Ge Test-standsat MPI Munich
Xiang Liu
1. General 2. Crystals, Test-stands & Results3. Outlook
![Page 2: Ge Test-stands at MPI M unich](https://reader036.fdocuments.in/reader036/viewer/2022062301/568159f6550346895dc74203/html5/thumbnails/2.jpg)
Crystals & Test-stands
Gerda Collab. , Jun 27-29, 2005 Page 2
2 Canberra crystals (for test-stands II & III)Canberra-I : non-true coaxial, no segment (ready & tested)Canberra-II: coaxial, 18 segments, 6 x 3z
3 DSG crystals (for test-stands I & III)DSG-I : true coaxial, no segment (ready)DSG-II : 6 segments (ready)DSG-III: 18 segments, 6 x 3z
3 test-stands:Eurysis test-stand: for Canberra-I & II in LN2 (ready)MPI test-stand: for DSG I II & III in LN2 (almost ready)Vacuum test-stand: for DSG & Canberra crystals (September)
![Page 3: Ge Test-stands at MPI M unich](https://reader036.fdocuments.in/reader036/viewer/2022062301/568159f6550346895dc74203/html5/thumbnails/3.jpg)
Goal
Gerda Collab. , Jun 27-29, 2005 Page 3
With Eurysis & DSG LN2 Test-stands:handling Ge in LN2Ge Properties (resolution etc. with source)Segmentations (coincidence cut for )Pulse shapes (true & non-true coaxial)MC verification (energy, pulse shape)
With Vacuum Test-stand:Dead layer thickness (with laser) source
![Page 4: Ge Test-stands at MPI M unich](https://reader036.fdocuments.in/reader036/viewer/2022062301/568159f6550346895dc74203/html5/thumbnails/4.jpg)
Crystals Canberra-I
Gerda Collab. , Jun 27-29, 2005 Page 4
Canberra-I: non-true coaxial, no segment, mounted on stick
Canberra-II: 6 x 3z
preampcrystal
![Page 5: Ge Test-stands at MPI M unich](https://reader036.fdocuments.in/reader036/viewer/2022062301/568159f6550346895dc74203/html5/thumbnails/5.jpg)
Crystals Canberra-I
Gerda Collab. , Jun 27-29, 2005 Page 5
![Page 6: Ge Test-stands at MPI M unich](https://reader036.fdocuments.in/reader036/viewer/2022062301/568159f6550346895dc74203/html5/thumbnails/6.jpg)
Gerda Collab. , Jun 27-29, 2005 Page 6
Canberra-I Eurysis
Made in EurisysFor Canberra crystals onlyDewar ~50cm H, ~20cm RHeater at top and bottom (to evaporate LN2)Plug & play
heater
source
Gas & LN2
Open for crystal
Safety valve
1st Test-stand: Eurysis Test-stand
![Page 7: Ge Test-stands at MPI M unich](https://reader036.fdocuments.in/reader036/viewer/2022062301/568159f6550346895dc74203/html5/thumbnails/7.jpg)
Eurysis Test-stand operation
Gerda Collab. , Jun 27-29, 2005 Page 7
Canberra-I Eurysis
Steps:1) Fill Dewer with LN2.2) Take Canberra-I out from vacuum can.3) Dip Canberra-I into LN2.4) Apply HV and measure.
Steps after measurement:1) Seal dewer gastight.2) Pump in gas N2 and LN2 out.3) Turn on top & bottom heater.4) Turn on heater around crystal for 2 hours.5) Take out canberra-I and put back to can
and make vacuum.
No condensation on crystal during warmup.
![Page 8: Ge Test-stands at MPI M unich](https://reader036.fdocuments.in/reader036/viewer/2022062301/568159f6550346895dc74203/html5/thumbnails/8.jpg)
Results from Eurysis Test-stand
Gerda Collab. , Jun 27-29, 2005 Page 8
Jun 7th, 2005, Eurysis Test-stand with Canberra-I crystal.
FWHM ~5keV at 1.173MeV, need more investigation.
![Page 9: Ge Test-stands at MPI M unich](https://reader036.fdocuments.in/reader036/viewer/2022062301/568159f6550346895dc74203/html5/thumbnails/9.jpg)
Crystal DSG-I
Gerda Collab. , Jun 27-29, 2005 Page 9
3 Ge crystals from DSG:DSG-I : P-type, true-coaxial, no segment.
![Page 10: Ge Test-stands at MPI M unich](https://reader036.fdocuments.in/reader036/viewer/2022062301/568159f6550346895dc74203/html5/thumbnails/10.jpg)
Crystals DSG-II & III
Gerda Collab. , Jun 27-29, 2005 Page 10
DSG-II : P-type, true-coaxial, 6 phi segments (test at DSG done, now at Munich)
DSG-III: 6phi x 3z
![Page 11: Ge Test-stands at MPI M unich](https://reader036.fdocuments.in/reader036/viewer/2022062301/568159f6550346895dc74203/html5/thumbnails/11.jpg)
2nd Test-stand: MPI Test-stand
Gerda Collab. , Jun 27-29, 2005 Page 11
Similar to Eurysis, made in MPIBigger dewer ~1m H, 30cm RGallow loading crystals.Only for DSG I, II & IIISimilar operating procedure.
Dewer
Hanging strings
Faraday cage
Cover
Crystal model
![Page 12: Ge Test-stands at MPI M unich](https://reader036.fdocuments.in/reader036/viewer/2022062301/568159f6550346895dc74203/html5/thumbnails/12.jpg)
MPI Test-stand Operation
Gerda Collab. , Jun 27-29, 2005 Page 12
Expect the first result within 1-2 weeks.
Load crystal During operation
Critical: no condensation on crystal during warm-up minimize time to remove LN2 and warm up detector. Plan to use little heater.
![Page 13: Ge Test-stands at MPI M unich](https://reader036.fdocuments.in/reader036/viewer/2022062301/568159f6550346895dc74203/html5/thumbnails/13.jpg)
MPI vs. Eurysis Teststand
Gerda Collab. , Jun 27-29, 2005 Page 13
In principle, can dip Canberra crystal into MPI test-stand, & v.v.Same physics tests
MPI test-stand has many advantages: closer to Gerda design (mini-Gerda), can test support strings & cable in LN2.built in house, easy to modify according to new requirement.Support strings flexible, can hang 2 crystals together and take coincidence data.Test-stand built in house, cost “no” money.
vs.
![Page 14: Ge Test-stands at MPI M unich](https://reader036.fdocuments.in/reader036/viewer/2022062301/568159f6550346895dc74203/html5/thumbnails/14.jpg)
3rd Test-stand: Vacuum Test-stand
Gerda Collab. , Jun 27-29, 2005 Page 14
Vacuum tanks
![Page 15: Ge Test-stands at MPI M unich](https://reader036.fdocuments.in/reader036/viewer/2022062301/568159f6550346895dc74203/html5/thumbnails/15.jpg)
Vacuum Test-stand
Gerda Collab. , Jun 27-29, 2005 Page 15
3 stations mounted togetherSources move in 3D around crystalCrystal fixed & cooled through LN2 pipesFor both Canberra & DSG crystals, sources & laser can be usedExpect first run September
![Page 16: Ge Test-stands at MPI M unich](https://reader036.fdocuments.in/reader036/viewer/2022062301/568159f6550346895dc74203/html5/thumbnails/16.jpg)
DAQ
Gerda Collab. , Jun 27-29, 2005 Page 16
XIA Pixie-4.On board PC.Each card reads 4 channels.14bit ADC, 75MHz spc.for pulse shape.
PC Pixie card NIM cards for HV and preamp. power supply
![Page 17: Ge Test-stands at MPI M unich](https://reader036.fdocuments.in/reader036/viewer/2022062301/568159f6550346895dc74203/html5/thumbnails/17.jpg)
Outlook
Gerda Collab. , Jun 27-29, 2005 Page 17
Eurisys Test-stand:More study with Canberra-I, solve resolution problem.Canberra-II detector end of this year
MPI Test-stand:DSG-I 1-2 week. True coaxial, good for pulse shapes.DSG-II crystal ready, 1-2 week, study segments and more pulse shapes.DSG-III arrive end of this year
Vacuum Test-stand:Start data taking SeptemberStudy dead layer with laser, hadronic interaction with sources.
![Page 18: Ge Test-stands at MPI M unich](https://reader036.fdocuments.in/reader036/viewer/2022062301/568159f6550346895dc74203/html5/thumbnails/18.jpg)
Conclusion
Gerda Collab. , Jun 27-29, 2005 Page 18
Many test stand setups:Different crystals, non-true, true-coaxial, none, 6 & 18 segments.Different environment, LN2, Vacuum.Different sources, , & laser
Rich physics will be explored: Ge general properties.EM & hadron interactions.Pulse shape.All with MC simulations.
Any suggestions, ideas about measurement, simulation, please contact us!