www.entes.com.tr
Product Code
GKRC-M2
Sin
gle
-phase
GKRC-02
GKRC-01
GKRC-03
GKRC-02FA
Au
xilia
ryS
up
ply
GKRC-03F
WithoutN
eutr
al
GKRC-02F
DGRC-01
MCC-3D
Dela
y-O
n
DIN
2R
ail
Mo
un
t
GKRC-20F
DIN
1R
ail
Mount
pcs
/cart
on
10
10
10
10
10
10
10
10
24
10
Over
Voltage
Under
Voltage
Phase
Seq.
Failu
re
Dela
y-O
ff
VOLTAGE MONITORING RELAYS
GKR / DGRC / MCC Series (Under / Over Voltage)
MCC-1D
SPECIFICATIONS
Electrical Parameters
Operating Voltage (Un)
Network Type
Under Voltage Adj. Interval
Instant Tripping
Instant Tripping Time
Hysteresis
Output Contact
Dimensions
Weight / each
Quantity in 1 package
3-phase / 4 wire(Star)
1 phase /2 wire
< 500 msec
3%
1 C/O, 8 A, 2000 VA (cos =1)�
24 pcs
0,25 kg
PK25
230 V AC, ±10%
3-phase / 3 wire(Delta)
400 V AC, ±10%
50/60 Hz
(0,70-0,95)xUn
MODE SL
DG
RC
-01
MC
C-1
D
MC
C-3
D
(0,70-0,95)xUn
� 0,5xUn 168 V AC
1 N/O, 8 A, 2000 VA (cos =1)�
PK22 (DIN I)
0,1 kg
3-phase / 4 wire(Star)
1 phase /2 wire
3-phase / 4 wire(Star)
-
-
230 V AC, ±10%
Mechanical Parameters
(new
)
GK
RC
-20F
GK
RC
-0F
2
GK
RC
-02
GK
RC
-0FA
2
GK
RC
-03
GK
RC
-03F
GK
RC
-M2
0,1 kg0,25 kg
PK25 PK22 (DIN1)
400 V AC, ±30%230 V AC, ±30%
1-phase / 2 wire3-phase / 4 wire (Star)
Over Voltage Adj. Interval
Operating Frequency
(1,05-1,30)xUn
(0,70-0,95)xUn
(1,05-1,30)xUn
(0,80-1,30)xUn
(0,70-1,20)xUn
� 1,5xUn� 0,5xUn
The relay is directly connected to thenetwork and the required under / overvoltage limit is adjustable by knobs.
n the
When the monitored voltages of all3-phase are within the preset limits,the output relay switches ON.Faulty tripping operations effected
e
from instantaneous voltage peaks areprevented with the adjustable delayedtripping between 0 1 and 10 seconds.
If any of the monitored phase voltageexceeds the set value, delay timstarts to count.If any of the phase voltages exceed1 5xUn, the relay switches OFF without
,
,
delay (within less than 500msec.) If anyof the phase voltages falls bel w 0 5xUn,the relay switches without delay(within less than 500 msec.)If the voltage value returns within presetlimits before the end of counting time
.o ,
OFF
,the delay time ends and relay continuesto its normal operation.
GKRC-02FA
Operating Principle
General
GKRC type over and under / over voltage monitoring relays aredesigned to protect single phase or three phase systems fromvoltage variations and phase sequence failure.
.
Note: These relays include the feature of switching OFF
immediately if any of the phases exceeds (or reduces from)
the nominal voltage by 50%
Non-flammable enclosure
Protection Degree: IP 0Ambient Operating Temperature : -5 C, +50 CIEC 60255-3, IEC 60255-6, IEC 60870-5, IEC 60529
Rail-mounted or surface mounted with clips2
o o
DGRC type under voltage monitoring relays are designed toprotect single phase or three phase systems from lastingunder voltage variations.
GKRC-20F
3-P
hase
MCC-1D 5-15 min. Delay-Off
5-15 min. Delay-Off
24
41
www.entes.com.tr
Utilization with Single-Phase and Two-Phase Systems
(For only GKR-01/02, GKRC-01/02, DGR-01, DGRC-01)
See following connection diagrams for both cases:
Single Phase Connection Diagram
N L1 L2 L3
L1N
Two Phase Connection Diagram
L1L2N
N L1 L2 L3
Auxiliary Supply Connection Diagram (For only GKRC-02FA)
U> U< On Out
0.700.75
0.80
0.90 0.95
1.05
1.15
1.20
1.25 1.30
1.10
0.85
xUn
xUn
2
4
8
t (sn.)
10
0.1
1 2 3
N L
L
System
N
N
12
3
GKRC
GKRC-M2DGRC-01
U< On Out
1.05
1.15
1.20
1.25 1.30
1.10
xUn
1 2 3
N L1 L2 L3
L1
L2
L3
NSystem
N
2
4
8
t (sn.)
10
0.1
12
3
DGRC
GKRC-02 / GKRC-02F
U> On Out
1.05
1.15
1.20
1.25 1.30
1.10
xUn
1 2 3
N L1 L2 L3
L1
L2
L3
NSystem
N
2
4
8
t (sn.)
10
0.1
12
3
GKRC
GKR-03 / GKRC-03F
U> U< On Out
0.700.75
0.80
0.90 0.95
1.05
1.15
1.20
1.25 1.30
1.10
0.85
xUn
xUn
2
4
8
t (sn.)
10
0.1
1 2 3
L1 L2 L3
L1
L2
L3
System
N
12
3
GKRC
GKRC-01
U> U< On Out
0.700.75
0.80
0.90 0.95
1.05
1.15
1.20
1.25 1.30
1.10
0.85
xUn
xUn
2
4
8
t (sn.)
10
0.1
1 2 3
N L1 L2 L3
L1
L2
L3
NSystem
N
12
3
GKRC
L1L2L3
A1 A2 L1 L2 L3
A1A2
GKRC-02FA
Vin (L-L)
L1 L2 L3
L1
L2
L3 System
N
Un
1 2 3
1
2
3
108
6
4
2 0.1
t(s)
OUTON
U<U>
(V)
400
340
320 300
360
380
(V)
500480
460
440
420 400
A1
A2
A2
A1
GKRC-02FA
VOLTAGE MONITORING RELAYS
GKR / DGRC / MCC Series (Under / Over Voltage)
DimensionsConnection Diagram
L1
L2
L3
N
System
N
L1 2
On
Out
13
5 7
9
1115
t (m.)
L2 N L3
MCC-3D
1
21
TYPE PK 22
SystemL
N
N
2
On
Out
13
5 7
9
1115
t (m.)
L
MCC-1D
1
N
21
Connection diagrams are given for reference. Please always check latest user manual given with product or download from www.entes.com.tr.the
MCC-1D MCC-3D
19
61
90
28
48
58
45
35
90
45
62
58
32
48
35
TYPE PK25
N L3
L1 L2
15
16 18
A1 15
R
A2 16 18
L
N
N L3
L1 L2
15
16 18
A1 15
R
A2 16 18
L1
N
L2L3
GKRC-20F
GKRC-20F
87
45
17,560
445
TYPE PK 27