    Getting Started with Chip Scope

    (reference

    http://www.xilinx.com/support/documentation/sw_manuals/chipscope_pro_sw_cores_10

    _1_ug029.pdf)

    This tutorial assumes that you have Verilog code with the ILA and ICON cores

    instantiated and have assigned ChipScopeData and ChipScopeTrig0 to useful signals.

    1. Run ChipScope Pro Analyzer

    http://www.xilinx.com/support/documentation/sw_manuals/chipscope_pro_sw_cores_10_1_ug029.pdfhttp://www.xilinx.com/support/documentation/sw_manuals/chipscope_pro_sw_cores_10_1_ug029.pdfhttp://www.xilinx.com/support/documentation/sw_manuals/chipscope_pro_sw_cores_10_1_ug029.pdfhttp://www.xilinx.com/support/documentation/sw_manuals/chipscope_pro_sw_cores_10_1_ug029.pdfhttp://www.xilinx.com/support/documentation/sw_manuals/chipscope_pro_sw_cores_10_1_ug029.pdf
  • 7/29/2019 Getting Started With Chips Cope

    2/12

    Z:\Home\cse465\Tools\GettingStartedWithChipScope.docPage 2 of 12

    2. Select JTAG Chain -> Xilinx Platform USB Cable

  • 7/29/2019 Getting Started With Chips Cope

    3/12

    Z:\Home\cse465\Tools\GettingStartedWithChipScope.docPage 3 of 12

    3. Click OK

    4. Click OK

  • 7/29/2019 Getting Started With Chips Cope

    4/12

    Z:\Home\cse465\Tools\GettingStartedWithChipScope.docPage 4 of 12

    5. Right click on DEV 2 and select Configure

  • 7/29/2019 Getting Started With Chips Cope

    5/12

    Z:\Home\cse465\Tools\GettingStartedWithChipScope.docPage 5 of 12

    6. Click on Select New File and browse to .bit file and click OK.

    7. Set the Trigger on Match Unit MO to XXXX_X111 to trigger on the 3 LSBs ofthe ChipScopeTrig0.

  • 7/29/2019 Getting Started With Chips Cope

    6/12

    Z:\Home\cse465\Tools\GettingStartedWithChipScope.docPage 6 of 12

    8. Collapse the DataPort vector into Busses by selecting a group of signals, rightclick on the signals and select Add to Bus -> New Bus.

    9. Right click on the Bus Name and select Rename.

  • 7/29/2019 Getting Started With Chips Cope

    7/12

    Z:\Home\cse465\Tools\GettingStartedWithChipScope.docPage 7 of 12

    10.Select the signals again, right click and select Remove From Viewer after the Busis created.

    11.When the Waveform window is formatted correctly, click the Run button.

  • 7/29/2019 Getting Started With Chips Cope

    8/12

    Z:\Home\cse465\Tools\GettingStartedWithChipScope.docPage 8 of 12

    12.When the trigger occurs the waveform will be displayed.

  • 7/29/2019 Getting Started With Chips Cope

    9/12

    Z:\Home\cse465\Tools\GettingStartedWithChipScope.docPage 9 of 12

    Generating ILA and ICON cores

    1. Run Project Navigator2. Right click on the project and select New Source3. Select IP (CORE Generator & Architecture Wizard)4. Set the File Name to icon5. Click Next.

    6. Select ICON (ChipScope ProIntegrated Controller) v1.03.a in theChipScope Pro folder in the Debug & Verification folder

    7. Click Next8. Click Finish

  • 7/29/2019 Getting Started With Chips Cope

    10/12

    Z:\Home\cse465\Tools\GettingStartedWithChipScope.docPage 10 of 12

    9. Click Finish10.Right click on the project and select New Source11.Select IP (CORE Generator & Architecture Wizard)12.Set the File Name to ila13.Click Next.

  • 7/29/2019 Getting Started With Chips Cope

    11/12

    Z:\Home\cse465\Tools\GettingStartedWithChipScope.docPage 11 of 12

    14.Select ILA (ChipScope ProIntegrated Logic Analyzer) v1.03.a in theChipScope Pro folder in the Debug & Verification folder

    15.Click Next16.Click Finish

    17.Uncheck Data Same As Trigger and set Data Port Width to 100 to store 512samples of 100 bits when a trigger occurs.

    18.Click Next

  • 7/29/2019 Getting Started With Chips Cope

    12/12

    Z:\Home\cse465\Tools\GettingStartedWithChipScope.docPage 12 of 12

    19.Set # Match Units to 2 and Match Type to Extended.20.Click Finish