G2p Safety Readiness Review January 17, 2012 Expected Radiation Exposure Levels from Activated Local Dump George Kharashvili, Radiation Control

description

G2p Safety Readiness Review January 17, 2012 Expected Radiation Exposure Levels from Activated Local Dump. George Kharashvili , Radiation Control. Expected radiation exposure levels at beamline level 5 minutes after 5-day long - PowerPoint PPT Presentation

Transcript of George Kharashvili , Radiation Control

Page 1: George  Kharashvili , Radiation Control

G2p Safety Readiness ReviewJanuary 17, 2012

Expected Radiation Exposure Levels from Activated Local Dump

George Kharashvili, Radiation Control

Page 2: George  Kharashvili , Radiation Control

Expected radiation exposure levels at beamline level 5 minutes after 5-day long irradiation of the local dump for 20 hours per day with 100-nA, 3.35-GeV e- beam:

Page 3: George  Kharashvili , Radiation Control

15 minutes after the end of the run:

Page 4: George  Kharashvili , Radiation Control

30 minutes after the end of the run:

Page 5: George  Kharashvili , Radiation Control

Expected radiation exposure levels in the area adjacent to the local dump –This area will have to be accessed in order to replace the cartridge.

Page 6: George  Kharashvili , Radiation Control

15 minutes after the end of the run - dump cartridge has been replaced:

Page 7: George  Kharashvili , Radiation Control

30 minutes after the end of the run - dump cartridge has been replaced:

Page 8: George  Kharashvili , Radiation Control

1 hour after the end of the run - dump cartridge has been replaced:

Page 9: George  Kharashvili , Radiation Control

Expected radiation exposure levels at the floor level 5 minutes after 5-day long irradiation of the local dump for 20 hours per day with 100-nA, 3.35-GeV e- beam:

Page 10: George  Kharashvili , Radiation Control
Page 11: George  Kharashvili , Radiation Control
Page 12: George  Kharashvili , Radiation Control

Floor level 30 minutes after the end of the run - dump cartridge has been replaced:

Page 13: George  Kharashvili , Radiation Control

Expected radiation exposure levels 1m above the top platform 15 minutes after 5-day long irradiation of the local dump for 20 hours per day with 100-nA, 3.35-GeV e- beam:

Page 14: George  Kharashvili , Radiation Control
Page 15: George  Kharashvili , Radiation Control

Top platform 30 minutes after the end of the run - dump cartridge has been replaced:

Page 16: George  Kharashvili , Radiation Control

Conclusions:

• In general, radiation safety issues are expected to be comparable to a typical high current experiment;

• High Radiation Areas expected around the dump – physical access controls may be required;

• Radiation areas are expected in several meter radius around the local dump at the floor level and the top platform level;

• Routine access to target chamber at both platform levels will likely require a standing RWP.