GlobalProduct Selection Guide
SELECTION GUIDE INTRODUCTION
STARLINE® Track Busway, Manufactured by Universal Global, is quickly becoming the industry standard in customizable power distribution. It was designed to meet the rugged specification of the UL857, IEC60439 part 1 & 2, Busway and Associated Fittings, with the flexible features of track lighting. Systems run from 100 Amp to 800 Amp with isolated protective earth. It is the simple, versatile, fast and economical solution for supplying power to electrical loads and is unique because the busway can be instantly tapped at any location, with a variety of plug-in units. This Product Selection Guide was developed to help the design engineer understand and consider all of the options available with STARLINE Track Busway when designing a system. This guide is all-inclusive; however, UGC (Universal Global Corporation) excels at collaborating with design engineers to provide solutions for any application. If you have a need that is not found in this guide, please contact us at +1-724-597-7800 or email us at [email protected]. We will be happy to answer your questions over the telephone or schedule a visit with one of our local representatives. A CD version of this guide can also be ordered free via your local STARLINE Sales Representative or by visiting www.uecorp.com. Universal Global’s goal is to provide you with Flexible Power Solutions – no matter what your design strategy may be. We welcome any comments regarding additional material that you feel should be included to help gain a more comprehensive understanding of STARLINE Track Busway. Please direct comments to [email protected].
TABLE OF CONTENTS
SYSTEM SUBJECT PAGES
GM100 Standard 100 Amp / 415 Volt 1.1 – 1.7
GM100G / GM100NG/GM100N
100 Amp / 100% (G) or 200% (NG) Neutral / Isolated Ground/Neutral (N)
2.1 – 2.6
GM225 225 Amp / 415 Volt 3.1 – 3.7
GM250T5 250 Amp / 415 Volt 4.1 – 4.8
GM400 400 Amp / 415 Volt 5.1 – 5.8
GM800 800 Amp/415 Volt 6.1 – 6.8
All Plug-in Units 7.1 – 7.12
All Current Monitoring 8.1 – 8.3
All Application Briefs 9.1 – 9.9
All Specifications 10.1 – 10.8
Page 1.1 | www.StarlinePower.com
Sta
nd
ard
GM
10
0 A
mp
Sys
tem
to
41
5
Vol
ts
Pow
er F
eed
pag
e 1
.5
Hou
sin
g S
ecti
on
pag
e 1
.2
Acc
esso
ries
– C
losu
re S
trip
1.6
Wei
gh
t H
ook
1.7
Plu
g-I
n U
nit
s
pag
es 7
.1-7
.6
Inst
alla
tion
Too
l P
age
1.7
Su
pp
ort
Har
dw
are
p
age
1.6
End
Cap
p
age
1.6
End
Pie
ce
pag
e 1
.6
Cou
ple
r p
age
1.6
Elb
ow
pag
e 1
.3
Tee
pag
e 1
.4
4 p
ole
106
mm
60
mm
Track Busway housing sections consists of an extruded aluminium shell with channel type solid copper busbars contained in a full length PVC insulator mounted on one side on the interior wall. The aluminum extrusion acts as a 100% protective earth meeting IEC 60439-2. The housing has an open access slot over its entire length for the insertion of turn-n-lock plug-in units. The plug-in opening features finger safety to IP2X. Standard sections are 4 pole, 220…415 Volt. Each housing section has male stabs protruding at one end, which fit into the channels of the adjoining section. An installation tool GM100IT is used to force the stabs into the busbar channels for a solid spring-tempered electrical connection. MATERIAL: Extruded Aluminum RATINGS: IEC 60439-2
100% Protective Earth 100 Amp, 220…415
Volt IP2X, IP3X with
Protective Cover LENGTH: 1, 3 or 6 Metres.
Custom lengths upon request
VOLTAGE DROP:
Distributed Load Single Phase 16.5m
(.8PF) Three Phase 19m
(.8PF)
HOUSING SECTIONS
Catalog Number Sequence GM100–4PG–(L)-415
Length
1, 3 or 6 Metres or Custom Length
No. of Poles System size
106mm
60mm
Housing sections are joined by inserting male end into open female end so that stabs are parallel to female slots. Installation tool is then rotated to force stabs into slots. Refer to installation guide for procedure.
tool force
“Spring-pressure” channel busbar
Spring-pressure Spring-pressure
GM100 Series 100 Amps
Catalog Number Selection
Catalog No. Description Length Weight GM100-4PG-1-415 GM100-4PG-3-415 GM100-4PG-6-415
100 amp, 4 pole 100 amp, 4 pole 100 amp, 4 pole
1 m 3 m 6 m
3,5 kg
11,8 kg 23,6 kg
(L3) (L2)
(L1) (N)
Page 1.2 | www.StarlinePower.com
305mm 305mm 305mm 305mm
Right Elbow Left Elbow
Male to Male Adapter - GMAD100-4-415
4
254mm
Horizontal Elbow
Catalog Number Sequence GMEL100–4–(X)-415
Direction Right or Left
Number of System Poles
Elbow
Catalog Number Selection
Catalog No. Description Weight
GMEL100-4-L-415 GMEL100-4-R-415
Elbow, 4 pole, left Elbow, 4 pole, right
2,5 kg 2,5 kg
GMAD100-4-415
Male to Male Adapter, 4-pole
2,5 kg
Elbow Section Elbows are used for making a 90 degree in a busway run. Horizontal and vertical elbows are available. Specify right or left elbow according to the orientation of the busbars in the Busway sections to be connected. Refer to Layout GM100 for detail. Elbow sections are connected to adjacent Busway sections using Installation Tool GM100IT. Coupler set GMBHC-2, (ordered separately) is used to mechanically connect top and bottom of Tee section to adjacent busway. Plug-in unit cannot be inserted in elbow section open channel.
ELBOW SECTIONS
100 Amps
Page 1.3 | www.StarlinePower.com
Catalog Number Sequence GMT100-4–(XX)-415
Direction: External
or Internal Right or Left
Number of System Poles
Tee
Catalog Number Selection
Catalog No. Description Weight GMT100-4-ER-415 GMT100-4-EL-415 GMT100-4-IR-415 GMT100-4-IL-415
Tee, 4 pole, External Right Tee, 4 pole, External Left Tee, 4 pole, Internal Right Tee, 4 pole, Internal Left
3,6 kg 3,6 kg 3,6 kg 3,6 kg
Tee Section Tee sections are used for creating a 90 degree branch leg in a busway run. When laying out a system, specify the correct busbar orientation of the tee. Indicate right or left, external or internal busbars. External Tees are preferred. Refer to Layout GM100 for further detail. Tee sections are connected to adjacent busway sections using Installation Tool GM100IT. Coupler set GMBHC-2 (ordered separately) is used to mechanically connect top and bottom of tee section to adjacent busway. Plug-in unit cannot be inserted in tee section open channel.
TEE SECTIONS
100 Amp
External Right GMT100-4-ER-415
External Left GMT100-4-EL-415
Internal Right GMT100-4-IR-415
Internal Left GMT100-4-IL-415
610mm
305mm
Page 1.4 | www.StarlinePower.com
Catalog Number Sequence GM(XX)100–4-415V
EF= End Feed
TF =Top Feed CF =Center Feed
TB =Terminal Block
204mm
102mm
254mm
127mm
460mm 289mm
760mm
Page 1.5 | www.StarlinePower.com
Catalog Number Selection
Catalog No. Description Weight (kg)
GMEF100-4-415 End Feed, 4-Pole 2,72
GMTF100-4-415 Top Feed, 4-Pole [F–F] 5,67
GMCF100-4-415 Center Feed, 4-Pole [M-F] 5,67
GMTB100-100-4-415 Terminal Block, 100A, 4-Pole 2,95
TOP Feed / Center Feed The Top Feed Power unit comes as a completely pre-wired steel box to the top of a 760mm section of busway. A connection lug is located inside the box for field termination of supply power cable up to 50mm2. This unit is then connected to the male end of an adjoining busway section using Installation Tool GM100IT and Housing Coupler GMBHC-2, (ordered separately). Center Feed units are similar in construction. END Feed The standard end feed consists of a steel junction box with removable side, box lugs and shrink tubing. The power feed box slips over the male end of the first busway section and secured in place with mounting studs (supplied). Power supply cable is then terminated to each of the male busway stabs using the box lugs. BOTTOM Feed A bottom feed can be made by using a 100Amp Terminal Bock plug-in unit inserted and mounted below the busway.
POWER FEED UNITS Supplying Power to Busway
GM Series - 100 Amp
BOTTOM Feed Using Terminal Block
318mm 165mm
88.9mm
Installed with Couplers (GMBHC-2)
Ordered Separately
Page 1.6 | www.StarlinePower.com
CONNECTION ACCESSORIES
GM Series - 100 Amp
END CAP For covering the female end of 100 Busway. End Piece (EP) is used to cover male end.
3.875
2.5 PART NUMBER
GMEC-1 WEIGHT 0.2 lb
HOUSING COUPLERS
Connects adjacent Busway sections and/or end piece. One pair required. BHC-1 consists of two, 2-bolt couplers per set; one for the top and one for the bottom.
PART NUMBER
GMBHC-2 WEIGHT 0.8 lb
2-Bolt Coupler on top
4-Bolt Coupler on bottom
6”
END PIECE
The end piece is a 6 in. section of Busway housing, insulator and an end cap. It is used to cover the protruding copper busbar connector blades at the male end of a Busway run. An end Cap (EC) is used to cover female end.
PART NUMBER
GMEP-2
WEIGHT 0.8 lb
6”
OPTIONAL CLOSURE STRIP
Snaps into bottom access slot of B100 housing sections. Normally shipped in 10 ft lengths and can be field cut to fit exact desired length.
PART NUMBER
GMCS-1 - PVC GMCS-1-AL - Aluminum CUT LENGTH = 10 ft
Page 1.7 | www.StarlinePower.com
Used to connect two adjacent sections of Busway. Busway sections are first offset and butted together so that male stabs line up parallel to female busbar conductors. Installation tool is then inserted into joined intersection and rotated 90º forcing stabs into m-shaped female conductors making a spring-loaded, secure electrical connection. Mechanical Couplers (BHC) are then positioned over joined sections and tightened.
INSTALLATION TOOLS
GM Series - 100 Amp
For GM100 PART NUMBER GM100IT Weight 2.5 lbs
Female Busway section
Tool Pressure
Male Busway section
Sta
nd
ard
GM
10
0G
/G
M1
00
NG
10
0 A
mp
S
yste
m t
o 4
15
Vol
ts,
ISO
LATE
D P
RO
TEC
TED
EA
RTH
w
ith
10
0%
or
20
0%
Neu
tral
4
pol
e w
ith
Iso
late
d
Pro
tect
ive
Eart
h
106
mm
60
mm
Pow
er F
eed
p
age
2.5
-2.6
Acc
esso
ries
– C
losu
re S
trip
1.6
Wei
gh
t H
ook
1.7
Inst
alla
tion
Too
l p
age
1.7
Tee
p
age
2.4
Hou
sin
g S
ecti
on
pag
e 2
.2
Su
pp
ort
Har
dw
are
pag
e 1
.6
End
Cap
p
age
1.6
End
Pie
ce
pag
e 1
.6
Cou
ple
r p
age
1.6
Elb
ow
pag
e 2
.3
Plu
g-I
n U
nit
s p
age
7.7
-7.1
0
Page 2.1 | www.StarlinePower.com
Catalog Number Sequence GM100NG–4PG–(L)-415
Length 1, 3 or 6 Metres or custom length
Number of System Poles
System size: 100G: 100% neutral 100NG: 200% neutral
Catalog Number Selection
Catalog No. Description Length Weight
GM100G-4PG-1-415 GM100G-4PG-3-415 GM100G-4PG-6-415
100A/ISO PE, 4-pole 100A/ISO PE, 4-pole 100A/ISO PE, 4-pole
1 m 3 m 6 m
4,5 kg 13,6 kg
23,3 kg
GM100NG-4PG-1-415 GM100NG-4PG-3-415 GM100NG-4PG-6-415
100A/ISO PE, 200%N 100A/ISO PE, 200%N 100A/ISO PE, 200%N
1 m 3 m 6 m
5,2 kg
15,4 kg 29,5 kg
Track Busway housing section consists of an extruded aluminum shell with “spring-pressure” type copper channel busbars contained in a full length PVC insulator mounted on one side on the interior wall. Center conductor acts as 100% isolated protective earth path meeting IEC 60439-2. The housing has an open access slot over its entire length for the insertion of turn-n-lock, plug-in units. The plug-in opening features finger safety to IP2X. Housing configurations are 4-pole, 220…415 volt. The housing sections have male stabs protruding at one end, which fit into the channels of the adjoining section. An installation tool GM225IT is used to force the stabs into the busbar channels for a solid “spring-loaded” electrical connection. MATERIAL: Extruded Aluminum RATINGS: 100% Isolated
Protective Earth 100 Amp, 415 Volt GM100NG: 200 Amp Neutral GM100G: 100 Amp Neutral IP2X, IP3X with cover LENGTH: 1, 3 or 6 Metres.
Custom lengths upon request.
VOLTAGE Distributed load DROP: Single Phase 16.5m
(.8PF) Three Phase 19m
(.8PF) .
HOUSING SECTIONS
106mm
Housing sections are joined by inserting the male end into the open female end so that stabs are parallel to female slots. The installation tool is then rotated to force stabs into slots. Refer to installation guide for procedure.
Tool Force
(L3)
(L2)
(L1)
(N)
60mm
“Spring-pressure”
channel busbar
spring pressure spring pressure
ISO PE
Page 2.2 | www.StarlinePower.com
GM100G/GM100NG Series, 100 Amps Isolated Protective Earth
Catalog Number Sequence GMEL100NG–4–(X)-415
Direction
Right or Left
Number of System Poles
Elbow System size: 100NG or 100G
Catalog Number Selection
Catalog No. Description Weight
GMEL100NG-4-L-415 GMEL100NG-4-R-415 GMEL100G-4-L-415 GMEL100G-4-R-415
Elbow, 4-pole, ISO PE, 200%N, left Elbow, 4-pole, ISO PE, 200%N, right Elbow, 4-pole, ISO PE, 200%N, left Elbow, 4-pole, ISO PE, 200%N, right
2,5 kg 2,5 kg 2,1 kg 2,1 kg
Elbow Section Elbows are used for making a 90 degree in a busway run. Horizontal and vertical elbows are available. Specify right or left elbow according to the orientation of the busbars in the busway sections to be connected. Refer to Layout GM100 for detail. Elbow sections are connected to adjacent busway sections using Installation Tool GM100IT. Coupler set GMBHC-2, (ordered separately) is used to mechanically connect top and bottom of tee section to adjacent busway. Plug-in unit cannot be inserted in elbow section open channel.
GM100G/GM100NG/100 Amp Isolated Protective Earth
ELBOW SECTIONS
305mm 305mm 305mm 305mm
Right Elbow Left Elbow
Horizontal Elbow
Installed with couplers
(ORDERED SEPARATELY)
Page 2.3 | www.StarlinePower.com
Catalog Number Sequence GMT100-4–(XX)-415
Direction: External
or Internal Right or Left
Number of System Poles
Tee System Size 100NG or 100G
Catalog Number Selection Examples
Catalog No. Description Weight GMT100NG-4-IL-415 GMT100NG-4-EL-415 GMT100NG-4-IR-415 GMT100NG-4-ER-415 GMT100G-4-IL-415 GMT100G-4-EL-415 GMT100G-4-IR-415 GMT100G-4-ER-415
Tee, 4 pole, 200%N, Internal Left Tee, 4 pole, 200%N, External Left Tee, 4 pole, 200%N, Internal Right Tee, 4 pole, 200%N, External Right Tee, 4 pole, Internal Left Tee, 4 pole, ISO PE, External Left Tee, 4 pole, ISO PE, Internal Right Tee, 4 pole, ISO PE, External Right
4,2 kg 4,2 kg 4,2 kg 4,2 kg 4 kg 4 kg 4kg 4kg
Tee Section Tee sections are used for creating a 90 degree branch leg in a busway run. When laying out a system, specify the correct busbar orientation of the tee. Indicate right or left, external or internal busbars. Tee sections are connected to adjacent busway sections using an installation tool GM100IT. Housing Coupler set GMBHC-2, page 7.1 (ordered separately) is used to mechanically connect top and bottom of tee section to adjacent busway. Plug-in unit cannot be inserted in tee section open channel. Plug-in unit cannot be inserted in tee section open channel.
TEE SECTIONS
GM100G/GM100NG/100 Amps Isolated Protective Earth
External Right -ER
External Left -EL
Internal Right -IR
Internal Left -IL
610mm
305mm
Page 2.4 | www.StarlinePower.com
Catalog Number Sequence GMEF100NG–4-415V
Number of System Poles
EF =End Feed
System Size: 100NG or 100G
Catalog Number Selection
Catalog No. Description Weight (kg)
GMEF100NG-4-415 GMEF100G-4-415 GMEF100NG-4M-415 GMEF100G-4M-415
End Feed, 4-Pole, ISO PE, 200%N End Feed, 4-Pole, ISO PE End Feed, 4-Pole, ISO PS, 200%N, Male End End Feed, 4-Pole, ISO PE, Male End
7,6 kg 7,6 kg 7,6 kg
7,6 kg
End Power Feed Units Standard end power feed units connect to the male end of the busway. Factory assembled unit consists of a 305mm X 406mm X 127mm steel junction box, with removable side, connected to a 305mm section of busway. It includes Phase, Neutral connection lugs and shrink tubing for wires up to 150mm2. Chassis earth and isolated earth lugs allow wires up 67, 42mm² respectively. Units for connection to female busway ends are also available. End power feed units are connected to adjacent busway sections using Installation Tool GMB225IT and Housing Coupler Set GMBHC-2 (ordered separately). Special need power feed units for confined spaces as found in mission critical data centers can also be designed and fabricated, minimum quantities required.
END POWER FEED UNITS Supplying Power to End of Busway
Data Center custom units can also be fabricated with minimum quantities
Assembled with Busway Section
Installed with couplers
406mm
127mm
305mm
305mm
GM100G/GM100NG/100 Amps Isolated Protective Earth
Page 2.5 | www.StarlinePower.com
Catalog Number Sequence GM(XX)100NG–(P)-415V
Number of System Poles
TF =Top Feed CF =Center Feed
127mm
460mm 289mm
762mm
Catalog Number Selection
Catalog No. Description Weight (kg)
GMTF100NG-4-415 GMTF100G-4-415
Top Feed, 4-Pole, 200%N, ISO PE [F-F] Top Feed, 4-Pole, ISO PE, [F-F]
7,48 kg
GMCF100NG-4-415 GMCF100G-4-415
Center Feed, 4-Pole, 200%N, ISO PE, [M-F] Center Feed, 4-Pole, ISO PE [M-F]
9,07 kg
Top Power Feed Units Standard Top Power Feed units connect to the top of the busway. Factory assembled units consists of a 460mm X 289mm X 127mm steel junction box, with removable top, mounted on top of a 762mm section of busway. Top Feed Power units can be on end of busway run by connecting to adjacent busway sections using Installation Tool GM225IT and Housing Coupler Set GMBHC-2. Center Feed units can also be used as top power supply point anywhere along busway run by connecting to adjacent busway sections at both ends.
POWER FEED UNITS Supplying Power to Busway
GM100G/GM100NG/100 Amp Isolated Protective Earth
Installed with Couplers (GMBHC-2)
Ordered Separately
Page 2.6 | www.StarlinePower.com
4 p
ole
End
Pie
ce
pag
e 1
.6
End
Cap
p
age
1.6
S
up
por
t H
ard
war
e p
age
1.6
Hou
sin
g S
ecti
on
pag
e 3
.2
Tee
p
age
3.4
Pow
er F
eed
p
age
3.5
-3.7
Plu
g-I
n U
nit
s p
age
7.1
-7.1
0
Elb
ow
pag
e 3
.3
Cou
ple
r p
age
1.4
Acc
esso
ries
– C
losu
re S
trip
1.6
W
eig
ht
Hoo
k 1
.7
Page 3.1a | www.StarlinePower.com
60
mm
106
mm
GM
22
5,
22
5 A
mp
Sys
tem
, 4
15
Vol
ts
Inst
alla
tion
Too
l p
age
1.7
Protective Earth Options
Page 3.1b l www.StarlinePower.com
FAQ CHASSIS EARTH, DEDICATED EARTH, ISOLATED EARTH
CHASSIS EARTH Uses aluminium housing as 100% rated earth path, and no extra copper bar.
ISOLATED EARTH 6hr receptacles position in plugs. Chassis earth isolated from copper earth bar. Isolated earth carried back to panel by others.
DEDICATED EARTH Extra bar in busway for earth. Everything tied together inside plugs. Chassis and dedicated earth bar at same potential.
GM100 GM225
T5
GM100G
T5G
GM100G
T5G
Catalog Number Sequence GM225–4PG–(L)-415
Length
1, 3 or 6 Metres or Custom Length
No. of Poles System size
Spring-pressure
Catalog Number Selection
Catalog No. Description Length Weight
GM225-4PG-1-415 GM225-4PG-3-415 GM225-4PG-6-415
225 Amp, 4-pole 225 Amp, 4-pole 225 Amp, 4-pole
1 m 3 m 6 m
5 kg 15 kg 29 kg
Track Busway housing section consists of an extruded aluminum shell with “spring -pressure” type copper channel busbars contained in a full length PVC insulator mounted on one side on the interior wall. The aluminum extrusion acts as a 100% protective earth meeting IEC 60439-2. The housing has an open access slot over its entire length for the insertion of turn-n-lock plug-in units. The plug-in opening features finger safety to IP2X. Housing configurations are 4-pole, 220…415 Volt rating. Each housing section has male stabs protruding at one end, which fit into the channels of the adjoining section. An installation tool GM225IT is used to force the stabs into the busbar channels for a solid spring-tempered electrical connection. MATERIAL: Extruded Aluminum RATINGS: IEC 60439-2
100% Protective Earth 225 Amp, 220…415
Volt IP2X, IP3X with Cover LENGTH: 1, 3 or 6 Metres.
Custom lengths upon request
VOLTAGE DROP: Distributed Load
Single Phase 12.2m (.8PF)
Three Phase 14.3m (.8PF)
HOUSING SECTIONS
106mm
60mm
Housing sections are joined by inserting male end into open female end so that stabs are parallel to female slots. Installation tool is then rotated to force stabs into slots. Refer to installation guide for procedure.
Tool Force
“Spring-pressure” channel busbar
Spring-pressure (L3) (L2)
(L1) (N)
GM225 Series - 225 Amp
Page 3.2 | www.StarlinePower.com
305mm 305mm
305mm 305mm
Right Elbow Left Elbow
Horizontal Elbow
Catalog Number Sequence GMEL225-4–(X)-415
Direction Right or Left
Number of System Poles
Elbow
Catalog Number Selection
Catalog No. Description Weight GMEL225-4-L-415 GMEL225-4-R-415
Elbow, 4-pole, left Elbow, 4-pole, right
2,5 kg 2,5 kg
Elbow Sections Elbows are used for making a 90 degree horizontal turn in a busway run. Specify right or left elbow according to the orientation of the busbars in the busway sections to be connected. Elbow sections are connected to adjacent busway sections using Installation Tool GM225IT. Coupler set GMBHC-2, (ordered separately) is used to mechanically connect top and bottom of tee section to adjacent busway. Plug-in unit cannot be inserted in elbow section open channel.
ELBOW SECTIONS
225 Amps
Installed with couplers (ORDERED SEPARATELY)
Page 3.3 | www.StarlinePower.com
Catalog Number Sequence GMT225-4–(XX)-415
Direction: External
or Internal Right or Left
Number of System Poles System Size
Tee
Catalog Number Selection
Catalog No. Description Weight GMT225-4-IL-415 GMT225-4-EL-415 GMT225-4-IR-415 GMT225-4-ER-415
Tee, 4 pole, Internal Left Tee, 4 pole, External Left Tee, 4 pole, Internal Right Tee, 4 pole, External Right
9,2 kg 9,2 kg 9,2 kg 9,2 kg
Tee Section Tee sections are used for creating a 90 degree branch leg in a busway run. When laying out a system, specify the correct busbar orientation of the tee. Indicate right or left, external or internal busbars. Tee sections are connected to adjacent busway sections using Installation Tool GM225IT. The Coupler set GMBHC-2 (ordered separately) is used to mechanically connect top and bottom of tee section to adjacent busway. Plug-in unit cannot be inserted in tee section open channel.
TEE SECTIONS
225 Amp
External Right GMT225-4-ER-415
External Left GMT225-4-EL-415
Internal Right GMT225-4-IR-415
Internal Left GMT225-4-IL-415
610mm
305mm
Page 3.4 | www.StarlinePower.com
Catalog Number Sequence GMEF225–4-415V
Number of System Poles
EF =End Feed
Catalog Number Selection
Catalog No. Description Weight (kg)
GMEF225-4-415 GMEF225-4M-415
End Feed, 4-Pole End Feed, 4-Pole, MALE END
7,48 kg 7,48 kg
End Power Feed Units Standard End Power Feed units connect to the male end of the busway. Factory assembled unit consists of a 305mm X 406mm X 127mm steel junction box, with removable sides, connected to a 305mm section of busway. It includes connection lugs and shrink tubing for wires up to 150mm2. Ground lug connection for wires up to 67mm2. Units for connection to female busway ends are also available. End Power Feed units are connected to adjacent busway sections using Installation Tool GM225IT and Housing Coupler Set GMBHC-2 (ordered separately). Special need power feed units for confined spaces as found in Mission Critical Data Centers can also be designed and fabricated, minimum quantities required.
POWER FEED UNITS Supplying Power to End of Busway
225 Amp
406mm
127mm
Assembled with Busway Section
305mm
305mm
GMEF225-4M
GMEF225-4
Page 3.5 | www.StarlinePower.com
Catalog Number Sequence GM(XX)225–4–415V
Number of System Poles
TF =Top Feed CF =Center Feed
127mm
460mm 289mm
762mm
Catalog Number Selection
Catalog No. Description Weight (kg)
GMTF225-4-415 GMTF225-4R-415
Top Feed, 4-Pole Top Feed, 4-Pole, Rev KO
7,48 7,48
GMCF225-4-415 GMCF225-4R-415
Center Feed, 4-Pole Center Feed, 4-Pole, Rev KO
9,07 9,07
Top Power Feed Units Standard Top Power Feed units provide connections at the top side of the busway. Factory assembled unit consists of a 460mm X 289mm X 127mm steel junction box, with removable top, mounted on top of a 762mm section of busway. Top Feed Power units can be on the end of a busway run by connecting to the adjacent busway sections using Installation Tool GM225IT and Housing Coupler Set GMBHC-2. ‘R’ versions reverse position of conduit KO’s for easier field wiring. Center Power Feed Center Feed units can also be used as a top power supply point anywhere along a busway run by connecting to adjacent busway sections at both ends. ‘R’ versions reverse position of conduit KO’s (knock outs) for easier field wiring. Contact UEC for further information.
POWER FEED UNITS Supplying Power at top of Busway
Installed with Couplers (GMBHC-2)
Ordered Separately
225 Amp
Page 3.6 | www.StarlinePower.com
Catalog Number Sequence GM(CF)225-4-2N-(DL)-415V
Dual Lug (Option)
Dual Neutral
Number of Poles
System
Center Feed
Catalog Number Selection
Catalog No. Description
GMCF225-4-2N-415 GMCF225-4R-2N-415 GMCF225-4-2N-DL-415 GMCF225-4R-2N-DL415
Ctr. Feed / DBL Neutral Ctr. Feed / DBL Neutral / Rev KO Ctr. Feed / DBL Neutral / Dual Lug Ctr. Feed / DBL Neutral / Dual Lug / Rev KO
Dual Neutral Center Feed Standard Dual Neutral Center Feed units connect power at the top of the busway at any point along a busway run. These are used where excess neutral currents are a concern. Factory assembled units consists of a 460mm x 289mm x 127mm steel junction box, with a removable top, mounted on top of a 762mm section of busway. Dual Neutral Center Feed units can be connected between adjacent busway sections using the GM225IT Installation Tool and Coupler Set GMBHC-2. Optional Dual Lug Terminal Blocks available which facilitates daisy-chaining power supplies. ‘R’ versions reverse position of conduit KO’s (Knock Outs) for easier field wiring. Refer to Application Briefs for further information on Dual Neutral Center Feeds.
DUAL NEUTRAL CENTER POWER FEED
225 Amp
762mm
127mm
289mm
460mm
Page 3.7 | www.StarlinePower.com
Sta
nd
ard
GM
25
0T5
, G
M2
50
T5N
, G
M2
50
T5N
G,
GM
25
0T5
G
25
0 A
mp
Sys
tem
, 4
15
Vol
ts
Pow
er F
eed
pag
e 4
.5-4
.6
Hou
sin
g S
ecti
on
pag
e 4
.2
Inst
alla
tion
Too
l p
age
4.8
Su
pp
ort
Har
dw
are
pag
e 4
.7
End
Cap
pag
e 4
.7
Tee
Pag
e 4
.4
Hou
sin
g
Cou
ple
r p
age
5.8
Elb
ow p
age
4.3
Plu
g-I
n U
nit
s p
age
7.7
-7.1
0
Bu
s C
onn
ecto
r
pag
e 4
.8
GM
250T
5NG
show
n 25
0 A
mp
Syst
em, 4
15 V
olt
(OV
ER
SIZ
ED
NE
UT
RA
L &
IS
OL
ATE
D P
RO
TE
CT
IVE
E
AR
TH
)
Page 4.1 | www.StarlinePower.com
128
mm
12
8 m
m
108
mm
10
8 m
m
6.4
Acc
esso
ries
– C
losu
re S
trip
4.7
GM
250T
5NG
G
M25
0T5
Protective Earth Options
Page 4.1b l www.StarlinePower.com
FAQ CHASSIS EARTH, DEDICATED EARTH, ISOLATED EARTH
CHASSIS EARTH Uses aluminium housing as 100% rated earth path, and no extra copper bar.
ISOLATED EARTH 6hr receptacles position in plugs. Chassis earth isolated from copper earth bar. Isolated earth carried back to panel by others.
DEDICATED EARTH Extra bar in busway for earth. Everything tied together inside plugs. Chassis and dedicated earth bar at same potential.
GM100 GM225
T5
GM100G
T5G
GM100G
T5G
Page 5.2 l www.uecorp.com
HOUSING SECTIONS
Track Busway housing sections consist of an extruded Aluminium shell with “spring-pressure” type copper channel busbars contained in a full length halogen-free insulator mounted on the interior walls. The Aluminium extrusion acts as a 100% protective earth meeting IEC 60439-2. Each housing has a continuous access slot over its entire length for the insertion of turn-n-lock plug-in units. The plug-in opening features finger safety to IP2X. Housing configurations include 3 or 4-pole varieties 220…415V, optional isolated protective earth, and optional oversize (200%) neutral. The housing sections join together using Bus Connectors which fit into the channels of the adjoining section. An Installation Tool is used to force the blades into the busbar channels for a solid “spring-pressure” electrical connection.
MATERIAL: Extruded Aluminium RATINGS: 100% Protective Earth 250 Amps GM250T5/GM250T5G 415 Volt GM250T5N/GM250T5NG 415 Volt LENGTH: 3 m OR 6 m VOLTAGE DROP: Distributed load, .8PF Single Phase 14.9 m per Volt Three Phase 17.6 m per Volt
Catalog Number Sequence GM250T5–(X)PG–(L)
Length 3 or 6 Metres or custom length No. of Poles System size = 250 Amps G - Isolated PE NG - ISO PE & 200% Neutral
Housing sections are joined by inserting the Bus Connector which fits into the channels of the adjoining section. The installation tool is then rotated to force blades into slots.
108mm
“Spring-pressure” channel busbar US Pat. # 6,039,584
Spring pressure Spring pressure
(L2)
(L1) (N)
(L3)
L3)
(PE)
128mm
Tool Force
Catalog No. Description Length Weight
GM250T5-4PG-3-415 250A, 4-pole 3 m 18.5 kg
GM250T5-4PG-6-415 250A, 4-pole 6 m 37 kg
GM250T5G-4PG-3-415 250A, 4P/Iso PE 3 m 20.8 kg
GM250T5G-4PG-6-415 250A, 4P/Iso PE 6 m 41.7 kg
GM250T5N-4PG-3-415 250A, 4P/200%N 3 m 21.3 kg
GM250T5N-4PG-6-415 250A, 4P/200%N 6 m 42.6 kg
GM250T5NG-4PG-3-415 250A, 4P/ISO PE/200%N 3 m 23.1 kg
GM250T5NG-4PG-6-415 250A, 4P/ISO PE/200%N 6 m 46.2 kg
GM250T5, GM250T5N, GM250T5G, GM250T5NG Systems
GM250T5NG shown
Page 4.2 | www.StarlinePower.com
GM250T5, GM250T5N, GM250T5G, GM250T5NG Systems
ELBOW SECTION
Catalog No. Description Weight GMEL250T5-4-L-415 Elbow, 4-pole, left 5.9 kg GMEL250T5-4-R-415 Elbow, 4-pole, right 5.9 kg GMEL250T5G-4-L-415 Elbow, 4-pole/ISO PE, left 6.1 kg GMEL250T5G-4-R-415 Elbow, 4-pole/ISO PE, right 6.1 kg GMEL250T5N-4-L-415 Elbow, 4-pole/200%N, left 6.4 kg GMEL250T5N-4-R-415 Elbow, 4-pole/200%N, right 6.4 kg GMEL250T5NG-4-L-415 Elbow, 4-pole/ISO PE/200%N,
left 6.6 kg
GMEL250T5NG-4-R-415 Elbow, 4-pole/ISO PE/200%N, right
6.6 kg
Elbow Section An Elbow is used for making a horizontal 90 degree change of direction in a Busway run. Specify right or left elbow according to the orientation of the polarizing stripe in the Busway sections to be connected. Plug-in unit cannot be inserted in elbow section open channel. CONNECTION ACCESSORIES:
(Ordered Separately) Joint Kit (GMJK250T5 series) is used to make mechanical and electrical connections to adjacent Busway sections.
Catalog Number Sequence GMEL250T5-(P)–(X)-415 Direction (Right, Left)
Number of Poles
System size = 250 Amps G – Isolated PE NG – ISO PE & 200% Neutral Elbow
Horizontal Elbow -R Version Shown
Elbow shown with Joint Kits installed
GMEL250T5-4-L Internal Elbow
GMEL250T5-4-R External Elbow
Polarizing Stripe
Top View Shown
Page 4.3 | www.StarlinePower.com
TEE SECTION
Elbow Section A Tee is used for making a horizontal 90 degree branch leg in a Busway run. Specify either internal or external, and either right or left tee according to the orientation of the polarizing stripe in the Busway sections to be connected. Plug-in unit cannot be inserted in tee section open channel. CONNECTION ACCESSORIES:
(Ordered Separately) A Joint Kit (GMJK250T5 series) is used to make mechanical and electrical connections to adjacent Busway sections.
Catalog Number Sequence GMT250T5-(P)-(XX) Direction External or Internal Right or Left
No. of Poles
System size = 250 Amps G – Isolated PE NG – ISO PE & 200% Neutral
Tee
External Left -EL
Internal Right -IR
Internal Left -IL
GM250T5, GM250T5N, GM250T5G, GM250T5NG Systems
External Right -ER
Catalog No. Description Weight GMT250T5-4-IL Tee, 4-pole, Internal Left 8.9 kg
GMT250T5-4-EL Tee, 4-pole, External Left 8.9 kg
GMT250T5-4-IR Tee, 4-pole, Internal Right 8.9 kg
GMT250T5-4-ER Tee, 4-pole, External Right 8.9 kg
Polarizing Stripe
Top View Shown
Page 4.4 | www.StarlinePower.com
END POWER FEED UNITS Supplying Power to End of Busway
Catalog No. Description Weight GMEF250T5-4-415 End Feed, 4-Pole 8.0 kg GMEF250T5-4R-415 End Feed, 4-Pole/Rev 8.0 kg GMEF250T5G-4-415 End Feed, 4-Pole/Iso PE 8.2 kg GMEF250T5G-4R-415 End Feed, 4-Pole/Iso PE/Rev 8.2 kg GMEF250T5N-4-415 End Feed, 4-Pole/200% N 8.6 kg GMEF250T5N-4R-415 End Feed, 4-Pole/200% N/Rev 8.6 kg GMEF250T5NG-4-415 End Feed, 4-Pole/ISO PE/200% N 8.9 kg GMEF250T5NG-4R-415 End Feed, 4-Pole/ISO PE/200%
N/Rev 8.9 kg
End Power Feed Units Standard End Power Feed units connect to the end of any busway section. Factory assembled unit consists of a 305 X 406 X 165mm steel junction box with removable sides connected to a 305mm section of busway. The assembly includes connection lugs for wires up to 152mm2. Chassis earth isolated earth allow wires up to 67mm2 and 42mm2 respectively. Reverse End feed units for connection to opposite end of busway section (polarizing stripe faces to right as viewed from junction box end of unit). End Power Feed units are connected to adjacent Busway sections using Housing Coupler and Bus Connector which are sold separately. (Joint Kit – T5 Series) Special need Power Feed units for confined spaces as might be found in Mission Critical Data Centers can also be designed and fabricated, requiring minimum quantities. Reference page 5.1b for dedicated ground application. Contact UEC representative for further information.
Catalog Number Sequence GMEF250T5–(P)(R) Reverse
System Poles System size = 250 Amps G – Isolated PE NG-ISO PE & 200% Neutral DG – Dedicated Earth End Feed
Standard
Reversed
As shown on layout dwg
GM250T5, GM250T5N, GM250T5G, GM250T5NG Systems
Assembled with 305mm of Busway
Page 4.5 | www.StarlinePower.com
TOP POWER FEED Supplying Power to TOP of Busway
Catalog No. Description Weight GMTF250T5-4-415 Top Feed, 4-Pole 19.1 kg GMTF250T5-4R-415 Top Feed, 4-Pole/Rev 19.1 kg GMTF250T5G-4-415 Top Feed, 4-Pole/ISO PE 19.8 kg GMTF250T5G-4R-415 Top Feed, 4-Pole/ISO PE/Rev 19.8 kg GMTF250T5N-4-415 Top Feed, 4-Pole/200% N 20.0 kg GMTF250T5N-4R-415 Top Feed, 4-Pole/200% N/Rev 20.0 kg GMTF250T5NG-4-415 Top Feed, 4-Pole/ISO PE/200% N 20.7 kg GMTF250T5NG-4R-415 Top Feed, 4-Pole/ISO PE/200% N/Rev 20.7 kg
Top Power Feed Units Standard Top Power Feed units supply power from the topside of the Busway. Factory assembled unit consists of a 508 X 305 X 203 mm steel junction box, with hinged cover, mounted on top of a 914mm section of Busway. Top Feed Power units can be positioned at end or anywhere along a busway run. Connections to adjoining busway sections are made by the standard means, requiring housing couplers and bus connectors which are sold separately. (Joint Kit – T5 Series)
Catalog Number Sequence GMTF250T5–(P)-415
System Poles System size = 250Amps G– Isolated PE NG– ISO PE & 200% Neutral
Top Feed
GM250T5, GM250T5N, GM250T5G, GM250T5NG Systems
Standard (R) Reversed
Hinged side
Hinged side
Busway Section
Page 4.6 | www.StarlinePower.com
CONNECTION ACCESSORIES
END CAP For covering the end of GM250T5 Busway run.
GM250T5, GM250T5N, GM250T5G, GM250T5NG Systems
PART NUMBER GMEC250T5 WEIGHT 0.2 kg
PART NUMBER GMBRHT5-1 GMBHT5-1 WEIGHT 0.5 kg.
ALUMINIUM /PVC CLOSURE STRIP Affixes with an adhesive backing to access slot of GM250T5 housing sections. Normally shipped in 3m lengths.
PART NUMBER GMCST5-AL GMCST5-1 WEIGHT 0.67 kg/m. 0.44 kg/m.
HANGER BOLTS Threaded Rod (GMBRHT5-1)
For mounting to M12 threaded rod. Twist-in design. Can be inserted anywhere along the full access slot on the top of the Busway. Maximum hanger support spacing is every 3m. Standard (GMBHT5-1)
For mounting to strut or other flat surfaces. Twist-in design. Can be inserted anywhere along the full access slot on the top of the Busway. Maximum hanger support spacing is every 3m.
GMBRHT5-1
GMBHT5-1
Page 4.7 | www.StarlinePower.com
INSTALLATION TOOL
INSTALLATION TOOL: Used to install bus connector between two adjacent sections of Busway. Busway sections are butted together and the top housing coupler is installed. The Bus connector is inserted, centered, and seated in the slot of the Busway joint. The installation tool is inserted into jointed intersection and rotated 90º forcing stabs into female conductors making a ‘spring-pressure’, secure electrical connection. Bottom housing coupler is then centered and installed.
JOINT KIT/INSTALLATION TOOL
For Standard T5 Series Installation Tool Part Number Weight GMT5IT 1.4 kg
GM250T5, GM250T5N, GM250T5G, GM250T5NG Systems
Systems
Busway Section
Tool Pressure
Busway section
JOINT KIT For connection of adjacent Busway sections. One Kit required at each joint. Each Kit is comprised of a housing coupler pair and bus connector set. Specify configuration to match busway configuration. HOUSING COUPLER: Consists of two, 12-screw couplers – one for the top of the housing and one for the bottom. Housing Couplers are polarized with a stripe corresponding to the polarization of the housing. BUS CONNECTOR: Copper blades secured to insulating mounting plate. Left and Right set, makes electrical connection between sections.
PART NUMBER GMJK250T5-1 GMJK250T5G-1 GMJK250T5N-1 GMJK250T5NG-1 WEIGHT 1.8 kg
229mm
Page 4.8 | www.StarlinePower.com
Sta
nd
ard
GM
40
0T5
, G
M4
00
T5N
, G
M4
00
T5G
, G
M4
00
T5N
G,
Am
p S
yste
m,
41
5 V
olts
3 o
r 4
pol
e w
ith
/w
ith
out
Isol
ated
gro
un
d
Pow
er F
eed
p
age
5.5
-5.6
Hou
sin
g S
ecti
on
pag
e 5
.2
Inst
alla
tion
Too
l p
age
5.8
Su
pp
ort
Har
dw
are
pag
e 5
.7
End
Cap
p
age
5.7
Tee
pag
e 5
.4
Cou
ple
r
pag
e 5
.7
Elb
ow p
age
5.3
Plu
g-I
n U
nit
s 7
.7-7
.10
Bu
s C
onn
ecto
r p
age
5.8
145m
m
128
mm
12
8mm
145m
m
GM
400T
5NG
, 400
Am
p Sy
stem
, 415
Vol
t (O
VE
RSI
ZE
D N
EU
TR
AL
&
ISO
LAT
ED
GR
OU
ND
)
Page 5.1 | www.StarlinePower.com Acc
esso
ries
– C
losu
re S
trip
5.7
GM
400T
5 G
M40
0T5N
G
Protective Earth Options
Page 5.1b l www.StarlinePower.com
FAQ CHASSIS EARTH, DEDICATED EARTH, ISOLATED EARTH
CHASSIS EARTH Uses aluminium housing as 100% rated earth path, and no extra copper bar.
ISOLATED EARTH 6hr receptacles position in plugs. Chassis earth isolated from copper earth bar. Isolated earth carried back to panel by others.
DEDICATED EARTH Extra bar in busway for earth. Everything tied together inside plugs. Chassis and dedicated earth bar at same potential.
GM100 GM225
T5
GM100G
T5G
GM100G
T5G
Catalog Number Sequence GM400T5–(X)PG–(L)
Length
3 or 4.5 Metres or custom length No. of Poles System size = 400 Amps G – isolated PE NG – ISO PE & 200% Neutral
Catalog Number Selection
Catalog No. Description Length Weight
GM400T5-4PG-3-415 GM400T5-4PG-4.5-415 GM400T5G-4PG-3-415 GM400T5G-4PG-4.5-415 GM400T5N-4PG-3-415 GM400T5N-4PG-4.5-415 GM400T5NG-4PG-3-415 GM400T5NG-4PG-4.5-415
400A, 4-pole 400A, 4-pole 400A, 4P/iso. PE 400A, 4P/iso. PE 400A, 4P/ 200%N 400A, 4P/ 200%N 400A, 4P/ISO PE/200%N 400A, 4P/ISO PE/200%N
3 m 4.5 m 3 m 4.5 m 3 m 4.5 m 3 m 4.5 m
43 kg 64.5 kg 45 kg 68 kg 50 kg 75 kg 54 kg 81.5 kg
Track Busway housing sections consist of an extruded aluminium shell with “spring-pressure” type copper channel busbars contained in a full length Halogen Free insulator mounted on the interior walls. The aluminium extrusion acts as a 100% protective earth meeting IEC 60439-2. Each housing has a continuous access slot over its entire length for the insertion of turn-n-lock plug-in units. The plug-in opening features finger safety to IP2X. Housing configurations include 3 or 4-pole varieties 220…415V, optional isolated protective earth, optional oversize neutral. The housing sections join together using Bus Connectors, which fit into the channels of the adjoining section. An Installation Tool is used to force the blades into the busbar channels for a solid “spring-pressure” electrical connection. MATERIAL: Extruded Aluminium RATINGS: 100% Protective
Earth 400 Amps
GM400T5/GM400T5G 415 Volt GM400T5N/ GM400T5NG 415 Volt
LENGTH: 3 or 4.5 metres VOLTAGE DROP: Distributed load, .8PF Single Phase 14.9m
per volt Three Phase 17.6m
per volt
HOUSING SECTION
GM400T5, GM400T5N, GM400T5G, GM400T5NG System
Systems
145mm
(L2)
(L1) (N)
(L3)
ISO PE
128mm
spring pressure spring pressure
“Spring-pressure” channel busbar US Pat. # 6,039,584
Housing sections are joined by inserting the Bus Connector, which fits into the channels of the adjoining section. The Installation Tool is then rotated to force blades into slots.
Tool Force
Page 5.2 | www.StarlinePower.com
Catalog Number Sequence GMELT5400T5-(P)–(X) Direction Right, Left
Number of Poles
System size = 400 Amps G – Isolated PE NG –ISO PE & 200% Neutral
Elbow
Catalog Number Selection
Catalog No. Description Weight GMEL400T5-4-L-415 GMEL400T5-4-R-415 GMEL400T5G-4-L-415 GMEL400T5G-4-R-415 GMEL400T5N-4-L-415 GMEL400T5N-4-R-415 GMEL400T5NG-4-L-415 GMEL400T5NG-4-R-415
Elbow, 4-pole, left Elbow, 4-pole, right Elbow, 4-pole/ISO PE, left Elbow, 4-pole/ISO PE, right Elbow, 4-pole/200% N, left Elbow, 4-pole/200% N, right Elbow, 4-pole/ISO PE/200% N, left Elbow, 4-pole/ISO PE/200% N, right
12,7 kg 12,7 kg 12,7 kg 12,7 kg 12,7 kg 12,7 kg 12,7 kg 12,7 kg
Elbow Section An Elbow is used for making a horizontal 90 degree change of direction in a busway run. Specify right or left elbow, according to the orientation of the polarizing stripe in the busway sections to be connected. Plug-in unit cannot be inserted in elbow section open channel. CONNECTION ACCESSORIES: (Ordered Separately) Joint Kit (GMJK400 series) is used to make mechanical and electrical connections to adjacent busway sections.
ELBOW SECTION
Internal Elbow External Elbow
Horizontal Elbow
Installed with couplers
GMEL400-4-L
GMEL400-4-R
GM400T5, GM400T5N, GM400T5G, GM400T5NG Systems
Page 5.3 | www.StarlinePower.com
Catalog Number Sequence GMT400T5-(P)–(X) Direction External or Internal Right or Left
Number of Poles
System size = 400 Amps G – isolated PE NG –ISO PE & 200% Neutral
Tee
Catalog Number Selection (standard GM400 shown)
Catalog No. Description Weight
GMT400T5-4-IL-415 GMT400T5-4-EL-415 GMT400T5-4-IR-415 GMT400T5-4-ER-415
Tee, 4-pole, Internal Left Tee, 4-pole, External Left Tee, 4-pole, Internal Right Tee, 4-pole, External Right
19,0 kg 19,0 kg 19,0 kg 19,0 kg
Elbow Section A tee is used for making a horizontal 90 degree branch leg in a busway run. Specify internal, external, right, or left tee, according to the orientation of the polarizing stripe in the busway sections to be connected. Plug-in unit cannot be inserted in tee section open channel. CONNECTION ACCESSORIES: (Ordered Separately) A Joint Kit (GMJK400 series) is used to make mechanical and electrical connections to adjacent busway sections.
TEE SECTION
GM400T5, GM400T5N, GM400T5G, GM400T5NG Systems
External Left -EL
Internal Right -IR
Internal Left -IL
762mm
External Right -ER
457mm
Polarizing Stripe
Page 5.4 | www.StarlinePower.com
Catalog Number Sequence DS400T5G–400-4-415 System Volts
System Poles System size = 400 G – isolated PE NG – ISO PE & 200% Neutral
Disconnect Switch
Catalog Number Selection
Catalog No. Description Weight
DS400T5G-400-4-415
IN-LINE SWITCH 4 POLE
27.5 kg
Disconnect Switch Power Feed Units Standard Non-Fused Disconnect Switch Power Feed units supply power from the underside of the Busway. Busway circuit protection is provided upstream by third party switchgear. Factory assembled unit consists of a 565mm X 361mm X 205mm steel junction box, with screw mounted steel cover. Assembled disconnect switch unit is mounted underneath of a 914mm section of Busway. Disconnect Switch End Feed Power units can be positioned at end of a busway run. Connections to adjoining busway sections are made by the standard means, requiring couplers and bus connectors, which are sold separately. 400amp, 415V, 35kA
Disconnect Switch Power Feed Supply Power via Disconnect Switch to Busway Run
914mm
361mm
565mm
205mm
GM400T5, GM400T5N, GM400T5G, GM400NG Systems
Page 5.5a | www.StarlinePower.com
Catalog Number Sequence GMEF400T5–(P)(R) Reverse
System Poles System size = 400 Amps G – isolated PE NG – ISO PE & 150% Neutral DG – Dedicated Earth
End Feed
Catalog Number Selection
Catalog No. Description Weight
GMEF400T5-4-415 GMEF400T5-4R-415 GMEF400T5G-4-415 GMEF400T5G-4R-415 GMEF400T5N-4-415 GMEF400T5N-4R-415 GMEF400T5NG-4-415 GMEF400T5NG-4R-415
End Feed, 4-Pole End Feed, 4-Pole End Feed, 4-Pole/ISO PE End Feed, 4-Pole/ISO PE End Feed, 4-Pole/200% N End Feed, 4-Pole/200% N End Feed, 4-Pole/ISO PE/200% N End Feed, 4-Pole/ISO PE/200% N
14,3 kg 14,3 kg 14,5 kg 14,5 kg 15,0 kg 15,0 kg 15,2 kg 15,2 kg
Standard End Power Feed units connect to the end of any busway section. Factory assembled units consist of a 305mm X 432mm X 254mm steel junction box, with removable sides, connected to a 305mm section of busway. The assembly includes connection lugs for wires up to 300mm2. Chassis earth and isolated earth allow wires up to 185 mm2 and 152 mm2 respectively. Reverse end feed units for connection to opposite end of busway section (polarizing stripe faces to right as viewed from end of unit). Junction box is sized such that one or two 103mm conduits can be installed in end of box. End Power Feed units are connected to adjacent busway sections using Housing Coupler and Bus Connector (sold separately). Special need Power Feed Units for confined spaces found in Mission Critical Data Centers can also be designed and fabricated, requiring minimum quantities. Reference page 5.1b for dedicated ground application. Contact UEC representative for further information.
END POWER FEED UNITS Supplying Power to End of Busway
GM400T5, GM400T5N, GM400T5G, GM400T5NG Systems
Standard
Reversed
Assembled with 305mm of Busway
As shown on layout dwg
Page 5.5b | www.StarlinePower.com
Catalog Number Sequence GMTF400T5–(P)-415
System Poles System size = 400 Amps G – isolated PE NG – ISO PE & 200% Neutral
Top Feed
Catalog Number Selection
Catalog No. Description Weight
GMTF400T5-4-415 GMTF400T5-4R-415 GMTF400T5G-4-415 GMTF400T5G-4R-415 GMTF400T5N-4-415 GMTF400T5N-4R-415 GMTF400T5NG-4-415 GMTF400T5NG-4R-415
Top Feed, 4-Pole Top Feed, 4-Pole Top Feed, 4-Pole/ISO PE Top Feed, 4-Pole/ISO PE Top Feed, 4-Pole/200% N Top Feed, 4-Pole/200% N Top Feed, 4-Pole/ISO PE/200% N Top Feed, 4-Pole/ISO PE/200% N
21 kg 21 kg 21 kg 21 kg
23,6 kg 23,6 kg 23,6 kg 23,6 kg
Top Power Feed Units Standard Top Power Feed units supply power from the topside of the Busway. Factory assembled unit consists of a 508mm X 305mm X 203mm steel junction box, with hinged cover, mounted on top of a 914mm section of Busway. Top Feed Power units can be positioned at end or anywhere along a busway run. Connections to adjoining busway sections are made by the standard means, requiring couplers and bus connectors, which are sold separately. Top Feed unit can also be used as top power supply point anywhere along Busway run by connecting to adjacent Busway sections at both ends.
TOP POWER FEED Supplying Power to TOP of Busway
914mm Busway Section
305mm 508mm
203mm
Standard (R) Reversed
Hinged side
Hinged side
GM400T5, GM400T5N, GM400T5G, GM400T5NG Systems
Page 5.6 | www.StarlinePower.com
OPTIONAL CLOSURE STRIP (Aluminium/PVC) Snaps into bottom access slot of GM400T5 housing sections. Normally shipped in 3m lengths.
END CAP For covering the end of GM400T5 busway run.
CONNECTION ACCESSORIES
GM400T5, GM400T5N, GM400T5G, GM400T5NG Systems
PART NUMBER GMEC400T5 Weight 0,18 kg
145mm
107mm
HANGER BOLTS Threaded Rod (GMBRH400T5-M12) For mounting to M12 threaded rod. Twist-in design. Can be inserted anywhere along the full access slot on the top of the busway. Maximum hanger support spacing is every 3m. Standard (GMBH400T5-12) For mounting to strut or other flat surfaces. Twist-in design. Can be inserted anywhere along the full access slot on the top of the Busway. Maximum hanger support spacing is every 3m.
PART NUMBER GMBRH400T5-M12 GMBH400T5-M12 Weight 0,45 kg
PART NUMBER GMCST5-AL GMCST5-1 Weight 0,67 kg/m 0,44 kg/m
GMBRH400T5-M12
GMBH400T5-M12
Page 5.7 | www.StarlinePower.com
INSTALLATION TOOL
GM400T5, GM400T5N, GM400T5G, GM400T5NG Systems
Accessories
Used to install the ‘bus connector’ electrical joint between two adjacent sections of Busway. A ‘Joint Kit’, comprised of two housing couplers and a bus connector set are required at every joint.
Busway sections are butted together and the top housing coupler is installed. The Bus connector is inserted, centered and seated in the slot of the Busway. The installation tool is inserted into jointed intersection and rotated 90º forcing stabs into u-shaped female conductors making a spring-loaded, secure electrical connection. Housing Coupler is positioned over the bottom joint and tightened.
For Standard T5 Series PART NUMBER Installation Tool GMT5IT
Weight 1.40 Kgs.
Busway Section
Tool Pressure
Busway section
JOINT KIT For connection of adjacent Busway sections. One Kit required at each joint. Each Kit is comprised of a housing coupler pair and bus connector set. Specify configuration to match busway configuration.
HOUSING COUPLER:
Consists of two, 12-screw couplers- one for the top and one for the bottom.
BUS CONNECTOR: Copper blades secured to insulating mounting plate. Left and Right set, makes electrical connection between sections.
Part Number
GMJK400T5-1 GMJK400T5G-1 GMJK400T5N-1 GMJK400T5NG-1
WEIGHT
1.81 Kgs.
228.6
Page 5.8 | www.StarlinePower.com
Sta
nd
ard
GM
80
0T5
, G
M8
00
T5G
,
80
0 A
mp
Sys
tem
, 4
15
Vol
ts
Pow
er F
eed
p
age
6.5
Hou
sin
g S
ecti
on
pag
e 6
.2-6
.3
Inst
alla
tion
Too
l p
age
6.8
Su
pp
ort
Har
dw
are
pag
e 6
.6
End
Cap
p
age
6.6
Cou
ple
r
pag
e 6
.8
Elb
ow
pag
e 6
.4
Plu
g-I
n U
nit
s
pag
e 7
.7-7
.10
Acc
esso
ries
– A
cces
s S
hu
tter
, C
losu
re S
trip
,Wei
gh
t H
ook
Bu
s C
onn
ecto
r
pag
e 6
.8
B80
0T5G
CA
, 800
Am
p Sy
stem
, 600
Vol
t w
/ Iso
late
d G
roun
d
163
mm
128
mm
Page 6.1 | www.StarlinePower.com
Protective Earth Options
Page 6.1b l www.StarlinePower.com
FAQ CHASSIS EARTH, DEDICATED EARTH, ISOLATED EARTH
CHASSIS EARTH Uses aluminium housing as 100% rated earth path, and no extra copper bar.
ISOLATED EARTH 6hr receptacles position in plugs. Chassis earth isolated from copper earth bar. Isolated earth carried back to panel by others.
DEDICATED EARTH Extra bar in busway for earth. Everything tied together inside plugs. Chassis and dedicated earth bar at same potential.
GM100 GM225
T5
GM100G
T5G
GM100G
T5G
Page 6.2 | www.StarlinePower.com
Catalog Number Sequence GM800T5CA(G)(S)–(X)PG–(L)
1.5 or 3 or Custom Length
No. of Poles
Access Shutter Length
1.5 or 3 or Custom Length System Size=800Amps /CuAL
G – Isolated PE
163mm
128 mm
Track Busway housing section consists of an extruded aluminium shell with a composite copper-aluminum “spring-pressure” busbar channels contained in a full length halogen free insulator mounted on the interior walls. The enclosure provides a 100% ground path meeting IEC 60439-2 Standard and Section 250 of the NEC. Continuous Plug-In version has a continuous access slot over its entire length for the insertion of turn-n-lock plug-in units. Plug-In Versions designated type ‘S” provide access shutters on 254 (mm) centers its entire length for the insertion of plug-in units. Housing configurations include 3 or 4 pole varieties 220…415V, optional isolated ground. The housing sections join together using Bus connectors, which fit into the channels of the adjoining section for a solid “spring- pressure” electrical connection. MATERIAL: Extruded Aluminium CONDUCTOR: Composite Cu/Al RATINGS: 100% Protective
Earth (IEC 60439-2) 800 Amps
415 Volt LENGTH: 1.5 mtrs, 3 mtrs.
HOUSING SECTIONS
GM800T5CA, GM800T5CAG Systems
Catalog Number Selection
Catalog No. Description Length/ Weight
GM800T5CA-4PG-1.5-415 GM800T5CA-4PG-3 -415 GM800T5CAG-4PG-1.5-415 1.5mtrs 28.5kgs GM800T5CAG-4PG-3-415 GM800T5CAS-4PG-1.5-415 1.5mtrs 26.3kgs GM800T5CAS-4PG-3-415 GM800T5CAGS-4PG-1.5-415 GM800T5CAGS-4PG-3-415
800A, Continuous Access 4P 800A, Continuous Access 4P 800A, Continuous Access 4P/ISO PE 1.5mtrs 28.5kgs 800A, Continuous Access 4P/ISO PE 3mtrs 57kgs 800A, Shutter Access 4P 1.5mtrs 26.3kgs 800A, Shutter Access 4P 52.1kgs 800A, Shutter Access 4P/ISO PE 800A, Shutter Access 4P/ISO PE *Shutter varies depending on plug-in type/model
1.5mtr,24kg 3mtr,47.6kg 1.5mtr,28.5kg 3mtr,57kgs 1.5mtr,26.3kg 3mtr,52.1kg 1.5mtr,30.8kg 3mtr,61.6kg
HOUSING SECTIONS
Track Busway housing section consists of an extruded aluminium shell with copper “spring-pressure” busbar channels contained in a full length halogen free insulator mounted on the interior walls. The enclosure provides a 100% ground path meeting IEC 60439-2 Standard and Section 250 of the NEC. Continuous Plug- In version has a continuous access slot over its entire length for the insertion of turn-n-lock plug-in units. Plug-In Versions designated type ‘S” provide access shutters on 254 (mm) centers its entire length for the insertion of plug-in units. Housing configurations include 3 or 4 pole varieties 220…415V, optional isolated ground. The housing sections join together using Bus Connectors which fit into the channels of the adjoining section for a solid “spring- pressure” electrical connection. MATERIAL: Extruded Aluminium CONDUCTOR: Copper RATINGS: 100% Protective Earth
(IEC 60439-2) 800 Amps 415 Volt
LENGTH: 1.5 Mtrs, 3 mtrs.
Catalog Number Sequence GM800T5CC(G)(S)–(X)PG–(L)-415
1.5 or 3 or Custom Length
No. of Poles System Size = 800/CU G – Isolated PE
Page 6.3 | www.StarlinePower.com
GM800T5CC, GM800T5CCG, GM800T5CCS, GM800T5CCGS Systems
Catalog Number Selection
Catalog No. Description Length/ Weight
GM800T5CCG-4PG-1.5-415 1.5mtrs 45.3kgs GM800T5CCG-4PG-3-415 GM800T5CCS-4PG-1.5-415 1.5mtrs 44.5Kgs GM800T5CCS-4PG-3-415 3mtrs 89Kgs GM800T5CCGS-4PG-5-415 GM800T5CCGS-4PG-10-415 GM800T5CCGS-4PG-5-415 GM800T5CCGS-4PG-10-415
800A, Continuous Access 4P 800A, Continuous Access 4P 800A, Continuous Access 4P/ISO PE 800A, Continuous Access 4P/ISO PE 800A, Shutter Access 4P 800A, Shutter Access 4P 800A, Shutter Access 4P/ISO PE 800A, Shutter Access 4P/ISO PE *Shutter varies depending on plug-in type/modle.
1.5mtr,43kg 3mtr,86Kg 1.5mtr,45.3kg 3mtr,90.7kg 1.5mtr,44.5kg 3mtr,89kg 1.5mtr,46.7kg 3mtr,92.8kg
HORIZONTAL ELBOW SECTIONS
Catalog Number Selection Catalog No. Description Weight GMEL800T5-4-L-415 Elbow, 4-pole, left 12.7 Kgs GMEL800T5-4-R-415 Elbow, 4-pole, right 12.7 Kgs GMEL800T5G-4-L-415 Elbow, 4-pole/ISO PE, left 13.6 Kgs GMEL800T5G-4-R-415 Elbow, 4-pole/ISO PE, right 13.6 Kgs
Elbow Section An Elbow is used for making a horizontal 90 degree change of direction in a Busway run. Specify right or left elbow, according to the orientation of the polarizing stripe in the Busway sections to be connected. Suitable for both CA and CC type busway. Plug-in unit cannot be inserted in elbow section open channel. CONNECTION ACCESSORIES: (Ordered Separately) Joint Kit (GMJK800 series) is used to make mechanical and electrical connections to adjacent Busway sections.
Catalog Number Sequence GMEL800-(P)–(X) Direction Right, Left
Number of Poles
System size = 800 Amps G – Isolated PE Elbow
GMEL800T5-4-L Internal Elbow
GMEL800T5-4-R External Elbow
GM800T5 Systems
457.2
457.2
Page 6.4 | www.StarlinePower.com
END POWER FEED UNITS
Catalog Number Selection Catalog No. Description Weight GMEF800T5-4-415 End Feed, 4-Pole 14.2 Kgs GMEF800T5-4R-415 End Feed, 4-Pole / Rev 14.2 Kgs GMEF800T5G-4-415 End Feed, 4-Pole / ISO PE 14.5 Kgs GMEF800T5G-4R-415 End Feed, 4-Pole / ISO / Rev 14.5 Kgs
Supplying power to end of Busway Standard End Power Feed units connect to the end of any busway section. Factory assembled unit consists of a 610 X 508 X 508 mm. steel junction box, with removable sides, connected to a 305mm section of busway. The assembly includes connection lugs that can handle up to (2) 300mm2 wires (CU) or (3) 300mm2 wires (AL). Chassis earth and isolated earth allow wires up to 185mm2. Reverse End feed units for connection to opposite end of busway section (polarizing stripe faces to right as viewed from end of unit). Junction box is sized such that one or two 100mm conduits can be installed in end of box. End Power Feed units are connected to adjacent Busway sections using Housing Coupler and bus connector (sold separately). Special need power feed units for confined spaces as might be found in Mission Critical Data Centers can also be designed and fabricated, requiring minimum quantities. Reference page 6.1b for dedicated earth application. Contact UEC representative for further information.
Catalog Number Sequence GMEF800T5–(P)(R) Reverse
System Poles
System size = 800 amp G – Isolated Ground DG – Dedicated Ground
End Feed
GM800T5 Series Systems
508
508
610
305mm SECTION OF BUSWAY
Page 6.5 | www.StarlinePower.com
CENTER POWER FEED UNITS
Catalog Number Selection Catalog No. Description Weight GMCF800T5-4-415 Ctr Feed, 4-Pole 14.2 Kgs GMCF800T5G-4-415 Ctr Feed, 4-Pole/ISO PE 14.5 Kgs
Supplying power to center of Busway Center Power Feed unit connects between adjacent busway sections to provide power in the center of a busway run. Factory assembled unit consists of a 610 X 508 X 762mm. steel junction box, with removable sides, connected to two 305 mm sections of busway. The assembly includes connection lugs that can handle up to (2) 300mm2 MCM wires (CU) or (3) 300mm2 wires (AL). Chassis earth and isolated earth allow wires up to 185mm2. Junction box is sized such that one or two 100mm conduits can be installed in end of box. Center Power Feed units are connected to adjacent Busway sections using Housing Coupler and bus connector (sold separately). Special need power feed units for confined spaces as might be found in Mission Critical Data Centers can also be designed and fabricated, requiring minimum quantities.
Catalog Number Sequence GMCF800T5(X)–(P) System Poles
System size = 800 amps G – ISO Protective Earth
Center Feed
GM800T5 Series Systems
762mm
610mm 508mm
1220mm
POLARIZED STRIPE
Page 6.6 | www.StarlinePower.com
CONNECTION ACCESSORIES
END CAP For covering the end of GM800T5 Busway run.
GM800T5 Systems
PART NUMBER GMEC800T5 WEIGHT 0.181 Kgs.
PART NUMBER GMBRHT5-M12 GMBHT5-M12 WEIGHT .453 Kgs.
OPTIONAL CLOSURE STRIP (Aluminium/PVC) Snaps into bottom access slot of GM800T5 housing sections. Normally shipped in 3 meters lengths.
PART NUMBER GMCST5-AL GMCST5-1 WEIGHT 0.67 kg/m 0.44 kg/m
HANGER BOLTS
Threaded Rod (GMBRHT5-M12)
For mounting to M12 threaded rod. Twist-in design. Can be inserted anywhere along the full access slot on the top of the Busway. Maximum hanger support spacing is every 3 meters. Standard (GMBHT5-M12)
For mounting to strut or other flat surfaces. Twist-in design. Can be inserted anywhere along the full access slot on the top of the Busway. Maximum hanger support spacing is every 3 meters.
BRHT5-1
BHT5-1
Page 6.7 | www.StarlinePower.com
INSTALLATION TOOL
INSTALLATION TOOL Used to install the ‘bus connector’ electrical joint between two adjacent sections of Busway. A ‘Joint Kit’, comprised of two housing couplers and a bus connector set are required at every joint. Busway sections are butted together and the top housing coupler is installed. The Bus connector is inserted, centered and seated in the slot of the Busway. The installation tool is inserted into jointed intersection and rotated 90º forcing stabs into u-shaped female conductors making a spring-loaded, secure electrical connection. Housing Coupler is positioned over the bottom joint and tightened.
JOINT KIT/INSTALLATION TOOL
PART NUMBER Installation Tool GMT5IT For T5 Series Weight 1.40 Kgs.
GM800T5 Systems Systems
PART NUMBER GMJK800T5-1 GMJK800T5G-1 WEIGHT 1.81 Kgs.
Page 6.8 | www.StarlinePower.com
JOINT KIT For connection of adjacent Busway sections. One Kit required at each joint. Each Kit is comprised of a housing coupler pair and bus connector set. Specify configuration to match busway configuration. HOUSING COUPLER: Consists of two, 12-screw couplers- one for the top and one for the bottom. BUS CONNECTOR: Silver plated copper blades secured to insulating mounting plate. Left and Right set, makes electrical connection between sections.
E28 Circuit Breaker Unit Page 7.2
E28 Socket Units Page 7.3
E28 Drop Cord Units Page 7.4
E25 Socket Units Page 7.5
E25 Hybrid Units Page 7.6 E40 Circuit Breaker Drop Cord Page 7.7
E40 Circuit Breaker Page 7.8 E40 Circuit Breaker Socket Page 7.9 E50 Circuit Breaker Drop Cord Page 7.10 E70 Circuit Breaker Page 7.11 E90 Circuit Breaker Page 7.12 Monitoring Page 8.1
PLUG-IN UNITS Table of Contents
GM100/GM100G/GM100NG/GM225/ GM400/GM400G/GM400N/GM400NG/GM800
Page 7.1 | www.StarlinePower.com
Basic MCB unit used to tap off power from the busway. Plug head is reversible to face in opposite direction. • Capable to 7 MCB pole
positions. • MCB’s are factory installed to
internal DIN rail. • D-curve MCBs supplied unless
trip curve is specified.
• Consult factory for possible combinations.
• Maximum ratings of 100 total
amps, 220…415V, 50…60 Hz, 10K Ipk (Higher Ipk upon request).
• IP3X • Requires 235mm slot space
• Locks into position with a single
bolt on mounting tab.
E28 CIRCUIT BREAKER PLUG-IN
100, 225, 400 Amp GM100, GM100G, GM100NG, GM225,
GMT5, GMT5G, GMT5N, GMT5NG
Catalog Number Sequence GMCB***E28-aa-y-xxx
Voltage
Circuit breaker(s), and (p/aa-y)
Enclosure
System Size, 100, 100G, 100NG, 225,
GMT5, GMT5G, GMT5N, GMT5NG
Circuit Breaker
Single MCB aa=amps 16-63 y=MCB poles, 1-4
Multiple MCB’s p=MCB poles, 1-4 aa=amps 16-63 y=total poles, 1-7
Normal position, breaker faces busway conductor side
Enclosure conductor stab assembly can be rotated (in the field) to face opposite side.
GMT5 Series plug-head
Page 7.2 | www.StarlinePower.com
100/225 Plughead
Catalog Number Sequence GMCB***E28-(SOCKET)
Wiring Device, ref. via IEC page 9.6
Enclosure
System Size, 100,100G,100NG, 225,
GMT5, GMT5G, GMT5N, GMT5NG
Circuit Breaker
MCB unit with sockets or receptacles, used to tap off power from the Busway with a wide variety of device configurations. Units are shipped fully assembled. Plug head is reversible to face in opposite direction.
• Capable to 7 MCB pole positions.
• Capable to 2 or more sockets.
(Consult factory for possible combinations.)
• D-curve MCBs supplied unless
trip curve is specified • Maximum ratings of 100 total
amps, 220…415V, 50…60 Hz, 10K Ipk (Higher Ipk upon request)
• IP3X • Requires 235mm slot space.
• Locks into position with a single
bolt on mounting tab.
E28 CIRCUIT BREAKER SOCKET PLUG-IN
100, 225 T5 Series Amp GM100, GM100G, GM100NG, GM225,
GMT5, GMT5G, GMT5N, GMT5NG
Normal position, breaker faces busway conductor side
Enclosure conductor stab assembly can be rotated (in the field) to face opposite side.
Page 7.3 | www.StarlinePower.com
Catalog Number Sequence GMCBDC***E28-X-(CONNECTOR)
Wiring Device
Cord Length in meters
Enclosure
System Size, 100,100G,100NG, 225,
GMT5, GMT5G, GMT5N, GMT5NG
Circuit Breaker/Drop Cord
MCB unit with drop cords used to tap off power from the busway with a wide variety of device configurations. Units are shipped fully-assembled. Plug head is reversible to face in opposite direction.
• Capable to 7 MCB pole positions.
• Capable to 3 drop cords.
Consult factory for possible combinations and cord lengths
• D-curve MCBs supplied unless
trip curve is specified. • Maximum ratings of 100 total
amps, 220…415V, 50…60Hz, 10K Ipk (Higher Ipk upon request).
• IP3X
• Requires 235mm slot space.
• Locks into position with a single
bolt on mounting tab.
E28 CIRCUIT BREAKER DROP CORD PLUG-IN
100, 225, T5 Series Amp GM100, GM100G, GM100NG, GM225,
GMT5, GMT5G, GMT5N, GMT5NG
Normal position, breaker faces busway conductor side
Enclosure conductor stab assembly can be rotated (in the field) to face opposite side.
Page 7.4 | www.StarlinePower.com
Catalog Number Sequence GMCB(sys)E25-(socket)
Socket Configuration Ref. page 9.6
System Size
100, 100G, 100NG, 225, 225G Circuit Breaker
Catalog Number Selection
Catalog No. Description Weight
GMCB225E25-(2)W26424-(2)332A6S (2)32A/3wire/230V Socket w/ 1P MCB & (2)W26424
5,44 kg
GMCB225E25-(3)332A6S/2P (3) 32A/3wire/230V Sockets, (3)2P MCB’s
5,44 kg
GMCB400E25-(2)532A6S-4 (2) 32A/5wire/415V, Sockets, (2)3P MCB’s
5,44 kg
Versatile MCB unit with sockets or receptacles, used to tap off power from the busway with a wide variety of device configurations. Units are shipped fully assembled. Plug head is reversible to face in opposite direction.
• Capable to 8 MCB pole positions.
• Capable to 3 or more sockets.
(Consult factory for possible combinations.)
• D-curve MCBs supplied unless
trip curve is specified • Maximum ratings of 100 total
amps, 220…415V, 50…60 Hz, 10K Ipk (Higher Ipk upon request).
• IP3X • Requires 450mm slot space. • Locks into position with two
bolts.
E25 CIRCUIT BREAKER PLUG-IN
100, 225, T5 Series Amp GM100, GM100G, GM100NG, GM225,
GMT5, GMT5G, GMT5N, GMT5NG
Page 7.5 | www.StarlinePower.com
Versatile MCB unit can be customized by factory with sockets or receptacles, and drop cords. A wide variety of device combinations are possible. Units are shipped fully assembled. Plug head is reversible to face in opposite direction.
• Capable to 8 MCB pole positions.
• Capable to 3 or more sockets
and up to 3 drop cords. (Consult factory for possible combinations.)
• D-curve MCBs supplied unless
trip curve is specified. • Maximum ratings of 100 total
amps, 220…415V, 50…60 Hz, 10K Ipk (Higher Ipk upon request).
• IP3X • Requires 450 mm slot space. • Locks into position with two
bolts. Consult factory to specify devices, configuration and ordering information.
E25 HYBRID PLUG-IN
100, 225, T5 Series Amp GM100, GM100G, GM100NG, GM225,
GMT5, GMT5G, GMT5N, GMT5NG
Page 7.6 | www.StarlinePower.com
Catalog Number Sequence GMCBDCT5E28-X-(CONNECTOR)
Wiring Device
Cord Length in metres
Enclosure
System Size: T5. Add ‘G’ or ‘NG’ as required
Circuit Breaker/Drop Cord
Premium engineered MCB unit with drop cords used to tap off power from the busway with a wide variety of device configurations. Units are shipped fully-assembled. Plug head is reversible to face in opposite direction. Compatible with all ‘T5’ busway systems.
• Provides multiple MCB pole positions by adjusting unit length.
• Capable to 3 or more drop
cords. Consult factory for possible combinations and cord lengths
• D-curve MCBs supplied unless
trip curve is specified. • Maximum ratings of 125 total
amps, 220…415V, 50…60Hz, 10K Ipk (Higher Ipk upon request).
• IP3X
• Locks into position with a single
bolt on mounting tab.
E40 CIRCUIT BREAKER DROP CORD PLUG-IN
T5 System Plugs
Normal position, breaker faces busway conductor side
Enclosure conductor stab assembly can be rotated (in the field) to face opposite side.
Page 7.7 | www.StarlinePower.com
178
127
Premium engineered unit that combines style with versatility. Designed to tap off power from the busway. Compatible with all ‘T5’ busway systems. Plug head is reversible to face in opposite direction. • Provides multiple MCB pole
positions by adjusting unit length.
• MCB’s are factory installed to
internal DIN rail. • D-curve MCBs supplied unless
trip curve is specified.
• Consult factory for possible combinations.
• Maximum ratings of 125 total
amps, 220…415V, 50…60 Hz, 10K Ipk (Higher Ipk upon request).
• IP3X • Locks into position with a single
bolt on mounting tab.
E40 CIRCUIT BREAKER PLUG-IN
T5 System Plugs
Catalog Number Sequence GMCBT5E48-aa-y-xxx
Voltage
Circuit breaker(s), and (p/aa-y)
Enclosure
System Size: T5. Add ‘G’ or ‘NG’ as required
Circuit Breaker
Single MCB aa=amps 16-63 y=MCB poles, 1-4
Multiple MCB’s p=MCB poles, 1-4 aa=amps 16-63 y=total poles, 1-7
GMT5 Series plug-head
Normal position, breaker faces busway conductor side
Enclosure conductor stab assembly can be rotated (in the field) to face opposite side.
356
Page 7.8 | www.StarlinePower.com
356
178
Catalog Number Sequence GMCBT5E40-(SOCKET)
Wiring Device, ref. page 9.6
Enclosure
System Size: T5 or T5G
Circuit Breaker
Premium engineered MCB unit with sockets or receptacles, used to tap off power from the Busway with a wide variety of device configurations. Units are shipped fully assembled. Plug head is reversible to face in opposite direction. Compatible with all ‘T5’ busway systems.
• Provides multiple MCB pole positions by adjusting unit length.
• Capable to 2 or more sockets.
(Consult factory for possible combinations.)
• D-curve MCBs supplied unless
trip curve is specified • Maximum ratings of 125 total
amps, 220…415V, 50…60 Hz, 10K Ipk (Higher Ipk upon request)
• IP3X • Locks into position with a single
bolt on mounting tab.
E40 CIRCUIT BREAKER SOCKET PLUG-IN
T5 System Plugs
Normal position, breaker faces busway conductor side
Enclosure conductor stab assembly can be rotated (in the field) to face opposite side.
Page 7.9 | www.StarlinePower.com
Page 7.10 | www.StarlinePower.com
Latching Mechanism (No tooling install)
T5 Series Plug-Ins GM250T5, GM400T5, GM800T5
SYSTEMS E50 ENCLOSURE
Circuit Breaker Applications Next-generation, custom engineered enclosure that features a stylish exterior combined with a spacious interior and customizable body length to accommodate a wide variety of applications. The E50-Series enclosure is designed to tap off power from the busway and is compatible with all “T5” systems. The option is available to have a reverse T5 Paddle such that the enclosure faces in the opposite direction when in the busway. • Configurable unit length for
multiple circuit breaker pole positions.
• Locks easily and quickly into
position using a “no tooling” latching mechanism
• Maximum rating of 35kA at
480V • Consult factory for possible
combinations*
Catalog Number Sequence
GM CB [DC] T5 (G) (H) E 5 x – [L] - (X)(Wiring Device)
Global Metric
(Circuit Breaker)
(Drop Cord)
Isolated Earth
High-Interrupt
Rating Length of Drop Cord (Meters)
Enclosure* 1 through 7
Model Shown: GMCBT5GE56-(4)332A6S/2P
T5 Paddle (Standard Orientation,
Reverse option available)
Enclosure Lengths (Please consult factory
for proper sizing)
E51 – 156mm (6.14”) E52 – 207mm (8.14”) E53 – 258mm (10.14”) E54 – 309mm (12.14”) E55 – 334mm (13.14”) E56 – 386mm (15.14”) E57 – 461mm (18.14”)
e.g IEC309 Single/Three Phase Device Amps Angled / Straight Receptacle / Connector Splashproof /Watertight
(Device qty)
Receptacle Catalog Number Sequence GMCB(sys)E70-(SOCKET)
Socket
Configuration Enclosure
System Size 100, 225amp, T5 series. Add G as required.
Circuit Breaker
Drop Cord Catalog Number Sequence GMCBDC(sys)E70-X-(CONNECTOR)
Connector Configuration
Cord Length in meters Enclosure
System Size 100, 225amp, T5 series. Add G as required.
Circuit Breaker/Drop Cord
Premium engineered MCB unit, ideally suited where physical space is limited whilst providing high density power distribution.
Used to tap off power from the busway with a wide variety of device configurations. Units are shipped fully assembled. Plug head is reversible.
• Available for both single &
three phase.
• Available options for drop cord connector termination, surface mount receptacles or a combination of both. (Consult factory for possible combinations.)
• D-curve MCBs supplied unless
trip curve is specified.
• Maximum ratings of 125 total amps, 220…415V, 50…60 Hz, 10KA Ipk (Higher Ipk upon request).
• Metering options available. Consult factory for metering options.
• IP3X • GM225 Requires 195mm slot,
GMT5 requires 220mm width space within busway bolt.
E70 CICUIT BREAKER PLUG-IN
100, 225, T5 System Plugs
Page 7.11 | www.StarlinePower.com
Page 7.12 | www.StarlinePower.com
100, 225 Amp Plug-Ins GM100, GM225 SYSTEMS
E90 ENCLOSURE Circuit Breaker Applications
Next-generation, custom engineered enclosure that features a stylish exterior combined with a spacious interior and customizable body length to accommodate a wide variety of applications. The E90-Series enclosure is designed to tap off power from the busway. The option is available to have a reverse paddle such that the enclosure faces in the opposite direction when in the busway. • Configurable unit length for
multiple circuit breaker pole positions.
• Locks into position using a
single, easy access bolt • Maximum rating of 22kA at
480V for GM100, 22kA at 240V for GM225
• Consult factory for possible
combinations*
Catalog Number Sequence
GM CB [DC] 225 (G) (H) E 9 x – [L] – (X)(Wiring Device)
Circuit Breaker
(Drop Cord)
Isolated Earth
High-Interrupt
Rating Length of
Drop Cord (Meters)
Enclosure* 1 through 7
e.g IEC309 Single/Three Phase Device Amps Angled / Straight Receptacle / Connector Splashproof /Watertight
Model Shown: GMCB225E93-332A6S/2P-FS
225 Paddle (Standard Orientation,
Reverse option available)
Enclosure Lengths (Please consult factory
for proper sizing)
E91 – 152mm (6.00”) E92 – 203mm (8.00”) E93 – 254mm (10.00”) E94 – 305mm (12.00”) E95 – 330mm (13.00”) E96 – 381mm (15.00”) E97 – 457mm (18.00”)
Easy Access Bolt
Global Metric
(Device qty)
RECEPTACLE DESIGNATION CATALOG NUMBER SYSTEM
MONITORING
Catalog Number Selection Socket units and drop cord units GMCBDCT5E28G-X-(2)532C6W IP Type (Ingress Protection) Ground (Earth) position Connector Body First & second wiring device Number of cord sets for first wiring device Cord length metric Isolated Protective earth Enclosure (240V) T5 System Drop cord Circuit breaker protection Global Metric
GMCBT5E36-532A6S IP Type (Ingress protection) Receptacle Body Wiring device Enclosure (415V) T5 System Circuit breaker protection Global Metric
Page 8.6 | www.StarlinePower.com
Catalog No. Description
GMCB225E28-(2)316A6S-M20R16/2 CKT. BKR. UNIT W/RECEPTS – (2)316A6S
GMCBT5GE28-532A6S-M20R32/3 CKT. BKR. UNIT W/RECEPTS – 532A6S
GMCBT5GE28-332A6S-M20R32/2 CKT. BKR. UNIT W/RECEPTS – 332A6S
GMCBT5GE25-(2)520A6S-(2)M20R20/3 CKT. BKR. UNIT W/RECEPTS – (2)520A6S
GMCBDC225GE25-X-(2)516C6S-(2)M20R16/3 CKT. BKR. DROP CORD UNIT W/CONN BODY-(2)516C6S
EF400-4R-L-Mxyy400/4
CIRCUIT BREAKER UNIT FOR
BRANCH CIRCUIT MONITORING
Circuit Breaker Unit with Installed Critical Power Monitor The Branch Circuit Current Monitoring Unit has the capability of monitoring a maximum of 4 single phase receptacles or a one 3-phase receptacle. The monitor has 4 channels available. Solid core current transformers (CT) are installed around the phase wires in the plug-in unit.
‘R’ versions provide remote communication functions and ‘DR’ provide remote display and remote communications.
Communications
Ethernet and Modbus RTU ports are standard. Ethernet port provides an Embedded Web (html) Interface & supports SNMP.
See Power Monitoring pages for more details.
Page 8.5 | www.StarlinePower.com
CRITICAL POWER MONITORING M41/M43/M45/M47 DETAILS
The Starline Critical Power Monitor (CPM) is a distributed data acquisition system that enables current and power monitoring in busway systems. Each phase and neutral can be monitored independently. The CPM may be incorporated at a power feed point or directly into a plug-in unit. CURRENT TRANSFORMERS: Current transformers (CT’s) are supplied with the unit for installation onto the customer-supplied feeder cables. Sense leads from the CT’s connect to the Meter. METER MODULES: Each unit is calibrated for accuracy and is within 0.5% to meet ANSI Revenue Grade Standards. CPM– ENHANCED PACKAGE (M41/M43/M45/M47): Provides current and voltage inputs, monitoring current, voltage, power, power factor, frequency, apparent power, energy kWh, reactive power, neutral current, power min. and max. DISPLAY: The bright, 4.9” LCD reports basic power measurements and alarms. Display buttons provide configuration and direct control to the active display screen. Large format display is easily readable at a distance and wide viewing angle. COMMUNICATION: Ethernet and Modbus RTU ports are standard. Ethernet port provides an embedded web (HTTP) Interface & supports SNMP. Wi-Fi interface is optional, providing true versatility in the busway environment. ALARMS: When the defined alarm threshold is exceeded, a warning corresponding to that channel will turn ON and send an SNMP trap or an email to the user.
The Critical Power Monitor can be used to manage and maximize power distribution within a three phase power system. It can be employed as a component to help balance three phase power distribution between each phase. This increases efficiency by reducing the power factor and enables a user to fully analyze the power supplied to them.
POWER FEED MONITORING The CPM, incorporated in or near the power feed unit, provides load monitoring of the entire run of busway. These are used in conjunction with BMS systems to ensure busway is not overloaded as well as for general power management. Typically uses the CPM unit with display.
BRANCH CIRCUIT MONITORING The CPM, incorporated into a plug-in unit, monitors individual branch circuits. These units are used in conjunction with BMS system for power management and revenue purposes at the rack or circuit level. The CPM is capable of monitoring the entire unit or monitoring up to 4 individual devices, limited to 6 solid core Current Transformers (CTs).
BUILDING MANAGEMENT INTERFACE The Starline CPM is easily interfaced with BMS/BCIM systems. Many BMS/BCIM systems offer drivers for use with the Starline CPM. Contact your BMS/BCIM supplier or Starline Engineering for more information.
Critical Power Monitor with the (optional) 4.9” Display
Critical Power Monitor (No Display)
Page 8.6 l www.StarlinePower.com
1. Can you have isolated ground?
Yes – On our 100A, 225A, 250A, 400A and 800A versions we can add a fifth copper bar rated at 100% capacity ground. The product types are GM100G, GM100NG, GM225G, GM250T5G, GM400T5G, GM400T5NG and GM800T5G.
2. How do you keep people from adding too many drops and overloading the circuit?
STARLINE Track Busway is no different from any other busway or panelboard. Anyone could mount 14 - 3 pole 100A circuit breakers in a 225A main panel if they wanted to. It is typical that the addition of a circuit to STARLINE is done by a qualified person who is familiar with the electrical system at the facility. They are expected to know the load on the bus through routine sampling over time. However, for those who want protection against this issue, we have developed a product called Bus Run Monitor. This product installs in the busway slot and includes 3 CTs that are installed in an end feed unit. Bus Run Monitor has an optional warning light, warning buzzer, or form C contacts to notify facility personnel of a current draw over the preset limit. The preset can be selected at 60-90% of the bus capacity. We believe this is a valid concern but in practice STARLINE Track Busway trips have been extremely rare.
3. How do you identify Phase L1, L2, or L3 device on the power drop boxes?
Each drop box carries a number label either L1, L2, or L3. The color code is determined by the customer’s request. If the customer has no preference, we typically ship 1/3 of the drop boxes wired to each individual phase.
4. How do you know what phase you are plugged into, and how do you allocate the drops so they are balanced across all three phases?
Answer 3 addresses the first half of this question. The answer to the second half is the same as any power distribution system. The electrical designer does the balancing.
FREQUENTLY ASKED QUESTIONS
Application Briefs
Page 9.1 | www.StarlinePower.com
To properly position busway at the minimum distance from wall, first select the largest plug-in unit to be used with the system. Using the provided table as a reference, find the distance (A) to position the busway from the wall. Position the busway and secure into place by tightening the BH-M10 hanger. If a plug-in unit does interfere with the wall, loosen all hanger bolts and move the Busway slightly to allow the plug-in unit to rotate into its final resting position. Ensure that the Busway sections are adjusted evenly to avoid any ‘kinking’ of Busway section joints.
WALL MOUNTING GM100/GM100NG/GM225 SYSTEMS
Application Briefs
Top view of large Circuit Breaker Plug-In shown
Wall
Busway
Conductor side
“A”
3 M. Max.
initial insert position
ENCLOSURE “A” WIDTH 101 mm to 203 mm 101 mm 215 mm to 241 mm 127 mm 266 mm & Up 203 mm
Rotate to install
Busway
GMBH-1 Standard Hanger
Minimum distance from mounting edge surface to enclosure occurs as enclosure edge is in line with rotation center-line of paddle
Loosed GMBH-1 & reposition Busway if enclosure is too close to wall as needed.
Equal
Equal
Page 9.2 | www.StarlinePower.com
Busway plug-in units face toward the conductor side (with the exception of the E9 or “S” enclosure). When installing the busway along a wall, care should be taken to make sure the busway conductor side faces away from the wall. NOTE: Be careful when ordering plug-in units with the busway conductors facing the wall, some plug-in units will have receptacles or breakers facing the wall. Consult the Product Selection Guide to ensure plug-in units selected will face the desired direction. Using MO bolts, mount the short leg of the mounting bracket to your wall/surface (Note: use appropriate bolt type for type of wall/surface. Ensure that the bracket is mounted securely enough to support the weight of the busway and any anticipated plug-in units (maximum allowable weight is 45kg between mounting supports). Space the brackets no more than 3 meters on center.
WALL MOUNTING GM100/GM100N/GM100NG,
& GM225 SYSTEMS
Application Briefs
Polarizing Lip initial insert
position Top view of Circuit Breaker Plug-In
shown
Wall
Busway Power End Feed
Conductor side
Profile of GM225 Busway (GM100,GM100NG are similar
profiles)
Loosen THB-3 & position Busway if enclosure is too close to wall, as needed.
Minimum distance from mounting surface to enclosure occurs as enclosure edge is in line with rotation centerline of paddle.
Wall
Mounting bolts
Busway
BH-1 Standard Hanger
3 m Max.
Page 9.3 | www.StarlinePower.com
Application Briefs 225 AMP WITH 200% NEUTRAL
In certain applications, it is necessary to have a 200% rated neutral. Harmonic currents generated by electronic loads create a neutral current that may approach twice that of the phase currents. For 100 amp applications, STARLINE Track Busway offers a 100 Amp rated busway with a 200% rated neutral for this purpose. For 225 Amp applications, STARLINE Track Busway offers a power feed unit with a dual neutral connection for achieving a 225 Amp rated system with two, independent 225 Amp rated neutrals. In essence, the busway system provides 225 Amps per phase with 200% neutral capacity. Dual Neutral Center Feed Power feeds to a busway system are typically located at the end of the busway system runs, but may be located at any point on the run. A power feed at some intermediate point on the run is called a ‘Center Feed’. In many cases, the center feed is used so that the power tap to the busway can be located at a point convenient for the feeder cable home run. The dual neutral center feed is located at the center of a run and takes advantage of the distributed loads typical in busway applications. Figure 1 shows a traditional busway application in a data center. An end power feed provides power to a series of racks. Racks are evenly spaced, and the load is more or less evenly distributed along the length of the busway. The busway phase and neutral ratings are 225 Amps maximum.
Page 9.4 | www.StarlinePower.com
Application Briefs Figure 2 shows the same busway application with the dual neutral center feed. The dual neutral center feed electrically separates the neutral busbar into two circuits. The dual neutral circuits feed the busway in opposite directions. Figure 3 shows the electrical schematic for the dual neutral power feed unit. As can be seen, the neutral busbar is divided in two, and electrically isolated in the center, thereby provided two, independent neutral circuits. Separate terminal block connections are provided for each neutral feed. Three phase connections and an isolated ground (optional) connection are provided in the normal manner.
Page 9.5 | www.StarlinePower.com
Application Briefs 225 AMP WITH 200% NEUTRAL
Refer again to Figure 2. The system is capable of a total of 225 Amps per phase across the entire system length. More importantly, the system is capable of 225 Amps neutral current to the left of the power feed, and another 225 Amps neutral current to the right of the power feed. The end result is that with a single power feed point and therefore a single conduit home run, the busway system provides 225 Amps per phase and 450 Amps neutral capacity. Features
• Single power feed point • System rated for 225 Amps per phase • System rated for 450 Amps neutral current • Compatible with all STARLINE GM225 and GM100NG (isolated ground) plug-in units. • Cost –efficient double neutral system
Page 9.6 | www.StarlinePower.com
When ordering material it is important to understand the relationship between various components. Examples:
• GM250T5 uses the “T5” series of plug-in units. These plugs are interchangeable with GM400T5 plugs and compatible with other Starline T5series busway systems.
• • ALL COMPONENTS except Housing, Tee, Elbow Sections and Power Feeds are the same
and are interchangeable for GM250T5, GM250T5N (double neutral), GM250T5G and GM250T5NG Amp Systems. Substitute either “GM250T5” or GM250T5N” or “GM250T5G” or “GM250T5NG” for all Housing, Tee, Elbow Sections and Power Feed units.
• Each housing section requires a joint kit. Determine the total number of housing sections (regardless of length) as this becomes the number of Joint Kits (GMJK250T5 series) that will be needed.
o Add one extra Joint Kit for each Tee Section. o No need to add extra Joint Kits for Elbow Sections, as they are already part of
your housing count.
• If this is your first installation for either GM250T5, GM250T5N, GM250T5G or GM250T5NG systems, you will need to order Installation Tool GMT5IT.
• General support hardware rule to follow:
Total System Length + 0.10 (10%) = Support Hardware Qty 10 10 equal 3 m spacing and 10% extra is recommended for job site changes.
• Total Power Feeds and End Caps can be determined by counting the total number of
unconnected runs.
• Before specifying or ordering elbow or tee sections, it is important to understand polarity and the relationship to direction of outlets. Please refer to POLARITY CONCERNS for more detail.
COMPONENT RELATIONSHIP
GM250T5, GM250T5N, GM250T5G, GM250T5NG Systems
Page 9.7 | www.StarlinePower.com
STARLINE utilizes a unique polarizing method to prevent mismatched components from being inadvertently connected to each other. The system is designed to prevent cross phasing during installation. It is particularly important to understand this design concept prior to ordering and/or installing some components. For example, if the face direction of a STARLINE plug-in unit is important in your installation consider that they will always face the conductor side. Certain plug-in units are ‘reversible’, designated by ‘R’, to face devices away from the conductor side.
Tee’s and Elbow Sections are specified according to desired polarity
Stripe side
POLARITY CONCERNS
GM250T5, GM250T5N, GM250T5G, GM250T5NG Systems
Outlet Box always faces polarizing stripe
Outlet Box always faces polarizing stripe
Top View
Outlets Facing
Outlets Facing
Outlets Facing
Outlets Facing
Outlets Facing
Power Feed
Outlets Facing
Polarizing Stripe
Page 9.8 | www.StarlinePower.com
Application Briefs NEUTRAL SIZING-400 AMP SYSTEMS
In certain applications, a customer may want the safeguard of a neutral conductor rated at more than 100% of the phase conductors. For 400 amp applications, STARLINE Track Busway offers a busway system with an oversized neutral busbar. The rating of the oversized neutral is 150% of a 400 Amp phase that is protected by an 80% rated circuit breaker. Thereby a neutral capacity of 480 Amps is achieved. This supplies the customer with 160 Amps of additional capacity on the neutral conductor compared to the maximum phase current. Why Oversized Neutral? There is a concern that with a 3-phase, 4-wire, wye-connected system with nonlinear loads, the neutral may need to carry more than the system’s rated full-load current. According to a IEC report on non-linear loads, in certain instances the neutral conductor current will exceed 100% but will rarely exceed 125% of the rated full-load current. This report can be seen in the 2005 IEC Handbook, IEC article 310.15 (B) 4. To cover the majority of applications, the GM400N system was tested and certified with a neutral rating of 150% of the phase current, with the assumption that the phases are protected with an 80% circuit breaker. 400 Amps (Phase) x 80% (System Protection Breaker) = 320 Amps (Full Load Phase Current) 320 Amps (Full Load Phase Current) x 150% (Oversized Neutral Rating) = 480 Amps (Full Load Neutral Current) The System GM400N and GM400NG System contain all of the features of the standard B400 and B400G systems plus an oversized neutral busbar. This busbar doubles the amount of copper for the neutral in a Busway section. Oversized neutral end feeds are supplied with a double lug for the neutral. The customer will be able to connect to the neutral with two 120 mm2 wires. All other connections have a single wire entry. The maximum voltage rating for the GM400N/GM400NG system is 277Y / 415 volts. The oversized neutral Busway system uses all of the same hardware, plug–in units and accessories as the standard GM400 system uses. Nomenclature GM400N 400A Busway Section with oversized neutral GM400NG 400A Busway Section with oversized neutral and protected Earth GMEF400N 400A End Feed with oversized neutral GMEF400NG 400A End Feed with oversized neutral and protected Earth GMJK400N-1 400A Jointer Kit with oversized neutral GMJK400NG-1 400A Jointer Kit with oversized neutral and protected Earth
Page 9.9 | www.StarlinePower.com
SECTION 16468 – TRACK BUSWAY SYSTEM 1.01 SUMMARY
A. This specification covers the electrical characteristics and general requirements for a track busway system, hereafter referred to as (Track Busway). The system shall be designed primarily for overhead distribution of electrical power. Supporting designated work areas and equipment. Once installed the Busway will provide a simple, versatile, fast and economic means of distributing power. Loads fed from a variety of plug-in units can be easily added or removed without shutting power down to the busway.
1.02 STANDARDS AND CERTIFICATION
A. The Track Busway shall be designed and manufactured to the following standards. 1. Low Voltage Directive (73/23/EEC) including Amendment (93/68/EEC). 2. Low Voltage Switchgear and Control gear Assemblies, Part 1: Type Tested and partially type tested Assemblies, IEC 60439-1: 1999. 3. Low Voltage Switchgear and Control gear Assemblies, Part 2: Particular Requirements for Busbar Trunking systems (Busways), IEC 60439-2: 2000. 4. Underwriters Laboratories Standard, UL 857 – The common UL, CSA, and ANCE Standard for Busways that is derived from the fifth edition of CSA Standard C22.2 No. 27, the twelve edition of UL 857, and the second edition of NMX-J-148-1998-ANCE. 5. CUL Listing 6. National Electric Code (NEC) – Article 364 – Busways 7. NEMA AB1, Molded Case Circuit Breakers and Molded Case Switches 8. NEMA KS-1, Enclosed and Miscellaneous Distribution Equipment Switches (600VAC).
1.03 SYSTEM DESCRIPTION A. Electrical Requirements STARLINE TRACK BUSWAY – Manufactured by Universal Electric Corp. 168 Georgetown Road Canonsburg, PA 15317 Phone # (724) 597-7800
Voltage 240/415V
Frequency: 50/60 Hz Ampacity: 100A /225 A Neutral Ampacity: 225 A Conductors: Qty 4 (Phases L1, L2, L3 and Neutral).
Earth: Aluminum Casing
System Designation:
System Amperage Neutral Iso Ground GM100 100 100 No GM100N 100 200 No GM100NG 100 200 Yes GM225 225 225 No
B. Environmental
Indoor, Low Impedance System Ambient Operating Temperature: 40C / 104F 60C / 140F (0.8 Amp Rating Multiplier)
Page 10.1 | www.StarlinePower.com
SECTION 16468 – TRACK BUSWAY SYSTEM GM100G, GM100NG, GM100N, GM225 1.01 SUBMITTALS
A. Submittals shall be in accordance with specified procedures. Submit shop drawing and product data for record purposes prior to shipment. B. Indicate construction details, including dimensions, weights, clearances, major component layout, power details. Include circuit breaker, fused plug-in, and cable schedule (if applicable), including cable lengths and plug-in schedules. C. Include connection diagram for external wiring, and details of conduit and wiring connections and terminations. D. Indicate special receiving and handling procedures. E. Provide electrical characteristics and connection requirements for the system and accessories.
1.02 WARRANTY
A. The Track Busway manufacturer shall guarantee the entire system against defective material and workmanship for a period of one (1) year from date of shipment.
1.06 COMPONENTS
A. Frame and Enclosure:
1. Extruded Aluminum housing designed to act as a 100% ground. Housings to be 3 or 6 Metres standard length. This housing should be properly extruded with slots to receive rod mount hangers to hang from a ceiling. This housing should be open on the bottom to accept plug-in units anywhere along its length. This opening shall pass UL’s hypothetical finger probe test.
2. All conductors shall be made of copper and sized to handle 100% of it’s rating continuously with ambient temperatures below 40C / 104F. The conductors shall be electrically isolated from the housing.
B. Plug-in Units 1. Plug-in units shall be polarized to avoid incorrect installation. 2. Plug-in units shall use [{circuit breakers} {fuses}] for branch circuit protection. 3. Plug-in units shall have locking clips or bolt-on tabs to secure units to the busway. 4. Plug-in units that include drop cords shall be manufactured with cord grips and receptacles as specified in the drawings.
1.07 INSTALLATION
A. Track Busway Sections – The runs will consist of lengths as shown on the drawings. B. Hanging of the Track Busway – Using supplied ‘Rod Mount Hangers’ the busway will be hung from the ceiling using all thread. The installing contractor shall be responsible for the connections on the ceiling end. The supplied Rod Mount Hangers will connect the track busway to the all thread. The maximum spacing is 3 m on center for the hangers. The height of the track busway shall be coordinated with the Architect. C. Connecting Sections of Track Busway – At a junction of Track Busway sections, the installer will install the top housing coupler; the bus connector is inserted, centered and seated in the slot of the Busway. The installation tool is inserted into jointed intersection and rotated 90 deg. Forcing stabs into u-shaped female conductors. Housing coupler is positioned over the bottom joint and tightened. A manufacturer supplied tool will assist in joining sections together. D. End of Runs – End caps will be provided to install at the ends of each run. E. Closure Strip – The closure strip can be cut and fitted to cover the bottom opening of the Track Busway housing to prevent dust and debris from gathering in the Track Busway (if applicable). Supply as manufactured by Universal Electric Corporation; 168 Georgetown Rd; Canonsburg, PA 15317; USA +1 724 597-7800; fax +1 724- 916-2221.
Page 10.2 | www.StarlinePower.com
1.01 SUMMARY
A. This specification covers the electrical characteristics and general requirements for a track busway system, hereafter referred to as (Track Busway). The system shall be designed primarily for overhead distribution of electrical power. Supporting designated work areas and equipment. Once installed the Busway will provide a simple, versatile, fast and economic means of distributing power. Loads fed from a variety of plug-in units can be easily added or removed without shutting power down to the busway.
1.02 STANDARDS AND CERTIFICATION
A. The Track Busway shall be designed and manufactured to the following standards: 1. Underwriters Laboratories Standard, UL 857 – The common UL, CSA, and ANCE Standard for Busways that is derived from the fifth edition of CSA Standard C22.2 No. 27, the twelfth edition of UL 857, and the second edition of NMX-J-148-1998-ANCE. 2. Low Voltage Switchgear and Controlgear Assemblies, Part 1: Type Tested and partially type tested Assemblies, IEC 60439-1: 1999. 3. Low Voltage Switchgear and Controlgear Assemblies, Part 2: Particular Requirements for Busbar Trunking systems (Busways), IEC 60439-2: 2000.Low Voltage Directive (73/23/EEC) including Amendment (93/68/EEC). 4. ETL Certified (US/Canada) to UL857 5. National Electric Code (NEC) – Article 368 – Busways 6. NEMA AB1, Molded Case Circuit Breakers and Molded Case Switches 7. NEMA KS-1, Enclosed and Miscellaneous Distribution Equipment Switches (600VAC).
1.03 SYSTEM DESCRIPTION A. Electrical Requirements STARLINE Track Busway - Manufactured by: Universal Electric Corp. 168 Georgetown Rd. Canonsburg, PA 15317 (724) 597-7800
Voltage: 415 V AC/DC Frequency: 50/60 Hz Ampacity: 250A Neutral Ampacity: 250 or 500A Conductors: 3 Phase conductors, 1 Neutral
Conductor Solid Copper, Tin Plated
Earth: Aluminum Casing System Designation:
System Amperage Neutral Iso Ground GM250T5 250 250 No GM250T5G
250 250 Yes
GM250T5N 250 500 No GM250T5N 250 500 Yes
B. Environmental
Indoor, Low Impedance System Ambient Operating Temperature: 40°C / 104°F 60°C / 140°F (0.8 Amp Rating Multiplier)
1.04 SUBMITTALS
A. Indicate construction details, including dimensions, weights, clearances, major component layout, power details. Include circuit breaker, fused plug-in, and cable schedule (if applicable), including cable lengths and plug-in schedules. B. Include connection diagram for external wiring, and details of conduit and wiring connections and terminations. C. Indicate special receiving and handling procedures. D. Provide electrical characteristics and connection requirements for the system and accessories. 1.05 WARRANTY A. The Track Busway manufacturer shall guarantee the entire system against defective material and workmanship for a period of one (1) year from date of shipment.
SECTION 16468 – TRACK BUSWAY SYSTEM GM250T5, GM250T5G, GM250T5N, GM250T5NG
Page 10.3 | www.StarlinePower.com
1.06 COMPONENTS
A. Frame and Enclosure 1. Extruded Aluminum housing designed to act as a 100% ground. Housings to be 3 or 4.5 M standard length. This housing should be properly extruded with slots to receive rod mount hangers to hang from a ceiling. This housing should be open on the bottom to accept plug-in units anywhere along its length. This opening shall pass UL’s hypothetical finger probe test. 2. All conductors shall be made of copper and sized to handle 100% of its rating continuously with ambient temperatures below 40°C / 104°F. The conductors shall be electrically isolated from the housing.
B. Plug-in Units 1. Plug-in units shall be polarized to avoid incorrect installation. 2. Plug-in units shall use [{circuit breakers} {fuses}] for branch circuit protection. 3. Plug-in units shall have locking clips or bolt-on tabs to secure units to the busway. 4. Plug-in units that include drop cords shall be manufactured with cord grips and receptacles as specified in the drawings.
1.07 INSTALLATION A. Track Busway Sections – The runs will consist of lengths as shown on the drawings. B. Hanging of the Track Busway – Using supplied ‘Rod Mount Hangers’ the busway will be hung from the ceiling using all thread. The installing contractor shall be responsible for the connections on the ceiling end. The supplied Rod Mount Hangers will connect the track busway to the all thread. The maximum spacing is 3M on center for the hangers. The height of the track busway shall be coordinated with the Architect. C. Connecting Sections of Track Busway – At a junction of Track Busway sections, the installer will install the top housing coupler; the bus connector is inserted, centered and seated in the slot of the Busway. The installation tool is inserted into jointed intersection and rotated 90 deg. Forcing stabs into u-shaped female conductors. Housing coupler is positioned over the bottom joint and tightened. A manufacturer supplied tool will assist in joining sections together. D. End of Runs – End caps will be provided to install at the ends of each run.
E. Closure Strip – The closure strip can be cut and fitted to cover the bottom opening of the Track Busway housing to prevent dust and debris from gathering in the Track Busway (if applicable). Supply as manufactured by Universal Electric Corporation 168 Georgetown Rd Canonsburg, PA 15317 (800) 245-6378; (724) 597-7800; fax (724) 916-2221. No known equal.
END OF SECTION
SECTION 16468 – TRACK BUSWAY SYSTEM GM250T5, GM250T5N, GM250T5G, GM250T5NG
Page 10.4 | www.StarlinePower.com
Voltage: 415 V AC/DC Frequency: 50 Hz Ampacity: 400A Neutral Ampacity: 400A or 800A Conductors: Qty 4 (Phases L1, L2, L3 and
Neutral) Earth: Aluminum Casing
System Designation:
System Amperage Neutral Iso Ground
GM400 400 400 No GM400N 400 800 No GM400G 400 400 Yes GM400NG 400 800 Yes
B. Environmental
Indoor, Low Impedance System Ambient Operating Temperature: 40°C / 104°F 60°C / 140°F (0.8 Amp Rating Multiplier)
1.04 SUBMITTALS A. Submittals shall be in accordance with specified procedures. Submit shop drawing and product data for record purposes prior to shipment. B. Indicate construction details, including dimensions, weights, clearances, major component layout, power details. Include circuit breaker, fused plug-in, and cable schedule (if applicable), including cable lengths and plug-in schedules. C. Include connection diagram for external wiring, and details of conduit and wiring connections and terminations. D. Indicate special receiving and handling procedures. E. Provide electrical characteristics and connection requirements for the system and accessories. 1.05 WARRANTY A. The Track Busway manufacturer shall guarantee the entire system against defective material and workmanship for a period of one (1) year from date of shipment.
1.01 SUMMARY
A. This specification covers the electrical characteristics and general requirements for a track busway system, hereafter referred to as (Track Busway). The system shall be designed primarily for overhead distribution of electrical power. Supporting designated work areas and equipment. Once installed the Busway will provide a simple, versatile, fast and economic means of distributing power. Loads fed from a variety of plug-in units can be easily added or removed without shutting power down to the busway. 1.02 STANDARDS AND CERTIFICATION
A. The Track Busway shall be designed and manufactured to the following standards:
1. Low Voltage Directive (73/23/EEC) including Amendment (93/68/EEC). 2. Low Voltage Switchgear and Controlgear Assemblies, Part 1: Type Tested and partially type tested Assemblies, IEC 60439-1: 1999. 3. Low Voltage Switchgear and Controlgear Assemblies, Part 2: Particular Requirements for Busbar Trunking systems (Busways), IEC 60439-2: 2000. 4. Underwriters Laboratories Standard, UL 857 – The common UL, CSA, and ANCE Standard for Busways that is derived from the fifth edition of CSA Standard C22.2 No. 27, the twelvth edition of UL 857, and the second edition of NMX-J-148-1998-ANCE. 5. ETL Classified (US/Canada) to UL857 6. National Electric Code (NEC) – Article 368 – Busways 7. NEMA AB1, Molded Case Circuit Breakers and Molded Case Switches 8. NEMA KS-1, Enclosed and Miscellaneous Distribution Equipment Switches (600VAC).
1.03 SYSTEM DESCRIPTION
A. Electrical Requirements
STARLINE Track Busway Manufactured by: Universal Electric Corp. 168 Georgetown Rd. Canonsburg, PA 15317 (724) 597-7800
SECTION 16468 – TRACK BUSWAY SYSTEM GM400, GM400N, GM400G, GM400NG
Page 10.5 | www.StarlinePower.com
1.06 COMPONENTS
A. Frame and Enclosure 1. Extruded Aluminum housing designed to act as a 100% ground. Housings to be 1.5 or 3m standard length. This housing should be properly extruded with slots to receive rod mount hangers to hang from a ceiling. This housing should be open on the bottom to accept plug-in units anywhere along its length. This opening shall pass UL’s hypothetical finger probe test. 2. All conductors shall be made of copper and sized to handle 100% of it’s rating continuously with ambient temperatures below 40°C / 104°F. The conductors shall be electrically isolated from the housing.
B. Plug-in Units 1. Plug-in units shall be polarized to avoid incorrect installation. 2. Plug-in units shall use [{circuit breakers} {fuses}] for branch circuit protection. 3. Plug-in units shall have locking clips or bolt-on tabs to secure units to the busway. 4. Plug-in units that include drop cords shall be manufactured with cord grips and receptacles as specified in the drawings.
1.07 INSTALLATION
A. Track Busway Sections – The runs will consist of lengths as shown on the drawings.
B. Hanging of the Track Busway – Using supplied ‘Rod Mount Hangers’ the busway will be hung from the ceiling using all thread. The installing contractor shall be responsible for the connections on the ceiling end. The supplied Rod Mount Hangers will connect the track busway to the all thread. The maximum spacing is 3m on center for the hangers. The height of the track busway shall be coordinated with the Architect. C. Connecting Sections of Track Busway – At a junction of Track Busway sections, the installer will install the top housing coupler; the bus connector is inserted, centered and seated in the slot of the Busway. The installation tool is inserted into jointed intersection and rotated 90 deg. Forcing stabs into u-shaped female conductors. Housing coupler is positioned over the bottom joint and tightened. A manufacturer supplied tool will assist in joining sections together.
D. End of Runs – End caps will be provided to install at the ends of each run. E. Closure Strip – The closure strip can be cut and fitted to cover the bottom opening of the Track Busway housing to prevent dust and debris from gathering in the Track Busway (if applicable). Supply as manufactured by Universal Electric Corporation 168 Georgetown Rd Canonsburg, PA 15317 (800) 245-6378; (724) 597-7800; fax (724) 916-2221. No known equal.
END OF SECTION
SECTION 16468 – TRACK BUSWAY SYSTEM GM400, GM400N, GM400G, GM400NG
Page 10.6 | www.StarlinePower.com
1.01 SUMMARY
A. This specification covers the electrical characteristics and general requirements for a track busway system, hereafter referred to as (Track Busway). The system shall be designed primarily for overhead distribution of electrical power. Supporting designated work areas and equipment. Once installed the Busway will provide a simple, versatile, fast and economic means of distributing power. Loads fed from a variety of plug-in units can be easily added or removed without shutting power down to the busway. 1.02 STANDARDS AND CERTIFICATION
A. The Track Busway shall be designed and manufactured to the following standards: 1. Underwriters Laboratories Standard, UL 857 – The common UL, CSA, and ANCE Standard for Busways that is derived from the fifth edition of CSA Standard C22.2 No. 27, the twelfth edition of UL 857, and the second edition of NMX-J-148-1998-ANCE. 2. Low Voltage Switchgear and Controlgear Assemblies, Part 1: Type Tested and partially type tested Assemblies, IEC 60439-1: 1999. 3. Low Voltage Switchgear and Controlgear Assemblies, Part 2: Particular Requirements for Busbar Trunking systems (Busways), IEC 60439-2: 2000.Low Voltage Directive (73/23/EEC) including Amendment (93/68/EEC). 4. ETL Certified (US/Canada) to UL857 5. National Electric Code (NEC) – Article 368 – Busways 6. NEMA AB1, Molded Case Circuit Breakers and Molded Case Switches 7. NEMA KS-1, Enclosed and Miscellaneous Distribution Equipment Switches (600VAC). 8. NFPA 70 – National Fire Protection Agency 1.03 SYSTEM DESCRIPTION
A. Electrical Requirements STARLINE Track Busway Manufactured by: Universal Electric Corp. 168 Georgetown Rd. Canonsburg, PA 15317 (724) 597-7800
Voltage: 415 V AC/DC Frequency: 50/60 Hz Ampacity: 800A Neutral Ampacity: 800A Conductors: 3 Phase conductors, 1 Neutral
Conductor Copper: Solid Copper, Nickel Plated Composite: Continuous nickel plated
Copper contact surface within nickel plated aluminum busbar
Earth: Aluminum Casing
System Designation: System Amperage Neutral Iso Ground GM800T5CC
800 800 No
GM800T5GCC
800 800 Yes
GM800T5CA 800 800 No GM800T5GCA
800 800 Yes
B. Environmental Indoor, Low Impedance System Ambient Operating Temperature: 40°C / 104°F 60°C / 140°F (0.8 Amp Rating Multiplier)
1.04 SUBMITTALS
A. Submittals shall be in accordance with specified procedures. Submit shop drawing and product data for record purposes prior to shipment. B. Indicate construction details, including dimensions, weights, clearances, major component layout, power details. Include circuit breaker, fused plug-in, and cable schedule (if applicable), including cable lengths and plug-in schedules. C. Include connection diagram for external wiring, and details of conduit and wiring connections and terminations. D. Indicate special receiving and handling procedures. E. Provide electrical characteristics and connection requirements for the system and accessories.
1.05 WARRANTY
A. The Track Busway manufacturer shall
guarantee the entire system against defective material and workmanship for a period of one (1) year from date of shipment.
SECTION 16468 – TRACK BUSWAY SYSTEM GM800T5CG, GM800T5GCC, GM800T5CA, GM800T5GCA
Page 10.7 | www.StarlinePower.com
1.06 COMPONENTS
A. Frame and Enclosure 1. Extruded Aluminum housing certified to serve as a 100% ground. Housings to be 1.5 – 3m standard length. This housing should be properly extruded with slots to receive rod mount hangers to hang from a ceiling. This housing should be open on the bottom to accept plug-in units anywhere along its length. 2. All conductors shall be made of copper or composite copper/aluminum and sized to handle 100% of it’s rating continuously with ambient temperatures below 40°C / 104°F. The conductors shall be electrically isolated from the housing. B. Plug-in Units 1. Plug-in units shall be polarized to avoid incorrect installation. 2. Plug-in units shall use [{circuit breakers} {fuses}] for branch circuit protection. 3. Plug-in units shall have locking clips or bolt-on tabs to secure units to the busway. 4. Plug-in units that include drop cords shall be manufactured with cord grips and receptacles as specified in the drawings.
1.07 INSTALLATION
A. Track Busway Sections – The runs will consist of lengths as shown on the drawings.
B. Hanging of the Track Busway – Using supplied ‘Rod Mount Hangers’ the busway will be hung from the ceiling using all thread. The installing contractor shall be responsible for the connections on the ceiling end. The supplied Rod Mount Hangers will connect the track busway to the all thread. The maximum spacing is 3m on center for the hangers. The height of the track busway shall be coordinated with the Architect. C. Connecting Sections of Track Busway – At a junction of Track Busway sections, the installer will install the top housing coupler; the bus connector is inserted, centered and seated in the slot of the Busway. The installation tool is inserted into jointed intersection and rotated 90 deg. Forcing stabs into u-shaped female conductors. Housing coupler is positioned over the bottom joint and tightened. A manufacturer supplied tool will assist in joining sections together.
D. End of Runs – End caps will be provided to install at the ends of each run. E. Closure Strip – The closure strip can be cut and fitted to cover the bottom opening of the Track Busway housing to prevent dust and debris from gathering in the Track Busway (if applicable).
Supply as manufactured by Universal Electric Corporation 168 Georgetown Rd Canonsburg, PA 15317 (800) 245-6378; (724) 597-7800; fax (724) 916-2221 No known equal.
END OF SECTION
SECTION 16468 – TRACK BUSWAY SYSTEM GM800T5CG, GM800T5GCC, GM800T5CA, GM800T5GCA
Page 10.8 | www.StarlinePower.com
F0000014 11/13
www.StarlinePower.com | [email protected]
UK & Northern EuropeCity Point, 1 Ropemaker Street London EC2Y 9HT +44 207 153 1950
Asia Pacific Region OfficeLevel 8 Samsung Hub 3 Church Street Singapore 049483 +65 6408 0165
S.W Asia Region OfficeGround Floor, E-1 Block, Beech Building Manyata Embassy Business Park Outer Ring Road Bangalore, India 560045 +91 80 4276 4627
United States 168 Georgetown Road Canonsburg, PA 15317 +1 724 597 7800
Most STARLINE systems and most standard components are UL, CE or ETL listed.IEC 61439-6 Edition 1.0 2012-05 Low-voltage switchgear and controlgear assemblies – Part 6: Busbar trunking systems (busways)
Universal Electric Corporation (UEC), the manufacturer of STARLINE, has been a leader in power distribution since 1924. The company’s founders led the way for many new technologies in thepower distribution equipment industry. Today, this family tradition of innovation continues to pave theway for safer, more innovative and more reliable electrical power distribution systems. Visitwww.StarlinePower.com for your Flexible Power Solutions. For installation details, ElectricalEstimating cost comparisons, and actual case histories of projects where savings with STARLINEhave been documented, contact UEC’s Customer Service Department at the locations listed below.
F0900008 9/2014