.7 58.9 5080 500 D-22 3010

95 0.320 3.4 0.075 1.5 2.5 2.9 63.4 5750 500 D-23 3380120 0.253 3.4 0.075 1.6 2.5 3.0 66.8 6350 500 D-23 3680150 0.206 3.4 0.075 1.6 2.5 3.1 70.0 6920 500 D-23 3960

185 0.164 3.4 0.075 1.7 2.5 3.2 74.1 7700 500 D-23 4350240 0.125 3.4 0.075 1.8 3.15 3.4 81.4 9690 500 D-24 5450300 0.100 3.4 0.075 1.9 3.15 3.6 86.1 10830 500 D-25-S 6170

400 0.0778 3.4 0.075 2.0 3.15 3.8 93.4 12500 250 D-23 3630

NominalArea of

Conductor

Sqmm

Approx.CableWeight

Kg/Km

StandardPackingLength

Metre ± 10%

Thicknessof XLPE

Insulation

mm

Thicknessof Copper

Tape

mm

Thicknessof Extruded

Bedding

mm

MaximumConductorResistance

at 20ºC

Ohm/Km

Dia ofArmour

Wire

mm

Thicknessof OuterSheath

mm

Approx.Overall

Diameter

mm

DrumSize

Approx.GrossWeight

Kg

All conductors circular compacted.Equivalant voltage designation as per IEC 60502 - 2 - 1997 : 6/10 KVCables conform to IEC 60502 - 2 - 1997.

6.35/11 KV - THREE CORE(HIGHEST SYSTEM VOLTAGE - 12 KV)

ALUMINIUM CONDUCTOR XLPE INSULATEDCOPPER TAPE SCREENEDSTEEL WIRE ARMOUREDPVC SHEATHED CABLES

(AI/SC/XLPE/SC/CuT/PVC/SWA/PVC)

83C l i c k H e r e t o

N E X T P A G E

Page 83: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

35 0.524 4.5 0.4 1.6 1.8 27.9 1050 500 D-12 63550 0.387 4.5 0.4 1.6 1.8 29.0 1210 500 D-12 71570 0.268 4.5 0.4 1.6 1.9 30.8 1470 500 D-14 885

95 0.193 4.5 0.4 1.6 1.9 32.7 1780 500 D-16 1100120 0.153 4.5 0.4 2.0 2.0 35.2 2170 500 D-18 1330150 0.124 4.5 0.4 2.0 2.1 36.8 2510 500 D-18 1500

185 0.0991 4.5 0.4 2.0 2.1 38.4 2890 500 D-18 1680240 0.0754 4.5 0.4 2.0 2.2 41.1 3510 500 D-18 2000300 0.0601 4.5 0.4 2.0 2.3 43.3 4170 500 D-18 2330

400 0.0470 4.5 0.4 2.5 2.4 47.4 5240 500 D-19 2950500 0.0366 4.5 0.4 2.5 2.5 50.6 6350 500 D-19 3500630 0.0283 4.5 0.4 2.5 2.6 54.6 7780 500 D-21 4310

NominalArea of

Conductor

Sqmm

MaximumConductorResistance

at 20ºC

Ohm/Km

Thicknessof XLPE

Insulation

mm

Thicknessof Bedding

(Semiconducting)Tape

mm

Dia ofArmour

Wire

mm

Thicknessof OuterSheath

mm

Approx.Overall

Diameter

mm

Approx.CableWeight

Kg/Km

StandardPackingLength

Metre ± 10%

DrumSize

Approx.GrossWeight

Kg

All conductors circular compactedCables conform to IEC 60502 - 2 - 1997

84

8.7/15KV - SINGLE CORE(HIGHEST SYSTEM VOLTAGE - 17.5 KV)

COPPER CONDUCTOR XLPE INSULATEDALUMINIUM WIRE ARMOUREDPVC SHEATHED CABLES

(Cu/SC/XLPE/SC/AWA/PVC)

C l i c k H e r e t oN E X T P A G E

Page 84: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

35 0.524 4.5 0.075 1.8 23.7 835 500 D-12 52050 0.387 4.5 0.075 1.8 24.8 980 500 D-12 60070 0.268 4.5 0.075 1.8 26.4 1220 500 D-12 720

95 0.193 4.5 0.075 1.8 28.3 1520 500 D-12 870120 0.153 4.5 0.075 1.9 30.0 1800 500 D-12 1010150 0.124 4.5 0.075 1.9 31.4 2110 500 D-14 1210

185 0.0991 4.5 0.075 2.0 33.2 2480 500 D-16 1450240 0.0754 4.5 0.075 2.0 35.7 3070 500 D-18 1780300 0.0601 4.5 0.075 2.1 37.9 3700 500 D-18 2090

400 0.0470 4.5 0.075 2.2 41.0 4620 500 D-18 2550500 0.0366 4.5 0.075 2.3 44.2 5660 500 D-18 3070630 0.0283 4.5 0.075 2.4 48.2 7040 500 D-19 3840

NominalArea of

Conductor

Sqmm

MaximumConductorResistance

at 20ºC

Ohm/Km

Thicknessof XLPE

Insulation

mm

Thicknessof Copper

Tape

mm

Thicknessof OuterSheath

mm

Approx.Overall

Diameter

mm

Approx.CableWeight

Kg/Km

StandardPackingLength

Metre ± 10%

DrumSize

Approx.GrossWeight

Kg

8.7/15 KV - SINGLE CORE(HIGHEST SYSTEM VOLTAGE - 17.5 KV)COPPER CONDUCTOR XLPE INSULATEDCOPPER TAPE SCREENEDPVC SHEATHED CABLES

(Cu/SC/XLPE/SC/CuT/PVC)

All conductors circular compacted.Cables conform to IEC 60502 - 2- 1997.

85C l i c k H e r e t o

N E X T P A G E

Page 85: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

35 0.524 4.5 0.075 1.2 1.6 1.9 29.7 1270 500 D-12 74550 0.387 4.5 0.075 1.2 1.6 1.9 30.8 1430 500 D-14 86570 0.268 4.5 0.075 1.2 1.6 1.9 32.4 1700 500 D-16 1060

95 0.193 4.5 0.075 1.2 2.0 2.0 35.3 2130 500 D-18 1310120 0.153 4.5 0.075 1.2 2.0 2.1 37.0 2440 500 D-18 1460150 0.124 4.5 0.075 1.2 2.0 2.1 38.4 2780 500 D-18 1630

185 0.0991 4.5 0.075 1.2 2.0 2.2 40.2 3180 500 D-18 1830240 0.0754 4.5 0.075 1.2 2.0 2.3 42.9 3840 500 D-18 2160300 0.0601 4.5 0.075 1.2 2.0 2.3 44.9 4490 500 D-18 2490

400 0.0470 4.5 0.075 1.3 2.5 2.5 49.4 5660 500 D-19 3150500 0.0366 4.5 0.075 1.3 2.5 2.6 52.6 6770 500 D-19 3710630 0.0283 4.5 0.075 1.4 2.5 2.7 56.8 8280 500 D-21 4560

NominalArea of

Conductor

Sqmm

Approx.CableWeight

Kg/Km

StandardPackingLength

Metre ± 10%

Thicknessof XLPE

Insulation

mm

Thicknessof Copper

Tape

mm

Thicknessof Extruded

Bedding

mm

MaximumConductorResistance

at 20ºC

Ohm/Km

Dia ofArmour

Wire

mm

Thicknessof OuterSheath

mm

Approx.Overall

Diameter

mm

DrumSize

Approx.GrossWeight

Kg

8.7/15 KV - SINGLE CORE(HIGHEST SYSTEM VOLTAGE - 17.5 KV)

COPPER CONDUCTOR XLPE INSULATEDCOPPER TAPE SCREENEDALUMINIUM WIRE ARMOUREDPVC SHEATHED CABLES

(Cu/SC/XLPE/SC/CuT/PVC/AWA/PVC)

All the conductors circular compacted.Cables conform to IEC 60502 - 2 - 1997

86C l i c k H e r e t o

N E X T P A G E

Page 86: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

35 0.524 4.5 0.075 2.5 49.4 2760 500 D-19 170050 0.387 4.5 0.075 2.6 52.0 3250 500 D-19 195070 0.268 4.5 0.075 2.7 55.6 4030 500 D-21 2440

95 0.193 4.5 0.075 2.8 59.9 5000 500 D-22 2970120 0.153 4.5 0.075 2.9 63.4 5880 500 D-23 3440150 0.124 4.5 0.075 3.0 66.6 6880 500 D-23 3940

185 0.0991 4.5 0.075 3.1 70.2 8030 500 D-23 4520240 0.0754 4.5 0.075 3.3 76.0 9930 500 D-23 5470300 0.0601 4.5 0.075 3.4 80.6 11890 500 D-23 6450

400 0.0470 4.5 0.075 3.7 87.4 14800 250 D-23 4200

NominalArea of

Conductor

Sqmm

MaximumConductorResistance

at 20ºC

Ohm/Km

Thicknessof XLPE

Insulation

mm

Thicknessof Copper

Tape

mm

Thicknessof OuterSheath

mm

Approx.Overall

Diameter

mm

Approx.CableWeight

Kg/Km

StandardPackingLength

Metre ± 10%

DrumSize

Approx.GrossWeight

Kg

All conductors circular compacted.Cables conform to IEC 60502 - 2 - 1997.

87

8.7/15 KV - THREE CORE(HIGHEST SYSTEM VOLTAGE - 17.5 KV)

COPPER CONDUCTOR XLPE INSULATEDCOPPER TAPE SCREENEDPVC SHEATHED CABLES

(Cu/SC/XLPE/SC/CuT/PVC)

C l i c k H e r e t oN E X T P A G E

Page 87: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

35 0.524 4.5 0.075 1.4 2.5 2.7 57.4 5320 500 D-22 313050 0.387 4.5 0.075 1.5 2.5 2.8 60.2 5980 500 D-22 346070 0.268 4.5 0.075 1.5 2.5 2.9 63.8 6940 500 D-23 3870

95 0.193 4.5 0.075 1.6 2.5 3.0 68.3 8170 500 D-23 4590120 0.153 4.5 0.075 1.7 2.5 3.1 72.0 9270 500 D-23 5140150 0.124 4.5 0.075 1.7 2.5 3.2 75.2 10410 500 D-23 5710

185 0.0991 4.5 0.075 1.8 3.15 3.4 80.5 12630 500 D-23 6820240 0.0754 4.5 0.075 1.9 3.15 3.6 86.5 14930 500 D-25-S 8220300 0.0601 4.5 0.075 2.0 3.15 3.7 91.3 17230 500 D-25-S 9370

400 0.0470 4.5 0.075 2.1 3.15 4.0 98.3 20580 400 D-25-S 8980

NominalArea of

Conductor

Sqmm

Approx.CableWeight

Kg/km

StandardPackingLength

Metre ± 10%

Thicknessof XLPE

Insulation

mm

Thicknessof Copper

Tape

mm

Thicknessof Extruded

Bedding

mm

MaximumConductorResistance

at 20ºC

Ohm/km

Dia ofArmour

Wire

mm

Thicknessof OuterSheath

mm

Approx.Overall

Diameter

mm

DrumSize

Approx.GrossWeight

Kg

All conductors circular compacted.Cables conform to IEC 60502 - 2 - 1997

88

8.7/15 KV - THREE CORE(HIGHEST SYSTEM VOLTAGE - 17.5 KV)

COPPER CONDUCTOR XLPE INSULATEDCOPPER TAPE SCREENEDSTEEL WIRE ARMOUREDPVC SHEATHED CABLES

(Cu/SC/XLPE/SC/CuT/PVC/SWA/PVC)

C l i c k H e r e t oN E X T P A G E

Page 88: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

35 0.868 4.5 0.075 1.4 2.5 2.7 57.4 4710 500 D-19 268050 0.641 4.5 0.075 1.5 2.5 2.8 60.2 5130 500 D-22 304070 0.443 4.5 0.075 1.5 2.5 2.9 64.2 5740 500 D-23 3370

95 0.320 4.5 0.075 1.6 2.5 3.0 68.5 6460 500 D-23 3730120 0.253 4.5 0.075 1.7 2.5 3.1 72.0 7100 500 D-23 4050150 0.206 4.5 0.075 1.7 2.5 3.2 75.2 7680 500 D-23 4340

185 0.164 4.5 0.075 1.8 3.15 3.4 80.8 9370 500 D-23 5190240 0.125 4.5 0.075 1.9 3.15 3.6 86.8 10580 500 D-25-S 6040300 0.100 4.5 0.075 2.0 3.15 3.7 91.3 11720 500 D-25-S 2930

400 0.0778 4.5 0.075 2.1 3.15 4.0 98.8 13490 400 D-25-S 6150

NominalArea of

Conductor

Sqmm

Approx.CableWeight

Kg/km

StandardPackingLength

Metre ± 10%

Thicknessof XLPE

Insulation

mm

Thicknessof Copper

Tape

mm

Thicknessof Extruded

Bedding

mm

MaximumConductorResistance

at 20ºC

Ohm/km

Dia ofArmour

Wire

mm

Thicknessof OuterSheath

mm

Approx.Overall

Diameter

mm

DrumSize

Approx.GrossWeight

Kg

All conductors circular compacted.Cables conform to IEC 60502 - 2 - 1997.

89

8.7/15 KV - THREE CORE(HIGHEST SSYSTEM VOLTAGE - 17.5 KV)

ALUMINIUM CONDUCTOR XLPE INSULATEDCOPPER TAPE SCREENEDSTEEL WIRE ARMOUREDPVC SHEATHED CABLES

(AI/SC/XLPE/SC/CuT/PVC/SWA/PVC)

C l i c k H e r e t oN E X T P A G E

Page 89: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

35 0.524 5.5 0.075 1.8 25.7 920 500 D-12 57050 0.387 5.5 0.075 1.8 26.8 1070 500 D-12 64570 0.268 5.5 0.075 1.8 28.4 1310 500 D-12 765

95 0.193 5.5 0.075 1.9 30.5 1630 500 D-14 965120 0.153 5.5 0.075 1.9 32.0 1900 500 D-14 1100150 0.124 5.5 0.075 2.0 33.6 2240 500 D-16 1330

185 0.0991 5.5 0.075 2.0 35.2 2600 500 D-18 1540240 0.0754 5.5 0.075 2.1 37.9 3200 500 D-18 1840300 0.0601 5.5 0.075 2.2 40.1 3850 500 D-18 2170

400 0.0470 5.5 0.075 2.3 43.2 4770 500 D-18 2630500 0.0366 5.5 0.075 2.4 46.4 5830 500 D-19 3240

630 0.0283 5.5 0.075 2.5 50.4 7220 500 D-19 3930

NominalArea of

Conductor

Sqmm

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof XLPE

Insulation

mm

Thicknessof Copper

Tape

mm

Thicknessof OuterSheath

mm

Approx.Overall

Diameter

mm

Approx.CableWeight

Kg/km

StandardPackingLength

Metre ± 10%

DrumSize

Approx.GrossWeight

Kg

All conductors circular compacted.Equivalant voltage designation as per IEC 60502 - 2 - 1997 : 12/20 KVCables conform to IEC 60502 - 2 - 1997.

12.7/22 KV - SINGLE CORE(HIGHEST SYSTEM VOLTAGE - 24 KV)

COPPER CONDUCTOR XLPE INSULATEDCOPPER TAPE SCREENEDPVC SHEATHED CABLES

(Cu/SC/XLPE/SC/CuT/PVC)

90C l i c k H e r e t o

N E X T P A G E

Page 90: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

35 0.524 5.5 0.075 2.6 53.9 3100 500 D-19 187050 0.387 5.5 0.075 2.7 56.5 3610 500 D-21 213070 0.268 5.5 0.075 2.8 60.1 4410 500 D-22 2630

95 0.193 5.5 0.075 2.9 64.4 5400 500 D-23 3170120 0.153 5.5 0.075 3.0 67.9 6300 500 D-23 3650150 0.124 5.5 0.075 3.1 71.1 7320 500 D-23 4160

185 0.0991 5.5 0.075 3.3 75.0 8540 500 D-23 4770240 0.0754 5.5 0.075 3.4 80.6 10440 250 D-23 3110300 0.0601 5.5 0.075 3.6 85.3 12450 250 D-23 3610

400 0.0470 5.5 0.075 3.8 91.9 15370 200 D-23 3570

NominalArea of

Conductor

Sqmm

MaximumConductorResistance

at 20ºC

Ohm/km

Thicknessof XLPE

Insulation

mm

Thicknessof Copper

Tape

mm

Thicknessof OuterSheath

mm

Approx.Overall

Diameter

mm

Approx.CableWeight

Kg/km

StandardPackingLength

Metre ± 10%

DrumSize

Approx.GrossWeight

Kg

All conductors circular compacted.Equivalant voltage designation as per IEC 60502-2-1997 : 12/20 KVCables conform to IEC: 60502 - 2 - 1997

91

12.7/22 KV - THREE CORE(HIGHEST SYSTEM VOLTAGE - 24 KV)

COPPER CONDUCTOR XLPE INSULATEDCOPPER TAPE SCREENEDPVC SHEATHED CABLES

(Cu/SC/XLPE/SC/CuT/PVC)

C l i c k H e r e t oN E X T P A G E

Page 91: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

35 0.524 5.5 0.075 1.5 2.5 2.8 62.1 5920 500 D-23 346050 0.387 5.5 0.075 1.6 2.5 2.9 64.9 6600 500 D-23 380070 0.268 5.5 0.075 1.6 2.5 3.1 68.7 7610 500 D-23 4310

95 0.193 5.5 0.075 1.7 2.5 3.2 73.2 8870 500 D-23 4940120 0.153 5.5 0.075 1.7 3.15 3.3 78.0 10730 250 D-21 3100150 0.124 5.5 0.75 1.8 3.15 3.4 81.4 12000 250 D-23 3500

185 0.0991 5.5 0.075 1.9 3.15 3.6 85.5 13460 200 D-22 3160240 0.0754 5.5 0.075 2.0 3.15 3.7 91.3 15780 200 D-23 3660300 0.0601 5.5 0.075 2.0 3.15 3.9 96.0 18110 200 D-24 4220

400 0.0470 5.5 0.075 2.2 3.15 4.1 103.0 21500 200 D-24 4900

NominalArea of

Conductor

Sqmm

Approx.CableWeight

Kg/km

StandardPackingLength

Metre ± 10%

Thicknessof XLPE

Insulation

mm

Thicknessof Copper

Tape

mm

Thicknessof Extruded

Bedding

mm

MaximumConductorResistance

at 20ºC

Ohm/km

Dia ofArmour

Wire

mm

Thicknessof OuterSheath

mm

Approx.Overall

Diameter

mm

DrumSize

Approx.GrossWeight

Kg

All conductors circular compacted .Equivalant voltage designation as per IEC 60502-2-1977 : 12/20 KVCables conform to IEC: 60502 - 2 - 1997

92

12.7/22 KV - THREE CORE(HIGHEST SYSTEM VOLTAGE -24 KV)

COPPER CONDUCTOR XLPE INSULATEDCOPPER TAPE SCREENEDSTEEL WIRE ARMOUREDPVC SHEATHED CABLES

(Cu/SC/XLPE/SC/CuT/PVC/SWA/PVC)

C l i c k H e r e t oN E X T P A G E

Page 92: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

35 0.868 5.5 0.075 1.5 2.5 2.8 62.1 5300 500 D-23 315050 0.641 5.5 0.075 1.6 2.5 2.9 64.9 5740 500 D-23 337070 0.443 5.5 0.075 1.6 2.5 3.1 69.2 6400 500 D-23 3710

95 0.320 5.5 0.075 1.7 2.5 3.2 73.5 7170 500 D-23 4090120 0.253 5.5 0.075 1.7 3.15 3.3 78.0 8550 250 D-21 2560150 0.206 5.5 0.075 1.8 3.15 3.4 81.4 9260 250 D-23 2820

185 0.164 5.5 0.075 1.9 3.15 3.6 85.7 10130 200 D-22 2500240 0.125 5.5 0.075 2.0 3.15 3.7 91.5 11420 200 D-23 2780300 0.100 5.5 0.075 2.0 3.15 3.9 96.0 12590 200 D-23 3020

400 0.0778 5.5 0.075 2.2 3.15 4.1 103.5 14410 200 D-23 3380

NominalArea of

Conductor

Sqmm

Approx.CableWeight

Kg/km

StandardPackingLength

Metre ± 10%

Thicknessof XLPE

Insulation

mm

Thicknessof Copper

Tape

mm

Thicknessof Extruded

Bedding

mm

MaximumConductorResistance

at 20ºC

Ohm/km

Dia ofArmour

Wire

mm

Thicknessof OuterSheath

mm

Approx.Overall

Diameter

mm

DrumSize

Approx.GrossWeight

Kg

All conductors circular compacted.Equivalant voltage designation asx per IEC 60502-2-1997 : 12/20 KVCables conform to IEC 60502 - 2 - 1997.

93

12.7/22 KV - THREE CORE(HIGHEST SYSTEM VOLTAGE - 24 KV)

ALUMINIUM CONDUCTOR XLPE INSULATEDCOPPER TAPE SCREENEDSTEEL WIRE ARMOUREDPVC SHEATHED CABLES

(AI/SC/XLPE/SC/CuT/PVC/SWA/PVC)

C l i c k H e r e t oN E X T P A G E

Page 93: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

50 0.387 8.0 0.075 1.2 2.0 2.2 39.4 2050 500 D-18 127070 0.268 8.0 0.075 1.2 2.0 2.2 41.0 2330 500 D-18 141095 0.193 8.0 0.075 1.2 2.0 2.3 43.1 2710 500 D-18 1600

120 0.153 8.0 0.075 1.2 2.0 2.3 44.6 3020 500 D-18 1750150 0.124 8.0 0.075 1.3 2.5 2.4 47.4 3570 500 D-19 2110185 0.0991 8.0 0.075 1.3 2.5 2.5 49.2 3990 500 D-19 2320

240 0.0754 8.0 0.075 1.3 2.5 2.5 51.7 4670 500 D-19 2660300 0.0601 8.0 0.075 1.4 2.5 2.6 54.1 5410 500 D-21 3130400 0.0470 8.0 0.075 1.4 2.5 2.7 57.2 6430 500 D-22 3690

500 0.0366 8.0 0.075 1.5 2.5 2.8 60.6 7620 500 D-22 4280630 0.0283 8.0 0.075 1.6 2.5 2.9 64.8 8935 500 D-21 M 4890

NominalArea of

Conductor

Sqmm

Approx.CableWeight

Kg/km

StandardPackingLength

Metre ± 10%

Thicknessof XLPE

Insulation

mm

Thicknessof Copper

Tape

mm

Thicknessof Extruded

Bedding

mm

MaximumConductorResistance

at 20ºC

Ohm/km

Dia ofArmour

Wire

mm

Thicknessof OuterSheath

mm

Approx.Overall

Diameter

mm

DrumSize

Approx.GrossWeight

Kg

All conductors circular compacted.Equivalant voltage designation as per IEC: 502 - 1994 : 18/30 KVCables conform to IEC 502 - 1994

94

19/33 KV - SINGLE CORE(HIGHEST SYSTEM VIOLTAGE - 36 KV)

COPPER CONDUCTOR XLLPE INSULATEDCOPPER TAPE SCREENEDALUMINIUM WIRE ARMOUREDPVC SHEATHED CABLES

(Cu/SC/XLPE/SC /CuT/PVC/AWA/PVC)

C l i c k H e r e t oN E X T P A G E

Page 94: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

50 0.387 8.0 0.075 1.8 3.15 3.4 78.8 9230 500 D-23 512070 0.268 8.0 0.075 1.8 3.15 3.5 82.5 10310 500 D-24 576095 0.193 8.0 0.075 1.9 3.15 3.6 87.0 11640 500 D-25-S 6570

120 0.153 8.0 0.075 2.0 3.15 3.7 90.6 12850 250 D-23 3710150 0.124 8.0 0.075 2.0 3.15 3.8 93.8 14150 250 D-23 4040185 0.0991 8.0 0.075 2.1 3.15 4.0 97.9 15700 250 D-23 4430

240 0.0754 8.0 0.075 2.2 3.15 4.1 104.0 18120 250 D-25 5280300 0.0601 8.0 0.075 2.3 3.15 4.3 109.0 20570 200 D-25 4860

NominalArea of

Conductor

Sqmm

Approx.CableWeight

Kg/km

StandardPackingLength

Metre ± 10%

Thicknessof XLPE

Insulation

mm

Thicknessof Copper

Tape

mm

Thicknessof Extruded

Bedding

mm

MaximumConductorResistance

at 20ºC

Ohm/km

Dia ofArmour

Wire

mm

Thicknessof OuterSheath

mm

Approx.Overall

Diameter

mm

DrumSize

Approx.GrossWeight

Kg

All conductors circular compacted.Equivalent voltage designation as per IEC: 502 - 1994 18/30 kmCables conform to IEC 502 - 1994.

95

19/33 KV - THREE CORE(HIGHHEST SYSTEM VOLTAGE - 36 KV)COPPER CONDUCTOR XLPE INSULATEDCOPPER TAPE SCREENEDSTEEL WIRE ARMOUREDPVC SHEATHED CABLES(Cu/SC/XLPE/SC/CuT/PVC/SWA/PVC)

C l i c k H e r e t oN E X T P A G E

Page 95: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

50 0.641 8.0 0.075 1.8 3.15 3.4 78.8 8380 500 D-23 469070 0.443 8.0 0.075 1.8 3.15 3.5 82.9 9120 500 D-24 516095 0.320 8.0 0.075 1.9 3.15 3.6 87.2 10000 500 D-25-S 5750

120 0.253 8.0 0.075 2.0 3.15 3.7 90.6 10680 250 D-23 3170150 0206 8.0 0.075 2.0 3.15 3.8 93.8 11410 250 D-23 3350185 0.164 8.0 0.075 2.1 3.15 4.0 98.1 12370 250 D-23 3590

240 0.125 8.0 0.075 2.2 3.15 4.1 104.0 13760 250 D-25 4190300 0.100 8.0 0.075 2.3 3.15 4.3 109.0 15060 200 D-25 3760

NominalArea of

Conductor

Sqmm

Approx.CableWeight

Kg/km

StandardPackingLength

Metre ± 10%

Thicknessof XLPE

Insulation

mm

Thicknessof Copper

Tape

mm

Thicknessof Extruded

Bedding

mm

MaximumConductorResistance

at 20ºC

Ohm/km

Dia ofArmour

Wire

mm

Thicknessof OuterSheath

mm

Approx.Overall

Diameter

mm

DrumSize

Approx.GrossWeight

Kg

All conductors circular compacted.Equivalant voltage designation as per IEC: 502 - 1994: 18/30 KVCables conform to IEC 502 - 1994.

96

19/33 KV - THREE CORE(HIGHEST SYSTEM VOLTAGE - 36 KV)

ALUMINIUM CONDUCTOR, XLPE INSULATEDCOPPER TAPE SCREENEDSTEEL WIRE ARMOUREDPVC SHEATHED CABLES(AL/SC/XLPE/SC/CuT/PVC/SWA/PVC)

C l i c k H e r e t oH O M E

Page 96: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

OVERHEAD TRANSMISSIONCONDUCTORS

C l i c k H e r e t oN E X T P A G E

Page 97: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

98

10 7 1.35 4.05 1.829 89.82 91.62 3752 2000 D-6 23014 7 1.60 4.80 1.303 126.2 128.7 5267 2000 D-6 30516 3 2.65 5.70 1.106 148.3 151.3 6194 2000 D-7 35016 7 1.70 5.10 1.154 142.4 145.2 5946 2000 D-7 340

25 7 2.10 6.30 0.7563 217.3 221.6 9073 2000 D-8 49532 3 3.75 8.06 0.5520 296.9 302.8 12400 1000 D-7 35032 7 2.46 7.38 0.5497 298.2 304.2 12442 1000 D-7 35035 7 2.50 7.50 0.5337 308.0 314.2 12860 1000 D-7 360

50 7 3.00 9.00 0.3706 443.5 452.4 18520 1000 D-7 50050 19 1.80 9.00 0.3819 435.8 444.5 17700 1000 D-7 49070 7 3.55 10.65 0.2646 621.1 633.5 25930 1000 D-8 68570 19 2.10 10.50 0.2806 593.2 605.1 24090 1000 D-8 660

95 19 2.50 12.50 0.1980 840.7 857.5 34140 1000 D-11 960100 7 4.30 12.90 0.1810 911.2 929.4 36540 1000 D-11 1030120 19 2.80 14.00 0.1578 1055 1076 42830 1000 D-12 1190125 19 2.90 14.50 0.1471 1131 1154 45940 1000 D-12 1265

150 19 3.20 16.00 0.1208 1377 1405 55940 1000 D-12 1515150 37 2.25 15.75 0.1264 1334 1361 53880 1000 D-12 1475185 19 3.55 17.75 0.09815 1695 1729 68860 1000 D-14 1880185 37 2.50 17.50 0.1024 1647 1680 66490 1000 D-14 1830

NominalArea

Sqmm

Number ofWires in

Conductor

No

NominalDia of

Wires inConductor

mm

ApproxConductorDiameter

mm

ConductorResistance

at 20ºC(Max)

Ohm/Km

NominalWeight

Kg/Km

MaximumWeight

Kg/Km

BreakingLog

(Min)

N

StandardPackingLength

Metre ± 10%

DrumSize

Approx.GrossWeight

Kg

Conductors conform to BS 7884 - 1997

CONDUCTORS FOR OVERHEAD LINES

HARD DRAWN COPPER CONDUCTOR

(HDBC)

C l i c k H e r e t oN E X T P A G E

Page 98: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

99

NominalArea

Sqmm

14 7 1.60 4.80 1.303 5744 0.8 1.6 6.8 8.4 150 175 2000 D-11 400 450

16 3 2.65 5.69 1.106 6590 0.8 1.6 7.7 9.3 170 200 2000 D-12 450 51032 3 3.75 8.05 0.5520 12710 0.8 1.6 10.5 12.1 325 365 1000 D-9 390 430

35 7 2.50 7.50 0.5337 14097 0.8 1.6 9.9 11.5 345 385 1000 D-9 405 45070 7 3.55 10.65 0.2646 26880 0.8 1.6 13.5 14.7 675 720 1000 D-10 740 780

100 7 4.30 12.90 0.1810 37640 0.8 1.6 15.7 16.9 950 1005 1000 D-12 1060 1120

Numberof

Wires

No

NominalDia of

Wires inConductor

mm

ApproxConductorDiameter

mm

MaximumResistance

at 20ºC

Ohm/km

Approx.Breaking

Load

N

Type 8 Type 16

DrumSize

ApproximateGross Weight

Type 8 Type 16

Approx. OverallDiameter of

Covered Conductor

Approx. Weightof

Covered Conductor

Type 8

StandardPackingLength

Metre ± 10%

CONDUCTORS FOR OVERHEAD LINES

PVC COVERED STRANDED HARD-DRAWNCOPPER CONDUCTORS

(HDBC/PVC)

All conductors circular stranded.Colour of covering shall be Black for Type 8 and Green for Type 16.Conductors conform to BS 6485 - 1999

CONDUCTOR Min. Thicknessof

Covering

Type 8 Type 16 Type 16

mm mm Kg/Km Kg

C l i c k H e r e t oN E X T P A G E

Page 99: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

100

CODE

NominalAluminium

Area

Sqmm

Stranding:No. and Nominal

Diameter ofWires

No./mm

Approx.Overall

Diameter

mm

Calculated D.CResistance

at 20ºC (Max.)

Ohm/Km

Approx.Weight ofConductor

Kg/Km

BreakingLoad

KN

StandardPackingLength

Metre ± 10%

DrumSize

ApproximateGrossWeight

Kg

MIDGE 22 7/2.06 6.18 1.227 64 3.99 2000 D-7 175ANT 50 7/3.10 9.30 0.5419 145 8.28 2000 D-9 350FLY 60 7/3.40 10.20 0.4505 174 9.90 2000 D-9 410

WASP 100 7/4.39 13.17 0.2702 290 16.00 2000 D-11 680HORNET 150 19/3.25 16.25 0.1825 434 25.70 2000 D-14 1020CHAFER 200 19/3.78 18.90 0.1349 587 32.40 2000 D-16 1380

COCKROACH 250 19/4.22 21.10 0.1083 731 40.40 2000 D-18 1700BUTTERFLY 300 19/4.65 23.25 0.08916 888 48.75 2000 D-18 2020CENTIPEDE 400 37/3.78 26.46 0.06944 1145 63.10 2000 D-19 2610

AAC conforfm to BS 215 ( Part !) 1970 ( 1985).

CONDUCTORS FOR OVERHEAD LINES

ALL ALUMINIUM CONDUCTORS

(AAC)

C l i c k H e r e t oN E X T P A G E

Page 100: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

CODE

NominalAluminium

Area

Sqmm

No. andNominalDiameterof Wires

No./mm

Approx.Overall

Diameter

mm

Calculated D.CResistance

at 20ºC (Max.)

Ohm/Km

Approx.Weight ofConductor

Kg/Km

BreakingLoad

KN

StandardPackingLength

Metre ± 10%

DrumSize

ApproximateGrossWeight

Kg

APHIS 26.4 3/3.35 7.2 1.081 73 4.11 2000 D-7 190GNAT 26.8 7/2.21 6.6 1.068 73 4.59 2000 D-7 195WEEVIL 31.6 3/3.66 7.9 0.9082 86 4.87 2000 D-8 225

MOSQUITO 37.0 7/2.59 7.8 0.7731 101 6.05 2000 D-8 255LADYBIRD 42.8 7/2.79 8.4 0.6694 117 6.88 2000 D-9 295BLUE BOTTLE 73.7 7/3.66 11.0 0.3884 202 11.34 2000 D-10 465

EARWIG 78.5 7/3.78 11.4 0.3645 215 11.95 2000 D-11 530GR0SSHOPPER 84.1 7/3.91 11.7 0.3405 230 12.78 2000 D-11 560CLEGG 95.6 7/4.17 12.5 0.2994 262 14.54 2000 D-11 625

BEETLE 106.6 19/2.67 13.4 0.2699 293 17.42 2000 D-12 700CATERPILLER 186.0 19/3.53 17.7 0.1547 512 28.65 2000 D-14 1170SPIDER 236.9 19/3.99 20.0 0.1214 652 36.02 2000 D-16 1510

DRONE 373.3 37/3.58 25.1 0.07723 1029 57.47 2000 D-18 2300MAYBUG 486.9 37/4.09 28.6 0.05921 1342 74.04 2000 D-19 3000SCORPION 529.5 37/4.27 29.9 0.05445 1460 80.0 2000 D-21 3340

CONDUCTORS FOR OVERHEAD LINES

ALL ALUMINIUM CONDUCTORS

(AAC)

AAC conform to BS 215 (Part 1) - 1970 (1985).

101C l i c k H e r e t o

N E X T P A G E

Page 101: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

CODE

NominalAluminium

Area

Sqmm

No. andNominalDiameterof Wires

No./mm

Approx.Overall

Diameter

mm

Calculated D.CResistance

at 20ºC (Max.)

Ohm/Km

Approx.Weight ofConductor

Kg/Km

BreakingLoad

KN

StandardPackingLength

Metre ± 10%

DrumSize

ApproximateGrossWeight

Kg

PEACHBELL 13.29 7/1.55 4.7 2.1690 37 2.35 2000 D-6 115ROSE 21.16 7/1.96 5.9 1.3620 58 3.68 2000 D-7 160IRIS 33.61 7/2.47 7.4 0.8574 93 5.63 2000 D-8 240

PANSY 42.39 7//2.78 8.3 0.6801 117 6.84 2000 D-8 285POPPY 53.48 7/3.12 9.4 0.5390 147 8.30 2000 D-10 355ASTER 67.42 7/3.50 10.5 0.4276 186 10.46 2000 D-10 435

PHLOX 85.03 7/3.93 11.8 0.3390 234 12.66 2000 D-11 570VALERIAN 126.70 19/2.91 14.6 0.2275 349 20.05 2000 D-12 810LAUREL 135.20 19/3.01 15.1 0.2133 373 21.40 2000 D-12 860

PEONY 152.00 19/3.19 16.0 0.1896 419 23.58 2000 D-14 990TULIP 170.50 19/3.38 16.9 0.1692 470 26.46 2000 D-14 1090DAFFODIL 177.40 19/3.45 17.2 0.1625 489 27.52 2000 D-14 1130

CANNA 201 19/3.67 18.4 0.1432 556 30.64 2000 D-16 1320GOLDENTUFT 228 19/3.91 19.6 0.1264 628 33.96 2000 D-16 1470SYRINGA 242 37/2.88 20.2 0.1193 666 38.26 2000 D-16 1540

COSMOS 242 19/4.02 20.1 0.1193 666 36.00 2000 D-16 1540HYACINTH 253 37/2.95 20.7 0.1137 698 40.10 2000 D-16 1610ZINNIA 253 19/4.12 20.6 0.1137 698 37.74 2000 D-16 1610

DAHLIA 282 19/4.35 21.7 0.1023 777 42.00 2000 D-18 1790MISTLETOE 282 37/3.11 21.8 0.1023 777 43.76 2000 D-18 1790MEADOWSWEET 304 37/3.23 22.6 0.0948 838 47.18 2000 D-18 1920

ORCHID 323 37/3.33 23.3 0.0893 888 50.01 2000 D-18 2020HEUCHERA 329 37/3.37 23.6 0.0875 910 51.11 2000 D-18 2060FLAG 355 61/2.72 24.5 0.0813 978 57.27 2000 D-18 2200

VERBENA 355 37/3.49 24.5 0.0813 978 55.04 2000 D-18 2200NASTURTIUM 363 61/2.75 24.8 0.0795 1000 58.52 2000 D-18 2240VIOLET 363 37/3.53 24.7 0.0795 1000 56.27 2000 D-18 2240

AAC conform to ASTM B-231-81 Class AA & CSA C49 - 1975.

CONDUCTORS FOR OVERHEAD LINES

ALL ALUMINIUM CONDUCTORS

(AAC)

102C l i c k H e r e t o

N E X T P A G E

Page 102: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

CODE

NominalAluminium

Area

Sqmm

No. andNominalDiameterof Wires

No./mm

Approx.Overall

Diameter

mm

Calculated D.CResistance

at 20ºC (Max.)

Ohm/Km

Approx.Weight ofConductor

Kg/Km

BreakingLoad

KN

StandardPackingLength

Metre ± 10%

DrumSize

ApproximateGrossWeight

Kg

CATTAIL 380 61/2.82 25.3 0.0759 1048 57.79 2000 D-18 2340LILAC 403 61/2.90 26.1 0.0715 1111 63.77 2000 D-19 2540ARBUTUS 403 37/3.72 26.1 0.0715 1111 61.26 2000 D-19 2540

SNAPDRAGON 456 61/3.09 27.8 0.0632 1257 70.77 2000 D-19 2830COCKSCOMB 456 37/3.96 27.7 0.0632 1257 67.94 2000 D-19 2830GOLDENROD 483 61/3.18 28.6 0.0596 1333 75.02 2000 D-21 3090

MAGNOLIA 483 37/4.08 28.6 0.0596 1333 72.02 2000 D-21 3090CAMELLIA 507 61/3.25 29.3 0.0569 1397 78.64 2000 D-21 3210HAWKWEED 507 37/4.18 29.2 0.0569 1397 75.49 2000 D-21 3210

LARKSPUR 524 61/3.31 29.8 0.0550 1444 81.27 2000 D-21 3310BLUEBELL 524 37/4.24 29.7 0.0550 1444 78.02 2000 D-21 3310MARIGOLD 564 61/3.43 30.9‘ 0.0511 1555 87.52 2000 D-21 3580

HAWTHORN 604 61/3.55 32.0 0.0477 1665 93.77 2000 D-22 3800NARCISSUS 645 61/3.67 33.0 0.0467 1777 98.02 2000 D-23 4050COLUMBINE 685 61/3.78 34.0 0.0421 1888 104.15 2000 D-23 4280

CARNATION 725 61/3.89 35.0 0.0398 1999 108.02 1000 D-19 2320GLADIOLUS 766 61/4.00 36.0 0.0376 2110 114.02 1000 D-19 2430COREOPSIS 806 61/4.10 37.0 0.0358 2222 120.03 1000 D-19 2550

JESSAMINE 887 61/4.30 38.7 0.0325 2445 132.10 1000 D-21 2870

CONDUCTORS FOR OVERHEAD LINES

ALL ALUMINIUM CONDUCTORS

(AAC)

AAC conform to ASTM B- 231-81 Class AA & CSA C49 - 1975.

103C l i c k H e r e t o

N E X T P A G E

Page 103: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

104

ConductorArea

Sqmm

NominalAluminium

Area

Sqmm

No. andNominalDiameterof Wires

No./mm

Approx.Overall

Diameter

mm

Calculated D.CResistance

at 20ºC (Max.)

Ohm/Km

Approx.Weight ofConductor

Kg/Km

BreakingLoad

KN

StandardPackingLength

Metre ± 10%

DrumSize

ApproximateGrossWeight

Kg

16 15.89 7/1.70 5.1 1.8017 44 2.84 2000 D-7 13025 24.25 7/2.10 6.3 1.1806 67 4.17 2000 D-8 18035 34.36 7/2.50 7.5 0.8332 94 5.74 2000 D-8 240

50 49.48 7/3.00 9.0 0.5786 135 7.95 2000 D-9 33050 48.36 19/1.80 9.0 0.5948 133 8.44 2000 D-9 33070 65.82 19/2.10 10.5 0.4370 181 11.28 2000 D-10 425

95 93.27 19/2.50 12.5 0.3084 256 15.65 2000 D-12 625120 117.00 19/2.80 14.0 0.2459 322 18.74 2000 D-12 755150 147.10 37/2.25 15.7 0.1960 406 25.21 2000 D-14 965

185 181.60 37/2.50 17.5 0.1558 501 30.46 2000 D-16 1210240 242.50 61/2.25 20.2 0.1192 670 39.39 2000 D-18 1580300 299.40 61/2.50 22.5 0.09651 827 47.58 2000 D-18 1890

400 400.10 61/2.89 26.0 0.07222 1105 60.72 2000 D-19 2530500 499.80 61./3.23 29.1 0.05782 1381 74.56 2000 D-21 3180625 626.20 91/2.96 32.6 0.04625 1733 95.06 2000 D-23 3970

800 802.10 91/3.35 36.8 0.03611 2219 118.26 1000 D-21 26401000 999.10 91/3.74 41.1 0.02897 2766 145.63 1000 D-21 3190

AAC - Conform to DIN 48201.

CONDUCTORS FOR OVERHEAD LINES

ALL ALUMINIUM CONDUCTORS

(AAC)

C l i c k H e r e t oN E X T P A G E

Page 104: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

CODE

GOPHER 25 6/2.36 1/2.36 30.62 7.08 1.0930 106 9.61 3000 D-10 380WEASEL 30 6/2.59 1/2.59 36.88 7.77 0.9077 128 11.45 3000 D-10 440FERRET 40 6/3.00 1/3.00 49.48 9.00 0.6766 172 15.20 3000 D-10 580

RABBIT 50 6/3.35 1/3.35 61.70 10.05 0.5426 214 18.35 3000 D-12 750HORSE 70 12/2.79 7/2.79 116.20 13.95 0.3936 538 61.20 3000 D-14 1770DOG 100 6/4.72 7/1.57 118.50 14.15 0.2733 394 32.70 3000 D-16 1390

WOLF 150 30/2.59 7/2.59 194.90 18.13 0.1828 726 69.20 3000 D-18 2420DINGO 150 18/3.35 1/3.35 167.50 16.75 0.1815 506 35.70 3000 D-16 1730LYNX 175 30/2.79 7/2.79 226.20 19.53 0.1576 842 79.80 3000 D-18 2770

CARACAL 175 18/3.61 1/3.61 194.50 18.03 0.1563 587 41.10 3000 D-18 2000PANTHER 200 30/3.00 7/3.00 261.50 21.00 0.1363 974 92.25 3000 D-18 3160JAGUAR 200 18/3.86 1/3.86 222.30 19.30 0.1367 671 46.55 3000 D-18 2250

ZEBRA 400 54/3.18 7/3.18 484.50 28.62 0.0674 1621 131.90 2500 D-22 4530

NominalAluminium

Area

Sqmm

Stranding: No. and NominalDiameter of Wires

TotalSectional

Area

Sqmm

Approx.Overall

Diameter

mm

Calculated D.CResistance

at 20ºC (Max.)

Ohm/Km

Approx.Weight ofConductor

Kg/Km

BreakingLoad

KN

StandardPackingLength

Metre ± 10%

DrumSize

ApproximateGrossWeight

Kg

Aluminium Steel

No/mm

CONDUCTORS FOR OVERHEAD LINES

ALUMINIUM CONDUCTORSTEEL REINFORCED

(ACSR)

Conductors conform to BS 215 (Part 2) - 1970.

105C l i c k H e r e t o

N E X T P A G E

Page 105: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

CODE

MOLE 12.39 10.62 6/1.50 1/1.50 4.50 2.702 29 43 4.1 2000 D-6 130SQUIRREL 24.43 20.94 6/2.11 1/2.11 6.33 1.370 58 85 7.9 2000 D-8 220FOX 42.77 36.66 6/2.79 1/2.79 8.37 0.7827 101 149 13.2 2000 D-9 360

MINK 73.71 63.18 6/3.66 1/3.66 10.98 0.4541 173 255 21.8 2000 D-10 570SKUNK 100.50 63.48 12/2.59 7/2.59 12.95 0.4565 175 465 53.1 2000 D-12 1040BEAVER 87.82 74.82 6/3.99 1/3.99 11.97 0.3834 205 302 25.7 2000 D-11 705

RACCON 92.4 79.20 6/4.10 1/4.10 12.30 0.3623 217 320 27.2 2000 D-12 750OTTER 97.86 83.88 6/4.22 1/4.22 12.66 0.3421 230 339 28.7 2000 D-12 790HYENA 126.2 105.8 7/4.39 7/1.93 14.57 0.2712 290 450 40.9 2000 D-12 1010

COYOTE 152.2 132.1 26/2.54 7/1.91 15.89 0.2187 365 522 46.4 2000 D-14 1190COUGAR 137.5 130.3 18/3.05 1/3.05 15.25 0.2210 362 419 29.8 2000 D-14 990TIGER 161.7 131.1 30/2.36 7/2.36 16.52 0.2204 362 602 58.0 2000 D-14 1350

LION 294.2 238.5 30/3.18 7/3.18 22.26 0.1212 659 1095 100.6 2000 D-18 2430BEAR 325.6 264.0 30/3.35 7/3.35 23.45 0.1095 730 1213 111.1 2000 D-18 2670GOAT 400.0 324.3 30/3.71 7/3.71 25.97 0.08910 896 1489 135.7 2000 D-19 3300

SHEEP 461.4 374.1 30/3.99 7/3.99 27.93 0.07724 1034 1718 155.9 2000 D-19 3760ANTELOPE 421.5 373.1 54/2.97 7/2.97 26.73 0.07747 1032 1411 118.2 2000 D-19 3140BISON 431.3 381.8 54/3.00 7/3.00 27.00 0.07571 1056 1444 120.9 2000 D-19 3210

DEER 529.5 429.3 30/4.27 7/4.27 29.89 0.06731 1186 1971 178.5 2000 D-21 4360CAMEL 536.8 475.2 54/3.35 7/3.35 30.15 0.06083 1314 1797 145.7 2000 D-22 4060MOOSE 597.2 528.7 54/3.53 7/3.53 31.77 0.05468 1462 1999 161.1 2000 D-22 4470

CONDUCTORS FOR OVERHEAD LINES

ALUMINIUM CONDUCTORSTEEL REINFORCED

( ACSR)

Conductor Area No. & NominalDiameter of Wires

Approx.Overall

Diameter

mm

Calculated D.CResistance

at 20ºC (Max.)

Ohm/Km

Approx.Conductor Weight

BreakingLoad

KN

StandardPackingLength

Metre ± 10%

DrumSize

ApproximateGrossWeight

Kg

Total Aluminium Aluminium Steel Aluminium Total

Kg/KmSqmm No./mm

Conductors generally conform to BS 215 (Part 2) 1970.

106C l i c k H e r e t o

N E X T P A G E

Page 106: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

CODE

TURKEY 15.50 13.29 6/1.68 1/1.68 5.04 2.157 36 54 5.3 2000 D-6 150THRUSH 19.54 16.77 6/1.89 1/1.89 5.67 1.710 46 68 6.6 2000 D-7 180SWAN 24.71 21.16 6/2.12 1/2.12 6.36 1.356 58 85 8.3 2000 D-8 220

SWANATE 26.51 21.16 7/1.96 1/2.61 6.53 1.356 58 100 10.5 2000 D-8 250SWALLOW 31.10 26.65 6/2.38 1/2.38 7.14 1.076 73 108 10.2 2000 D-8 270SPARROW 39.22 33.61 6/2.67 1/2.67 8.01‘ 0.8530 92 136 12.7 2000 D-8 320

SPARATE 42.13 33.61 7/2.47 1/3.30 8.24 0.8530 92 159 16.2 2000 D-9 380ROBIN 49.49 42.39 6/3.00 1/3.00 9.00 0.6765 116 172 15.9 2000 D-9 405RAVEN 62.38 53.48 6/3.37 1/3.37 10.11 0.5364 147 216 19.5 2000 D-10 495

QUAIL 78.65 67.42 6/3.78 1/3.78 11.34 0.4255 185 273 23.5 2000 D-11 650PIGEON 99.22 85.03 6/4.25 1/4.25 12.75 0.3373 233 344 29.5 2000 D-12 800PENGUIN 125.10 107.23 6/4.77 1/4.77 14.31 0.2676 294 433 37.2 2000 D-12 975

WAXWING 142.64 135.16 18/3.09 1/3.09 15.45 0.2133 373 431 30.6 2000 D-14 1010PARTRIDGE 157.16 135.16 26/2.57 7/2.00 16.28 0.2142 375 547 50.2 2000 D-14 1240OSTRICH 176.77 152.00 26/2.73 7/2.12 17.28 0.1906 421 614 56.5 2000 D-16 1440

MERLIN 179.93 170.45 18/3.47 1/3.47 17.35 0.1692 470 544 38.7 2000 D-16 1300LINNET 198.19 170.45 26/2.89 7/2.25 18.31 0.1699 472 689 62.8 2000 D-16 1590ORIOLE 210.26 170.45 30/2.69 7/2.69 18.83 0.1704 473 784 77.2 2000 D-16 1780

CHICKADEE 212.58 201.42 18/3.77 7/3.77 18.85 0.1432 555 642 44.2 2000 D-16 1490BRANT 227.55 201.42 24/3.27 7/2.18 19.61 0.1438 558 762 65.1 2000 D-16 1730IBIS 234.19 201.42 26/3.14 7/2.44 19.88 0.1438 558 814 72.5 2000 D-16 1840

LARK 248.39 201.42 30/2.92 7/2.92 20.44 0.1442 560 927 90.4 2000 D-18 2090PELICAN 255.10 241.68 18/4.14 1/4.14 20.70 0.1193 666 771 52.3 2000 D-18 1780FLICKER 272.97 241.68 24/3.58 7/2.39 21.49 0.1199 670 915 76.3 2000 D-18 2070

HAWK 281.03 241.68 26/3.44 7/2.68 21.80 0.1199 670 977 87.0 2000 D-18 2190HEN 298.07 241.68 30/3.20 7/3.20 22.40 0.1202 671 1112 105.9 2000 D-18 2460

Conductor Area No. & NominalDiameter of Wires

Approx.Overall

Diameter

mm

Calculated D.CResistance

at 20ºC (Max.)

Ohm/Km

Approx.Conductor Weight

BreakingLoad

KN

StandardPackingLength

Metre ± 10%

DrumSize

ApproximateGrossWeight

Kg

Total Aluminium Aluminium Steel Aluminium Total

Kg/KmSqmm No./mm

CONDUCTORS FOR OVERHEAD LINES

ALUMINIUM CONDUCTORSTEEL REINFORCED

(ACSR)

Conductors conform to ATSM B 232 - 82 and CSA C 49 - 1975.

107C l i c k H e r e t o

N E X T P A G E

Page 107: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

CODE

PARAKEET 318.58 282.00 24/3.87 7/2.58 23.22 0.1028 781 1067 88.2 2000 D-18 2370DOVE 327.94 282.00 26/3.72 7/2.89 23.55 0.1028 781 1140 101.1 2000 D-18 2520EAGLE 347.81 282.00 30/3.46 7/3.46 24.21 0.1030 783 1298 123.6 2000 D-18 2840

PEACOCK 346.32 306.58 24/4.03 7/2.69 24.20 0.09449 850 1160 95.8 2000 D-18 2560SQUAB 356.52 306.58 26/3.87 7/3.01 24.51 0.09449 850 1240 106.9 2000 D-18 2720WOODDUCK 378.13 306.58 30/3.61 7/3.61 25.25 0.09473 851 1411 128.5 2000 D-19 3140

TEAL 376.45 306.58 30/3.61 19/2.16 25.24 0.09475 851 1397 133.4 2000 D-19 3110ROOK 364.07 322.26 24/4.14 7/2.76 24.84 0.08989 893 1219 101.0 2000 D-18 2680GROSBEAK 374.78 322.26 26/3.97 7/3.09 25.15 0.08989 893 1302 111.8 2000 D-19 2920

SCOTER 397.48 322.26 30/3.70 7/3.70 25.88 0.09011 895 1483 135.4 2000 D-19 3290EGRET 395.74 322.26 30/3.70 19/2.22 25.90 0.09012 894 1470 140.3 2000 D-19 3260FLAMINGO 381.55 337.74 24/4.23 7/2.82 25.40 0.08576 936 1278 105.9 2000 D-19 2880

GANNET 392.84 337.81 26/4.07 7/3.16 28.30 0.08576 936 1365 117.7 2000 D-21 3150CROW 409.55 362.58 54/2.92 7/2.92 26.28 0.07992 1005 1371 115.8 2000 D-19 3060STILT 409.61 362.64 24/4.39 7/2.92 26.31 0.07989 1005 1372 113.8 2000 D-19 3060

STARLING 421.61 362.58 26/4.21 7/3.28 26.68 0.07992 1005 1466 126.5 2000 D-19 3250REDWING 445.22 362.58 30/3.92 19/2.35 27.43 0.08009 1006 1653 154.0 2000 D-19 3630TERN 430.71 402.84 45/3.38 7/2.25 27.03 0.07192 1116 1333 98.3 2000 D-19 2990

CONDOR 455.03 402.84 54/3.08 7/3.08 27.72 0.07192 1116 1524 125.6 2000 D-19 3370MALLARD 494.71 402.84 30/4.14 19/2.48 28.96 0.07208 1119 1838 170.7 2000 D-21 4100CRANE 500.58 443.10 54/3.23 7/3.23 29.07 0.06539 1228 1676 138.3 2000 D-21 3770

RUDDY 487.35 455.81 45/3.59 7/2.40 28.73 0.06356 1263 1509 108.9 2000 D-21 3440CANARY 515.16 456.05 54/3.28 7/3.28 29.52 0.06352 1263 1724 142.2 2000 D-21 3870RAIL 516.84 483.42 45/3.70 7/2.47 29.61 0.05994 1339 1599 115.8 2000 D-21 3620

CARDINAL 546.07 483.42 54/3.38 7/3.38 30.42 0.05994 1339 1829 150.1 2000 D-22 4130

Conductor Area No. & NominalDiameter of Wires

Approx.Overall

Diameter

mm

Calculated D.CResistance

at 20ºC (Max.)

Ohm/Km

Approx.Conductor Weight

BreakingLoad

KN

StandardPackingLength

Metre ± 10%

DrumSize

ApproximateGrossWeight

Kg

Total Aluminium Aluminium Steel Aluminium Total

Kg/KmSqmm No./mm

CONDUCTORS FOR OVERHEAD LINES

ALUMINIUM CONDUCTORSTEEL REINFORCED

(ACSR)

Conductors conform to ASTM B 232 - 82 and CSA C49-1975

108C l i c k H e r e t o

N E X T P A G E

Page 108: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

CODE

ORTLAN 559.87 523.68 45/3.85 7/2.57 30.81 0.05531 1451 1734 123.6 2000 D-22 3940CURLEW 591.55 523.68 54/3.52 7/3.52 31.68 0.05531 1451 1981 162.8 2000 D-22 4430BLUEJAY 602.96 563.93 45/4.00 7/2.66 31.98 0.05161 1570 1875 132.4 2000 D-22 4220

FINCH 635.41 563.93 54/3.65 19/2.19 32.85 0.05161 1570 2130 173.6 1000 D-18 2370BUNTING 645.81 604.26 45/4.14 7/2.76 33.12 0.04820 1682 2008 142.2 1000 D-18 2250GRACKLE 680.78 604.26 54/3.77 19/2.27 33.97 0.04820 1682 2282 186.4 1000 D-18 2520

BITTERN 689.03 644.51 45/4.27 7/2.85 34.17 0.04518 1795 2143 152.1 1000 D-19 2460PHEASANT 726.19 644.51 54/2.34 19/2.34 35.10 0.04518 1795 2433 194.2 1000 D-19 2750DIPPER 732.26 685.16 45/4.40 7/2.92 35.16 0.04259 1906 2275 160.9 1000 D-19 2600

MARTIN 771.55 684.84 54/4.02 19/2.41 36.17 0.04259 1906 2585 206.0 1000 D-21 3010PLOVER 816.97 725.16 54/4.14 19/2.48 37.24 0.04016 2019 2738 217.8 1000 D-21 3160PARROT 862.32 765.16 54/4.25 19/2.55 38.25 0.03802 2131 2890 230.5 1000 D-21 3310

FALCON 908.12 805.80 54/4.36 19/2.62 39.26 0.03612 2243 3042 243.3 1000 D-21 3460

WREN 9.81 8.39 6/1.33 1/1.33 3.99 3.4226 23 34 3.3 2000 D6 110WARBLER 11.93 10.59 6/1.50 1/1.50 4.50 2.7139 29 43 4.2 2000 D-6 130PHOEBE 160.45 152.00 18/3.28 1/3.28 16.40 0.1893 418 483 35.5 2000 D-14 1120

PIPER 187.48 152.00 30/2.54 7/2.54 17.58 0.1903 420 697 68.7 2000 D-16 1600HERON 312.45 253.35 30/3.28 7/3.28 22.96 0.1142 701 1162 108.8 2000 D-18 2565SAPSUCKER 309.68 282.00 22/4.04 7/2.24 22.88 0.1024 777 993 79.1 2000 D-18 2230

DUCK 346.39 306.58 54/2.69 7/2.69 24.21 0.0945 848 1159 100.1 2000 D-18 2560GOOSE 364.00 322.26 54/2.76 7/2.76 24.84 0.0899 891 1217 105.3 2000 D-18 2670GULL 381.55 337.74 54/2.82 7/2.82 25.38 0.0856 935 1277 109.2 2000 D-19 2870

DRAKE 468.45 402.84 26/4.44 7/3.45 28.11 0.0715 1112 1624 139.1 2000 D-21 3670SCISSORTAIL 677.67 644.51 42/4.42 7/2.46 33.90 0.0449 1780 2039 144.4 1000 D-18 2280

Conductor Area No. & NominalDiameter of Wires

Approx.Overall

Diameter

mm

Calculated D.CResistance

at 20ºC (Max.)

Ohm/Km

Approx.Conductor Weight

BreakingLoad

KN

StandardPackingLength

Metre ± 10%

DrumSize

ApproximateGrossWeight

Kg

Total Aluminium Aluminium Steel Aluminium Total

Kg/KmSqmm No./mm

Conductors conform to ASTM B 232 - 1982 and CSA C 49 - 1975.

109

CONDUCTORS FOR OVERHEAD LINES

ALUMINIUM CONDUCTORSTEEL REINFORCED

(ACSR)

C l i c k H e r e t oN E X T P A G E

Page 109: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

Size

16/2.5 17.9 15.3 6/1.80 1/1.80 5.4 1.8750 42 62 5.8 2000 D-7 17025/4 27.8 23.8 6/2.25 1/2.25 6.8 1.2060 65 97 9.0 2000 D-8 24535/6 40.0 34.3 6/2.70 1/2.70 8.1 0.8365 94 140 12.4 2000 D-9 340

44/32 75.7 44.0 14/2.00 7/2.40 11.2 0.6570 122 372 44.1 2000 D-11 84550/8 56.3 48.3 6/3.20 1/3.20 9.6 0.5941 132 196 16.8 2000 D-10 45550/30 81.0 51.2 12/2.33 7/2.33 11.7 0.5642 141 378 43.0 2000 D-11 855

70/12 81.3 69.9 26/1.85 7/1.44 11.7 0.4130 193 284 26.3 2000 D-11 67095/12 109.7 94.4 26/2.15 7/1.67 13.6 0.3058 260 383 35.0 2000 D-12 88095/55 152.8 96.5 12/3.20 7/3.20 16.0 0.2992 266 712 77.8 2000 D-14 1570

105/75 181.5 105.7 14/3.10 19/2.25 17.5 0.2735 292 891 106.4 2000 D-16 1990120/20 141.4 121.6 26/2.44 7/1.90 15.5 0.2734 336 494 44.8 2000 D-14 1140120/70 193.7 122.0 12/3.60 7/3.60 18.0 0.2367 337 901 98.1 2000 D-16 2010

125/30 157.7 127.9 30/2.33 7/2.33 16.1 0.2259 353 591 56.5 2000 D-14 1330150/25 173.1 148.9 26/2.70 7/2.10 17.1 0.1939 411 605 54.2 2000 D-16 1420170/40 211.9 171.8 30/2.70 7/2.70 18.9 0.1682 475 794 75.3 2000 D-16 1800

185/30 213.6 183.8 26/3.00 7/2.33 19.0 0.1571 507 746 64.9 2000 D-16 1700210/35 243.2 209.1 26/3.20 7/2.49 20.3 0.1380 577 850 73.5 2000 D-18 1940210/50 261.6 212.1 30/3.00 7/3.00 21.0 0.1362 587 981 92.0 2000 D-18 2200

230/30 260.7 230.9 24/3.50 7/2.33 21.0 0.1249 638 877 71.7 2000 D-18 1990240/40 282.5 243.0 26/3.45 7/2.68 21.9 0.1188 671 987 84.8 2000 D-18 2210265/35 297.8 263.7 24/3.74 7/2.49 22.4 0.1094 728 1002 81.5 2000 D-18 2240

300/50 353.8 304.3 26/3.86 7/3.00 24.5 0.09486 840 1236 105.0 2000 D-18 2710305/40 344.1 304.6 54/2.68 7/2.68 24.1 0.09490 843 1160 97.5 2000 D-18 2560340/30 369.1 339.3 48/3.00 7/2.33 25.0 0.08508 938 1180 91.1 2000 D-18 2600

380/50 431.5 382.0 54/3.00 7/3.00 27.0 0.07568 1056 1458 120.8 2000 D-19 3240385/35 420.1 386.0 48/2.20 7/2.49 26.7 0.07494 1067 1344 102.8 2000 D-19 3010435/55 490.6 434.3 54/3.20 7/3.20 28.8 0.06656 1203 1653 133.9 2000 D-21 3730

450/40 488.2 448.7 48/3.45 7/2.68 28.7 0.06434 1241 1561 118.5 2000 D-21 3540490/65 533.9 490.3 54/3.40 7/3.40 30.6 0.05896 1356 1866 150.2 2000 D-22 4200550/70 621.3 550.0 54/3.60 7/3.60 32.4 0.05256 1520 2092 167.4 1000 D-18 2330

560/50 611.2 561.7 48/3.86 7/3.00 32.2 0.05140 1553 1954 146.1 1000 D-18 2190680/85 764.6 678.8 54/4.00 19/2.40 36.0 0.04259 1868 2570 206.4 1000 D-19 2890

Conductor Area No. & NominalDiameter of Wires

Approx.Overall

Diameter

mm

Calculated D.CResistance

at 20ºC (Max.)

Ohm/Km

Approx.Conductor Weight

BreakingLoad

KN

StandardPackingLength

Metre ± 10%

DrumSize

ApproximateGrossWeight

Kg

Total Aluminium Aluminium Steel Aluminium Total

Kg/KmSqmm No./mm

Conductors conform to DIN 48204.

110

CONDUCTORS FOR OVERHEAD LINES

ALUMINIUM CONDUCTORSTEEL REINFORCED

(ACSR)

C l i c k H e r e t oN E X T P A G E

Page 110: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

Number ofWires in

Conductor

HDBC7 110800 17.0 x 10-6

19 102900 17.0 x 10-6

37 102900 17.0 x 10-6

AAC3 61700 23.0 x 10-6

7 59000 23.0 x 10-6

19 56000 23.0 x 10-6

37 56000 23.0 x 10-6

ACSR

Aluminium Steel

6 1 79000 19.1 x 10-6

6 7 75000 19.8 x 10-6

7 7 74500 18.6 x 10-6

12 7 105000 15.3 x 10-6

14 19 99000 15.4 x 10-6

18 1 66000 21.2 x 10-6

24 7 72500 20.0 x 10-6

26 7 75500 19.2 x 10-6

30 7 80000 17.8 x 10-6

42 7 60800 21.3 x 10-6

45 7 62700 20.8 x 10-6

48 7 64700 20.2 x 10-6

54 7 69000 19.3 x 10-6

54 19 62700 19.3 x 10-6

111

Final Modulusof Elasticity

N/mm2

Coefficient ofLinear Expansion

Per º C

MODULUS OF ELASTICITY AND COEFFICIENT OFLINEAR EXPANSION TABLE

C l i c k H e r e t oH O M E

Page 111: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

CONDUCTOR FOR EARTHING

C l i c k H e r e t oN E X T P A G E

Page 112: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

114

4* 7 2.52 4.61 34.0 2000 D-6 1156* 7 3.08 3.08 51.0 2000 D-6 14510 7 3.8 1.83 87.0 2000 D-6 220

16 6 4.9 1.15 136 2000 D-6 31525 6 6.0 0.727 215 2000 D-7 47535 6 7.1 0.524 301 1000 D-7 345

50 6 8.2 0.387 410 1000 D-7 45570 12 9.8 0.268 594 1000 D-8 64595 15 11.7 0.193 820 1000 D-11 920

120 18 13.2 0.153 1040 1000 D-12 1150150 18 14.6 0.124 1300 1000 D-12 1410185 30 16.2 0.0991 1615 1000 D-14 1770

240 34 18.7 0.0754 2100 1000 D-16 2310300 34 20.7 0.0601 2650 1000 D-18 2890400 53 23.6 0.0470 3440 1000 D-18 3680

NominalArea of

Conductor

Sqmm

* Conductors circular stranded ( Class 2).all other conductors circular stranded compacted ( Class 2).Conductors conform to BS 6360 - 1991 and IEC 228 - 1978.Non- compacted untinned or tinned conductors available on Request.

CONDUCTOR FOR EARTHING PURPOSES

SOFT DRAWN BARE COPPER CONDUCTOR

(SDBC)

MinimumNumber of

Wires in theConductor

No

ApproxConductorDiameter

mm

MaximumConductor

Resistance at 20ºC

Ohm/km

ApproxConductor

Weight

Kg/Km

StandardPackingLength

Metre ± 10%

DrumSize

Approx.GrossWeight

Kg

C l i c k H e r e t oH O M E

Page 113: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

TELEPHONE CABLES

C l i c k H e r e t oN E X T P A G E

Page 114: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

116

0.4 10 0.165 0.73 1.7 11 100 1.7 11 7/1.6 23 280 1000 D-9 160 D-14 42020 1.7 13 135 1.7 13 7/1.6 25 315 1000 D-10 200 D-14 46030 1.7 14.5 180 1.7 14.5 7/1.6 26.5 365 1000 D-10 240 D-16 57050 1.7 17 260 1.7 17 7/1.6 29 450 1000 D-11 360 D-16 660

100 1.7 21 445 1.7 21 7/1.6 34 625 1000 D-12 560 D-19 950200 1.8 27.5 835 1.8 27.5 7/2.0 41.5 1155 1000 D-16 1050 D-22 1620

0.5 10 0.205 0.91 1.7 12 125 1.7 12 7/1.6 24 295 1000 D-9 190 D-14 44020 1.7 14.5 185 1.7 14.5 7/1.6 26.5 330 1000 D-10 250 D-16 54030 1.7 16 240 1.7 16 7/1.6 28 490 1000 D-11 340 D-16 70050 1.7 19 365 1.7 19 7/1.6 33.5 550 1000 D-12 480 D-19 870

100 1.7 24 640 1.7 24 7/2.0 38 930 1000 D-14 790 D-19 1250200 1.8 32 1190 1.8 32 7/2.0 46 1575 1000 D-19 1510 D-22 2040

0.65 10 0.255 1.16 1.7 14 160 1.7 14 7/1.6 26 310 1000 D-10 220 D-14 46020 1.7 16 255 1.7 16 7/1.6 28 420 1000 D-11 360 D-16 63030 1.7 19 360 1.7 19 7/1.6 31 550 1000 D-12 470 D-19 87050 1.7 22 550 1.7 22 7/2.0 36 810 1000 D-14 700 D-19 1130

100 1.8 30 985 1.8 30 7/2.0 45 1365 1000 D-18 1220 D-22 1830200 2.1 39 1850 - - - - - 500 D-16 1140 - -

0.9 10 0.305 1.51 1.7 16 245 1.7 16 7/1.6 28 430 1000 D-11 350 D-16 64020 1.7 21 420 1.7 21 7/2.0 35 700 1000 D-12 530 D-19 102030 1.7 24 590 1.7 24 7/2.0 38 865 1000 D-14 740 D-19 119050 1.8 29 935 1.8 29 7/2.0 44 1290 1000 D-18 1170 D-22 1760

100 2.0 37 1705 - - - - - 500 D-16 1060 - -200 2.3 52 3395 - - - - - 500 D-22 2170 - -

Sizeof

Conductor

Cables conform to Ministry of Communication, Kuwait, Specification for CCP-LAP & CCP -LAP-SS Cables.

PE INSULATED AND PE SHEATHED

TELEPHONE CABLES

(CCP-LAP & CCP- LAP-SS)

No.of

Pairs

InsulationThickness

NominalDia. OverInsulation

NominalThickness

of LAPSheath

(including)Aluminium

Tape)

Max.Overall

Diameterof Cable

Approx.CableWeight

NominalThickness

of LAPSheath

(includingAluminium

Tape)

Approx.Overall

Diameterof Cable

SelfSupporting

Strand

Approx.CableHeight

Approx.CableWeight

StandardPackingLength

DrumSize

Approx.GrossWeight

DrumSize

Approx.GrossWeight

CCP-LAP Self Supporting Type CCP-LAP-SS CCP-LAP Self Supporting TypeCCP-LAP-SS

mm No. mm mm mm mm Kg/Km mm mm No./mm mm Kg/Km Metre ± 10% Kg Kg

C l i c k H e r e t oN E X T P A G E

Page 115: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

117

0.4 10 0.165 0.73 1.7 1.25 2.5 19 430 1000 D-12 54020 1.7 1.25 2.5 21 540 1000 D-12 65030 1.7 1.25 2.5 22.5 620 1000 D-14 77050 1.7 1.6 2.5 26 870 1000 D-14 1020

100 1.7 1.6 2.5 30 1180 1000 D-18 1420200 1.8 2.0 2.5 37.5 1960 1000 D-19 2280

0.5 10 0.205 0.91 1.7 1.25 2.5 20 500 1000 D-12 61020 1.7 1.25 2.5 22.5 620 1000 D-14 77030 1.7 1.6 2.5 25 860 1000 D-14 101050 1.7 1.6 2.5 28 1060 1000 D-16 1270

100 1.7 1.6 2.5 33 1480 1000 D-19 1800200 1.8 2.0 2.5 42 2550 1000 D-22 3020

0.65 10 0.255 1.16 1.7 1.25 2.5 21 610 1000 D-12 72020 1.7 1.6 2.5 25 880 1000 D-14 103030 1.7 1.6 2.5 28 1020 1000 D-16 123050 1.7 1.6 2.5 31 1330 1000 D-19 1650

100 1.8 2.0 2.5 40 2200 1000 D-22 2670200 2.1 2.0 2.5 49 3460 500 D-19 2050

0.9 10 0.305 1.51 1.7 1.6 2.5 25 850 1000 D-14 100020 1.7 1.6 2.5 30 1110 1000 D-18 135030 1.7 1.6 2.5 33 1370 1000 D-19 169050 1.8 2.0 2.5 39 2090 1000 D-19 2410

100 2.0 2.0 2.5 47 3220 500 D-19 1930200 2.3 2.5 2.5 62 5830 500 D-22 3380

Sizeof

Conductor

No. ofPairs

InsulationThickness

NominalDiameter

OverInsulation

NominalThickness ofLAP Sheath(includingAluminium

Tape)

Diameter ofSteel Wire

Armour

NominalThickness

ofOuter Sheath

Approx.CableWeight

StandardPackingLength

Max. OverallDiameter of

Cable

Approx.GrossWeight

DrumSize

mm No. mm mm mm mm mm mm Kg/Km Metre ± 10% Kg

PE INSULATED STEEL WIRE

ARMOUREDC AND PE SHEATHED TELEPHONE CABLES

(CCP-LAP-A)

Cables conform to Ministry of Communication, Kuwait, Specification for CCP-LAP-A Cables.

C l i c k H e r e t oN E X T P A G E

Page 116: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

118

No. ofPairs

Thicknessof Insulation

Thicknessof Sheath

Approx.Overall

Diameter

Approx.CableWeight

StandardPackingLength

Approx.Coil

Weight

CoreIdentification

1 0.2 0.6 3.6 16 100Y Coil 1.5 W/B1.5 0.2 0.6 3.8 20 100Y Coil 1.8 W/B/G2* 0.2 0.6 4.0 23 100Y Coil 2.1 B/W,Br/BI

3 0.2 0.6 5.0 32 100Y Coil 2.9 W/B,WY,W/G4 0.2 0.6 5.5 39 100Y Coil 3.6 Above + W/R5 0.2 0.6 6.0 47 100Y Coil 4.3 Above + W/V

6 0.2 0.6 6.4 52 100Y Coil 4.8 Above + Br/B7 0.2 0.6 6.8 60 100Y Coil 5.5 Above + Br/Y8 0.2 0.6 7.1 67 100Y Coil 6.1 Above + Br/G

9 0.2 0.6 7.5 74 100Y Coil 6.8 Above + Br/R10 0.2 0.6 7.8 78 100Y Coil 7.1 Above + Br/V

No. mm mm mm Kg/Km Yards Kg Colour

INTERNAL NEWORK CABLES

TINNED COPPER CONDUCTOR, PVC INSULATED,

PVC SHEATHED

ATC/PVC/PVC: SIZE O.5MM SOLID

* Quad Consruction.Clours.. W-Whte, B-Blue, Y-Yellow, G-Green. R-Red, V-Violet, Br-Brown, Bl-Black.Color of sheath - Grey.Electrical Characteristics.Max Conductor D.C Resistance at 20ºC- 95.3 Ohm/Km.Min. Insulation Resistance at 20ºC - 500 M-Ohm-Km.Max - Average mutual Capacitance - 0.777 micro farad/KmMax. pair to pair Capacitance imbalance at 800 Hz - 300 picofarads/200 Mts.Cables conforms generally to MOC Kuwait specification.

C l i c k H e r e t oH O M E

Page 117: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

CURRENT RATINGS

TECHNICAL INFORMATIONS

C l i c k H e r e t oN E X T P A G E

Page 118: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

120

INSTALLATION CONDITIONS

1. Continuous operating temperature of conductor :-a) PVC type-5 insulated : 85º Cb) XLPE insulated : 90º C

2. Ambient temperature : 52º C

3. Temperature of ground : 35º C

4. Depth of laying in ground :-a) LV Cables : 750 mmb) MV Cables : 1000 mm

5. Thermal resistivity of soil : 1.2º C .m/W

OTHER CONDITIONS

A. LOW VOLTAGE CABLES 600/1000 V

1. SINGLE CORE CABLES

i) Two cables spaced one cable diameter installed vertical in air.ii) Two cables spaced one cable diameter laid horizontally underground.

2. MULTI CORE CABLES

i) Single cable touching wall installed in air.ii) Single isolated buried cable in ground.iii) Single cable installed in single isolated buried ducts -

a) Duct material : Earthen wareb) Depth of laying :-

i) LV Cables : 750 mmii) MV Cables : 1000 mm

c) Duct diameteri) Cable dia. up to 65 mm : OD = 130 mm & ID = 100 mmii) Cable dia. above 65 mm : OD = 160 mm & ID = 125 mm

B. MEDIUM VOLTAGE CABLES 6.6 KV TO 33 KV

1. SINGLE CORE CABLES

i) Three cables, trefoil, in air, two point bonding, separated from wall.ii) Three cables flat with a gap of one cable diameter installed vertically in air,

separated from wall. Single point or cross bonded.iii) Three cables with gap one cable diameter laid horizontally underground.

2. MULTI CORE CABLES

i) Single cable touching wall installed in air.ii) Single isolated buried cable in ground.

C l i c k H e r e t oN E X T P A G E

Page 119: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

121

INSTALLATION DETAILS

I) IN AIR (Installed on non-continuous brackets, ladder supports or cleats)

a) Single Core

1) Two cables spaced ‘De’ vertical :

2) Three cables trefoil :

3) Three cables (flat) spaced ‘De’ vertical :

b) Multi Core

1) Single cable touching wall :

II) IN GROUND

a) Single Core

1) Two cables spaced ‘De’ horizontal :

2) Three cables trefoil :

3) Three cables (flat) spaced ‘De’ horizontal :

b) Multi Core

1) Single isolated buried cable :

III) IN DUCT ( Multi Core Cables)

1) Single isolated buried ducts :

NOTE:-

De : External diameter of cableD : Depth of Laying

C l i c k H e r e t oN E X T P A G E

Page 120: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

122

NominalArea

ofConductor

Sqmm Unarmoured Armoured Unarmoured Armoured Unarmoured Armoured Unarmoured Armoured ** ** ** **

CURRENT CARRYING CAPACITY IN AMPERES

In Air In Ground

PVC Insulated XLPE Insulated PVC Insulated XLPE Insulated

Copper Aluminium Copper Aluminium Copper Aluminium Copper Aluminium

1.5 21 - - - 23 - - - 32 - 34 -2.5 28 - - - 31 - - - 42 - 45 -4 38 - - - 41 - - - 55 - 58 -

6 48 - - - 52 - - - 69 - 73 -10 66 - - - 71 - - - 91 - 97 -16 88 - 68 - 95 - 73 - 118 92 125 97

25 117 - 91 - 127 - 98 - 152 118 161 12535 144 - 112 - 156 - 121 - 183 142 194 15050 175 186 136 146 190 206 147 160 215 167 229 178

70 222 232 173 184 242 256 189 202 262 206 278 21895 276 284 215 224 301 313 234 246 312 245 330 259

120 322 327 250 258 352 359 273 284 350 276 371 293

150 370 368 287 292 405 405 314 320 387 307 410 324185 428 416 333 333 470 459 366 367 430 344 455 364240 513 483 400 390 565 533 440 430 486 392 515 416

300 592 541 461 440 653 597 508 485 533 435 565 461400 696 595 546 497 769 656 603 549 568 476 601 505500 813 659 641 561 901 727 710 619 614 525 651 555

630 955 726 778 642 1080 809 861 707 660 578 697 610800 1125 773 911 696 1247 850 1008 765 675 608 712 641

1000 1286 834 1051 760 1428 914 1165 834 707 648 744 682

*** l.a.1 l.a.1 l.a.1 l.a.1 l.a.1 l.a.1 l.a.1 l.a.1 Il.a.1 IIa.1 II.a.1 II.a.1

LOW VOLTAGE CABLES AND WIRES UPTO AND INCLUDING 600/1000V

COPPER OR ALUMINIUM CONDUCTORPVC OR XLPE INSULATED CABLESWITH OR WITHOUT PVC OUTER SHEATH

A. SINGLE CORE CABLES/ WIRES

Note

** Values can be applied safely for unarmoured cables also.*** Installation conditions (please refer at the beginning of this section).

C l i c k H e r e t oN E X T P A G E

Page 121: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

NominalArea

ofConductor

Sqmm

CURRENT CARRYING CAPACITY IN AMPERES

In Air In Ground

PVC Insulated XLPE Insulated PVC Insulated XLPE Insulated

Copper Aluminium

1.5 20 - 21 - 29 - 32 - 24 - 26 -2.5 27 - 28 - 38 - 41 - 32 - 34 -4 35 - 37 - 49 - 53 - 41 - 44 -

6 45 - 47 - 61 - 66 - 51 - 54 -10 62 - 63 - 81 - 87 - 67 - 72 -16 81 59 84 65 104 81 113 88 87 67 93 72

25 108 78 113 87 133 104 146 113 112 87 120 9335 130 95 137 106 160 124 174 135 135 105 145 11250 154 114 165 128 188 146 205 159 160 124 172 133

70 194 143 206 161 230 179 251 196 196 153 211 16495 238 175 254 198 275 214 301 234 237 184 255 198

120 273 201 293 228 312 243 341 266 269 210 290 226

150 309 228 332 259 348 271 381 297 301 235 325 253185 353 262 380 298 392 307 428 335 340 266 367 288240 414 308 447 351 451 355 494 388 392 309 424 334

300 468 348 506 399 503 397 552 435 438 346 475 375400 539 405 578 462 566 454 619 495 493 402 533 434

*** I.b.1 I.b.1 I.b.1 I.b.1 II.b.1 II.b.1 II.b.1 II.b.1 III.1 III.1 III.1 III.1

NoteAbove values can be applied safely for unarmoured cables also.*** Installation condition (please refer at the beginning of this section).

LOW VOLTAGE CABLES 600/1000 V

COPPER OR ALUMINIUM CONDUCTORPVC OR XLPE INSULATED CABLES

B. TWO CORE ARMOURED CABLES

123

In Duct

PVC Insulated XLPE Insulated

Copper Aluminium Copper Aluminium Copper Aluminium Copper Aluminium Copper Aluminium

C l i c k H e r e t oN E X T P A G E

Page 122: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

NoteAbove values can be applied safely for unarmoured cables also.*** Installation condition (please refer at the beginning of this section).

LOW VOLTAGE CABLES 600/1000 V

COPPER OR ALUMINIUM CONDUCTORPVC OR XLPE INSULATED CABLES

C. THREE OR FOUR CORE ARMOURED CABLES

124

NominalArea

ofConductor

Sqmm

CURRENT CARRYING CAPACITY IN AMPERES

In Air In Ground

PVC Insulated XLPE Insulated PVC Insulated XLPE Insulated

Copper Aluminium

1.5 15 - 17 - 25 - 27 - 20 - 22 -2.5 21 - 23 - 32 - 35 - 27 - 28 -4 28 - 30 - 42 - 45 - 35 - 37 -

6 35 - 38 - 53 - 57 - 43 - 46 -10 48 - 52 - 70 - 75 - 58 - 61 -16 65 50 70 54 92 71 98 76 75 58 79 61

25 84 66 91 71 114 89 122 95 96 74 101 7935 105 81 113 88 138 107 148 114 116 90 122 9550 129 100 140 108 165 128 176 137 138 107 146 113

70 161 125 175 136 201 156 215 167 169 131 179 13995 199 155 218 169 243 188 258 200 204 159 216 168

120 231 180 254 198 277 216 295 229 233 182 247 192

150 261 204 288 225 307 240 328 255 261 203 276 215185 301 235 333 260 348 272 371 290 295 231 313 244240 357 279 396 310 403 316 430 338 334 269 363 285

300 406 319 449 353 452 355 481 378 384 303 407 320400 471 375 519 414 512 408 545 433 443 347 469 373500 530 426 590 470 551 449 595 485 485 385 514 415

*** I.b.1 I.b.1 I.b.1 I.b.1 II.b.1 II.b.1 II.b.1 II.b.1 III.1 III.1 III.1 III.1

In Duct

PVC Insulated XLPE Insulated

Copper Aluminium Copper Aluminium Copper Aluminium Copper Aluminium Copper Aluminium

C l i c k H e r e t oN E X T P A G E

Page 123: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

NominalArea

ofConductor

Sqmm

35 152 170 117 132 154 160 119 12450 182 203 140 158 182 189 141 14670 227 254 175 198 222 231 172 179

95 274 313 211 240 264 275 204 212120 318 360 244 278 300 314 232 242150 360 410 278 316 335 352 261 272

185 410 470 330 365 376 399 294 309240 481 560 380 435 428 464 339 360300 545 640 430 498 472 525 379 407

400 625 750 500 585 517 600 427 468500 700 873 570 685 553 684 465 537630 784 1035 655 810 605 772 516 615

*** I.a.2 I.a.3 I.a.2 I.a.3 II.a.2 II.a.3 II.a.2 II.a.3

NoteAbove values can be applied safely for unarmoured cables also.*** Installation condition (please refer at the beginning of this section).

125

Trefoil

CURRENT CARRYING CAPACITY IN AMPERES

In Air In Ground

Copper Aluminium Copper Aluminium

Flat Trefoil Flat Trefoil Flat Trefoil Flat

MEDIUM VOLTAGE CABLES 3.8/6.6KV TO 19/33KV

COPPER OR ALUMINIUM CONDUCTORXLPE INSULATED CABLES

A. SINGLE CORE CABLES

B. THREE CORE CABLES

Nominal Areaof Conductor

Sqmm

35 130 100 145 11050 160 120 170 13070 196 151 210 160

95 240 184 250 193120 275 214 284 220150 312 240 318 246

185 355 277 360 279240 415 326 410 323300 469 370 458 362

400 530 427 510 411

*** I.b.1 I.b.1 II.b.1 II.b.1

CURRENT CARRYING CAPACITY IN AMPERES

In Air In Ground

Copper Aluminium Copper Aluminium

C l i c k H e r e t oN E X T P A G E

Page 124: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

Nominal Area ofConductor

Sqmm

0.5 2.7 2.7 20.75 5.4 5.4 31.0 9.0 9.0 5

1.25 11.7 11.7 51.5 14.4 14.4 52.5 22.5 18.0 5

4 28.8 22.5 5

Note

Above values can be taken as guide line for twin flat cables.

126

300/500 V - FLEXIBLE CORDS

COPPER CONDUCTORTYPE - 4 / TYPE - 5 PVC INSULATED CORDS

Current CarryingCapacity in Amperes

Maximum Mass supportedby flexible cord

Single-phaseA.C.

Three-phaseA.C.

Kg

C l i c k H e r e t oN E X T P A G E

Page 125: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

Ambient temperature º C 25 30 35 40 45 50 52 55 60

PVC insulated cables 1.35 1.29 1.22 1.16 1.09 1.02 1.00 0.95 0.86

XLPE insulated cables 1.37 1.30 1.24 1.17 1.09 1.03 1.00 0.95 0.88

Depth of laying is measured from surface of ground to the centre of a Cable/Duct or to the centre of a trefoil group of Cables/ducts as the case may be.

127

RATING FACTORS FOR VARIATION INAMBIENT TEMPERATURE FOR CABLES LAID IN AIR

Ground temperature ºC 15 20 25 30 35 40 45

PVC insulated cables 1.19 1.15 1.09 1.05 1.00 0.95 0.89

XLPE insulated cables 1.16 1.13 1.08 1.03 1.00 0.95 0.90

RATING FACTORS FOR VARIATION IN GROUND TEMPERATUREFOR CABLES LAID DIRECT IN GROUND OR IN DUCTS

RATING FACTORS FOR DEPTHS OF LAYING FORCABLES LAID DIRECT IN GROUND OR IN DUCTS

Depth ofLaying

Meter

0.50 1.026 1.036 1.055 1.044 1.026 - -0.60 1.015 1.016 1.023 1.023 1.015 - -0.75 1.000 1.000 1.000 1.000 1.000 - -

0.80 0.995 0.995 0.992 0.992 0.995 1.020 1.0311.00 0.974 0.974 0.970 0.971 0.985 1.000 1.0001.25 0.964 0.953 0.949 0.940 0.974 0.980 0.979

1.50 0.954 0.943 0.939 0.930 0.964 0.969 0.9691.75 0.944 0.922 0.918 0.919 0.964 0.959 0.9482.00 0.933 0.912 0.907 0.909 0.954 0.939 0.928

2.50 0.923 0.902 0.897 0.898 0.954 0.929 0.9183.00 0.913 0.891 0.876 0.888 0.944 0.918 0.907

or more

Upto50 Sqmm

70 Sqmm to300 Sqmm

Above300 Sqmm

Single Core Multicore

1.9/3.3 KV to 19/33 KV Cables

Above300 Sqmm

600/1000 V Cables

Cables Laid in Ground

Upto300 Sqmm

Cables Laid in Ducts Cables Laid in Ground

C l i c k H e r e t oN E X T P A G E

Page 126: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

No. ofCircuits

128

2 0.83 0.88 0.91 0.93 0.81 0.87 0.91 0.93 0.953 0.72 0.79 0.84 0.87 0.70 0.78 0.84 0.88 0.904 0.67 0.76 0.81 0.85 0.63 0.74 0.81 0.86 0.895 0.63 0.72 0.79 0.83 0.59 0.70 0.78 0.84 0.876 0.61 0.71 0.77 0.82 0.55 0.68 0.77 0.83 0.877 0.59 0.69 0.76 0.81 0.52 0.66 0.75 0.82 0.868 0.57 0.68 0.76 0.81 0.50 0.64 0.75 0.81 0.869 0.56 0.67 0.75 0.80 0.48 0.63 0.74 0.81 0.85

10 0.55 0.67 0.74 0.80 0.47 0.62 0.73 0.80 0.8511 0.54 0.66 0.74 0.80 0.45 0.61 0.73 0.80 0.8512 0.53 0.65 0.74 0.80 0.44 0.60 0.72 0.80 0.84

GROUP RATING FACTORS (0.6/1 KV CABLES) LAID IN GROUND

0.15 0.30 0.45 0.60 Touching 0.15 0.30 0.45 0.60

*Single Core Cable Laid Flat Horizontal Multicore Cable in Horizontal Formation

Spacing of Circuits (M) Spacing of Circuits (M)

* One circuit comprises of two cables laid horizontal with distance between adjacent cable surface equal to one cable diameter.

No. ofCircuits

2 0.78 0.80 0.81 0.85 0.88 0.90 0.80 0.85 0.89 0.90 0.923 0.66 0.69 0.71 0.76 0.80 0.83 0.69 0.75 0.80 0.84 0.864 0.60 0.63 0.65 0.72 0.76 0.80 0.63 0.70 0.77 0.80 0.845 0.55 0.58 0.61 0.68 0.73 0.77 0.57 0.66 0.73 0.78 0.816 0.52 0.55 0.58 0.66 0.72 0.76 0.55 0.63 0.71 0.76 0.80

GROUP RATING FACTORS (1.9/3.3 KV TO 19/33 KV CABLES) LAID IN GROUND

Trefoil Flat 0.15 0.30 0.45 0.60 Touching 0.15 0.30 0.45 0.60

3 Single Core Cable in Trefoil and Laid Flat Touching Horizontal Formation Multicore Cable in Horizontal Formation

Spacing Between Centres of Cable Group (M) Spacing Between Cables (M)

Touching

C l i c k H e r e t oN E X T P A G E

Page 127: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

129

RATING FACTORS FOR VARIATION IN THERMAL RESISTIVITY OF SOILTWIN OR MULTI -CORE CABLES LAID DIRECT IN THE GROUND

1.5/2.5 1.12 1.09 1.07 1.04 1.0 0.94 0.86 0.80 0.75 0.70 0.664 1.13 1.10 1.07 1.05 1.0 0.94 0.85 0.79 0.74 0.69 0.656 1.14 1.10 1.07 1.05 1.0 0.93 0.85 0.79 0.74 0.68 0.64

10 1.15 1.11 1.08 1.05 1.0 0.93 0.85 0.78 0.73 0.67 0.6316 1.16 1.12 1.08 1.05 1.0 0.93 0.84 0.77 0.72 0.66 0.6225 1.17 1.13 1.09 1.05 1.0 0.93 0.83 0.77 0.71 0.65 0.61

35 1.17 1.13 1.09 1.06 1.0 0.92 0.83 0.76 0.71 0.65 0.6150 1.17 1.13 1.09 1.06 1.0 0.92 0.83 0.76 0.71 0.65 0.6170 1.18 1.14 1.09 1.06 1.0 0.92 0.83 0.75 0.70 0.64 0.60

95 1.18 1.14 1.09 1.06 1.0 0.92 0.83 0.75 0.70 0.64 0.60120 1.19 1.14 1.10 1.06 1.0 0.92 0.82 0.75 0.69 0.63 0.60150 1.19 1.14 1.10 1.06 1.0 0.92 0.82 0.75 0.69 0.63 0.59

185 1.19 1.14 1.10 1.06 1.0 0.92 0.82 0.74 0.69 0.63 0.59240 1.20 1.15 1.10 1.07 1.0 0.92 0.81 0.74 0.69 0.63 0.59

300/400 1.20 1.15 1.10 1.07 1.0 0.92 0.81 0.74 0.69 0.63 0.59

Nominal Areaof Conductor

Sqmm 0.7 0.8 0.9 1.0 1.2 1.5 2.0 2.5 3.0 3.5 4.0

Thermal Resistivity of Soil in º C m/w

RATING FACTORS FOR VARIATION IN THERMAL RESISTIVITY OF SOILFOR TWO OR THREE SINGLE - CORE CABLES LAID DIRECT IN THE GROUND

50 1.21 1.16 1.11 1.07 1.0 0.91 0.81 0.73 0.68 0.63 0.5970 1.22 1.16 1.12 1.07 1.0 0.91 0.81 0.73 0.68 0.63 0.5995 1.22 1.16 1.12 1.07 1.0 0.91 0.81 0.73 0.68 0.63 0.59

120 1.22 1.16 1.12 1.07 1.0 0.91 0.81 0.73 0.68 0.63 0.59150 1.22 1.16 1.12 1.07 1.0 0.91 0.81 0.73 0.68 0.63 0.59185 1.22 1.17 1.12 1.07 1.0 0.91 0.81 0.73 0.68 0.62 0.59

240 1.23 1.17 1.12 1.07 1.0 0.91 0.80 0.73 0.68 0.62 0.59300 1.23 1.17 1.12 1.07 1.0 0.91 0.80 0.73 0.68 0.62 0.59400 1.23 1.17 1.12 1.07 1.0 0.91 0.80 0.73 0.67 0.62 0.58

500 1.23 1.17 1.12 1.07 1.0 0.91 0.80 0.73 0.67 0.62 0.58630 1.23 1.17 1.12 1.07 1.0 0.91 0.80 0.73 0.67 0.61 0.58800 1.23 1.17 1.12 1.07 1.0 0.91 0.80 0.72 0.66 0.61 0.58

1000 1.24 1.18 1.12 1.07 1.0 0.91 0.80 0.72 0.66 0.61 0.58

Nominal Areaof Conductor

Sqmm 0.7 0.8 0.9 1.0 1.2 1.5 2.0 2.5 3.0 3.5 4.0

Thermal Resistivity of Soil in º C m/w

C l i c k H e r e t oN E X T P A G E

Page 128: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

RATING FACTORS FOR VARIATION IN THERMAL RESISTIVITY OF SOILTWIN OR MULTI-CORE CABLES LAID IN SINGLE -WAY DUCTS

1.5/2.5 1.04 1.03 1.02 1.02 1.0 0.98 0.94 0.91 0.88 0.86 0.834 1.04 1.04 1.03 1.02 1.0 0.97 0.94 0.90 0.87 0.85 0.826 1.05 1.04 1.03 1.02 1.0 0.97 0.93 0.90 0.86 0.84 0.81

10 1.05 1.04 1.03 1.02 1.0 0.97 0.93 0.89 0.86 0.83 0.8016 1.06 1.04 1.03 1.02 1.0 0.97 0.92 0.88 0.85 0.82 0.7925 1.06 1.05 1.03 1.02 1.0 0.96 0.92 0.88 0.84 0.82 0.78

35 1.06 1.05 1.03 1.02 1.0 0.96 0.92 0.87 0.83 0.81 0.7750 1.07 1.05 1.03 1.02 1.0 0.96 0.91 0.87 0.83 0.80 0.7770 1.07 1.05 1.04 1.02 1.0 0.96 0.91 0.86 0.82 0.79 0.76

95 1.07 1.06 1.04 1.02 1.0 0.96 0.91 0.86 0.82 0.78 0.75120 1.08 1.06 1.04 1.03 1.0 0.95 0.90 0.85 0.81 0.78 0.74150 1.09 1.06 1.04 1.03 1.0 0.95 0.90 0.85 0.80 0.77 0.73

185 1.09 1.07 1.05 1.03 1.0 0.95 0.89 0.84 0.80 0.76 0.72240 1.09 1.07 1.05 1.03 1.0 0.95 0.89 0.84 0.79 0.76 0.72

300/400 1.10 1.07 1.05 1.03 1.0 0.95 0.88 0.83 0.78 0.75 0.71

Nominal Areaof Conductor

Sqmm 0.7 0.8 0.9 1.0 1.2 1.5 2.0 2.5 3.0 3.5 4.0

Thermal Resistivity of Soil in º C m/w

RATING FACTORS FOR VARIATION IN THERMAL RESISTIVITYOF SOIL TWO SINGLE - CORE CABLES IN DUCTS

50 1.08 1.06 1.04 1.03 1.0 0.96 0.90 0.85 0.81 0.77 0.7470 1.08 1.06 1.05 1.03 1.0 0.96 0.90 0.84 0.80 0.76 0.7395 1.08 1.07 1.05 1.03 1.0 0.95 0.89 0.84 0.80 0.75 0.72

120 1.09 1.07 1.05 1.03 1.0 0.95 0.89 0.83 0.79 0.75 0.71150 1.09 1.07 1.05 1.03 1.0 0.95 0.88 0.83 0.79 0.74 0.71185 1.09 1.07 1.05 1.03 1.0 0.95 0.88 0.83 0.78 0.74 0.70

240 1.10 1.08 1.05 1.04 1.0 0.95 0.88 0.82 0.78 0.73 0.70300 1.10 1.08 1.06 1.04 1.0 0.95 0.87 0.82 0.77 0.72 0.69400 1.11 1.08 1.06 1.04 1.0 0.94 0.87 0.82 0.77 0.72 0.68

500 1.12 1.08 1.06 1.04 1.0 0.94 0.87 0.81 0.76 0.71 0.68630 1.12 1.09 1.06 1.04 1.0 0.94 0.87 0.81 0.76 0.71 0.67800 1.13 1.10 1.07 1.04 1.0 0.94 0.86 0.80 0.75 0.71 0.67

1000 1.13 1.10 1.07 1.04 1.0 0.94 0.86 0.80 0.75 0.70 0.66

Nominal Areaof Conductor

Sqmm 0.7 0.8 0.9 1.0 1.2 1.5 2.0 2.5 3.0 3.5 4.0

Thermal Resistivity of Soil in º C m/w

130C l i c k H e r e t o

N E X T P A G E

Page 129: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

131

RATING FACTORS FOR VARIATION IN THERMAL RESISTIVITYOF SOIL THREE SINGLE- CORE CABLES IN DUCTS

50 1.11 1.08 1.06 1.04 1.0 0.94 0.87 0.82 0.77 0.73 0.6970 1.12 1.09 1.06 1.04 1.0 0.94 0.87 0.81 0.76 0.72 0.6895 1.12 1.09 1.06 1.04 1.0 0.94 0.87 0.81 0.76 0.72 0.68

120 1.13 1.10 1.07 1.04 1.0 0.94 0.86 0.80 0.75 0.72 0.67150 1.13 1.10 1.07 1.04 1.0 0.94 0.86 0.80 0.75 0.71 0.67185 1.13 1.10 1.07 1.04 1.0 0.93 0.86 0.79 0.75 0.70 0.67

240 1.14 1.11 1.07 1.04 1.0 0.93 0.86 0.79 0.74 0.70 0.66300 1.14 1.11 1.08 1.05 1.0 0.93 0.85 0.79 0.74 0.69 0.65400 1.14 1.11 1.08 1.05 1.0 0.93 0.85 0.78 0.73 0.68 0.65

500 1.15 1.11 1.08 1.05 1.0 0.93 0.85 0.78 0.73 0.68 0.64630 1.15 1.12 1.08 1.05 1.0 0.93 0.84 0.78 0.72 0.68 0.64800 1.16 1.12 1.09 1.05 1.0 0.93 0.84 0.77 0.72 0.67 0.64

1000 1.16 1.13 1.09 1.05 1.0 0.92 0.84 0.77 0.71 0.67 0.63

Nominal Areaof Conductor

Sqmm 0.7 0.8 0.9 1.0 1.2 1.5 2.0 2.5 3.0 3.5 4.0

Thermal Resistivity of Soil in º C m/w

C l i c k H e r e t oH O M E

Page 130: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

VOLTAGE DROP

TECHNICAL INFORMATIONS

C l i c k H e r e t oN E X T P A G E

Page 131: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

134

1.5 26.3 26.3 - - 30.4 - 26.3 -2.5 16.1 16.1 - - 18.6 - 16.1 -4 10.0 10.0 - - 11.6 - 10.0 -

6 6.7 6.7 - - 7.7 - 6.7 -10 4.0 4.0 - - 4.6 - 4.0 -16 2.5 2.5 4.8 4.8 2.9 4.8 2.5 4.8

25 1.55 1.60 3.1 3.1 1.8 3.1 1.6 3.135 1.13 1.16 2.2 2.2 1.3 2.2 1.2 2.250 0.84 0.87 1.4 1.5 0.98 1.7 0.85 1.7

70 0.60 0.65 0.96 0.98 0.69 1.2 0.60 1.295 0.45 0.52 0.70 0.76 0.51 0.89 0.44 0.89

120 0.37 0.45 0.57 0.64 0.41 0.74 0.36 0.74

150 0.31 0.41 0.47 0.55 0.35 0.64 0.30 0.64185 0.26 0.38 0.38 0.48 0.29 0.56 0.25 0.56240 0.23 0.35 0.31 0.42 0.24 0.48 0.21 0.48

300 0.20 0.33 0.26 0.38 0.21 0.44 0.18 0.44400 0.19 0.32 0.25 0.37 0.19 0.41 0.16 0.41500 0.18 0.31 0.25 0.36 0.17 0.39 0.15 0.39

630 0.16 0.31 0.24 0.36 0.16 0.37 - -800 0.16 0.30 0.24 0.35 0.15 0.36 - -

1000 0.15 0.29 0.23 0.35 0.15 0.35 - -

NominalArea of

Conductor

Sqmm

* Adjacent Cables spaced by one Cable diameter.Maximum conductor operating temperature for Type 5 PVC insulated Cables...............................85º C

3 or 4 Single Core Cables

CopperTrefoil

CopperFlat spaced*

AluminiumTrefoil

AluminiumFlat spaced*

Copper Aluminium Copper Aluminium

2 Core or 2 Single CoreCables - Touching

3 and 4 Core Cables

VOLTAGE DROP

600/1000 V TYPE-5 PVC INSULATED CABLES

VOLTAGE DROPS AT MAXIMUMCONDUCTOR OPERATING TEMPERATURE IN V/A/KM

C l i c k H e r e t oN E X T P A G E

Page 132: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

135

1.5 26.7 26.7 - - 30.9 - 26.7 -2.5 16.4 16.4 - - 18.9 - 16.4 -4 10.2 10.2 - - 11.8 - 10.2 -

6 6.8 6.8 - - 7.9 - 6.8 -10 4.0 4.0 - - 4.7 - 4.0 -16 2.5 2.5 4.2 4.2 2.9 4.8 2.5 4.2

25 1.65 1.65 2.7 2.7 1.9 3.1 1.65 2.735 1.15 1.15 1.95 1.95 1.35 2.2 1.15 1.9550 0.87 0.90 1.40 1.40 1.0 1.65 0.87 1.45

70 0.62 0.70 0.98 1.05 0.69 1.15 0.60 0.9795 0.47 0.58 0.74 0.83 0.52 0.84 0.45 0.72

120 0.39 0.51 0.60 0.70 0.42 0.72 0.37 0.58

150 0.33 0.45 0.49 0.60 0.35 0.61 0.30 0.47185 0.28 0.41 0.41 0.53 0.29 0.52 0.26 0.39240 0.24 0.37 0.34 0.46 0.24 0.44 0.21 0.31

300 0.21 0.34 0.29 0.41 0.21 0.39 0.19 0.26400 0.20 0.33 0.25 0.36 0.20 0.36 0.17 0.21500 0.18 0.31 - - 0.17 0.34 0.16 0.19

630 0.17 0.29 - - 0.16 0.32 - -800 0.16 0.28 - - 0.15 0.31 - -

1000 0.16 0.27 - - 0.15 0.29 - -

NominalArea of

Conductor

Sqmm

* Adjacent Cables spaced by one Cable diameter.Maximum conductor operating temperature for XLPE insulated Cables.........................................................................................90ºC

3 or 4 Single Core Cables

CopperTrefoil

CopperFlat spaced*

AluminiumTrefoil

AluminiumFlat spaced*

Copper Aluminium Copper Aluminium

2 Core or 2 Single CoreCables - Touching

3 and 4 Core Cables

VOLTAGE DROP

600/1000 V XLPE INSULATED CABLES

VOLTAGE DROPS AT MAXIMUMCONDUCTOR OPERATING TEMPERATURE IN V/A/KM

C l i c k H e r e t oH O M E

Page 133: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

A.C. RESISTANCE, REACTANCEAND

CAPACITANCE VALUES

TECHNICAL INFORMATIONS

C l i c k H e r e t oN E X T P A G E

Page 134: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

138

NominalArea

ofConductor

Sqmm

1.0 22.72 - - - - - 0.116 - - - - - - -1.5 15.19 - 15.19 - - - 0.115 15.43 - 15.43 - - - 0.1152.5 9.30 - 9.30 - - - 0.111 9.45 - 9.45 - - - 0.107

4 5.79 - 5.79 - - - 0.096 5.88 - 5.88 - - - 0.0936 3.87 - 3.87 - - - 0.092 3.93 - 3.93 - - - 0.089

10 2.30 - 2.30 - - - 0.091 2.33 - 2.33 - - - 0.084

16 1.44 2.41 1.44 2.41 0.121 0.210 0.086 1.47 2.42 1.47 2.42 0.114 0.172 0.08125 0.913 1.51 0.913 1.51 0.116 0.202 0.085 0.927 1.54 0.927 1.54 0.113 0.172 0.08135 0.658 1.10 0.658 1.10 0.115 0.201 0.083 0.668 1.11 0.668 1.11 0.110 0.167 0.079

50 0.486 0.809 0.486 0.809 0.112 0.195 0.080 0.494 0.822 0.494 0.822 0.106 0.161 0.07570 0.337 0.559 0.337 0.559 0.107 0.188 0.077 0.342 0.568 0.342 0.568 0.103 0.160 0.07495 0.243 0.405 0.243 0.405 0.103 0.186 0.077 0.247 0.411 0.247 0.411 0.098 0.155 0.073

120 0.193 0.320 0.193 0.320 0.103 0.185 0.075 0.197 0.325 0.197 0.325 0.097 0.153 0.072150 0.159 0.261 0.159 0.261 0.101 0.185 0.075 0.160 0.265 0.160 0.265 0.097 0.153 0.072185 0.126 0.208 0.126 0.208 0.099 0.184 0.074 0.128 0.211 0.128 0.211 0.096 0.153 0.072

240 0.0970 0.160 0.0972 0.160 0.096 0.181 0.074 0.0986 0.162 0.0989 0.162 0.092 0.147 0.071300 0.0785 0.129 0.0786 0.129 0.094 0.180 0.073 0.0800 0.130 0.0802 0.130 0.090 0.147 0.070400 0.0628 0.100 0.0630 0.101 0.091 0.178 0.073 0.0640 0.102 0.0645 0.102 0.090 0.146 0.070

. 500 0.0515 0.0793 0.0518 0.0795 0.089 0.176 0.072 0.0525 0.0810 0.0530 0.0810 0.089 0.146 0.070630 0.0426 0.0648 - - 0.086 0.173 - 0.0428 0.0658 - - 0.086 0.144 -800 0.0357 0.0533 - - 0.086 0.171 - 0.0380 0.0541 - - 0.084 0.143 -

1000 0.0310 0.0451 - - 0.084 0.168 - 0.0334 0.0457 - - 0.081 0.140 -

A.C. Resistance 85ºC

Copper

600/1000 V CABLES

A.C. RESISTANCE AND REACTANCE VALUES

PVC (TYPE 5) INSULATED CABLES XLPE INSULATED CABLES

Reactance at 50 Hz A.C. Resistance at 90ºC Reactance at 50 Hz

* Single Core Cables Multicore Cables * Single Core Cables MulticoreCables

* Single Core Cables Multicore Cables * Single Core Cables MulticoreCables

Aluminium Copper Aluminium Trefoil Flat Copper Aluminium Copper Aluminium Trefoil Flat

Ohm/km Ohm/km Ohm/km Ohm/km Ohm/km Ohm/km Ohm/km Ohm/km

* Aluminium wire armoured Cable.

C l i c k H e r e t oN E X T P A G E

Page 135: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

Conductorsize

Sq.mm

35 0.668 1.11 0.140 0.198 0.29 0.668 1.11 0.108 0.3050 0.494 0.822 0.131 0.189 0.33 0.494 0.922 0.103 0.3370 0.342 0.568 0.123 0.181 0.37 0.342 0.568 0.098 0.38

95 0.247 0.411 0.117 0.175 0.42 0.247 0.411 0.094 0.43120 0.196 0.325 0.112 0.170 0.47 0.196 0.325 0.090 0.48150 0.159 0.265 0.109 0.167 0.51 0.159 0.265 0.088 0.52

185 0.127 0.211 0.107 0.165 0.55 0.127 0.211 0.086 0.56240 0.0974 0.161 0.103 0.161 0.60 0.0971 0.162 0.083 0.61300 0.0782 0.129 0.101 0.159 0.61 0.0778 0.130 0.082 0.62

400 0.0621 0.101 0.097 0.156 0.64 0.0614 0.102 0.080 0.65500 0.0495 0.0792 0.097 0.155 0.67 - - - -630 0.0398 0.0623 0.094 0.152 0.75 - - - -

Reactance (50 Hz) Capacitance

Copper(Ω/km)

Trefoil(Ω/km)

* Single Core Cables 3-Core Cables

A.C. Resistance at 90ºC A.C. Resistance at 90ºC Reactance(50 Hz)

Capacitance

Aluminium(Ω/km)

Flat*(Ω/km)

Copper(Ω/km)( µF/km)

Aluminium(Ω/km) (F/Km)(Ω/km)

3.8/6.6 KV CABLES

A.C. RESISTANCE, REACTANCE AND CAPACITANCE VALUES

* Twice Cable diameter spacing between centres.

Conductorsize

Sq.mm

35 0.668 1.11 0.142 0.20 0.23 0.668 1.11 0.116 0.2450 0.494 0.822 0.135 0.194 0.26 0.494 0.822 0.111 0.2670 0.342 0.568 0.128 0.186 0.29 0.342 0.568 0.105 0.29

95 0.247 0.411 0.121 0.179 0.33 0.247 0.411 0.100 0.34120 0.196 0.325 0.116 0.174 0.36 0.196 0.325 0.097 0.37150 0.159 0.265 0.114 0.173 0.39 0.159 0.265 0.093 0.40

185 0.127 0.211 0.111 0.169 0.42 0.128 0.211 0.091 0.43240 0.0973 0.161 0.106 0.164 0.47 0.097 0.161 0.087 0.48300 0.0782 0.129 0.102 0.161 0.51 0.0778 0.129 0.085 0.52

400 0.0620 0.101 0.099 0.157 0.57 0.0614 0.101 0.082 0.59500 0.0494 0.0792 0.098 0.156 0.63 - - - -630 0.0396 0.0623 0.094 0.152 0.71 - - - -

Reactance (50 Hz) Capacitance

Copper(Ω/km)

Trefoil(Ω/km)

* Single Core Cables 3-Core Cables

A.C. Resistance at 90ºC A.C. Resistance at 90ºC Reactance(50 Hz)

Capacitance

Aluminium(Ω/km)

Flat*(Ω/km)

Copper(Ω/km)( µF/km)

Aluminium(Ω/km) (F/Km)(Ω/km)

*Twice Cable diameter spacing between centres.

6.35/11 KV CABLESA.C. RESISTANCE, REACTANCE AND CAPACITANCE VALUES

139C l i c k H e r e t o

N E X T P A G E

Page 136: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

Conductorsize

Sq.mm

35 0.668 1.11 0.147 0.206 0.19 0.668 1.11 0.124 0.19

50 0.494 0.822 0.141 0.199 0.21 0.494 0.822 0.119 0.2170 0.342 0.568 0.133 0.191 0.23 0.342 0.568 0.112 0.24

95 0.247 0.411 0.128 0.185 0.26 0.247 0.411 0.106 0.27120 0.196 0.325 0.122 0.180 0.29 0.196 0.325 0.102 0.29150 0.159 0.265 0.118 0.176 0.31 0.159 0.265 0.099 0.31

185 0.127 0.211 0.115 0.173 0.33 0.127 0.211 0.096 0.34240 0.0973 0.161 0.109 0.167 0.37 0.0970 0.161 0.092 0.38300 0.0780 0.129 0.106 0.164 0.40 0.0778 0.129 0.090 0.41

400 0.0619 0.101 0.104 0.162 0.45 0.0614 0.101 0.086 0.46500 0.0493 0.0792 0.101 0.159 0.50 - - - -630 0.0395 0.0622 0.097 0.155 0.55 - - - -

Reactance (50 Hz) Capacitance

Copper(Ω/km)

Trefoil(Ω/km)

* Single Core Cables 3-Core Cables

A.C. Resistance at 90ºC A.C. Resistance at 90ºC Reactance(50 Hz)

Capacitance

Aluminium(Ω/km)

Flat*(Ω/km)

Copper(Ω/km)( µF/km)

Aluminium(Ω/km) (F/Km)(Ω/km)

8.7/15 KV CABLES

A.C. RESISTANCE, REACTANCE AND CAPACITANCE VALUES

* Twice Cable diameter spacing between centres.

Conductorsize

Sq.mm

35 0.668 1.11 0.138 0.196 - 0.668 1.11 0.131 0.1750 0.494 0.822 0.132 0.190 0.19 0.494 0.822 0.125 0.1870 0.342 0.568 0.125 0.183 0.22 0.342 0.568 0.118 0.20

95 0.247 0.411 0.118 0.176 0.24 0.247 0.411 0.112 0.23120 0.196 0.325 0.113 0.171 0.26 0.196 0.325 0.107 0.25150 0.159 0.265 0.110 0.168 0.28 0.159 0.265 0.104 0.27

185 0.127 0.211 0.107 0.164 0.30 0.127 0.211 0.101 0.29240 0.0974 0.161 0.102 0.160 0.34 0.0970 0.161 0.096 0.32300 0.0782 0.129 0.099 0.157 0.37 0.0778 0.129 0.093 0.35

400 0.0621 0.101 0.096 0.154 0.40 0.0614 0.101 0.090 0.39500 0.0495 0.0791 0.093 0.151 0.44 - - - -630 0.0398 0.0621 0.090 0.148 0.49 - - - -

Reactance (50 Hz) Capacitance

Copper(Ω/km)

Trefoil(Ω/km)

* Single Core Cables 3-Core Cables

A.C. Resistance at 90ºC A.C. Resistance at 90ºC Reactance(50 Hz)

Capacitance

Aluminium(Ω/km)

Flat*(Ω/km)

Copper(Ω/km)( µF/km)

Aluminium(Ω/km) (F/Km)(Ω/km)

*Twice Cable diameter spacing between centres.

12.7/22 KV CABLES

A.C. RESISTANCE, REACTANCE AND CAPACITANCE VALUES

140C l i c k H e r e t o

N E X T P A G E

Page 137: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

Conductorsize

Sq.mm

50 0.494 0.822 0.157 0.215 0.14 0.494 0.817 0.138 0.1470 0.342 0.568 0.148 0.206 0.15 0.342 0.568 0.130 0.1695 0.247 0.411 0.140 0.198 0.17 0.246 0.411 0.123 0.18

120 0.196 0.325 0.134 0.192 0.19 0.196 0.325 0.118 0.19150 0.159 0.265 0.132 0.190 0.20 0.159 0.264 0.114 0.20185 0.127 0.211 0.128 0.186 0.21 0.127 0.211 0.110 0.22

240 0.0972 0.161 0.121 0.179 0.24 0.0970 0.161 0.105 0.24300 0.0780 0.129 0.118 0.176 0.25 0.0777 0.129 0.102 0.26400 0.0617 0.101 0.113 0.172 0.28 - - - -

500 0.0491 0.0793 0.110 0.168 0.31 - - - -

Reactance (50 Hz) Capacitance

Copper(Ω/km)

Trefoil(Ω/km)

* Single Core Cables 3-Core Cables

A.C. Resistance at 90ºC A.C. Resistance at 90ºC Reactance(50 Hz)

Capacitance

Aluminium(Ω/km)

Flat*(Ω/km)

Copper(Ω/km)( µF/km)

Aluminium(Ω/km) (F/Km)(Ω/km)

19/33 KV CABLES

A.C. RESISTANCE, REACTANCE AND CAPACITANCE VALUES

* Twice Cable diameter spacing between centres.

141C l i c k H e r e t o

H O M E

Page 138: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

SHORT CIRCUIT CURVES

TECHNICAL INFORMATIONS

C l i c k H e r e t oN E X T P A G E

Page 139: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

SHORT CIRCUIT TIME (Sec.) t.

MA

X. S

HO

RT

CIR

CU

IT C

UR

RE

NT

KA

144

SHORT CIRCUIT CURRENT CURVES FOR COPPERCONDUCTOR PVC INSULATED CABLES

Isc - Short Circuit Current in KAA - Conductor Area in Sqmmt - Short Circuit Time in Sec.

A

Isc = 0.11

t√

CO

ND

UC

TO

R A

RE

A S

qmm

C l i c k H e r e t oN E X T P A G E

Page 140: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

145

SHORT CIRCUIT CURRENT CURVES FORCOPPER CONDUCTOR XLPE INSULATED CABLES

Isc - Short Circuit Current in KAA - Conductor Area in Sqmmt - Short Circuit Time in Sec.

A

Isc = 0.14

t√

SHORT CIRCUIT TIME (Sec.) t.

MA

X. S

HO

RT

CIR

CU

IT C

UR

RE

NT

KA

CO

ND

UC

TO

R A

RE

A S

qmm

C l i c k H e r e t oN E X T P A G E

Page 141: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

146

SHORT CIRCUIT CURRENT CURVES FORALUMINIUM CONDUCTOR PVC INSULATED CABLES

Isc - Short Circuit Current in KAA - Conductor Area in Sqmmt - Short Circuit Time in Sec.

A

Isc = 0.07

t√

SHORT CIRCUIT TIME (Sec.) t.

MA

X. S

HO

RT

CIR

CU

IT C

UR

RE

NT

KA

CO

ND

UC

TO

R A

RE

A S

qmm

C l i c k H e r e t oN E X T P A G E

Page 142: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

147

SHORT CIRCUIT CURRENT CURVES FORALUMINIUM CONDUCTOR XLPE INSULATED CABLES

Isc - Short Circuit Current in KAA - Conductor Area in Sqmmt - Short Circuit Time in Sec.

A

Isc = 0.094

t√

SHORT CIRCUIT TIME (Sec.) t.

MA

X. S

HO

RT

CIR

CU

IT C

UR

RE

NT

KA

CO

ND

UC

TO

R A

RE

A S

qmm

C l i c k H e r e t oH O M E

Page 143: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

DRUMS

C l i c k H e r e t oN E X T P A G E

Page 144: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

150

D-6 600 250 470 400 110D-7 700 325 570 500 110D-8 800 375 570 500 110

D-9 900 425 620 550 110D-10 1000 500 690 600 110D-11 1100 575 740 650 110

D-12 1200 675 950 850 110D-14 1400 800 950 850 110D-16 1600 950 970 850 110

D-18 1800 1100 1220 1100 110D-19 1900 1100 1230 1100 110D-20 2000 1300 1235 1100 110

D-21 2100 1150 1290 1100 110D-22 2200 1400 1390 1250 110D-23 2340 1200 1795 1625 110

D-24 2400 1200 1795 1625 110D-25-S 2540 1200 1825 1625 110D-25 2540 1400 1800 1625 110D-26 2600 1400 1970 1800 110

DRUMS SIZES AND DIMENSIONS

A - Flange diameter (excluding lagging), mmB - Barrel diameter, mmC - Overall width, mmD - Traverse width, mmE - Minimum spindle hole diameter, mm

DIAMENSIONS

Drum SizeD-No

A B C D E

Drum dimensions in actual deliveries are subject to change without notice.

C l i c k H e r e t oH O M E

Page 145: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

CABLE JOINTS

C l i c k H e r e t oN E X T P A G E

Page 146: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

152C l i c k H e r e t o

N E X T P A G E

Page 147: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

153

GC CABLE JOINTS

Gulf Cable & Electrical Industries Company (GC) produces cable joint encapsulationcompounds which are widely used by Electrical Supply industries in many countries.

1. The performance of the GC Joints & Pots Ends meets the British Recommendation C 81 Part 2

2. Mechanical connectors and armour bonding system comply with BS 4579 and Engineering Council Recommendation C 79.

The encapsulation system (BERPAK 252 & BERPAK 516) is based on Polyurethane compounds produced by the mixing of two meterialsto form a free-flowing liquid which cures into tough resilient elastomer. The two meterials are supplied in separate containers. The twomaterials used consist a Base material (Part B) & an Activator (Part A).

The GC Cable Joints System is convenient for jointing cables upto 1000 V a.c & 1500V d.c. it has the suitability to use with PVCInsulated, XLPE Insulated, Paper insulated, PVC Sheathed Armoured or Umarmoured cables. The system is designed to be appropriate forCopper & Aluminium conductors cables.

The mechanical jointing is suitable for cores of standard solid Aluminium, in both circular and sector-shaped cross -sections, the coreshapes being taken into account in the design of specific connectors.

The Outer Shells of the GC Joints have been designed to avoid the air bubbles trapping inside the joint.

The products range include the following products:

1. Straight Through Joints.2. Branch / Service Joints.3. Double Branch / Service Joints.4. Pilot Cable Joints.5. Street Lighting Joints.6. Pot Ends.

If Copper conductors are to be jointed they should be wrapped in brass qauze before insertion in to the yoke to improve electrical stabilityof the Aluminium\Copper interface in the connection.

Health & Safety:

Berpak Cable Jointing Compounds have been proven to be safe to handle as normal hygienic principles are observed. It is recommendedthat personal should wash hands before eating or smoking.

The base compounds contain a Polyurethane and the curing agents contain an Isocyanate. The T.L.V. for the MDI ( Methylene BisphenylDi Isocyanate) is . 002 ppm. However it is of low volantility at room temperature and may be regarded as being free from isocyanate vapourhazard.

C l i c k H e r e t oN E X T P A G E

Page 148: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

154C l i c k H e r e t o

N E X T P A G E

Page 149: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

155

STRAIGHT THROUGH JOINTS

Cable Specification:

1. Connductors:Copper & Aluminium Conductors

2. Insulation & Sheathing:PVC Insulated, XLPE Insulated, Paper Insulated, PVC Sheathed Armoured or Unarmoured cables.

3. Voltage Range:Upto 1000 V a.c & 1500 V d.c.

Cable Joint Kit Contents:

The kit contents encloses the following items:

1. Adequate Number of Mechanical Connectors.2. Cable Joint Outer Shell (Top + Bottom + Cap).3. Armour Bonding System in case of Armoured Cables (Earth Continuity).4. Adequate Number of Brass Gauses in case of Copper Conductors.5. Water Sealent Strip in case of PILC Cables.

1 Straight Th. Joint 500 /500 1-4

2 Straight Th. Joint 500 /300 1-4

3 Straight Th. Joint 300 /300 1-4

4 Straight Th. Joint 300 /185 1-4

5 Straight Th. Joint 300 /150 1-4

6 Straight Th. Joint 240 /240 1-4

7 Straight Th. Joint 150/150 1-4

8 Straight Th. Joint 150 /70 1-4

9 Straight Th. Joint 120 /120 1-4

10 Straight Th. Joint 120 /70 1-4

11 Straight Th. Joint 95 /95 1-4

12 Straight Th. Joint 70 /70 1-4

13 Straight Th. Joint 50 /50 1-4

14 Straight Th. Joint 50 /35 1-4

15 Straight Th. Joint 25/25 1-4

16 Straight Th. Joint 16/16 1-4

S.No. No. of CoresCores Size (Sqmm)

* Other sizes can be prepared as per the requirments of the customers

C l i c k H e r e t oN E X T P A G E

Page 150: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

156C l i c k H e r e t o

N E X T P A G E

Page 151: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

157

BRANCH / SERVICE JOINTS

Cable Specifications:

1. Conductors:Copper & Aluminium Conductors

2. Insulation & Sheathing:

PVC Insulated, XLPE Insulated, Paper Insulated,PVC Sheathed Armoured or Unarmoured cables

3. Voltage Range:Upto 1000V a.c. & 1500V d.c.

Cable Joint Kit Contents:

The Kit content encloses the following items:

1. Adequate Number of Mechanical Connectors.2. Cable Joint Outer Shell (Top + Bottom + Cap).3. Armour Bonding System in case of armoured

Cables (Earth Continuity).4. Adequate Number of Brass Gauses in case of

Copper Conductors.5. Water Sealent Strip in case of PILC Cables.

1 Branch Joint 500 / 300 1-4

2 Branch Joint 500 / 95 1-4

3 Branch Joint 300 / 300 1-4

4 Branch Joint 300 /240 1-4

5 Branch Joint 185 / 300 1-4

6 Branch Joint 300 / 150 1-4

7 Branch Joint 300 / 120 1-4

8 Branch Joint 300 / 95 1-4

9 Branch Joint 300 / 70 1-4

10 Branch Joint 300 / 50 1-4

11 Branch Joint 300 / 35 1-4

12 Branch Joint 240 / 240 1-4

13 Branch Joint 240 / 70 - 120 1-4

14 Branch Joint 240 / 25 1-4

15 Branch Joint 70-120 / 70-120 1-4

16 Branch Joint 70-120 / 25 1-4

17 Branch Joint 16 / 16 1-4

S.No. No. of Cores

* Other sizes can be prepared as per the requirments of the customers

Cores Size (Sqmm)

C l i c k H e r e t oN E X T P A G E

Page 152: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

158C l i c k H e r e t o

N E X T P A G E

Page 153: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

159

DOUBLE BRANCH / SERVICE JOINTS

Cable Specifications:

1. Conductors:Copper & Aluminium Conductors

2. Insulation & Sheathing:PVC Insulated, XLPE Insulated, PaperInsulated, PVC Sheathed Armoured orUmarmoured cables.

3. Voltage RangeUpto 1000 a.c & 1500 V d.c.

Cable Joint Kit Contents:

The kit contents encloses the following items:1. Adequate Number of Mechanical Connectors.2. Cable Joint Outer Shell (Top + Bottom + Cap).3. Armour Bonding System in case of Armoured Cables ( Earth Continuity).4. Adequate Number of Brass Gauses in case of Copper Conductors.5. Water Sealent Strip in case of PILC Cbles.

1 Double Branch Joint 500 / 2 x 95 1-42 Double Branch Joint 300 / 2 x 95 1-4

3 Double Branch Joint 300 / 2 x 300 1-4

4 Double Branch Joint 185/ 2 x 185 1-4

S.No. Cores Size (Sqmm) No. of Cores

* Other sizesx can be prepared as per the requirments of the customers

C l i c k H e r e t oN E X T P A G E

Page 154: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

160C l i c k H e r e t o

N E X T P A G E

Page 155: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

161

PILOT CABLE JOINTS

Cable Specifications:

1. Conductors:Copper & Aluminium Conductors

2. Insulation & Aluminium & Sheathing:PVC Insulated, XLPE Insulated, PaperInsulated, PVC Sheathed Armoured orUmarmoured cables.

Cable Joint Kit Contents:

The kit contents encloses the following items:

1. Adequate Number of PreinsulatedCompression Ferrules.

2, Cable Joint Outer Shell (Top + Bottom + Cap).3. Armour Bonding System in case of Armoured

Cables ( Earth Continuity).4. Screen connector Assembly.5. Water Sealant Strip.

1 16-Core Pilot Cable Joint 16

2 34-Core Pilot Cable Joint 34

S.No. Cores Size (Sqmm) No. of Cores

* Other sizes can be prepared as per the requirments of the customers

C l i c k H e r e t oN E X T P A G E

Page 156: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

162C l i c k H e r e t o

N E X T P A G E

Page 157: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

163

STREET LIGHTING JOINTS

Cable Specifications:

1. Conductors:Copper & Aluminium Conductors

2. Insulation & Sheathing:PVC Insulated, XLPE Insulated, PaperInsulated, PVC Sheathed Armoured orUnarmoured cables.

3. Voltage Range:Upto 1000 V a.c & 1500V d.c.

Cable Joint Kit Contents:

The kit contents encloses the following items:1. Adequate Number of Mechanical Connectors.2. Cable Joint Outer Shell (Top + Bottom + Cap).3. Armour Bonding System in case of Armoured

Cables (Earth Continuity)4. Adequate Number of Brass Gauses in case of Copper Conductors.5. Water Sealent Strip in case of PILC Cables.

1 Universal Joint 5x35 1-5

2 Universal Joint 3x16 1-3

S.No. Cores Size (Sqmm) No. of Cores

* Can be used either as Branch Joint & StraightOther sizes can be prepared as per the requirments of the customers

C l i c k H e r e t oN E X T P A G E

Page 158: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

164C l i c k H e r e t o

N E X T P A G E

Page 159: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

165

POT ENDS

Cable Specifications:

1. Conductors:Copper & Aluminium Conductors

2. Insulation & Sheathing:PVC Insulated, XLPE Insulated, Paper Insulated,PVC Sheathed Armoured or Unarmoured cables.

3. Voltage Range:Upto 1000V a.c & 1500V d.c.

Cable Joint Kit Contents:

The kit contents encloses the following items:1. Cable Joint Outer Shell (Top + Bottom + Cap).2. Fitting Accessories.3. Water Sealent Strip in case of PILC Cables.

1 Pot End 300 - 185 1-4

2 Pot End 240 1-4

3 Pot End 300 -150 1-4

4 Pot End 300 - 120 1-4

5 Pot End 70 - 35 1-4

6 Pot End 25 1-4

S.No. Cores Size (Sqmm) No. of Cores

* Other sizes can be prepared as per the requirments of the customers

C l i c k H e r e t oN E X T P A G E

Page 160: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

166C l i c k H e r e t o

N E X T P A G E

Page 161: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

167

BERPAK CABLE JOINTING COMPOUNDSTWO PARTS POLYURETHANEBERPAK 252 AND BERPAK 516

Product Description and Uses

Berpak 252 and Berpak 516 are free flowing materials that cure at room temperature to from tough, resilent elastomers. They are intended for use electrical jointencapsulation compounds.

Typical Application properties

Colour1-Base (Part B) Cream Fawn2-Accelerator (Part A) Brown Brown

Mixing Ratio(Part B: Part A)By Weight 100:16 6:1By Volume 100:22 5:1

Spacific GravityPart B 1.72 1.48Part A 1.23 1.23

Viscosity (@ 25ºC)Part B 30’000 cp 25’000 cpPart A 400 cp 400 cp

Flash Point Above 200ºC Above 200ºC

Non-Volatile content 99% Min 99% Min

Application Time (@ 25ºC) 20-30 Minutes 15 Minutes

Tack free Time (@ 25ºC) 60 minutes 60 Minutes

Cure Time (@ 25ºC) 24 Hours 24 hours

Property Berpak 252 Berpak 516

C l i c k H e r e t oN E X T P A G E

Page 162: Gulf Cable 2003

Gulf Cable & Electrical Ind. Co.

168

Typical Performance Properties

Colour Light brown Light Brown

Mixed Specific Gravity 1.63 1.44

Hardness 70º Shore A2 80ºC Shore A2

Tear Strength ( Die C) 30 N / mm 30 N / mm

Tensile Strength 4.8 MN /sam 8 MN / sqm

Ultimate Elongation 100% 75%

Impact Strength 8Kg.m 8 Kg.m(See C 81 Type Test) (See C 81 Type Test)

Continuous Operating 135ºC 135ºCTemperature Capability (See C81 Type test) (See C 81 Type Test)

Thermal Conductivity 0.24 WmE-1 “KE-1” 0.39 WmE-1 “KE-1”

Shrinkage During Cure < 0.1 < 0.1

Volume reistivity 1.4 x 10E7 ohm-m 5.2x10E 11 ohm-m

Dielectric Strength 8MV/m 35 MV/m

Adhesion to PVC 0.76 N/sqmm 2.25 M/sqmmabraded abraded

Adhesion XLPE 0.45 N/sqmm 2.27 N/sqmmabraded abraded

Adhesion To Lead 1.6N/sqmm 2.34 N/sqmm(Primer No.4) (Primer No.4)

Adhesion To aluminium 5.2 N/sqmm 1.1 N/sqmm(PH 354) (PH 354)

Surface Resistivity 4x10 E11 ohms 1.87 x 10 E13 ohmsDuring Cure

Property Berpak 252 Berpak 516

Application Information:

1. Mixing Informations:Do not open containers untill ready for use. Stir Part B before use.

2. Clearing of Equipment:Equipment etc., may be cleaned with Methyl EthylKetone (MEK) or Methylene Dichloride immediatelyafter use or before marterial cures. Use “RITE OFF” to remove any Cured material.

3. Packing, Shipping, Storage & Handling:Berpak Encapsulation Compounds are moisture sensitive and have a storage life of 24 months whenKept in their original unopended containers and stored at temperatures between 10-25ºC in a dry area.Containers must be kept tightly closed when not in use.

C l i c k H e r e t oH O M E

Page 163: Gulf Cable 2003

Designed & Printed by Al-Assriya Printing Press Pub. & Dist. Co. W.L.L. - KUWAITTel. : (+965) 2423543 - 2423583 Fax : (+965) 2420364

C l i c k H e r e t oN E X T P A G E

Page 164: Gulf Cable 2003

P.O. Box 1196 Safat 13012 - Safat - KUWAIT Cable : WIREGULFTel: 4675244 - 4674512 Fax: 4675305 - 4675850 Com. Reg. 23213

Email : [email protected] [email protected]

Website : www.gulfcable.com

C l i c k H e r e t oH O M E