GENERAL NOTES E... · plan this sheet. 5.existing panel ecl1 is located in emer. power room 128a,...

2
G G L1-37 (E) LD1-1 (E) J 1 4 2 GFI 1 J J 3 42 C GFI 40 2 C GFI J 3 GFI J 1 2 4 11 GFI GFI C C GFI C GFI J 5 J LD1-31 4 4 38 ELL1-38,40,42 4 J J J J LD1-10,12,14 11 11 LD1-19 LD1-40 6 ECL1-33 12 ECL1-23 LD1-33 C ECL1-25 J 5 LD1-3 ECL1-27 LD1-5 LD1-35 LD1-6 12 ECL1-19 12 L2-16 ECL1-11 J 1 4 78" AFF ECL1-5 ECL1-17 78" AFF ECL1-15 L2-14 ECL1-9 J 6 ECL1-3 C GFI ELL1-28 ECL1-21 ECL1-7 C LD1-15 2 2 LD1-29 5 J 5 J LD1-27 LD1-25 5 LD1-11 LD1-9 LD1-7 12 12 12 32 30 J ELL1-30,32 J 9 J 9 J 9 11 C GFI C GFI ECL1-31 J 11 7 8 ECL1-39 J 4 2 +78" 1 L1-28 L1-28 MATCHLINE SEE 3/E4.01 J J ECL1-10,12 5 5 32 J 9 ECL1-14 J 11 30 10 12 ECL1-16 10 12 14 J 7 EDL-17 6 6 6 6 6 6 6 1 1 1 1 1 1 1 L2-31 10 1. REFER TO MECHANICAL AND PLUMBING DRAWINGS FOR EQUIPMENT LOCATION AND REQUIREMENTS. 2. ALL RECEPTACLES AND OUTLETS LOCATED ON FURNITURE SHALL BE COORDINATED WITH ARCHITECTURAL DRAWINGS PRIOR TO ROUGH-IN. 3. VERIFY EXACT LOCATIONS OF ALL EQUIPMENT PER ARCHITECTURAL DRAWINGS. 4. EXISTING PANEL L2 IS LOCATED IN SWITCHGEAR ROOM 128, REFER TO KEY PLAN THIS SHEET. 5. EXISTING PANEL ECL1 IS LOCATED IN EMER. POWER ROOM 128A, REFER TO KEY PLAN THIS SHEET. 6. EXISTING PANEL LD1 IS LOCATED IN ELECTRICAL ROOM 115, REFER TO KEY PLAN THIS SHEET. 7. ALL X-RAY EQUIPMENT EXCEPT REMOTE EXPOSURE BUTTONS SHALL BE SUPPLIED AND INSTALLED BY HSD, FINAL CONNECTIONS SHALL BE BY HSD. 8. ELECTRICAL CONTRACTOR SHALL VERIFY SUPPLIER OF X-RAY REMOTE EXPOSURE BUTTON AND ASSOCIATED WIRING WITH HSD EQUIPMENT SPECIALIST. 9. CONTRACTOR TO PROVIDE ALL NECESSARY EQUIPMENT (NEW PATCH PANELS, WIRE MANAGEMENT, JACKS, FACEPLATES AND CABLE SUPPORTS) AS REQUIRED FOR ALL NEW NETWORK CABLES REFER TO THE OIT CABLING SPEC LOCATED HERE: (HTTP://OIT.UNLV.EDU/FORMS/UNLV-WIRING-SPECIFICATIONS) FOR ADDITIONAL INFORMATION. 10. ALL CONDUITS SHOWN FOR DATA CABLING SHALL BE 1" MINIMUM. 11. PULL STRING TO BE INSTALLED IN EMPTY CONDUIT RUNS SHALL HAVE 200# PULL STRENGTH. 1. JUNCTION BOX LOCATED IN CEILING SPACE, ROUTE 3/4" CONDUIT VIA WALL SPACE DOWN TO SAW CUT AT FLOOR FOR DENTAL CHAIR UTILITY CENTER POWER CIRCUIT. 2. DOUBLE-DUPLEX RECEPTACLE MOUNTED AT FINISHED FLOOR, FOR EXACT LOCATION REFER TO ARCHITECTURAL FURNITURE PLAN, SEE RECEPTACLE INSTALLATION DETAIL ON SHEET E4.01. 3. INSTALL 4" SQUARE JUNCTION BOX AT 48" AFF WITH 1" CONDUIT STUBBED TO CEILING SPACE AT "SECURE" SIDE OF WALL FOR CARD READER. SEE DETAIL 6 ON SHEET E4.01. 4. 3/4"C., 2 #12 & 1 #12 GND RUN IN FLOOR FOR POWER TO DENTAL CHAIR, SAW CUT TO BE DETERMINED IN FIELD (SEE KEY NOTE 2 ABOVE). 5. INSTALL NEW X-RAY HEAD, ARM, WALL BRACKET. CONTRACTOR TO CONNECT EXISTING CIRCUIT SHOWN. SEE GENERAL NOTE 7 ABOVE. 6. INSTALL (2) CAT. 6 CABLES BACK TO IDF ROOM 130 (SEE KEY PLAN FOR LOCATION) AND PROVIDE ALL FINAL CONNECTIONS AND TERMINATIONS, REFER TO GENERAL NOTE NO. 9 & 10 ABOVE. 7. JUNCTION BOX IN CEILING SPACE FOR CEILING MOUNT INTRAORAL X-RAY HEAD, ARM AND BRACKET (ALL X-RAY EQUIPMENT PROVIDED AND INSTALLED BY HSD), COORDINATE EXACT J-BOX LOCATION WITH EQUIPMENT MANUFACTURER DETAIL. 8. DUPLEX RECEPTACLE IN CEILING SPACE FOR CEILING MOUNT MONITOR, COORDINATE EXACT LOCATION WITH HSD. 9. ELECTRICAL CONTRACTOR TO PROVIDE 20A, 120V CIRCUIT FROM CENTER CABINET RECEPTACLE TO CABINET MOUNTED DENTAL LIGHT (LIGHT PROVIDED AND INSTALLED BY HSD). 10. RELOCATED ULTRA-SONIC CLEANER AND ASSOCIATED DISCONNECT, RECONNECT TO EXISTING CIRCUIT, REFER TO SHEET E0.22. 11. JUNCTION BOX IN CEILING SPACE FOR CEILING MOUNT MICROSCOPE, COORDINATE EXACT LOCATION WITH HSD. 12. FLOOR MOUNTED GFI RECEPTACLE FOR DOCTOR UTILITY CENTER, COORDINATE EXACT INSTALLATION WITH HSD. tjk consulting engineers, inc. TJK # 17042 GENERAL NOTES: KEY NOTES: # SCALE: POWER AND DATA PLAN 1 1/4" = 1'-0" SCALE: KEY PLAN NTS IDF ROOM 130 LOCATION PROJECT AREA PROJECT AREA EMER. POWER RM. 128A SWGR. RM. 128 ELEC. RM. 115 1 ADDENDUM #1 10.12.17 30 32 TYP 13. FLOOR BOX SHALL BE EQUAL TO LEGRAND RFB4. 13 13 1 1 1 1 1 1

Transcript of GENERAL NOTES E... · plan this sheet. 5.existing panel ecl1 is located in emer. power room 128a,...

Page 1: GENERAL NOTES E... · plan this sheet. 5.existing panel ecl1 is located in emer. power room 128a, refer to key plan this sheet. 6.existing panel ld1 is located in electrical room

G

G

L1-37 (E)

LD1-1 (E)

J

1

4

2

GFI

1

J

J

3

42

C

GFI

40

2

C

GFI

J

3

GFI

J

1

2

4

11

GFI

GFI

C

C

GFI

C

GFI

J

5

J

LD1-31

4

4

38

ELL1-38,40,42

4

J

J

J

J

LD1-10,12,14

11

11

LD1-19

LD1-40

6

ECL1-33

12

ECL1-23

LD1-33

C

ECL1-25

J5

LD1-3

ECL1-27

LD1-5

LD1-35

LD1-6

12

ECL1-19

12

L2-16

ECL1-11

J

1

4

78"

AFF

ECL1-5

ECL1-17

78" AFFECL1-15

L2-14

ECL1-9

J6

ECL1-3

C

GFI

ELL1-28

ECL1-21

ECL1-7

C

LD1-15

2

2

LD1-29

5

J

5

J

LD1-27

LD1-25

5

LD1-11

LD1-9

LD1-7

12

12

12

32

30

J

ELL1-30,32

J

9

J

9

J

9

11

C GFI

C

GFI

ECL1-31

J

11

7

8

ECL1-39

J

4

2

+78"

1

L1-28

L1-28

MATCHLINE SEE 3/E4.01

J

J

ECL1-10,12

5

5

32

J

9

ECL1-14

J

11

30

10

12

ECL1-16

10

12

14

J

7

EDL-17

6

6

6

6

6

6

6

1

1

1

1

1

1

1

L2-31

10

1. REFER TO MECHANICAL AND PLUMBING DRAWINGS FOR EQUIPMENT

LOCATION AND REQUIREMENTS.

2. ALL RECEPTACLES AND OUTLETS LOCATED ON FURNITURE SHALL BE

COORDINATED WITH ARCHITECTURAL DRAWINGS PRIOR TO ROUGH-IN.

3. VERIFY EXACT LOCATIONS OF ALL EQUIPMENT PER ARCHITECTURAL

DRAWINGS.

4. EXISTING PANEL L2 IS LOCATED IN SWITCHGEAR ROOM 128, REFER TO KEY

PLAN THIS SHEET.

5. EXISTING PANEL ECL1 IS LOCATED IN EMER. POWER ROOM 128A, REFER

TO KEY PLAN THIS SHEET.

6. EXISTING PANEL LD1 IS LOCATED IN ELECTRICAL ROOM 115, REFER TO KEY

PLAN THIS SHEET.

7. ALL X-RAY EQUIPMENT EXCEPT REMOTE EXPOSURE BUTTONS SHALL BE

SUPPLIED AND INSTALLED BY HSD, FINAL CONNECTIONS SHALL BE BY HSD.

8. ELECTRICAL CONTRACTOR SHALL VERIFY SUPPLIER OF X-RAY REMOTE

EXPOSURE BUTTON AND ASSOCIATED WIRING WITH HSD EQUIPMENT

SPECIALIST.

9. CONTRACTOR TO PROVIDE ALL NECESSARY EQUIPMENT (NEW PATCH

PANELS, WIRE MANAGEMENT, JACKS, FACEPLATES AND CABLE SUPPORTS)

AS REQUIRED FOR ALL NEW NETWORK CABLES REFER TO THE OIT

CABLING SPEC LOCATED HERE:

(HTTP://OIT.UNLV.EDU/FORMS/UNLV-WIRING-SPECIFICATIONS) FOR

ADDITIONAL INFORMATION.

10. ALL CONDUITS SHOWN FOR DATA CABLING SHALL BE 1" MINIMUM.

11. PULL STRING TO BE INSTALLED IN EMPTY CONDUIT RUNS SHALL HAVE 200#

PULL STRENGTH.

1. JUNCTION BOX LOCATED IN CEILING SPACE, ROUTE 3/4" CONDUIT VIA WALL

SPACE DOWN TO SAW CUT AT FLOOR FOR DENTAL CHAIR UTILITY CENTER

POWER CIRCUIT.

2. DOUBLE-DUPLEX RECEPTACLE MOUNTED AT FINISHED FLOOR, FOR EXACT

LOCATION REFER TO ARCHITECTURAL FURNITURE PLAN, SEE RECEPTACLE

INSTALLATION DETAIL ON SHEET E4.01.

3. INSTALL 4" SQUARE JUNCTION BOX AT 48" AFF WITH 1" CONDUIT STUBBED

TO CEILING SPACE AT "SECURE" SIDE OF WALL FOR CARD READER. SEE

DETAIL 6 ON SHEET E4.01.

4. 3/4"C., 2 #12 & 1 #12 GND RUN IN FLOOR FOR POWER TO DENTAL CHAIR,

SAW CUT TO BE DETERMINED IN FIELD (SEE KEY NOTE 2 ABOVE).

5. INSTALL NEW X-RAY HEAD, ARM, WALL BRACKET. CONTRACTOR TO

CONNECT EXISTING CIRCUIT SHOWN. SEE GENERAL NOTE 7 ABOVE.

6. INSTALL (2) CAT. 6 CABLES BACK TO IDF ROOM 130 (SEE KEY PLAN FOR

LOCATION) AND PROVIDE ALL FINAL CONNECTIONS AND TERMINATIONS,

REFER TO GENERAL NOTE NO. 9 & 10 ABOVE.

7. JUNCTION BOX IN CEILING SPACE FOR CEILING MOUNT INTRAORAL X-RAY

HEAD, ARM AND BRACKET (ALL X-RAY EQUIPMENT PROVIDED AND

INSTALLED BY HSD), COORDINATE EXACT J-BOX LOCATION WITH

EQUIPMENT MANUFACTURER DETAIL.

8. DUPLEX RECEPTACLE IN CEILING SPACE FOR CEILING MOUNT MONITOR,

COORDINATE EXACT LOCATION WITH HSD.

9. ELECTRICAL CONTRACTOR TO PROVIDE 20A, 120V CIRCUIT FROM CENTER

CABINET RECEPTACLE TO CABINET MOUNTED DENTAL LIGHT (LIGHT

PROVIDED AND INSTALLED BY HSD).

10. RELOCATED ULTRA-SONIC CLEANER AND ASSOCIATED DISCONNECT,

RECONNECT TO EXISTING CIRCUIT, REFER TO SHEET E0.22.

11. JUNCTION BOX IN CEILING SPACE FOR CEILING MOUNT MICROSCOPE,

COORDINATE EXACT LOCATION WITH HSD.

12. FLOOR MOUNTED GFI RECEPTACLE FOR DOCTOR UTILITY CENTER,

COORDINATE EXACT INSTALLATION WITH HSD.

tjk consulting engineers, inc.

TJK # 17042

GENERAL NOTES:

KEY NOTES: #

SCALE:

POWER AND DATA PLAN

1

1/4" = 1'-0"

SCALE:

KEY PLAN

NTS

IDF ROOM 130 LOCATION

PROJECT AREAPROJECT AREA

EMER. POWER RM. 128A

SWGR. RM. 128

ELEC. RM. 115

1

AD

DE

ND

UM

#1

10.

12.1

7

30

32

TYP

13. FLOOR BOX SHALL BE EQUAL TO LEGRAND RFB4.

1213

1213

1

1

1

1

1

1

Page 2: GENERAL NOTES E... · plan this sheet. 5.existing panel ecl1 is located in emer. power room 128a, refer to key plan this sheet. 6.existing panel ld1 is located in electrical room

G

G

1"C

9A

9A

9B

9B

9B

9B

9B

9B

9B

9B

9A

43

39

9

9A

43

43

3A

3A

3A

43

1"C

9A

9A

9A

39

9B

39

9A

9B

43

9

39B

39B

39B

3A3A

39

3A

3A

3A

3A 3A

1"C

1"C

3A

4

4

9

3A

9

4

4

4

4

1"C

1"C

1"C

4

1"C

4

4

4

4

1"C

4

1"C

9

9B

9B

9A

9A

4

4

4

4

4

1"C

9

4

4

1"C

1"C

1"C

1"C

1. REFER TO MECHANICAL AND PLUMBING DRAWINGS FOR EQUIPMENT

LOCATION AND REQUIREMENTS.

2. ALL RECEPTACLES AND OUTLETS LOCATED ON FURNITURE SHALL BE

COORDINATED WITH ARCHITECTURAL DRAWINGS PRIOR TO ROUGH-IN.

3. VERIFY EXACT LOCATIONS OF ALL EQUIPMENT PER ARCHITECTURAL

DRAWINGS.

4. EXISTING PANEL L2 IS LOCATED IN SWITCHGEAR ROOM 128, REFER TO KEY

PLAN THIS SHEET.

5. EXISTING PANEL ECL1 IS LOCATED IN EMER. POWER ROOM 128A, REFER

TO KEY PLAN THIS SHEET.

6. EXISTING PANEL LD1 IS LOCATED IN ELECTRICAL ROOM 115, REFER TO KEY

PLAN THIS SHEET.

7. ALL X-RAY EQUIPMENT EXCEPT REMOTE EXPOSURE BUTTONS SHALL BE

SUPPLIED AND INSTALLED BY HSD, FINAL CONNECTIONS SHALL BE BY HSD.

8. ELECTRICAL CONTRACTOR SHALL VERIFY SUPPLIER OF X-RAY REMOTE

EXPOSURE BUTTON AND ASSOCIATED WIRING WITH HSD EQUIPMENT

SPECIALIST.

9. CONTRACTOR TO PROVIDE ALL NECESSARY EQUIPMENT (NEW PATCH

PANELS, WIRE MANAGEMENT, JACKS, FACEPLATES AND CABLE SUPPORTS)

AS REQUIRED FOR ALL NEW NETWORK CABLES REFER TO THE OIT

CABLING SPEC LOCATED HERE:

(HTTP://OIT.UNLV.EDU/FORMS/UNLV-WIRING-SPECIFICATIONS) FOR

ADDITIONAL INFORMATION.

10. ALL CONDUITS SHOWN FOR DATA CABLING SHALL BE 1" MINIMUM.

11. PULL STRING TO BE INSTALLED IN EMPTY CONDUIT RUNS SHALL HAVE 200#

PULL STRENGTH.

F: 702.871.8353www.tjkengineers.com

P: 702.871.3621Las Vegas, NV 89148

8728 Spanish Ridge Avenue

tjk consulting engineers, inc.

Suite 100

TJK # 17042

E

N

L

A

O

N

ROGELIO

ESPARZA

E

G

IN

-

RE

N

D

A

VE

O

E

T

A

F

A

T

S

EXP. 12-31-18

P

R

S

I

S

F

O

E

2

N

o. 7

3

5

6

ELECTRICAL

September 8, 2017

1700

W. C

harle

ston

Blvd

.La

s Veg

as, N

evad

a, 8

9102

DRAWING NO.

TITLE

UNLV

SLD

S Fa

culty

Prac

tice

Reno

vatio

ns

116.071 UNLV SLDS FacultyPractice Renovations

1200

Sou

th 4

th S

treet

Suite

206

Las V

egas

, Nev

ada

8910

4P

702.

839.

1200

F 70

2.83

9.12

13

copy

right

201

7 ©

by

aptu

s

STAT

E FIR

E M

ARSH

ALL/

STAT

E PU

BLIC

WO

RKS

DIV

ISIO

N BI

D S

ET9.

8.17

GENERAL NOTES:

CONDUITCONTROL PLAN

E2.02SCALE:

CONDUIT CONTROL PLAN

1

1/4" = 1'-0"

A

SCALE:

KEY PLAN

NTS

IDF ROOM 130 LOCATION

PROJECT AREAPROJECT AREA

EMER. POWER RM. 128A

SWGR. RM. 128

ELEC. RM. 115

4

2"

1

AD

DE

ND

UM

#1

10.

12.1

7

1

1