Flare and Vent Gas _______ Mass Balance _______ Gas Waste Streams Non-Invasive Ultrasonic Flare Gas Flow Mesurement Accurate - Reliable - Versatile FLEXIM when measuring matters

Transcript of GR N52 Non-Invasive Ultrasonic - Flow Measurement · 2018-05-03 · The non-invasive ultrasonic...

Page 1: GR N52 Non-Invasive Ultrasonic - Flow Measurement · 2018-05-03 · The non-invasive ultrasonic transit-time flow measurement technology employed by FLUXUS ®, is the ideal metering

Flare and Vent Gas_______

Mass Balance_______

Gas Waste Streams

Non-Invasive Ultrasonic Flare Gas Flow Mesurement

Accurate - Reliable - Versatile

BUFG

V2-1

US

2018

/04

Sub

ject

to c

hang

e w

ithou

t not

ifica

tion

FLEXIM when measuring matters

FLUXUS® Flare Gas Meter

Non-invasive Ultrasonic Transit Time Measurement Principle

Quantities of measurement:

Standard and actual volume flow, mass flow, totalized standard volume flow, totalized mass flow, flow velocity

Flow Velocity: 1 ft/s to 400 ft/s

Accuracy: ± 1 ... 3%, ± 0.03 ft/s (depending on application)± 0.5% ± 0.03 ft/s (field calibrated)

Repeatability: 0,15%

Pipe Sizes: 2” to 12”

Pipe Material: Polyproplyene resin (Proline)Clamp-on System: Stainless Steel

Temperature range: up to 75 °F at 150 PSI, up to 200 °F at 10 PSI

Pressure range: up to 150 PSI

Certification: cFM Class I Div. 2

Input types: Maximum of 4, Available are: temperature (Pt 100, Pt 1000), current, voltage

Output types: A variety of combinations are available from the following: current (0/4 mA to 20 m/A), voltage, frequency, pulse, alarm

Communication: HART or Foundation Fieldbus or Modbus RTU or RS485 or BACnet MS/TP

FLEXIM AMERICAS CorporationHeadquarter250-V Executive DriveEdgewood, NY 11717Phone: (631) 492-2300

FLEXIM has offi ces located throughout North America.

Please have a look for your local representative at:

www.flexim.comor call us at:

1-888-852-PIPE

www.flexim.com

Flow Direction

Transducer Type:GRx1N52(Flow Sensors)

P/N MOU-PLK-DS-SBKX(PermaLok - Mounting Track with Solid Straps)

P/N 770413-1(1x Pt1000 Temperature Sensor)[4-Wire RTD, integral cable 20']

Shown transducer: GRG1N52; mounted in one (1) sound path

P/N US-MOU.SBK-x(Solid Banding Strap){x = various sizes based on pipe OD}

P/N US-G704.MCI with US-7407.316SE(G705 Gas Flow Meter - Transmitter)

Min SCNR ≥ 30Min SNR ≥ 20

Nomial Pipe Size

OD (inch)

WT (inch)

Length (inch)

Transducers

3 3.543 0.323 244 4.331 0.394 246 6.299 0.575 368 7.874 0.717 36

10 9.843 0.898 3612 12.402 1.130 36

GRH1N52

GRG1N52

SDR11 - Proline Pro 150

Pow

er In

Outp

uts

mA

Inpu

ts

Page 2: GR N52 Non-Invasive Ultrasonic - Flow Measurement · 2018-05-03 · The non-invasive ultrasonic transit-time flow measurement technology employed by FLUXUS ®, is the ideal metering

The non-invasive ultrasonic transit-time flow measurement technology employed by FLUXUS®, is the ideal metering solution for flare gas applications.As the transducers are mounted onto the outside of the pipe wall, there are no moving parts and thus no interference with the flow in any way.Further, the system is virtually maintenance-free, thus significantly reducing costs and increasing the lifetime of the meter.One of the challenges of measuring flare gas is the ability to measure extremely low flows in purging situations as well as high flow velocities during flaring events. FLUXUS® achieves an unrivalled accuracy and reliability at such variab-le conditions by emitting and recieving over 1.000 measurement signals per second and employing a standard setting digital signal processing algorithm. By use of an additional internal temperature compensation within the ultra-sonic transducer according to ANSI/ASME standards, measurement drift is competely ruled out. FLUXUS® is a superior solution in comparison to insertion meter and also inline ultrasonic meter solutions as the transducers do not intrude into the pipe itself. Installation of the measurement system can be done with minimal process in-terference by inserting the pre-fabricated spool piece.Why do this with a Polypropylene Spool? A clamp-on gas meter needs a mini-mum pressure to work on a steel pipe generally >70psi. With polypropylene it is possible to work down to ambient pressure.FLUXUS® is already the flare gas meter of choice by major Oil & Gas produ-cers - contact us for references!

FLUXUS® Ultrasonic Flare Gas Meter

Due to their harmful effect on the atmosphere, regulating agencies require flow measurement for reporting fared and wasted greenhouse gases. Waste gasses can contain moisture and residual solids. Meters that are intrusive like ultra-sonic and thermal can get fouled and become maintenance prone. The accu-racy of thermal meters can be severely affected by coatings, moisture, and the gas composition. The non-invasive nature of Flexim’s clamp-on meter makes it immune to these effects. Another very important aspect of flare metering is turndown range. The FLUXUS® ultrasonic flare gas meter is truly non-invasive and offers a virtually unlimited turndown ratio – measuring from the lowest flow rates down to 0.03ft/sec and up to 400ft/sec with an unrivalled degree of accuracy and reliability.

Flare and Waste Gas MonitoringFlare stack and feed lines are common in Oil & Gas production environments as well as at Chemical and Petrochemical plants. The flared or wasted gases can range from various natural gas compositions – including sour gas - to inorga-nic gases such as nitrogen oxides (NOx), highly reactive volatile organic com-pounds (HRVOC) and other greenhouse gases. FLUXUS® measures accurately and highly reliably over a huge turndown ratio at temperatures up to 200 °F and internal pressurization up to 150PSI.

Pressure Relief Valve Flow MeasurementInstalled downstream of relief valves feeding into the main flare header, FLUXUS® is the ideal solution to accurately and reliably indicate flow of flare gas and monitor “blowdown” events as well as potential leaks.

One for All ApplicationsApplicationsFeatures

The Superior Solution for Flare Gas Measurement

Highly accurate and reliable

Unlimited turndown ratio

Measures mass and volume flow rates,

No pressure drop, no back pressure

No maintenance – no moving parts

Certified for operations in hazardous areas

No calibration required during and after installation

Rapid installation - meter is fully preprogrammed

Flare and Vent Gas

Mass Balance

Gas Waste streams

Leak Detection

Acid Gas, Process Gases

Process optimisation

Wide velocity range and low pressure applications

One for All Applications

Page 3: GR N52 Non-Invasive Ultrasonic - Flow Measurement · 2018-05-03 · The non-invasive ultrasonic transit-time flow measurement technology employed by FLUXUS ®, is the ideal metering

Flare and Vent Gas_______

Mass Balance_______

Gas Waste Streams

Non-Invasive Ultrasonic Flare Gas Flow Mesurement

Accurate - Reliable - Versatile

BUFG

V2-1

US

2018

/04

Sub

ject

to c

hang

e w

ithou

t not

ifica

tion

FLEXIM when measuring matters

FLUXUS® Flare Gas Meter

Non-invasive Ultrasonic Transit Time Measurement Principle

Quantities of measurement:

Standard and actual volume flow, mass flow, totalized standard volume flow, totalized mass flow, flow velocity

Flow Velocity: 1 ft/s to 400 ft/s

Accuracy: ± 1 ... 3%, ± 0.03 ft/s (depending on application)± 0.5% ± 0.03 ft/s (field calibrated)

Repeatability: 0,15%

Pipe Sizes: 2” to 12”

Pipe Material: Polyproplyene resin (Proline)Clamp-on System: Stainless Steel

Temperature range: up to 75 °F at 150 PSI, up to 200 °F at 10 PSI

Pressure range: up to 150 PSI

Certification: cFM Class I Div. 2

Input types: Maximum of 4, Available are: temperature (Pt 100, Pt 1000), current, voltage

Output types: A variety of combinations are available from the following: current (0/4 mA to 20 m/A), voltage, frequency, pulse, alarm

Communication: HART or Foundation Fieldbus or Modbus RTU or RS485 or BACnet MS/TP

FLEXIM AMERICAS CorporationHeadquarter250-V Executive DriveEdgewood, NY 11717Phone: (631) 492-2300

FLEXIM has offi ces located throughout North America.

Please have a look for your local representative at:

www.flexim.comor call us at:

1-888-852-PIPE

www.flexim.com

Flow Direction

Transducer Type:GRx1N52(Flow Sensors)

P/N MOU-PLK-DS-SBKX(PermaLok - Mounting Track with Solid Straps)

P/N 770413-1(1x Pt1000 Temperature Sensor)[4-Wire RTD, integral cable 20']

Shown transducer: GRG1N52; mounted in one (1) sound path

P/N US-MOU.SBK-x(Solid Banding Strap){x = various sizes based on pipe OD}

P/N US-G704.MCI with US-7407.316SE(G705 Gas Flow Meter - Transmitter)

Min SCNR ≥ 30Min SNR ≥ 20

Nomial Pipe Size

OD (inch)

WT (inch)

Length (inch)

Transducers

3 3.543 0.323 244 4.331 0.394 246 6.299 0.575 368 7.874 0.717 36

10 9.843 0.898 3612 12.402 1.130 36

GRH1N52

GRG1N52

SDR11 - Proline Pro 150

Pow

er In

Outp

uts

mA

Inpu

ts