GSB Library Atrium Analysis
John BrooksRichard JonesReid SenescuMin Jae SuhMatt Yamasaki
![Page 2: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/2.jpg)
Options
Base
No Basement Skylights
Alternate
Basement Skylights
![Page 3: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/3.jpg)
Options
Base
No Basement Skylights
Alternate
Basement Skylights
![Page 4: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/4.jpg)
Potential Advantages of SkylightPlus Minus
Structure None expected Other beams bigger.Larger lateral deflections.More complex gravity framing
Energy More natural ventilation, less cooling load
Bigger temp. difference between bottom and top of libraryLess insulation, could create more heating/cooling load
Lighting More daylighting, .less energy Potential glare, sunshine on books
Acoustics None expected Louder, less sound absorbing material
CFD Nat. Ventilation better in the summer
Airflow from doors could decrease comfort in winter
Cost Lower life cycle cost Higher first cost, because of less homogenous design
Schedule None expected Added scope, longer duration
![Page 5: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/5.jpg)
Outline1. Structure 2. Lighting3. Acoustics4. Schedule, 4D5. Cost6. Energy Analysis7. CFD8. Sample Money Slide9. Challenges and Resolutions
For each tool:a) Assumptionsb) Metricsc) Results
![Page 6: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/6.jpg)
6
Static Load Conditions• Dead Load• Live Load• Earthquake
IBC 2006: Inputs are fixed.
• WindASCE 7-02 Wind LoadingApplied to all area objectsWind speed = 100 mphUnknown Inputs: importance factor, exposure type,
topographical factor, gust factor, directionality factor
![Page 7: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/7.jpg)
7
Model Analysis• Analysis Goal
Determine maximum moments & deflections under given loading conditions
Determine demand capacity ratios for all members
• Analysis ParameterDimensions of membersJoints: ReleasesMaterialsLoads: Load combinations
![Page 8: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/8.jpg)
8
Revit Structure• Regenerate Revit Architecture model
![Page 9: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/9.jpg)
9
ETABS
• Import Revit model• Correct geometric errors• Define “dummy surfaces”• Define additional load parameters &
combinations• Analyze
![Page 10: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/10.jpg)
10
Analysis Result
• ETABS generates shear, moment, deflection and demand capacity data on structure.
![Page 11: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/11.jpg)
11
Earthquake Displacements
• Displacements in original design due to earthquake are excessive.
• Possibly due to invalid inputs.
![Page 12: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/12.jpg)
12
Design Check
• Numerous failures of structural members in original design.
• Possibly due to invalid inputs.
![Page 13: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/13.jpg)
Lighting - Occupant Behavior
• Occupied 8 AM to 5 PM• Min. Illuminance: 500 lux• Active and Passive light switching and blind use• Manual on/off switch near door• Installed lighting power density 1.5 W/SF
![Page 14: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/14.jpg)
Lighting – Analysis Assumptions
• Time Step: 30 minutes• Ground Reflectance: 0.2
![Page 15: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/15.jpg)
Lighting – MetricsUnits Measurement -3 0 3
Daylighting Aesthetics
unitless My opinion Claustro-phobic
ok beautiful
Lighting Cost
Dollars / SF
Energy $3410 $1746 $737
Lighting Quality
% of sensors
Continuous Daylight Factor > 40%
0% 40% 90%
![Page 16: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/16.jpg)
16
Skylights provide more light…Annual Light Exposure (lux hours)
Base
No Basement Skylights
Alternate
Basement Skylights
![Page 17: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/17.jpg)
Not much direct light…
Alternate
Basement Skylights
December 21, 2008, 2:00 PM
![Page 18: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/18.jpg)
Lighting ResultsFor Base and Alternate:• Total Electric Lighting Energy: 3.5 kWh/SF
– Average Office Building Energy: 2.6 kWh/SF
• Daylight Autonomy: 0%– % of the year when a minimum illuminance threshold is met
by daylight alone
• 0% of sensors have Daylight Factor > 2%– ratio of internal to external illuminance.
Base Alternate
% of sensors with Continuous Daylight Autonomy >40%
0% 11%
![Page 19: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/19.jpg)
Next StepsFor Base and Alternate:• Total Electric Lighting Energy: 3.5 kWh/SF
– Average Office Building Energy: 2.6 kWh/SF
• Daylight Autonomy: 0%– % of the year when a minimum illuminance threshold is met
by daylight alone
• 0% of sensors have Daylight Factor > 2%– ratio of internal to external illuminance.
Base Alternate
% of sensors with Continuous Daylight Autonomy >40%
0% 11%
WHY?
WHY?
WHY?
![Page 20: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/20.jpg)
21
Information• Goal
What is a different acoustics after designing 3 skylights on the ground floor & basement? (Influence of 3 skylights to the ground floor & basement)
• Models Baseline: Original GSB Atrium Option: GSB Atrium with 3 skylights on the ground floor
• Metrics Two different models (Base vs. Option) Each different volume and surface of models
(2,735m³ vs. 5,270m³ )
![Page 21: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/21.jpg)
22
Assumption• Material Condition (Fixed)
• No influence from outside weather and noise
![Page 22: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/22.jpg)
Assumption(Cont)• Sound Condition
Setup 1 speaker instead of noise for the each analysis
• No influence from existing the upper floors or not• No influence of the components and equipments except 50 clothe-covered chairs• Twice bigger volume due to the skylights in option• Consider only Sabine Algorithm for Reverberation time
![Page 23: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/23.jpg)
Base vs. Option
• Sound Path (Low Frequency: 63Hz)
BASE: 21.7ms OPTION: 18.5ms
![Page 24: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/24.jpg)
Base vs. Option(Cont)
• Sound Path (High Frequency: 16KHz)
BASE: 17.4ms Option: 15.7ms
![Page 25: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/25.jpg)
Base vs. Option(Cont)
• Base Reverberation Time
![Page 26: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/26.jpg)
Base vs. Option(Cont)
• Option Reverberation Time
![Page 27: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/27.jpg)
Base vs. Option(Cont)
• Base Acoustic Response
16KHz: 47ms
63Hz: 47ms
![Page 28: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/28.jpg)
Base vs. Option(Cont)
• Option Acoustic Response
63Hz: 89ms
16KHz: 95ms
![Page 29: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/29.jpg)
Base vs. Option(Cont)
• Result63Hz
16KHz
Base OptionElapsed Time 21.7ms 18.5msSound Type Direct/Masked Direct/Masked
Base OptionElapsed Time 17.4ms 15.7ms
Sound Type Direct/Masked Direct/Masked
![Page 30: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/30.jpg)
Base vs. Option(Cont)
• ResultBase Option
RT Value 500ms~690ms 950ms~1150
Ideal RT Value 800ms~1750ms 1000ms~1900ms
Estimated Decay
63Hz: 47ms 63Hz: 89ms
16KHz: 47ms 16KHz: 95ms
![Page 31: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/31.jpg)
Conclusion• The RT of option model is in the ideal pink area, but the RT of
base model is below the area. The volume and surface of base model is easy to absorb the sound
rays.• There is no influence by 3 skylights to the basement• 3 Skylights change the result a little bit, but make a better
acoustic condition at the ground floor. Better RT result
• The base model has a longer elapsed time to completely disappear.
• The volume and the surface area bring a big different criteria for ideal condition. Ideal Pink Area: 800ms~1750ms vs. 1000ms~1900ms
![Page 32: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/32.jpg)
For the next step
• Simulate the model with several different noise directions.
• Figure out the scale of preference about estimated decay time
• Find out other metrics to achieve a better result.
![Page 33: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/33.jpg)
Costs, Schedule
![Page 34: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/34.jpg)
Assumptions
• Building Explorer is right– U.S. Average Building Index ok– Automatically generated schedule ok
![Page 35: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/35.jpg)
Results
Cost Breakdown
Material81%
Labor19%
Equipment0%
Material
Labor
Equipment
![Page 36: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/36.jpg)
Material Costs
![Page 37: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/37.jpg)
Labor Costs
$2081.36
![Page 38: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/38.jpg)
Equipment Costs
$33.82
![Page 39: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/39.jpg)
Schedule + 4D
4-Day Duration…
![Page 40: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/40.jpg)
Day 1
![Page 41: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/41.jpg)
Day 2
![Page 42: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/42.jpg)
Day 3
![Page 43: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/43.jpg)
Day 4
![Page 44: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/44.jpg)
Energy Analysis
• Goal:– To determine energy consumption of building– To determine if natural ventilation will be
sufficient
![Page 45: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/45.jpg)
Energy Analysis
• IES Virtual Environment– ApacheSim
• Simulates natural and mixed ventilation (MacroFlo)• Simulates building loads (ApacheLoad)• Simulates heat loss/gain (ApacheCalc)
![Page 46: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/46.jpg)
Energy Analysis
• Assumptions:– Model inputs
• HVAC System: Mixed System w/ natural ventilation• Weather file: Moffett Field, Mountain View, CA• Building type: Library• Building construction: default room system• Thermal condition: Atrium Each Floor
– Fluorescent lighting – 1.5W/SF– People 65 from 10am-12am
– Simulation• Run period: 1 May to 31 May• Time step: 10 minutes• Report interval: 60 minutes• Preconditioning: 10 days
![Page 47: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/47.jpg)
Energy Analysis Results
• Carbon Emissions
CO2 emissions – base case
Total monthly emissions – 35,027 lbCO2
CO2 emissions – alternative case
Total monthly emissions – 46,587 lbCO2
![Page 48: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/48.jpg)
Energy Analysis Results
• Energy Consumption
Energy Consumption – Base case
Monthly total – 146.053 MMBtuEnergy Consumption – Alternative case
Monthly total – 206.327 MMBtu
![Page 49: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/49.jpg)
Energy Analysis Results
• Heating/Cooling Loads
Daily Heating and Cooling Loads – base case
Monthly total – heating: 31.088 MMBtu; cooling: 0MMBtu
Daily Heating and Cooling Loads - alternative
Monthly total – heating: 49.844MMBtu; cooling: 34.202MMBtu
![Page 50: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/50.jpg)
Energy Analysis Results
• Room analysis – StacksPeak hourly room loads
Base Case Alternative Case
Room environmental conditions
![Page 51: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/51.jpg)
Energy Analysis
• Next Step– More accurately capture behavior of building
• Determine actual operating hours• Determine actual HVAC system
– Type, set points, etc
• Create more accurate geometry
![Page 52: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/52.jpg)
CFD Analysis
• CFD: Computational Fluid Dynamics– Analysis of fluid flows using numerical methods
and algorithms– Simulation of wind tunnel performance
![Page 53: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/53.jpg)
CFD Analysis
IES Virtual Environment• MicroFlo (IES VE)
• Numerical simulation of air flow an heat transfer
• User definable obstructions• Interoperability with Virtual
Environment model
![Page 54: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/54.jpg)
CFD Analysis
• Goals:– Determine effects of atrium on airflow in building– Predict occupant comfort
• Temperature gradient in rooms• Air velocity
![Page 55: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/55.jpg)
CFD Analysis
• Model inputs:– Boundary Conditions defined during energy
analysis– Obstructions and heat generating component
• Ex: People, computers, radiators, etc
• Model outputs:– Air flow temperature, direction, and velocity– Graphical displays of temperature gradient and air
flow properties
![Page 56: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/56.jpg)
CFD Analysis
• Progress– Problems with
importing gbXml geometry
• Inconsistencies developed between Revit and IES
![Page 57: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/57.jpg)
CFD Analysis
• Next Step– Manipulate Revit model to properly represent
geometry in IES• Contact with IES tech support as well as Ben
Welle
![Page 58: GSB Library Atrium Analysis John Brooks Richard Jones Reid Senescu Min Jae Suh Matt Yamasaki.](https://reader037.fdocuments.in/reader037/viewer/2022103022/56649cfa5503460f949cc8cc/html5/thumbnails/58.jpg)
Sample MACDADI Goodness