General Purpose Transformers SOLAHEVI-DUT/ Y · HEVI-DUTY General Purpose Transformers Construction...

5
General Purpose Transformers SOLA/ HEVI-DUTY Selection Tables: Single Phase Group IA - 240 x 480 Volt Primary, 120/240 Secondary, 60 Hz (Encapsulated) Listed . Certified KVA .050 .075 .100 .150 .250 .500 .750 1 1.5 2 3 5 7.5 10 Catalog Number HS1B50 HS1B75 HS1B100 HS1B150 HS1B250 HS1F500B HS1F750B HS1F1BS HS1F1.5AS HS1F2AS HS5F3AS HS5F5AS HS5F7.5AS HS5F10AS Height (inch) 7 7 7 7.5 7.5 10 10 10 13 13 13 17 17 28 Width (inch) 4 4 4 5 5 6 6 6 10 10 10 14 14 14 Depth (inch) 3 3 3 4 4 5 5 5 7 7 7 9 9 9 Ship Weight Approx. (Ibs) 3 3 4 5 8 22 23 28 39 47 55 104 135 156 Design Style 2 2 2 2 2 3 3 3 4 4 4 4 4 4 Elec Conn 1 1 1 1 1 1 1 2 2 2 3 3 4 4 Primary Amps .208/.104 .31 21. 156 .417/.208 .625/.313 1.04/.512 2.08/1.04 3.13/1.56 4.17/2.08 6.25/3.13 8.33/4.17 12.5/6.25 20.8/10.4 31.3/15.6 41 .7/20.8 Secondary Amps .416/.208 .625/.312 .833/.417 1.25/.625 2.08/1.04 4.16/2.08 6.25/3.13 8.33/4.17 12.5/6.25 16.7/8.33 25.0/12.5 41 .6/20.8 62.5/31.3 83.3741. 7 Note: See Section 7 for Higher KVA encapsulated units. Group IB - 240 x 480 Volt Primary, 120/240 Secondary, 60 Hz KVA 15 25 37.5 50 75 100 167 250* Catalog Number S5H15S S5H25S S5H37S S5H50S S5H75S S5H100S S5H167S S5H250S NEMA3R Weather Shield WS-01 WS-15 WS-17 WS-17 WS-09 WS-09 WS-16 N/A Height (inch) 23 28 31 31 44 44 46 65 Width (inch) 14 16 18 18 23 23 26 36 Depth (inch) 16 16 18 18 21 21 24 35 Ship Weight Approx. (Ibs) 160 230 310 380 555 650 905 1580 Design Style 1 1 1 1 1 1 1 1 Elec Conn 5 5 5 5 5 5 5 5 Primary Amps 62.5/31.3 104/52.1 156/78 208/104 313/156 41 7/208 695/348 1042/521 •Secondary Amps 125/62.5 208/104 313/156 416/208 625/313 833/417 1 392/695 2083/1042 * Not UL or CSA Approved Group II - 120/208/240/277 Volt Primary, 120/240 Secondary, 60 Hz KVA 1 1.5 2 3 5 7.5 10 15 25 Catalog Number HS12F1BS HS12F1.5AS HS12F2AS HS12F3AS HS12F5AS HS12F7.5AS HS12F10AS S12H15S S12H25S NEMA3R Weather Shield N/A N/A N/A N/A N/A N/A N/A WS-01 WS-15 Height (inch) 10 13 13 13 17 17 17 23 28 Width (inch) 6 10 10 10 14 14 14 14 16 Depth (inch) 5 7 7 7 9 9 9 16 16 Ship Weight Approx. (Ibs) 29 40 60 66 104 135 156 200 250 Design Style 3 4 4 4 4 4 4 1 1 Elec Conn 9 10 10 10 10 10 10 11 11 Primary Amps* 3.6 5.4 7.2 10.8 18.0 27.1 36.1 54.2 90.3 Secondary Amps 8.33/4.17 12.5/6.25 16.7/8.33 25.0/12.5 41 .6/20.8 62.5/31.3 83.3/41.7 125/62.5 208/104 * Amperage calculated at 277 Volts on primary. Fax-on-Demand #: (877) 888-9329, Document #: 8332 72 Contact Technical Services at (800) 377-4384 with any questions.

Transcript of General Purpose Transformers SOLAHEVI-DUT/ Y · HEVI-DUTY General Purpose Transformers Construction...

Page 1: General Purpose Transformers SOLAHEVI-DUT/ Y · HEVI-DUTY General Purpose Transformers Construction Features • Free Shielding • Easy Installation • 10 Years+2 Warranty UL-3R

General Purpose Transformers SOLA/HEVI-DUTY

Selection Tables: Single PhaseGroup IA - 240 x 480 Volt Primary, 120/240 Secondary, 60 Hz (Encapsulated) Listed . Certified

KVA

.050

.075

.100

.150

.250

.500

.750

1

1.5

2

3

5

7.5

10

CatalogNumber

HS1B50

HS1B75

HS1B100

HS1B150

HS1B250

HS1F500B

HS1F750B

HS1F1BS

HS1F1.5AS

HS1F2AS

HS5F3AS

HS5F5AS

HS5F7.5AS

HS5F10AS

Height(inch)

7

7

7

7.5

7.5

10

10

10

13

13

13

17

17

28

Width(inch)

4

4

4

5

5

6

6

6

10

10

10

14

1 4

14

Depth(inch)

3

3

3

4

4

5

5

5

7

7

7

9

9

9

Ship WeightApprox. (Ibs)

3

3

4

5

8

22

23

28

39

47

55

104

135

156

DesignStyle

2

2

2

2

2

3

3

3

4

4

4

4

4

4

ElecConn

1

1

1

1

1

1

1

2

2

2

3

3

4

4

PrimaryAmps

.208/.104

.31 21. 156

.417/.208

.625/.313

1.04/.512

2.08/1.04

3.13/1.56

4.17/2.08

6.25/3.13

8.33/4.17

12.5/6.25

20.8/10.4

31.3/15.6

41 .7/20.8

SecondaryAmps

.416/.208

.625/.312

.833/.417

1.25/.625

2.08/1.04

4.16/2.08

6.25/3.13

8.33/4.17

12.5/6.25

16.7/8.33

25.0/12.5

41 .6/20.8

62.5/31.3

83.3741. 7

Note: See Section 7 for Higher KVA encapsulated units.

Group IB - 240 x 480 Volt Primary, 120/240 Secondary, 60 Hz

KVA

15

25

37.5

50

75

100

167

250*

CatalogNumber

S5H15S

S5H25S

S5H37S

S5H50S

S5H75S

S5H100S

S5H167S

S5H250S

NEMA3RWeatherShield

WS-01

WS-15

WS-17

WS-17

WS-09

WS-09

WS-16

N/A

Height(inch)

23

28

31

31

44

44

46

65

Width(inch)

14

16

18

18

23

23

26

36

Depth(inch)

16

16

18

18

21

21

24

35

Ship WeightApprox. (Ibs)

160

230

310

380

555

650

905

1580

DesignStyle

11111111

ElecConn

5

5

5

5

5

5

5

5

PrimaryAmps

62.5/31.3

104/52.1

156/78

208/104

313/156

41 7/208

695/348

1042/521

•SecondaryAmps

125/62.5

208/104

313/156

416/208

625/313

833/417

1 392/695

2083/1042

* Not UL or CSA Approved

Group II - 120/208/240/277 Volt Primary, 120/240 Secondary, 60 Hz

KVA

1

1.5

2

3

5

7.5

10

15

25

CatalogNumber

HS12F1BS

HS12F1.5AS

HS12F2AS

HS12F3AS

HS12F5AS

HS12F7.5AS

HS12F10AS

S12H15S

S12H25S

NEMA3RWeatherShield

N/A

N/A

N/A

N/A

N/A

N/A

N/A

WS-01

WS-15

Height(inch)

10

13

13

13

17

1 7

17

23

28

Width(inch)

6

10

10

10

14

14

14

14

16

Depth(inch)

5

7

7

7

9

9

9

16

16

Ship WeightApprox. (Ibs)

29

40

60

66

104

135

156

200

250

DesignStyle

3

4

4

4

4

4

4

1

1

ElecConn

9

10

10

10

10

10

10

1111

PrimaryAmps*

3.6

5.4

7.2

10.8

18.0

27.1

36.1

54.2

90.3

SecondaryAmps

8.33/4.17

12.5/6.25

16.7/8.33

25.0/12.5

41 .6/20.8

62.5/31.3

83.3/41.7

125/62.5

208/104

* Amperage calculated at 277 Volts on primary.Fax-on-Demand #: (877) 888-9329, Document #: 8332

72 Contact Technical Services at (800) 377-4384 with any questions.

Page 2: General Purpose Transformers SOLAHEVI-DUT/ Y · HEVI-DUTY General Purpose Transformers Construction Features • Free Shielding • Easy Installation • 10 Years+2 Warranty UL-3R

General Purpose Transformers

Listed Certified

Single Phase: .05-.250 KVA Features• UL-3R enclosure for indoor or

outdoor service.• Fast, easy installation.

Mounting holes built into theenclosure.

• Low temperature rise, ULclass 105°C insulationsystem, 55°C temperaturerise under full load. Can bebanked for three phase service.

• Nonmetallic nameplates listall rating data. Wiring diagramstrategically located oninside of wiring (Mlcompartment cover.

• Conduit knockouts for side entry into roomy wiringcompartment.

• Copper lead wire terminations.• Quiet operation.

Single Phase: .500-10 KVAThree Phase: 3-9 KVA Features

• UL-3R enclosures for indoor or outdoor service.• Fast, easy installation.• Electrostatically shielded for quality power on sizes

1 KVA and larger.• Efficient operation. UL class 180°C insulation system,

115°C temperature rise under full load. Can be bankedfor three phase service.

• Conduit knockouts for side entry into roomy wiringcompartment.

Design Styles

w

H

Style 1

• Copper lead wire terminations.• Units 1 -10 KVA are encapsulated with electrical grade

silica sand and epoxy for rugged applications.• Nonmetallic nameplates list all rating data. Wiring

diagram strategically located on inside of wiringcompartment cover.

Single Phase: 15-250 KVAThree Phase: 15-500 KVA Features

• UL class 220°C insulation system, 150°C temperaturerise under full load.

• Electrostatically shielded for quality power.• Front connected terminal board and spacious wiring

compartment.• UL-3R outdoor enclosures when used with optional

weather shields (order separately).• Panel enclosure design reduces labor time. Remove

only two bolts for entry. Wiring diagram on inside frontcover.

• Core and coil completely isolated from enclosure bymeans of vibration dampening pads to provide quietoperation.

Accessories and Design Styles• Wall mounting brackets - for ventilated design units,

single and three phase, 15 to 75 KVA. The catalognumber for all wall brackets is WB-1C.

• Totally enclosed non-ventilated designs are availablefor sizes 15 KVA and larger.

• Core and coil designs are available for sizes 15 KVAand larger.

• Surge Suppression Devices (page 5) provide additionalprotection and longevity to any electronic equipment.

• Weather Shields.

W

H

CD

Style 2

70Fax-on-Demand #: (877) 888-9329, Document #: 8331

Contact Technical Services at (800) 377-4384 with any questions.

Page 3: General Purpose Transformers SOLAHEVI-DUT/ Y · HEVI-DUTY General Purpose Transformers Construction Features • Free Shielding • Easy Installation • 10 Years+2 Warranty UL-3R

SOLA/HEVI-DUTY General Purpose Transformers

Construction Features

• Free Shielding• Easy Installation• 10 Years+2 Warranty

UL-3R EnclosuresFast Delivery

High impact powder paint finish

Remove two bolts forinterior access, frontor rear.

UL-3R Enclosure(with optional weathersrueld)

Large, easy to readwiring diagraminside front cover.

Shielded forquality power

Easily accessedtap connections.

Coils

Vibration and sounddampening pad.

Fiberglass terminalboard relieves cablestress.

Enclosure bottomdesigned for ventilationand rodent protection.

Flexible ground strap(included but not shown).

Fax-on-Demand #: (877) 888-9329, Document #: 8331Contact Technical Services at (800) 377-4384 with any questions. 71

Page 4: General Purpose Transformers SOLAHEVI-DUT/ Y · HEVI-DUTY General Purpose Transformers Construction Features • Free Shielding • Easy Installation • 10 Years+2 Warranty UL-3R

General Purpose Transformers

Electrical Connections (Single Phase)

240 X 480 Volt Primary120/240 Volt Secondary Taps: None

H1 H3 1

PrimaryVoltage

SecondaryVoltage

H1 to H3H2 to H4

X1 to X3X2 to X4

Connect Lines to

Connect Lines to

240 X 480 Volt Primary,120/240 Volt Secondary ATaps: 2, 21/2% FCAN; 4, 21/2% FCBN H1

H1 H2H3H4H5 H6H7H8H9 H10

LAJv-A-XJ UUJv-Aj

-L o^rVv ,̂ rv-vVv^~ ^xr

SHIELD I r-̂ S I

X1 X3 X2 X4

PrimaryVoltage

504

492

480

468

456

444

432

252

240

228

216

SecondaryVoltage

240

120/240

120

Interconnect

H5 to H6

H4 to H6

H4 to H7

H3 to H7

H3 to H8

H2 to H8

H2 to H9

H1 to H6H5to H10

H1 to H7H4to H10

H1 to H8H3to H10

H1 to H9H2to H10

Interconnect

X2 to X3

X2 to X3

X1 to X3X2 to X4

Connect Lines to

H1 & H10

H1 & H10

H1 & H10

H1 & H10

H1 & H10

H1 & H10

H1 & H10

H1 & H10

H1 & H10

H1 & H10

H1 & H10

Connect Lines to

X1 & X4

X 1 . X 2 & X 4

X1 &X4

240 X 480 Volt Primary120/240 Volt Secondary Taps: None

PrimaryVoltage

SecondaryVottage

120/240

Interconnect

H1 to H3H2 to H4

Interconnect

X1 to X3X2 to X4

Connect Lines to

Connect Lines to

X1 & X4

240 X 480 Volt Primary,1 20/240 Volt Secondary i*Taps: 2, 21/2% FCAN; 4, 21/2% FCBN **

H1 H2(1 0

7 5 3 1 2 4 6 8

^_A_/^^AAAA_AA>J V>^AAAAAAAAAA_.

\(' SHIELD

X1 X3 X2 X4

PrimaryVoltage

504

492

480

468

456

444

432

252

240

228

216

SecondaryVoltage

240

120/240

120

Interconnect

1 to 2

2 to 3

3 to 4

4 to 5

5 to 6

6 to 7

7 to 8

H1 to 2H2to1

H1 to 4H2to3

H1 to 6H2to5

H1 to 8H2to 7

Interconnect

X2 to X3

X2 to X3

X1 to X3X2 to X4

Connect Lines to

H1 & H2

H1 & H2

H1 & H2

H1 &H2

H1 & H2

H1 & H2

H1 & H2

H1 & H2

H1 & H2

H1 & H2

H1 & H2

Connect Lines to

X1 & X4

X 1 . X 2 & X 4

X1 &X4

240 X 480 Volt Primary 120/240 VoltSecondary Taps: 2, 21/2% FCAN & FCBN

3H1 H2 H3 H4 H5 H6 H7 H8

L>^A_A_X_A_X>J UV>LA_/LA^AJprv> r̂S^w~\ rv'YVv'V'w^ '1I r̂ S I SHIELD

X1 X3 X2 X4

PrimaryVoltage

504

492

480

468

456

252

240

228

SecondaryVoltage

240

120/240

120

Interconnect

H4 to H5

H3 to H5

H3 to H6

H2 to H6

H2 to H7

H1 to H5H4 to H8

H1 to H6H3 to H8

H1 to H7H2 to H8

Interconnect

X2 to X3

X2 to X3

X1 to X3X2 to X4

Connect Lines to

H1 & H8

H1 & H8

H1 & H8

H1 & H8

H1 & H8

H1 & H8

H1 & H8

H1 & H8

Connect Lines to

X1 & X4

X1 , X2 & X4

X1 & X4

600 VoltTaps: N

Ht

tX

Primary, 120/240 Volt Secoone

1 H• 4

>~A_A^A_^A-A^A_A^VAA-A--VA^

1 X3 X2 X

PrimaryVottage

600

SecondaryVoltage

240

120/240

120

Interconnect

Interconnect

X2 to X3

X2 to X3

X1 to X3X2 to X4

ndary

62i

i4

Connect Lines to

H1 & H2

Connect Lines to

X1 & X4

X 1 , X2& X4

X1 &X4

Note: 1 through 2 KVA units haveelectrostatic shielding.

78Fax-on-Demand #: (877) 888-

Contact Technical Services at (800)9329, Document #: 8334377-4384 with any questions.

Page 5: General Purpose Transformers SOLAHEVI-DUT/ Y · HEVI-DUTY General Purpose Transformers Construction Features • Free Shielding • Easy Installation • 10 Years+2 Warranty UL-3R

General Purpose Transformers SOLA/HEVI-DUTY

Specification Guide for Low Voltage, General Purpose,Dry Type Transformers (600 Volt Class) -15 KVA and larger

GeneralSingle and three phase distribution transformers(600 Volt and below)

• Provide and install, as referenced on the electricalplans, enclosed dry type transformers as manufacturedby Sola/Hevi-Duty or approved equal.

Standards• Transformers must be listed by Underwriters

Laboratory, certified with Canadian StandardsAssociation and designed, constructed and rated inaccordance with NEMA ST 20, ANSI C89.2 andapplicable IEEE & OSHA specifications.

ConstructionCores• All transformer cores shall be constructed of low loss,

high quality, electrical grade laminate steel. By design,the flux density is to be kept well below the saturationlevel to reduce audible sound level and minimize corelosses. The core volume shall allow operation at 10%above rated primary voltage at no load withoutexceeding the temperature rise of the unit.

Coils• Coil conductors shall be either aluminum or copper and

must be continuous. The entire core and coil assemblyshall be impregnated with a thermal setting varnish andcured to reduce hot spots in the coils and seal outmoisture. Coils with exposed magnet wire will not beacceptable. Transformers shall have common coreconstruction.

• All transformers shall incorporate a faraday(electrostatic) shield between primary and secondarywindings for the attenuation of voltage spikes, linenoise and voltage transients.

• Transformers shall be provided with six 2.5% fullcapacity taps - two above and four below primary ratedvoltage.

• General purpose transformers are classified asisolation transformers.

Enclosures• Transformer enclosures shall be constructed of heavy

gauge sheet steel and coated with a grey powder paintfinish (ANSI 61). Ventilated transformer enclosuresshall be UL/NEMA Type 2 rated and UL/NEMA Type3R rated for outdoor use with the addition of aweathershield. This information must be listed on thetransformer nameplate.

• Maximum transformer enclosure temperature willnot exceed 65°C rise above a 40°C ambient underfull load.

• Transformers must have vibration isolators locatedbetween the core and coil assembly and thetransformer enclosure to reduce audible sound levelscaused from magnetostriction of the transformer core.No externally located vibration dampening pads shallbe used as they tend to increase audible noise.Ventilated transformers are to be floor mounted to aconcrete pad.

• The transformer enclosure must be grounded by theinstaller in accordance with the latest edition of theNational Electric Code and any local codes orordinances.

Performance• Audible sound levels will not exceed limits established

in NEMA/ANSI Standard C89.2:

10 to 50 KVA 45 db51 to 150 KVA 50 db151 to 300 KVA 55 db301 to 500 KVA 60 db

• Transformers, 15 KVA to 500 KVA, shall incorporate aUL recognized 220°C insulation system and exhibit amaximum 150°C temperature rise above a maximumambient of 40°C under full load.

84Fax-on-Demand #: (877) 888-9329, Document #: 8336

Contact Technical Services at (800) 377-4384 with any questions.