GloBug Light Towers · power cable Three-stage mast ... point lifting without removing attachments....

8
www.multiquip.com Construction Starts Here See the light. GloBug Light Towers

Transcript of GloBug Light Towers · power cable Three-stage mast ... point lifting without removing attachments....

Page 1: GloBug Light Towers · power cable Three-stage mast ... point lifting without removing attachments. ... The fabric made of a special materi al is very resistant to5 heat.

www.multiquip.comConstruction Starts Here

See the light.

GloBug Light Towers™

You've seen the light.

Your Multiquip dealer is:

All features and specifications are subject to change without notice.GLOBUG-405 (04-06) www.multiquip.com

see the light.

GB114BC

Looking in the light's direction during at night-time, you may be dazzled and blinded for a while. Balloon lighting of GloBugTM series gives enough light to the work site but no unplesantness to the surrounding traffic.

MULTIQUIP INC.POST OFFICE BOX 6254CARSON, CA 90749310-537-3700 900-421-1244FAX: 310-537-3927E-MAIL: [email protected]

Page 2: GloBug Light Towers · power cable Three-stage mast ... point lifting without removing attachments. ... The fabric made of a special materi al is very resistant to5 heat.

GloBug Lighting System

GlowBug Solo is easily transportable; protective canvas balloon cover is included as standard.

Quick disconnect power cable

Three-stage mast with extension pole

Gas shock absorbers for easy lifting

Caster wheels with stoppers

Lifting hook

Locking latch — locks mast at desired height

Removable ballast box

Five outriggers for stabilization

Counterweights lock outriggers into place

Extra 30" extension pole

360° glare-free lighting

Up to 13' 1" tall

GloBug SoloWhen space is limited but illumination is required, call on the Multiquip GloBug Solo GB-114BW

Protective canvas cover stores balloon while not in use.

n Metal Halide lamp — single 1,000 watt lamp for maximum illumination. Pure white light — 3400° K.

n 360° glarefree illumination with standard balloon (BAL120).

n Stainless steel construction.

n Downward direct illumination with reflector balloon.

n Self-inflating balloons are easy to install and inflate in less than 20 seconds.

n Three-stage mast with extension pole — extends up to 13' 1".

n Caster wheels with stoppers for easy maneuverability.

n Five outriggers for great stabilization.

n Light coverage up to 150 feet.

Stainless steel construction for long life and easy maintenance

Page 3: GloBug Light Towers · power cable Three-stage mast ... point lifting without removing attachments. ... The fabric made of a special materi al is very resistant to5 heat.

EFFICIENT DESIGNThe light is easily moved as construction progresses to provide a safe work environment for workers.

SAFE FOR VEHICLE TRAFFICDrivers are not blinded by the intense glare of conventional light towers, helping improve roadway safety.

SAFE FOR CONSTRUCTION CREWSThe glare-free lighting benefits work crews by improving visibility and eliminating blind spots.

Equipment-Mount GB114BS

EASY SET UPGas-assisted mast allows the balloon to be raised with minimal effort. A counterweight locks the outrigger into place automatically.

EASY HANDLINGThe work stand has five caster wheels for easy maneuverability. The well balanced design allows single point lifting without removing attachments.

SAFE DESIGNFive outriggers provide excellent stabilization. The gas-assisted mast prevents it from coming down unexpectedly when raising or lowering.

Easy lifting with Gas-assisted mast

Five outriggers for excellent stabilization; five caster wheels for smooth transit.

GloBug Solo GB114BW

Flexible Clamps allow installation at any angle

Page 4: GloBug Light Towers · power cable Three-stage mast ... point lifting without removing attachments. ... The fabric made of a special materi al is very resistant to5 heat.

GloBug Lighting SystemCart Type GB114BC

DESIGNED FOR CONSTRUCTION APPLICATIONSThe balloon, mast and cart are all designed to withstand the rigors of the jobsite.

Impact-Resistant FrameVibration-Proof Lamp

Durable, Heatproof and Washable Fabric

EXCELLENT MANEUVERABILITYPneumatic tires and a T-bar steering handle allow easily handling on the jobsite.

Parking BrakeSteering Handle

Brake Pedal Brake Pad

EASY TRANSPORTATIONOne truck can transport several GloBugs for reduced transportation costs.

4 units of GB114BC can be transported by a 6' x 8' trailer

EXCELLENT WIND STABILITYGloBug’s unqique “One-Touch Outriggers” are quickly set and automatically lock into place. No special handling is required.

GB114BC GB114BW Wind Tunnel test

Unit shown with optional generator.

Page 5: GloBug Light Towers · power cable Three-stage mast ... point lifting without removing attachments. ... The fabric made of a special materi al is very resistant to5 heat.

Shown with optional generator

Quick-disconnect power cable

Reflector maximizes downlighting (BAL-120R balloon only)

Protective canvas cover stores balloon while not in use

Optional drum-shaped balloon with Velcro strips to hold warning or promotional messages — installs quickly with no tools

360° glare-free lighting

Four-stage mastTilting grip handle

Lifting hook for easy transportSafety winch prevents mast from

collapsing

Handle bar for easy transportation

Counterweights lock outriggers into place

Parking brake

Internal ballast for safety

Pneumatic tires for easy maneuverability

Outriggers for stabilization (shown in their undeployed state)

Optional generator

Multiquip’s GB-114BC GloBug Lighting System is designed to provide glare-free lighting for a wide range of applications.

n Metal Halide lamp — one 1,000 watt lamp for maximum illumination.

n 360° glare-free illumination with standard balloon (BAL-120).

n Downward direct illumination with reflector balloon.

n Self-inflating balloons are easy to install and change; inflate in less than 20 seconds.

n Four-stage mast extends to 16.5 feet.

n Steerable cart.

Use GloBug Solo on these and other applications:n Disaster reliefn Night parkingn Emergency repairsn Landscapingn Farming and agriculture ...and many more

n Road constructionn Search and rescuen Special eventsn Parking lot lightingn Partiesn Maintenancen Mining

Stainless steel construction for long life and easy maintenance

Page 6: GloBug Light Towers · power cable Three-stage mast ... point lifting without removing attachments. ... The fabric made of a special materi al is very resistant to5 heat.

GloBug Lighting System

Material of Balloon Envelope

Replacing

Washing

BALLOON ENVELOPE

The fan motor (blower) that inflates the balloon also acts as a cooling function. If the fan motor should break, Balloon alarm buzzer installed acts as a safety device. It will sound during normal operation if the balloon attempts to make contact with the lamp’s hot! surface. If this condition occurs, immediately place the GloBug’s ON/OFF switch in the OFF position.

Expendable parts such as balloon envelope and lamp can be quickly replaced without any tools and with less effort. Adjusting angle of the balloon, that is to change the illumination area, and storing balloon are operated easily.

The fabric made of a special material is very resistant to heat. As the test results show below, the fabric does not melt with any temperature at each part.

As a material of the balloon envelope of GloBugTM series, the most suitable fabric, is well diffusive, durable and heatproof, is selected. Maintenance to the balloon envelope is possible, making it last for a long time.

Common dirt such as mud will come out in washing machines. Detach the envelope from the balloon and put it in a laundry bag. You can wash it readily with most neutral detergent. In the case of greasy dirt, wipe off the dirt using grease and oil cleaning sprays and wash it in a washing machines.

Heatproof of balloonHeat resistanttemperature

320 to 360°F

Meltingtemperature

500°F

0°F 100°F 400°F

Surfaceof lamp

Lamp guard

Internal airof balloon

Surface of lampInternal air of balloon

Lamp guard

Thermostat

1. Unzip the zipper at the bottom and top of the balloon.

2. Remove the balloon envelope and cover with a new one.

3. Zip up the zipper.

FEATURES OF BALLOON LIGHT

Lumens

12,000hr

400hr

8.3A33.5A

8.50USD

128.00USD

Life hours

Required amperages

Annual Cost

■ LARGE LIGHT SOURCE FOR HIGH VISIBLITYBalloon Light is safe for surrounding traffic as large light is highly visible and seen from afar. The light that forms less darker shadow is also comfortable for the workers.

■ LONG-LIVED HIGH EFFICIENCY LAMP

Comparison between Metal halide and Halogen

HEATPROOF

Metal halide lamp being used for GloBugTM is high efficiency, longer life and stronger to vibration compared with Halogen lamp.

■ MESSAGE STRIP FOR ATTENTION (OPTION)Since it has integral Velcoro strips, message strip can be quickly installed with no tools. Special occasion balloon are avalable or design your won

As most of balloon lights that adopt halogen use 1000W x 2 bulbs, some comparisons with metal halides are counted with 2 halogen bulbs.

Message Strips fit on both sides of the balloon.

*7 hours/day x 365days

104,500lm

52,000lm (26,000lm x 2) 200%200%approx.approx.

Higher Light OutputHigher Light Output

1/41/4approx.approx.

More Energy CoservationMore Energy Coservation

1/151/15approx.approx.

Lower Cost ReductionLower Cost Reduction

3000%3000% Longer LifeLonger Lifeapprox.approx.

Metal halide lampHalogen lamp

GloBug Lighting System

Material of Balloon Envelope

Replacing

Washing

BALLOON ENVELOPE

The fan motor (blower) that inflates the balloon also acts as a cooling function. If the fan motor should break, Balloon alarm buzzer installed acts as a safety device. It will sound during normal operation if the balloon attempts to make contact with the lamp’s hot! surface. If this condition occurs, immediately place the GloBug’s ON/OFF switch in the OFF position.

Expendable parts such as balloon envelope and lamp can be quickly replaced without any tools and with less effort. Adjusting angle of the balloon, that is to change the illumination area, and storing balloon are operated easily.

The fabric made of a special material is very resistant to heat. As the test results show below, the fabric does not melt with any temperature at each part.

As a material of the balloon envelope of GloBugTM series, the most suitable fabric, is well diffusive, durable and heatproof, is selected. Maintenance to the balloon envelope is possible, making it last for a long time.

Common dirt such as mud will come out in washing machines. Detach the envelope from the balloon and put it in a laundry bag. You can wash it readily with most neutral detergent. In the case of greasy dirt, wipe off the dirt using grease and oil cleaning sprays and wash it in a washing machines.

Heatproof of balloonHeat resistanttemperature

320 to 360°F

Meltingtemperature

500°F

0°F 100°F 400°F

Surfaceof lamp

Lamp guard

Internal airof balloon

Surface of lampInternal air of balloon

Lamp guard

Thermostat

1. Unzip the zipper at the bottom and top of the balloon.

2. Remove the balloon envelope and cover with a new one.

3. Zip up the zipper.

FEATURES OF BALLOON LIGHT

Lumens

12,000hr

400hr

8.3A33.5A

8.50USD

128.00USD

Life hours

Required amperages

Annual Cost

■ LARGE LIGHT SOURCE FOR HIGH VISIBLITYBalloon Light is safe for surrounding traffic as large light is highly visible and seen from afar. The light that forms less darker shadow is also comfortable for the workers.

■ LONG-LIVED HIGH EFFICIENCY LAMP

Comparison between Metal halide and Halogen

HEATPROOF

Metal halide lamp being used for GloBugTM is high efficiency, longer life and stronger to vibration compared with Halogen lamp.

■ MESSAGE STRIP FOR ATTENTION (OPTION)Since it has integral Velcoro strips, message strip can be quickly installed with no tools. Special occasion balloon are avalable or design your won

As most of balloon lights that adopt halogen use 1000W x 2 bulbs, some comparisons with metal halides are counted with 2 halogen bulbs.

Message Strips fit on both sides of the balloon.

*7 hours/day x 365days

104,500lm

52,000lm (26,000lm x 2) 200%200%approx.approx.

Higher Light OutputHigher Light Output

1/41/4approx.approx.

More Energy CoservationMore Energy Coservation

1/151/15approx.approx.

Lower Cost ReductionLower Cost Reduction

3000%3000% Longer LifeLonger Lifeapprox.approx.

Metal halide lampHalogen lamp

GloBug Lighting System

Spot Light Balloon Light

Spot Light — Worksite visibility is reduced due to the intense glare.

Balloon Light — The balloon illuminates the entire site; workers can see clearly beyond the site for improved safety.

EXCELLENT VISIBILITYThe balloon is highly visible when the mast is fully extended, improving safety. Its unique design reduces shadows in the work area.

HIGH QUALITY LAMPMetal halide lamps offer high efficiency with longer life and better vibration resistance compared to halogen lamps.

Comparison of metal halide vs. halogen lamps

Note: Manufacturers using halogen lamps typically use two 1000 watt bulbs

Lumens

Life (hours)

Required amperage

Annual Cost

MESSAGE STRIPSCustom messages are easily applied using Velcro® fasteners. Special occasion balloons are also available.

BLIND SPOT-FREE WORK AREA Light output from the balloon radiates a full 360 degrees without a blind spot. Special balloons are available for work in confined spaces or in residential areas.

GLARE-FREE LIGHTING FOR TRAFFFIC SAFETYGloBug lighting systems offer superior illumin ation for construction crews along highways. Motorists are not subjected to the intense glare produced by conventional light towers — even when looking directly at the light.

WIDE COVERAGE AREAConventional light towers concentrate light in a fixed direction. GloBug radiates its light evenly all the way around the balloon.

■ GLARE-FREE LIGHTING FOR TRAFIC SAFETY

Features of Balloon Light

Spot ligh Balloon Light Coverage Range of GB113BC

Spot Light Balloon Light

GloBugTM Lighting System gives enough light to a work area but eyes are never blinded by glare even if seeing the light directly. It is gentle to surrounding traffic.

■ WIDE COVERAGE RANGE WITH HOMOGENEOUS LIGHTINGCompared to Traditional Spotlight towers that concentrate the light to a fixed direction, GloBugTM series can radiate the homogeneous light far and wide from the balloon to all directions.

■ 360°ILLUMINATION WITHOUT BLIND SPOTComing from the whole balloon, the light reaches over 360 degrees and to a long distance homogeneously. Illuminating fixed direction or close to residential area, you can use a reflector balloon.

Facing back light, you cannot see conditions of the road behind the light.

As the balloon illuminates the whole area of the site, you can see conditions beyond the site. So it is safe.

Unit: footcandle, 1 grid: 50ft.

with Traditional Light Tower

with Balloon light competitor

Compared to traditional 1000W x 4 class of light tower (Spotlight type), GloBugTM series can illuminate a large area with more homogeneous light, even though the required power is the quarter at only 1000W. You can illuminate with safer and non-glare light at low cost since GloBugTM series eats much less fuel than 4000W class of light towers do. The followings is a comparison between Traditional light tower & GloBugTM "Cart type - GB114BC".

Compared to competitors's balloon lighting system such as Ingersoll Rand Balloon Light "BL2000" the light of GloBugTM series reaches further. For example, when BL2000 illuminates 15,000 sqft., GloBugTM “Cart type - GB114BC" can illuminate 30,000 spft. with the same brightness.

COVERRAGE RANGE

GB114BCDrum Shaped Balloon

Traditinal light tower1000W x 4 lamps

GB114BCStandard Balloon

GB114BCReflector Balloon

Distance from Light Souce

Illum

inat

ion

(Foo

t-can

dle)

15 feet

9.0

17.8

22.2

26.9

30 feet

2.86.6 7.56.7

45 feet

1.42.9 3.22.7

60 feet

0.91.7 1.91.5MQ "G

loBu

g" w

ith D

rum

Sha

ped

Ballo

onMQ

"Glo

Bug"

with

Reg

lecto

r Ball

oon

MQ "G

loBu

g" w

ith S

tand

ard

Ballo

on

IR "B

L200

0"

3 feet

22.3

36.4

54.8

94.8

GloBug Lighting System COMPARISON

■ GLARE-FREE LIGHTING FOR TRAFIC SAFETY

Features of Balloon Light

Spot ligh Balloon Light Coverage Range of GB113BC

Spot Light Balloon Light

GloBugTM Lighting System gives enough light to a work area but eyes are never blinded by glare even if seeing the light directly. It is gentle to surrounding traffic.

■ WIDE COVERAGE RANGE WITH HOMOGENEOUS LIGHTINGCompared to Traditional Spotlight towers that concentrate the light to a fixed direction, GloBugTM series can radiate the homogeneous light far and wide from the balloon to all directions.

■ 360°ILLUMINATION WITHOUT BLIND SPOTComing from the whole balloon, the light reaches over 360 degrees and to a long distance homogeneously. Illuminating fixed direction or close to residential area, you can use a reflector balloon.

Facing back light, you cannot see conditions of the road behind the light.

As the balloon illuminates the whole area of the site, you can see conditions beyond the site. So it is safe.

Unit: footcandle, 1 grid: 50ft.

with Traditional Light Tower

with Balloon light competitor

Compared to traditional 1000W x 4 class of light tower (Spotlight type), GloBugTM series can illuminate a large area with more homogeneous light, even though the required power is the quarter at only 1000W. You can illuminate with safer and non-glare light at low cost since GloBugTM series eats much less fuel than 4000W class of light towers do. The followings is a comparison between Traditional light tower & GloBugTM "Cart type - GB114BC".

Compared to competitors's balloon lighting system such as Ingersoll Rand Balloon Light "BL2000" the light of GloBugTM series reaches further. For example, when BL2000 illuminates 15,000 sqft., GloBugTM “Cart type - GB114BC" can illuminate 30,000 spft. with the same brightness.

COVERRAGE RANGE

GB114BCDrum Shaped Balloon

Traditinal light tower1000W x 4 lamps

GB114BCStandard Balloon

GB114BCReflector Balloon

Distance from Light Souce

Illum

inat

ion

(Foo

t-can

dle)

15 feet

9.0

17.8

22.2

26.9

30 feet

2.86.6 7.56.7

45 feet

1.42.9 3.22.7

60 feet

0.91.7 1.91.5MQ "G

loBu

g" w

ith D

rum

Sha

ped

Ballo

onMQ

"Glo

Bug"

with

Reg

lecto

r Ball

oon

MQ "G

loBu

g" w

ith S

tand

ard

Ballo

on

IR "B

L200

0"

3 feet

22.3

36.4

54.8

94.8

GloBug Lighting System COMPARISON■ GLARE-FREE LIGHTING FOR TRAFIC SAFETY

Features of Balloon Light

Spot ligh Balloon Light Coverage Range of GB113BC

Spot Light Balloon Light

GloBugTM Lighting System gives enough light to a work area but eyes are never blinded by glare even if seeing the light directly. It is gentle to surrounding traffic.

■ WIDE COVERAGE RANGE WITH HOMOGENEOUS LIGHTINGCompared to Traditional Spotlight towers that concentrate the light to a fixed direction, GloBugTM series can radiate the homogeneous light far and wide from the balloon to all directions.

■ 360°ILLUMINATION WITHOUT BLIND SPOTComing from the whole balloon, the light reaches over 360 degrees and to a long distance homogeneously. Illuminating fixed direction or close to residential area, you can use a reflector balloon.

Facing back light, you cannot see conditions of the road behind the light.

As the balloon illuminates the whole area of the site, you can see conditions beyond the site. So it is safe.

Unit: footcandle, 1 grid: 50ft.

with Traditional Light Tower

with Balloon light competitor

Compared to traditional 1000W x 4 class of light tower (Spotlight type), GloBugTM series can illuminate a large area with more homogeneous light, even though the required power is the quarter at only 1000W. You can illuminate with safer and non-glare light at low cost since GloBugTM series eats much less fuel than 4000W class of light towers do. The followings is a comparison between Traditional light tower & GloBugTM "Cart type - GB114BC".

Compared to competitors's balloon lighting system such as Ingersoll Rand Balloon Light "BL2000" the light of GloBugTM series reaches further. For example, when BL2000 illuminates 15,000 sqft., GloBugTM “Cart type - GB114BC" can illuminate 30,000 spft. with the same brightness.

COVERRAGE RANGE

GB114BCDrum Shaped Balloon

Traditinal light tower1000W x 4 lamps

GB114BCStandard Balloon

GB114BCReflector Balloon

Distance from Light Souce

Illum

inat

ion

(Foo

t-can

dle)

15 feet

9.0

17.8

22.2

26.9

30 feet

2.86.6 7.56.7

45 feet

1.42.9 3.22.7

60 feet

0.91.7 1.91.5MQ "G

loBu

g" w

ith D

rum

Sha

ped

Ballo

onMQ

"Glo

Bug"

with

Reg

lecto

r Ball

oon

MQ "G

loBu

g" w

ith S

tand

ard

Ballo

on

IR "B

L200

0"

3 feet

22.3

36.4

54.8

94.8

GloBug Lighting System COMPARISON

GloBug Lighting System

Material of Balloon Envelope

Replacing

Washing

BALLOON ENVELOPE

The fan motor (blower) that inflates the balloon also acts as a cooling function. If the fan motor should break, Balloon alarm buzzer installed acts as a safety device. It will sound during normal operation if the balloon attempts to make contact with the lamp’s hot! surface. If this condition occurs, immediately place the GloBug’s ON/OFF switch in the OFF position.

Expendable parts such as balloon envelope and lamp can be quickly replaced without any tools and with less effort. Adjusting angle of the balloon, that is to change the illumination area, and storing balloon are operated easily.

The fabric made of a special material is very resistant to heat. As the test results show below, the fabric does not melt with any temperature at each part.

As a material of the balloon envelope of GloBugTM series, the most suitable fabric, is well diffusive, durable and heatproof, is selected. Maintenance to the balloon envelope is possible, making it last for a long time.

Common dirt such as mud will come out in washing machines. Detach the envelope from the balloon and put it in a laundry bag. You can wash it readily with most neutral detergent. In the case of greasy dirt, wipe off the dirt using grease and oil cleaning sprays and wash it in a washing machines.

Heatproof of balloonHeat resistanttemperature

320 to 360°F

Meltingtemperature

500°F

0°F 100°F 400°F

Surfaceof lamp

Lamp guard

Internal airof balloon

Surface of lampInternal air of balloon

Lamp guard

Thermostat

1. Unzip the zipper at the bottom and top of the balloon.

2. Remove the balloon envelope and cover with a new one.

3. Zip up the zipper.

FEATURES OF BALLOON LIGHT

Lumens

12,000hr

400hr

8.3A33.5A

8.50USD

128.00USD

Life hours

Required amperages

Annual Cost

■ LARGE LIGHT SOURCE FOR HIGH VISIBLITYBalloon Light is safe for surrounding traffic as large light is highly visible and seen from afar. The light that forms less darker shadow is also comfortable for the workers.

■ LONG-LIVED HIGH EFFICIENCY LAMP

Comparison between Metal halide and Halogen

HEATPROOF

Metal halide lamp being used for GloBugTM is high efficiency, longer life and stronger to vibration compared with Halogen lamp.

■ MESSAGE STRIP FOR ATTENTION (OPTION)Since it has integral Velcoro strips, message strip can be quickly installed with no tools. Special occasion balloon are avalable or design your won

As most of balloon lights that adopt halogen use 1000W x 2 bulbs, some comparisons with metal halides are counted with 2 halogen bulbs.

Message Strips fit on both sides of the balloon.

*7 hours/day x 365days

104,500lm

52,000lm (26,000lm x 2) 200%200%approx.approx.

Higher Light OutputHigher Light Output

1/41/4approx.approx.

More Energy CoservationMore Energy Coservation

1/151/15approx.approx.

Lower Cost ReductionLower Cost Reduction

3000%3000% Longer LifeLonger Lifeapprox.approx.

Metal halide lampHalogen lamp

GloBug Lighting System

Material of Balloon Envelope

Replacing

Washing

BALLOON ENVELOPE

The fan motor (blower) that inflates the balloon also acts as a cooling function. If the fan motor should break, Balloon alarm buzzer installed acts as a safety device. It will sound during normal operation if the balloon attempts to make contact with the lamp’s hot! surface. If this condition occurs, immediately place the GloBug’s ON/OFF switch in the OFF position.

Expendable parts such as balloon envelope and lamp can be quickly replaced without any tools and with less effort. Adjusting angle of the balloon, that is to change the illumination area, and storing balloon are operated easily.

The fabric made of a special material is very resistant to heat. As the test results show below, the fabric does not melt with any temperature at each part.

As a material of the balloon envelope of GloBugTM series, the most suitable fabric, is well diffusive, durable and heatproof, is selected. Maintenance to the balloon envelope is possible, making it last for a long time.

Common dirt such as mud will come out in washing machines. Detach the envelope from the balloon and put it in a laundry bag. You can wash it readily with most neutral detergent. In the case of greasy dirt, wipe off the dirt using grease and oil cleaning sprays and wash it in a washing machines.

Heatproof of balloonHeat resistanttemperature

320 to 360°F

Meltingtemperature

500°F

0°F 100°F 400°F

Surfaceof lamp

Lamp guard

Internal airof balloon

Surface of lampInternal air of balloon

Lamp guard

Thermostat

1. Unzip the zipper at the bottom and top of the balloon.

2. Remove the balloon envelope and cover with a new one.

3. Zip up the zipper.

FEATURES OF BALLOON LIGHT

Lumens

12,000hr

400hr

8.3A33.5A

8.50USD

128.00USD

Life hours

Required amperages

Annual Cost

■ LARGE LIGHT SOURCE FOR HIGH VISIBLITYBalloon Light is safe for surrounding traffic as large light is highly visible and seen from afar. The light that forms less darker shadow is also comfortable for the workers.

■ LONG-LIVED HIGH EFFICIENCY LAMP

Comparison between Metal halide and Halogen

HEATPROOF

Metal halide lamp being used for GloBugTM is high efficiency, longer life and stronger to vibration compared with Halogen lamp.

■ MESSAGE STRIP FOR ATTENTION (OPTION)Since it has integral Velcoro strips, message strip can be quickly installed with no tools. Special occasion balloon are avalable or design your won

As most of balloon lights that adopt halogen use 1000W x 2 bulbs, some comparisons with metal halides are counted with 2 halogen bulbs.

Message Strips fit on both sides of the balloon.

*7 hours/day x 365days

104,500lm

52,000lm (26,000lm x 2) 200%200%approx.approx.

Higher Light OutputHigher Light Output

1/41/4approx.approx.

More Energy CoservationMore Energy Coservation

1/151/15approx.approx.

Lower Cost ReductionLower Cost Reduction

3000%3000% Longer LifeLonger Lifeapprox.approx.

Metal halide lampHalogen lamp

$8.50

$128.00

Higher Light Output

Longer Life

Better Energy Conservation

Lower Operating Cost

Page 7: GloBug Light Towers · power cable Three-stage mast ... point lifting without removing attachments. ... The fabric made of a special materi al is very resistant to5 heat.

GloBug FeaturesGloBug Lighting System

Material of Balloon Envelope

Replacing

Washing

BALLOON ENVELOPE

The fan motor (blower) that inflates the balloon also acts as a cooling function. If the fan motor should break, Balloon alarm buzzer installed acts as a safety device. It will sound during normal operation if the balloon attempts to make contact with the lamp’s hot! surface. If this condition occurs, immediately place the GloBug’s ON/OFF switch in the OFF position.

Expendable parts such as balloon envelope and lamp can be quickly replaced without any tools and with less effort. Adjusting angle of the balloon, that is to change the illumination area, and storing balloon are operated easily.

The fabric made of a special material is very resistant to heat. As the test results show below, the fabric does not melt with any temperature at each part.

As a material of the balloon envelope of GloBugTM series, the most suitable fabric, is well diffusive, durable and heatproof, is selected. Maintenance to the balloon envelope is possible, making it last for a long time.

Common dirt such as mud will come out in washing machines. Detach the envelope from the balloon and put it in a laundry bag. You can wash it readily with most neutral detergent. In the case of greasy dirt, wipe off the dirt using grease and oil cleaning sprays and wash it in a washing machines.

Heatproof of balloonHeat resistanttemperature

320 to 360°F

Meltingtemperature

500°F

0°F 100°F 400°F

Surfaceof lamp

Lamp guard

Internal airof balloon

Surface of lampInternal air of balloon

Lamp guard

Thermostat

1. Unzip the zipper at the bottom and top of the balloon.

2. Remove the balloon envelope and cover with a new one.

3. Zip up the zipper.

FEATURES OF BALLOON LIGHT

Lumens

12,000hr

400hr

8.3A33.5A

8.50USD

128.00USD

Life hours

Required amperages

Annual Cost

■ LARGE LIGHT SOURCE FOR HIGH VISIBLITYBalloon Light is safe for surrounding traffic as large light is highly visible and seen from afar. The light that forms less darker shadow is also comfortable for the workers.

■ LONG-LIVED HIGH EFFICIENCY LAMP

Comparison between Metal halide and Halogen

HEATPROOF

Metal halide lamp being used for GloBugTM is high efficiency, longer life and stronger to vibration compared with Halogen lamp.

■ MESSAGE STRIP FOR ATTENTION (OPTION)Since it has integral Velcoro strips, message strip can be quickly installed with no tools. Special occasion balloon are avalable or design your won

As most of balloon lights that adopt halogen use 1000W x 2 bulbs, some comparisons with metal halides are counted with 2 halogen bulbs.

Message Strips fit on both sides of the balloon.

*7 hours/day x 365days

104,500lm

52,000lm (26,000lm x 2) 200%200%approx.approx.

Higher Light OutputHigher Light Output

1/41/4approx.approx.

More Energy CoservationMore Energy Coservation

1/151/15approx.approx.

Lower Cost ReductionLower Cost Reduction

3000%3000% Longer LifeLonger Lifeapprox.approx.

Metal halide lampHalogen lamp

Balloon MaterialThe GloBug ballons are fabricated from material that is durable, heat resistant, and easy to maintain.

The fan motor (blower) that inflates the balloon also provides a cooling function. Should the fan motor stop working, an audible alarm alerts the crew to the problem.

Heatproof Balloon — The heat resistant fabric will not melt, should it come into contact with any part of the light fixture.

GloBug Lighting SystemGloBug Lighting System

Material of Balloon Envelope

Replacing

Washing

BALLOON ENVELOPE

The fan motor (blower) that inflates the balloon also acts as a cooling function. If the fan motor shouldbreak, BALLOON ALARM BUZZER installed acts as a safety device. It will sound during normal operationif the balloon attempts to make contact with the lamp’s hot! surface. If this condition occurs, immediatelyplace the GloBug’s ON/OFF switch in the OFF position.

Expendable parts such as balloon envelope and lamp can be quickly replaced without any tools and withless effort. Adjusting angle of the balloon, that is to change the illumination area, and storing balloon areoperated easily.

The fabric made of a special material is very resistant to heat. As the test results show below, the fabricdoes not melt with any temperature at each part.

As a material of the balloon envelope of GloBugTM series, the most suitable fabric, is well diffusive, durableand heatproof, is selected. Maintenance to the balloon envelope is possible, making it last for a long time.

Common dirt such as mud will come out in washing machines. Detach the envelope from the balloon andput it in a laundry bag. You can wash it readily with most neutral detergent. In the case of greasy dirt, wipeoff the dirt using grease and oil cleaning sprays and wash it in a washing machines.

Heatproof of balloonHeat resistanttemperature

320 to 360°F

Meltingtemperature

500°F

0°F 100°F 400°F

Surfaceof lamp

Lamp guard

Internal airof balloon

Surface of lampInternal air

of balloon

Lamp guard

Thermostat

1. Unzip the zipper at the bottomand top of the balloon.

2. Remove the balloon envelopeand cover with a new one.

3. Zip up the zipper.

HEATPROOF

with Traditional Light Tower

with Balloon light competitor

COMPARISON

Compared to traditional 1000W x 4 class of light tower (Spotlight type), GloBugTM series can illuminate a largearea with more homogeneous light, even though the required power is the quarter at only 1000W. You canilluminate with safer and non-glare light at low cost since GloBugTM series eats much less fuel than 4000Wclass of light towers do. The followings is a comparison between Traditional light tower & GloBugTM "Cart type -GB114BC".

Compared to competitors's balloon lighting system such as Ingersoll Rand Balloon Light "BL2000" the light ofGloBugTM series reaches further. For example, when BL2000 illuminates 15,000 sqft., GloBugTM “Cart type -GB114BC" can illuminate 30,000 spft. with the same brightness.

COVERRAGE RANGE

GB114BCDrum Shaped Balloon

Traditinal light tower1000W x 4 lamps

GB114BCStandard Balloon

GB114BCReflector Balloon

Distance from Light Souce

Illum

inat

ion

(Foo

t-can

dle)

15 feet

9.0

17.8

22.2

26.9

30 feet

2.86.6 7.56.7

45 feet

1.42.9 3.22.7

60 feet

0.91.7 1.91.5MQ"G

loBu

g"wi

thDr

umSh

aped

Ballo

onMQ

"Glo

Bug"

with

Regl

ecto

rBall

oon

MQ"G

loBu

g"wi

thSt

anda

rdBa

lloon

IR"B

L200

0"

3 feet

22.3

36.4

54.8

94.8

The fan motor (blower) that inflates the balloon also provides a cooling function. Should the fan motor stop working, an audible alarm alerts the crew to the problem.

Washing — The balloon is easily removed by unzipping it from the base. It can be hand washed or machine washed, in a laundry bag with a neurtral detergent. Grease or oil stains should can be cleaned with cleaning sprays.

Replacement Balloons — Should the balloon require replacement it can be done quickly and without any tools. Balloons can be easily removed for storage; an integral protective cover is provided.

Balloon MaterialThe GloBug ballons are fabricated from material that is durable, heat resistant, and easy to maintain.

Heatproof Balloon — The heat resistant fabric is tested to make sure it does not melt, should it come into contact with any part of the light fixture.

Heatproof Balloon

Heat resistant temperature 320 to 360°F

Melting temperature

500°F

Surface of lamp

Lamp guard

Air inside balloon

0°F 100°F 400°F

1. Unzip the zipper at the bottom and top of the balloon.

2. Remove the balloon envelope and cover with a new one.

3. Zip up the zipper.

Surface of lampInternal air of balloon

Lamp guard

Thermostat

Surface of lampInternal air of balloon

Lamp guard

Old Image

New Image

Please replace the image as below.

GloBug Lighting System

Material of Balloon Envelope

Replacing

Washing

BALLOON ENVELOPE

The fan motor (blower) that inflates the balloon also acts as a cooling function. If the fan motor should break, Balloon alarm buzzer installed acts as a safety device. It will sound during normal operation if the balloon attempts to make contact with the lamp’s hot! surface. If this condition occurs, immediately place the GloBug’s ON/OFF switch in the OFF position.

Expendable parts such as balloon envelope and lamp can be quickly replaced without any tools and with less effort. Adjusting angle of the balloon, that is to change the illumination area, and storing balloon are operated easily.

The fabric made of a special material is very resistant to heat. As the test results show below, the fabric does not melt with any temperature at each part.

As a material of the balloon envelope of GloBugTM series, the most suitable fabric, is well diffusive, durable and heatproof, is selected. Maintenance to the balloon envelope is possible, making it last for a long time.

Common dirt such as mud will come out in washing machines. Detach the envelope from the balloon and put it in a laundry bag. You can wash it readily with most neutral detergent. In the case of greasy dirt, wipe off the dirt using grease and oil cleaning sprays and wash it in a washing machines.

Heatproof of balloonHeat resistanttemperature

320 to 360°F

Meltingtemperature

500°F

0°F 100°F 400°F

Surfaceof lamp

Lamp guard

Internal airof balloon

Surface of lampInternal air of balloon

Lamp guard

Thermostat

1. Unzip the zipper at the bottom and top of the balloon.

2. Remove the balloon envelope and cover with a new one.

3. Zip up the zipper.

FEATURES OF BALLOON LIGHT

Lumens

12,000hr

400hr

8.3A33.5A

8.50USD

128.00USD

Life hours

Required amperages

Annual Cost

■ LARGE LIGHT SOURCE FOR HIGH VISIBLITYBalloon Light is safe for surrounding traffic as large light is highly visible and seen from afar. The light that forms less darker shadow is also comfortable for the workers.

■ LONG-LIVED HIGH EFFICIENCY LAMP

Comparison between Metal halide and Halogen

HEATPROOF

Metal halide lamp being used for GloBugTM is high efficiency, longer life and stronger to vibration compared with Halogen lamp.

■ MESSAGE STRIP FOR ATTENTION (OPTION)Since it has integral Velcoro strips, message strip can be quickly installed with no tools. Special occasion balloon are avalable or design your won

As most of balloon lights that adopt halogen use 1000W x 2 bulbs, some comparisons with metal halides are counted with 2 halogen bulbs.

Message Strips fit on both sides of the balloon.

*7 hours/day x 365days

104,500lm

52,000lm (26,000lm x 2) 200%200%approx.approx.

Higher Light OutputHigher Light Output

1/41/4approx.approx.

More Energy CoservationMore Energy Coservation

1/151/15approx.approx.

Lower Cost ReductionLower Cost Reduction

3000%3000% Longer LifeLonger Lifeapprox.approx.

Metal halide lampHalogen lamp

GloBug Lighting System

Material of Balloon Envelope

Replacing

Washing

BALLOON ENVELOPE

The fan motor (blower) that inflates the balloon also acts as a cooling function. If the fan motor should break, Balloon alarm buzzer installed acts as a safety device. It will sound during normal operation if the balloon attempts to make contact with the lamp’s hot! surface. If this condition occurs, immediately place the GloBug’s ON/OFF switch in the OFF position.

Expendable parts such as balloon envelope and lamp can be quickly replaced without any tools and with less effort. Adjusting angle of the balloon, that is to change the illumination area, and storing balloon are operated easily.

The fabric made of a special material is very resistant to heat. As the test results show below, the fabric does not melt with any temperature at each part.

As a material of the balloon envelope of GloBugTM series, the most suitable fabric, is well diffusive, durable and heatproof, is selected. Maintenance to the balloon envelope is possible, making it last for a long time.

Common dirt such as mud will come out in washing machines. Detach the envelope from the balloon and put it in a laundry bag. You can wash it readily with most neutral detergent. In the case of greasy dirt, wipe off the dirt using grease and oil cleaning sprays and wash it in a washing machines.

Heatproof of balloonHeat resistanttemperature

320 to 360°F

Meltingtemperature

500°F

0°F 100°F 400°F

Surfaceof lamp

Lamp guard

Internal airof balloon

Surface of lampInternal air of balloon

Lamp guard

Thermostat

1. Unzip the zipper at the bottom and top of the balloon.

2. Remove the balloon envelope and cover with a new one.

3. Zip up the zipper.

FEATURES OF BALLOON LIGHT

Lumens

12,000hr

400hr

8.3A33.5A

8.50USD

128.00USD

Life hours

Required amperages

Annual Cost

■ LARGE LIGHT SOURCE FOR HIGH VISIBLITYBalloon Light is safe for surrounding traffic as large light is highly visible and seen from afar. The light that forms less darker shadow is also comfortable for the workers.

■ LONG-LIVED HIGH EFFICIENCY LAMP

Comparison between Metal halide and Halogen

HEATPROOF

Metal halide lamp being used for GloBugTM is high efficiency, longer life and stronger to vibration compared with Halogen lamp.

■ MESSAGE STRIP FOR ATTENTION (OPTION)Since it has integral Velcoro strips, message strip can be quickly installed with no tools. Special occasion balloon are avalable or design your won

As most of balloon lights that adopt halogen use 1000W x 2 bulbs, some comparisons with metal halides are counted with 2 halogen bulbs.

Message Strips fit on both sides of the balloon.

*7 hours/day x 365days

104,500lm

52,000lm (26,000lm x 2) 200%200%approx.approx.

Higher Light OutputHigher Light Output

1/41/4approx.approx.

More Energy CoservationMore Energy Coservation

1/151/15approx.approx.

Lower Cost ReductionLower Cost Reduction

3000%3000% Longer LifeLonger Lifeapprox.approx.

Metal halide lampHalogen lamp

Washing — The balloon is easily re moved by unzipping it from the base. It can be hand washed or machine washed, in a laundry bag with a neurtral detergent. Grease or oil stains should can be cleaned with cleaning sprays.

Replacement Balloons — Should the balloon require replacement it can be done quickly and without any tools. Balloons can be easily removed for storage; an integral protective cover is provided.

Comparision to Conventional Light TowersCompared to conventional light towers (4x1000 Watt bulbs), the GloBug illuminates a large area while using 75% less power. The following is a comparison between a conventional light tower and the GB114BC.

■ GLARE-FREE LIGHTING FOR TRAFIC SAFETY

Features of Balloon Light

Spot ligh Balloon Light Coverage Range of GB113BC

Spot Light Balloon Light

GloBugTM Lighting System gives enough light to a work area but eyes are never blinded by glare even if seeing the light directly. It is gentle to surrounding traffic.

■ WIDE COVERAGE RANGE WITH HOMOGENEOUS LIGHTINGCompared to Traditional Spotlight towers that concentrate the light to a fixed direction, GloBugTM series can radiate the homogeneous light far and wide from the balloon to all directions.

■ 360°ILLUMINATION WITHOUT BLIND SPOTComing from the whole balloon, the light reaches over 360 degrees and to a long distance homogeneously. Illuminating fixed direction or close to residential area, you can use a reflector balloon.

Facing back light, you cannot see conditions of the road behind the light.

As the balloon illuminates the whole area of the site, you can see conditions beyond the site. So it is safe.

Unit: footcandle, 1 grid: 50ft.

with Traditional Light Tower

with Balloon light competitor

Compared to traditional 1000W x 4 class of light tower (Spotlight type), GloBugTM series can illuminate a large area with more homogeneous light, even though the required power is the quarter at only 1000W. You can illuminate with safer and non-glare light at low cost since GloBugTM series eats much less fuel than 4000W class of light towers do. The followings is a comparison between Traditional light tower & GloBugTM "Cart type - GB114BC".

Compared to competitors's balloon lighting system such as Ingersoll Rand Balloon Light "BL2000" the light of GloBugTM series reaches further. For example, when BL2000 illuminates 15,000 sqft., GloBugTM “Cart type - GB114BC" can illuminate 30,000 spft. with the same brightness.

COVERRAGE RANGE

GB114BCDrum Shaped Balloon

Traditinal light tower1000W x 4 lamps

GB114BCStandard Balloon

GB114BCReflector Balloon

Distance from Light Souce

Illum

inat

ion

(Foo

t-can

dle)

15 feet

9.0

17.8

22.2

26.9

30 feet

2.86.6 7.56.7

45 feet

1.42.9 3.22.7

60 feet

0.91.7 1.91.5MQ "G

loBu

g" w

ith D

rum

Sha

ped

Ballo

onMQ

"Glo

Bug"

with

Reg

lecto

r Ball

oon

MQ "G

loBu

g" w

ith S

tand

ard

Ballo

on

IR "B

L200

0"

3 feet

22.3

36.4

54.8

94.8

GloBug Lighting System COMPARISON

Traditional Light Tower 1000W x 4 Lamps

GB114BC Standard Balloon

GB114BC Reflector Balloon

GB114BC Drum-Shaped Balloon

Comparison to Other Balloon DesignsCompared to the Ingersol l -Rand BL2000, the GloBug illuminates a much larger area. For example, the BL2000 illuminates 15,000 ft² while the GloBug GB114BC illuminates 30,000 ft² at the same brightness.

Illum

inat

ion

(foot

-can

dles

)

3 feet 15 feet 30 feet 45 feet 60 feet

■ GLARE-FREE LIGHTING FOR TRAFIC SAFETY

Features of Balloon Light

Spot ligh Balloon Light Coverage Range of GB113BC

Spot Light Balloon Light

GloBugTM Lighting System gives enough light to a work area but eyes are never blinded by glare even if seeing the light directly. It is gentle to surrounding traffic.

■ WIDE COVERAGE RANGE WITH HOMOGENEOUS LIGHTINGCompared to Traditional Spotlight towers that concentrate the light to a fixed direction, GloBugTM series can radiate the homogeneous light far and wide from the balloon to all directions.

■ 360°ILLUMINATION WITHOUT BLIND SPOTComing from the whole balloon, the light reaches over 360 degrees and to a long distance homogeneously. Illuminating fixed direction or close to residential area, you can use a reflector balloon.

Facing back light, you cannot see conditions of the road behind the light.

As the balloon illuminates the whole area of the site, you can see conditions beyond the site. So it is safe.

Unit: footcandle, 1 grid: 50ft.

with Traditional Light Tower

with Balloon light competitor

Compared to traditional 1000W x 4 class of light tower (Spotlight type), GloBugTM series can illuminate a large area with more homogeneous light, even though the required power is the quarter at only 1000W. You can illuminate with safer and non-glare light at low cost since GloBugTM series eats much less fuel than 4000W class of light towers do. The followings is a comparison between Traditional light tower & GloBugTM "Cart type - GB114BC".

Compared to competitors's balloon lighting system such as Ingersoll Rand Balloon Light "BL2000" the light of GloBugTM series reaches further. For example, when BL2000 illuminates 15,000 sqft., GloBugTM “Cart type - GB114BC" can illuminate 30,000 spft. with the same brightness.

COVERRAGE RANGE

GB114BCDrum Shaped Balloon

Traditinal light tower1000W x 4 lamps

GB114BCStandard Balloon

GB114BCReflector Balloon

Distance from Light Souce

Illum

inat

ion

(Foo

t-can

dle)

15 feet

9.0

17.8

22.2

26.9

30 feet

2.86.6 7.56.7

45 feet

1.42.9 3.22.7

60 feet

0.91.7 1.91.5MQ "G

loBu

g" w

ith D

rum

Sha

ped

Ballo

onMQ

"Glo

Bug"

with

Reg

lecto

r Ball

oon

MQ "G

loBu

g" w

ith S

tand

ard

Ballo

on

IR "B

L200

0"

3 feet

22.3

36.4

54.8

94.8

GloBug Lighting System COMPARISON

MQ

Glo

Bug

with

Sta

ndar

d B

allo

on

MQ

Glo

Bug

with

Refl

ecto

r Bal

loon

MQ

Glo

Bug

with

Dru

m-S

hape

d B

allo

on

Heatproof Balloon

Melting temperature

500°F

Surface of lamp

Lamp guard

Air inside balloon

0°F 100°F 400°F

Heat resistant temperature 320 to 360°F

Page 8: GloBug Light Towers · power cable Three-stage mast ... point lifting without removing attachments. ... The fabric made of a special materi al is very resistant to5 heat.

© C

OP

YR

IGH

T 2008, M

ULT

IQU

IP IN

C.

All features and specifications are subject to change without notice.MQGLOBUG-683 Rev. D (04-08)

MULTIQUIP INC.POST OFFICE BOX 6254CARSON, CA 90749310-537-3700 • 800-421-1244FAX: 310-537-3927E-MAIL: [email protected]

Your Multiquip dealer is:

Multiquip’s GloBug. You’ve seen the light.Light Output ChartsBal 115D — Drum Balloon (with Velcro Strips) Bal 120 — Standard Balloon Bal 120R — Reflector Balloon

Footcandles FeetBAL120 BAL120R BAL115D

10 24 27 27

5 34 34 36

2 55 52 57

1 79 71 82

0.5 107 96 110

0.25 135 118 168

50 ft. 50 ft. 50 ft.

GB-114BC GloBug GB-114BW GloBug Solo

Voltage 120V 120V

Amps 9.5 9.5

Lamp Type 1,000 watt Metal Halide (x1) 1,000 watt Metal Halide (x1)

Total luminous flux 112,000 lm 112,000 lm

Standard Balloon Diameter in. (mm) 47 (1200) 47 (1200)

Mast — Number of stages 4 3

Winch type Manual Gas shock absorbers

Dimensions LxWxH in. (mm) — Working

58 x 57 x 90 to 197 (1460x1450x2250 to 4980)

80 x 80 x 80 to 157 (203 x 203 x 203 to 399)

Dimensions LxWxH in. (mm) — Storage

41 x 32 x 66 (1040 x 800 x 1655)

25 x 25 x 72 (64 x 64 x 182)

Weight lb. (kg) 243 (110) 139 (63)

Ordering information

GB114BC — GloBug with cart (generator optional); includes BAL-120 Balloon

GB114BW — GloBug Solo (with stand); includes BAL-120 Balloon

BAL-115D — Drum Shaped Balloon with integral Velcro strips to hold BALD1 Message Strips

BALD1 — Blank Message Strip (11½" x 42") for BAL-115D (Two required per balloon)

Available Balloons:

BAL-120 — Standard

BAL-120R — Reflector

Optional special occasion balloons are available — or design your own. Call for details and pricing.

Specifications

Message Strips fit on both sides of the balloon!