Lighting levels for exterior sports lighting are considerably lower than daylight levels and usually lower than for the same sport played indoors. This is because there is generally greater subject contrast outdoors, with a dark sky backdrop, giving good adaptation levels. Illuminance levels are dependent upon the difficulty of the visual task.

Guide to sports lighting levels What you need to know Sports lighting brochureSports lighting

In general, fast action, a small playing object (cricket ball) and long viewing distance will require high lighting levels. A slower speed, larger playing object (football) and closer viewing distance will require lower lighting levels. Exterior sports lighting is provided to achieve either supervised training, club, national, international or CTV coverage. Various lighting guides and lighting specifications are available, recommending appropriate illuminance levels for individual sports. Within Europe, a European Standard exists covering minimum sports lighting levels EN 12193:2007. In addition many sports governing bodies also provide separate specific lighting requirements.

Most recommendations of individual sports lighting levels are divided into classes of play:

Class I - Top Level Competition.■Class II - Intermediate Level Competition.■Class III - Lower Level Competition & Supervised Training.

Lighting for CTV broadcasting has specific requirements and recommendations (CIE No.83:1989). The table below provides a selection of recommended lighting levels for principle sports in accordance with EN 12193:2007.

Guide to sports lighting levels

Search for... Search

Take me to... Go

Home > Applications > Sports lighting > Guide to sports lighting levels

Home Applications Products Services Technical Media Contact

Page 1 of 3Guide to sports lighting levels

Page 1 of 3Guide to sports lighting levels

Page 2: Guide to Sports Lighting Levels

Recommendations of Minimum Lighting Levels (Table 1)

Sport

Illuminance Level (Em. Horizontal) Lux *

(Non CTV)Glare Rating (GR)

Class I Class II Class III

Em Lux

Uo Min/ave

Em Lux

Uo Min/ave

Em Lux

Uo Min/ave I II III

Athletics 500 0.7 200 0.5 50 to 100 0.5 50 55 55

Baseball In Fld Out Fld

750 500

0.7 0.5

500 300

0.7 0.5

300 200

0.5 0.3

50 50

50 50

55 55

Basketball 500 0.7 200 0.6 75 0.5 50 50 55

Bowls (Flat Green) 300 0.7 200 0.7 100 0.5 50 50 50

Cricket Grounds

Sq Field

750 500

0.7 0.5

500 300

0.7 0.5

300 200

0.5 0.3

50 50

50 50

55 55

Equestrian 500 0.7 200 0.7 100 0.5 50 50 55

Football (soccer) 500 0.7 200 0.6 75 0.5 50 50 55

Hockey 500 0.7 200 0.7 200 0.7 50 50 55

Horse racing 200 0.6 100 0.4 50 0.2 50 50 55

Netball 500 0.7 200 0.6 75 0.5 50 50 55

Rugby 500 0.7 200 0.6 75 0.5 50 50 55

Tennis 500 0.7 300 0.7 200 0.6 50 50 55

Volleyball 500 0.7 200 0.6 75 0.5 50 50 55

* Em is the Maintained Illuminance Level (specification level) and is the design illuminance level, below which the lighting should not be allowed to fall during the period to planned maintenance. Whilst every endeavour is undertaken to provide accurate information, Abacus Lighting recommends that the relevant sport guides and standards or the appropriate individual sport governing body be consulted to ensure full compliance with requirements. Caution: Lighting specifications for locations outside UK may differ from those stated on this web site.

Page 2 of 3Guide to sports lighting levels

Page 2 of 3Guide to sports lighting levels

Page 3: Guide to Sports Lighting Levels

Home About Abacus History and people Recruitment News Facebook Twitter Abacus Lighting China Abacus Lighting Russia

Applications Airports Ports Amenity and architectural Car park Sport Industrial and commercial Education and BSF Road and rail Wind energy Telecommunications

Products Amenity and architectural lighting Sports and area floodlights Car park and road lighting LED lighting Columns, base-hinged and fixed High mast systems Telescopic masts

Services Design Installation Maintenance Training Bespoke structures Fabrication services Technical Photometry Brochure library

Media News Movies Facebook Twitter feed Contact Head office Abacus Worldwide Telephone +44 (0)1623 511 111 Email [email protected]

0

Page 3 of 3Guide to sports lighting levels

Page 3 of 3Guide to sports lighting levels