Glycol Pumps
Transcript of Glycol Pumps
-
Glycol PumpsProduct Selection Guide
Con iguration o Glycol Pump is a trademark o Kimray, nc
4-1
-
Dry Glycol
Wet Glycol
Dry Glycol
Wet Glycol
Reboiler
Heat ExchangerSurge Tank
Pump
Wetgasin
Drygasout
Absorber(Contactor)
Natural GasWet natural gas enters the bottom of the absorber. It flows upward through a packed bed or through a series of bubble cap or valve trays filled with glycol where thorough contact is made. The gas gives up water vapor to the glycol as it passes upward and leaves the absorber as dry gas ready to enter the sales line.
GlycolThe dry concentrated glycol is continuously pumped to the top tray of the absorber. As the glycol moves down-ward from tray to tray it absorbs the water vapor from the rising gas stream. The wet glycol is then removed at the bottom of the absorber and pumped through a large preheating coil in the surge tank. It then enters the still column at the top of the reboiler where the water vapor is stripped away as steam.
The regenerated glycol spills down into the surge tank and is pumped to the top of the absorber to start another cycle.
Glycol PumpThe Glycol Pump takes glycol at absorber pressure, moves it into the reboiler at atmospheric pressure, and then returns it to pressure adequate to drive the glycol back into the abosrber. All this is accomplished by utilizing some of the gas at absorber pressure to drive the system without an additional source of outside energy.
The Glycol Pump operates in various demanding conditions: high temperature, high pressure, varied chemical contaminates, and potential of a wide range of abrasive materials.
Nearly 50 years of demanding service have proven the ruggedness and dependability of the unique and robust design.
4-2
Glycol PumpsDehydrator
-
Function: Circulates glycol in a dehydration system.Circulates amine in a desulphurizer system.Utilizes the energy of gas and glycol at absorber pres-sure as its source of power.
Features:No auxiliary power requiredEliminates need for level control and dump valve at absorberLow gas consumptionCompletely sealed system prevents glycol lossOnly two moving assembliesHydraulic cushioned check valves with removable seats of hardened stainless steel
Circulation Rates: SC Series 8 - 200 gph PV Series 3 - 450 gph
Working Pressure: 1500 psig
Options:Elastomers: HSN, Viton, Aflas
Metal Materials: 316 Stainless Steel, 17-4 PH Stainless Steel
High Pressure PV
Low Pressure (Small Cylinder) SC
ModelNumber
CapacityGallons / Hour
WorkingPressure
Minimum Maximum Minimum Maximum 315 PV 1715 PV 4015 PV 9015 PV21015 PV45015 PV
3 8 12 27 66166
13 40 40 90210450
100300300300400400
150015001500150015001500
ModelNumber
CapacityGallons / Hour
WorkingPressure
Minimum Maximum Minimum Maximum 2015 SC 5015 SC10015 SC20015 SC
8 12 22 60
20 50100200
100100100100
500500500500
Features:Sock type elementIn line filter removal1/4 NPT Bleed Valve connectionHammer union capSolid mount3/4 NPT inlet and outlet connections
Temperature Range: -20 to 650oF
Working Pressure: 1500 psig
Recommended Pumps: 315PV4015PV9015PV2015SC5015SC
Used to filter particles of rust, sludge and debris from theglycol lines before the glycol reaches the pumping system. This allows the glycol pump to operate more freely and reduc-es pump wear. The filter itself is disposable and can easily be replaced.
Glycol Filter Canister
4-3
Glycol Pumps
Con iguration o Glycol Pump is a trademark o Kimray, nc
-
Dehydration Equipment
4-4
Liquid Level Control
GEN II Liquid Level Controller
Supply Pressure: 0-35 psig maximum
Vessel Operating Pressure: 50 to 4000 psig maximum
Temperature Range: -20 to 200oFOptional elastomers provide higher maximum temperature
Float Travel:3/4 maximum
Features:
Compact Design: installs inside a smaller turning space than brand F or N
Low Friction Waggle Arm: no rotatingstuffing box and related friction/stiction
Snap or Throttle control in one pilot:simple adjustment to change from snap to throttle control with the turn of a knob.
Intermittent-Bleed pilot meets BMP standards specified in the EPA Natural Gas Star Program.
Built-in 40 micron supply gas filter
Vibration Tough
1/4 NPT Tapped Vented Pilot: Easy to connect and pipe exhaust away if needed.
Vertical or Horizontal Displacer: field configurable
Universal Level Control ULC
Features:Direct actingIntermittent bleed pilotSimple installationEasy to useNo adjustment required.65 specific gravity or higher
Bodies Available:1 NPT Brass, Steel, or Stainless Steel2 NPT Steel or Stainless Steel
Maximum W.P.: 1500 psig
Supply Pressure: 30 psig max.
Maximum Temperature: 200oF
Options:Low density, high temperature floatVertical float adapter
Other Kimray dehydration equipment:
Liquid Level Controls Dump Valves Thermostats Burner Valves Pressure Regulators
THERES A LOT MORE TO GAS DEHYDRATION THAN THE KIMRAY GLYCOL PUMP!
Original Side MountGEN II
GEN II Back Mount
-
4-5
Angle or Thru valve bodyCarbide trimIdeal for high pressure differentialOn / Off service
Valve AvailableConnection Orifice Sizes 1 1/8, 3/16, 1/4, 3/8 2 1/4, 3/8, 1/2, 3/4, 1
Non-Freeze High Pressure Dump Valve
The Non-Freeze Dump Valve places the trim inside the vessel in direct contact with the process liquid, preventing freezing within the valve.
Valve Available Carbide Orifice SizesConnection 1 Inlet & Outlet 1/4, 3/8, 1/2 2 Vessel Mounting
Standard actuator has an effective dia-phragm area of 30 square inches.
65 Topworks has an effective area of 65 square inches, which allows a wider adjustable spring range.
Maximum Pressure Drop:
SMS - 1/4 - 2000 psi 3/8 - 800 psi 1/2 - 450 psi
65 SMS - 1/4, 3/8, 1/2 - 4000 psi
SMS
65 SMS
Adjustable Pressure Opening SMT ADA
Spring Closing Pressure Opening SMT DAB
Pressure opening Burner Valve used where a reduced inner valve is desired and manifold pressures do not exceed 25 psig.
Pressure opening Burner Valve for throt-tling or snap action service and where manifold pressures do not exceed 40 psig.
High Pressure Motor ValveSizes available:1 NPT, Flanged - Angle or Through Body2 NPT, Flanged - Angle or Through Body
Non-Freeze Motor Valve Size available:1 NPT Inlet & Outlet2 Vessel Mounting
Maximum Working Pressure: 4000 psi
Temperature Range: -20o to 200o F
Options:Elastomers: HSN, Viton, AflasTrim Material: Stainless Steel, Carbide
Valve High PressureMotor Valve
Non-Freeze HighPressure Dump
Body Steel SteelStem 303 Stainless 303 StainlessPlug 303 Stainless CarbideCage Steel SteelActuator Ductile Iron Ductile IronSeat Steel D2 Steel or CarbideDiaphragms Nitrile/Nylon Nitrile/Nylon
Normal Service: LiquidsFeatures:Quick opening trimTravel indicatorAvailable in Pressure Opening or Pressure ClosingField reversible actuatorTeflon packed stuffing box requires no lubricationOpen yoke design - accurate travel indication - complete isolation of actuator
Normal Service: LiquidsFeatures:Equal Percentage trimSoft seat for bubble tight shut-offSpecial stem seal requires no lubrication
Sizes available:1 NPT2 NPT, Flanged
Temperature Range: -20o to 200o F
Options:Elastomers: HSN, Viton, Aflas
Trim Material: 316 Stainless Steel internal partsOrifice Size: LIne size or reduced
Construction Materials:Body Cast Iron Ductile Iron SteelDesignPressure
Scrd. 175 psiFlgd. 175 psi
Scrd. 300 psiFlgd. 250 psi Flgd. 285 psi
Stem 303 Stainless 303 Stainless 303 StainlessPlug Ductile Iron Ductile Iron SteelSeat Nitrile Polyurethane PolyurethaneDiaphragms Nitrile/Nylon Nitrile/Nylon Nitrile/Nylon
High Pressure Motor Valve
Construction Materials:
Dehydration EquipmentDump Valves and Burner Valves
Con iguration o High Pressure Motor Valve is a trademark o Kimray, nc
THERES A LOT MORE TO GAS DEHYDRATION THAN THE KIMRAY GLYCOL PUMP!
-
Thermostat Features:Single adjustmentHigh accuracyIntermittent-bleed constructionBi-metalic sensing element
Supply Pressure: 5 to 30 psig
Working Pressure (sensing element): 500 psig without Separable Socket4000 psig with Separtable Socket7000 psig with Special Separable Socket
Separable socket is an extra price item and is ordered separately.
Temperature Range:T 12, T 18 -30o to 400o F -34o to 204o CHT 12, HT 18 -30o to 750o F -34o to 399o CPilot Guard -30o to 2100o F -34o to 1149o C
Options:Elastomers: HSN, Viton, Aflas
Metal Material: 316 Stainless Steel internal exposed parts
Indirect Acting Thermostats:Output decreases with temperature rise.
Indirect control of burner valves,mixing valves, air shutters
Indirect Throttle Thermostat T 12
For temperature controlled system shutdown until manually resetShuts off when system temperature exceeds setpoint
Indirect High Temperature Shut-Down T 12M
Indirect action for systemshut-down when pilot flame goes out. Also used in direct mode for high stack temperture shutdown
Pilot Guard HT12 PG
Maintains constant downstream pressure. Provides a supply of constant reduced pressure for pneumatic instruments and pilot operated controllers.
Supply Gas Regulator Features:
Easily adjustedInternally relievingAvailable in Aluminum and 316 Stainless Steel
Connections:
Inlet and Outlet - 1/4 NPT
Operating Temperature:
0o to 200oF (-18oC to 93oC)
Maximum Inlet Pressure:4000 psi
Outlet Pressure:0 to 125 psi
Construction Materials:Body: Aluminum or 316 Stainless SteelDiaphragm: PolyurethaneSeat: Nylon
4-6
Supply Gas Regulator SGR
Dehydration EquipmentThermostats & Supply Gas Regulator
THERES A LOT MORE TO GAS DEHYDRATION THAN THE KIMRAY GLYCOL PUMP!