General Catalog 2015 rev0 - E Instruments 2020 EIG · Bulletin GEN GAS - ed. 08-201 1 Combustion...
Transcript of General Catalog 2015 rev0 - E Instruments 2020 EIG · Bulletin GEN GAS - ed. 08-201 1 Combustion...
Bulle
tin G
EN
- e
d. 06-2
015
Global Smart Measurement Solutions
General Catalog 2015
www.eigroup.biz
E instruments
Infrared Thermometers Calibrators Flue Gas Analysers
The «f
lying e
» :
always
one step a
head !
Bulle
tin G
EN
IR
-
ed. 08-2
011
Infrared Thermometers and Thermal Image Camera process & portable
IRtech Infrared Thermometers
www.eigroup.biz Features are related to the best of each model equipped with full configuration.
Temperature range up to 3000°C
Optical resolution up to 300:1
Spectral response :8-14µm ( low temperature )1µm, 1.6µm ( high temperature )3.9, 2.3µm ( medium temperature )4.2µm, 4.6µm ( gas )5.1µm ( glass surface ) 7.9µm ( plastic film )Dual color
Dual laser pointer
Compact head 12x28mm
work up to 250°C ambient temperature without cooling
1mS response time
Signal Output :mV, V, 4-20mAUSB, RS485, RS232EthernetCAN-BusProfibus DPRelay
IRtechInfrared Technology
Each body, at temperatures above the absolute zero (-273°C or 0K),emits energy as electromagnetic radiation. When temperature rises,the intensity of this infrared energy increases.The temperature of the body surface can therefore be determined by measuring the intensity of this energy in a small spectral band: the infrared region. The instruments used to measure this energy and to calculate the related temperature are called infrared thermometers or non-contact thermometers.Temperature measurements of a liquid or gaseous compound have been successfully made with thermoelectric or expansion thermometers, thanks to the good thermal exchange of the sensor with the fluid. With solid bodies, a good thermal exchange is difficult to be obtained and an additional measuring error should be considered. When the target is moving or is electrically hazardous, a contact temperature measurement can’t be made. Non-contact IR temperature measurement could be the only solution to the above application problems.Typical application of IRtech portable thermometers is to control temperature where an increase of its value means a possible machine wearing, aging, faulting, etc.
E instruments
IRtech Infrared ThermometersInfrared Thermometers and Thermal Image Camera process & portable
Speci
ficatio
ns
may
change w
ithout notic
e
Process Fixed Models
26
IRtechInfrared Technology
Micro Series : IR6 IR10 IR12
TRX Series : IR40- Stainless steel housing M48- Temperature up to 1600°C- Spectral response : 8-14µm, 1.6µm- Optics up to 300:1 with dual laser- Analog output : 2-wire 4-20mA - USB digital output and Alarm
Split Compact Head with remote display Series : IR14
- Compact M12 28mm head with Remote Programmable Display- Up to 250°C ambient temperature without cooling- Temperature up to 1600°C- Spectral response : 8-14µm,1µm,1.6µm 2.3µm,5.1µm and 7.9µm- Optics up to 75:1 - Output : V,4-20mA,Thermocouple - USB RS232 RS485 CANBus Profibus DP Ethernet interface / Dual Alarms board- ATEX kit
Fiber Optic Series : IR60&100- Fiber optic up to 22mt (up to 250°C)- Standard or Remote Programmable Display with laser pointer- Temperature up to 1800°C- Spectral response : 2 color, 1µm, 1.6µm- Optics up to 80:1 with variable focus- Output : V,4-20mA,Thermocouple - USB RS232 RS485 CANBus Profibus DP Ethernet interface / Dual Alarms board
- Compact M12 (IR10-12 28mm IR6 87mm)- Temperature up to 900°C- Optics up to 10:1- IR6 : Volt output IR10-12 : 2-wire 4-20mA- USB output / IR6 : Built-in alarm led
Thermal Image : TImage- Compact 45x45x62mm IP67- Process fixed and portable use- Temperature up to 900°C- Fast 100Hz with USB 2.0 output- Analog/ digital I/O- Interchangeable lens 9°,31°,64°- Standard PC realtime software
MiniRay- Compact : 190 mm - 150 gr- Temperature up to 760°C- Laser pointer with Optics up to 40:1- Thermocouple Tc K input- USB and Software
Pro 880- Temperature up to 900°C- Laser pointer with crosshair- Dual switchable optics ( macro-tele) up to 75:1 or 1mm- Thermocouple Tc K input- 100 Memories, USB and Software
Pro 1100 / 1330 / 2200- Temperature up to 1800°C- Dual laser pointer- Telescope visual sighting- Optics up to 300:1- 2000 measures datalogger - USB and Software
Portable Models
IR Software- IR softwares for process fixed, for portable units and for thermal image camera.- Real time Graphic display- Datalogging- Advanced signal processing capability- Reporting
Timage Pro- Temperature up to 1500°C- Resolution 160x120 or 384x288- TFT Lcd display 3,6"- Visible Camera 2MP with Fusion- SD Memory card & video recording- USB port and Windows Software
Split with Laser Series : IR20- Advanced dual laser M48 head with Remote Programmable Display- Temperature up to 1800°C- Spectral response : 8-14µm, 1µm, 1.6µm 2.3µm, 3.9µm, 4.2µm, 4.6µm, 5.1µm and 7.9µm- Optics up to 300:1 - Output : V,4-20mA,Thermocouple - USB RS232 RS485 CANBus Profibus DP Ethernet interface / Dual Alarms board
High performance Series : M
- Standard and Fiber optic - Through lens sighting- Temperature up to 4000°C- Spectral response : 2 color, 1-1.6-2.1µm- Optics with variable focus
Bulle
tin G
EN
GA
S -
ed. 08-2
011
Combustion Flue Gas Analysers for Industrial applications
ECOline 1400 4000 8800 OLS100..400
www.eigroup.biz Features are related to all models equipped with full configuration. On next pages you can find specific details.
Up to 9 sensors :O CO CO2 2
NO NO NO2 x
SO H S C H2 2 x y
electrochemical or NDIR
Temperature
Pressure / Draft / Flow
Built-in Peltier Gas dryer
Heated tube & probe
Battery powered
Datalogger
Analog outputs
Built-in Printer
Graphic LCD display
ECOline
The “Clean Air Act”,promulgated in U.S.A. in 1970, was certainly the first law that regulates air emissions fromarea, stationary and mobile source. EPA (Environmental Protection Agency) and other country or state Regulatory Agencies verify affordable and reasonable methods of achieving environmental compliance to verify stated emissions limits. A number of official “Protocols” have been promulgated to verify industrial emissions using portable analyzers to ensure air quality compliance. These “Protocols” are the guidelines that prescribe the technical performances of the electrochemical sensor based analyzers to be used, as well as calibration and testing procedures which should be followed to assure valid emission data.
Combustion Gas Analysis
E instruments
ECOline Sensonic 1400 4000 8800 IRCombustion Flue Gas Analysers for Industrial applications
Speci
ficatio
ns
may
change w
ithout notic
e
Portable Models
ECOline Mk3
26
ECOline 1400
Specifications as Mk3:- Up to 4 sensors O CO NO NO SO2 x 2 2
- Smoke test with internal pump- 64 complete analysis memories- Low draft 0,1 Pa probe
ECOline 4000Specifications as 1400 plus :- Built-in impact printer- Up to 4 sensors O CO NO NO SO H S2 x 2 2 2
CO C H NDIR 2, x y
- 3 analogs inputs ( mA/V - Tc - Therm. )- 1000 complete analysis memories
ECOline 8800
Specifications as 4000 plus :- Up to 8 sensors O CO NO NO SO H S2 x 2 2 2
CO C H NDIR 2, x y
- Built-in cooler - dryer- Heated tube and Probe- 3 analogs inputs ( mA/V - Tc - Therm. )- 2 optional analog outputs
- Graphic display- Up to 3 sensors O CO NO2 x
- Flue and Air Temperature - Pressure, Draft and Flow- CO ambient 0,1ppm- External compact printer- Datalogger, RS232/USB, Windows software- Efficiency/Excess of Air/CO calculation2
- Average of measured analysis- EN50379 compliant- 64 complete analysis memories- Internal firmware upgradeable- RH relative humidity probe- Programmable fuels ( up to 10 )- Magnetic plate
ECOline IR
Specifications as 4000 plus :- 7 sensor NDIR CO NO NO SO N Ox 2 2 2
CO C H 2, x y
- Large LCD 320x240 graphic display - Advanced dual line filtering - 256K MMC memory for datalogging- 8 optional analogs inputs ( Tc - Therm. )- 8 optional analog outputs
ECOline OLS100,200,300,400
- On line combustion analyser- 1,2,3 or 4 gas models- Sensors O partial pressure2
CO NO NO SO H S electrochem. 2 2 2
CO.CO N O CH NDIR 2, 2 , 4
- Draft & Temperature- Peltier dryer, condensation pump- Datalogger with RS232/RS485- 4 analog output (V/mA)
ECOline AB Landfill & Biogas- Portable unit- Measurement of CO2 60%, CH4 70%, H2S 700ppm, CO 2%,NH3 1000ppm O2 25%- Built-in pump and memory
Software- Windows software- Datalogging- Graphics trend- Save on PC- Connect via RS232/USB to analysers
Online Models
T&M Complementary
- Mini LV Vane Anemometer- Mini VT Hot Wire Anemometer - Mini HD Thermo Hygrometer- Mini CT Tachometer- Mini TK Tc K Thermometer 2 channels- Mini MP Pressure meter
ECOlineCombustion Gas Analysis
Gas Detector (safety)- Fixed and Portable- Single and four gases- ATEX- Multichannel control station
Bulle
tin G
EN
CA
L -
ed. 08-2
011
Advanced Process Signal, Temperature and Pressure Calibrators
www.eigroup.biz Features are related to all models equipped with full configuration. On next pages you can find specific details.
Signal Tc, Rtd, mA, mV, V, Hz, Pulse
Temperature dry-block and liquidfrom -50°C up to 1200°C
WS Tc and Pt100 thermomters
Pressure up to 700 Bar (10KPSI) with pressure generator
Hart protocol
ATEX model
Documenting calibrator
High Accuracy
Rechargeable batteries
Graphic LCD display
Calibration can be briefly described as an activity where the instrument being tested is compared to a known reference value. At the simplest level, calibration is a comparison between measurements – one of known magnitude or correctness made or set with one device, and another measurement made in as similar a way as possible with a second device. The device with the known or assigned correctness is called the standard. The second device is the unit under test or test instrument. Calibration is often required with a new instrument or when a specified time period or a specified number of operating hours has elapsed. In addition, calibration is usually carried out when an instrument has been subjected to an unexpected shock or vibration that may have put it out of its specified limits.
E instruments
MAXiCALProcess Multifunction Calibrators
MAXiCAL
MAXiCALAdvanced Process Signal, Temperature and Pressure Calibrators
Speci
ficatio
ns
may
change w
ithout notic
e
Signal process Models
MaxiCAL Tc/ RTD / Loop
26
MaxiCAL TRX Multifunction
- Simultaneous measure/generation - Loop : mA 24VPS, V- Thermocouple, Rtd- Graphic display- Easy setting with in-line keyboard- Step, ramp, logging with SD card- LiION battery
MaxiCAL 310 Documenting Multifunction
- Color High resolution TFT Display- Documenting- Thermocouple and Rtd - Loop, mV, Volt, Frequancy & Pulse- Pressure module up to 700 Bar- Hart option- LiION rechargeable batteries- Digital interface & Software
Manometer Calibrator PPC- High accuracy manometers 0,05%- Pressure up to 1000 Bar
- Loop : In/Out mV,V,mA. 24V PS for loop.- Rtd : In/out RTD and Ohm
Pt10,Pt50,Pt100,Pt200,Pt500,Pt1000- Tc : In/Out TC J,K,T,E,R,S,B,N & mV- Alkaline batteries
MaxiCAL PPC 273 pressure calibration kit - Pressure calibration & Signal, HART accuracy 0,02%- Pressure from mBar to 2500 Bar- Differential, gauge and absolute
Temperature Models TEMP
Documenting Calibrator MF4010Hart Programmer MF4150
- Modular calibrators- Documenting with Graphic display- Rugged with rubber holster- 3 modules capability - Tc, Loop, Rtd, Pressure modules- Hart programmer communicator ATEX- Device profiles upgradeable- Clone/Upload/Download/Off line
Pressure Models PPC
SOLAS Marine Cal Kit- Temperature up to 600°C- Pressure pneumatic & hydraulic- IP67 robust case
MaxiCAL PPC300
- Pressure calibration & Signal 0,025%- Documenting - Pressure from up to 1000 Bar
MAXiCALProcess Multifunction Calibrators
MaxiCAL TEMP Compact&Basic- Compact : LOT -10 a 110°C. MT 35 a 300°C - Basic : LOT -24°C+125°C, MTL Amb - +375°Cand MT Amb to +650°C
MaxiCAL TEMP
- LOT : -45 to 150°C Dry block- LOT Fluid : -30 to 125°C fluid bath- MT Fluid : Ambient to 200°C fluid bath- MT : Ambient to 600°C Dry block- HT : 200 to 1150°C Dry block- Dual channel input Tc / Rtd - Switch test
Working Standard Thermometers- WS Pt100 working standard thermometer- WS Tc S, Tc K standard thermometer
MaxiCAL TEMP PRO
- LOT : -55 to 140°C. Liquid+Dryblock- MT : Amb to 650°C Dryblock- HT : 150 to 1200°C Dryblock- Black Body Insert
Service & CalibrationTraining CourseTechnical consulting
Bulle
tin G
EN
- e
d. 08-2
011
www.eigroup.biz
E instruments group
Infrared Thermometers Calibrators Flue Gas Analysers
distributed by :
E Instruments Group Srlmail : [email protected]
E instruments born on 25 years experience. The know-how is technical ( more than twenty products wasdeveloped in the past ) to commercial competences on the global market.The support start from consultancy on how to solve the application selecting the right product, passing to the supply of the products, granting after sales support.The internal laboratory is able to provide warranty, service and calibration support. Our line of products use cutting edge technology at competitive price. We offer you smart measurement solutions, just what you need to solve your application at the best. Italian know-howwith international recognition. We are proud of it ! Guido Moro - CEO