Spectra Series™ LowAmp Circuit Breaker Busway Plugs
Features and Benefits• Rating Plug—simplifies factory floor and equipment
changeovers because plug has trip/amp interchangeability.• True Digital rms Sensing—more accurate and reliable trip
interruption.• High Interrupting Rating—satisfies high 1C requirements up
to100kAIC@480V.
Low-Tier FramesFrameType/
1C Rating
SEDA
480 V = 14600V =14
SEHA
480 V = 25600 V= 18
SFHA
240 V = 65480 V = 25600V = 18
(A)
152030
405060
708090
100
110125150
152030
405060
708090
100
110125150
7090
100110125150175200225250
3-Wire
CatalogNumber
SL31SEDGSL32SEDGSL33SEDG
SL34SEDGSL35SEDGSL36SEDG
SL37SEDGSL38SEDGSL39SEDGSL310SEDG
SL311SEDGSL312SEDGSL315SEDG
SL31SEHGSL32SEHGSL33SEHG
SL34SEHGSL35SEHGSL36SEHG
SL37SEHGSL38SEHGSL39SEHGSL310SEHG
SL311SEHGSL312SEHGSL315SEHG
SL37SFHGSL39SFHGSL310SFHGSL311SFHGSL312SFHGSL315SFHGSL317SFHGSL320SFHGSL322SFHGSL325SFHG
List Price,GO-112M
$ 695.00695.00695.00
695.00695.00695.00
765.00765.00765.00765.00
1787.001787.001787.00
881.00881.00881.00
881.00881.00881.00
1001.001001.001001.001001.00
1997.001997.001997.00
1997.001997.001997.001997.001997.001997.001997.001997.001997.001997.00
4-Wire
CatalogNumber
SL41SEDGSL42SEDGSL43SEDG
SL44SEDGSL45SEDGSL46SEDG
SL47SEDGSL48SEDGSL49SEDGSL410SEDG
SL411SEDGSL412SEDGSL415SEDG
SL41SEHGSL42SEHGSL43SEHG
SL44SEHGSL45SEHGSL46SEHG
SL47SEHGSL48SEHGSL49SEHGSL410SEHG
SL411SEHGSL412SEHGSL415SEHG
SL47SFHGSL49SFHGSL410SFHGSL411SFHGSL412SFHGSL415SFHGSL417SFHGSL420SFHGSL422SFHGSL425SFHG
List Price,GO-112M
$ 755.00755.00755.00
755.00755.00755.00
826.00826.00826.00826.00
1847.001847.001847.00
941.00941.00941.00
941.00941.00941.00
1013.001013.001013.001013.00
2051.002051.002051.00
2051.002051.002051.002051.002051.002051.002051.002051.002051.002051.00
Circuit Breaker PlugsStandard Frames
FrameType/
1C Rating
TEB240V =10
TED4240 V = 18480 V = 14
TED6240 V= 18480 V= 14600 V= 14
Trip
152030405060
70100
152030405060
70100
152030
405060
70100
3-Wire
CatalogNumber
SL31 EBGSL32EBGSL33EBGSL34EBGSL35EBGSL36EBG
SL37EBGSL310EBG
SL31ED4GSL32ED4GSL33ED4GSL34ED4GSL35ED4GSL36ED4G
SL37ED4GSL310ED4G
SL31ED6GSL32ED6GSL33ED6G
SL34ED6GSL35ED6GSL36ED6G
SL37ED6GSL310ED6G
List Price,GO-112M
$514.00514.00514.00514.00514.00514.00
619.00619.00
640.00640.00640.00640.00640.00640.00
712.00712.00
706.00706.00706.00
706.00706.00706.00
778.00778.00
4-Wire
CatalogNumber
SL41EBGSL42EBGSL43EBGSL44EBGSL45EBGSL46EBG
SL47EBGSL410EBG
SL41ED4GSL42ED4GSL43ED4GSL44ED4GSL45ED4GSL46ED4G
SL47ED4GSL410ED4G
SL41ED6GSL42ED6GSL43ED6G
SL44ED6GSL45ED6GSL46ED6G
SL47ED6GSL410ED6G
List Price,GO-112M
$574.00574.00574.00574.00574.00574.00
672.00672.00
706.00706.00706.00706.00706.00706.00
764.00764.00
757.00757.00757.00
757.00757.00757.00
836.00836.00
UL Listed and CSA Certified—for heat rise, short-circuit, andground fault.Interlocks and Safety Features—door interlock, pluginterlock, ground contact before stab contact, and plug assistfor mechanical installation.
Mid-Tier FramesFrameType/
1C Rating
SELO,
480 V = 65600 V = 25
SFU\
240 V = 100480 V = 65600 V = 25
Trip
152030
405060
708090
100
110125150
7090
100110125150175200225250
3-Wire
CatalogNumber
SL31SELGSL32SELGSL33SELG
SL34SELGSL35SELGSL36SELG
SL37SELGSL38SELGSL39SELGSL310SELG
SL311SELGSL312SELGSL315SELG
SL37SFLGSL39SFLGSL310SFLGSL311SFLGSL312SFLGSL315SFLGSL317SFLGSL320SFLGSL322SFLGSL325SFLG
List Price,GO-112M
$1343.001343.001343.00
1343.001343.001343.00
1583.001583.001583.001583.00
3347.003347.003347.00
3586.003586.003586.003586.003586.003586.003586.003586.003586.003586.00
4-Wire
CatalogNumber
SL41SELGSL42SELGSL43SELG
SL44SELGSL45SELGSL46SELG
SL47SELGSL48SELGSL49SELGSL410SELG
SL411SELGSL412SELGSL415SELG
SL47SFLGSL49SFLGSL410SFLGSL411SFLGSL412SFLGSL415SFLGSL417SFLGSL420SFLGSL422SFLGSL425SFLG
List Price,GO-112M
$1463.001463.001463.00
1463.001463.001463.00
1703.001703.001703.001703.00
3467.003467.003467.00
3714.003714.003714.003714.003714.003714.003714.003714.003714.003714.00
Without Rating PlugFrameType/
1C Rating
SEDA
SEHA
SFHA
SEU\
SFL^
Trip
15-3040-6070-100
110-150
15-3040-6070-100
110-150
70-250
15-3040-6070-100
110-150
70-250
3-Wire
CatalogNumber
SL301SEDGSL302SEDGSL303SEDGSL304SEDG
SL301SEHGSL302SEHGSL303SEHGSL304SEHG
SL300SFHG
SL301SELGSL302SELGSL303SELGSL304SELG
SL300SFLG
List Price,GO-112M
$ 635.00635.00706.00
1727.00
821.00821.00878.00
1937.00
1937.00
1343.001343.001583.003347.00
3526.00
4-Wire
CatalogNumber
SL401SEDGSL402SEDGSL403SEDGSL404SEDG
SL401SEHGSL402SEHGSL403SEHGSL404SEHG
SL400SFHG
SL401SELGSL402SELGSL403SELGSL404SELG
SL400SFLG
List Price,GO-112M
$ 695.00695.00766.00
1787.00
1121.001121.001218.001991.00
1991.00
1463.001463.001703.003718.00
3658.00
Breakers must be factory-installed.
Enclosure Only(Order circuit breaker from Section 4)
FrameType
E©F©
Trip
100 A max.225 A max.
3-Phase, 3-Wire
CatalogNumber
SL3000EGSL3225FG
List Price,GO-112M
$ 252.00552.00
3-Phase, 4-Wire
CatalogNumber
SL4000EGSL4225FG
List Price,GO-112M
$ 306.00636.00
® Not for Spectra breakers. E and F frame enclosures for standardmolded case circuit breakers only.
16-36 1999 Issue Prices and data subject to change without notice
GE Busway
Busway—Plug Short-Circuit RatingsFusible Switch Busway PlugsFusible switches in all busway fittings (plugs, power takeoffs, andreducers) have the following short-circuit ratings when used withthe fuses shown. To qualify for R fuse rating, switches must haveR fuse clips which reject other type fuses. The interrupting ratingof the fuse must equal or exceed the short-circuit rating of theswitch. If it is lower than the short-circuit rating of the switch, thenthe combination has the rating of the fuse.
SwitchType
QMR
SwitchAmpereRating
30to1200
Fuse
UL Class
HK5K1
JRL
Description
One TimeHigh InterruptingHigh Interrupting
Current LimitingCurrent LimitingCurrent Limiting
Interrupting RatingAmperes rms Symmetrical
240 and 480 Volts
10,000
200,000
Circuit Breaker Busway Plugs STM
Construction
StandardFrames
Hi-Break®Frames
FuselessCurrentLimiting
HighInterrupting
Tri-Break®Interrupting
Spectra®FrameType
—
SED
SED
SFH
SFH
SGH4
SGH4
SGH6
SGH6
SKH
SKH
SEH
SFH
SGH4
SGH6
SGH6
SGH6
SKH
SKH
SEP
SFP
SGP4
SGP6
SEL
SFL
SGL4
SGL6
SGL6
SKL
SKL
—:
—
TripRange(Amps)
_
15-150
15-150
70-250
70-250
125-400
125-400
250-600
250-600
300-800
300-800
15-150
70-250
125-400
250-600
250-600
250-600
300-800
300-800
15-150
70-250
125-400
250-600
15-150
70-250
125-400
250-600
250-600
300-800
300-800
—
—
OldFrameType
TEB
TED4
TED6
TFJ
TFK
TJJ
TJK4
'TJK6
TJ4V
TKM8
TK4V
THED
THFK
THJK4
THJK6
THJ4V
TJH
THKM8
TKH
THLC1 ®
THLC2®
THLC4®
_
TEL®
TFL®
TLB4®
TJL4V
TJL
TKL4V
TKL
TB1
TB4
TB6
TBS
TripRange(Amps)
15-100
15-100
15-100
70-225
70-225
125-400
125-400
250-600
150-600
300-800
800
15-100
70-225
125-400
400-600
150-600
150-600
300-800
300-800
15-100
125-225
225-400
—
15-100
125-225
250-400
1 50-600
150-600
400-800
800
15-100
125-400
300-600
600-800
Spectra Frame®1C Ratings
240V
—
18
18
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
65
200
200
200
200
100
100
100
100
100
100
100
_
—
480V
—
14
14
25
25
35
35
35
35
50
50
25
25
35
35
35
35
60
50
100
100
100
100
65
65
65
65
65
65
65
—
600V
—
14
14
18
18
25
25
25
25
25
25
18
18
25
25
25
25
25
25
25
25
65
65
25
25
65
65
65
65
65
-
Old Frame1C Ratings
240V
10
18
18
25
25
42
42
42
42
42
42
65
65
65
65
65
65
65
65
200
200
200
—
100
100
85
100
100
100
100
200
200
200
200
480V
—
14
14
22
22
30
30
30
30
30
30
25
25
35
35
35
35
35
50
150
150
150
—
65
65
50
65
65
65
65
200
200
200
200
600V
—
_
14
18
18
22
22
22
22
22
22
18
18
25
25
25
25
25
25
_
_
_
25
25
_
30
30
42
42
200
200
200
200
© Spectra RMS™ Circuit Breakers UL listed for .Spectra Series™ Busway only.® UL listed interrupting ratings in thousand amperes rms symmetrical ac volts.® Discontinued; replaced by Spectra Frame Type.
Spectra RMS1
Circuit BreakerMaximum 1C Ratings(rms sym. kA)
FrameType
SEDSEHSELSEPSFHSFLSFPSGH4SGL4SGP4SGH6SGL6SGP6SKHSKLSKP
240V
1865
100200
65100200
65100200
65100200
65100200
480V
142565
1002565
1003565
1003565
1005065
100
600V
14182525182525256565256565254265
16-4 1999 Issue Data subject to change without notice
GE Busway
Features/BenefitsEasy Install:• New Joint-Guard™ Protection System—dynamically
indicates proper torque through color! Easy install andmaintenance!
• Lighter Weight—means it installs faster than other buswaysand beats wire and conduit for total installed cost.
• Single Drop-Rod Hanger—is furnished with straight lengthsfor easy, fast installation.
• Field-Adjustable Isolation Joint—(± W per joint) provideson-site flexibility.
• Adjustable Straight Length—can eliminate the need for fieldcheck pieces! (±6" from nominal 54").
Performance/Protection/Maintenance:• Exclusive BlueCoat™ Epoxy Insulation—(Class B, UL
130°C) provides the industry's best protection (50 years).• Earth-Bond™ Integrated Grounding System—provides a
lower resistance ground path than internal ground bars.• IP4X Plug Outlet—GE's exclusive plug outlet provides the
industry's highest protection. It's "dead front" is fingerproof andscrewdriver-proof (Also meets IP2X and IP3X.)
• Belleville Spring Washer—the industry's best, retains over90% of original contact pressure, offering a maintenance-freejoint if torqued properly.
Spectra Series LowArnp Busway Catalog Numbering System
Spectra Series™ LowAmp BuswayApplication and Pricing
Available RatingsAmperes: 225 to 800 amperesVoltage: 600 Volts or lessBusing: Aluminum or CopperSystems: 3-phase, 3-wire and 3-phase, 4-wire (full neutral)Enclosures: Indoor, drip-proof, (totally enclosed)
Spectra Series LowAmp Busway Pricing• Catalog number pricingUse the catalog numbers from tables, or parametric catalognumber generation, on pages 16-28 through 16-33 to pricebusway components individually. One standard flatwise clevis-type hanger is provided with every straight length. Optionalhangers are available and ordered separately.
Product
Type
Service
Ground
Conductor
Description
Spectra Series LowAmp
FeederPlug-In >
3PH, 3W3PH.4W 100% Neutral
Integrated HousingInternal Bus '
CopperAluminum
Configurations
Straight LengthElbow-LettElbow-RightElbow-UpElbow-DownCenter Cable Tap Box-UpCenter Cable Tap Box-DownEnd Cable Tap Box-UpEnd Cable Tap Box-DownEnd BoxFlanged EndFlanged End w/LugsAdjustable Straight-LengthExpansion Length-UpExpansion Length-DownTotal Phase TranspositionTee-RightTee-LeftTee-UpTee-DownOff Set-UpOff Set-DownOff Set-RightOff Set-Left
Code
SLELEREUEDCTCBTTTBEBFEFLASXUXDTFTRTLTUTDOUODOROL
Code
L
FP
34
HG
CA
L F 3 h
Configurations Code
Busway AdaSpectra BusArmor-Clad'Armor-CladBusway StuSpectra/AV-AKDS/PoweMCC 8000 LPanelboards
pterSB
Style 3 Blot End BEStyle 3 Slot End SE)s (600-800) 8S
Break AKne MC
PA
1 C 02 S
Amps ' Code
225 02400 04600 06800 08
2 B1
Type
IndoorTransverse Barrier 3
Code
BlankB
Type
Feeder
Plug-In
Fittings
Off Sets:6"12"18"
Feet
235
10
46
10
NA
Code
02030510
040610
ST
061218
© Available w/copper bus bars only.® Requires drawing for layout configuration.© Item available in feeder construction only. (Use with fire barrier and wall/floor flange for 3-hour fire rating).® Straight lengths only.
Prices and data subject to change without notice 1999 Issue 16-29
GE Busway
Spectra Series™ LowAmp BuswayDimensions
TOP EDGEOFBUSWAY
Figure ADoor hinges at left end. All dimensionsare shown over largest part of plug.
Figure BDoor hinges at top. All dimensionsare shown over largest part of plug.
Fittings—Elbows, Tees, and OffsetsSpectra Series™ LowAmp busway has acomplete family of standard catalog fittingsto meet virtually all layout requirementsusing the compact minimum sizes shown.Nomenclature for completely defining theturn is accomplished by looking into thejoint end with phase 0 side facing down onthe busway. Using this guideline, a rightelbow turns right, an up elbow turns up, etc.Every piece of busway is labeled to maintainproper phasing. Unless otherwise noted, allturn dimensions are defined from thecenterline of the joint end to the centerlineof the busway. Figures show dimensionsfor elbow, tee, and offset fittings.
Molded-Case Circuit Breakers(Outer Dimensions)
Type
Standardand
Hi-Break*
Low- andMid-Tier
Frame
TEBTED, THEDTED, THED
SED, SEH, SELSFH, SFL
TripRange
15-10015-100
110-150
15-15070-225
VoltageRating
240600600
480600
Dimension(Inches)
W
11
1111
L
13
1321'/4
D
8
89
Fig.No.
A
A
Fusible Switches(Outer Dimensions)
Type
QMR
VoltageRating
240and600
Amps
30
60
100
200
400
Weight(Ibs.)
24
25
28
46
135
Dimensions (Inches)
W
11.25
16.00
20.50
Length
StandardGutter
13.00
18.75
ExtendedGutter
18.63
NA
24.50
NA
D
8.75
18.75
Fig.
A
B
0SIDC UJ.JTDOWN
Up Elbow Shown (Down Elbow Reversed) Down Offset Shown (Up Offset Reversed)
Down Tee Shown (Up Tee Reversed)
,-̂
Right Offset Shown (Left Offset Reversed)
16-40Right Tee Shown (Left Tee Reversed)
1999 Issue
Right Elbow Shown (Left Elbow Reversed)
Data subject to change without notice