GSM Plug-in with Data Plan for North America...Cellular Internet Connectivity for Commercial...
Transcript of GSM Plug-in with Data Plan for North America...Cellular Internet Connectivity for Commercial...
Cellular Internet Connectivity for Commercial Installations Connects SolarEdge inverters wirelessly to the Internet No need for Internet infrastructure at site Installed in inverter Enablesremoteanalysisandtroubleshooting Supportshighbandwidthmonitoringofinverters,optimizers,metersandweatherstations Futureproofsolution
www.solaredge.usUSA - CANADA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - AUSTRALIA - THE NETHERLANDS - UK - ISRAEL - TURKEY - SOUTH AFRICA - BULGARIA - INDIA
COM
MU
NIC
ATIO
N
GSM Plug-in with Data Plan for North America SE-GSM-R05-US-S4 / SE-GSM-R05-NA-S4
GSM Plug-in with Data PlanFor North America SE-GSM-R05-US-S4 / SE-GSM-R05-NA-S4
COMPATIBLE INVERTERS SEXXXXX-XXXXXNXXX
FUNCTIONAL SE-GSM-R05-XX-S4(1) UNIT
Supported Systems Commercial systems up to 500kW DC(2)
Monitoring Continuousconnectionwith5minutetelemetryfromallconnecteddevices
Number of Monitored Inverters with a Single GSM Plug-in Upto32,limitedbythesystemDCsize(2)
PlanDuration 5 years
Per-invertercellularconnectioncharges(3)
SE-GSM-ICC-US-S1-InverterCellularConnection,0-500kWSE-GSM-ICC-US-S2-InverterCellularConnection,500kW-1,000kW
SE-GSM-ICC-US-S3-InverterCellularConnection,1,000kW-1,500kWSE-GSM-ICC-US-S4-InverterCellularConnection,1,500kW-2,000kW
SE-GSM-ICC-US-S5-InverterCellularConnection,2,000kW-UpRF PERFORMANCE
OperatingFrequencyMin.-Max.850Modemtransmit:824-849
MHzModemreceive:869-894
OperatingFrequencyMin.-Max.1900Modemtransmit:1850-1910
MHzModemreceive:1930-1990
Antenna Included, 2dBi outdoor; Dualbandantenna:824-960MHz/1710-2170MHz
Maximumoutputpower:850MHzband 33 dBm
Maximumoutputpower:1900MHzband 30 dBmReceiverInputSensitivity(Downlink RF level @ BER Class II < 2.4 % ) Typical-109 dBm
STANDARD COMPLIANCE
Emissions and Radio FCCCFRTitle47Part15ClassB,Part15.247
INSTALLATION SPECIFICATIONS
Dimensions(LxW) 3.55x1.35/90.5x34.5 in/mm
OperatingTemperature -40to+185/-40to+85 °F/°C(1) XX = NA for data plans in Canada, XX = US for data plans in the USCustomerisresponsibleforverifyingthattheregionofinstallationiscoveredbythe3GGSMnetworkpriortoanyinstallationbyaccessing:http://aeris.cellmaps.com/?instance=globalSolarEdgeshallnotberesponsibleorliableforunavailabilityordiscontinuanceofnetworkcoverageinaspecificareaorregionoranynetworkdowntime.(2) Forlargersystems,usemultipleGSMPlug-ins(3) Foraccuratepricing,pleasecontactyourlocalCustomerSupportRepresentative(CSR)
© SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are
trademarks of their respective owners. Date: 04/2018/V01/ENG NA. Subject to change without notice.
Single or Multiple Inverters
RS485-1 RS485-1 RS485-1 RS485-E
L1L2L3