GloBug Light Towers · power cable Three-stage mast ... point lifting without removing attachments....
-
Upload
vuongthien -
Category
Documents
-
view
215 -
download
0
Transcript of GloBug Light Towers · power cable Three-stage mast ... point lifting without removing attachments....
www.multiquip.comConstruction Starts Here
See the light.
GloBug Light Towers™
You've seen the light.
Your Multiquip dealer is:
All features and specifications are subject to change without notice.GLOBUG-405 (04-06) www.multiquip.com
see the light.
GB114BC
Looking in the light's direction during at night-time, you may be dazzled and blinded for a while. Balloon lighting of GloBugTM series gives enough light to the work site but no unplesantness to the surrounding traffic.
MULTIQUIP INC.POST OFFICE BOX 6254CARSON, CA 90749310-537-3700 900-421-1244FAX: 310-537-3927E-MAIL: [email protected]
GloBug Lighting System
GlowBug Solo is easily transportable; protective canvas balloon cover is included as standard.
Quick disconnect power cable
Three-stage mast with extension pole
Gas shock absorbers for easy lifting
Caster wheels with stoppers
Lifting hook
Locking latch — locks mast at desired height
Removable ballast box
Five outriggers for stabilization
Counterweights lock outriggers into place
Extra 30" extension pole
360° glare-free lighting
Up to 13' 1" tall
GloBug SoloWhen space is limited but illumination is required, call on the Multiquip GloBug Solo GB-114BW
Protective canvas cover stores balloon while not in use.
n Metal Halide lamp — single 1,000 watt lamp for maximum illumination. Pure white light — 3400° K.
n 360° glarefree illumination with standard balloon (BAL120).
n Stainless steel construction.
n Downward direct illumination with reflector balloon.
n Self-inflating balloons are easy to install and inflate in less than 20 seconds.
n Three-stage mast with extension pole — extends up to 13' 1".
n Caster wheels with stoppers for easy maneuverability.
n Five outriggers for great stabilization.
n Light coverage up to 150 feet.
Stainless steel construction for long life and easy maintenance
EFFICIENT DESIGNThe light is easily moved as construction progresses to provide a safe work environment for workers.
SAFE FOR VEHICLE TRAFFICDrivers are not blinded by the intense glare of conventional light towers, helping improve roadway safety.
SAFE FOR CONSTRUCTION CREWSThe glare-free lighting benefits work crews by improving visibility and eliminating blind spots.
Equipment-Mount GB114BS
EASY SET UPGas-assisted mast allows the balloon to be raised with minimal effort. A counterweight locks the outrigger into place automatically.
EASY HANDLINGThe work stand has five caster wheels for easy maneuverability. The well balanced design allows single point lifting without removing attachments.
SAFE DESIGNFive outriggers provide excellent stabilization. The gas-assisted mast prevents it from coming down unexpectedly when raising or lowering.
Easy lifting with Gas-assisted mast
Five outriggers for excellent stabilization; five caster wheels for smooth transit.
GloBug Solo GB114BW
Flexible Clamps allow installation at any angle
GloBug Lighting SystemCart Type GB114BC
DESIGNED FOR CONSTRUCTION APPLICATIONSThe balloon, mast and cart are all designed to withstand the rigors of the jobsite.
Impact-Resistant FrameVibration-Proof Lamp
Durable, Heatproof and Washable Fabric
EXCELLENT MANEUVERABILITYPneumatic tires and a T-bar steering handle allow easily handling on the jobsite.
Parking BrakeSteering Handle
Brake Pedal Brake Pad
EASY TRANSPORTATIONOne truck can transport several GloBugs for reduced transportation costs.
4 units of GB114BC can be transported by a 6' x 8' trailer
EXCELLENT WIND STABILITYGloBug’s unqique “One-Touch Outriggers” are quickly set and automatically lock into place. No special handling is required.
GB114BC GB114BW Wind Tunnel test
Unit shown with optional generator.
Shown with optional generator
Quick-disconnect power cable
Reflector maximizes downlighting (BAL-120R balloon only)
Protective canvas cover stores balloon while not in use
Optional drum-shaped balloon with Velcro strips to hold warning or promotional messages — installs quickly with no tools
360° glare-free lighting
Four-stage mastTilting grip handle
Lifting hook for easy transportSafety winch prevents mast from
collapsing
Handle bar for easy transportation
Counterweights lock outriggers into place
Parking brake
Internal ballast for safety
Pneumatic tires for easy maneuverability
Outriggers for stabilization (shown in their undeployed state)
Optional generator
Multiquip’s GB-114BC GloBug Lighting System is designed to provide glare-free lighting for a wide range of applications.
n Metal Halide lamp — one 1,000 watt lamp for maximum illumination.
n 360° glare-free illumination with standard balloon (BAL-120).
n Downward direct illumination with reflector balloon.
n Self-inflating balloons are easy to install and change; inflate in less than 20 seconds.
n Four-stage mast extends to 16.5 feet.
n Steerable cart.
Use GloBug Solo on these and other applications:n Disaster reliefn Night parkingn Emergency repairsn Landscapingn Farming and agriculture ...and many more
n Road constructionn Search and rescuen Special eventsn Parking lot lightingn Partiesn Maintenancen Mining
Stainless steel construction for long life and easy maintenance
GloBug Lighting System
Material of Balloon Envelope
Replacing
Washing
BALLOON ENVELOPE
The fan motor (blower) that inflates the balloon also acts as a cooling function. If the fan motor should break, Balloon alarm buzzer installed acts as a safety device. It will sound during normal operation if the balloon attempts to make contact with the lamp’s hot! surface. If this condition occurs, immediately place the GloBug’s ON/OFF switch in the OFF position.
Expendable parts such as balloon envelope and lamp can be quickly replaced without any tools and with less effort. Adjusting angle of the balloon, that is to change the illumination area, and storing balloon are operated easily.
The fabric made of a special material is very resistant to heat. As the test results show below, the fabric does not melt with any temperature at each part.
As a material of the balloon envelope of GloBugTM series, the most suitable fabric, is well diffusive, durable and heatproof, is selected. Maintenance to the balloon envelope is possible, making it last for a long time.
Common dirt such as mud will come out in washing machines. Detach the envelope from the balloon and put it in a laundry bag. You can wash it readily with most neutral detergent. In the case of greasy dirt, wipe off the dirt using grease and oil cleaning sprays and wash it in a washing machines.
Heatproof of balloonHeat resistanttemperature
320 to 360°F
Meltingtemperature
500°F
0°F 100°F 400°F
Surfaceof lamp
Lamp guard
Internal airof balloon
Surface of lampInternal air of balloon
Lamp guard
Thermostat
1. Unzip the zipper at the bottom and top of the balloon.
2. Remove the balloon envelope and cover with a new one.
3. Zip up the zipper.
FEATURES OF BALLOON LIGHT
Lumens
12,000hr
400hr
8.3A33.5A
8.50USD
128.00USD
Life hours
Required amperages
Annual Cost
■ LARGE LIGHT SOURCE FOR HIGH VISIBLITYBalloon Light is safe for surrounding traffic as large light is highly visible and seen from afar. The light that forms less darker shadow is also comfortable for the workers.
■ LONG-LIVED HIGH EFFICIENCY LAMP
Comparison between Metal halide and Halogen
HEATPROOF
Metal halide lamp being used for GloBugTM is high efficiency, longer life and stronger to vibration compared with Halogen lamp.
■ MESSAGE STRIP FOR ATTENTION (OPTION)Since it has integral Velcoro strips, message strip can be quickly installed with no tools. Special occasion balloon are avalable or design your won
As most of balloon lights that adopt halogen use 1000W x 2 bulbs, some comparisons with metal halides are counted with 2 halogen bulbs.
Message Strips fit on both sides of the balloon.
*7 hours/day x 365days
104,500lm
52,000lm (26,000lm x 2) 200%200%approx.approx.
Higher Light OutputHigher Light Output
1/41/4approx.approx.
More Energy CoservationMore Energy Coservation
1/151/15approx.approx.
Lower Cost ReductionLower Cost Reduction
3000%3000% Longer LifeLonger Lifeapprox.approx.
Metal halide lampHalogen lamp
GloBug Lighting System
Material of Balloon Envelope
Replacing
Washing
BALLOON ENVELOPE
The fan motor (blower) that inflates the balloon also acts as a cooling function. If the fan motor should break, Balloon alarm buzzer installed acts as a safety device. It will sound during normal operation if the balloon attempts to make contact with the lamp’s hot! surface. If this condition occurs, immediately place the GloBug’s ON/OFF switch in the OFF position.
Expendable parts such as balloon envelope and lamp can be quickly replaced without any tools and with less effort. Adjusting angle of the balloon, that is to change the illumination area, and storing balloon are operated easily.
The fabric made of a special material is very resistant to heat. As the test results show below, the fabric does not melt with any temperature at each part.
As a material of the balloon envelope of GloBugTM series, the most suitable fabric, is well diffusive, durable and heatproof, is selected. Maintenance to the balloon envelope is possible, making it last for a long time.
Common dirt such as mud will come out in washing machines. Detach the envelope from the balloon and put it in a laundry bag. You can wash it readily with most neutral detergent. In the case of greasy dirt, wipe off the dirt using grease and oil cleaning sprays and wash it in a washing machines.
Heatproof of balloonHeat resistanttemperature
320 to 360°F
Meltingtemperature
500°F
0°F 100°F 400°F
Surfaceof lamp
Lamp guard
Internal airof balloon
Surface of lampInternal air of balloon
Lamp guard
Thermostat
1. Unzip the zipper at the bottom and top of the balloon.
2. Remove the balloon envelope and cover with a new one.
3. Zip up the zipper.
FEATURES OF BALLOON LIGHT
Lumens
12,000hr
400hr
8.3A33.5A
8.50USD
128.00USD
Life hours
Required amperages
Annual Cost
■ LARGE LIGHT SOURCE FOR HIGH VISIBLITYBalloon Light is safe for surrounding traffic as large light is highly visible and seen from afar. The light that forms less darker shadow is also comfortable for the workers.
■ LONG-LIVED HIGH EFFICIENCY LAMP
Comparison between Metal halide and Halogen
HEATPROOF
Metal halide lamp being used for GloBugTM is high efficiency, longer life and stronger to vibration compared with Halogen lamp.
■ MESSAGE STRIP FOR ATTENTION (OPTION)Since it has integral Velcoro strips, message strip can be quickly installed with no tools. Special occasion balloon are avalable or design your won
As most of balloon lights that adopt halogen use 1000W x 2 bulbs, some comparisons with metal halides are counted with 2 halogen bulbs.
Message Strips fit on both sides of the balloon.
*7 hours/day x 365days
104,500lm
52,000lm (26,000lm x 2) 200%200%approx.approx.
Higher Light OutputHigher Light Output
1/41/4approx.approx.
More Energy CoservationMore Energy Coservation
1/151/15approx.approx.
Lower Cost ReductionLower Cost Reduction
3000%3000% Longer LifeLonger Lifeapprox.approx.
Metal halide lampHalogen lamp
GloBug Lighting System
Spot Light Balloon Light
Spot Light — Worksite visibility is reduced due to the intense glare.
Balloon Light — The balloon illuminates the entire site; workers can see clearly beyond the site for improved safety.
EXCELLENT VISIBILITYThe balloon is highly visible when the mast is fully extended, improving safety. Its unique design reduces shadows in the work area.
HIGH QUALITY LAMPMetal halide lamps offer high efficiency with longer life and better vibration resistance compared to halogen lamps.
Comparison of metal halide vs. halogen lamps
Note: Manufacturers using halogen lamps typically use two 1000 watt bulbs
Lumens
Life (hours)
Required amperage
Annual Cost
MESSAGE STRIPSCustom messages are easily applied using Velcro® fasteners. Special occasion balloons are also available.
BLIND SPOT-FREE WORK AREA Light output from the balloon radiates a full 360 degrees without a blind spot. Special balloons are available for work in confined spaces or in residential areas.
GLARE-FREE LIGHTING FOR TRAFFFIC SAFETYGloBug lighting systems offer superior illumin ation for construction crews along highways. Motorists are not subjected to the intense glare produced by conventional light towers — even when looking directly at the light.
WIDE COVERAGE AREAConventional light towers concentrate light in a fixed direction. GloBug radiates its light evenly all the way around the balloon.
■ GLARE-FREE LIGHTING FOR TRAFIC SAFETY
Features of Balloon Light
Spot ligh Balloon Light Coverage Range of GB113BC
Spot Light Balloon Light
GloBugTM Lighting System gives enough light to a work area but eyes are never blinded by glare even if seeing the light directly. It is gentle to surrounding traffic.
■ WIDE COVERAGE RANGE WITH HOMOGENEOUS LIGHTINGCompared to Traditional Spotlight towers that concentrate the light to a fixed direction, GloBugTM series can radiate the homogeneous light far and wide from the balloon to all directions.
■ 360°ILLUMINATION WITHOUT BLIND SPOTComing from the whole balloon, the light reaches over 360 degrees and to a long distance homogeneously. Illuminating fixed direction or close to residential area, you can use a reflector balloon.
Facing back light, you cannot see conditions of the road behind the light.
As the balloon illuminates the whole area of the site, you can see conditions beyond the site. So it is safe.
Unit: footcandle, 1 grid: 50ft.
with Traditional Light Tower
with Balloon light competitor
Compared to traditional 1000W x 4 class of light tower (Spotlight type), GloBugTM series can illuminate a large area with more homogeneous light, even though the required power is the quarter at only 1000W. You can illuminate with safer and non-glare light at low cost since GloBugTM series eats much less fuel than 4000W class of light towers do. The followings is a comparison between Traditional light tower & GloBugTM "Cart type - GB114BC".
Compared to competitors's balloon lighting system such as Ingersoll Rand Balloon Light "BL2000" the light of GloBugTM series reaches further. For example, when BL2000 illuminates 15,000 sqft., GloBugTM “Cart type - GB114BC" can illuminate 30,000 spft. with the same brightness.
COVERRAGE RANGE
GB114BCDrum Shaped Balloon
Traditinal light tower1000W x 4 lamps
GB114BCStandard Balloon
GB114BCReflector Balloon
Distance from Light Souce
Illum
inat
ion
(Foo
t-can
dle)
15 feet
9.0
17.8
22.2
26.9
30 feet
2.86.6 7.56.7
45 feet
1.42.9 3.22.7
60 feet
0.91.7 1.91.5MQ "G
loBu
g" w
ith D
rum
Sha
ped
Ballo
onMQ
"Glo
Bug"
with
Reg
lecto
r Ball
oon
MQ "G
loBu
g" w
ith S
tand
ard
Ballo
on
IR "B
L200
0"
3 feet
22.3
36.4
54.8
94.8
GloBug Lighting System COMPARISON
■ GLARE-FREE LIGHTING FOR TRAFIC SAFETY
Features of Balloon Light
Spot ligh Balloon Light Coverage Range of GB113BC
Spot Light Balloon Light
GloBugTM Lighting System gives enough light to a work area but eyes are never blinded by glare even if seeing the light directly. It is gentle to surrounding traffic.
■ WIDE COVERAGE RANGE WITH HOMOGENEOUS LIGHTINGCompared to Traditional Spotlight towers that concentrate the light to a fixed direction, GloBugTM series can radiate the homogeneous light far and wide from the balloon to all directions.
■ 360°ILLUMINATION WITHOUT BLIND SPOTComing from the whole balloon, the light reaches over 360 degrees and to a long distance homogeneously. Illuminating fixed direction or close to residential area, you can use a reflector balloon.
Facing back light, you cannot see conditions of the road behind the light.
As the balloon illuminates the whole area of the site, you can see conditions beyond the site. So it is safe.
Unit: footcandle, 1 grid: 50ft.
with Traditional Light Tower
with Balloon light competitor
Compared to traditional 1000W x 4 class of light tower (Spotlight type), GloBugTM series can illuminate a large area with more homogeneous light, even though the required power is the quarter at only 1000W. You can illuminate with safer and non-glare light at low cost since GloBugTM series eats much less fuel than 4000W class of light towers do. The followings is a comparison between Traditional light tower & GloBugTM "Cart type - GB114BC".
Compared to competitors's balloon lighting system such as Ingersoll Rand Balloon Light "BL2000" the light of GloBugTM series reaches further. For example, when BL2000 illuminates 15,000 sqft., GloBugTM “Cart type - GB114BC" can illuminate 30,000 spft. with the same brightness.
COVERRAGE RANGE
GB114BCDrum Shaped Balloon
Traditinal light tower1000W x 4 lamps
GB114BCStandard Balloon
GB114BCReflector Balloon
Distance from Light Souce
Illum
inat
ion
(Foo
t-can
dle)
15 feet
9.0
17.8
22.2
26.9
30 feet
2.86.6 7.56.7
45 feet
1.42.9 3.22.7
60 feet
0.91.7 1.91.5MQ "G
loBu
g" w
ith D
rum
Sha
ped
Ballo
onMQ
"Glo
Bug"
with
Reg
lecto
r Ball
oon
MQ "G
loBu
g" w
ith S
tand
ard
Ballo
on
IR "B
L200
0"
3 feet
22.3
36.4
54.8
94.8
GloBug Lighting System COMPARISON■ GLARE-FREE LIGHTING FOR TRAFIC SAFETY
Features of Balloon Light
Spot ligh Balloon Light Coverage Range of GB113BC
Spot Light Balloon Light
GloBugTM Lighting System gives enough light to a work area but eyes are never blinded by glare even if seeing the light directly. It is gentle to surrounding traffic.
■ WIDE COVERAGE RANGE WITH HOMOGENEOUS LIGHTINGCompared to Traditional Spotlight towers that concentrate the light to a fixed direction, GloBugTM series can radiate the homogeneous light far and wide from the balloon to all directions.
■ 360°ILLUMINATION WITHOUT BLIND SPOTComing from the whole balloon, the light reaches over 360 degrees and to a long distance homogeneously. Illuminating fixed direction or close to residential area, you can use a reflector balloon.
Facing back light, you cannot see conditions of the road behind the light.
As the balloon illuminates the whole area of the site, you can see conditions beyond the site. So it is safe.
Unit: footcandle, 1 grid: 50ft.
with Traditional Light Tower
with Balloon light competitor
Compared to traditional 1000W x 4 class of light tower (Spotlight type), GloBugTM series can illuminate a large area with more homogeneous light, even though the required power is the quarter at only 1000W. You can illuminate with safer and non-glare light at low cost since GloBugTM series eats much less fuel than 4000W class of light towers do. The followings is a comparison between Traditional light tower & GloBugTM "Cart type - GB114BC".
Compared to competitors's balloon lighting system such as Ingersoll Rand Balloon Light "BL2000" the light of GloBugTM series reaches further. For example, when BL2000 illuminates 15,000 sqft., GloBugTM “Cart type - GB114BC" can illuminate 30,000 spft. with the same brightness.
COVERRAGE RANGE
GB114BCDrum Shaped Balloon
Traditinal light tower1000W x 4 lamps
GB114BCStandard Balloon
GB114BCReflector Balloon
Distance from Light Souce
Illum
inat
ion
(Foo
t-can
dle)
15 feet
9.0
17.8
22.2
26.9
30 feet
2.86.6 7.56.7
45 feet
1.42.9 3.22.7
60 feet
0.91.7 1.91.5MQ "G
loBu
g" w
ith D
rum
Sha
ped
Ballo
onMQ
"Glo
Bug"
with
Reg
lecto
r Ball
oon
MQ "G
loBu
g" w
ith S
tand
ard
Ballo
on
IR "B
L200
0"
3 feet
22.3
36.4
54.8
94.8
GloBug Lighting System COMPARISON
GloBug Lighting System
Material of Balloon Envelope
Replacing
Washing
BALLOON ENVELOPE
The fan motor (blower) that inflates the balloon also acts as a cooling function. If the fan motor should break, Balloon alarm buzzer installed acts as a safety device. It will sound during normal operation if the balloon attempts to make contact with the lamp’s hot! surface. If this condition occurs, immediately place the GloBug’s ON/OFF switch in the OFF position.
Expendable parts such as balloon envelope and lamp can be quickly replaced without any tools and with less effort. Adjusting angle of the balloon, that is to change the illumination area, and storing balloon are operated easily.
The fabric made of a special material is very resistant to heat. As the test results show below, the fabric does not melt with any temperature at each part.
As a material of the balloon envelope of GloBugTM series, the most suitable fabric, is well diffusive, durable and heatproof, is selected. Maintenance to the balloon envelope is possible, making it last for a long time.
Common dirt such as mud will come out in washing machines. Detach the envelope from the balloon and put it in a laundry bag. You can wash it readily with most neutral detergent. In the case of greasy dirt, wipe off the dirt using grease and oil cleaning sprays and wash it in a washing machines.
Heatproof of balloonHeat resistanttemperature
320 to 360°F
Meltingtemperature
500°F
0°F 100°F 400°F
Surfaceof lamp
Lamp guard
Internal airof balloon
Surface of lampInternal air of balloon
Lamp guard
Thermostat
1. Unzip the zipper at the bottom and top of the balloon.
2. Remove the balloon envelope and cover with a new one.
3. Zip up the zipper.
FEATURES OF BALLOON LIGHT
Lumens
12,000hr
400hr
8.3A33.5A
8.50USD
128.00USD
Life hours
Required amperages
Annual Cost
■ LARGE LIGHT SOURCE FOR HIGH VISIBLITYBalloon Light is safe for surrounding traffic as large light is highly visible and seen from afar. The light that forms less darker shadow is also comfortable for the workers.
■ LONG-LIVED HIGH EFFICIENCY LAMP
Comparison between Metal halide and Halogen
HEATPROOF
Metal halide lamp being used for GloBugTM is high efficiency, longer life and stronger to vibration compared with Halogen lamp.
■ MESSAGE STRIP FOR ATTENTION (OPTION)Since it has integral Velcoro strips, message strip can be quickly installed with no tools. Special occasion balloon are avalable or design your won
As most of balloon lights that adopt halogen use 1000W x 2 bulbs, some comparisons with metal halides are counted with 2 halogen bulbs.
Message Strips fit on both sides of the balloon.
*7 hours/day x 365days
104,500lm
52,000lm (26,000lm x 2) 200%200%approx.approx.
Higher Light OutputHigher Light Output
1/41/4approx.approx.
More Energy CoservationMore Energy Coservation
1/151/15approx.approx.
Lower Cost ReductionLower Cost Reduction
3000%3000% Longer LifeLonger Lifeapprox.approx.
Metal halide lampHalogen lamp
GloBug Lighting System
Material of Balloon Envelope
Replacing
Washing
BALLOON ENVELOPE
The fan motor (blower) that inflates the balloon also acts as a cooling function. If the fan motor should break, Balloon alarm buzzer installed acts as a safety device. It will sound during normal operation if the balloon attempts to make contact with the lamp’s hot! surface. If this condition occurs, immediately place the GloBug’s ON/OFF switch in the OFF position.
Expendable parts such as balloon envelope and lamp can be quickly replaced without any tools and with less effort. Adjusting angle of the balloon, that is to change the illumination area, and storing balloon are operated easily.
The fabric made of a special material is very resistant to heat. As the test results show below, the fabric does not melt with any temperature at each part.
As a material of the balloon envelope of GloBugTM series, the most suitable fabric, is well diffusive, durable and heatproof, is selected. Maintenance to the balloon envelope is possible, making it last for a long time.
Common dirt such as mud will come out in washing machines. Detach the envelope from the balloon and put it in a laundry bag. You can wash it readily with most neutral detergent. In the case of greasy dirt, wipe off the dirt using grease and oil cleaning sprays and wash it in a washing machines.
Heatproof of balloonHeat resistanttemperature
320 to 360°F
Meltingtemperature
500°F
0°F 100°F 400°F
Surfaceof lamp
Lamp guard
Internal airof balloon
Surface of lampInternal air of balloon
Lamp guard
Thermostat
1. Unzip the zipper at the bottom and top of the balloon.
2. Remove the balloon envelope and cover with a new one.
3. Zip up the zipper.
FEATURES OF BALLOON LIGHT
Lumens
12,000hr
400hr
8.3A33.5A
8.50USD
128.00USD
Life hours
Required amperages
Annual Cost
■ LARGE LIGHT SOURCE FOR HIGH VISIBLITYBalloon Light is safe for surrounding traffic as large light is highly visible and seen from afar. The light that forms less darker shadow is also comfortable for the workers.
■ LONG-LIVED HIGH EFFICIENCY LAMP
Comparison between Metal halide and Halogen
HEATPROOF
Metal halide lamp being used for GloBugTM is high efficiency, longer life and stronger to vibration compared with Halogen lamp.
■ MESSAGE STRIP FOR ATTENTION (OPTION)Since it has integral Velcoro strips, message strip can be quickly installed with no tools. Special occasion balloon are avalable or design your won
As most of balloon lights that adopt halogen use 1000W x 2 bulbs, some comparisons with metal halides are counted with 2 halogen bulbs.
Message Strips fit on both sides of the balloon.
*7 hours/day x 365days
104,500lm
52,000lm (26,000lm x 2) 200%200%approx.approx.
Higher Light OutputHigher Light Output
1/41/4approx.approx.
More Energy CoservationMore Energy Coservation
1/151/15approx.approx.
Lower Cost ReductionLower Cost Reduction
3000%3000% Longer LifeLonger Lifeapprox.approx.
Metal halide lampHalogen lamp
$8.50
$128.00
Higher Light Output
Longer Life
Better Energy Conservation
Lower Operating Cost
GloBug FeaturesGloBug Lighting System
Material of Balloon Envelope
Replacing
Washing
BALLOON ENVELOPE
The fan motor (blower) that inflates the balloon also acts as a cooling function. If the fan motor should break, Balloon alarm buzzer installed acts as a safety device. It will sound during normal operation if the balloon attempts to make contact with the lamp’s hot! surface. If this condition occurs, immediately place the GloBug’s ON/OFF switch in the OFF position.
Expendable parts such as balloon envelope and lamp can be quickly replaced without any tools and with less effort. Adjusting angle of the balloon, that is to change the illumination area, and storing balloon are operated easily.
The fabric made of a special material is very resistant to heat. As the test results show below, the fabric does not melt with any temperature at each part.
As a material of the balloon envelope of GloBugTM series, the most suitable fabric, is well diffusive, durable and heatproof, is selected. Maintenance to the balloon envelope is possible, making it last for a long time.
Common dirt such as mud will come out in washing machines. Detach the envelope from the balloon and put it in a laundry bag. You can wash it readily with most neutral detergent. In the case of greasy dirt, wipe off the dirt using grease and oil cleaning sprays and wash it in a washing machines.
Heatproof of balloonHeat resistanttemperature
320 to 360°F
Meltingtemperature
500°F
0°F 100°F 400°F
Surfaceof lamp
Lamp guard
Internal airof balloon
Surface of lampInternal air of balloon
Lamp guard
Thermostat
1. Unzip the zipper at the bottom and top of the balloon.
2. Remove the balloon envelope and cover with a new one.
3. Zip up the zipper.
FEATURES OF BALLOON LIGHT
Lumens
12,000hr
400hr
8.3A33.5A
8.50USD
128.00USD
Life hours
Required amperages
Annual Cost
■ LARGE LIGHT SOURCE FOR HIGH VISIBLITYBalloon Light is safe for surrounding traffic as large light is highly visible and seen from afar. The light that forms less darker shadow is also comfortable for the workers.
■ LONG-LIVED HIGH EFFICIENCY LAMP
Comparison between Metal halide and Halogen
HEATPROOF
Metal halide lamp being used for GloBugTM is high efficiency, longer life and stronger to vibration compared with Halogen lamp.
■ MESSAGE STRIP FOR ATTENTION (OPTION)Since it has integral Velcoro strips, message strip can be quickly installed with no tools. Special occasion balloon are avalable or design your won
As most of balloon lights that adopt halogen use 1000W x 2 bulbs, some comparisons with metal halides are counted with 2 halogen bulbs.
Message Strips fit on both sides of the balloon.
*7 hours/day x 365days
104,500lm
52,000lm (26,000lm x 2) 200%200%approx.approx.
Higher Light OutputHigher Light Output
1/41/4approx.approx.
More Energy CoservationMore Energy Coservation
1/151/15approx.approx.
Lower Cost ReductionLower Cost Reduction
3000%3000% Longer LifeLonger Lifeapprox.approx.
Metal halide lampHalogen lamp
Balloon MaterialThe GloBug ballons are fabricated from material that is durable, heat resistant, and easy to maintain.
The fan motor (blower) that inflates the balloon also provides a cooling function. Should the fan motor stop working, an audible alarm alerts the crew to the problem.
Heatproof Balloon — The heat resistant fabric will not melt, should it come into contact with any part of the light fixture.
GloBug Lighting SystemGloBug Lighting System
Material of Balloon Envelope
Replacing
Washing
BALLOON ENVELOPE
The fan motor (blower) that inflates the balloon also acts as a cooling function. If the fan motor shouldbreak, BALLOON ALARM BUZZER installed acts as a safety device. It will sound during normal operationif the balloon attempts to make contact with the lamp’s hot! surface. If this condition occurs, immediatelyplace the GloBug’s ON/OFF switch in the OFF position.
Expendable parts such as balloon envelope and lamp can be quickly replaced without any tools and withless effort. Adjusting angle of the balloon, that is to change the illumination area, and storing balloon areoperated easily.
The fabric made of a special material is very resistant to heat. As the test results show below, the fabricdoes not melt with any temperature at each part.
As a material of the balloon envelope of GloBugTM series, the most suitable fabric, is well diffusive, durableand heatproof, is selected. Maintenance to the balloon envelope is possible, making it last for a long time.
Common dirt such as mud will come out in washing machines. Detach the envelope from the balloon andput it in a laundry bag. You can wash it readily with most neutral detergent. In the case of greasy dirt, wipeoff the dirt using grease and oil cleaning sprays and wash it in a washing machines.
Heatproof of balloonHeat resistanttemperature
320 to 360°F
Meltingtemperature
500°F
0°F 100°F 400°F
Surfaceof lamp
Lamp guard
Internal airof balloon
Surface of lampInternal air
of balloon
Lamp guard
Thermostat
1. Unzip the zipper at the bottomand top of the balloon.
2. Remove the balloon envelopeand cover with a new one.
3. Zip up the zipper.
HEATPROOF
with Traditional Light Tower
with Balloon light competitor
COMPARISON
Compared to traditional 1000W x 4 class of light tower (Spotlight type), GloBugTM series can illuminate a largearea with more homogeneous light, even though the required power is the quarter at only 1000W. You canilluminate with safer and non-glare light at low cost since GloBugTM series eats much less fuel than 4000Wclass of light towers do. The followings is a comparison between Traditional light tower & GloBugTM "Cart type -GB114BC".
Compared to competitors's balloon lighting system such as Ingersoll Rand Balloon Light "BL2000" the light ofGloBugTM series reaches further. For example, when BL2000 illuminates 15,000 sqft., GloBugTM “Cart type -GB114BC" can illuminate 30,000 spft. with the same brightness.
COVERRAGE RANGE
GB114BCDrum Shaped Balloon
Traditinal light tower1000W x 4 lamps
GB114BCStandard Balloon
GB114BCReflector Balloon
Distance from Light Souce
Illum
inat
ion
(Foo
t-can
dle)
15 feet
9.0
17.8
22.2
26.9
30 feet
2.86.6 7.56.7
45 feet
1.42.9 3.22.7
60 feet
0.91.7 1.91.5MQ"G
loBu
g"wi
thDr
umSh
aped
Ballo
onMQ
"Glo
Bug"
with
Regl
ecto
rBall
oon
MQ"G
loBu
g"wi
thSt
anda
rdBa
lloon
IR"B
L200
0"
3 feet
22.3
36.4
54.8
94.8
The fan motor (blower) that inflates the balloon also provides a cooling function. Should the fan motor stop working, an audible alarm alerts the crew to the problem.
Washing — The balloon is easily removed by unzipping it from the base. It can be hand washed or machine washed, in a laundry bag with a neurtral detergent. Grease or oil stains should can be cleaned with cleaning sprays.
Replacement Balloons — Should the balloon require replacement it can be done quickly and without any tools. Balloons can be easily removed for storage; an integral protective cover is provided.
Balloon MaterialThe GloBug ballons are fabricated from material that is durable, heat resistant, and easy to maintain.
Heatproof Balloon — The heat resistant fabric is tested to make sure it does not melt, should it come into contact with any part of the light fixture.
Heatproof Balloon
Heat resistant temperature 320 to 360°F
Melting temperature
500°F
Surface of lamp
Lamp guard
Air inside balloon
0°F 100°F 400°F
1. Unzip the zipper at the bottom and top of the balloon.
2. Remove the balloon envelope and cover with a new one.
3. Zip up the zipper.
Surface of lampInternal air of balloon
Lamp guard
Thermostat
Surface of lampInternal air of balloon
Lamp guard
Old Image
New Image
Please replace the image as below.
GloBug Lighting System
Material of Balloon Envelope
Replacing
Washing
BALLOON ENVELOPE
The fan motor (blower) that inflates the balloon also acts as a cooling function. If the fan motor should break, Balloon alarm buzzer installed acts as a safety device. It will sound during normal operation if the balloon attempts to make contact with the lamp’s hot! surface. If this condition occurs, immediately place the GloBug’s ON/OFF switch in the OFF position.
Expendable parts such as balloon envelope and lamp can be quickly replaced without any tools and with less effort. Adjusting angle of the balloon, that is to change the illumination area, and storing balloon are operated easily.
The fabric made of a special material is very resistant to heat. As the test results show below, the fabric does not melt with any temperature at each part.
As a material of the balloon envelope of GloBugTM series, the most suitable fabric, is well diffusive, durable and heatproof, is selected. Maintenance to the balloon envelope is possible, making it last for a long time.
Common dirt such as mud will come out in washing machines. Detach the envelope from the balloon and put it in a laundry bag. You can wash it readily with most neutral detergent. In the case of greasy dirt, wipe off the dirt using grease and oil cleaning sprays and wash it in a washing machines.
Heatproof of balloonHeat resistanttemperature
320 to 360°F
Meltingtemperature
500°F
0°F 100°F 400°F
Surfaceof lamp
Lamp guard
Internal airof balloon
Surface of lampInternal air of balloon
Lamp guard
Thermostat
1. Unzip the zipper at the bottom and top of the balloon.
2. Remove the balloon envelope and cover with a new one.
3. Zip up the zipper.
FEATURES OF BALLOON LIGHT
Lumens
12,000hr
400hr
8.3A33.5A
8.50USD
128.00USD
Life hours
Required amperages
Annual Cost
■ LARGE LIGHT SOURCE FOR HIGH VISIBLITYBalloon Light is safe for surrounding traffic as large light is highly visible and seen from afar. The light that forms less darker shadow is also comfortable for the workers.
■ LONG-LIVED HIGH EFFICIENCY LAMP
Comparison between Metal halide and Halogen
HEATPROOF
Metal halide lamp being used for GloBugTM is high efficiency, longer life and stronger to vibration compared with Halogen lamp.
■ MESSAGE STRIP FOR ATTENTION (OPTION)Since it has integral Velcoro strips, message strip can be quickly installed with no tools. Special occasion balloon are avalable or design your won
As most of balloon lights that adopt halogen use 1000W x 2 bulbs, some comparisons with metal halides are counted with 2 halogen bulbs.
Message Strips fit on both sides of the balloon.
*7 hours/day x 365days
104,500lm
52,000lm (26,000lm x 2) 200%200%approx.approx.
Higher Light OutputHigher Light Output
1/41/4approx.approx.
More Energy CoservationMore Energy Coservation
1/151/15approx.approx.
Lower Cost ReductionLower Cost Reduction
3000%3000% Longer LifeLonger Lifeapprox.approx.
Metal halide lampHalogen lamp
GloBug Lighting System
Material of Balloon Envelope
Replacing
Washing
BALLOON ENVELOPE
The fan motor (blower) that inflates the balloon also acts as a cooling function. If the fan motor should break, Balloon alarm buzzer installed acts as a safety device. It will sound during normal operation if the balloon attempts to make contact with the lamp’s hot! surface. If this condition occurs, immediately place the GloBug’s ON/OFF switch in the OFF position.
Expendable parts such as balloon envelope and lamp can be quickly replaced without any tools and with less effort. Adjusting angle of the balloon, that is to change the illumination area, and storing balloon are operated easily.
The fabric made of a special material is very resistant to heat. As the test results show below, the fabric does not melt with any temperature at each part.
As a material of the balloon envelope of GloBugTM series, the most suitable fabric, is well diffusive, durable and heatproof, is selected. Maintenance to the balloon envelope is possible, making it last for a long time.
Common dirt such as mud will come out in washing machines. Detach the envelope from the balloon and put it in a laundry bag. You can wash it readily with most neutral detergent. In the case of greasy dirt, wipe off the dirt using grease and oil cleaning sprays and wash it in a washing machines.
Heatproof of balloonHeat resistanttemperature
320 to 360°F
Meltingtemperature
500°F
0°F 100°F 400°F
Surfaceof lamp
Lamp guard
Internal airof balloon
Surface of lampInternal air of balloon
Lamp guard
Thermostat
1. Unzip the zipper at the bottom and top of the balloon.
2. Remove the balloon envelope and cover with a new one.
3. Zip up the zipper.
FEATURES OF BALLOON LIGHT
Lumens
12,000hr
400hr
8.3A33.5A
8.50USD
128.00USD
Life hours
Required amperages
Annual Cost
■ LARGE LIGHT SOURCE FOR HIGH VISIBLITYBalloon Light is safe for surrounding traffic as large light is highly visible and seen from afar. The light that forms less darker shadow is also comfortable for the workers.
■ LONG-LIVED HIGH EFFICIENCY LAMP
Comparison between Metal halide and Halogen
HEATPROOF
Metal halide lamp being used for GloBugTM is high efficiency, longer life and stronger to vibration compared with Halogen lamp.
■ MESSAGE STRIP FOR ATTENTION (OPTION)Since it has integral Velcoro strips, message strip can be quickly installed with no tools. Special occasion balloon are avalable or design your won
As most of balloon lights that adopt halogen use 1000W x 2 bulbs, some comparisons with metal halides are counted with 2 halogen bulbs.
Message Strips fit on both sides of the balloon.
*7 hours/day x 365days
104,500lm
52,000lm (26,000lm x 2) 200%200%approx.approx.
Higher Light OutputHigher Light Output
1/41/4approx.approx.
More Energy CoservationMore Energy Coservation
1/151/15approx.approx.
Lower Cost ReductionLower Cost Reduction
3000%3000% Longer LifeLonger Lifeapprox.approx.
Metal halide lampHalogen lamp
Washing — The balloon is easily re moved by unzipping it from the base. It can be hand washed or machine washed, in a laundry bag with a neurtral detergent. Grease or oil stains should can be cleaned with cleaning sprays.
Replacement Balloons — Should the balloon require replacement it can be done quickly and without any tools. Balloons can be easily removed for storage; an integral protective cover is provided.
Comparision to Conventional Light TowersCompared to conventional light towers (4x1000 Watt bulbs), the GloBug illuminates a large area while using 75% less power. The following is a comparison between a conventional light tower and the GB114BC.
■ GLARE-FREE LIGHTING FOR TRAFIC SAFETY
Features of Balloon Light
Spot ligh Balloon Light Coverage Range of GB113BC
Spot Light Balloon Light
GloBugTM Lighting System gives enough light to a work area but eyes are never blinded by glare even if seeing the light directly. It is gentle to surrounding traffic.
■ WIDE COVERAGE RANGE WITH HOMOGENEOUS LIGHTINGCompared to Traditional Spotlight towers that concentrate the light to a fixed direction, GloBugTM series can radiate the homogeneous light far and wide from the balloon to all directions.
■ 360°ILLUMINATION WITHOUT BLIND SPOTComing from the whole balloon, the light reaches over 360 degrees and to a long distance homogeneously. Illuminating fixed direction or close to residential area, you can use a reflector balloon.
Facing back light, you cannot see conditions of the road behind the light.
As the balloon illuminates the whole area of the site, you can see conditions beyond the site. So it is safe.
Unit: footcandle, 1 grid: 50ft.
with Traditional Light Tower
with Balloon light competitor
Compared to traditional 1000W x 4 class of light tower (Spotlight type), GloBugTM series can illuminate a large area with more homogeneous light, even though the required power is the quarter at only 1000W. You can illuminate with safer and non-glare light at low cost since GloBugTM series eats much less fuel than 4000W class of light towers do. The followings is a comparison between Traditional light tower & GloBugTM "Cart type - GB114BC".
Compared to competitors's balloon lighting system such as Ingersoll Rand Balloon Light "BL2000" the light of GloBugTM series reaches further. For example, when BL2000 illuminates 15,000 sqft., GloBugTM “Cart type - GB114BC" can illuminate 30,000 spft. with the same brightness.
COVERRAGE RANGE
GB114BCDrum Shaped Balloon
Traditinal light tower1000W x 4 lamps
GB114BCStandard Balloon
GB114BCReflector Balloon
Distance from Light Souce
Illum
inat
ion
(Foo
t-can
dle)
15 feet
9.0
17.8
22.2
26.9
30 feet
2.86.6 7.56.7
45 feet
1.42.9 3.22.7
60 feet
0.91.7 1.91.5MQ "G
loBu
g" w
ith D
rum
Sha
ped
Ballo
onMQ
"Glo
Bug"
with
Reg
lecto
r Ball
oon
MQ "G
loBu
g" w
ith S
tand
ard
Ballo
on
IR "B
L200
0"
3 feet
22.3
36.4
54.8
94.8
GloBug Lighting System COMPARISON
Traditional Light Tower 1000W x 4 Lamps
GB114BC Standard Balloon
GB114BC Reflector Balloon
GB114BC Drum-Shaped Balloon
Comparison to Other Balloon DesignsCompared to the Ingersol l -Rand BL2000, the GloBug illuminates a much larger area. For example, the BL2000 illuminates 15,000 ft² while the GloBug GB114BC illuminates 30,000 ft² at the same brightness.
Illum
inat
ion
(foot
-can
dles
)
3 feet 15 feet 30 feet 45 feet 60 feet
■ GLARE-FREE LIGHTING FOR TRAFIC SAFETY
Features of Balloon Light
Spot ligh Balloon Light Coverage Range of GB113BC
Spot Light Balloon Light
GloBugTM Lighting System gives enough light to a work area but eyes are never blinded by glare even if seeing the light directly. It is gentle to surrounding traffic.
■ WIDE COVERAGE RANGE WITH HOMOGENEOUS LIGHTINGCompared to Traditional Spotlight towers that concentrate the light to a fixed direction, GloBugTM series can radiate the homogeneous light far and wide from the balloon to all directions.
■ 360°ILLUMINATION WITHOUT BLIND SPOTComing from the whole balloon, the light reaches over 360 degrees and to a long distance homogeneously. Illuminating fixed direction or close to residential area, you can use a reflector balloon.
Facing back light, you cannot see conditions of the road behind the light.
As the balloon illuminates the whole area of the site, you can see conditions beyond the site. So it is safe.
Unit: footcandle, 1 grid: 50ft.
with Traditional Light Tower
with Balloon light competitor
Compared to traditional 1000W x 4 class of light tower (Spotlight type), GloBugTM series can illuminate a large area with more homogeneous light, even though the required power is the quarter at only 1000W. You can illuminate with safer and non-glare light at low cost since GloBugTM series eats much less fuel than 4000W class of light towers do. The followings is a comparison between Traditional light tower & GloBugTM "Cart type - GB114BC".
Compared to competitors's balloon lighting system such as Ingersoll Rand Balloon Light "BL2000" the light of GloBugTM series reaches further. For example, when BL2000 illuminates 15,000 sqft., GloBugTM “Cart type - GB114BC" can illuminate 30,000 spft. with the same brightness.
COVERRAGE RANGE
GB114BCDrum Shaped Balloon
Traditinal light tower1000W x 4 lamps
GB114BCStandard Balloon
GB114BCReflector Balloon
Distance from Light Souce
Illum
inat
ion
(Foo
t-can
dle)
15 feet
9.0
17.8
22.2
26.9
30 feet
2.86.6 7.56.7
45 feet
1.42.9 3.22.7
60 feet
0.91.7 1.91.5MQ "G
loBu
g" w
ith D
rum
Sha
ped
Ballo
onMQ
"Glo
Bug"
with
Reg
lecto
r Ball
oon
MQ "G
loBu
g" w
ith S
tand
ard
Ballo
on
IR "B
L200
0"
3 feet
22.3
36.4
54.8
94.8
GloBug Lighting System COMPARISON
MQ
Glo
Bug
with
Sta
ndar
d B
allo
on
MQ
Glo
Bug
with
Refl
ecto
r Bal
loon
MQ
Glo
Bug
with
Dru
m-S
hape
d B
allo
on
Heatproof Balloon
Melting temperature
500°F
Surface of lamp
Lamp guard
Air inside balloon
0°F 100°F 400°F
Heat resistant temperature 320 to 360°F
© C
OP
YR
IGH
T 2008, M
ULT
IQU
IP IN
C.
All features and specifications are subject to change without notice.MQGLOBUG-683 Rev. D (04-08)
MULTIQUIP INC.POST OFFICE BOX 6254CARSON, CA 90749310-537-3700 • 800-421-1244FAX: 310-537-3927E-MAIL: [email protected]
Your Multiquip dealer is:
Multiquip’s GloBug. You’ve seen the light.Light Output ChartsBal 115D — Drum Balloon (with Velcro Strips) Bal 120 — Standard Balloon Bal 120R — Reflector Balloon
Footcandles FeetBAL120 BAL120R BAL115D
10 24 27 27
5 34 34 36
2 55 52 57
1 79 71 82
0.5 107 96 110
0.25 135 118 168
50 ft. 50 ft. 50 ft.
GB-114BC GloBug GB-114BW GloBug Solo
Voltage 120V 120V
Amps 9.5 9.5
Lamp Type 1,000 watt Metal Halide (x1) 1,000 watt Metal Halide (x1)
Total luminous flux 112,000 lm 112,000 lm
Standard Balloon Diameter in. (mm) 47 (1200) 47 (1200)
Mast — Number of stages 4 3
Winch type Manual Gas shock absorbers
Dimensions LxWxH in. (mm) — Working
58 x 57 x 90 to 197 (1460x1450x2250 to 4980)
80 x 80 x 80 to 157 (203 x 203 x 203 to 399)
Dimensions LxWxH in. (mm) — Storage
41 x 32 x 66 (1040 x 800 x 1655)
25 x 25 x 72 (64 x 64 x 182)
Weight lb. (kg) 243 (110) 139 (63)
Ordering information
GB114BC — GloBug with cart (generator optional); includes BAL-120 Balloon
GB114BW — GloBug Solo (with stand); includes BAL-120 Balloon
BAL-115D — Drum Shaped Balloon with integral Velcro strips to hold BALD1 Message Strips
BALD1 — Blank Message Strip (11½" x 42") for BAL-115D (Two required per balloon)
Available Balloons:
BAL-120 — Standard
BAL-120R — Reflector
Optional special occasion balloons are available — or design your own. Call for details and pricing.
Specifications
Message Strips fit on both sides of the balloon!