Group #37829 IFB #23055 - Attachment 08: Nucor … · nucor steel, marion inc. 1 4 4 6 posts shall...

9
ISSUED UNDER EFFECTIVE: 05/02/2006 THESE DETAILS ARE SKETCH DRAWINGS AND ARE NOT TO SCALE EB 06-021 TABLE 1 : POST PROPERTIES & DIMENSIONS MOMENT * 2.00 lb/ft 0.56 0.16 0.20 1.462 3.062 1.278 0.122 0.105 1092 ft-lbs A B C D E A B E C D EMBEDMENT DETAILS 3 3 3 FLAT LAP-SPLICE MODERATE STEEP YES YES YES NO NO NO POST SIZE EMBEDMENT TYPE SOIL SLOPE S - 1 NON-PLASTIC (MED TO VERY COMPACT) SOIL DESCRIPTION S - 2 NON-PLASTIC (LOOSE TO VERY LOOSE) MIN. EMBEDMENT SOIL p SOIL p SIGN POSTS SHALL BE PUNCHED THEIR FULL LENGTH WITH 3/8" d HOLES ON 1" CENTERS. MIN. EMBEDMENT S-2 INCLUDES UNIFORM SANDS WHICH EXHIBIT PENETRATION VALUES OF LESS THAN 9 BLOWS PER FOOT USING A 300 LB. DROP HAMMER. BEACH SANDS ARE INCLUDED IN THIS CATEGORY 2 4 I (in ) 3 S (in ) ALL GALVANIZING AND GALVANIZING REPAIRS SHALL BE DONE IN ACCORDANCE WITH y719-01,TYPE III. 4.00 lb/ft 1.11 0.47 0.47 1.968 3.500 1.336 0.272 0.143 2615 ft-lbs 0.84 3.00 lb/ft 0.38 0.34 1.881 3.500 1.336 0.185 0.126 1904 ft-lbs 2.50 lb/ft 0.70 0.21 0.25 1.516 3.062 1.278 0.176 1394 ft-lbs 0.117 2.75 lb/ft 0.76 0.23 0.27 1.536 3.062 1.278 0.196 1512 ft-lbs 0.121 3 3 3 NOTE: THREE POSTS ALLOWED WITHIN 7 FT SWATH THREADED BAR SPACER 3/4 x 3/8 x 5" LONG SILVER-COLORED, USE ON 2.75 LB/FT AND LIGHTER POSTS 3/4 x 1/2 x 5" LONG GOLD-COLORED, USE ON 3.00 LB/FT AND HEAVIER POSTS INSTALL ON BOLT SHANKS TORQUE APPROX. 20 FT-LBS. BASE POST LENGTH, L BOLT HOLES AT 1" FROM EDGE 12 x 6 x 6" DEEP 1/8" THICK STEEL SOIL PLATE MOUNTING HEIGHT CENTROIDAL AXIS OF SIGN PANEL ASSEMBLY 4" MAX. STUB PROJECTION 5 TO 6" OVERLAP BASE POST SIGN POST TABLE 2: MAXIMUM NUMBER OF POSTS WITHIN 7 FT. SWATH MAX NO. OF POSTS MAX NO. OF POSTS BASE POSTS SHALL BE DRIVEN TO 38" MINIMUM EMBEDMENT (SEE TABLE 2 ); A MAXIMUM OF 4" MAY PROTRUDE ABOVE THE SURROUNDING GROUND SURFACE. REDUCE MOMENT CAPACITY BY 25% TO ACCOUNT FOR TORSION EFFECTS IN OPEN CROSS-SECTION SINGLE POST INSTALLATIONS. * LAP SPLICE NUTS AND BOLTS SHALL BE M180, WITH AN ULTIMATE TENSILE STRENGTH OF 180 KSI, MIN. BASE POSTS DAMAGED OR DEFORMED IN THE SPLICE CONTACT AREA SHALL BE REPAIRED OR REPLACED A.O.B.E. AT NO ADDITIONAL COST TO THE STATE. DRIVE CAPS ARE REQUIRED. BASE POSTS SHALL BE PUNCHED WITH A MINIMUM OF THIRTY-SIX 3/8" d HOLES ON 1" CENTERS (TO ACCOMODATE OPTIONAL SOIL PLATE) WITH THE FIRST HOLE 1" FROM THE TOP. SIGN POST IF LESS THAN 3/4" USE 2ND & 6TH HOLES INSTEAD OF 1ST & 5TH IF LESS THAN 3/4" USE 2ND & 6TH HOLES INSTEAD OF 1ST & 5TH 5/16" HEAD BOLT NUTS AND HEAVY DUTY LOCK WASHERS (OR GRADE C FLANGED LOCKNUTS) 5/16"- 18 UNC x 1.5" HEX HEAD BOLT AND FLAT WASHER TORQUE 20 FT-LBS. SOIL SLOPES HORIZONTAL 1 2 3 4 5 UNSTABLE STEEP MODERATE FLAT VERTICAL 1 AREA (in ) 38 54 60 60 60 60 BASE POST EMBEDMENT DEPTH 38" MINIMUM VARIES WITH SLOPE SEE TABLE 2 STATE OF NEW YORK DEPARTMENT OF TRANSPORTATION REVISION: , DIMENSIONS ARE IN INCHES UNLESS OTHERWISE NOTED 05-MAY-2006 14:21 FILE NAME = DATE/TIME = USER = afrank IP_PWP:dms61672\MARION_E_STD1_SHEET1.DGN SHEET OF MATERIALS DETAILS FOR TYPE A SIGN SUPPORTS MD645E-MRB-01 U CHANNEL SIGN SUPPORTS NUCOR STEEL, MARION INC. 4 1 4 6 POSTS SHALL BE PRODUCED FROM HIGH STRENGTH BILLET STEEL, GRADE 80-SP. CHEMICAL PROPERTIES OF THE STEEL SHALL CONFORM TO ASTM A-1 AND PHYSICAL PROPERTIES SHALL CONFORM TO ASTM A-499 (SEE TABLE 1 ). POSTS SHALL BE HOT-DIP GALVANIZED AFTER FABRICATION IN ACCORDANCE WITH ASTM A-123. SPLICE HARDWARE SHALL BE AS SUPPLIED OR RECOMMENDED BY THE MANUFACURER, EITHER ZINC-PLATED PER ASTM B-633 (MINIMUM 0.315 MIL COATING THICKNESS) OR CADMIUM PLATED ACCORDING TO ASTM B-766 (CLASS B). THE GEOTECHNICAL ENGINEERING BUREAU AND THE STRUCTURES DIVISION SHOULD BE CONTACTED WHEN A POST IS TO BE PLACED IN A PLASTIC (SOFT CLAY OR ORGANIC) DEPOSIT, OR WHEN THE GROUNDWATER ELEVATION IS WITHIN THE MINIMUM EMBEDMENT. AN S-1 SOIL CONDITION SHOULD BE ASSUMED. S-1 INCLUDES SANDS, GRAVELS AND SILTS (AND THEIR MIXTURES) WHICH EXHIBIT PENETRATION VALUES OF 9 OR MORE BLOWS PER FOOT USING A STANDARD 300 LB. DROP HAMMER AND AN 18 INCH FALL. SHOULDER MATERIALS ARE INCLUDED IN THIS CATEGORY. 7 FT. MAX STANDARD CAPACITY Group #37829 IFB #23055 - Attachment 08: Nucor Steel, Marion Inc.

Transcript of Group #37829 IFB #23055 - Attachment 08: Nucor … · nucor steel, marion inc. 1 4 4 6 posts shall...

ISSUED UNDER

EFFECTIVE:

05/02/2006

THESE DETAILS ARE SKETCH DRAWINGS AND ARE NOT TO SCALE

EB 06-021

TABLE 1 : POST PROPERTIES & DIMENSIONS

MOMENT *

2.00 lb/ft 0.56 0.16 0.20 1.462 3.062 1.278 0.122 0.105 1092 ft-lbs

A B C D E

A

B

E

C

D

EMBEDMENT DETAILS

3

3

3

FLAT

LAP-SPLICE MODERATE

STEEP

YES

YES

YES

NO

NO

NO

POST

SIZE

EMBEDMENT

TYPE

SOIL

SLOPE

S - 1

NON-PLASTIC

(MED TO VERY COMPACT)

SOIL DESCRIPTION

S - 2

NON-PLASTIC

(LOOSE TO VERY LOOSE)

MIN.

EMBEDMENTSOIL p SOIL p

SIGN POSTS SHALL BE PUNCHED THEIR FULL LENGTH WITH 3/8" d HOLES ON 1" CENTERS.

MIN.

EMBEDMENT

S-2 INCLUDES UNIFORM SANDS WHICH EXHIBIT PENETRATION VALUES OF LESS THAN 9 BLOWS PER

FOOT USING A 300 LB. DROP HAMMER. BEACH SANDS ARE INCLUDED IN THIS CATEGORY

2 4

I

(in )3

S

(in )

ALL GALVANIZING AND GALVANIZING REPAIRS SHALL BE DONE IN ACCORDANCE WITH y719-01,TYPE III.

4.00 lb/ft 1.11 0.47 0.47 1.968 3.500 1.336 0.272 0.143 2615 ft-lbs

0.843.00 lb/ft 0.38 0.34 1.881 3.500 1.336 0.185 0.126 1904 ft-lbs

2.50 lb/ft 0.70 0.21 0.25 1.516 3.062 1.278 0.176 1394 ft-lbs0.117

2.75 lb/ft 0.76 0.23 0.27 1.536 3.062 1.278 0.196 1512 ft-lbs0.121

3

3

3

NOTE: THREE POSTS ALLOWED WITHIN 7 FT SWATH

THREADED BAR SPACER

3/4 x 3/8 x 5" LONG

SILVER-COLORED, USE ON

2.75 LB/FT AND LIGHTER POSTS

3/4 x 1/2 x 5" LONG

GOLD-COLORED, USE ON

3.00 LB/FT AND HEAVIER POSTS

INSTALL ON BOLT SHANKS

TORQUE APPROX. 20 FT-LBS.

BA

SE

PO

ST

LE

NG

TH

, L

BOLT HOLES AT

1" FROM EDGE

12 x 6 x 6" DEEP

1/8" THICK STEEL

SOIL PLATE

MOUNTING

HEIGHT

CENTROIDAL AXIS OF

SIGN PANEL ASSEMBLY

4" MAX. STUB

PROJECTION

5 TO 6"

OVERLAP

BASE

POST

SIGN

POST

TABLE 2: MAXIMUM NUMBER OF POSTS WITHIN 7 FT. SWATH

MAX NO.

OF POSTS

MAX NO.

OF POSTS

BASE POSTS SHALL BE DRIVEN TO 38" MINIMUM EMBEDMENT (SEE TABLE 2 ); A MAXIMUM OF 4"

MAY PROTRUDE ABOVE THE SURROUNDING GROUND SURFACE.

REDUCE MOMENT CAPACITY BY 25% TO ACCOUNT FOR TORSION EFFECTS IN OPEN CROSS-SECTION SINGLE POST INSTALLATIONS.*

LAP SPLICE NUTS AND BOLTS SHALL BE M180, WITH AN ULTIMATE TENSILE STRENGTH OF 180 KSI, MIN.

BASE POSTS DAMAGED OR DEFORMED IN THE SPLICE CONTACT AREA SHALL BE REPAIRED OR REPLACED

A.O.B.E. AT NO ADDITIONAL COST TO THE STATE. DRIVE CAPS ARE REQUIRED.

BASE POSTS SHALL BE PUNCHED WITH A MINIMUM OF THIRTY-SIX 3/8" d HOLES ON 1" CENTERS

(TO ACCOMODATE OPTIONAL SOIL PLATE) WITH THE FIRST HOLE 1" FROM THE TOP.

SIGN POST

IF LESS THAN 3/4"

USE 2ND & 6TH HOLES

INSTEAD OF 1ST & 5TH

IF LESS THAN 3/4"

USE 2ND & 6TH HOLES

INSTEAD OF 1ST & 5TH

5/16" HEAD BOLT NUTS

AND HEAVY DUTY LOCK

WASHERS (OR GRADE C

FLANGED LOCKNUTS)

5/16"- 18 UNC x 1.5"

HEX HEAD BOLT AND

FLAT WASHER

TORQUE 20 FT-LBS.

SOIL SLOPES

HORIZONTAL

1 2 3 4 5

UNSTABLE STEEP MODERATE FLAT

V

ER

TIC

AL

1

AREA

(in )

38

54

60

60

60

60

BASE

POST

EMBEDMENT DEPTH

38" MINIMUM

VARIES WITH SLOPE

SEE TABLE 2

STATE OF NEW YORK

DEPARTMENT OF TRANSPORTATION

REVISION: ,

DIMENSIONS ARE IN INCHES UNLESS OTHERWISE NOTED

05

-MA

Y-2

00

6 1

4:2

1

FIL

E N

AM

E =

DA

TE

/TIM

E =

US

ER

=afrank

IP_

PW

P:d

ms6

16

72

\MA

RIO

N_

E_

ST

D1

_S

HE

ET

1.D

GN

SHEET OF

MATERIALS DETAILS FOR TYPE A SIGN SUPPORTS

MD645E-MRB-01

U CHANNEL SIGN SUPPORTS

NUCOR STEEL, MARION INC.

41

4

6

POSTS SHALL BE PRODUCED FROM HIGH STRENGTH BILLET STEEL, GRADE 80-SP. CHEMICAL

PROPERTIES OF THE STEEL SHALL CONFORM TO ASTM A-1 AND PHYSICAL PROPERTIES SHALL

CONFORM TO ASTM A-499 (SEE TABLE 1 ).

POSTS SHALL BE HOT-DIP GALVANIZED AFTER FABRICATION IN ACCORDANCE WITH ASTM A-123.

SPLICE HARDWARE SHALL BE AS SUPPLIED OR RECOMMENDED BY THE MANUFACURER, EITHER

ZINC-PLATED PER ASTM B-633 (MINIMUM 0.315 MIL COATING THICKNESS) OR CADMIUM PLATED

ACCORDING TO ASTM B-766 (CLASS B).

THE GEOTECHNICAL ENGINEERING BUREAU AND THE STRUCTURES DIVISION SHOULD BE CONTACTED

WHEN A POST IS TO BE PLACED IN A PLASTIC (SOFT CLAY OR ORGANIC) DEPOSIT, OR WHEN THE

GROUNDWATER ELEVATION IS WITHIN THE MINIMUM EMBEDMENT.

AN S-1 SOIL CONDITION SHOULD BE ASSUMED. S-1 INCLUDES SANDS, GRAVELS AND SILTS

(AND THEIR MIXTURES) WHICH EXHIBIT PENETRATION VALUES OF 9 OR MORE BLOWS PER FOOT

USING A STANDARD 300 LB. DROP HAMMER AND AN 18 INCH FALL. SHOULDER MATERIALS ARE

INCLUDED IN THIS CATEGORY.

7 FT. MAX

STANDARD CAPACITY

Group #37829 IFB #23055 - Attachment 08: Nucor Steel, Marion Inc.

0. 0

1 . 0

2. 0

3. 0

4. 0

5. 0

6. 0

7. 0

8. 0

9. 0

1 0. 0

1 1 . 0

1 2. 0

1 3. 0

1 4. 0

1 5. 0

1 6. 0

1 7. 0

1 8. 0

1 9. 0

20. 0

5 6 7 8 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6

0. 0

1 . 0

2. 0

3. 0

4. 0

5. 0

6. 0

7. 0

8. 0

9. 0

1 0. 0

1 1 . 0

1 2. 0

1 3. 0

1 4. 0

1 5. 0

1 6. 0

1 7. 0

1 8. 0

1 9. 0

20. 0

5 6 7 8 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6

SINGLE POST

SIGN PANEL CENTROID HEIGHT (FT) SIGN PANEL CENTROID HEIGHT (FT)

70 MPH WIND SPEED60 MPH WIND SPEED

2S

IGN

PA

NE

L A

RE

A (

FT

)

CAUTION : ALLOWABLE SIGN PANEL AREAS ARE CALCULATED ASSUMING SITE ELEVATIONS CLOSE TO THE SURROUNDING TERRAIN.

FOR ELEVATED SITE CONDITIONS (E.G. OVERPASSES, HIGH CONTOUR AREAS) WHERE THE INFLUENCE OF THE GROUND ON THE WIND IS

REDUCED, ALLOWABLE SIGN PANEL AREAS MUST BE REDUCED (AS MUCH AS 40%) ACCORDING TO THE AASHTO "STANDARD SPECIFICATIONS

FOR STRUCTURAL SUPPORTS FOR HIGHWAY SIGNS, LUMINAIRES AND TRAFFIC SIGNALS", UNDER THE SECTION "LOADS".

USE AN INCREASED WIND PRESSURE FOR SIGN PANEL CENTROID HEIGHTS 29.0 FT OR MORE ABOVE THE SURROUNDING TERRAIN, AS FOLLOWS:

ZONE A (REGIONS 1,2,6,8 AND 9): 20.4 PSF

ZONE B (REGIONS 3,4,5,7,10 AND 11): 27.6 PSF

STATE OF NEW YORK

DEPARTMENT OF TRANSPORTATION

REVISION: ,

DIMENSIONS ARE IN INCHES UNLESS OTHERWISE NOTED

05

-MA

Y-2

00

6 1

4:2

1

FIL

E N

AM

E =

DA

TE

/TIM

E =

US

ER

=afrank

IP_P

WP

:dm

s61672\M

AR

ION

_E

_S

TD

1_S

HE

ET

2.D

GN

SHEET OF

MATERIALS DETAILS FOR TYPE A SIGN SUPPORTS

MD645E-MRB-02

STANDARD CAPACITY

U CHANNEL SIGN SUPPORTS

NUCOR STEEL, MARION INC.

42

4.00 lb/ft POST

3.00 lb/ft POST

2.50 lb/ft POST

2.00 lb/ft POST

2.75 lb/ft POST

ISSUED UNDER

EFFECTIVE:

05/02/2006

THESE DETAILS ARE SKETCH DRAWINGS AND ARE NOT TO SCALE

EB 06-021

Group #37829 IFB #23055 - Attachment 08: Nucor Steel, Marion Inc.

0 . 0

1 0 . 0

20 . 0

30 . 0

40 . 0

50 . 0

60 . 0

70 . 0

80 . 0

90 . 0

1 00 . 0

5 6 7 8 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6

0 . 0

1 0 . 0

20 . 0

30 . 0

40 . 0

50 . 0

60 . 0

70 . 0

80 . 0

90 . 0

1 00 . 0

5 6 7 8 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6

SIGN PANEL CENTROID HEIGHT (FT) SIGN PANEL CENTROID HEIGHT (FT)

2S

IGN

PA

NE

L A

RE

A (

FT

)

DOUBLE POST TRIPLE POST

60 MPH WIND ZONE

CAUTION : ALLOWABLE SIGN PANEL AREAS ARE CALCULATED ASSUMING SITE ELEVATIONS CLOSE TO THE SURROUNDING TERRAIN.

FOR ELEVATED SITE CONDITIONS (E.G. OVERPASSES, HIGH CONTOUR AREAS) WHERE THE INFLUENCE OF THE GROUND ON THE WIND IS

REDUCED, ALLOWABLE SIGN PANEL AREAS MUST BE REDUCED (AS MUCH AS 40%) ACCORDING TO THE AASHTO "STANDARD SPECIFICATIONS

FOR STRUCTURAL SUPPORTS FOR HIGHWAY SIGNS, LUMINAIRES AND TRAFFIC SIGNALS", UNDER THE SECTION "LOADS".

USE AN INCREASED WIND PRESSURE FOR SIGN PANEL CENTROID HEIGHTS 29.0 FT OR MORE ABOVE THE SURROUNDING TERRAIN, AS FOLLOWS:

ZONE A (REGIONS 1,2,6,8 AND 9): 20.4 PSF

ZONE B (REGIONS 3,4,5,7,10 AND 11): 27.6 PSF

STATE OF NEW YORK

DEPARTMENT OF TRANSPORTATION

REVISION: ,

DIMENSIONS ARE IN INCHES UNLESS OTHERWISE NOTED

05

-MA

Y-2

00

6 1

4:2

1

FIL

E N

AM

E =

DA

TE

/TIM

E =

US

ER

=afrank

IP_

PW

P:d

ms6

16

72

\MA

RIO

N_

E_

ST

D1

_S

HE

ET

3.D

GN

SHEET OF

MATERIALS DETAILS FOR TYPE A SIGN SUPPORTS

MD645E-MRB-03

STANDARD CAPACITY

U CHANNEL SIGN SUPPORTS

NUCOR STEEL, MARION INC.

43

4.00 lb/ft POST

3.00 lb/ft POST

2.50 lb/ft POST

2.00 lb/ft POST

2.75 lb/ft POST

ISSUED UNDER

EFFECTIVE:

05/02/2006

THESE DETAILS ARE SKETCH DRAWINGS AND ARE NOT TO SCALE

EB 06-021

Group #37829 IFB #23055 - Attachment 08: Nucor Steel, Marion Inc.

0. 0

1 0. 0

20. 0

30. 0

40. 0

50. 0

60. 0

70. 0

5 6 7 8 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6

0. 0

1 0. 0

20. 0

30. 0

40. 0

50. 0

60. 0

70. 0

5 6 7 8 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6

SIGN PANEL CENTROID HEIGHT (FT) SIGN PANEL CENTROID HEIGHT (FT)

4.00 LB/FT POST

3.00 LB/FT POST

2.75 LB/FT POST

2.50 LB/FT POST

2.00 LB/FT POST

2S

IGN

PA

NE

L A

RE

A (

FT

)

DOUBLE POST TRIPLE POST

70 MPH WIND SPEED

STATE OF NEW YORK

DEPARTMENT OF TRANSPORTATION

REVISION: ,

DIMENSIONS ARE IN INCHES UNLESS OTHERWISE NOTED

05

-MA

Y-2

00

6 1

4:2

1

FIL

E N

AM

E =

DA

TE

/TIM

E =

US

ER

=afrank

IP_P

WP

:dm

s61672\M

AR

ION

_E

_S

TD

1_S

HE

ET

4.D

GN

SHEET OF

MATERIALS DETAILS FOR TYPE A SIGN SUPPORTS

MD645E-MRB-04

STANDARD CAPACITY

U CHANNEL SIGN SUPPORTS

NUCOR STEEL, MARION INC.

44

CAUTION : ALLOWABLE SIGN PANEL AREAS ARE CALCULATED ASSUMING SITE ELEVATIONS CLOSE TO THE SURROUNDING TERRAIN.

FOR ELEVATED SITE CONDITIONS (E.G. OVERPASSES, HIGH CONTOUR AREAS) WHERE THE INFLUENCE OF THE GROUND ON THE WIND IS

REDUCED, ALLOWABLE SIGN PANEL AREAS MUST BE REDUCED (AS MUCH AS 40%) ACCORDING TO THE AASHTO "STANDARD SPECIFICATIONS

FOR STRUCTURAL SUPPORTS FOR HIGHWAY SIGNS, LUMINAIRES AND TRAFFIC SIGNALS", UNDER THE SECTION "LOADS".

USE AN INCREASED WIND PRESSURE FOR SIGN PANEL CENTROID HEIGHTS 29.0 FT OR MORE ABOVE THE SURROUNDING TERRAIN, AS FOLLOWS:

ZONE A (REGIONS 1,2,6,8 AND 9): 20.4 PSF

ZONE B (REGIONS 3,4,5,7,10 AND 11): 27.6 PSF

ISSUED UNDER

EFFECTIVE:

05/02/2006

THESE DETAILS ARE SKETCH DRAWINGS AND ARE NOT TO SCALE

EB 06-021

Group #37829 IFB #23055 - Attachment 08: Nucor Steel, Marion Inc.

+

1----c --I

1 ' TABLE I : FLAT-BACK POST PROPERTIES & DIMENSIONS

POST AREA I s MOMENT• SIZE On'J Cln'J Cln'J A B c D E

-A

D E�

1 l ___) FLAT-BACK \. T1 B I

I I

2.00 b/ft 0.55 0.16 0.19 1.503 3.125 1.250 0.114 0.116 931 ft-lbs

2.50 b/ft 0.69 0.21 Q.26 1.549 3.125 1.250 0.160 0.130 1214 ft-bs

3.00 b/ft 0.86 0.34 0.36 1.750 3.500 1.625 0.160 0.150 1764 fHbs

4.00 lb/ft 1.15 D.45 0.47 I.BIO 3.500 1.625 0.220 0.162 2303 ft-bs

• REDUCE MOMENT CAPACITY BY 25X TO ACCOUNT FOR TORSION EFFECTS IN OPEN CROSS-SECTION SINGLE POST INSTALLATIONS.

1----c --I

1 TABLE 2 INDENTED-BACK POST PROPERTIES & DIMENSIONS :

POST AREA I s MOMENT• SIZE On'J Cln'J lln'J A B c D E - A

D E�

L_l l ___) INDENTED-BACK

T1 B I I

2.00 b/ft 0.60 0.19 D.24 [.562 3.088 [.214 0.113 0.112 931 ft�bs

2.50 b/ft 0.74 0.25 0.30 1.607 3.088 1.214 0.155 0.121 1274 ft-bs

3.00 b/ft 0.90 0.38 0.45 1.825 3.458 1.577 0.157 0.140 1764 fHbs

4.00 lb/ft 1.16 0.53 0.59 1.895 3.551 1.577 0.225 0.154 2303 ft-bs

• REDUCE MOMENT CAPACITY BY 25X TO ACCOUNT FOR TORSION EFFECTS IN OPEN CROSS-SECTION SINGLE POST INSTALLATIONS.

TABLE 3: MAXIMUM NUMBER OF POSTS WITHIN 7 FT.SWATH

SOIL SUPES SOIL DESCRIPTION

S - I S - 2

1-��EMBEDMENT SOIL NON-PLASTIC NON-PLASTIC

TYPE SLOPE (MED TO VERY COMPACT! (LOOSE TO VERY LOOSEJ

• MAX NO. MIN. SOIL It

MAX NO. MIN

I I

..., ... ,2 3 4

I STEEP I ..... ,.HORIZONTAL

-

--

--

5

I FLAT EZE-ERECT

BASE-BOLTED

4" MAX 6,,

__l_

y�[ EMBEDMENT DEPTH, D

38' MINIMUM VARIES l!TH SLOPE,

SEE Wl.L3

_L:>------ 7 FT. MAX ---.i:

SOIL PLATE DETAIL

OF POSTS FLAT

MODERATE STEEP FLAT

MODERATE STEEP

-

HA\<

}-BOLT HOLES AT I' FROM EDGE

14 x 14 x 1/-1" THICK STEEL SOIL PLATE

2 2 2 3 3 3

EMBEDMENT 38 54 60 38 54 60

NO NO NO NO NO NO

OF POSTS EMBEDMENT SOIL It I 38 YES l 54 YES l 60 YES 3 60 YES 3 60 YES 3 60 YES

= -CENTROID OF

c SIGN ASSEMBLY :::::\

1 :--SIGN, POST

-

MOUNTING I

HEIGHT I

SIGN --LI iRi�RU�}�·i�� ��TR�}oi·�� :p

� I

D

5

S

:

F

:

C

GROUND

SURFr

�1 1

5 TO 6 ..

.... T 1 OVERLAP -f- j OVERLAP

� 38' MINIMUM ,r,ri(\\ j BASE i] EMBEDMENT []-- BASE POST !SEE Wl.L'I POST

j

STEEP SLOPES GENTLE SLOPES

EMBEDMENT DETAILS

POSTS SHALL BE PRODUCED FROM STANDARD "T' RAIL STEEL WEIGHING 91 LB/YD OR MORE ACCORDING TO ASTM A-499, GRADE 60, HAVING A 70 KS! M!N!IUI YIELD !SEE TABLES 1 l 21. POST WEIGHT IS FROM 2.00 TO 4.00 LBS/FT BEFORE PltlCH!NG. SIGN POSTS SHALL BE PUNCHED THEIR FULL LENGTH WITH 3/8" - HOLES ON I' CENTERS. BASE POSTS SHALL BE PUNCHED l!TH A MINIMUM OF TIENTY-FOLR 3/8" - HOLES ON I' CENTERS !TO ACCOMODATE OPTIONAL SOIL PLATE> l!TH THE FIRST HOLE I' FROM THE TOP. THE FIRST AND THE FIFTH HOLES SHALL BE 3/8" X 0.500" SLOTS TO FACILITATE CORRECT FIELD ALIGNMENT. BASE POSTS SHALL BE DRIVEN TO 38' MINIMUM EMBEDMENT ISEE TAB! E 3� A MAXIMUM OF 4' MAY PROTRUDE ABOVE THE SURROUNDING GROLNJ SURF ACE. POSTS SHALL BE HOT-DIP GALVANIZED AFTER FABRICATION IN ACCORDANCE WITH ASTM A-123. SPLICE HARDI ARE SHALL BE AS SUPPLIED OR RECOMMENDED BY THE MANIF ACURER, CADMIUM PLATED ACCORDING TO ASTM A-165, TYPE OS, EXCEPT USING CLEAR CHROMATE. ALL GALVANIZING AND GALVAN!ZlNG REPAIRS SHALL BE DONE IN ACCORDANCE WITH §719-01,TYPE l!L AN S-1 SOIL COND!TlON SHOULD BE ASSUMED. S-1 INCLUDES SANDS, GRAVELS AND SILTS CAND THEIR MIXTURES! IH!CH EXHIBIT PENETRATION VALUES OF 9 OR MORE BLOIS PER FOOT USING A STANDARD 300 LB. DROP HAMMER AND AN 18 INCH FALL. SHOULDER MATERIALS ARE INCLUDED IN THIS CATEGORY. S-2 INCLUDES UNIFORM SANDS IH!CH EXHIBIT PENETRATION VALUES OF LESS THAN 9 BLOIS PERFOOT USING A 300 LB. DROP HAMMER. BEACH SANDS ARE INCLUDED IN THIS CATEGORY.THE GEOTECHN!CAL ENGINEERING BUREAU AND THE STRUCTURES DIVISION SHOULD BE CONTACTED IHEN A POST IS TO BE PLACED IN A PLASTIC !SOFT CLAY OR ORGANIC! DEPOSIT, OR IHEN THE GROUMDWATER ELEVATION IS WITHIN THE MINIMUM EMBEDMENT.

THESE DETAILS ARE SKETCH DRAWINGS AND ARE NOT TO SCALE DIMENSIONS ARE IN INCHES UNLESS OTHERWISE NOTED

STATE OF NEW YORK

DEPARTMENT OF TRANSPORTATION

MATERIALS DETAILS FOR TYPE A SIGN SUPPORTS

FRANKLIN INDUSTRIES COMPANY U CHANNEL SIGN SIJ'PORTS

STANDARD CAPACITY

SHEET l OF 5

ISSUED UNDER EB 06-021 EFFECTIVE: 05/02/2006 MD645E-FEZ-01 REVISION1

Group #37829 IFB #23055 - Attachment 08: Franklin Industries Co.

IF LESS THAN 3/4"

USE 2ND & 6TH HOLES

INSTEAD OF 1ST & 5TH

BASE

POST

FLAT-BACK (BASE-BOLTED SPLICE)

LOCKWASHER AND

INTEGRAL FLANGE NUT

4

IF LESS THAN 3/4"

USE 2ND & 6TH HOLES

INSTEAD OF 1ST & 5TH

BASE

POST

BURR THREADS

OR BEND BOLT

17-1/8" LONG X 1" WIDE

3/8" THICK POST RETAINER

SPACER STRAP

4

5/16 - 18 UNC x 2.0"

GRADE 8 INTEGRAL

FLANGE HEX HEAD

BOLTS & FLAT WASHERS

TORQUE LOWER TWO BOLTS

TO 20 FT-LBS.

IF LESS THAN 3/4"

USE 2ND & 6TH HOLES

INSTEAD OF 1ST & 5TH

FLAT-BACK (EZE-ERECT SPLICE)

INDENTED-BACK (BASE-BOLTED SPLICE)

5/16 -18 UNC x 2.25"

GRADE 9 HEX HEAD

BOLTS & FLAT WASHERS

TORQUE 20 FT-LBS.

SIGN POST

IF LESS THAN 3/4"

USE 2ND & 6TH HOLES

INSTEAD OF 1ST & 5TH5/16 -18 UNC x 2.25"

GRADE 9 HEX HEAD

BOLTS & FLAT WASHERS

TORQUE 20 FT-LBS.

SIGN POST

3/4 x 3/4 x 3/4"

UNTHREADED ZINC

COATED SPACER

IF LESS THAN 3/4"

USE 2ND & 6TH HOLES

INSTEAD OF 1ST & 5TH

7/16" I.D. x 1" O.D. x 5/8" THICK

UNTHREADED ZINC-PLATED SPACER

FIRST HOLE

IF LESS THAN 3/4"

USE 2ND & 6TH HOLES

INSTEAD OF 1ST & 5TH

SIGN

POST

BASE

POST

4

STATE OF NEW YORK

DEPARTMENT OF TRANSPORTATION

REVISION: ,

DIMENSIONS ARE IN INCHES UNLESS OTHERWISE NOTED

05

-MA

Y-2

00

6 1

4:1

1

FIL

E N

AM

E =

DA

TE

/TIM

E =

US

ER

=afrank

IP_

PW

P:d

ms6

16

72

\FR

A_

E_

ST

D1

_S

HE

ET

2.D

GN

SHEET OF

MATERIALS DETAILS FOR TYPE A SIGN SUPPORTS

2

5

MD645E-FEZ-02

U CHANNEL SIGN SUPPORTS

FRANKLIN INDUSTRIES COMPANY

STANDARD CAPACITY

HEX HEAD BOLT,NUT AND HEAVY

DUTY LOCKWASHER (OR AN

INTEGRAL FLANGED LOCKNUT)

TORQUE TO 20 FT-LBS.

HEX-HEAD BOLT NUT AND HEAVY

DUTY LOCKWASHER (OR

INTEGRAL FLANGED LOCKNUT)

TORQUE TO 20 FT-LBS.

ISSUED UNDER

EFFECTIVE:

05/02/2006

THESE DETAILS ARE SKETCH DRAWINGS AND ARE NOT TO SCALE

EB 06-021

Group #37829 IFB #23055 - Attachment 08: Franklin Industries Co.

SINGLE POST

SIGN PANEL CENTROID HEIGHT (FT) SIGN PANEL CENTROID HEIGHT (FT)

70 MPH WIND SPEED60 MPH WIND SPEED

40.0

6151413121110198765

3 0 .0

2 0 0.

00 .1

0 .0

50.0

2S

IGN

PA

NE

L A

RE

A (

FT

)

5 6 7 8

10.0

0.0

20.0

30.0

40.0

50.0

9 10 11 12 13 14 15 16

CAUTION : ALLOWABLE SIGN PANEL AREAS ARE CALCULATED ASSUMING SITE ELEVATIONS CLOSE TO THE SURROUNDING TERRAIN.

FOR ELEVATED SITE CONDITIONS (E.G. OVERPASSES, HIGH CONTOUR AREAS) WHERE THE INFLUENCE OF THE GROUND ON THE WIND IS

REDUCED, ALLOWABLE SIGN PANEL AREAS MUST BE REDUCED (AS MUCH AS 40%) ACCORDING TO THE AASHTO "STANDARD SPECIFICATIONS

FOR STRUCTURAL SUPPORTS FOR HIGHWAY SIGNS, LUMINAIRES AND TRAFFIC SIGNALS", UNDER THE SECTION "LOADS".

USE AN INCREASED WIND PRESSURE FOR SIGN PANEL CENTROID HEIGHTS 29.0 FT OR MORE ABOVE THE SURROUNDING TERRAIN, AS FOLLOWS:

ZONE A (REGIONS 1,2,6,8 AND 9): 20.4 PSF

ZONE B (REGIONS 3,4,5,7,10 AND 11): 27.6 PSF

4.00 lb/ft POST

3.00 lb/ft POST

2.50 lb/ft POST

2.00 lb/ft POST

STATE OF NEW YORK

DEPARTMENT OF TRANSPORTATION

REVISION: ,

DIMENSIONS ARE IN INCHES UNLESS OTHERWISE NOTED

05

-MA

Y-2

00

6 1

4:1

1

FIL

E N

AM

E =

DA

TE

/TIM

E =

US

ER

=afrank

IP_P

WP

:dm

s61672\F

RA

_E

_S

TD

1_S

HE

ET

3.D

GN

SHEET OF

MATERIALS DETAILS FOR TYPE A SIGN SUPPORTS

FRANKLIN INDUSTRIES COMPANY

MD645E-FEZ-03

STANDARD CAPACITY

U CHANNEL SIGN SUPPORTS

53

ISSUED UNDER

EFFECTIVE:

05/02/2006

THESE DETAILS ARE SKETCH DRAWINGS AND ARE NOT TO SCALE

EB 06-021

Group #37829 IFB #23055 - Attachment 08: Franklin Industries Co.

61514131211101987655 6 7 8 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6

SIGN PANEL CENTROID HEIGHT (FT) SIGN PANEL CENTROID HEIGHT (FT)

2S

IGN

PA

NE

L A

RE

A (

FT

)

100.0

90.0

80.0

70.0

60.0

50.0

40.0

30.0

20.0

10.0

0.0

100.0

90.0

80.0

70.0

60.0

50.0

40.0

30.0

20.0

10.0

0.0

DOUBLE POST

60 MPH WIND SPEED

TRIPLE POST

CAUTION : ALLOWABLE SIGN PANEL AREAS ARE CALCULATED ASSUMING SITE ELEVATIONS CLOSE TO THE SURROUNDING TERRAIN.

FOR ELEVATED SITE CONDITIONS (E.G. OVERPASSES, HIGH CONTOUR AREAS) WHERE THE INFLUENCE OF THE GROUND ON THE WIND IS

REDUCED, ALLOWABLE SIGN PANEL AREAS MUST BE REDUCED (AS MUCH AS 40%) ACCORDING TO THE AASHTO "STANDARD SPECIFICATIONS

FOR STRUCTURAL SUPPORTS FOR HIGHWAY SIGNS, LUMINAIRES AND TRAFFIC SIGNALS", UNDER THE SECTION "LOADS".

USE AN INCREASED WIND PRESSURE FOR SIGN PANEL CENTROID HEIGHTS 29.0 FT OR MORE ABOVE THE SURROUNDING TERRAIN, AS FOLLOWS:

ZONE A (REGIONS 1,2,6,8 AND 9): 20.4 PSF

ZONE B (REGIONS 3,4,5,7,10 AND 11): 27.6 PSF

4.00 lb/ft POST

3.00 lb/ft POST

2.50 lb/ft POST

2.00 lb/ft POST

STATE OF NEW YORK

DEPARTMENT OF TRANSPORTATION

REVISION: ,

DIMENSIONS ARE IN INCHES UNLESS OTHERWISE NOTED

05

-MA

Y-2

00

6 1

4:1

1

FIL

E N

AM

E =

DA

TE

/TIM

E =

US

ER

=afrank

IP_

PW

P:d

ms6

16

72

\FR

A_

E_

ST

D1

_S

HE

ET

4.D

GN

SHEET OF

MATERIALS DETAILS FOR TYPE A SIGN SUPPORTS

FRANKLIN INDUSTRIES COMPANY

MD645E-FEZ-04

STANDARD CAPACITY

U CHANNEL SIGN SUPPORTS

54

ISSUED UNDER

EFFECTIVE:

05/02/2006

THESE DETAILS ARE SKETCH DRAWINGS AND ARE NOT TO SCALE

EB 06-021

Group #37829 IFB #23055 - Attachment 08: Franklin Industries Co.

5 6 7 8 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6 6151413121110198765

DOUBLE POST TRIPLE POST

70 MPH WIND SPEED

2S

IGN

PA

NE

L A

RE

A (

FT

)

100.0

90.0

80.0

70.0

60.0

50.0

40.0

30.0

20.0

10.0

0.0

90.0

80.0

70.0

60.0

50.0

40.0

30.0

20.0

10.0

0.0

SIGN PANEL CENTROID HEIGHT (FT) SIGN PANEL CENTROID HEIGHT (FT)

100.0

4.00 lb/ft POST

3.00 lb/ft POST

2.50 lb/ft POST

2.00 lb/ft POST

STATE OF NEW YORK

DEPARTMENT OF TRANSPORTATION

REVISION: ,

DIMENSIONS ARE IN INCHES UNLESS OTHERWISE NOTED

05

-MA

Y-2

00

6 1

4:1

1

FIL

E N

AM

E =

DA

TE

/TIM

E =

US

ER

=afrank

IP_

PW

P:d

ms6

16

72

\FR

A_

E_

ST

D1

_S

HE

ET

5.D

GN

SHEET OF

MATERIALS DETAILS FOR TYPE A SIGN SUPPORTS

FRANKLIN INDUSTRIES COMPANY

MD645E-FEZ-05

STANDARD CAPACITY

U CHANNEL SIGN SUPPORTS

55

CAUTION : ALLOWABLE SIGN PANEL AREAS ARE CALCULATED ASSUMING SITE ELEVATIONS CLOSE TO THE SURROUNDING TERRAIN.

FOR ELEVATED SITE CONDITIONS (E.G. OVERPASSES, HIGH CONTOUR AREAS) WHERE THE INFLUENCE OF THE GROUND ON THE WIND IS

REDUCED, ALLOWABLE SIGN PANEL AREAS MUST BE REDUCED (AS MUCH AS 40%) ACCORDING TO THE AASHTO "STANDARD SPECIFICATIONS

FOR STRUCTURAL SUPPORTS FOR HIGHWAY SIGNS, LUMINAIRES AND TRAFFIC SIGNALS", UNDER THE SECTION "LOADS".

USE AN INCREASED WIND PRESSURE FOR SIGN PANEL CENTROID HEIGHTS 29.0 FT OR MORE ABOVE THE SURROUNDING TERRAIN, AS FOLLOWS:

ZONE A (REGIONS 1,2,6,8 AND 9): 20.4 PSF

ZONE B (REGIONS 3,4,5,7,10 AND 11): 27.6 PSF

ISSUED UNDER

EFFECTIVE:

05/02/2006

THESE DETAILS ARE SKETCH DRAWINGS AND ARE NOT TO SCALE

EB 06-021

Group #37829 IFB #23055 - Attachment 08: Franklin Industries Co.