GENERAL NOTES: SYMBOL LEGEND: CONTEXT SITE PLAN: CODE ...apps.kelowna.ca/CityPage/DevApps/Z20-0054...
Transcript of GENERAL NOTES: SYMBOL LEGEND: CONTEXT SITE PLAN: CODE ...apps.kelowna.ca/CityPage/DevApps/Z20-0054...
![Page 1: GENERAL NOTES: SYMBOL LEGEND: CONTEXT SITE PLAN: CODE ...apps.kelowna.ca/CityPage/DevApps/Z20-0054 Pinehurst Cr 1508.pdf · C K 4. 5 m M A I N G A R A E S E T B A C K 6. 0 m MAIN](https://reader033.fdocuments.in/reader033/viewer/2022052012/6027da6210c7813370554e2b/html5/thumbnails/1.jpg)
A101
1SIM
LOCATION OF SECTION DRAWING
BUILDING SECTION
SECTION NUMBER
WALL SECTION
DETAIL
SCALE:
1 View Name
1/8" = 1'-0"A102 A101
LOCATION OF FIRST OCCURANCE
LOCATION OF DETAIL DRAWING
DETAIL NUMBER
Door Tags
DOOR SIZE
Window Tags
WINDOW TYPE -SEE WINDOW DETAILS
Assembly Tags
ASSEMBLY TYPE -SEE CONSTRUCTION SCHEDULE
W1
1t
0' - 0" x 0' - 0"
LOCATION OF SECTION DRAWING
SECTION NUMBER
LOCATION OF DETAIL DRAWING
DETAIL NUMBER
designed
drawn
drawing title
drawing no.
project no.
project title
plotted
checked
scale
this document is:
Seal
Notes:© Copyright Reserved. This drawing and design is, and at all
times remains, the property of NOvation Architecture, and can be
reproduced only with written consent.
All drawings shall be read in conjunction with specifications and
consultant details.
All work shall be carried out in accordance with Canadian
standards, specifications, BC Building Code (2018 edition) and
local authority by-laws and regulations.
Tabulated scales refer to Arch D size drawings sheet.
This drawing must not be scaled.
Contractors shall verify all dimensions prior to commencement of
work.
Any omissions or discrepancies shall be reported to the architect.
NOT controlled. Revisions may be made without notice.
A CONTROLLED document. Revisions will be advised.
The first issue of the document.
A complete revision. Remove previous issues from use.
A partial revision. Remove previous issues of corresponding sheets / pages from use.
Not for Construction.
3 0 2 - 2 2 3 7 L E C K I E R O A D
K E L O W N A B C V 1 X 6 Y 5
Project File Name and Location:
SYMBOL LEGEND: CONTEXT SITE PLAN:GENERAL NOTES:
CONSULTANTS: DRAWING INDEX: ILLUSTRATION:
CODE ANALYSIS / ZONING:
6/25/2020 8:55:15 AM
1" = 1'-0"
\\SERVER1\shared\Novation Design Studio\Projects\2012_Pinehurst Carriage\Working Drawings\Revit\dwg\2012_Pinehurst Carriage.rte
2012
KA
PS
A0.00
COVER SHEET
PINEHURST CARRIAGE HOUSE
PS
1508 Pinehurst CR, Kelowna, British Columbia
ARCHITECTURAL DRAWING LIST
NO. NAMEA0.00 COVER SHEET
A1.00 SITE PLAN
A2.01 MAIN FLOOR PLAN
A2.03 ROOF PLAN
A3.00 EXTERIOR ELEVATIONS
A3.01 EXTERIOR ELEVATIONS
A3.02 SPACIAL SEPERATIONS
A3.03 WINDOW SCHEDULE
A4.00 BUILDING SECTIONS
GENERAL
1. ALL DIMENSIONS ARE MADE FROM EXTERIOR FACE OF WALL SHEATHING TO CENTER OF PARTY WALLS
AND INTERIOR WALLS UNLESS NOTED OTHERWISE ON PLANS. OUTSIDE EDGE OF EXTERIOR WALL
SHEATHING TO BE FLUSH WITH FOUNDATION WALL BELOW. DO NOT SCALE DRAWINGS. THE GENERAL
CONTRACTOR IS TO CHECK ALL DIMENSIONS AND CONFIRM ALL PROPERTY LINE BEARINGS AND DIMENSIONS
WITH LEGAL SURVEY.
2. IN THE CASE OF DISCREPANCY, THE ARCHITECT IS TO BE NOTIFIED BEFORE WORK CAN COMMENCE.
COMMENCEMENT OF CONSTRUCTION SHALL CONSTITUTE ACCEPTANCE OF CONDITIONS AS SATISFACTORY.
3. REFER TO MECHANICAL DRAWINGS FOR FINAL PLUMBING AND HVAC LAYOUT AND SPECIFICATIONS.
4. REFER TO ELECTRICAL DRAWINGS FOR FINAL LIGHT, OUTLETS AND ELECTRICAL PANEL LOCATIONS AND
SPEC.
5. REFER TO CIVIL DRAWINGS FOR OFFSITE CONSTRUCTION AND FINAL. SITE DRAINAGE LAYOUT AND SPEC.
6. REFER TO LANDSCAPE DRAWINGS FOR FINAL LANDSCAPE LAYOUT.
7. REFER TO STRUCTURAL DRAWINGS FOR FINAL WALL/FLOOR/ROOF/COLUMN LAYOUT AND SPECIFICATIONS.
ASSURANCE / COMPLIANCE REQUIREMENTS
1. THE CURRENT BCBC 2018, IT'S REQUIREMENTS AND ALL AGENDA, SHALL FORM AN INTEGRAL PART OF
THESE DRAWINGS. ALL CONSTRUCTION MATERIALS AND PROCEDURES SHALL CONFIRM TO THESE
STANDARDS.
2. ALL WORK TO CONFORM TO LOCAL BYLAWS AND DEVELOPMENT PERMIT REQUIREMENTS.
3. ALL DRAWINGS ARE TO BE READ AS A COMPLETE SET IN CONJUNCTION WITH SPECIFICATIONS AND CIVIL,
STRUCTURAL, MECHANICAL, ELECTRICAL, AND LANDSCAPE DRAWINGS AS APPLICABLE.
4. ALL WORK WILL BE SUBJECT TO FIELD REVIEW BY THE ARCHITECT AND OR OTHER REGISTERED
PROFESSIONAL AND BY THE CONSULTING ENGINEERS NAMED ON THESE DRAWINGS TO MEET THE
MUNICIPAL LETTERS OF ASSURANCE / COMPLIANCE REQUIREMENTS.
5. ALL WORK MUST MEET THE APPROVAL OF THE PROFESSIONAL CONSULTANTS.
6. ALL WORK MUST MEET THE STANDARDS OF THE B.C. TRADE ASSOCIATIONS GOVERNING EACH TRADE
INVOLVED IN THE PROJECT.
7. STARTING WORK ON THIS PROJECT BY ANY SUB-CONTRACTOR MEANS THAT THE ABOVE REQUIREMENTS
HAVE BEEN REVIEWED AND NO EXTRA CLAIM FOR COST WILL BE PUT FORWARD TO MEET THE
PROFESSIONAL CONSULTANTS FIELD REVIEW REQUIREMENTS.
8. THE SUB-CONTRACTORS ARE RESPONSIBLE FOR SITE SAFETY AND TO MEET ALL REQUIREMENTS OF THE
WORKERS COMPENSATION BOARD.
9. ALL SUB-CONTRACTORS WILL BE REQUIRE TO ACKNOWLEDGE COMPLIANCE WITH ABOVE CONDITIONS BY
SIGNING A COPY OF THESE REQUIREMENTS WHICH MUCH ACCOMPANY THEIR QUOTATION.
10. GENERAL CONTRACTOR IS TO KEEP RECORD AND PROVIDE ARCHITECT WITH COPIES OF MUNICIPAL
INSPECTION SLIPS.
11. THE CONTRACTOR / CLIENT IS TO INFORM THE ARCHITECT IN WRITING 24 HOURS PRIOR TO STARTING
CONSTRUCTION OF THE PROJECT.
12. THE SUB-CONTRACTOR IS TO CHECK ALL DIMENSIONS AFFECTING HIS TRADE AND IN THE CASE OF
DISCREPANCY THE CONTRACTOR IS TO BE NOTIFIED BEFORE WORK CAN COMMENCE.
13. THE CONTRACTOR IS TO NOTIFY THE ARCHITECT 24 HOURS PRIOR TO A REQUIRED INSPECTION.
ARCHITECTURALNOVATION ARCHITECTURE302-2237 LECKIE ROADKELOWNA, BC V1Y 9T1TEL. (236) 420-4144FAX. (250) 000-0000
Revisions
No. Date Description
1 20200623 IFBP
ENERGY ADVISORTOTAL HOME SOLUTIONS INCGilles Lesage, EA, AHI250-575-3015 cell778-477-6797 officewww.totalhome.
![Page 2: GENERAL NOTES: SYMBOL LEGEND: CONTEXT SITE PLAN: CODE ...apps.kelowna.ca/CityPage/DevApps/Z20-0054 Pinehurst Cr 1508.pdf · C K 4. 5 m M A I N G A R A E S E T B A C K 6. 0 m MAIN](https://reader033.fdocuments.in/reader033/viewer/2022052012/6027da6210c7813370554e2b/html5/thumbnails/2.jpg)
EXISTING HOUSE
EXISTING GARAGE / PROPOSED CARRIAGE HOUSE
PR
OP
ER
TY
LIN
E/
44.8
7 m
147
' -3"
PROPERTY LINE /22.91 m 75' - 2"
PR
OP
ER
TY
LIN
E/
43.3
8 m
142
' -4"
PROPERTY LINE/
23.06 m 75' - 8"
PINEHURST CRT.
MA
IN F
RO
NT
YA
RD
SE
BA
CK
4.5
m
MA
IN G
AR
AG
E S
ET
BA
CK
6.0
m
MAIN SIDE YARD SETBACK
2.0 m
MA
IN R
EA
R Y
AR
D S
ET
BA
CK
7.5
m
MAIN SIDE YARD SETBACK
3.0 mC
AR
RIA
GE
FR
ON
T S
ET
BA
CK
9.0
m
CARRIAGE REAR SETBACK
1.5 mCARRIAGE SIDE SETBACK
1.5 m
CA
RR
IAG
E R
EA
R S
ET
BA
CK
1.5
m
2.5 m
6.0
m
2.5 m
6.0
mEXISTING DRIVEWAY
ROOF OUTLINE
PARKING STALL
PARKING STALL
30m2 PRIVATE OPEN SPACE
30m
2P
RIV
AT
E O
PE
N S
PA
CE
1.0 m
LIT PATHWAY TO ENTRANCE
SP
AC
IAL
SE
TB
AC
K
2.7
m
PARKING STALL
2.5 m
6.0
m
5.4 m
1.0 m
designed
drawn
drawing title
drawing no.
project no.
project title
plotted
checked
scale
this document is:
Seal
Notes:© Copyright Reserved. This drawing and design is, and at all
times remains, the property of NOvation Architecture, and can be
reproduced only with written consent.
All drawings shall be read in conjunction with specifications and
consultant details.
All work shall be carried out in accordance with Canadian
standards, specifications, BC Building Code (2018 edition) and
local authority by-laws and regulations.
Tabulated scales refer to Arch D size drawings sheet.
This drawing must not be scaled.
Contractors shall verify all dimensions prior to commencement of
work.
Any omissions or discrepancies shall be reported to the architect.
NOT controlled. Revisions may be made without notice.
A CONTROLLED document. Revisions will be advised.
The first issue of the document.
A complete revision. Remove previous issues from use.
A partial revision. Remove previous issues of corresponding sheets / pages from use.
Not for Construction.
3 0 2 - 2 2 3 7 L E C K I E R O A D
K E L O W N A B C V 1 X 6 Y 5
Project File Name and Location:
6/25/2020 8:55:15 AM
1/8" = 1'-0"
\\SERVER1\shared\Novation Design Studio\Projects\2012_Pinehurst Carriage\Working Drawings\Revit\dwg\2012_Pinehurst Carriage.rte
2012
KA
PS
A1.00
SITE PLAN
PINEHURST CARRIAGE HOUSE
PS
1508 Pinehurst CR, Kelowna, British Columbia
Revisions
No. Date Description
1 20200623 IFBP
![Page 3: GENERAL NOTES: SYMBOL LEGEND: CONTEXT SITE PLAN: CODE ...apps.kelowna.ca/CityPage/DevApps/Z20-0054 Pinehurst Cr 1508.pdf · C K 4. 5 m M A I N G A R A E S E T B A C K 6. 0 m MAIN](https://reader033.fdocuments.in/reader033/viewer/2022052012/6027da6210c7813370554e2b/html5/thumbnails/3.jpg)
A3.01
2
A3.001A3.00 2
A3.01
1
ROOF LINE
BEDROOM
BA
TH
RO
OM
LIVING
MAIN ENTERANCE
x30" 80"
x32" 80"
KITCHEN
DINNING
2
A4.00
TV
REF
1'-6"
1'-4"
2'-
10 1
/2"
44x
84"
80"
45
7'-
8 5
/8"
1
1
2
2
A A
BB
A3.02
x3
0"
80"
x38" 80"
42
6'-
11 1
/2"
8'-
5 1
/2"
11'-7 1
/2"
7'-
9 1
/8"
19'-11 3/4"
LINEN
60" x 32"
19'-11 3/4"
23'-11 5
/8"
15'-0 3
/8"
8'-
11 1
/4"
4'-4 3/4"
5'-6 3/4" 2'-4 1/2" 12'-0 1/2"
8'-
11 1
/4"
12'-5 5
/8"
5'-
3 1
/4"
3'-8"
1'-0" 11'-0 1/2"
5'-6 3/4" 3'-4 1/2"
SD
CO
SD
CO
W3aW3a
W3a
W3a
W3a
W1
EF
1'-2"
x2
8"
80"
x30" 80"
2'-0"
STACK W/D
EXTERIOR WALL MOUNTED LIGHT
23'-5 1
/4"
3'-3 3/8"
3'-
8 3
/4"
3'-2"
2'-0"
4242
42
43
42
W1
W1
W1
2'-
6 3
/4"
43
10'-5" 8'-0 3/4" 1'-6"
4'-
6 1
/2"
4'-0" 4'-7"
CONCRETE STOOP
CONCRETE STOOP
2'-0 3/4"
A3.03 4
2
A8.00
WALL ASSEMBLIES
PLAN
ROOF ASSEMBLIES
SECTION
R1 - MAIN ROOF
ROOF 30 YEAR SHINGLES (EXISTING)2 LAYERS OF 30MIN ROOFING FELT OR APPROVED EQUIVALENT (EXISTING)7/16" SHEATHING (EXISTING)ROOF RAFTER SYSTEM (EXISTING)5 1/2" SPF6 MIL VAPOUT BARRIER1/2" GWB
W1 - EXTERIOR WALL
EXTERIOR FINISH (EXISTING)WATERPROOFING BUILDING PAPER (EXISTING)1/2" PLYWOOD SHEATHING (EXISTING)2x4 WOOD STUD (EXISTING)R14 ROXUL BATT1/2" GWB, TAPED AND FILLED
W3a - INTERIOR WALL
1/2" GWB, TAPED AND FILLED2x4 WOOD STUDSOUND BATT INSULATION (AS NOTED BELOW)1/2" GWB, TAPED AND FILLEDNOTE: BEDROOM TO BEDROOM WALLS, BATHROOM TO COMMON AREAS, BEDROOM TO COMMON AREAS TO BE INSULATED
REFER TO ENERGY ANALYSIS FOR RSI
designed
drawn
drawing title
drawing no.
project no.
project title
plotted
checked
scale
this document is:
Seal
Notes:© Copyright Reserved. This drawing and design is, and at all
times remains, the property of NOvation Architecture, and can be
reproduced only with written consent.
All drawings shall be read in conjunction with specifications and
consultant details.
All work shall be carried out in accordance with Canadian
standards, specifications, BC Building Code (2018 edition) and
local authority by-laws and regulations.
Tabulated scales refer to Arch D size drawings sheet.
This drawing must not be scaled.
Contractors shall verify all dimensions prior to commencement of
work.
Any omissions or discrepancies shall be reported to the architect.
NOT controlled. Revisions may be made without notice.
A CONTROLLED document. Revisions will be advised.
The first issue of the document.
A complete revision. Remove previous issues from use.
A partial revision. Remove previous issues of corresponding sheets / pages from use.
Not for Construction.
3 0 2 - 2 2 3 7 L E C K I E R O A D
K E L O W N A B C V 1 X 6 Y 5
Project File Name and Location:
6/25/2020 8:55:16 AM
1/2" = 1'-0"
\\SERVER1\shared\Novation Design Studio\Projects\2012_Pinehurst Carriage\Working Drawings\Revit\dwg\2012_Pinehurst Carriage.rte
2012
KA
PS
A2.01
MAIN FLOOR PLAN
PINEHURST CARRIAGE HOUSE
PS
1508 Pinehurst CR, Kelowna, British Columbia
1/2" = 1'-0"
Main Floor 479 SF1
Revisions
No. Date Description
1 20200623 IFBP
1/2" = 1'-0"
Assemblies
![Page 4: GENERAL NOTES: SYMBOL LEGEND: CONTEXT SITE PLAN: CODE ...apps.kelowna.ca/CityPage/DevApps/Z20-0054 Pinehurst Cr 1508.pdf · C K 4. 5 m M A I N G A R A E S E T B A C K 6. 0 m MAIN](https://reader033.fdocuments.in/reader033/viewer/2022052012/6027da6210c7813370554e2b/html5/thumbnails/4.jpg)
1
1
2
2
A A
BB
5" / 12" 5" / 12"
5"
/ 12"
5"
/ 12"
1'-7 1/4"
1'-
7 1
/4"
1'-7 1/4"
1'-
7 1
/4"
23'-2 1/4"
27'-2 1
/8"
R1a
2
A8.00
designed
drawn
drawing title
drawing no.
project no.
project title
plotted
checked
scale
this document is:
Seal
Notes:© Copyright Reserved. This drawing and design is, and at all
times remains, the property of NOvation Architecture, and can be
reproduced only with written consent.
All drawings shall be read in conjunction with specifications and
consultant details.
All work shall be carried out in accordance with Canadian
standards, specifications, BC Building Code (2018 edition) and
local authority by-laws and regulations.
Tabulated scales refer to Arch D size drawings sheet.
This drawing must not be scaled.
Contractors shall verify all dimensions prior to commencement of
work.
Any omissions or discrepancies shall be reported to the architect.
NOT controlled. Revisions may be made without notice.
A CONTROLLED document. Revisions will be advised.
The first issue of the document.
A complete revision. Remove previous issues from use.
A partial revision. Remove previous issues of corresponding sheets / pages from use.
Not for Construction.
3 0 2 - 2 2 3 7 L E C K I E R O A D
K E L O W N A B C V 1 X 6 Y 5
Project File Name and Location:
NOT FOR CONSTRUCTION
6/25/2020 8:55:16 AM
1/2" = 1'-0"
\\SERVER1\shared\Novation Design Studio\Projects\2012_Pinehurst Carriage\Working Drawings\Revit\dwg\2012_Pinehurst Carriage.rte
2012
KA
PS
A2.03
ROOF PLAN
PINEHURST CARRIAGE HOUSE
PS
1508 Pinehurst CR, Kelowna, British Columbia
Revisions
No. Date Description
1/2" = 1'-0"
Roof Plan1
![Page 5: GENERAL NOTES: SYMBOL LEGEND: CONTEXT SITE PLAN: CODE ...apps.kelowna.ca/CityPage/DevApps/Z20-0054 Pinehurst Cr 1508.pdf · C K 4. 5 m M A I N G A R A E S E T B A C K 6. 0 m MAIN](https://reader033.fdocuments.in/reader033/viewer/2022052012/6027da6210c7813370554e2b/html5/thumbnails/5.jpg)
Main Floor 479 SF
838' - 4 3/4"
TOP PLATE
846' - 1 1/4"
2
A4.00
AB
R1a
23'-11 5/8"
7'-
8 1
/2"
W1
3.1
m
3.2
m
MID-PIONT
5"
12"
5"
12"
CONCRETE STOOP
6"
ENTERANCE LIGHT FIXTURE
2
A8.00
Main Floor 479 SF
838' - 4 3/4"
TOP PLATE
846' - 1 1/4"
2
A4.00
A B
R1a
W1
23'-11 5/8"
7'-
8 1
/2"
6'-11"
6'-8"
MID-PIONT
3.2
m
3.1
m
5"
12"
5"
12"
CONCRETE STOOP
6"
2
A8.00
designed
drawn
drawing title
drawing no.
project no.
project title
plotted
checked
scale
this document is:
Seal
Notes:© Copyright Reserved. This drawing and design is, and at all
times remains, the property of NOvation Architecture, and can be
reproduced only with written consent.
All drawings shall be read in conjunction with specifications and
consultant details.
All work shall be carried out in accordance with Canadian
standards, specifications, BC Building Code (2018 edition) and
local authority by-laws and regulations.
Tabulated scales refer to Arch D size drawings sheet.
This drawing must not be scaled.
Contractors shall verify all dimensions prior to commencement of
work.
Any omissions or discrepancies shall be reported to the architect.
NOT controlled. Revisions may be made without notice.
A CONTROLLED document. Revisions will be advised.
The first issue of the document.
A complete revision. Remove previous issues from use.
A partial revision. Remove previous issues of corresponding sheets / pages from use.
Not for Construction.
3 0 2 - 2 2 3 7 L E C K I E R O A D
K E L O W N A B C V 1 X 6 Y 5
Project File Name and Location:
6/25/2020 8:55:19 AM
1/2" = 1'-0"
\\SERVER1\shared\Novation Design Studio\Projects\2012_Pinehurst Carriage\Working Drawings\Revit\dwg\2012_Pinehurst Carriage.rte
2012
KA
PS
A3.00
EXTERIOR ELEVATIONS
PINEHURST CARRIAGE HOUSE
PS
1508 Pinehurst CR, Kelowna, British Columbia
1/2" = 1'-0"
East1
1/2" = 1'-0"
West2
Revisions
No. Date Description
1 20200623 IFBP
![Page 6: GENERAL NOTES: SYMBOL LEGEND: CONTEXT SITE PLAN: CODE ...apps.kelowna.ca/CityPage/DevApps/Z20-0054 Pinehurst Cr 1508.pdf · C K 4. 5 m M A I N G A R A E S E T B A C K 6. 0 m MAIN](https://reader033.fdocuments.in/reader033/viewer/2022052012/6027da6210c7813370554e2b/html5/thumbnails/6.jpg)
Main Floor 479 SF
838' - 4 3/4"
TOP PLATE
846' - 1 1/4"
7'-
8 1
/2"
1
A4.00
1 2
R1a
W1
19'-11 3/4"
MID-PIONT
3.2
m
3.1
m
5"
12"
5"
12"
CONCRETE STOOP
6"
ENTERANCE LIGHT FIXTURE
CONCRETE STOOP
6"
Main Floor 479 SF
838' - 4 3/4"
TOP PLATE
846' - 1 1/4"
1
A4.00
12
19'-11 3/4"
7'-
8 1
/2"
W1
R1a
W1
MID-PIONT
3.2
m
3.1
m
5"
12"
5"
12"
CONCRETE STOOP
6"
designed
drawn
drawing title
drawing no.
project no.
project title
plotted
checked
scale
this document is:
Seal
Notes:© Copyright Reserved. This drawing and design is, and at all
times remains, the property of NOvation Architecture, and can be
reproduced only with written consent.
All drawings shall be read in conjunction with specifications and
consultant details.
All work shall be carried out in accordance with Canadian
standards, specifications, BC Building Code (2018 edition) and
local authority by-laws and regulations.
Tabulated scales refer to Arch D size drawings sheet.
This drawing must not be scaled.
Contractors shall verify all dimensions prior to commencement of
work.
Any omissions or discrepancies shall be reported to the architect.
NOT controlled. Revisions may be made without notice.
A CONTROLLED document. Revisions will be advised.
The first issue of the document.
A complete revision. Remove previous issues from use.
A partial revision. Remove previous issues of corresponding sheets / pages from use.
Not for Construction.
3 0 2 - 2 2 3 7 L E C K I E R O A D
K E L O W N A B C V 1 X 6 Y 5
Project File Name and Location:
6/25/2020 8:55:21 AM
1/2" = 1'-0"
\\SERVER1\shared\Novation Design Studio\Projects\2012_Pinehurst Carriage\Working Drawings\Revit\dwg\2012_Pinehurst Carriage.rte
2012
KA
PS
A3.01
EXTERIOR ELEVATIONS
PINEHURST CARRIAGE HOUSE
PS
1508 Pinehurst CR, Kelowna, British Columbia
1/2" = 1'-0"
South1
1/2" = 1'-0"
North2
Revisions
No. Date Description
1 20200623 IFBP
![Page 7: GENERAL NOTES: SYMBOL LEGEND: CONTEXT SITE PLAN: CODE ...apps.kelowna.ca/CityPage/DevApps/Z20-0054 Pinehurst Cr 1508.pdf · C K 4. 5 m M A I N G A R A E S E T B A C K 6. 0 m MAIN](https://reader033.fdocuments.in/reader033/viewer/2022052012/6027da6210c7813370554e2b/html5/thumbnails/7.jpg)
Main Floor 479 SF
838' - 4 3/4"
TOP PLATE
846' - 1 1/4"
Top Of Footings
836' - 1 3/4"
A B
LIMITED DISTANCE AREA = 16.8m2
LIMITED DISTANCE = 14.3 m
ALLOWABLE = 100%
GLAZING AREA ALLOWED =16.8m2
GLAZING AREA = 6.1 m2
ACTUAL = 36.3%
Main Floor 479 SF
838' - 4 3/4"
TOP PLATE
846' - 1 1/4"
Top Of Footings
836' - 1 3/4"
AB
LIMITED DISTANCE AREA = 15.8 m2
LIMITED DISTANCE = 2.4 m
ALLOWABLE = 17.4%
GLAZING AREA ALLOWED =2.8 m2
GLAZING AREA = 1.04 m2
ACTUAL = 6.6%
Main Floor 479 SF
838' - 4 3/4"
TOP PLATE
846' - 1 1/4"
Top Of Footings
836' - 1 3/4"
12
LIMITED DISTANCE AREA = 14m2
LIMITED DISTANCE = 2.6m
ALLOWABLE = 20.1%
GLAZING AREA ALLOWED = 2.8m2
GLAZING AREA = 0.7m2
ACTUAL = 5%
designed
drawn
drawing title
drawing no.
project no.
project title
plotted
checked
scale
this document is:
Seal
Notes:© Copyright Reserved. This drawing and design is, and at all
times remains, the property of NOvation Architecture, and can be
reproduced only with written consent.
All drawings shall be read in conjunction with specifications and
consultant details.
All work shall be carried out in accordance with Canadian
standards, specifications, BC Building Code (2018 edition) and
local authority by-laws and regulations.
Tabulated scales refer to Arch D size drawings sheet.
This drawing must not be scaled.
Contractors shall verify all dimensions prior to commencement of
work.
Any omissions or discrepancies shall be reported to the architect.
NOT controlled. Revisions may be made without notice.
A CONTROLLED document. Revisions will be advised.
The first issue of the document.
A complete revision. Remove previous issues from use.
A partial revision. Remove previous issues of corresponding sheets / pages from use.
Not for Construction.
3 0 2 - 2 2 3 7 L E C K I E R O A D
K E L O W N A B C V 1 X 6 Y 5
Project File Name and Location:
6/25/2020 8:55:22 AM
3/8" = 1'-0"
\\SERVER1\shared\Novation Design Studio\Projects\2012_Pinehurst Carriage\Working Drawings\Revit\dwg\2012_Pinehurst Carriage.rte
2012
KA
PS
A3.02
SPACIAL SEPERATIONS
PINEHURST CARRIAGE HOUSE
PS
1508 Pinehurst CR, Kelowna, British Columbia
3/8" = 1'-0"
West- Spacial1
3/8" = 1'-0"
East Spacial4
3/8" = 1'-0"
North Spacial2
Revisions
No. Date Description
1 20200623 IFBP
![Page 8: GENERAL NOTES: SYMBOL LEGEND: CONTEXT SITE PLAN: CODE ...apps.kelowna.ca/CityPage/DevApps/Z20-0054 Pinehurst Cr 1508.pdf · C K 4. 5 m M A I N G A R A E S E T B A C K 6. 0 m MAIN](https://reader033.fdocuments.in/reader033/viewer/2022052012/6027da6210c7813370554e2b/html5/thumbnails/8.jpg)
MFE
42
6'-8"
1'-6"
5'-2"
1'-6"
MFE
6'-8"
3'-6"
3'-2"
1'-3"
1'-3"
39
OPAQUE
MFE
45
6'-8"
2'-6"
2'-6"
3'-0"
3'-8"
MFE
44
6'-8"
3'-0"
3'-8"
2'-0"
designed
drawn
drawing title
drawing no.
project no.
project title
plotted
checked
scale
this document is:
Seal
Notes:© Copyright Reserved. This drawing and design is, and at all
times remains, the property of NOvation Architecture, and can be
reproduced only with written consent.
All drawings shall be read in conjunction with specifications and
consultant details.
All work shall be carried out in accordance with Canadian
standards, specifications, BC Building Code (2018 edition) and
local authority by-laws and regulations.
Tabulated scales refer to Arch D size drawings sheet.
This drawing must not be scaled.
Contractors shall verify all dimensions prior to commencement of
work.
Any omissions or discrepancies shall be reported to the architect.
NOT controlled. Revisions may be made without notice.
A CONTROLLED document. Revisions will be advised.
The first issue of the document.
A complete revision. Remove previous issues from use.
A partial revision. Remove previous issues of corresponding sheets / pages from use.
Not for Construction.
3 0 2 - 2 2 3 7 L E C K I E R O A D
K E L O W N A B C V 1 X 6 Y 5
Project File Name and Location:
6/25/2020 8:55:23 AM
1 1/2" = 1'-0"
\\SERVER1\shared\Novation Design Studio\Projects\2012_Pinehurst Carriage\Working Drawings\Revit\dwg\2012_Pinehurst Carriage.rte
2012
KA
PS
A3.03
WINDOW SCHEDULE
PINEHURST CARRIAGE HOUSE
PS
1508 Pinehurst CR, Kelowna, British Columbia
Revisions
No. Date Description
1 20200623 IFBP
![Page 9: GENERAL NOTES: SYMBOL LEGEND: CONTEXT SITE PLAN: CODE ...apps.kelowna.ca/CityPage/DevApps/Z20-0054 Pinehurst Cr 1508.pdf · C K 4. 5 m M A I N G A R A E S E T B A C K 6. 0 m MAIN](https://reader033.fdocuments.in/reader033/viewer/2022052012/6027da6210c7813370554e2b/html5/thumbnails/9.jpg)
Main Floor 479 SF
838' - 4 3/4"
TOP PLATE
846' - 1 1/4"
2
A4.00
Top Of Footings
836' - 1 3/4"
A4.00
3
AB
2.5" XPS OR 3" EPS
EXISTING SLAB
SPRAY FOAM
23'-11 5/8"
9'-
11 1
/2"
7'-
8 1
/2"
2'-3"
W1W1
R1a
7'-
1 5
/8"
5"
12"5"
12"
24'-1 1/8"
2
A8.00
Main Floor 479 SF
838' - 4 3/4"
TOP PLATE
846' - 1 1/4"
1
A4.00
Top Of Footings
836' - 1 3/4"
1 2
W1
7'-
8 1
/2"
2.5" XPS OR 3" EPS
EXISTING SLAB
R1a
19'-11 3/4"
7'-
8 1
/2"
2'-3"
9'-
11 1
/2"
CONCRETE STOOP
5"
12"
5"
12"
SPRAY FOAM R-44 INSULATION
FASCIA
ASPHALT SHINGLE
FLASHING
VENTED SOFFIT
GUTTER
REFER TO PLANS
GL
R1
W1
designed
drawn
drawing title
drawing no.
project no.
project title
plotted
checked
scale
this document is:
Seal
Notes:© Copyright Reserved. This drawing and design is, and at all
times remains, the property of NOvation Architecture, and can be
reproduced only with written consent.
All drawings shall be read in conjunction with specifications and
consultant details.
All work shall be carried out in accordance with Canadian
standards, specifications, BC Building Code (2018 edition) and
local authority by-laws and regulations.
Tabulated scales refer to Arch D size drawings sheet.
This drawing must not be scaled.
Contractors shall verify all dimensions prior to commencement of
work.
Any omissions or discrepancies shall be reported to the architect.
NOT controlled. Revisions may be made without notice.
A CONTROLLED document. Revisions will be advised.
The first issue of the document.
A complete revision. Remove previous issues from use.
A partial revision. Remove previous issues of corresponding sheets / pages from use.
Not for Construction.
3 0 2 - 2 2 3 7 L E C K I E R O A D
K E L O W N A B C V 1 X 6 Y 5
Project File Name and Location:
6/25/2020 8:55:23 AM
As indicated
\\SERVER1\shared\Novation Design Studio\Projects\2012_Pinehurst Carriage\Working Drawings\Revit\dwg\2012_Pinehurst Carriage.rte
2012
KA
PS
A4.00
BUILDING SECTIONS
PINEHURST CARRIAGE HOUSE
PS
1508 Pinehurst CR, Kelowna, British Columbia
1/2" = 1'-0"
Section 21
1/2" = 1'-0"
Section 12
1 1/2" = 1'-0"
ROOF OVERHANG3
Revisions
No. Date Description
1 20200623 IFBP