Transcript of GSM BSC Maintenance
HUAWEI TECHNOLOGIES CO., LTD.
All rights reserved
www.huawei.com
Internal
OMD000201 GSM BSC Maintenance Console
ISSUE 4.0
HUAWEI TECHNOLOGIES CO., LTD. Page 2All rights reserved
References
M900/M1800 Base Station Controller
Routine Operation Manual
M900/M1800 Base Station ControllerT
echnical Manual
HUAWEI TECHNOLOGIES CO., LTD. Page 3All rights reserved
Chapter 1 Checking Equipment StatusChapter 1 Checking Equipment Status
Chapter 2 Locating FaultsChapter 2 Locating Faults
HUAWEI TECHNOLOGIES CO., LTD. Page 4All rights reserved
Operations on Maintenance Console
Checking equipment status
Operation status of modules
Operation status of boards
CPU occupations status
Status of CCS7 links
Status of LAPD links
Status of circuits
HUAWEI TECHNOLOGIES CO., LTD. Page 5All rights reserved
Operation Status of Modules
Access: [Maintenance/Module State]
Functions: display the communication state
between the maintenance console and
each BM of the BSC
Results:
in normal conditions, module numbers
will be displayed.
If the communication is faulty, a * will be
placed before the module.
HUAWEI TECHNOLOGIES CO., LTD. Page 6All rights reserved
Operation Status of Boards
Access: [control/Equipment]
Functions: view and query board state and information, reset board
Results :
in normal conditions, boards on the interface are in grey, green
(active) and blue (standby).
if the board is faulty, color shown on the panel will change to red.
Caution: if you find a board is in red, first you should confirm it has been configured or not, then for GALM in AM you should check whether connectedalarmbox has been powered on.
HUAWEI TECHNOLOGIES CO., LTD. Page 7All rights reserved
Checking Equipment Status
HUAWEI TECHNOLOGIES CO., LTD. Page 8All rights reserved
Query MPU
HUAWEI TECHNOLOGIES CO., LTD. Page 9All rights reserved
Query GCKS
HUAWEI TECHNOLOGIES CO., LTD. Page 10All rights reserved
CPU Occupation Status
Access: [trace/occupation ratio]
Functions: by viewing CPU occupation ratio, the BSC load
condition (Normal, Overload and Congestion) can be known.
Results:
In normal conditions, the occupation status of CPU and
memories should be displayed in the system performance
tracing window. When the bar chart is blue, the status is
normal.
If the bar chart is yellow, the status is overloaded and red,
congested.
HUAWEI TECHNOLOGIES CO., LTD. Page 11All rights reserved
View CPU Usage and State of BM Modules
HUAWEI TECHNOLOGIES CO., LTD. Page 12All rights reserved
Status of CCS7 Links Access: [SS7 Maintenance/State Query]
Functions: query the signaling link state, destination state and r
oute state to ensure the interworking of inter-office SS7
Interface:
Module number
Link number
HUAWEI TECHNOLOGIES CO., LTD. Page 13All rights reserved
Query Input Parameters
Data configuration \ view data configuration work mode \
Module 0 \ Hardware \ [E3M Board property]
HUAWEI TECHNOLOGIES CO., LTD. Page 14All rights reserved
Query Result
In normal conditions
HUAWEI TECHNOLOGIES CO., LTD. Page 15All rights reserved
Status of LAPD Links
Access: [Control\LAPD Link Maintenance]
Functions: query LAPD link to check current link state
Interface:
Module number
Start link no, end link no
HUAWEI TECHNOLOGIES CO., LTD. Page 16All rights reserved
Query Input Parameters
Data management\site\[site description table]---OML
HUAWEI TECHNOLOGIES CO., LTD. Page 17All rights reserved
Query Input Parameters
Data management\local-office\[TRX configuration table]---RSL
HUAWEI TECHNOLOGIES CO., LTD. Page 18All rights reserved
Query Results
In normal conditions, the query result should be multi frame
establish state
If TEI has not allocate state, the link has not been configured; If
TEI has allocated state, the link has been configured, but board
is not inserted; if off-link state, the established link is
disconnected and system cannot operate at that time. Or the
link is configured and board is inserted, but they are not
connected to the BTS
HUAWEI TECHNOLOGIES CO., LTD. Page 19All rights reserved
GLAP Link Query Results
HUAWEI TECHNOLOGIES CO., LTD. Page 20All rights reserved
Circuit Status
Access: [ control\circuit\circuit state]
Functions: query the state of channel of TC, BIE and PBIE circuits
Interface:
Module number
Circuit type
Start channel, end channel
HUAWEI TECHNOLOGIES CO., LTD. Page 21All rights reserved
Query Results
In normal conditions, state should be uninstalled, idle and busy
HUAWEI TECHNOLOGIES CO., LTD. Page 22All rights reserved
Chapter 1 Checking Equipment StatusChapter 1 Checking Equipment Status
Chapter 2 Locating FaultsChapter 2 Locating Faults
HUAWEI TECHNOLOGIES CO., LTD. Page 23All rights reserved
Operations on Maintenance Console
Locating faults
Interface tracing
Signaling tracing
Switchover
Board resetting
Module resetting
HUAWEI TECHNOLOGIES CO., LTD. Page 24All rights reserved
Interface Tracing
Access: [trace\GSM interface trace]
Functions: trace messages on A-bis, Um and A interfaces in re
al time
interface:
Interface type
Module No.
HUAWEI TECHNOLOGIES CO., LTD. Page 25All rights reserved
A Interface Message Trace
Filter conditions:
connectionless message, DTAP message, BSSMAP
SCCP No.
HUAWEI TECHNOLOGIES CO., LTD. Page 26All rights reserved
A Interface Message Trace
HUAWEI TECHNOLOGIES CO., LTD. Page 27All rights reserved
A-bis Interface Message Trace
Filter conditions:
BTS number, TRX number, Channel number
Measurement report, wireless link layer management message, special channel management message, common channel management message, TRX management message
HUAWEI TECHNOLOGIES CO., LTD. Page 28All rights reserved
A-bis Interface Message Trace
HUAWEI TECHNOLOGIES CO., LTD. Page 29All rights reserved
Um Interface Message Trace
Filter conditions:
BTS number, TRX number, Channel number
Radio resource management message, MM mobility management
message, Call control and related Supplementary Services
message, Unrelated Supplementary Service message, SMS short
message
HUAWEI TECHNOLOGIES CO., LTD. Page 30All rights reserved
Um Interface Message Trace
HUAWEI TECHNOLOGIES CO., LTD. Page 31All rights reserved
Save Tracing Message
HUAWEI TECHNOLOGIES CO., LTD. Page 32All rights reserved
GSM Trace Review
HUAWEI TECHNOLOGIES CO., LTD. Page 33All rights reserved
Signaling Tracing
Access: [SS7 maintenance\SS7 message trace]
Functions: trace message of a signaling link, capture and save
all or partial message through the signaling link
Interface:
Message type
Filter
Parameter
Save to file
HUAWEI TECHNOLOGIES CO., LTD. Page 34All rights reserved
SS7 Message Trace
HUAWEI TECHNOLOGIES CO., LTD. Page 35All rights reserved
SS7 Trace Review
HUAWEI TECHNOLOGIES CO., LTD. Page 36All rights reserved
Switchover
Access: [control\immediate switchover]
Functions: when the active board is faulty or the data of
active/standby boards are inconsistent, if the boards have not
switched over automatically, it is required to switch over the
active and standby boards immediately, making the normal
board use the correct data and ensure the correctness of the
BSC operational data. After the active and standby boards are
switched over immediately, the original standby board will
become the active board while the original active board
become the standby board
HUAWEI TECHNOLOGIES CO., LTD. Page 37All rights reserved
Switchover
Interface
Switchover board type
Module number
HUAWEI TECHNOLOGIES CO., LTD. Page 38All rights reserved
Switchover
HUAWEI TECHNOLOGIES CO., LTD. Page 39All rights reserved
Board Resetting
Access: [control\equipment]
Functions: resetting operations are be performed when some
boards are faulty. Resetting results include “successful reset”,
“equipment fault”, ”uninstalled”, “the device can’t be reset” or
“unexecuted”
Caution:This operation requires the system setup authority. Do not reset a board unless it is necessary.
HUAWEI TECHNOLOGIES CO., LTD. Page 40All rights reserved
Board Resetting
HUAWEI TECHNOLOGIES CO., LTD. Page 41All rights reserved
Module Resetting
Access: [control\hierarchical reset]
Functions: mainly used to load some modified data that can not
be set online, or as a way of recovery when any problem
occurs during BSC running
Caution:Hierarchical reset operation requires system setting authority. This operation may affect system services. Do not perform this operation unless it is necessary.
HUAWEI TECHNOLOGIES CO., LTD. Page 42All rights reserved
Module Resetting Interface
Restart level Module number
HUAWEI TECHNOLOGIES CO., LTD. Page 43All rights reserved
In this course ,we have learned how to
Check equipment status
Locate faults
Trace interface
Switchover and reset boards
SummarySummary
www.huawei.com
Thank You