![Page 1: Gmp premicses](https://reader035.fdocuments.in/reader035/viewer/2022081507/589afaff1a28ab3e288b6815/html5/thumbnails/1.jpg)
A Seminar on GOOD MANUFACTURING PRACTICES PREMISES
Presented By Mr. Jagadeesh Tekkali
M.Pharmacy 1st year15AC1S0414
VIGNAN INSTITUTE OF PHARMACEUTICAL TECHNOLOGY An ISO 9001:2008, 14001:2004, OHSAS 18001:2007 Certified Institution Beside VSEZ, kapujaggarajupeta, Duvvada,VISAKHAPATNAM-530046 (Approved by A.I.C.T.E & PCI and affliated to JNTUK)
![Page 2: Gmp premicses](https://reader035.fdocuments.in/reader035/viewer/2022081507/589afaff1a28ab3e288b6815/html5/thumbnails/2.jpg)
Location Design Construction Maintenance Plant layout Sanitations Environmental control Sterile areas Contamination control
CONTENTS
![Page 3: Gmp premicses](https://reader035.fdocuments.in/reader035/viewer/2022081507/589afaff1a28ab3e288b6815/html5/thumbnails/3.jpg)
Principle
Important aspects to be kept in mind to ensure the Quality product several operations to be carried out for different dosage forms and product range:
Location Design Construction Adaptation Maintenance
![Page 4: Gmp premicses](https://reader035.fdocuments.in/reader035/viewer/2022081507/589afaff1a28ab3e288b6815/html5/thumbnails/4.jpg)
Location Geography, climate, noise and economic factors Neighbours
What do they do? What impact can they have on the business?
Pollution/effluent control Minimum risk for contamination of products and
materials
![Page 5: Gmp premicses](https://reader035.fdocuments.in/reader035/viewer/2022081507/589afaff1a28ab3e288b6815/html5/thumbnails/5.jpg)
PrinciplePremises must be
located to minimize risks of cross-contamination, e.g. not located next to a malting factory with high airborne levels of yeast
![Page 6: Gmp premicses](https://reader035.fdocuments.in/reader035/viewer/2022081507/589afaff1a28ab3e288b6815/html5/thumbnails/6.jpg)
Plant layout
The plant layout and design should aim to: Minimize risks of errors Permit effective cleaning Permit effective maintenance Avoid cross-contamination, build-up of dirt
and dust Avoid any adverse effect on the quality of
products
![Page 7: Gmp premicses](https://reader035.fdocuments.in/reader035/viewer/2022081507/589afaff1a28ab3e288b6815/html5/thumbnails/7.jpg)
Design PrinciplesKeep in mind: Material flow People flow Process flow Ensure logical flow
![Page 8: Gmp premicses](https://reader035.fdocuments.in/reader035/viewer/2022081507/589afaff1a28ab3e288b6815/html5/thumbnails/8.jpg)
Design
Suitable design and construction to facilitate good sanitation
Cleaning and disinfecting according to detailed written procedures – records maintained
Maximum protection against entry of insects, birds and animals
Procedure for rodent and pest control
![Page 9: Gmp premicses](https://reader035.fdocuments.in/reader035/viewer/2022081507/589afaff1a28ab3e288b6815/html5/thumbnails/9.jpg)
Construction
Suitable materials Electrical supply Suitable lighting (especially for visual on-line checks) Temperature and relative humidity control Appropriate and effective ventilationThese may affect products during manufacture or storage
as well as functioning of equipment
![Page 10: Gmp premicses](https://reader035.fdocuments.in/reader035/viewer/2022081507/589afaff1a28ab3e288b6815/html5/thumbnails/10.jpg)
The temperature and relative humidity should be controlled, monitored in accordance with an SOP, and the results recorded. The limits should be appropriate according to the materials stored and product processed
![Page 11: Gmp premicses](https://reader035.fdocuments.in/reader035/viewer/2022081507/589afaff1a28ab3e288b6815/html5/thumbnails/11.jpg)
Construction Dust generating operations
e.g. during sampling, weighing, mixing, packing of powders, etc.)
Measures should be taken to prevent cross-contamination
Measures to facilitate cleaning
![Page 12: Gmp premicses](https://reader035.fdocuments.in/reader035/viewer/2022081507/589afaff1a28ab3e288b6815/html5/thumbnails/12.jpg)
Maintenance
Careful maintenance done Repairs and maintenance should not present
any hazard to the quality of the products
![Page 13: Gmp premicses](https://reader035.fdocuments.in/reader035/viewer/2022081507/589afaff1a28ab3e288b6815/html5/thumbnails/13.jpg)
![Page 14: Gmp premicses](https://reader035.fdocuments.in/reader035/viewer/2022081507/589afaff1a28ab3e288b6815/html5/thumbnails/14.jpg)
some recommendations for specific areas Ancillary areas Storage areas Weighing areas Production areas Quality control areas
Control of contamination maintain few specific areas such as
![Page 15: Gmp premicses](https://reader035.fdocuments.in/reader035/viewer/2022081507/589afaff1a28ab3e288b6815/html5/thumbnails/15.jpg)
Ancillary Areas Rest and refreshment rooms separate from
manufacturing and quality control areas Changing, washing and toilet areas accessible
and appropriate numbers Maintenance workshops separated from
production - if not possible – tools in reserved areas
Animal houses well isolated – separate air handling and entrance
![Page 16: Gmp premicses](https://reader035.fdocuments.in/reader035/viewer/2022081507/589afaff1a28ab3e288b6815/html5/thumbnails/16.jpg)
![Page 17: Gmp premicses](https://reader035.fdocuments.in/reader035/viewer/2022081507/589afaff1a28ab3e288b6815/html5/thumbnails/17.jpg)
Cleaning of incoming containers
Cleaning with a cloth, or duster
Cleaning by using a vacuum cleaner
Use of air curtains and air tunnels
![Page 18: Gmp premicses](https://reader035.fdocuments.in/reader035/viewer/2022081507/589afaff1a28ab3e288b6815/html5/thumbnails/18.jpg)
Storage areas Storage areas of sufficient capacity Orderly storage of categories of materials and
products Separate and segregated areas: starting
materials, packaging materials, intermediates, bulk, finished products, quarantined, released, rejected, returned and recalled products and materials
![Page 19: Gmp premicses](https://reader035.fdocuments.in/reader035/viewer/2022081507/589afaff1a28ab3e288b6815/html5/thumbnails/19.jpg)
![Page 20: Gmp premicses](https://reader035.fdocuments.in/reader035/viewer/2022081507/589afaff1a28ab3e288b6815/html5/thumbnails/20.jpg)
Storage areas Appropriate temperature and relative humidity
conditions within defined limitsProvided, controlled, monitored and recorded
Good storage conditions: clean, dry and appropriate lights
![Page 21: Gmp premicses](https://reader035.fdocuments.in/reader035/viewer/2022081507/589afaff1a28ab3e288b6815/html5/thumbnails/21.jpg)
Storage areas Quarantine area: clearly marked and access
restricted A separate sampling area is the norm: no risk
for contamination or cross-contamination Segregated areas for rejected, recalled and
returned materials and products Safe and secure areas for highly active,
radioactive materials, narcotics and other materials (risk of abuse, fire, explosion)
![Page 22: Gmp premicses](https://reader035.fdocuments.in/reader035/viewer/2022081507/589afaff1a28ab3e288b6815/html5/thumbnails/22.jpg)
![Page 23: Gmp premicses](https://reader035.fdocuments.in/reader035/viewer/2022081507/589afaff1a28ab3e288b6815/html5/thumbnails/23.jpg)
QC laboratories should be separate from production areas
Separate areas for biological, microbiological and radioisotope methods
Suitable design with sufficient space to avoid mix-ups and cross-contamination
Suitable space for storage samples, reference standards, solvents, reagents and records
Quality Control areas
![Page 24: Gmp premicses](https://reader035.fdocuments.in/reader035/viewer/2022081507/589afaff1a28ab3e288b6815/html5/thumbnails/24.jpg)
Quality Control areas Suitable construction materials Prevention of fumes Ventilation Separate air supply (production and QC) Separate rooms for some instruments to
protect them from interference (e.g. electrical, vibration, moisture, etc.)
See supplementary training on QC laboratories
![Page 25: Gmp premicses](https://reader035.fdocuments.in/reader035/viewer/2022081507/589afaff1a28ab3e288b6815/html5/thumbnails/25.jpg)
Health, clothing ,sanitation of workers – The personnel handling Beta-lactum antibiotics shall be tested for Penicillin
sensitivity before employment and those handling sex hormones, cytotoxic substances and
other potent drugs shall be periodically examined for adverse effects. These personnel should
be moved out of these sections (except in dedicated facilities), by rotation, as a health
safeguard. Prior to employment, all personnel, shall undergo medical examination including eye
examination, and shall be free from Tuberculosis, skin and other communicable or contagious
diseases. Thereafter, they should be medically examined periodically, at least once a year.
Records shall be maintained thereof. The licensee shall provide the services of a qualified
physician for assessing the health status of personnel involved in different activities. All persons, prior to and during employment, shall be trained in practices which
ensure personnel hygiene. A high level of personal hygiene shall be observed by all those
engaged in the manufacturing processes. Instructions to this effect shall be displayed in
change-rooms and other strategic locations.
![Page 26: Gmp premicses](https://reader035.fdocuments.in/reader035/viewer/2022081507/589afaff1a28ab3e288b6815/html5/thumbnails/26.jpg)
![Page 27: Gmp premicses](https://reader035.fdocuments.in/reader035/viewer/2022081507/589afaff1a28ab3e288b6815/html5/thumbnails/27.jpg)
No person showing, at any time, apparent illness or open lesions which may adversely affect the quality of products, shall be allowed to handle starting materials, packaging materials, in-process materials, and drug products until his condition is no longer judged to be a risk.
All employees shall be instructed to report about their illness or abnormal health condition to their immediate supervisor so that appropriate action can be taken.
Direct contact shall be avoided between the unprotected hands of personnel and raw materials, intermediate or finished, unpacked products
![Page 28: Gmp premicses](https://reader035.fdocuments.in/reader035/viewer/2022081507/589afaff1a28ab3e288b6815/html5/thumbnails/28.jpg)
Environmental Monitoring –
All environmental parameters shall be verified and established at the
time of installation and thereafter monitored at periodic intervals.
The recommended frequencies of periodic monitoring shall be as follows:
( a ) Particulate monitoring in air – 6 Monthly
(b) HEPA filter integrity testing (smoke testing) – Yearly
(c) Air change rates – 6 monthly
(d) Air pressure differentials – Daily
(e) Temperature and humidity – Daily
(f) Microbiological monitoring by settle plates and/or swabs in aseptic
![Page 29: Gmp premicses](https://reader035.fdocuments.in/reader035/viewer/2022081507/589afaff1a28ab3e288b6815/html5/thumbnails/29.jpg)
Class 100 Area - parentrals
Class 1000 Area- manufactring,production
Class 10000 Area-filling,sealing.
Class 100000 Area-packaging,labeling.
STERILE AREAS
![Page 30: Gmp premicses](https://reader035.fdocuments.in/reader035/viewer/2022081507/589afaff1a28ab3e288b6815/html5/thumbnails/30.jpg)
Terminally Sterilized Products – Preparation of primary packaging material such as glass bottles, ampoules
andrubber stoppers shall be done in at least Grade D environment. Where there isunusual risk to the product from microbial contamination, the above operationshall be done in Grade C environment. All the processes used for componentpreparation shall be validated. Filling of products requiring terminal sterilization shall be done under GradeA environment with a Grade C background. Preparation of solutions, which are to be sterilized by filtration, shall be donein Grade C environment, and if not to be filtered, the preparation of materialsand products shall be in a Grade A environment with Grade B in background. Filtration ( Membrane )—( i ) Solutions for Large Volume Parenterals shall be filtered through a nonfiberreleasing, sterilizing grade cartridge/membrane filter of nominal poresize of 0.22 μ for aseptic filling whereas 0.45 μ porosity shall be used forterminally sterilized products
![Page 31: Gmp premicses](https://reader035.fdocuments.in/reader035/viewer/2022081507/589afaff1a28ab3e288b6815/html5/thumbnails/31.jpg)
ii ) A second filtration using another 0.22 μ sterilizing grade
cartridge/membrane filter shall be performed immediately prior tofilling. Process specifications shall indicate the maximum time duringwhich a filtration system may be used with a view to precludingmicrobial build-up to levels that may affect the microbiological qualityof the Large Volume Parenterals.( iii ) The integrity of the sterilized filter shall be verified and
confirmedimmediately after use by an appropriate method such as Bubble
Point,Diffusive Flow or Pressure Hold Test.
![Page 32: Gmp premicses](https://reader035.fdocuments.in/reader035/viewer/2022081507/589afaff1a28ab3e288b6815/html5/thumbnails/32.jpg)