Gendrive Series 2000 Gx5 - mtu-online-shop.com...Gendrive Series 2000 Gx5 for Power Generation...
Transcript of Gendrive Series 2000 Gx5 - mtu-online-shop.com...Gendrive Series 2000 Gx5 for Power Generation...
Gendrive
Series 2000 Gx5 for Power Generation Standard Backup Applicationswith water-to-air charge air cooling
Power. Passion. Partnership.
Dimensions and Masses
Engine Dimensions(LxWxH)mm(in) Mass,drykg(lbs)
12V 1835x1580x1570(72x62x62) 2570(5665)
16V 2180x1580x1580(86x62x62) 3180(7010)
18V 2350x1580x1600(93x62x63) 3580(7893)
Alldimensionsareapproximate,forcompleteinformationrefertotheinstallationdrawing.
EngineModel
Bore/stroke mm(in) 130/150(5.1/5.9)
Cylinderconfiguration 90°V
Displacement/cylinder l(cuin) 1.99(121)
Displacement,total l(cuin) 12V:23.9(1458),16V:31.8(1944),18V:35.8(2185)
Fuelspecification EN590,GradeNo.1-D/2-D(ASTMD975-00)
Applicationgroup Powerdefinition
StandbyPower(3D) Emergencyservice,fuelstoppower, Loadfactor:≤85%,Operatinghours:max.500h/year,
IFN Overload:Fuelstoppower(IFN)
PowerdefinitionaccordingtoISO3046(ratingsalsocorrespondtoSAEJ1995andSAEJ1349standardconditions).ConsultyourMTUdistributor/dealerfortheratingthatwillapplytoyourspecificapplication.Rated power is without fan drive. The power consumption of any fan drive has to be deducted during designing of a generator set.
2IStandardBackupApplications
193 referencetoemissionlevelinpricelist
Engine Type Rated power kW (bhp) at 1800 rpm (60Hz) Optimization
12V2000G45 780(1046) x x
12V2000G85 890(1194) x x
16V2000G45 1010(1354) x x
16V2000G85 1115(1495) x x
18V2000G85 1310(1757) x x
Fanpowerrequirementnotconsidered
US
EPA
Non
road
Tie
r 2
com
plia
nt (4
0 C
FR 8
9)
US
EPA
Sta
tiona
ry
EMER
G T
ier
2 (4
0 C
FR 6
0)
Standby Power (3D)
Engine Type Rated power kW (bhp) at 1500 rpm (50Hz) Optimization
12V2000G25 635(852) x
12V2000G65 765(1026) x
16V2000G25 890(1194) x
16V2000G65 975(1307) x
18V2000G65 1100(1475) x
FanpowerrequirementnotconsideredFu
el c
onsu
mpt
ion
optim
ized
319
MTU Friedrichshafen GmbH I MTU Asia Pte Ltd I MTU America Inc.Rolls-RoycePowerSystemsCompanies
www.mtu-online.com
Subj
ectt
och
ange
.|3
2391
61|
Edi
tion
01/
16|
EN
C2
016-
03.
StandardEquipment
StartingSystem Electricstarter(24VDC/2-pole)
FuelSystem Electronicallycontrolledhigh-pressureinjectionwithsingleunitinjectionpumps(EUP)
LubeOilSystem Forcedfeedlubricationsystemwithpistoncooling,lubeoilcirculationpumpwithsafetyvalve,lubeoilmulti-stage
filter,lubeoilheatexchanger
CombustionAirSystem Exhaustturbochargers,intercooler
CoolingSystem Coolantcirculationpumpandcoolantthermostatforjacketwaterandchargeaircoolingsystem
EngineMounting Setofenginemountingbracketsatenginefreeanddrivingend
EngineManagement IntegratedelectronicenginecontrolandmonitoringsystemADEC
OptionalEquipment
StartingSystem Redundantstartingsystemelectric/air;electric/electric;air/air
FuelSystem Fuelpre-filter,specialfuelpre-filterwithwaterseparator
LubeOilSystem Handpumpforlubeoilextraction,electricalintervalpre-lubricationpump
CombustionAirSystem Heavydutyairfilters
EngineMounting Resilientenginemounts(rubberelements),rigidenginemounting
Referenceconditions:–Intake-airtemperature:25°C(77°F)–Ambientairpressure:1bar(14.5psi)–Altitudeabovesealevel:100m(328ft)
Subjecttochangewithoutnotice.Customizationpossible.Enginesillustratedinthisdocumentmayfeatureoptionsnotfittedasstandard.