4
Engine Make & Model: Perkins 2806A-E18TAG3 Circuit Breaker Type: 3 Pole ACB/MCCB Fuel Tank Capacity: litres (US gal) 1000 (264.2) Frequency: 50 Hz 60 Hz Fuel Consumption, Prime: l/hr (US gal/hr) - 138.4 (36.6) Engine Speed: RPM - 1800 Alternator Model: LL7024J Base Frame Type: Heavy Duty Fabricated Steel Fuel Consumption, Standby : l/hr (US gal/hr) - 155.6 (41.1) Output Ratings Generating Set Model Standby* - - 600.0 kW 750.0 kVA Prime* - - 540.0 kW 675.0 kVA 480V, 60 Hz - * Refer to ratings definitions on page 4. Ratings at power factor. GEP750-1 Technical Data Diesel Generator Set Exclusively from your Cat ® dealer Ratings at .8 power factor

Transcript of GEP750

Page 1: GEP750

Engine Make & Model: Perkins 2806A-E18TAG3

Circuit Breaker Type: 3 Pole ACB/MCCB

Fuel Tank Capacity: litres (US gal) 1000 (264.2)

Frequency: 50 Hz 60 Hz

Fuel Consumption, Prime: l/hr (US gal/hr) - 138.4 (36.6)

Engine Speed: RPM - 1800

Alternator Model: LL7024J

Base Frame Type: Heavy Duty Fabricated Steel

Fuel Consumption, Standby : l/hr (US gal/hr) - 155.6 (41.1)

Output Ratings

Generating Set Model Standby*

-

-

600.0 kW

750.0 kVA

Prime*

-

-

540.0 kW

675.0 kVA480V, 60 Hz

-

* Refer to ratings definitions on page 4. Ratings at power factor.0.8

GEP750-1

Technical Data

Diesel Generator SetExclusively from your Cat ® dealer

Ratings at .8 power factor

Page 2: GEP750

-

-

Air Filter Type:

Combustion Air Flow:

m³/min (cfm) -Standby:

-Prime:

Max. Combustion Air Intake

Restriction: kPa (in H2O)

Replaceable Element

47.6 (1681)-44.3 (1564)-

6.3 (25.3)Radiator Cooling Air Flow:

m³/min (cfm)External Restriction to

Cooling Air Flow: Pa (in H2O) 125 (0.5)-

804.0 (28393)

Air System 60 Hz50 Hz

Moment of Inertia: kg m² (lb. in²) 7.44 (25424)

Governing Type:

Governing Class:

Compression Ratio:

Displacement: l (cu.in)

Engine Electrical System:

-Voltage/Ground:

-Battery Charger Amps:

Weight: kg (lb) - Dry:

- Wet:

Cooling Method: WaterElectronic

ISO 8528 G214.5:1

18.1 (1104.5)

Bore/Stroke: mm (in) 145.0 (5.7)/183.0 (7.2)

24/Negative

702050 (4519)

2158 (4758)

Induction:

Manufacturer: Perkins

Model: 2806A-E18TAG3No. of Cylinders/Alignment: 6 / In Line

Cycle: 4 StrokeTurbocharged Air To Air

Charge Cooled

34.0Regenerative Power: kW-Prime: - 2270.0 (329.3)

2494.0 (361.7)--Standby:

BMEP: kPa (psi)

617.5 (828.0)- -Prime:

-Standby:

Gross Engine Power: kW (hp)

- 678.2 (909.0)

1800-Engine Speed: RPM

Oil Pan l (US gal):Total Oil Capacity l (US gal):Oil Filter Type:

Oil Type:

Cooling Method:

Eco, Full Flow55.5 (14.7)53.5 (14.1)

API CH4 / CI4Water

Prime

50 Hz -60 Hz 72.6 (19.2)103.3 (27.3)138.4 (36.6)155.3 (41.0)

---

(based on diesel fuel with a specific gravity of 0.85 and conforming to BS2869, Class A2)

Recommended Fuel:

Fuel Consumption: l/hr (US gal/hr)Class A2 Diesel

110%Load

75%Load

50%Load

100%Load

Fuel Filter Type: Eco Replaceable Element

Standby

50 Hz ---60 Hz 79.2 (20.9)114.7 (30.3)155.6 (41.1)

Level: dB

Silencer System: kPa (in Hg)Pressure Drop Across

Silencer Noise Reduction

Silencer Type:

Pressure: kPa (in. Hg)Max. Allowable Back

-Prime:

m³/min (cfm) -Standby:

Exhaust Gas Flow:

-Prime:

m³/min (cfm) -Standby:

Exhaust Gas Temperature: °C (°F)

SD200 (1)Silencer Noise Reduction

0.47 (0.139)-

10-

6.8 (2.0)-

143.0 (5050)-130.0 (4591)-

542 (1008)-513 (955)-

Level 1Cooling System Capacity:

l (US gal)Water Pump Type:

Heat Rejected to Water &

Lube Oil: kW (Btu/min) -Standby:

-Prime:

-Prime:

kW (Btu/min) -Standby:

Heat Radiation to Room:

Radiator Fan Load: kW (hp)

-

14.0 (18.8)

61.0 (16.1)-Centrifugal

170.9 (9719)163.9 (9321)-

45.6 (2593)-41.6 (2366)-

-

Cooling system designed to operate in ambient conditions up to 50°C (122°F). Contact your local Olympian dealer for power ratings at specific site conditions.

Cooling System 60 Hz50 Hz

Performance 60 Hz50 Hz

Fuel System

Exhaust System

Lubrication systemPhysical Data

Engine Techncial Data

Consult your Olympian representative for more information

60 Hz50 Hz

Page 3: GEP750

Data Item

50 Hz 60 Hz

Motor Starting Capability* kVA - - - - 1993 1283 - - 1694

Reactances: Per Unit

Xd

X'd

X''d

- - - - 2.840 4.530 - - 3.380

- - - - 0.140 0.220 - - 0.170

- - - - 0.111 0.178 - - 0.132

Reactances shown are applicable to standby ratings.* Based on 30% voltage dip.** With optional Permanent Magnet generator or AREP excitation.

480/277V 380/220V 440/254V220/127V

Short Circuit Capacity** % 300 300 300 300 300 300 300 300 300

Manufacturer:

Model:

No. of Bearings:

Insulation Class:

Winding Pitch - Code:

Wires:

Ingress Protection Rating:

Excitation System:

AVR Model:

LL7024J

1

H

2/3 - 6

12

IP23

AREP

R450

Overspeed: RPM

Voltage Regulation (steady state) (%):

Wave Form NEMA = TIF:

Wave Form IEC = THF:

Total Harmonic Content LL/LN:

Radio Interference:

Radiant Heat: kW (Btu/min)

-50 Hz:

-60 Hz:

Supression is in line with European Standard EN61000-6

42.6 (2423)

-

4.0%

2.0%

50

+/- 0.5

2250

Physical Data Operating Data

Alternator Performance Data

Alternator Technical Data

Consult your Olympian representative for more information

OLYMPIAN

Page 4: GEP750

kWkVAkWkVA

Technical Data Phase Ratings and Performance at 50 Hz, RPM-3

Voltage Prime Standby

Standby Rating

These ratings are applicable for supplying continuous electricalpower (at variable load) in the event of a utility power failure. Nooverload is permitted on these ratings. The alternator on this modelis peak continuous rated (as defined in ISO 8528-3).

Prime Rating

These ratings are applicable for supplying continuous electricalpower (at variable load) in lieu of commercially purchased power.There is no limitation to the annual hours of operation and thismodel can supply 10% overload power for 1 hour in 12 hours.

Standard Reference Conditions

Note: Standard reference conditions 25°C (77°F) air inlet temp,100m (328ft) A.S.L. 30% relative humidity. Fuel consumption dataat full load with diesel fuel with specific gravity of 0.85 andconforming to BS2869: 1998, Class A2.

Definitions

-

600.0750.0540.0675.0380/220V

600.0

600.0750.0540.0675.0480/277V

kW

-

750.0

kVAkW

540.0

-

675.0

kVA

440/254V

220/127V

-

Phase Ratings and Performance at 60 Hz, RPM18003

Voltage Prime Standby

Weights & Dimensions

Weights: kg (lb)

Net (+ lube oil)

Wet (+ lube oil & coolant)

Fuel, lube oil & coolant 6116 (13483)

4975 (10968)

4905 (10814)

Dimensions: mm (in)

Height

Width

Length

2246 (88.4)

1536 (60.5)

4111 (161.9)

Documents

A full set of operation and maintenance manuals and circuit wiring diagrams.

Quality Standards

BS4999, BS5000, BSEN60034, BSEN61000, IEC60034.

Warranty

All equipment carries full manufacturer's warranty.

General Data

Note: General configuration not to be usedfor installation. See general dimensiondrawings for detail.

Information contained in this publication may be considered confidential. www.Cat-ElectricPower.comMarket: International Discretion is recommended when distributing. Materials and specifications are subject to change without notice. © 2010 CaterpillarLEHF8849-01 (09/10) CAT, CATERPILLAR, their respective logos OLYMPIAN, "Caterpillar Yellow", and the "Power Edge" trade dress, as well as All rights reserved. corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission. Printed in U.S.A.278-687

LEHF8849-02 (09-10)

Information contained in this publication may be considered confidential. Discretion is recommended when distributing.

Materials and specifications are subject to change without notice.CAT, CATERPILLAR, their respective logos, OLYMPIAN, “Caterpillar Yellow,” the “Power Edge” trade dress as well as

corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission.