GE Monogram ® Installation Instructions 36" Vent Hood Model ZV750 Monogram°

Transcript of GE Monogram ® Instructionsinstallation of tiffs product, call the GE Answer Center _>Consumer...

Page 1: GE Monogram ® Instructionsinstallation of tiffs product, call the GE Answer Center _>Consumer Information Service at 800.626.2000, 24 hours a day, 7 days a week. If you received a

GE Monogram ®

Installation

Instructions

36" Vent Hood

Model

ZV750

Monogram°

Page 2: GE Monogram ® Instructionsinstallation of tiffs product, call the GE Answer Center _>Consumer Information Service at 800.626.2000, 24 hours a day, 7 days a week. If you received a

Before you begin--Read these insuucfions completely and careflflly.IMPORTANT: Save these insuuctions for local inspector's use.IMPORTANT: OBSERVE ALL GOVERNING CODES AND ORDINANCES.NOTE TO INSTALLER: Be sure to leave these instructions with the ConsumeL

NOTE TO CONSUMER: Keep these insuucfions with your Owner's Manual forflmlre reference.

V!lw_,_:mh,[_This appliance must be properly grounded. See "Electrical Supply", page 4. I

If you have questions concerning theinstallation of tiffs product, call the GE AnswerCenter _>Consumer Information Service at

800.626.2000, 24 hours a day, 7 days a week.If you received a damaged vent hood, youshould contact your dealeLCAUTION!

Due to the weight and size of these vent hoodsand to reduce the risk of personal i_jury ordamage to the product, TWO PEOPLE AREREQ,UIRED FOR PROPER INSTAI,IATION._i_ARNING!

To reduce the risk of fire or elecuic shock,

do not use tiffs range hood with any externalsolid-state speed conuol device. Any suchalteration flom original factory wiring couldresult in damage to the unit and/or create anelecuical safety hazard.To reduce the risk of fire and to properlyexhaust air, be sure to duct air outdoors. Do

not vent exhaust air into spaces wittfin walls orceilings or into attics, crawl spaces or garages._i_SkRNING: TO REDUCE THE RISK OF FIRE,USE ONIX METAl, DUCTWORK

TO REDUCE THE RISK OF FIRE, EI,ECTRIC

SHOCK OR INJURY TO PERSONS,

OBSERVE THE FOI,I,OWING:

A. Use tiffs unit only in the manner intendedby the manufacturer. If you have anyquestions, contact the manufacturer.B. Before servicing or cleaning unit, switchpower off at service panel and lock servicepanel to prevent power flom being switchedon accidentally. If the service panel cannot belocked, fasten a tag or prominent warninglabel to the panel.For general ventilating use only. Do not useto exhaust hazardous or explosive materialsand vapors.Installation work and elecuical wiring must bedone by qualified person (s) in accordance withall applicable codes and standards includingfire-rated construction.

Sufficient air is needed for proper combustionand exhausting of gases through the flue(clfimney) of tirol burning equipment toprevent back drafting. Follow the heatingequipment manufacturer's guidelines andsafety standards such as those published by theNational Fire Protection Association (NFPA),and the American Society for Heating,Refligevadon and Air Conditioning Engineers(ASHRAE), and the local code authorities.

Contents Design InformationModel Available ................................................................................................................................... 3

Optional Accessories ........................................................................................................................... 3Product Dimensions & Clearances .................................................................................................... 3

Advance Planning ............................................................................................................................... 4

Electrical Supply .................................................................................................................................. 4

Installation PreparationDuct Fittings ........................................................................................................................................ 5Tools and Materials Required ............................................................................................................. 6Step 1: Remove the Packaging ............................................................................................................ 6

Installation

Step 2: Check Installation Hardware .................................................................................................. 7Step 3: Ductwork, Wiring, Hood Attachment I,ocations .................................................................. 7Step 4: Install Mounting Brackets ....................................................................................................... 8Step 5: Install the Hood ...................................................................................................................... 8Step 6: Install Duct Bracket ................................................................................................................. 9Step 7: Connect Ductwork ................................................................................................................ 10Step 8: Connect Elecuical ................................................................................................................. 10Step 9: Install Decorative Duct Cover and Utility Bars .................................................................... 10Step 10: Install Filters ........................................................................................................................ 11Step 11: Finalize Installation ............................................................................................................. 11

Page 3: GE Monogram ® Instructionsinstallation of tiffs product, call the GE Answer Center _>Consumer Information Service at 800.626.2000, 24 hours a day, 7 days a week. If you received a

Design Intormation

36" Vent Hood

ModelAvailable

Model

ZV750This vent hood is designed to be used invented installations.

A decorative duct cover is provided to cover

the duct flom tile top of tile hood to an 8 ft.

or 9 ft. ceiling.

OptionalAccessories

Model

ZX 10SY

An optional stainless steel duct cover is

available for 9 ft. to 10 ft. ceiling installations.

(Tile supplied duct covet is sized to reach 8 ft.

to 9 ft. ceilings.) Order tile optional ductcovet at tile same time as tile vent hood and

have on site before installation.

Product

Dimensions& Clearances

Tile vent hood Illttst be installed 24 and 0 inax.

above tile cooking surface. 25-1/2" is recommended to _[ ;insure that tile duct cover meets tile ceiling. Tile cooking [

surface should be at least, 6 above tile floor. Installatton | i

will be easier if tile vent hood is installed before tile range | _Height

tooi,,,n or cooktop a ntertop is installed.

8-1/4"

, 34-5/8" * i

21-5/8"

o

"25-1/2" Recommended

t J

l oo

o

o

o

o36" Min.

*The distance between the cooking surface and the bottomof the hood must be at least 24" and upto 36". The25-1/2"recommended installation height, above the standard36"ceuntertep, will insure duct cover fit to the ceiling.

"26-1/4" for 8 ft. ceiling

38-1/4" for 9 ft. ceiling

38-1/4" to 50-1/4" for 9 ft. to

10 ft. ceiling using optional

accessoryZX16SYDuct Cover

Recirculating OperationThis hood may be installed forrecirculating operation. One of tilefollowing kits is required and must beordered with tile hood.

ZXR758 - For lap to 9 ft. ceiling height.ZXR7510 - For up to 10 ft. ceiling height.Both tile hood and accessory must be onsite at tile time of installation. Follow tile

installation instructions packed with tileaccessory to complete tile installation.

Page 4: GE Monogram ® Instructionsinstallation of tiffs product, call the GE Answer Center _>Consumer Information Service at 800.626.2000, 24 hours a day, 7 days a week. If you received a

Design Information

36" Vent Hood

Advance

Plannin

Using Duct Cover Accessories

• A duct cover accesso_ y may be required foryour hood installation height. Refer to thischart to determine the need for the ZX10SY

accessoiy.

ZV750SYDuctCoverDimensionsHoodandAccessory A BZX750SY 18-7/8" 22-13/16"

ZX10SY - 34-1/4"

9-!!

11-7/8"

/4" ,

Ductwork

• Determine the exact location of the vent hood.

• Plan the route for venting exhaust to theoutdoors.

• Use the shortest and straightest duct route

possible. For satisfactory performance, duct run

should not exceed 100 feet equivalent length for

any duct configurations.

• Refer to "Duct Fittings" chart to compute the

maximum permissable length for duct runs to theoutdoors.

• Install a wall cap with damper or roof cap at the

exterior opening.

ZV750SYInstallationHeightsActual

Ceiling * PossibleHood

Heitlht InstallationHeight7' 11" 24-1/2"8'O" 25-I/2"

8'1" 25-1/2"to26-1/2"

8'2" 25-1/2"to27-1/2"

8'3" 25-1/2"to28-1/2"8'4" 25-1/2"to29-1/2"

8'5" 25-1/2"to30"

8'6" 25-1/2"to30"

8'7" 25-I/2"to30"

8'8" 25-1/2"to30"8'9" 25-1/2"to30"

8'10" 25-1/2"to30"

8'11" 25-I/2"to 30"

9' O" 25-1/2" to 30"9' 1" 25-1/2" to 30"9' 2" 25-1/2" to 30"9' 3" 25-1/2" to 30"9' 4" 25-1/2" to 30"9' 5" 25-1/2" to 30"9' 6" 25-1/2" to 30"9' 7" 25-1/2" to 30"9' 8" 25-1/2" to 30"9' 9" 25-1/2" to 30"9' 10" 25-1/2" to 30"9' 11" 25-1/2" to 30"10'0" 25-1/2"to30"

Duct Cover

t_LU

...JCLCL

03

>-O30

XN>-fr-oQ3Q3LUrj¢,3

<

* Based on 36" countertop height.

Electrical

Supply Warning, forPersonal Safety:Remove house time or opencircuit breaker before beginninginstallation.

Do not use an extension cord or adapterplug with this appliance. Follow NationalElecuical Code or prevailing local codesand ordinances.

• Gonnect the wiring to the house wiring inaccordance with local codes.

Grounding Instruction

The giounding conductor must be connected to

a ground metal, permanent wiring system, or an

equipment-grounding terminal or lead on thehood.

Electrical supply

This vent hood must be supplied with 120V,

60Hz., and connected to an individual, properly

grounded branch circuit, protected by a 15 or 20

ampere circuit breaker or time delay fllse.

• Wiring must be 2 wire with ground.

• If the electrical supply does not meet the

above requirements, call a licensed elecuician

before proceeding.

• Route wiring as close to the installation

location as possible, in the ceiling or soffit.

Warning: The improper

connection of the equipment-grounding conductor can result ina risk of electric shock. Check with

a qualified electrician or servicerepresentative if you are in doubt whetherthe appliance is properly grounded.

Page 5: GE Monogram ® Instructionsinstallation of tiffs product, call the GE Answer Center _>Consumer Information Service at 800.626.2000, 24 hours a day, 7 days a week. If you received a

Installation Preparation

36" Vent Hood

Duct

fittings

Use this chart to

compute maximum

permissable lengthsfor duct runs to

outdoors.

Note: Do not exceed

maximum permissableequivalent lengths!

Maximumductlength:100footfor rangehoods.

Flexible ducting:If flexible metal

ducting is used, all

the equivalent feetvalues in the ruble

should be doubled.

The flexible metal

duct should be

straight and smoothand extended as

much as possible.

Do NOT use flexible

plastic ducting.

Note: Any home ventilationsystem, such as a ventilationhood, may interrupt the properflow of combustion air and

exhaust required by fireplaces,gas furnaces, gas waterheaters and other naturallyvented systems. Tominimize thechance of interruption of suchnaturally vented systems,followthe heating equipmentmanufacturer's guidelines andsafety standards such as thosepublished by NFPA andASHRAE.

Duct Piece

%

%>

Dimensions

RotlI](1,

straight

3-1/4" x l 0"

straight

Equivalent QuantityI,ength* Usedlit.

(per foot

length)

lit.

(per foot

length)

90 ° elbow 12 It.

45 ° elbow 7 It.

3-1/4" x 10" 14ft.

3-1/4" x 12" l0 It.

90 ° elbow

3-1/4" x 10" 8 ft.

3-1/4" x 12" 6ft.

45 ° elbow

3-1/4" x 10" 33 It.

3-1/4" x 12" 24 It.

90 ° flat elbow

()" I'OtlIld to

rectangular 2 It,

Total

EquivalentI,ength

©

Rectangularto 6" round 2 It.

3-1/4" x 10" 4 ft.

3-1/4" x 12" 4 ft.

()" I'OLIHd tO

rectangulartransition 90 ° elbow

3-1/4" x 10" 4 It.

3-1/4" x 12" 4ft.

Rectangular to 6" round

transition 90 ° elbow

Round

wall cap

with damper 24 It.

3-1/4" x 10" 24 ft.

3-1/4" x 12" 18ft.

Rectangular wall cap

with damper

Round roof cap 33 ft.

*Actual length of straight duct plus duct fittingequivalent. Equivalent length of duct pieces arebased on actual tests conducted by 6E EvaluationEngineering and reflect requirements for goodventing performance with any ventilation hood.

Total Duct Run

Page 6: GE Monogram ® Instructionsinstallation of tiffs product, call the GE Answer Center _>Consumer Information Service at 800.626.2000, 24 hours a day, 7 days a week. If you received a

Installation Preparation

36" Vent Hood

7bols &Materials

Required(not supplied)

• Tape measure• I_dfe

• Spirit level• Wire cutter

• Wire suipper• Wire ntlts

• Electric drill and appropriate bits• Phillips screwdriver• Flat blade screwdriver• Hammer• Pliers

• Safety glasses• Tape to mount template• Gloves to protect against sharp edges• 120V 60Hz. 15 oI 20 Amp, 2 wire with

gIound. PIoperly grounded branch circuit.• Suain relief forj unction box.• 6" round metal duct work.

Remove the

Paekacin¢

The vent hood is shipped secured to a shippingboard with 4 screws.

• Remove the duct covm, parts box andstyiofoam packaging.

• I,ift the hood out of the box, using hand gripson both sides of the shipping board.

• Remove and properly discard the plasticwiapping.

• I,ocate and remove 2 sciews at the top of theassembly and 2 screws inside the hood behindthe filter guides on the left and right sides.Discard the shipping board.

• Remove junction box cover.• Remove knockout flomjunction box.• Install suain relief onto junction box.

JunctionBox

Knockout

MountincScrew

ShippingBoard

..... MountingScrew

ShippingBoard

Screw

Page 7: GE Monogram ® Instructionsinstallation of tiffs product, call the GE Answer Center _>Consumer Information Service at 800.626.2000, 24 hours a day, 7 days a week. If you received a

Installation

36" Vent Hood

CheckInstallationHardware

Ductwork,

Wiring,HoodAttachment

Locations

I,ocate tim hardware accessory box packedwith range hood and check contents.

10

WallFasteners

2 MountingBrackets

iFTPh,,,, eadScrews

Utility Barswith Screws 3 Filters

_-x

2 LargeFlatWashers

lOWoodScrews

DecorativeDuct

Wall Mount Template

To determine ductwork locations:

• I,ocate the template packed with theliterature.

• Determine tim exact installation location.

- Measure 36" flom tim floor to tim top

of the cooking surface. Add 25-1/2"

recommended space flom the cookingsurface to bottom of hood. Mark that

location.

- Use a level to draw a straight pencil lineon tim wall.

- Tape tim template in position along the

penciled line. CHECK TO BE SURETEMPI,ATE IS I,EVEI,.

• Measure flom the peak of the hood

to the ceiling as indicated. The dimensionshould be:

- 26-1/4" to 38-1/4" for 8 ft. to 9 ft. ceilings.- 38-1/4" to 50-1/4" for 9 ft. to 10 ft.

ceilings (This installation requires

ZX10SY accesso_ T duct covet,)

CEILING DUCTING

If ductwork will vent straight tap to tim ceiling:• Use a level to draw a line straight tap, flom

,/FOB CEILING

3 1/2" Wall',./VENT_ DUCTINGCenterlineTo/r"

6-1/2"Die.Hole_,,

\\\\\ i

X J. .Centerline

2{,_ 6' Min.AboveFOBWALLVENTDUCT [ BracketLocation

i

i

i

WALL DUCTING

If ductwork will vent to the rear:

• Use tim level to draw a line suaight tap flom

the centerline on the template.• Measure at least 6" above tim bracket location

shown on tim template to tim centerline of

the 6-1/2" dia. duct hole. (Hole may need to

be elongated for duct elbow.)

the centerline on the template to the ceiling. HOUSE WIRING LOCATION:• Measure 3-1/2" fiom the back wall to the

centerline of a 6-1/2" dia. hole on the

ceiling. •Note: If drywallis notpresent,adddrywallthicknessto the3-1/2"dimension.

The junction box is located on the top of the

hood, at tim flont right side.

Rotate house wiring as close to tim installation

location as possible, through the ceiling, soffit

or back wall. Wiring should enter at least 4"

above tim bracket on tim right side. 7

Page 8: GE Monogram ® Instructionsinstallation of tiffs product, call the GE Answer Center _>Consumer Information Service at 800.626.2000, 24 hours a day, 7 days a week. If you received a

Installation

36" Vent Hood

s4Install

MountingBrackets

Whenever possible, the vent hood should besecured to wall studs.

• XVith the template roped in place, use apuncll to mark all mounting screw locations.

• Drill 1/8" pilot holes at the 6 punchedlocations.

• Remove the template.• Enlarge holes that did not enter studs to

3/8" and tap anchors for wall fasteners intothe holes.- Drive screws into the fasteners to allow

anchors to expand against the wallmaterial. Remove the screws for finalinstallation.

• Secure the mounting brackets to the wallstuds with wood screws provided.- For hollow walls, secure the mounting

brackets through the anchors.

1Note:Screws "A" and "B" are pre-assembledonto the brackets.Do not remove these screws.

Installthe Hood

Place the hood on the brackets and slide left to

right to align with rectangular slots at the top.

• Adjust the installation height by tightening

or loosening the screws "A" at the bottomof the brackets.

• Align the hood lower mounting holes with

pilot holes in the wall.

• Using two large fiat washers (supplied),

install wood screws or wall fastener screws,

loosely, into lower mounting holes. Do not

tighten.

• I,evel the hood by tightening or looseningthe screws "A" located on the bottom

mounting brackets.

• Tighten the lower mounting screws.

• Tighten screws "B" located at the top of the

mounting bracket against the hood to clamp

the position. Do not overtighten screws.

Screws"B"ToSecureHood

ToWall/--...

--Leveland

HeightAdjustmentScrews"A"

Lower

MountingScrews

Page 9: GE Monogram ® Instructionsinstallation of tiffs product, call the GE Answer Center _>Consumer Information Service at 800.626.2000, 24 hours a day, 7 days a week. If you received a

Installation

36" Vent Hood

Install Duct

Bracket

(jbr vertical exhaust)

Install the 2 small screws into tile sides of

tile duct bracket. Remove tile screws. This

will insure ease of final installation.

Temporarily install a piece of 6" duct cut to

length between tile hood oudet and tile

ductwork at tile ceiling.

Position tile upper duct bracket behind tile

duct and against tile wall and ceiling.Use a level to check that duct is vertical and

duct bracket is centered.

Mark tile 4 screw locations of tile bracket.

Remove tile bracket and temporary ductsection.

Drill 1/8" pilot holes ill marked bracketlocation.

If pilot holes do not enter studs, enlarge tileholes 3/8" and install wall fastener anchors.Drive screws into tile

fasteners to allow anchors

to expand against tile wallmaterial. Remove tile screws. ,_"Secure tile bracket to tile

ceiling and wall with woodscrews and/or wall fastener

screws.

\

DuctWork

Install Duct

Bracket

(jbrho_4zo'ntalexhaust)

Tile upper duct bracket should be installed againsttile ceiling. This bracket will hold tile decorativeduct cover ill place at tile top.• Install tile 2 small screws into tile sides of tile duct

bracket. Remove the screws. This will insure easeof final installation.

• Position tile bracket against tile wall and ceiling.Center tile bracket using marked centerline oftile hood.

• Use a pencil to mark tile bracket location alongits outside edges.

• Temporarily place the decorative duct cover ontop of tile hood and extend tile inner portion tomeet tile ceiling.

• Tile duct cover should be level and align withmarks for bracket.

• Remove tile duct coveL

• Place bracket against marked location and marktile 4 screw locations.

• Drill 1/8" pilot holes ill marked location.• If pilot holes do not enter studs, enlarge tile

holes 3/8" and install wall fastener anchors.Drive screws into tile fasteners to allow anchors

to expand against tile wall material. Removetile screws.

• Secure tile bracket to tile ceiling and wall withwood screws and/or wall fastener screws.

I

I

t/ I \I 1

\ I !

Page 10: GE Monogram ® Instructionsinstallation of tiffs product, call the GE Answer Center _>Consumer Information Service at 800.626.2000, 24 hours a day, 7 days a week. If you received a

Installation

36" Vent Hood

ConnectDuctwork

Do not use sheet metal

screws at hood flange

connection. Doing so will prevent proper

damper operation. Seal connection with

rope only.

Install ductwork, making connections indirection of airflow as illustrated.

Secure joints in ductwork with sheeunemlscrews.

Wrap all duct joints with duct rope for

airtight seal.

Duct TapeOver Seam

and Screw

Air Flow

Screw

Step 8

ConnectElectrical

Verify that power is turned off at the source.

If house wiring is not 2-wire witha ground wire, a ground must beprovided by the insmlleLWhen house wiring is aluminum,be sure to use U.I,. approvedanti-oxidant compound andaluminum-to-copper connectors.

• Insert house wiring through suain reliefand tighten.

• Connect white leads to branch circuitwhite lead.

• Connect black leads to branch circuitblack lead.

• Connect green/yellow leads to branchcircuit green or bare ground lead.

• Secure all connections with wire ntlts oileach electrical connectoL

• Push wires into junction box and replacecoveL Be sure wires are not pinched.

Step 9InstallDecorativeDuct Coverand

UtilityBars

1o

Mounting Screws

/ Notches

Place the decorative duct cover on top ofthe hood.

• Insert the lower portion of the duct coverinto the impression on the top of the hood.

• Extend the inner duct upwards to meet theceiling and bracket.

• Secure the duct cover to the bracket with

the 2 small Phillips screws provided.• Install the side utility bars as shown with

screws provided.

Install Optional ZXl OSY Duct Cover• Separate the supplied duct cover into

pieces. Discard the upper (or inner)section.

• Insert the new ZX10SY duct cover into

the original lower section. Be sure that

the new longer section is inside the shorter

original section. The notches will be at the

bottom and the screw holes at the top asillustrated.

• Follow the same procedures shown aboveto install the new duct cover.

Page 11: GE Monogram ® Instructionsinstallation of tiffs product, call the GE Answer Center _>Consumer Information Service at 800.626.2000, 24 hours a day, 7 days a week. If you received a

Installation

36" Vent Hood

elOInstall Filters

Remove protective film on filters.

Tip the filter into the lower slots at the

rear of the opening, lift the filter and pullthe knob forward until the filter rests on

the slots.

• To remove the filters, grasp the knob andpush the filter towards the rear and tiltdownwards.

e llFinalizeInstallation

• Remove protective film covering the controlpanel on the flont face of the hood and anyremaining packaging materials.

• Refer to the Owner's Manual for

operating instructions.

11

Page 12: GE Monogram ® Instructionsinstallation of tiffs product, call the GE Answer Center _>Consumer Information Service at 800.626.2000, 24 hours a day, 7 days a week. If you received a

Monogram:GEConsumer& IndustrialGEAppliancesGeneralElectricCompanyLouisville,KY40225

monogram.corn

©2007GECompany

Note: \,_ hile perfl_rming installations described in this

book, satety glasses or goggles should be _orn.

For ,\hn_ogram local service i_ 3our area, call1.800.444. 1845.

NOTE: Product improvement is a contimdng endea\_r at General Electric.

There[k_re. materials, appearance and specit3cations are subject to change

without notice.

Pub. No. 49-899{)-9

04/07,JR

Printed in Italy