GEH275-2 - ABI HAIDAR Motorsabihaidarmotors.com/wp-content/uploads/2017/02/GEH275.pdf · 3 Phase...

4
Engine Make & Model: Perkins 1306C-E87TAG6 Circuit Breaker Type: 3 Pole MCCB Fuel Tank Capacity: litres (US gal) 350 (92.5) Frequency: 50 Hz 60 Hz Fuel Consumption, Prime: l/hr (US gal/hr) 58.9 (15.6) - Engine Speed: RPM 1500 - Alternator Model: LL5014J Base Frame Type: Heavy Duty Fabricated Steel Fuel Consumption, Standby : l/hr (US gal/hr) 63.3 (16.7) - Output Ratings Generating Set Model Standby* 275.0 kVA 220.0 kW - - Prime* 250.0 kVA 200.0 kW - - 380-415V,50Hz * Refer to ratings definitions on page 4. Ratings at power factor. 0.8 GEH275-2 Technical Data Diesel Generator Set Exclusively from your Caterpillar® dealer

Transcript of GEH275-2 - ABI HAIDAR Motorsabihaidarmotors.com/wp-content/uploads/2017/02/GEH275.pdf · 3 Phase...

Page 1: GEH275-2 - ABI HAIDAR Motorsabihaidarmotors.com/wp-content/uploads/2017/02/GEH275.pdf · 3 Phase Ratings and Performance at 50 Hz, 1500 RPM Voltage Prime Standby Standby Rating These

Engine Make & Model: Perkins 1306C-E87TAG6

Circuit Breaker Type: 3 Pole MCCB

Fuel Tank Capacity: litres (US gal) 350 (92.5)

Frequency: 50 Hz 60 Hz

Fuel Consumption, Prime: l/hr (US gal/hr) 58.9 (15.6) -

Engine Speed: RPM 1500 -

Alternator Model: LL5014J

Base Frame Type: Heavy Duty Fabricated Steel

Fuel Consumption, Standby : l/hr (US gal/hr) 63.3 (16.7) -

Output Ratings

Generating Set Model Standby*

275.0 kVA

220.0 kW

-

-

Prime*

250.0 kVA

200.0 kW

-

-

380-415V,50Hz

* Refer to ratings definitions on page 4. Ratings at power factor.0.8

GEH275-2

Technical Data

Diesel Generator SetExclusively from your Caterpillar® dealer

Page 2: GEH275-2 - ABI HAIDAR Motorsabihaidarmotors.com/wp-content/uploads/2017/02/GEH275.pdf · 3 Phase Ratings and Performance at 50 Hz, 1500 RPM Voltage Prime Standby Standby Rating These

6.2 (25.0)

424.2 (14980)

Air Filter Type:

Combustion Air Flow:

m³/min (cfm) -Standby:

-Prime:

Max. Combustion Air Intake

Restriction: kPa (in H2O)

Paper Element

-16.4 (579)

-16.4 (579)

-

Radiator Cooling Air Flow:

m³/min (cfm)

External Restriction to

Cooling Air Flow: Pa (in H2O) -125 (0.5)

-

Air System 60 Hz50 Hz

Moment of Inertia: kg m² (lb. in²) 1.54 (5266)

Governing Type:

Governing Class:

Compression Ratio:Displacement: l (cu.in)

Engine Electrical System:

-Voltage/Ground:

-Battery Charger Amps:

Weight: kg (lb) - Dry:

- Wet:

Cooling Method: Water

Electronic

ISO 8528 G2

16.9:1

8.7 (530.9)

Bore/Stroke: mm (in) 116.6 (4.6)/135.9 (5.4)

24/Negative

45671 (1479)

698 (1539)

Induction:

Manufacturer: Perkins

Model: 1306C-E87TAG6

No. of Cylinders/Alignment: 6 / In Line

Cycle: 4 Stroke

Turbocharged Air To Air Charge Cooled

-20.8Regenerative Power: kW-Prime: 2099.0 (304.5) -

-2306.0 (334.4)-Standby:BMEP: kPa (psi)

-228.5 (306.0) -Prime:

-Standby:Gross Engine Power: kW (hp)

250.9 (336.0) -

-1500Engine Speed: RPM

Oil Pan l (US gal):

Total Oil Capacity l (US gal):

Oil Filter Type:

Oil Type:

Cooling Method:

Spin-On, Full Flow

26.4 (7.0)22.7 (6.0)

API-CH-4

Water

Prime

50 Hz 31.1 (8.2)60 Hz ----

46.1 (12.2)58.9 (15.6)63.3 (16.7)

(based on diesel fuel with a specific gravity of 0.85 and conforming to BS2869, Class A2)

Recommended Fuel:

Fuel Consumption: l/hr (US gal/hr)Class A2 Diesel

110%Load

75%Load

50%Load

100%Load

Fuel Filter Type: Replaceable Element

Standby

50 Hz 34.3 (9.1)50.2 (13.3)63.3 (16.7)

60 Hz ---

Level: dB

Silencer System: kPa (in Hg)

Pressure Drop Across

Silencer Noise Reduction

Silencer Type:

Pressure: kPa (in. Hg)

Max. Allowable Back

-Prime:

m³/min (cfm) -Standby:

Exhaust Gas Flow:

-Prime:

m³/min (cfm) -Standby:

Exhaust Gas Temperature: °C (°F)

SD100 (0)Silencer Noise Reduction

-8.70 (2.569)

-12

-10.7 (3.2)

-44.5 (1572)

-44.5 (1572)

-528 (982)

-500 (932)

Level 1Cooling System Capacity: l (US gal)

Water Pump Type:

Heat Rejected to Water &

Lube Oil: kW (Btu/min)

-Standby:

-Prime:

-Prime:

kW (Btu/min) -Standby:Heat Radiation to Room:

Radiator Fan Load: kW (hp)

110.0 (6256)

-

-45.3 (12.0)Centrifugal

-

-103.0 (5858)

-44.0 (2502)

-40.0 (2275)

10.3 (13.8)

Cooling system designed to operate in ambient conditions up to 50°C (122°F). Contact your local Olympian dealer for power ratings at specific site conditions.

Cooling System 60 Hz50 Hz

Performance 60 Hz50 Hz

Fuel System

Exhaust System

Lubrication systemPhysical Data

Engine Techncial Data

Consult your Olympian representative for more information

60 Hz50 Hz

Page 3: GEH275-2 - ABI HAIDAR Motorsabihaidarmotors.com/wp-content/uploads/2017/02/GEH275.pdf · 3 Phase Ratings and Performance at 50 Hz, 1500 RPM Voltage Prime Standby Standby Rating These

Data Item50 Hz 60 Hz

Motor Starting Capability* kVA 623 585 536 686 - - - - -

Reactances: Per Unit

Xd

X'd

X''d

2.446 2.633 2.917 2.176 - - - - -

0.112 0.120 0.133 0.100 - - - - -

0.067 0.072 0.080 0.059 - - - - -

Reactances shown are applicable to standby ratings.* Based on 30% voltage dip. Improved motor starting capability is available with optional Permanent Magnet generator or AREP excitation.** With optional Permanent Magnet generator or AREP excitation.

415/240V 400/230V230/115V200/115V

380/220V220/110V

220/127V

Short Circuit Capacity** % 300 300 300 300 300 300 300 300 300

Manufacturer:

Model:

No. of Bearings:

Insulation Class:

Winding Pitch - Code:

Wires:

Ingress Protection Rating:

Excitation System:

AVR Model:

OLYMPIAN

LL5014J

1

H

2/3 - 6

12

IP23

SHUNT

R448

Overspeed: RPM

Voltage Regulation (steady state) (%):

Wave Form NEMA = TIF:

Wave Form IEC = THF:

Total Harmonic Content LL/LN:

Radio Interference:

Radiant Heat: kW (Btu/min)

-50 Hz:

-60 Hz:

Supression is in line with European Standard EN61000-6

-

16.3 (927)

4.0%

2.0%

50

+/- 0.5

2250

Physical Data Operating Data

Alternator Performance Data

Alternator Technical Data

Consult your Olympian representative for more information

Page 4: GEH275-2 - ABI HAIDAR Motorsabihaidarmotors.com/wp-content/uploads/2017/02/GEH275.pdf · 3 Phase Ratings and Performance at 50 Hz, 1500 RPM Voltage Prime Standby Standby Rating These

220.0275.0

220.0275.0

220.0275.0

220.0275.0

220.0275.0

220.0275.0

220.0275.0

kWkVA

200.0

200.0

200.0

200.0250.0

250.0

250.0

250.0

200.0250.0

250.0 200.0

kWkVA

200/115V

220/110V

220/127V

230/115V

380/220V

415/240V

400/230V

200.0250.0

Technical Data Phase Ratings and Performance at 50 Hz, RPM15003

Voltage Prime Standby

Standby RatingThese ratings are applicable for supplying continuous electricalpower (at variable load) in the event of a utility power failure. Nooverload is permitted on these ratings. The alternator on this modelis peak continuous rated (as de�ned in ISO 8528-3).

Prime RatingThese ratings are applicable for supplying continuous electricalpower (at variable load) in lieu of commercially purchased power.There is no limitation to the annual hours of operation and thismodel can supply 10% overload power for 1 hour in 12 hours.

Standard Reference ConditionsNote: Standard reference conditions 27°C (80°F) air Inlet Temp,152.4m (500ft) A.S.L. 60% relative humidity. Fuel consumptiondata at full laod with diesel fuel with spedci�c gravity of 0.85 andconforming to BS2869: 1998, Class A2.

Definitions

kWkVAkWkVA

Phase Ratings and Performance at 60 Hz, RPM15003

Voltage Prime Standby

Weights & Dimensions

Weights: kg (lb)

Net (+ lube oil)

Wet (+ lube oil & coolant)

Fuel, lube oil & coolant 2548 (5617)

2252 (4965)

2215 (4883)

Dimensions: mm (in)

Height

Width

Length

1718 (67.6)

1003 (39.5)

2960 (116.5)

DocumentsOperation and maintenance manuals provided.Wiring diagrams included.

Quality StandardsBS4999, BS5000, BSEN60034, BSEN61000, IEC60034.

WarrantyAll equipment carried full manufacturer's warranty.

General Data

Market: International

Information contained in this publication may be considered con�dential.Discretion is recommended when distributing.

Materials and speci�cations are subject to change without notice.CAT, CATERPILLAR, their respective logos and ''Caterpillar Yellow'', as well as corporate and product

identity used herein, are trademarks of Caterpillar and may not be used without permission.

www.CAT-ElectricPower.com

© 2007 CaterpillarAll rights reserved.

Printed in U.S.A.

Note: General con�guration not to be usedfor installation. See general dimensiondrawings for detail.

-

LEHF7209-01