GE Monogram ®
Installation
Instructions
36" Vent Hood
Model
ZV750
Monogram°
Before you begin--Read these insuucfions completely and careflflly.IMPORTANT: Save these insuuctions for local inspector's use.IMPORTANT: OBSERVE ALL GOVERNING CODES AND ORDINANCES.NOTE TO INSTALLER: Be sure to leave these instructions with the ConsumeL
NOTE TO CONSUMER: Keep these insuucfions with your Owner's Manual forflmlre reference.
V!lw_,_:mh,[_This appliance must be properly grounded. See "Electrical Supply", page 4. I
If you have questions concerning theinstallation of tiffs product, call the GE AnswerCenter _>Consumer Information Service at
800.626.2000, 24 hours a day, 7 days a week.If you received a damaged vent hood, youshould contact your dealeLCAUTION!
Due to the weight and size of these vent hoodsand to reduce the risk of personal i_jury ordamage to the product, TWO PEOPLE AREREQ,UIRED FOR PROPER INSTAI,IATION._i_ARNING!
To reduce the risk of fire or elecuic shock,
do not use tiffs range hood with any externalsolid-state speed conuol device. Any suchalteration flom original factory wiring couldresult in damage to the unit and/or create anelecuical safety hazard.To reduce the risk of fire and to properlyexhaust air, be sure to duct air outdoors. Do
not vent exhaust air into spaces wittfin walls orceilings or into attics, crawl spaces or garages._i_SkRNING: TO REDUCE THE RISK OF FIRE,USE ONIX METAl, DUCTWORK
TO REDUCE THE RISK OF FIRE, EI,ECTRIC
SHOCK OR INJURY TO PERSONS,
OBSERVE THE FOI,I,OWING:
A. Use tiffs unit only in the manner intendedby the manufacturer. If you have anyquestions, contact the manufacturer.B. Before servicing or cleaning unit, switchpower off at service panel and lock servicepanel to prevent power flom being switchedon accidentally. If the service panel cannot belocked, fasten a tag or prominent warninglabel to the panel.For general ventilating use only. Do not useto exhaust hazardous or explosive materialsand vapors.Installation work and elecuical wiring must bedone by qualified person (s) in accordance withall applicable codes and standards includingfire-rated construction.
Sufficient air is needed for proper combustionand exhausting of gases through the flue(clfimney) of tirol burning equipment toprevent back drafting. Follow the heatingequipment manufacturer's guidelines andsafety standards such as those published by theNational Fire Protection Association (NFPA),and the American Society for Heating,Refligevadon and Air Conditioning Engineers(ASHRAE), and the local code authorities.
Contents Design InformationModel Available ................................................................................................................................... 3
Optional Accessories ........................................................................................................................... 3Product Dimensions & Clearances .................................................................................................... 3
Advance Planning ............................................................................................................................... 4
Electrical Supply .................................................................................................................................. 4
Installation PreparationDuct Fittings ........................................................................................................................................ 5Tools and Materials Required ............................................................................................................. 6Step 1: Remove the Packaging ............................................................................................................ 6
Installation
Step 2: Check Installation Hardware .................................................................................................. 7Step 3: Ductwork, Wiring, Hood Attachment I,ocations .................................................................. 7Step 4: Install Mounting Brackets ....................................................................................................... 8Step 5: Install the Hood ...................................................................................................................... 8Step 6: Install Duct Bracket ................................................................................................................. 9Step 7: Connect Ductwork ................................................................................................................ 10Step 8: Connect Elecuical ................................................................................................................. 10Step 9: Install Decorative Duct Cover and Utility Bars .................................................................... 10Step 10: Install Filters ........................................................................................................................ 11Step 11: Finalize Installation ............................................................................................................. 11
Design Intormation
36" Vent Hood
ModelAvailable
Model
ZV750This vent hood is designed to be used invented installations.
A decorative duct cover is provided to cover
the duct flom tile top of tile hood to an 8 ft.
or 9 ft. ceiling.
OptionalAccessories
Model
ZX 10SY
An optional stainless steel duct cover is
available for 9 ft. to 10 ft. ceiling installations.
(Tile supplied duct covet is sized to reach 8 ft.
to 9 ft. ceilings.) Order tile optional ductcovet at tile same time as tile vent hood and
have on site before installation.
Product
Dimensions& Clearances
Tile vent hood Illttst be installed 24 and 0 inax.
above tile cooking surface. 25-1/2" is recommended to _[ ;insure that tile duct cover meets tile ceiling. Tile cooking [
surface should be at least, 6 above tile floor. Installatton | i
will be easier if tile vent hood is installed before tile range | _Height
tooi,,,n or cooktop a ntertop is installed.
8-1/4"
, 34-5/8" * i
21-5/8"
o
"25-1/2" Recommended
t J
l oo
o
o
o
o36" Min.
*The distance between the cooking surface and the bottomof the hood must be at least 24" and upto 36". The25-1/2"recommended installation height, above the standard36"ceuntertep, will insure duct cover fit to the ceiling.
"26-1/4" for 8 ft. ceiling
38-1/4" for 9 ft. ceiling
38-1/4" to 50-1/4" for 9 ft. to
10 ft. ceiling using optional
accessoryZX16SYDuct Cover
Recirculating OperationThis hood may be installed forrecirculating operation. One of tilefollowing kits is required and must beordered with tile hood.
ZXR758 - For lap to 9 ft. ceiling height.ZXR7510 - For up to 10 ft. ceiling height.Both tile hood and accessory must be onsite at tile time of installation. Follow tile
installation instructions packed with tileaccessory to complete tile installation.
Design Information
36" Vent Hood
Advance
Plannin
Using Duct Cover Accessories
• A duct cover accesso_ y may be required foryour hood installation height. Refer to thischart to determine the need for the ZX10SY
accessoiy.
ZV750SYDuctCoverDimensionsHoodandAccessory A BZX750SY 18-7/8" 22-13/16"
ZX10SY - 34-1/4"
9-!!
11-7/8"
/4" ,
Ductwork
• Determine the exact location of the vent hood.
• Plan the route for venting exhaust to theoutdoors.
• Use the shortest and straightest duct route
possible. For satisfactory performance, duct run
should not exceed 100 feet equivalent length for
any duct configurations.
• Refer to "Duct Fittings" chart to compute the
maximum permissable length for duct runs to theoutdoors.
• Install a wall cap with damper or roof cap at the
exterior opening.
ZV750SYInstallationHeightsActual
Ceiling * PossibleHood
Heitlht InstallationHeight7' 11" 24-1/2"8'O" 25-I/2"
8'1" 25-1/2"to26-1/2"
8'2" 25-1/2"to27-1/2"
8'3" 25-1/2"to28-1/2"8'4" 25-1/2"to29-1/2"
8'5" 25-1/2"to30"
8'6" 25-1/2"to30"
8'7" 25-I/2"to30"
8'8" 25-1/2"to30"8'9" 25-1/2"to30"
8'10" 25-1/2"to30"
8'11" 25-I/2"to 30"
9' O" 25-1/2" to 30"9' 1" 25-1/2" to 30"9' 2" 25-1/2" to 30"9' 3" 25-1/2" to 30"9' 4" 25-1/2" to 30"9' 5" 25-1/2" to 30"9' 6" 25-1/2" to 30"9' 7" 25-1/2" to 30"9' 8" 25-1/2" to 30"9' 9" 25-1/2" to 30"9' 10" 25-1/2" to 30"9' 11" 25-1/2" to 30"10'0" 25-1/2"to30"
Duct Cover
t_LU
...JCLCL
03
>-O30
XN>-fr-oQ3Q3LUrj¢,3
<
* Based on 36" countertop height.
Electrical
Supply Warning, forPersonal Safety:Remove house time or opencircuit breaker before beginninginstallation.
Do not use an extension cord or adapterplug with this appliance. Follow NationalElecuical Code or prevailing local codesand ordinances.
• Gonnect the wiring to the house wiring inaccordance with local codes.
Grounding Instruction
The giounding conductor must be connected to
a ground metal, permanent wiring system, or an
equipment-grounding terminal or lead on thehood.
Electrical supply
This vent hood must be supplied with 120V,
60Hz., and connected to an individual, properly
grounded branch circuit, protected by a 15 or 20
ampere circuit breaker or time delay fllse.
• Wiring must be 2 wire with ground.
• If the electrical supply does not meet the
above requirements, call a licensed elecuician
before proceeding.
• Route wiring as close to the installation
location as possible, in the ceiling or soffit.
Warning: The improper
connection of the equipment-grounding conductor can result ina risk of electric shock. Check with
a qualified electrician or servicerepresentative if you are in doubt whetherthe appliance is properly grounded.
Installation Preparation
36" Vent Hood
Duct
fittings
Use this chart to
compute maximum
permissable lengthsfor duct runs to
outdoors.
Note: Do not exceed
maximum permissableequivalent lengths!
Maximumductlength:100footfor rangehoods.
Flexible ducting:If flexible metal
ducting is used, all
the equivalent feetvalues in the ruble
should be doubled.
The flexible metal
duct should be
straight and smoothand extended as
much as possible.
Do NOT use flexible
plastic ducting.
Note: Any home ventilationsystem, such as a ventilationhood, may interrupt the properflow of combustion air and
exhaust required by fireplaces,gas furnaces, gas waterheaters and other naturallyvented systems. Tominimize thechance of interruption of suchnaturally vented systems,followthe heating equipmentmanufacturer's guidelines andsafety standards such as thosepublished by NFPA andASHRAE.
Duct Piece
%
%>
Dimensions
RotlI](1,
straight
3-1/4" x l 0"
straight
Equivalent QuantityI,ength* Usedlit.
(per foot
length)
lit.
(per foot
length)
90 ° elbow 12 It.
45 ° elbow 7 It.
3-1/4" x 10" 14ft.
3-1/4" x 12" l0 It.
90 ° elbow
3-1/4" x 10" 8 ft.
3-1/4" x 12" 6ft.
45 ° elbow
3-1/4" x 10" 33 It.
3-1/4" x 12" 24 It.
90 ° flat elbow
()" I'OtlIld to
rectangular 2 It,
Total
EquivalentI,ength
©
Rectangularto 6" round 2 It.
3-1/4" x 10" 4 ft.
3-1/4" x 12" 4 ft.
()" I'OLIHd tO
rectangulartransition 90 ° elbow
3-1/4" x 10" 4 It.
3-1/4" x 12" 4ft.
Rectangular to 6" round
transition 90 ° elbow
Round
wall cap
with damper 24 It.
3-1/4" x 10" 24 ft.
3-1/4" x 12" 18ft.
Rectangular wall cap
with damper
Round roof cap 33 ft.
*Actual length of straight duct plus duct fittingequivalent. Equivalent length of duct pieces arebased on actual tests conducted by 6E EvaluationEngineering and reflect requirements for goodventing performance with any ventilation hood.
Total Duct Run
Installation Preparation
36" Vent Hood
7bols &Materials
Required(not supplied)
• Tape measure• I_dfe
• Spirit level• Wire cutter
• Wire suipper• Wire ntlts
• Electric drill and appropriate bits• Phillips screwdriver• Flat blade screwdriver• Hammer• Pliers
• Safety glasses• Tape to mount template• Gloves to protect against sharp edges• 120V 60Hz. 15 oI 20 Amp, 2 wire with
gIound. PIoperly grounded branch circuit.• Suain relief forj unction box.• 6" round metal duct work.
Remove the
Paekacin¢
The vent hood is shipped secured to a shippingboard with 4 screws.
• Remove the duct covm, parts box andstyiofoam packaging.
• I,ift the hood out of the box, using hand gripson both sides of the shipping board.
• Remove and properly discard the plasticwiapping.
• I,ocate and remove 2 sciews at the top of theassembly and 2 screws inside the hood behindthe filter guides on the left and right sides.Discard the shipping board.
• Remove junction box cover.• Remove knockout flomjunction box.• Install suain relief onto junction box.
JunctionBox
Knockout
MountincScrew
ShippingBoard
..... MountingScrew
ShippingBoard
Screw
Installation
36" Vent Hood
CheckInstallationHardware
Ductwork,
Wiring,HoodAttachment
Locations
I,ocate tim hardware accessory box packedwith range hood and check contents.
10
WallFasteners
2 MountingBrackets
iFTPh,,,, eadScrews
Utility Barswith Screws 3 Filters
_-x
2 LargeFlatWashers
lOWoodScrews
DecorativeDuct
Wall Mount Template
To determine ductwork locations:
• I,ocate the template packed with theliterature.
• Determine tim exact installation location.
- Measure 36" flom tim floor to tim top
of the cooking surface. Add 25-1/2"
recommended space flom the cookingsurface to bottom of hood. Mark that
location.
- Use a level to draw a straight pencil lineon tim wall.
- Tape tim template in position along the
penciled line. CHECK TO BE SURETEMPI,ATE IS I,EVEI,.
• Measure flom the peak of the hood
to the ceiling as indicated. The dimensionshould be:
- 26-1/4" to 38-1/4" for 8 ft. to 9 ft. ceilings.- 38-1/4" to 50-1/4" for 9 ft. to 10 ft.
ceilings (This installation requires
ZX10SY accesso_ T duct covet,)
CEILING DUCTING
If ductwork will vent straight tap to tim ceiling:• Use a level to draw a line straight tap, flom
,/FOB CEILING
3 1/2" Wall',./VENT_ DUCTINGCenterlineTo/r"
6-1/2"Die.Hole_,,
\\\\\ i
X J. .Centerline
2{,_ 6' Min.AboveFOBWALLVENTDUCT [ BracketLocation
i
i
i
WALL DUCTING
If ductwork will vent to the rear:
• Use tim level to draw a line suaight tap flom
the centerline on the template.• Measure at least 6" above tim bracket location
shown on tim template to tim centerline of
the 6-1/2" dia. duct hole. (Hole may need to
be elongated for duct elbow.)
the centerline on the template to the ceiling. HOUSE WIRING LOCATION:• Measure 3-1/2" fiom the back wall to the
centerline of a 6-1/2" dia. hole on the
ceiling. •Note: If drywallis notpresent,adddrywallthicknessto the3-1/2"dimension.
The junction box is located on the top of the
hood, at tim flont right side.
Rotate house wiring as close to tim installation
location as possible, through the ceiling, soffit
or back wall. Wiring should enter at least 4"
above tim bracket on tim right side. 7
Installation
36" Vent Hood
s4Install
MountingBrackets
Whenever possible, the vent hood should besecured to wall studs.
• XVith the template roped in place, use apuncll to mark all mounting screw locations.
• Drill 1/8" pilot holes at the 6 punchedlocations.
• Remove the template.• Enlarge holes that did not enter studs to
3/8" and tap anchors for wall fasteners intothe holes.- Drive screws into the fasteners to allow
anchors to expand against the wallmaterial. Remove the screws for finalinstallation.
• Secure the mounting brackets to the wallstuds with wood screws provided.- For hollow walls, secure the mounting
brackets through the anchors.
1Note:Screws "A" and "B" are pre-assembledonto the brackets.Do not remove these screws.
Installthe Hood
Place the hood on the brackets and slide left to
right to align with rectangular slots at the top.
• Adjust the installation height by tightening
or loosening the screws "A" at the bottomof the brackets.
• Align the hood lower mounting holes with
pilot holes in the wall.
• Using two large fiat washers (supplied),
install wood screws or wall fastener screws,
loosely, into lower mounting holes. Do not
tighten.
• I,evel the hood by tightening or looseningthe screws "A" located on the bottom
mounting brackets.
• Tighten the lower mounting screws.
• Tighten screws "B" located at the top of the
mounting bracket against the hood to clamp
the position. Do not overtighten screws.
Screws"B"ToSecureHood
ToWall/--...
--Leveland
HeightAdjustmentScrews"A"
Lower
MountingScrews
Installation
36" Vent Hood
Install Duct
Bracket
(jbr vertical exhaust)
Install the 2 small screws into tile sides of
tile duct bracket. Remove tile screws. This
will insure ease of final installation.
Temporarily install a piece of 6" duct cut to
length between tile hood oudet and tile
ductwork at tile ceiling.
Position tile upper duct bracket behind tile
duct and against tile wall and ceiling.Use a level to check that duct is vertical and
duct bracket is centered.
Mark tile 4 screw locations of tile bracket.
Remove tile bracket and temporary ductsection.
Drill 1/8" pilot holes ill marked bracketlocation.
If pilot holes do not enter studs, enlarge tileholes 3/8" and install wall fastener anchors.Drive screws into tile
fasteners to allow anchors
to expand against tile wallmaterial. Remove tile screws. ,_"Secure tile bracket to tile
ceiling and wall with woodscrews and/or wall fastener
screws.
\
DuctWork
Install Duct
Bracket
(jbrho_4zo'ntalexhaust)
Tile upper duct bracket should be installed againsttile ceiling. This bracket will hold tile decorativeduct cover ill place at tile top.• Install tile 2 small screws into tile sides of tile duct
bracket. Remove the screws. This will insure easeof final installation.
• Position tile bracket against tile wall and ceiling.Center tile bracket using marked centerline oftile hood.
• Use a pencil to mark tile bracket location alongits outside edges.
• Temporarily place the decorative duct cover ontop of tile hood and extend tile inner portion tomeet tile ceiling.
• Tile duct cover should be level and align withmarks for bracket.
• Remove tile duct coveL
• Place bracket against marked location and marktile 4 screw locations.
• Drill 1/8" pilot holes ill marked location.• If pilot holes do not enter studs, enlarge tile
holes 3/8" and install wall fastener anchors.Drive screws into tile fasteners to allow anchors
to expand against tile wall material. Removetile screws.
• Secure tile bracket to tile ceiling and wall withwood screws and/or wall fastener screws.
I
I
t/ I \I 1
\ I !
Installation
36" Vent Hood
ConnectDuctwork
Do not use sheet metal
screws at hood flange
connection. Doing so will prevent proper
damper operation. Seal connection with
rope only.
Install ductwork, making connections indirection of airflow as illustrated.
Secure joints in ductwork with sheeunemlscrews.
Wrap all duct joints with duct rope for
airtight seal.
Duct TapeOver Seam
and Screw
Air Flow
Screw
Step 8
ConnectElectrical
Verify that power is turned off at the source.
If house wiring is not 2-wire witha ground wire, a ground must beprovided by the insmlleLWhen house wiring is aluminum,be sure to use U.I,. approvedanti-oxidant compound andaluminum-to-copper connectors.
• Insert house wiring through suain reliefand tighten.
• Connect white leads to branch circuitwhite lead.
• Connect black leads to branch circuitblack lead.
• Connect green/yellow leads to branchcircuit green or bare ground lead.
• Secure all connections with wire ntlts oileach electrical connectoL
• Push wires into junction box and replacecoveL Be sure wires are not pinched.
Step 9InstallDecorativeDuct Coverand
UtilityBars
1o
Mounting Screws
/ Notches
Place the decorative duct cover on top ofthe hood.
• Insert the lower portion of the duct coverinto the impression on the top of the hood.
• Extend the inner duct upwards to meet theceiling and bracket.
• Secure the duct cover to the bracket with
the 2 small Phillips screws provided.• Install the side utility bars as shown with
screws provided.
Install Optional ZXl OSY Duct Cover• Separate the supplied duct cover into
pieces. Discard the upper (or inner)section.
• Insert the new ZX10SY duct cover into
the original lower section. Be sure that
the new longer section is inside the shorter
original section. The notches will be at the
bottom and the screw holes at the top asillustrated.
• Follow the same procedures shown aboveto install the new duct cover.
Installation
36" Vent Hood
elOInstall Filters
Remove protective film on filters.
Tip the filter into the lower slots at the
rear of the opening, lift the filter and pullthe knob forward until the filter rests on
the slots.
• To remove the filters, grasp the knob andpush the filter towards the rear and tiltdownwards.
e llFinalizeInstallation
• Remove protective film covering the controlpanel on the flont face of the hood and anyremaining packaging materials.
• Refer to the Owner's Manual for
operating instructions.
11
Monogram:GEConsumer& IndustrialGEAppliancesGeneralElectricCompanyLouisville,KY40225
monogram.corn
©2007GECompany
Note: \,_ hile perfl_rming installations described in this
book, satety glasses or goggles should be _orn.
For ,\hn_ogram local service i_ 3our area, call1.800.444. 1845.
NOTE: Product improvement is a contimdng endea\_r at General Electric.
There[k_re. materials, appearance and specit3cations are subject to change
without notice.
Pub. No. 49-899{)-9