GENERAL ACOUSTICS GMBH©
Autonomous Remote Sensing of Water Level and Waves
The LOG_aLevel® - Systems
Distributor-Seminar
Oceanology International 2008, London
GENERAL ACOUSTICS GMBH©
LOG_aLevel® - The Robust, Economic and Accurate Water Level Gauge and Wave Measurement System via Ultrasound
Technology
What kind of Systems does the Market need?
Robust, Low Maintenance, Economic and Accurate Measurement Systems Redundancy of Sensing Technology Wave Measurements
Universal Selling Properties and Advantages of the LOG_aLevel®:
Robust, Maintenance Free, Cost Effective, Low Installation Effort, Portable Calibration Free due to Outstanding Sound Velocity Compensation Due to low Installation Effort and cost effective systems new measuring
locations / aplications are possible Accurate Level Measurement also at Wavy Surface Accurate and High Resolution Wave Measurements Solely Approved Remote Sensing Level Gage in Germany as an Alternate
or Complement to Radar
GENERAL ACOUSTICS GMBH©
LOG_aLevel® - Applications, Clients and Examples
Applications:• Water level monitoring • Wave measurement and analysis, determination of Wave Parameters• Event Alerting System for a fast detection of Storm Tides, Floods or
Tsunamis• Water reservoir management to measure highly accurate the water
level• Mobile Operating Level Gauge• Complete hydrological and metrological monitoring station• Monitoring Discharger of e.g. Power Stations
Clients: • Harbour-, River- and Coastal Authorities, EPAs• Research Institutes and Universities• Water Resources Authorities• Energy Producers• Dredging and Surveying Industry• Oil and Gas Industry• Commercial shipping• Tourist Industry
GENERAL ACOUSTICS GMBH©
Nienstedten
Strandkai
Billwerder Sperrwerk
Harburger Schleuse
Network consists of:
• 4 LOG_aLevel Stations
• Integration of wind sensor
• Autonomous power supply (wind and solar)
• Remote data transfer via GPRS
Storm Tide Network at Port of Hamburg
GENERAL ACOUSTICS GMBH©
The Storm-Tide-Network in the Port
of Hamburg
(Location: Nienstedten)
Ultrasound-Sensor Controller
Antenna
GENERAL ACOUSTICS GMBH©
BfG (Federal Institute of Hydrology) Test in Gnevsdorf, River Havel(Germany)
GENERAL ACOUSTICS GMBH©
The Mobile LOG_aLevel®
• Light weight
• No Calibration
• Easy to deploy and set-up
• Robust and reliable
GENERAL ACOUSTICS GMBH©
Selected LOG_aLevel® Customer Applications• Reliable water level measurement for keel- and/or bridge clearance
• Hydrographical Survey support with precise water level, data transmission via radio to the survey vessel
• Dredging operation support with precise water level, data transmission via radio to the survey vessel
• Reliable Stormtide- and flood warning via SMS and level data access via VPN
• Reliable and redundant water level measurement for sluice control
• Long term water level monitoring on river for tourist management
• Integrated water/wave level- and meteorological station
• Monitoring of torrents (snow melting/heavy rain fall)
• Increasing the density of water level station in a local inland water level network
• Measurement of waves for evaluation of wave energy and estimation of loads for quay design
• Wave measurement for a local wave model - Input and Validation
• Wave and tidal monitoring for coastal protection
• Measuring of ship induced waves for estimation of loads on shores
• Reconstrucion of damages and causer identification based on level and wave measurement
GENERAL ACOUSTICS GMBH©
12 V DCPower Supply Module
Telemetry Modules:- Radio/GSM/GPRS/- LAN, 0-20 mA, etc.
PCMCIA Data Logger
Standard EquipmentOptional Equipment
External Sensors - Wind, Pressure, - Radar, Weather, etc.
- AC Power Supply- Wind Generator- Solar Panel- Buffer-Battery
Ultrasound-Sensor(s)
Controller Module
RS 232/485 Output
GPS synchronised RTC(integrated in Controller)
Display Module
Modular design of the LOG_aLevel
Sound velocity probe
Stainless steel housing
LOG_aLevel Software
GENERAL ACOUSTICS GMBH©
LOG_aLevel® in big housing
Modular Construction
• Controller
• Data Logger
• Power Supply 12 V
• Power Supply 230 V
• GSM/GPRS
• 80 Ah Buffer Battery
GENERAL ACOUSTICS GMBH©
LOG_aLevel® - The Ultrasound-SensorThe Innovation:Fast, precise and remote detection of
waves and water levels
Sensor characteristics•Narrow sound beam ensures
small footprint on water surface
•Free of disturbing minor sound beams
•Extraordinary high transmitting power and receiving sensitivity
•Technical resolution: 0.360 mm
•Accuracy in field operation: 1 cm
•Sampling rate up to 5 Hz
•Only 250 g weight
•6 m, 8 m and 10 m range available
•Operating temperature: of -20 ° C to +70 ° C
Easy installation at any place
•jetties, wharfs, sluices, embankment•beacons, dolphins, poles, bridges•buildings, platforms, etc.
GENERAL ACOUSTICS GMBH©
LOG_aLevel® compared to common systems Common
Ultra-sound Sensors or Radar Sensor
GENERAL ACOUSTICS GMBH©
LOG_aLevel® Controller and Power SupplyController module for signal
processing and sensor control/data acquisition (incl. Timer), Digital data transfer via interface RS 232 or RS 485and Data Logger output
Power ON/OFF switchPower test buttonInput: 12 VOutput: Controller Power 12 V for e.g. Radio 5 V for Data Logger 24 V for e.g. Wind Gauge
GENERAL ACOUSTICS GMBH©
Sound Velocity measurement due to the possible change of temperature, air pressure and humidity
By using the directly measured ultrasound velocity in air and the measured travel time it is possible to accurately compute the water level due to the continuously calibration.
LOG_aLevel® Reference-Sensor
GENERAL ACOUSTICS GMBH©
LOG_aLevel®, additional Power Supply
Standard Lead-Gel-Buffer Battery 80 Ah will support the LOG_aLevel system with a current consumption of 500 mA for more than 6 days with power
Standard Wind Generator
200 Watts at 20 Knots
Standard Solar Panel
85 Wp = 340Wh/day
Input: 100 V - 240 VAC /50/60 HzOutput: 12 VDC; 3,5 A
GENERAL ACOUSTICS GMBH©
LOG_aLevel® Data Logger Module
IMPORTANT:The file with the level data is ALWAYS called "PEGEL.LOG" and MUST ALWAYS be in the directory of the data medium. It must be available on the data medium before the measuring campaign. The data logger is not able to create this file by itself.
The Compact Flash-Card may not be pulled out during operation. In such case, the level LOG_aLevel station must be turned off and then set again in operation.
- Standard card size 1 GB CF Industrial Grade, up to 2 GB cards supplied- In continuous mode at 5 Hz sample rate a 1 GB card has space for 6 months of data
GENERAL ACOUSTICS GMBH©
LOG_aLevel® GSM/GPRS and Radio Module
GSM/GPRS transmission to dynamic DNS or fixed IP-Address via the internet
• Licence or Licence-Free Versions available
• Up to 50 Km range depending on Antenna, Power and Environment
GENERAL ACOUSTICS GMBH©
LOG_aLevel® additional Modules and Sensors
RS232/485 converterto LAN
Analogue output Module
Display Module to show the direct water level in the office, on a dredger or survey ship
Multi-parameter weather station with the 6 most essential weather data
Anemometer to measure wind speed and direction
and the virtual temperature
GENERAL ACOUSTICS GMBH©
The LOG_aLevel® - Software for data logging and control
Real-Time visualizing of Water Level and the Wave Parameter (H1/3)
GENERAL ACOUSTICS GMBH©
How to set the LOG_aLevel® Adjustment Level
1. Execute a LOG_aLevel measurment with Adjustment level=0
2. The result is the distance between sensor and water surface in a negative value
3. Subtract from the actual local datum this value and use the result as Adjustment level for this station. So you get the exact tide level measured with the LOG_aLevel
LOG_aLevel
Example:
Zero measurment= - 3 m (adj. Level=0)
Actual local datum: 4.5 m
4.5 m – (-3 m)= 7.5 m
With 7.5 m adjustment level, the LOG_aLevel will show the result 4.5 m actual tide level
GENERAL ACOUSTICS GMBH©
LOG_aLevel® Questions and Answers
1. When starting LOG_aLevel® Software, you receive “System Error, Code: 2”. Reason: You have chosen the wrong COM Port in the LOG_alevel.ini. Solution: Find out the right COM Port in your Windows Device Manager and change then in the LOG_aLevel.ini in row COMParams= port=X (1 is standard)
2. LOG_aLevel® does not start to measureReason: Battery has a too low voltageSolution: Charge battery (without load about 13.5 V)
3. LOG_aLevel® does not start to measure and battery has been already chargedCheck if sensor is “pinging” by listening at the sensor. If no, check cables and connectors. Press button at power supply to check voltage with blue light. Check fuse. If sensor pings, check if RS232 cable is the original crossed cable (pin 2 and 3 crossed).
4. LOG_aLevel® just starts for some seconds to measure, indicated by blue LED in SWReason: Controller was set by the software to “sleep mode” Solution: Connect Laptop to controller, start software and change to continuous mode or periodic mode
5. LOG_aLevel® results only show value of adjustment level valueReason: LOG_aLevel® sensor is not connectedSolution: check cables and connectors
6. LOG_aLevel® results show values too high Reason: reference track is not working or connectedSolution: check in the data LOG-file if value for sound velocity is around c=33000. If c=22900, reference sensor does not work. Check reference sensor, cables and connectors.
GENERAL ACOUSTICS GMBH©
LOG_aLevel® General Advantages
1. Calibration and maintenance free
2. Robust, precise, economical and compact
3. Modular system to fulfil different customer requirements and easy upgrade and
maintenance due to simple exchange of modules
4. Reliable even under extreme conditions: flood, ice, storms, debris, fog, etc.
5. Low installation effort as stationary or mobile version
6. Accurate level measurements even with wavy surface
7. Redundancy or alternative to conventional level measurement techniques
8. Completely autonomous operation possible
9. Worldwide approved, tested and in operation
10. Easy to use Windows-Software for data logging and control
GENERAL ACOUSTICS GMBH©
LOG_aLevel® around the World
LOG_aLevel is used on all continents in more than 28 countries under all possible environmental conditions
GENERAL ACOUSTICS GMBH©
LOG_aLevel® Selected References• Rijkswaterstaat: Ministry of Transport + Watermanagement, (RIZA), The
Netherlands
• Port of Hamburg (Hamburg Port Authority), Germany
• US-Army Corps of Engineers San Francisco District (USACE), USA
• Project: North Sea Monitoring System: Government Schleswig-Holstein, Germany
• Bundesanstalt für Gewässerkunde (BfG), Koblenz (Federal Institute of Hydrology),
Germany
• National Institute of Ocean technology (NIOT), India
• Port of Le Havre (Port Autonome du Havre), France; Port of Seoul, Korea
• MRTS, Varanday-Oil and Gas Terminal, Russia
• Geofísica y Posicionamiento Satelital GPSCA, Maracaibo Lake, Venezuela
• Ecologia, Vouneuil-sur-Vienne, River Vienne, France
• Wasser- und Schifffahrtsamt Brandenburg (Waterways and Shipping Board),
Germany
• Bayer. Landesamt für Wasserwirtschaft (Bavarian Ministry of Environment),
Germany
• Leibniz-Institute of Freshwater Ecology and Inland Fisheries (IGB-Berlin), Germany
• Agency for Water Management, Coast and Nature Protection of Lower Saxony),
NLWKN –
Norderney, Germany and NLWKN – Brake, Germany
• University of Moscow, Russia, University of Tallinn, Estonia
• Flinders Ports, Australia
• Proudman Oceanographic Laboratory, United Kingdom