groundwater recharge from mains leakage
description
Transcript of groundwater recharge from mains leakage
![Page 1: groundwater recharge from mains leakage](https://reader035.fdocuments.in/reader035/viewer/2022062322/56814886550346895db59826/html5/thumbnails/1.jpg)
groundwater recharge from mains leakage
Beatriz Garcia-FrescaNovember 2002
CE 394K.3 GIS in Water Resources
![Page 2: groundwater recharge from mains leakage](https://reader035.fdocuments.in/reader035/viewer/2022062322/56814886550346895db59826/html5/thumbnails/2.jpg)
datasets:GEOLOGY
![Page 3: groundwater recharge from mains leakage](https://reader035.fdocuments.in/reader035/viewer/2022062322/56814886550346895db59826/html5/thumbnails/3.jpg)
geology + city footprint
![Page 4: groundwater recharge from mains leakage](https://reader035.fdocuments.in/reader035/viewer/2022062322/56814886550346895db59826/html5/thumbnails/4.jpg)
datasets:WATERMAINS
source:City of Austin GIS datasets
![Page 5: groundwater recharge from mains leakage](https://reader035.fdocuments.in/reader035/viewer/2022062322/56814886550346895db59826/html5/thumbnails/5.jpg)
data processing
• reprojecting Texas Central State Plane (US ft)
• spatial analysis reclassification of geology
according to relative permeability
• calculations: CoA water usage leakage
• geoprocessing: isolating pipes by aquifer group
![Page 6: groundwater recharge from mains leakage](https://reader035.fdocuments.in/reader035/viewer/2022062322/56814886550346895db59826/html5/thumbnails/6.jpg)
relative permeabilities
![Page 7: groundwater recharge from mains leakage](https://reader035.fdocuments.in/reader035/viewer/2022062322/56814886550346895db59826/html5/thumbnails/7.jpg)
relative permeabilities
![Page 8: groundwater recharge from mains leakage](https://reader035.fdocuments.in/reader035/viewer/2022062322/56814886550346895db59826/html5/thumbnails/8.jpg)
calculations
Pumpage pumpage real loss daily average
Year (millions of gallons) millions m3 millions m3 m3/d
1993 39,824 151 10.57 413514.96
1994 39,806 151 10.56 413328.05
1995 39,542 150 10.49 410586.79
1996 45,835 174 12.16 475930.55
1997 42,812 162 11.36 444541.04
1998 46,438 176 12.32 482191.84
1999 46,422 176 12.32 482025.70
2000 52,193 198 13.85 541949.23
2001 50,140 190 13.30 520631.78
↑ ↑
City of Austin - Water and Wastewater Utility
![Page 9: groundwater recharge from mains leakage](https://reader035.fdocuments.in/reader035/viewer/2022062322/56814886550346895db59826/html5/thumbnails/9.jpg)
calculations
• attributes: diameter & length
• calculations: – V each pipe– total V pipes– daily V of water per pipe– daily leakage (~7%)– add leakage of all pipes
![Page 10: groundwater recharge from mains leakage](https://reader035.fdocuments.in/reader035/viewer/2022062322/56814886550346895db59826/html5/thumbnails/10.jpg)
summary and resultsaverage pumpage CoA 520631.78 m3/d CoA Water &
Wastewater Utility total V of pipes 672465.55 m3 from GIS project coeff. 0.774
area of Austin 271.8 sqmi City of Austin – Austin Facts703.962 Km2
annual precipitation 840 mm NOOA
total mains loss 12 % Austin American Statesman, 1998
real loss (leakage) 7 % Thornton, 200236434.2 m3/d results from GIS
project13.3 million m3/a18.89 mm/a4.80 in/a
![Page 11: groundwater recharge from mains leakage](https://reader035.fdocuments.in/reader035/viewer/2022062322/56814886550346895db59826/html5/thumbnails/11.jpg)
![Page 12: groundwater recharge from mains leakage](https://reader035.fdocuments.in/reader035/viewer/2022062322/56814886550346895db59826/html5/thumbnails/12.jpg)
![Page 13: groundwater recharge from mains leakage](https://reader035.fdocuments.in/reader035/viewer/2022062322/56814886550346895db59826/html5/thumbnails/13.jpg)
![Page 14: groundwater recharge from mains leakage](https://reader035.fdocuments.in/reader035/viewer/2022062322/56814886550346895db59826/html5/thumbnails/14.jpg)
datasets:WASTEWATE
RMAINS
source:City of Austin GIS datasets
Work in progress
![Page 15: groundwater recharge from mains leakage](https://reader035.fdocuments.in/reader035/viewer/2022062322/56814886550346895db59826/html5/thumbnails/15.jpg)
a fundigression
![Page 16: groundwater recharge from mains leakage](https://reader035.fdocuments.in/reader035/viewer/2022062322/56814886550346895db59826/html5/thumbnails/16.jpg)
![Page 17: groundwater recharge from mains leakage](https://reader035.fdocuments.in/reader035/viewer/2022062322/56814886550346895db59826/html5/thumbnails/17.jpg)
![Page 18: groundwater recharge from mains leakage](https://reader035.fdocuments.in/reader035/viewer/2022062322/56814886550346895db59826/html5/thumbnails/18.jpg)
conclusions
• the urban induced recharge in Austin is significant
• utility lines can be analyzed using ArcHydro tools
• ArcGIS presents more operational problems than ArcView
![Page 19: groundwater recharge from mains leakage](https://reader035.fdocuments.in/reader035/viewer/2022062322/56814886550346895db59826/html5/thumbnails/19.jpg)
future work
• add recharge from wastewater mains– what are the qualitative implications?
• refine calculations:– include infiltration coeffs. of soils?