GIIIA Generators: G40 SIIIA and G60 SIIIA...Engine: Yanmar 4TNV98T-ZGGE Alternator: LSA 42.3 S5 G60...

30
GIIIA Generators: G40 SIIIA and G60 SIIIA

Transcript of GIIIA Generators: G40 SIIIA and G60 SIIIA...Engine: Yanmar 4TNV98T-ZGGE Alternator: LSA 42.3 S5 G60...

Page 1: GIIIA Generators: G40 SIIIA and G60 SIIIA...Engine: Yanmar 4TNV98T-ZGGE Alternator: LSA 42.3 S5 G60 GIIIA unit Engine: JD 4045 HFG81 Alternator: LSA 42.3 L9 Package Layout Review Engine

GIIIA Generators: G40 SIIIA and G60 SIIIA

Page 2: GIIIA Generators: G40 SIIIA and G60 SIIIA...Engine: Yanmar 4TNV98T-ZGGE Alternator: LSA 42.3 S5 G60 GIIIA unit Engine: JD 4045 HFG81 Alternator: LSA 42.3 L9 Package Layout Review Engine

Page 1

INDEX

GIIIA Project steps Package Layout Review Air inlets/outlet Water ingression improvements Engines / Alternators Cooling system Heat and rotation parts – safety Options Lifting Bail Power Pedestal

Page 3: GIIIA Generators: G40 SIIIA and G60 SIIIA...Engine: Yanmar 4TNV98T-ZGGE Alternator: LSA 42.3 S5 G60 GIIIA unit Engine: JD 4045 HFG81 Alternator: LSA 42.3 L9 Package Layout Review Engine

Page 2

GIIIA Project steps

GIIIA Project: • Change engines from Stage II to Stage IIIA • Opportunity to have a re-design Steps: 1. G150-200 2. G80-100 3. G400-500 4. G60 5. G20-30-40 6. G250 (Only re-design as the engine is already Stage IIIA compliant)

Page 4: GIIIA Generators: G40 SIIIA and G60 SIIIA...Engine: Yanmar 4TNV98T-ZGGE Alternator: LSA 42.3 S5 G60 GIIIA unit Engine: JD 4045 HFG81 Alternator: LSA 42.3 L9 Package Layout Review Engine

Page 3

• Large air inlet grills on the side

• Water and dust ingress despite inside baffles

Package Layout Review

Air inlets GII

Page 5: GIIIA Generators: G40 SIIIA and G60 SIIIA...Engine: Yanmar 4TNV98T-ZGGE Alternator: LSA 42.3 S5 G60 GIIIA unit Engine: JD 4045 HFG81 Alternator: LSA 42.3 L9 Package Layout Review Engine

Page 4

- All inlets has grill - Originally we had five back side “packets” - Three and one on front side doors is better solution due to noise and cooling

Package Layout Review

Air inlets GIIIA

Page 6: GIIIA Generators: G40 SIIIA and G60 SIIIA...Engine: Yanmar 4TNV98T-ZGGE Alternator: LSA 42.3 S5 G60 GIIIA unit Engine: JD 4045 HFG81 Alternator: LSA 42.3 L9 Package Layout Review Engine

Page 5

- Only one on the unite - All hot air is pushed up (similar as today) - Grill was replaced by louvers which gives better noise result and water ingression improvement potential

Package Layout Review

Air outlet

Page 7: GIIIA Generators: G40 SIIIA and G60 SIIIA...Engine: Yanmar 4TNV98T-ZGGE Alternator: LSA 42.3 S5 G60 GIIIA unit Engine: JD 4045 HFG81 Alternator: LSA 42.3 L9 Package Layout Review Engine

Page 6

“Pocket” system - All inlets are made with “pockets” - all pockets are water proved - Pocket system helps also with noise reduction

Package Layout Review

Water ingression improvements

Page 8: GIIIA Generators: G40 SIIIA and G60 SIIIA...Engine: Yanmar 4TNV98T-ZGGE Alternator: LSA 42.3 S5 G60 GIIIA unit Engine: JD 4045 HFG81 Alternator: LSA 42.3 L9 Package Layout Review Engine

Page 7

- Roof is made from ONE back and ONE front panel - Lifting bail is used as a channel - Roof panels are put over LB edge - raised lifting eye

Package Layout Review

Water ingression improvements

Page 9: GIIIA Generators: G40 SIIIA and G60 SIIIA...Engine: Yanmar 4TNV98T-ZGGE Alternator: LSA 42.3 S5 G60 GIIIA unit Engine: JD 4045 HFG81 Alternator: LSA 42.3 L9 Package Layout Review Engine

Page 8

- Back door is fully down and sealed (also more compact design) - Ring around exhaust pipe together with louvers helps with water ingression from exhaust side of unit

Package Layout Review

Water ingression improvements

Page 10: GIIIA Generators: G40 SIIIA and G60 SIIIA...Engine: Yanmar 4TNV98T-ZGGE Alternator: LSA 42.3 S5 G60 GIIIA unit Engine: JD 4045 HFG81 Alternator: LSA 42.3 L9 Package Layout Review Engine

Page 9

- Example of using baffles and fiberglass, those are used mainly on exhaust area and up top of engine exhaust piping - At the roof and on places where is necessary, holding pins are used

Package Layout Review

Baffles, foams, fiberglass

Page 11: GIIIA Generators: G40 SIIIA and G60 SIIIA...Engine: Yanmar 4TNV98T-ZGGE Alternator: LSA 42.3 S5 G60 GIIIA unit Engine: JD 4045 HFG81 Alternator: LSA 42.3 L9 Package Layout Review Engine

Page 10

• Interior design / layout is similar to today serial production with improvements:

• no J-Box • simple LB design • simple fan guard

Package Layout Review

Interior

Page 12: GIIIA Generators: G40 SIIIA and G60 SIIIA...Engine: Yanmar 4TNV98T-ZGGE Alternator: LSA 42.3 S5 G60 GIIIA unit Engine: JD 4045 HFG81 Alternator: LSA 42.3 L9 Package Layout Review Engine

Page 11

G40 GIIIA unit Engine: Yanmar 4TNV98T-ZGGE Alternator: LSA 42.3 S5 G60 GIIIA unit Engine: JD 4045 HFG81 Alternator: LSA 42.3 L9

Package Layout Review

Engine / Alternator overall details

Page 13: GIIIA Generators: G40 SIIIA and G60 SIIIA...Engine: Yanmar 4TNV98T-ZGGE Alternator: LSA 42.3 S5 G60 GIIIA unit Engine: JD 4045 HFG81 Alternator: LSA 42.3 L9 Package Layout Review Engine

Page 12

- External fuel tank option, also oil pump option and oil, water drains are all on same side

Package Layout Review

Options

Page 14: GIIIA Generators: G40 SIIIA and G60 SIIIA...Engine: Yanmar 4TNV98T-ZGGE Alternator: LSA 42.3 S5 G60 GIIIA unit Engine: JD 4045 HFG81 Alternator: LSA 42.3 L9 Package Layout Review Engine

Page 13

- New type of 3-valve, more robust handle - Two different way how can be used: -Complete set up to external connection parts -Ready for customer connection

Package Layout Review

3 Way Fuel Valve (3WFV, 3WFVE)

Page 15: GIIIA Generators: G40 SIIIA and G60 SIIIA...Engine: Yanmar 4TNV98T-ZGGE Alternator: LSA 42.3 S5 G60 GIIIA unit Engine: JD 4045 HFG81 Alternator: LSA 42.3 L9 Package Layout Review Engine

Page 14

- Used to be as a standard - New position of G200 serial production robust pump - External connection is placed to the frame (right from water drain plug)

Package Layout Review

Oil pump option

Page 16: GIIIA Generators: G40 SIIIA and G60 SIIIA...Engine: Yanmar 4TNV98T-ZGGE Alternator: LSA 42.3 S5 G60 GIIIA unit Engine: JD 4045 HFG81 Alternator: LSA 42.3 L9 Package Layout Review Engine

Page 15

Package Layout Review

12 / 24h fuel tank / BB overall details

- Standard fuel tank is designed for 12 hours runtime at 75% load,

- Optional fuel tank - 24 hours runtime (75% load)

- Bunded Base has sufficient volume for 110 % of all fluids

- Step integrated in fuel tank floor to aid low fuel sensing and fuel pick-up of small quantities.

- Prepared for easy cleaning by fuel filling hole & Bunded Base/fuel tank drains.

- Bunded Base & fuel tank drains are axially aligned

- Fuel tank to be drained by extension screwed pipe

Page 17: GIIIA Generators: G40 SIIIA and G60 SIIIA...Engine: Yanmar 4TNV98T-ZGGE Alternator: LSA 42.3 S5 G60 GIIIA unit Engine: JD 4045 HFG81 Alternator: LSA 42.3 L9 Package Layout Review Engine

Page 16

Package Layout Review

12 / 24h fuel tank / BB drains

Page 18: GIIIA Generators: G40 SIIIA and G60 SIIIA...Engine: Yanmar 4TNV98T-ZGGE Alternator: LSA 42.3 S5 G60 GIIIA unit Engine: JD 4045 HFG81 Alternator: LSA 42.3 L9 Package Layout Review Engine

Page 17

step 0

step 1 step 2 step 3 step 4

Package Layout Review

12 / 24h fuel tank – switchable design

Page 19: GIIIA Generators: G40 SIIIA and G60 SIIIA...Engine: Yanmar 4TNV98T-ZGGE Alternator: LSA 42.3 S5 G60 GIIIA unit Engine: JD 4045 HFG81 Alternator: LSA 42.3 L9 Package Layout Review Engine

Page 18

Package Layout Review

Frame protection option

Page 20: GIIIA Generators: G40 SIIIA and G60 SIIIA...Engine: Yanmar 4TNV98T-ZGGE Alternator: LSA 42.3 S5 G60 GIIIA unit Engine: JD 4045 HFG81 Alternator: LSA 42.3 L9 Package Layout Review Engine

Page 19

- Similar design as G200 SII - Front doors (exhaust doors) with hinges for easier access

Package Layout Review

Exhaust system

Page 21: GIIIA Generators: G40 SIIIA and G60 SIIIA...Engine: Yanmar 4TNV98T-ZGGE Alternator: LSA 42.3 S5 G60 GIIIA unit Engine: JD 4045 HFG81 Alternator: LSA 42.3 L9 Package Layout Review Engine

Page 20

- Used as a channel in mid roof - Add steps and handle for easier access to lifting eye - Similar design of mounting to frame as SII – serial production

Package Layout Review

Lifting Bail

Page 22: GIIIA Generators: G40 SIIIA and G60 SIIIA...Engine: Yanmar 4TNV98T-ZGGE Alternator: LSA 42.3 S5 G60 GIIIA unit Engine: JD 4045 HFG81 Alternator: LSA 42.3 L9 Package Layout Review Engine

Page 21

- New design according to did not passed FAE analysis - Re-calculated before new analysis request, with good result

Package Layout Review

Lifting Bail – FAE analysis issue

Page 23: GIIIA Generators: G40 SIIIA and G60 SIIIA...Engine: Yanmar 4TNV98T-ZGGE Alternator: LSA 42.3 S5 G60 GIIIA unit Engine: JD 4045 HFG81 Alternator: LSA 42.3 L9 Package Layout Review Engine

Page 22

Package Layout Review

Electrical components – DC - No major differences on 12V DC system from SII design - Engine harness – braiding instead of conduit - Engine will be supplied with engine harness between sensors and ECU - Same battery as for G200 SII serial production - E-Stop button is the same and also on same position as on G200 SII serial production

Page 24: GIIIA Generators: G40 SIIIA and G60 SIIIA...Engine: Yanmar 4TNV98T-ZGGE Alternator: LSA 42.3 S5 G60 GIIIA unit Engine: JD 4045 HFG81 Alternator: LSA 42.3 L9 Package Layout Review Engine

Page 23

Package Layout Review

Power Pedestal – over view

- AC components will be from Schneider - Gauges on Analog panel will be from Schneider - Analog controller from Muprhy - Digital controller from ComAp (with dual freq.) - RCD use external toroid, due to grounding system and cost saving - New design of mail terminal buss bar - New design of sockets (included 32A and 63A in one set) - Access to mail buss bar and also to sockets from bottom of PP - Grounding system as a standard included Australian connection request (no cost increase) - Modularity

Page 25: GIIIA Generators: G40 SIIIA and G60 SIIIA...Engine: Yanmar 4TNV98T-ZGGE Alternator: LSA 42.3 S5 G60 GIIIA unit Engine: JD 4045 HFG81 Alternator: LSA 42.3 L9 Package Layout Review Engine

Page 24

Package Layout Review

Power Pedestal – socket option - 32A, 63A, two 16A sockets in one set - Two separate RCDs to avoid overload (300mA for 32A and 63A, 30mA for two 16A) - Ease mounting system (also possible in the field) - Access to socket from bottom with possibility of connection all socket in same time - Breakers supplied by Schneider - Sockets supplied by Scame

Page 26: GIIIA Generators: G40 SIIIA and G60 SIIIA...Engine: Yanmar 4TNV98T-ZGGE Alternator: LSA 42.3 S5 G60 GIIIA unit Engine: JD 4045 HFG81 Alternator: LSA 42.3 L9 Package Layout Review Engine

Page 25

Package Layout Review

Power Pedestal – main connection buss bar

- No wired connection between breaker and buss bar (cost saving, stronger design) -Better / easier access fro connection of main cables - Up to10 cables connection possibility

Page 27: GIIIA Generators: G40 SIIIA and G60 SIIIA...Engine: Yanmar 4TNV98T-ZGGE Alternator: LSA 42.3 S5 G60 GIIIA unit Engine: JD 4045 HFG81 Alternator: LSA 42.3 L9 Package Layout Review Engine

Page 26

Package Layout Review

Power Pedestal – main components

Page 28: GIIIA Generators: G40 SIIIA and G60 SIIIA...Engine: Yanmar 4TNV98T-ZGGE Alternator: LSA 42.3 S5 G60 GIIIA unit Engine: JD 4045 HFG81 Alternator: LSA 42.3 L9 Package Layout Review Engine

Page 27

Package Layout Review

Power Pedestal – how control panel will be connected to PP

- Connectors for control panel modularity

Page 29: GIIIA Generators: G40 SIIIA and G60 SIIIA...Engine: Yanmar 4TNV98T-ZGGE Alternator: LSA 42.3 S5 G60 GIIIA unit Engine: JD 4045 HFG81 Alternator: LSA 42.3 L9 Package Layout Review Engine

Page 28

Package Layout Review

Power Pedestal – control panels hinges

- Control panel will be placed to the PP on hinges

Page 30: GIIIA Generators: G40 SIIIA and G60 SIIIA...Engine: Yanmar 4TNV98T-ZGGE Alternator: LSA 42.3 S5 G60 GIIIA unit Engine: JD 4045 HFG81 Alternator: LSA 42.3 L9 Package Layout Review Engine

THANK YOU