ANCHOR BOLT NUT TIGHTENING PROCEDURE:SET AND PLUMB THE COLUMN, PER AISC ERECTION PROVISIONS, WITH DOUBLE NUTS ON THEREQUIRED NUMBER OF ANCHOR BOLTS. THE BOTTOM NUT SHALL HAVE A FLAT WASHER BETWEENTHE BOTTOM OF BASEPLATE AND THE TOP OF THE NUT. THE TOP NUT SHALL HAVE A WASHERBETWEEN THE TOP OF BASEPLATE AND THE BOTTOM OF THE NUT. AFTER THE COLUMNIS SET AND PLUMB, TIGHTEN THE TOP NUT TO A SNUG TIGHT CONDITION WITH TOP OF THEBASEPLATE (FULL EFFORT OF A MAN ON A WRENCH).
RETURN FOR FABRICATION OF CANOPY
PLEASE REVIEW ALL DRAWINGS, SIGN AND
SITE CONDITIONS / REQUIREMENTS
FINAL APPROVED PLAN
KICK OFF MEETING
ISSUED FOR 50%
ISSUED FOR PERMIT
ISSUED FOR 90%
ISSUED FOR BID
REVISIONS BYDATE
GIANT EAGLE, INC.
261 KAPPA DRIVE
PITTSBURGH, PA 15238
REV.
NO.
SPCR
NO.
GET GO FUEL STATION #
FC-
FOUNDATION PLAN
AETOS CONSTRUCTION CO.
I-90 & SR 430
ERIE, PA 16510 (ERIE)
3090
12/18/14
DWG
101
51057 P051057
1/8"=1'-0"
PROFESSIONAL ENGINEERLAWRENCE R. PILON
ANALYSIS - EQUIVALENT LATERAL FORCE PROCEDURE
Wind Importance Factor- I = 1.0 (Category II)
Response Modification Coefficient - R = 2System Overstrength Factor - o = 2Deflection Amplification Factor - Cd = 2
INVERTED PENDULUM SYSTEMBASIC SEISMIC - FORCE - RESISTING SYSTEM -
Internal Pressure Coefficients - GCpi = 0.00 (Open Bldg.)
BE FORMED FROM MATERIAL HAVING A 50 KSI MINIMUM TO ASTM A653 AND ASTM C-955. ALL MEMBERS SHALL
4) LIGHT GAUGE COLD FORMED SHAPES SHALL CONFORM
PER ALL AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)1) ERECTION OF STEEL STRUCTURE SHALL BE PERFORMED
Structural Pipe - ASTM A500, Grade B, Fy = 42 KSIStructural Tubing - ASTM A500, Grade B, Fy = 46 KSIStructural Plate - ASTM A572, Grade 50, Fy = 50 KSIStructural Angle and Channel - ASTM A36, Fy = 36 KSIWide Flange Beams - ASTM A992, Grade 50, Fy = 50 KSI
STEEL DEFORMED BARS CONFORMING TO ASTM A615,OF 145 PCF. REINFORCING STEEL SHALL BE NEW BILLET28 DAYS OF 3000 PSI AND A MINIMUM UNIT WEIGHTSHALL HAVE A MINIMUM COMPRESSIVE STRENGTH ATREINFORCED CONCRETE", (ACI 318-08). ALL CONCRETEWITH ACI "BUILDING CODE REQUIREMENTS FOR
2) ALL CONCRETE WORK SHALL BE PERFORMED IN ACCORDANCE
BE TIGHTENED PER AISC TURN OF THE NUT METHOD.STRUCTURAL STEEL CONNECTIONS. BOLTS SHALL
GENERAL NOTES:
5) BOLTS SHALL CONFORM TO ASTM A325 FOR
6) MINIMUM REQUIRED SOIL BEARING PRESSURE OF
SEISMIC RESPONSE COEFFICIENT - Cs =
W
SSnow Importance Factor- I = 1.0 (Category II)
Roof Snow Load (ASCE 7-05):
S
CANTILEVERED COLUMN SYSTEM
Mapped Spectral Response Accelerations At 1-Sec. Period - S1= gMapped Spectral Response Accelerations At Short Periods - S = gOccupancy Category- II
SEISMIC LOAD : (ASCE 7-05)
Wind Exposure - ' B '
Basic Wind Speed (3-Sec. Gust) - V =
Thermal Factor- Ct= 1.2
Snow Exposure Factor- Ce = 1.0Flat Roof Snow Load- Pf =
YIELD STRENGTH.
ERECTION PROVISIONS.
Roof Live Load =
SHALL BE PROVIDED BY THE OWNER.
GRADE 60.3) STRUCTURAL STEEL SHALL CONFORM TO:
7) DESIGN CRITERIA-
Wind Load (ASCE 7-05) :
FURNISHED BY McGEE CORP.8) A307 ANCHOR BOLTS & WOOD TEMPLATES SHALL BE
MAY BE GREATER THAN BUT NOT LESS THAN
BY AN AWS CERTIFIED WELDER.ELECTRODES. ALL WELDING SHALL BE PERFORMEDWITH LATEST AWS SPECIFICATIONS, USING E70XX
12) ALL WELDED CONNECTIONS SHALL BE IN ACCORDANCE
CONFLICT. WHERE FOUNDATION DETAIL IS NOT SHOWNMcGEE CORPORATION AND THEIR ENGINEERS TAKE NORESPONSIBILITY FOR FOUNDATION DESIGN.
OF RECORD SHALL BE NOTIFIED PRIOR TO CONSTRUCTIONDETRIMENTAL TO THEIR PROPER FUNCTION. THE ENGINEER
OF FOUNDATIONS FOR THE RESOLUTION OF ANY
OR OTHER NEARBY OBSTRUCTIONS THAT WOULD BEDESIGN ASSUMES THAT THERE ARE NO BURIED TANKSGIVEN LOADS AND ALLOWABLE SOIL PRESSURE. THEIR
11) FOUNDATIONS (WHERE SHOWN) HAVE BEEN SIZED FORMAINTENANCE ARE THE RESPONSIBILITY OF THE OWNER.ONLY. FIELD TOUCH-UP, FINISH PAINTING ANDTO EXTERIOR EXPOSURE HAS BEEN PRIMED COATED
10) STRUCTURAL AND MISCELLANEOUS STEEL SUBJECTED
GRADE ELEVATION.BELOW THE PREVIOUSLY DETERMINED LOWEST FINISHED
BOX INSTALLATION. TOP OF FOUNDATION DEPTHTO ENSURE FOUNDATION DOES NOT INTERFERE WITHVERIFY FUEL CONTAINMENT BOX SIZE AND LOCATIONIN RELATION TO THAT ELEVATION. CONTRACTOR MUSTLOWEST AND ESTABLISH ALL FOUNDATION LOCATIONSGRADE ELEVATION AT EACH CANOPY COLUMN IS THECONTRACTOR SHALL DETERMINE WHICH FINISHED
9) CANOPY FOUNDATION INSTALLATION:
Ground Snow Load- Pg =
Seismic Importance Factor - le= 1.00 (Category II)
Site Class - Design Spectral Response Acceleration At Short Periods - S = gDesign Spectral Response Acceleration At 1-Sec. Period - S = g
DS
D1
SEISMIC DESIGN CATEGORY -
SEISMIC BASE SHEAR - V =
- Fv = - Fa =
Lateral =Uplift =
2009 PA BUILDING CODE (2009 IBC)
100 MPH
B
0.050.18
40 PSF
40 PSF
2000 PSF
0.096
40 PSF
D ASSUMED
0.080.192
1.2 KIPS / COLUMN
12"
2.41.6
25 PSF20 PSF
A
DWG
A
01-13-15
1/15/15
-
FINAL APPROVED PLAN
KICK OFF MEETING
ISSUED FOR 50%
ISSUED FOR PERMIT
ISSUED FOR 90%
ISSUED FOR BID
REVISIONS BYDATE
GIANT EAGLE, INC.
261 KAPPA DRIVE
PITTSBURGH, PA 15238
REV.
NO.
SPCR
NO.
GET GO FUEL STATION #
FC-
ROOF PLAN & DETAILS
AETOS CONSTRUCTION CO.
I-90 & SR 430
ERIE, PA 16510 (ERIE)
3090
12/18/14
DWG
102
51057 P051057A
1/8"=1'-0"
PROFESSIONAL ENGINEERLAWRENCE R. PILON
A A
DWG
A
01-13-15
-
FINAL APPROVED PLAN
KICK OFF MEETING
ISSUED FOR 50%
ISSUED FOR 90%
ISSUED FOR BID
PROFESSIONAL ENGINEERLAWRENCE R. PILON
ISSUED FOR PERMIT
REVISIONS BYDATE
GIANT EAGLE, INC.
261 KAPPA DRIVE
PITTSBURGH, PA 15238
REV.
NO.
SPCR
NO.
GET GO FUEL STATION #
FC-
MISC. DETAILS
AETOS CONSTRUCTION CO.
I-90 & SR 430
ERIE, PA 16510 (ERIE)
3090
12/18/14
DWG
103
51057 P051057B
1/8"=1'-0"
DWG
A
01-13-15