Specifications in this guide:
• 2-way piloted diaphragm valves• Available in normally closed and normally open operation modes• 1 to 250 psi• Cv to 29• Orificesto1-1/2”• Brass or stainless steel body• Buna,EPR,NORYL,Plastic,Teflon,orVitonseals• 3/8”to2”NPTports
• S21Series3/8”NPT,BrassBody,NormallyClosed• S21Series3/8”NPT,Type316SSBody,NormallyClosed• S21Series3/8”NPT,BrassBody,NormallyClosed,HighPerformance• H21Series3/8”NPT,BrassBody,NormallyClosed,HighPressure• S21Series3/8”NPT,BrassBody,NormallyClosed• S21Series3/8”NPT,Type316SSBody,NormallyOpen• S21Series3/8”NPT,BrassBody,NormallyOpen,HighPerformance• S21Series1/2”NPT,BrassBody,NormallyClosed• S21Series1/2”NPT,Type316SSBody,NormallyClosed• S21Series1/2”NPT,BrassBody,NormallyClosed,HighPerformance• H21Series1/2”NPT,BrassBody,NormallyClosed,HighPressure• S21Series1/2”NPT,BrassBody,NormallyOpen• S21Series1/2”NPT,Type316SSBody,NormallyOpen• S21Series1/2”NPT,BrassBody,NormallyOpen,HighPerformance• S21Series3/4”NPT,BrassBody,NormallyClosed• S21Series3/4”NPT,Type316SSBody,NormallyClosed• S21Series3/4”NPT,BrassBody,NormallyClosed,HighPerformance• H21Series3/4”NPT,BrassBody,NormallyClosed,HighPressure• S21Series3/4”NPT,BrassBody,NormallyOpen• S21Series3/4”NPT,Type316SSBody,NormallyOpen• S21Series3/4”NPT,BrassBody,NormallyOpen,HighPerformance• S21Series1”NPT,BrassBody,NormallyClosed• S21Series1”NPT,Type316SSBody,NormallyClosed• S21Series1”NPT,BrassBody,NormallyClosed,HighPerformance• S21Series1”NPT,Type316SSBody,NormallyClosed,HighPerformance• S21Series1”NPT,BrassBody,NormallyOpen• S21Series1”NPT,Type316SSBody,NormallyOpen
MountainControlsisproudtoofferqualitysolenoidvalvesfromGCvalves.TheS21Seriesfeaturesthefollowing:
![Page 2: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/2.jpg)
Page 2
• S21Series1”NPT,Type316SSBody,NormallyOpen,HighPerformance• S21Series1-1/4”NPT,BrassBody,NormallyClosed• S21Series1-1/4”NPT,Type316SSBody,NormallyClosed• S21Series1-1/4”NPT,BrassBody,NormallyClosed,HighPerformance• S21Series1-1/4”NPT,Type316SSBody,NormallyClosed,HighPerformance• S21Series1-1/4”NPT,BrassBody,NormallyOpen• S21Series1-1/4”NPT,Type316SSBody,NormallyOpen• S21Series1-1/4”NPT,BrassBody,NormallyOpen,HighPerformance • S21Series1-1/4”NPT,Type316SSBody,NormallyOpen,HighPerformance• S21Series1-1/2”NPT,BrassBody,NormallyClosed• S21Series1-1/2”NPT,Type316SSBody,NormallyClosed• S21Series1-1/2”NPT,BrassBody,NormallyClosed,HighPerformance• S21Series1-1/2”NPT,Type316SSBody,NormallyClosed,HighPerformance• S21Series1-1/2”NPT,BrassBody,NormallyOpen• S21Series1-1/2”NPT,Type316SSBody,NormallyOpen• S21Series1-1/2”NPT,BrassBody,NormallyOpen,HighPerformance• S21Series1-1/2”NPT,Type316SSBody,NormallyOpen,HighPerformance• S21Series2”NPT,BrassBody,NormallyClosed• S21Series2”NPT,Type316SSBody,NormallyClosed• S21Series2”NPT,BrassBody,NormallyClosed,HighPerformance• S21Series2”NPT,Type316SSBody,NormallyClosed,HighPerformance• S21Series2”NPT,BrassBody,NormallyOpen• S21Series2”NPT,Type316SSBody,NormallyOpen• S21Series2”NPT,BrassBody,NormallyOpen,HighPerformance• S21Series2”NPT,Type316SSBody,NormallyOpen,HighPerformance
![Page 3: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/3.jpg)
Page 3For ordering information, visit mountaincontrols.com.
S21 Series
Dimensions/Weight
- 3/8" NPT- Brass Body- 2-Way Piloted
Diaphragm- Normally Closed
Materials Seals: Nitrile, Viton®, Ethylene Propylene
Orifice: Pilot Stainless SteelMain Brass Ø 5/8”
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: Any
Approvals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
2.5
* Not available for all variations
![Page 4: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/4.jpg)
Page4For ordering information, visit mountaincontrols.com.
S211 – 3/8" NPT, Brass Body, Normally Closed
5/8 4.3 4 200 150 150 100 — — — — 295 EPR 8 10 S211GF02C5CG4
3/85/8 4.3 4 200 150 150 100 150 100 — — 180 Nitrile 8 10 S211GF02N5CG4
5/8 4.3 4 200 150 150 100 150 100 — — 230 Viton 8 10 S211GF02V5CG4
5/8 4.3 4 — — — — — — 50* 50* 295 EPR 8 10 S211GH02C5CG4
IN °F
Normally Closed
Valve Selection List
P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Brass Body
( )
S 2 1 1 G F 0 2 C 5 C G 4Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
C: EPRN: NitrileV: Viton
5: Brass C: 3/8” NPT G4: 5/8”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
1: NormallyClosed
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 36 36
Holding 13 14
Coil Family
Type Size
AC S3DC S4
* Class H Coil Recommended for Steam and Other High Temperature Applications
![Page 5: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/5.jpg)
Page 5For ordering information, visit mountaincontrols.com.
S21 Series
Dimensions/Weight
- 3/8" NPT- Stainless Steel Body
Type 316- 2-Way Piloted Diaphragm- Normally Closed
Materials Seals: Nitrile, Viton®, Ethylene Propylene
Orifice: Pilot Stainless SteelMain Stainless Steel Ø 5/8”
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: Any
Approvals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
2.5
* Not available for all variations
![Page 6: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/6.jpg)
Page6For ordering information, visit mountaincontrols.com.
S211 – 3/8" NPT, Stainless Steel Body, Type 316,Normally Closed
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 36 36
Holding 13 14
Coil Family
Type Size
AC S3DC S4
S 2 1 1 G F 0 2 E 7 C G 4Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
E: EPRJ: NitrileL: Viton
7: 316 SS C: 3/8” NPT G4: 5/8”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
1: NormallyClosed
5/8 4.3 4 200 150 150 100 — — — — 295 EPR 8 10 S211GF02E7CG4
3/85/8 4.3 4 200 150 150 100 150 100 — — 180 Nitrile 8 10 S211GF02J7CG4
5/8 4.3 4 200 150 150 100 150 100 — — 230 Viton 8 10 S211GF02L7CG4
5/8 4.3 4 — — — — — — 50* 50* 295 EPR 8 10 S211GH02E7CG4
IN °F
Normally Closed
Valve Selection List
P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Stainless Steel BodyType 316
( )
* Class H Coil Recommended for Steam and Other High Temperature Applications
![Page 7: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/7.jpg)
Page 7For ordering information, visit mountaincontrols.com.
S21 Series
Dimensions/Weight
- High Performance- 3/8" NPT- Brass Body- 2-Way Piloted
Diaphragm- Normally ClosedMaterials Seals: Viton®, Teflon®
Orifice: Pilot Stainless SteelMain Stainless Steel Ø 1/2”
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz availableContact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: ± 45º From Vertical
Approvals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
2.5
* Not available for all variations
Body Code 4 Body Code 2
![Page 8: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/8.jpg)
Page8For ordering information, visit mountaincontrols.com.
S211 – High Performance, 3/8" NPT, Brass Body,Normally Closed
S 2 1 1 G F 0 2 K 4 C G 1Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
K: VitonT: Teflon
4: ForgedBrass
2: Brass
C: 3/8” NPT
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
1: NormallyClosed
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 36 36
Holding 13 14
Coil Family
Type Size
All S3
1/2 3.3 1 250 150 250 150 250 150 — — 230 Viton 8 9 S211GF02K4CG1
3/8 1/2 3.3 1 — — — — — — 100*100* 338 Teflon 8 9 S211GH02T4CG1
1/2 3.3 10 — — — — — — 150*150* 366 Teflon 8 9 S211GH02T2CG1
IN °F
Normally Closed
Valve Selection List
P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Brass Body
( )
* Class H Coil Recommended for Steam and Other High Temperature Applications
![Page 9: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/9.jpg)
Page 9For ordering information, visit mountaincontrols.com.
H21 Series
Dimensions/Weight
- High Pressure- 3/8" NPT- Brass Body- 2-Way Piloted
Diaphragm- Normally ClosedMaterials Seals: Viton®, Teflon®
Orifice: Pilot Stainless SteelMain Stainless Steel Ø 1/2”
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz availableContact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: Any
Approvals* Agency: UL Recognized
® Registered Trademark of DuPont Co.
Weight (lbs.)
2.5
* Not available for all variations
![Page 10: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/10.jpg)
Page 10For ordering information, visit mountaincontrols.com.
H211 – High Pressure, 3/8" NPT, Brass Body,Normally Closed
H 2 1 1 G F 0 2 Z 4 C G 1Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
H21 G: Conduit F: Class F 02: 120/60110/50
Z: Viton/Teflon
4: Brass C: 3/8” NPT G1: 1/2”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
1: NormallyClosed
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 46 46
Holding 18 19
Coil Family
Type Size
All S4
3/8 1/2 3.3 10 1400 1400 1400 1400 1400 1400 230 Viton/Teflon 10 10 H211GF02Z4CG1
IN °F
Normally Closed
Valve Selection List
P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Brass Body
( )
![Page 11: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/11.jpg)
Page 11For ordering information, visit mountaincontrols.com.
S21 Series
Dimensions/Weight
- 3/8" NPT- Brass Body- 2-Way Piloted
Diaphragm- Normally Open
Materials Seals: Nitrile, Viton®, Ethylene Propylene
Orifice: Pilot Stainless SteelMain Brass Ø 5/8”
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: Any
Approvals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
2.5
* Not available for all variations
![Page 12: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/12.jpg)
Page 12For ordering information, visit mountaincontrols.com.
S212 – 3/8" NPT, Brass Body, Normally Open
5/8 3.3 3 200 140 200 125 — — — — 295 EPR 11 10 S212GF02C5CG4
3/85/8 3.3 3 200 140 200 125 200 125 — — 180 Nitrile 11 10 S212GF02N5CG4
5/8 3.3 3 200 140 200 125 200 125 — — 230 Viton 11 10 S212GF02V5CG4
5/8 3.3 3 — — — — — — 50* 50* 295 EPR 11 10 S212GH02C5CG4
IN °F
Normally Open
Valve Selection List
P P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Brass Body
( )
S 2 1 2 G F 0 2 C 5 C G 4Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
C: EPRN: NitrileV: Viton
5: Brass C: 3/8” NPT G4: 5/8”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
2: NormallyOpen
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 46 46
Holding 22 25
Coil Family
Type Size
ALL S4
* Class H Coil Recommended for Steam and Other High Temperature Applications
![Page 13: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/13.jpg)
Page 13For ordering information, visit mountaincontrols.com.
S21 Series
Dimensions/Weight
- 3/8" NPT- Stainless Steel Body
Type 316- 2-Way Piloted Diaphragm- Normally Open
Materials Seals: Nitrile, Viton®, Ethylene Propylene
Orifice: Pilot Stainless SteelMain Stainless Steel Ø 5/8”
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: Any
Approvals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
2.5
* Not available for all variations
![Page 14: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/14.jpg)
Page14For ordering information, visit mountaincontrols.com.
S212 – 3/8" NPT, Stainless Steel Body, Type 316,Normally Open
5/8 3.3 3 200 140 200 125 — — — — 295 EPR 11 10 S212GF02E7CG4
3/85/8 3.3 3 250 140 200 125 200 125 — — 180 Nitrile 11 10 S212GF02J7CG4
5/8 3.3 3 200 140 200 125 200 125 — — 230 Viton 11 10 S212GF02L7CG4
5/8 3.3 3 — — — — — — 50* 50* 295 EPR 11 10 S212GH02E7CG4
IN °F
Normally Open
Valve Selection List
P P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Stainless Steel BodyType 316
( )
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 46 46
Holding 22 25
Coil Family
Type Size
ALL S4
S 2 1 2 G F 0 2 E 7 C G 4Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
E: EPRJ: NitrileL: Viton
7: 316 SS C: 3/8” NPT G4: 5/8”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
2: NormallyOpen
* Class H Coil Recommended for Steam and Other High Temperature Applications
![Page 15: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/15.jpg)
Page 15For ordering information, visit mountaincontrols.com.
S21 Series
Dimensions/Weight
- High Performance- 3/8" NPT- Brass Body- 2-Way Piloted
Diaphragm- Normally OpenMaterials Seals: Viton®, Teflon®
Orifice: Pilot Stainless SteelMain Stainless Steel Ø 1/2”
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz availableContact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: Any
Approvals* Agency: UL Recognized
® Registered Trademark of DuPont Co.
Weight (lbs.)
2.5
* Not available for all variations
Body Code 4 Body Code 2
![Page 16: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/16.jpg)
Page16For ordering information, visit mountaincontrols.com.
S212 – High Performance, 3/8" NPT, Brass Body,Normally Open
S 2 1 2 G F 0 2 K 4 C G 1Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
K: VitonT: Teflon
4: ForgedBrass
2: Brass
C: 3/8” NPT G1: 1/2”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
2: NormallyOpen
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 36 36
Holding 18 19
Coil Family
Type Size
All S3
1/2 3.3 1 150 140 150 140 150 140 — — 230 Viton 8 9 S212GF02K4CG1
3/8 1/2 3.3 1 — — — — — — 100*100* 338 Teflon 8 9 S212GH02T4CG1
1/2 3.3 10 — — — — — — 150*140* 366 Teflon 8 9 S212GH02T2CG1
IN °F
Normally Open
Valve Selection List
P P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Brass Body
( )
* Class H Coil Recommended for Steam and Other High Temperature Applications
![Page 17: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/17.jpg)
Page 17For ordering information, visit mountaincontrols.com.
S21 Series
Dimensions/Weight
- 1/2" NPT- Brass Body- 2-Way Piloted
Diaphragm- Normally Closed
Materials Seals: Nitrile, Viton®, Ethylene Propylene
Orifice: Pilot Stainless SteelMain Brass Ø 5/8”
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: Any
Approvals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
2.5
* Not available for all variations
![Page 18: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/18.jpg)
Page18For ordering information, visit mountaincontrols.com.
S211 – 1/2" NPT, Brass Body, Normally Closed
S 2 1 1 G F 0 2 C 5 D G 4Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
C: EPRN: NitrileV: Viton
5: Brass D: 1/2” NPT G4: 5/8”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
1: NormallyClosed
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 36 36
Holding 13 14
Coil Family
Type Size
AC S3DC S4
5/8 4.3 4 200 150 150 100 — — — — 295 EPR 8 10 S211GF02C5DG4
1/25/8 4.3 4 200 150 150 100 150 100 — — 180 Nitrile 8 10 S211GF02N5DG4
5/8 4.3 4 200 150 150 100 150 100 — — 230 Viton 8 10 S211GF02V5DG4
5/8 4.3 4 — — — — — — 50* 50* 295 EPR 8 10 S211GH02C5DG4
IN °F
Normally Closed
Valve Selection List
P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Brass Body
( )
* Class H Coil Recommended for Steam and Other High Temperature Applications
![Page 19: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/19.jpg)
Page 19For ordering information, visit mountaincontrols.com.
Dimensions/Weight
- 1/2" NPT- Stainless Steel Body
Type 316- 2-Way Piloted Diaphragm- Normally Closed
Materials Seals: Nitrile , Viton®, Ethylene Propylene
Orifice: Pilot Stainless SteelMain Stainless Steel Ø 5/8”
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: Any
Approvals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
2.5
S21 Series
* Not available for all variations
![Page 20: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/20.jpg)
Page 20For ordering information, visit mountaincontrols.com.
S211 – 1/2" NPT, Stainless Steel Body, Type 316,Normally Closed
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 36 36
Holding 13 14
Coil Family
Type Size
AC S3DC S4
S 2 1 1 G F 0 2 E 7 D G 4Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
E: EPRJ: NitrileL: Viton
7: 316 SS D: 1/2” NPT G4: 5/8”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
1: NormallyClosed
5/8 4.3 4 200 150 150 100 — — — — 295 EPR 8 10 S211GF02E7DG4
1/25/8 4.3 4 200 150 150 100 150 100 — — 180 Nitrile 8 10 S211GF02J7DG4
5/8 4.3 4 200 150 150 100 150 100 — — 230 Viton 8 10 S211GF02L7DG4
5/8 4.3 4 — — — — — — 50* 50* 295 EPR 8 10 S211GH02E7DG4
IN °F
Normally Closed
Valve Selection List
P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Stainless Steel BodyType 316
( )
* Class H Coil Recommended for Steam and Other High Temperature Applications
![Page 21: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/21.jpg)
Page 21For ordering information, visit mountaincontrols.com.
S21 Series
Dimensions/Weight
- High Performance- 1/2" NPT- Brass Body- 2-Way Piloted
Diaphragm- Normally ClosedMaterials Seals: Viton®, Teflon®
Orifice: Pilot Stainless SteelMain Stainless Steel Ø 1/2”
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz availableContact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: ± 45º From Vertical
Approvals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
2.5
* Not available for all variations
Body Code 4 Body Code 2
![Page 22: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/22.jpg)
Page 22For ordering information, visit mountaincontrols.com.
S 2 1 1 G F 0 2 K 4 D G 1Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
K: VitonT: Teflon
4: ForgedBrass
2: Brass
D: 1/2” NPT G1: 1/2”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
1: NormallyClosed
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 36 36
Holding 13 14
Coil Family
Type Size
All S3
1/2 3.3 1 250 150 250 150 250 150 — — 230 Viton 8 9 S211GF02K4DG1
1/2 1/2 3.3 1 — — — — — — 100*100* 338 Teflon 8 9 S211GH02T4DG1
1/2 3.6 10 — — — — — — 150*150* 366 Teflon 8 9 S211GH02T2DG1
IN °F
Normally Closed
Valve Selection List
P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Brass Body
( )
* Class H Coil Recommended for Steam and Other High Temperature Applications
S211 – High Performance, 1/2" NPT, Brass Body,Normally Closed
![Page 23: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/23.jpg)
Page 23For ordering information, visit mountaincontrols.com.
H21 Series
Dimensions/Weight
- High Pressure- 1/2" NPT- Brass Body- 2-Way Piloted
Diaphragm- Normally ClosedMaterials Seals: Viton®, Teflon®
Orifice: Pilot Stainless SteelMain Stainless Steel Ø 1/2”
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz availableContact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: Any
Approvals* Agency: UL Recognized
® Registered Trademark of DuPont Co.
Weight (lbs.)
2.5
* Not available for all variations
![Page 24: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/24.jpg)
Page24For ordering information, visit mountaincontrols.com.
H211 – High Pressure, 1/2" NPT, Brass Body,Normally Closed
H 2 1 1 G F 0 2 Z 4 D G 1Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
H21 G: Conduit F: Class F 02: 120/60110/50
Z: Viton/Teflon
4: Brass D: 1/2” NPT G1: 1/2”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
1: NormallyClosed
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 46 46
Holding 18 19
Coil Family
Type Size
All S4
1/2 1/2 3.3 10 1400 1400 1400 1400 1400 1400 230 Viton/Teflon 10 10 H211GF02Z4DG1
IN °F
Normally Closed
Valve Selection List
P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Brass Body
( )AC DC AC DC AC DC
Air/Gas Water Light Oil
![Page 25: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/25.jpg)
Page 25For ordering information, visit mountaincontrols.com.
S21 Series
Dimensions/Weight
- 1/2" NPT- Brass Body- 2-Way Piloted
Diaphragm- Normally Open
Materials Seals: Nitrile, Viton®, Ethylene Propylene
Orifice: Pilot Stainless SteelMain Brass Ø 5/8”
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: Any
Approvals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
2.5
* Not available for all variations
![Page 26: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/26.jpg)
Page26For ordering information, visit mountaincontrols.com.
S212 – 1/2" NPT, Brass Body, Normally Open
S 2 1 2 G F 0 2 C 5 D G 4Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
C: EPRN: NitrileV: Viton
5: Brass D: 1/2” NPT G4: 5/8”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
2: NormallyOpen
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 46 46
Holding 22 25
Coil Family
Type Size
ALL S4
5/8 4.3 3 200 140 200 125 — — — — 295 EPR 11 10 S212GF02C5DG4
1/25/8 4.3 3 200 140 200 125 200 125 — — 180 Nitrile 11 10 S212GF02N5DG4
5/8 4.3 3 200 140 200 125 200 125 — — 230 Viton 11 10 S212GF02V5DG4
5/8 4.3 3 — — — — — — 50* 50* 295 EPR 11 10 S212GH02C5DG4
IN °F
Normally Open
Valve Selection List
P P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Brass Body
( )
* Class H Coil Recommended for Steam and Other High Temperature Applications
![Page 27: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/27.jpg)
Page 27For ordering information, visit mountaincontrols.com.
S21 Series
Dimensions/Weight
- 1/2" NPT- Stainless Steel Body
Type 316- 2-Way Piloted Diaphragm- Normally Open
Materials Seals: Nitrile, Viton®, Ethylene Propylene
Orifice: Pilot Stainless SteelMain Stainless Steel Ø 5/8”
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: Any
Approvals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
2.5
* Not available for all variations
![Page 28: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/28.jpg)
Page28For ordering information, visit mountaincontrols.com.
S212 – 1/2" NPT, Stainless Steel Body, Type 316,Normally Open
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 46 46
Holding 22 25
Coil Family
Type Size
ALL S4
S 2 1 2 G F 0 2 E 7 D G 4Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
E: EPRJ: NitrileL: Viton
7: 316 SS D: 1/2” NPT G4: 5/8”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
2: NormallyOpen
5/8 4.3 3 200 140 200 125 — — — — 295 EPR 11 10 S212GF02E7DG4
1/25/8 4.3 3 200 140 200 125 200 125 — — 180 Nitrile 11 10 S212GF02J7DG4
5/8 4.3 3 200 140 200 125 200 125 — — 230 Viton 11 10 S212GF02L7DG4
5/8 4.3 3 — — — — — — 50* 50* 295 EPR 11 10 S212GH02E7DG4
IN °F
Normally Open
Valve Selection List
P P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Stainless Steel BodyType 316
( )
* Class H Coil Recommended for Steam and Other High Temperature Applications
![Page 29: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/29.jpg)
Page 29For ordering information, visit mountaincontrols.com.
S21 Series
Dimensions/Weight
- High Performance- 1/2" NPT- Brass Body- 2-Way Piloted
Diaphragm- Normally OpenMaterials Seals: Viton®, Teflon®
Orifice: Pilot Stainless SteelMain Stainless Steel Ø 1/2”
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz availableContact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: Any
Approvals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
2.5
* Not available for all variations
Body Code 4 Body Code 2
![Page 30: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/30.jpg)
Page 30For ordering information, visit mountaincontrols.com.
S 2 1 2 G F 0 2 K 4 D G 1Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
K: VitonT: Teflon
4: ForgedBrass
2: Brass
D: 1/2” NPT G1: 1/2”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
2: NormallyOpen
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 36 36
Holding 18 19
Coil Family
Type Size
All S3
1/2 3.3 1 150 140 150 140 150 140 — — 230 Viton 8 9 S212GF02K4DG1
1/2 1/2 3.3 1 — — — — — — 100*100* 338 Teflon 8 9 S212GH02T4DG1
1/2 3.6 10 — — — — — — 150*140* 366 Teflon 8 9 S212GH02T2DG1
IN °F
Normally Closed
Valve Selection List
P P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Brass Body
( )
* Class H Coil Recommended for Steam and Other High Temperature Applications
S212 – High Performance, 1/2" NPT, Brass Body,Normally Open
![Page 31: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/31.jpg)
Page 31For ordering information, visit mountaincontrols.com.
S21 Series
Dimensions/Weight
- 3/4" NPT- Brass Body- 2-Way Piloted
Diaphragm- Normally Closed
Materials Seals: Nitrile, Viton®, Ethylene Propylene
Orifice: Pilot Stainless SteelMain Brass Ø 3/4”
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: Any
Approvals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
3.3
* Not available for all variations
![Page 32: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/32.jpg)
Page 32For ordering information, visit mountaincontrols.com.
S211 – 3/4" NPT, Brass Body, Normally Closed
S 2 1 1 G F 0 2 C 5 E G 5Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
C: EPRN: NitrileV: Viton
5: Brass E: 3/4” NPT G5: 3/4”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
1: NormallyClosed
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 36 36
Holding 13 14
Coil Family
Type Size
AC S3DC S4
3/4 6.7 4 200 150 150 100 — — — — 295 EPR 8 10 S211GF02C5EG5
3/43/4 6.7 4 200 150 150 100 150 100 — — 180 Nitrile 8 10 S211GF02N5EG5
3/4 6.7 4 200 150 150 100 150 100 — — 230 Viton 8 10 S211GF02V5EG5
3/4 6.7 4 — — — — — — 50* 50* 295 EPR 8 10 S211GH02C5EG5
IN °F
Normally Closed
Valve Selection List
P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Brass Body
( )
* Class H Coil Recommended for Steam and Other High Temperature Applications
![Page 33: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/33.jpg)
Page 33For ordering information, visit mountaincontrols.com.
S21 Series
Dimensions/Weight
- 3/4" NPT- Stainless Steel Body
Type 316- 2-Way Piloted Diaphragm- Normally Closed
Materials Seals: Nitrile, Viton®, Ethylene Propylene
Orifice: Pilot Stainless SteelMain Stainless Steel Ø 3/4”
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: Any
Approvals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
3.3
* Not available for all variations
![Page 34: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/34.jpg)
Page34For ordering information, visit mountaincontrols.com.
S211 – 3/4" NPT, Stainless Steel Body, Type 316,Normally Closed
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 36 36
Holding 13 14
Coil Family
Type Size
AC S3DC S4
S 2 1 1 G F 0 2 E 7 E G 5Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
E: EPRJ: NitrileL: Viton
7: 316 SS E: 3/4” NPT G5: 3/4”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
1: NormallyClosed
3/4 6.7 4 200 150 150 100 — — — — 295 EPR 8 10 S211GF02E7EG5
3/43/4 6.7 4 200 150 150 100 150 100 — — 180 Nitrile 8 10 S211GF02J7EG5
3/4 6.7 4 200 150 150 100 150 100 — — 230 Viton 8 10 S211GF02L7EG5
3/4 6.7 4 — — — — — — 50* 50* 295 EPR 8 10 S211GH02E7EG5
IN °F
Normally Closed
Valve Selection List
P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Stainless Steel BodyType 316
( )
* Class H Coil Recommended for Steam and Other High Temperature Applications
![Page 35: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/35.jpg)
Page 35For ordering information, visit mountaincontrols.com.
S21 Series
Dimensions/Weight
- High Performance- 3/4" NPT- Brass Body- 2-Way Piloted
Diaphragm- Normally ClosedMaterials Seals: Viton®, Teflon®
Orifice: Pilot Stainless SteelMain Stainless Steel Ø 3/4”
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz availableContact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: ± 45º From Vertical
Approvals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
3.3
* Not available for all variations
Body Code 4 Body Code 2
![Page 36: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/36.jpg)
Page36For ordering information, visit mountaincontrols.com.
S 2 1 1 G F 0 2 K 4 E G 5Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
K: VitonT: Teflon
4: ForgedBrass
2: Brass
E: 3/4” NPT G5: 3/4”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
1: NormallyClosed
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 36 36
Holding 13 14
Coil Family
Type Size
All S3
3/4 6.1 1 250 150 250 150 250150 — — 230 Viton 8 9 S211GF02K4EG5
3/4 3/4 6.1 1 — — — — — — 100*100* 338 Teflon 8 9 S211GH02T4EG5
3/4 7.0 10 — — — — — — 150*150* 366 Teflon 8 9 S211GH02T2EG5
IN °F
Normally Closed
Valve Selection List
P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Brass Body
( )
* Class H Coil Recommended for Steam and Other High Temperature Applications
S211 – High Performance, 3/4" NPT, Brass Body,Normally Closed
![Page 37: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/37.jpg)
Page 37For ordering information, visit mountaincontrols.com.
H21 Series
Dimensions/Weight
- High Pressure- 3/4" NPT- Brass Body- 2-Way Piloted
Diaphragm- Normally ClosedMaterials Seals: Viton®, Teflon®
Orifice: Pilot Stainless SteelMain Stainless Steel Ø 3/4”
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz availableContact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: Any
Approvals* Agency: UL Recognized
® Registered Trademark of DuPont Co.
Weight (lbs.)
3.3
* Not available for all variations
![Page 38: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/38.jpg)
Page38For ordering information, visit mountaincontrols.com.
VALVES
H211 - High Pressure, 3/4" NPT, Brass Body, Normally Closed
I Valve Selection List I Normally Closed Energized De-Energized
p
Q) Operating Pressure Differential (psi)
ci. Power Model CodeN MaximumQ) iii E ro N
;','j� Consumption ( 120V/60HZ-110V/50HZ)iii Q) ·� {) E Air/Gas Water Light Oil 2-:, (Watts) Shown � ;;:::: m ·c :::, � 2 a: 0
.�
AC DC AC DC AC DC ro AC DC Brass BodyCv � Q) NPT IN OF (J)
3/4 3/4 6.1 10 400 400 400 400 400 400 230 Viton/Teflor 10 10 H211 G F02Z4EG5
Part Numbering I 1 2 3 4 5 6 7 8 9 10 11 12 13
[HJ�[[] [[] [g] [EJ [Q]� � @] [fil [g][[ Series Operating Housing• Coil Class• Voltage• Seal Body Pipe Orifice SizeMode Material Material Connection
H21 1: Normally G : Conduit F : Class F 02: 120/60 Z : Viton/ 4 : Brass E: 3/4" NPT GS: 3/4"Closed 110/50 Teflon
•See the "Engineering Guide" for additional voltages, variations and options.
I I I I I I
Coil Data I Coil Family Frequency (Hz) 60 50
Type Size
All S4 Nominal Power (VA) Inrush 46 46
Holding 18 19
![Page 39: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/39.jpg)
Page 39For ordering information, visit mountaincontrols.com.
S21 Series
Dimensions/Weight
- 3/4" NPT- Brass Body- 2-Way Piloted
Diaphragm- Normally Open
Materials Seals: Nitrile, Viton®, Ethylene Propylene
Orifice: Pilot Stainless SteelMain Brass Ø 3/4”
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: Any
Approvals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
3.3
* Not available for all variations
![Page 40: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/40.jpg)
Page40For ordering information, visit mountaincontrols.com.
S212 – 3/4" NPT, Brass Body, Normally Open
S 2 1 2 G F 0 2 C 5 E G 5Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
C: EPRN: NitrileV: Viton
5: Brass E: 3/4” NPT G5: 3/4”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
2: NormallyOpen
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 46 46
Holding 22 25
Coil Family
Type Size
ALL S4
3/4 6.7 3 200 140 200 125 — — — — 295 EPR 11 10 S212GF02C5EG5
3/43/4 6.7 3 200 140 200 125 200 125 — — 180 Nitrile 11 10 S212GF02N5EG5
3/4 6.7 3 200 140 200 125 200 125 — — 230 Viton 11 10 S212GF02V5EG5
3/4 6.7 3 — — — — — — 50* 50* 295 EPR 11 10 S212GH02C5EG5
IN °F
Normally Open
Valve Selection List
P P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Brass Body
( )
* Class H Coil Recommended for Steam and Other High Temperature Applications
![Page 41: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/41.jpg)
Page41For ordering information, visit mountaincontrols.com.
S21 Series
Dimensions/Weight
- 3/4" NPT- Stainless Steel Body
Type 316- 2-Way Piloted Diaphragm- Normally Open
Materials Seals: Nitrile, Viton®, Ethylene Propylene
Orifice: Pilot Stainless SteelMain Stainless Steel Ø 3/4”
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: Any
Approvals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
3.3
* Not available for all variations
![Page 42: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/42.jpg)
Page42For ordering information, visit mountaincontrols.com.
S212 – 3/4" NPT, Stainless Steel Body, Type 316,Normally Open
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 46 46
Holding 22 25
Coil Family
Type Size
ALL S4
S 2 1 2 G F 0 2 E 7 E G 5Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
E: EPRJ: NitrileL: Viton
7: 316 SS E: 3/4” NPT G5: 3/4”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
2: NormallyOpen
3/4 6.7 3 200 140 200 125 — — — — 295 EPR 11 10 S212GF02E7EG5
3/43/4 6.7 3 200 140 200 125 200 125 — — 180 Nitrile 11 10 S212GF02J7EG5
3/4 6.7 3 200 140 200 125 200 125 — — 230 Viton 11 10 S212GF02L7EG5
3/4 6.7 3 — — — — — — 50* 50* 295 EPR 11 10 S212GH02E7EG5
IN °F
Normally Open
Valve Selection List
P P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Stainless Steel BodyType 316
( )
* Class H Coil Recommended for Steam and Other High Temperature Applications
![Page 43: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/43.jpg)
Page43For ordering information, visit mountaincontrols.com.
S21 Series
Dimensions/Weight
- High Performance- 3/4" NPT- Brass Body- 2-Way Piloted
Diaphragm- Normally OpenMaterials Seals: Viton®, Teflon®
Orifice: Pilot Stainless SteelMain Stainless Steel Ø 3/4”
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz availableContact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: Any
Approvals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
3.3
* Not available for all variations
Body Code 4 Body Code 2
![Page 44: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/44.jpg)
Page44For ordering information, visit mountaincontrols.com.
S 2 1 2 G F 0 2 K 4 E G 5Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
K: VitonT: Teflon
4: ForgedBrass
2: Brass
E: 3/4” NPT G5: 3/4”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
2: NormallyOpen
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 36 36
Holding 18 19
Coil Family
Type Size
All S3
3/4 6.1 1 150 140 150 140 150 140 — — 230 Viton 8 9 S212GF02K4EG5
3/4 3/4 6.1 1 — — — — — — 100*100* 338 Teflon 8 9 S212GH02T4EG5
3/4 7.0 10 — — — — — — 150*140* 366 Teflon 8 9 S212GH02T2EG5
IN °F
Normally Closed
Valve Selection List
P P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Brass Body
( )
* Class H Coil Recommended for Steam and Other High Temperature Applications
S211 – High Performance, 3/4" NPT, Brass Body,Normally Open
![Page 45: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/45.jpg)
Page45For ordering information, visit mountaincontrols.com.
S21 Series
296Dimensions/Weight
- 1" NPT- Brass Body- 2-Way Piloted
Diaphragm- Normally Closed
Materials Seals: Nitrile, Viton®, Ethylene Propylene
Orifice: Pilot Stainless SteelMain Brass Ø 1”
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: Vertical and UprightApprovals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
6.4
* Not available for all variations
![Page 46: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/46.jpg)
Page46For ordering information, visit mountaincontrols.com.
S211 – 1" NPT, Brass Body, Normally Closed
S 2 1 1 G F 0 2 C 5 F G 9Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
C: EPRN: NitrileV: Viton
5: Brass F: 1” NPT G9: 1”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
1: NormallyClosed
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 36 36
Holding 13 14
Coil Family
Type Size
ALL S3
1 13 5 200 150 150 150 — — — — 295 EPR 8 9 S211GF02C5FG9
1 13 5 200 150 150 150 100 100 — — 180 Nitrile 8 9 S211GF02N5FG91
1 13 5 200 150 150 150 100 100 — — 230 Viton 8 9 S211GF02V5FG9
1 13 5 — — — — — — 50* 50* 295 EPR 8 9 S211GH02C5FG9
IN °F
Normally Closed
Valve Selection List
P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Brass Body
( )
* Class H Coil Recommended for Steam and Other High Temperature Applications
![Page 47: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/47.jpg)
Page47For ordering information, visit mountaincontrols.com.
S21 Series
296Dimensions/Weight
- 1" NPT- Stainless Steel Body
Type 316- 2-Way Piloted Diaphragm- Normally Closed
Materials Seals: Nitrile, Viton®, Ethylene Propylene
Orifice: Pilot Stainless SteelMain Stainless Steel Ø 1”
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: Vertical and UprightApprovals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
6.4
* Not available for all variations
![Page 48: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/48.jpg)
Page48For ordering information, visit mountaincontrols.com.
S211 – 1" NPT, Stainless Steel Body Type 316,Normally Closed
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 36 36
Holding 13 14
Coil Family
Type Size
ALL S3
S 2 1 1 G F 0 2 E 7 F G 9Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
E: EPRJ: NitrileL: Viton
7: 316 SS F: 1” NPT G9: 1”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
1: NormallyClosed
1 13 5 200 150 150 150 — — — — 295 EPR 8 9 S211GF02E7FG9
1 13 5 200 150 150 150 100 100 — — 180 Nitrile 8 9 S211GF02J7FG91
1 13 5 200 150 150 150 100 100 — — 230 Viton 8 9 S211GF02L7FG9
1 13 5 — — — — — — 50* 50* 295 EPR 8 9 S211GH02E7FG9
IN °F
Normally Closed
Valve Selection List
P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Stainless Steel BodyType 316
( )
* Class H Coil Recommended for Steam and Other High Temperature Applications
![Page 49: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/49.jpg)
Page49For ordering information, visit mountaincontrols.com.
S21 Series
Dimensions/Weight
- High Performance- 1" NPT- Brass Body- 2-Way Piloted
Diaphragm- Normally ClosedMaterials Seals: Nitrile®, Teflon®
Orifice: Pilot Stainless SteelMain Brass Ø 1” - #4 Body; Stainless Steel Ø 1” - #2” Body
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: ±15° From Vertical
Approvals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
6.4
* Not available for all variations
![Page 50: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/50.jpg)
Page 50For ordering information, visit mountaincontrols.com.
S 2 1 1 G F 0 2 N 4 F G 9Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
N: NitrileT: Teflon/
EPR
4: Brass2: Brass
F: 1” NPT G9: 1”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
1: NormallyClosed
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 36 36
Holding 13 14
Coil Family
Type Size
All S3
11 13 10 250 150 250 150 250 150 — — 180 Nitrile 8 9 S211GF02N4FG9
1 13 10 — — — — — — 150* 150* 366 Teflon 8 9 S211GH02T2FG9
IN °F
Normally Closed
Valve Selection List
P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Brass Body
( )
* Class H Coil Recommended for Steam and Other High Temperature Applications
S211 – High Performance, 1" NPT, Brass Body,Normally Closed
![Page 51: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/51.jpg)
Page 51For ordering information, visit mountaincontrols.com.
S21 Series
Dimensions/Weight
- High Performance- 1" NPT- Stainless Steel Body
Type 316- 2-Way Piloted
Diaphragm- Normally ClosedMaterials Seals: Nitrile, Teflon®
Orifice: Pilot Stainless SteelMain Stainless Steel Ø 1”
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: ±15° From Vertical
Approvals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
6.4
* Not available for all variations
![Page 52: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/52.jpg)
Page 52For ordering information, visit mountaincontrols.com.
S211 – High Performance, 1" NPT, Stainless Steel Body-Type 316, Normally Closed
S 2 1 1 G F 0 2 N 1 F G 9Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
N: NitrileT: Teflon/
EPR
1: StainlessSteel
F: 1” NPT G9: 1”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
* Class H Coil Recommended for Steam and Other High Temperature Applications
1 2 3 4 5 6 7 8 9 10 11 12 13
1: NormallyClosed
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 36 36
Holding 13 14
Coil Family
Type Size
All S3
11 13 10 250 150 250 150 250 150 — — 180 Nitrile 8 9 S211GF02N1FG9
1 13 10 — — — — — — 150* 150* 366 Teflon 8 9 S211GH02T1FG9
IN °F
Normally Closed
Valve Selection List
P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Stainless Steel BodyType 316
( )
![Page 53: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/53.jpg)
Page 53For ordering information, visit mountaincontrols.com.
S21 Series
Dimensions/Weight
- 1" NPT- Brass Body- 2-Way Piloted
Diaphragm- Normally Open
Materials Seals: Nitrile, Viton®, Ethylene Propylene
Orifice: Pilot Stainless SteelMain Brass Ø 1”
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: Vertical and UprightApprovals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
6.4
* Not available for all variations
![Page 54: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/54.jpg)
Page54For ordering information, visit mountaincontrols.com.
S212 – 1" NPT, Brass Body, Normally Open
S 2 1 2 G F 0 2 C 5 F G 9Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
C: EPRN: NitrileV: Viton
5: Brass F: 1” NPT G9: 1”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
2: NormallyOpen
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 36 36
Holding 18 22
Coil Family
Type Size
ALL S3
1 13 5 200 140 150 140 — — — — 295 EPR 9 9 S212GF02C5FG9
1 13 5 200 140 150 140 100 100 — — 180 Nitrile 9 9 S212GF02N5FG91
1 13 5 200 140 150 140 100 100 — — 230 Viton 9 9 S212GF02V5FG9
1 13 5 — — — — — — 50* 50* 295 EPR 9 9 S212GH02C5FG9
IN °F
Normally Open
Valve Selection List
P P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Brass Body
( )
* Class H Coil Recommended for Steam and Other High Temperature Applications
![Page 55: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/55.jpg)
Page 55For ordering information, visit mountaincontrols.com.
S21 Series
Dimensions/Weight
- 1" NPT- Stainless Steel Body
Type 316- 2-Way Piloted Diaphragm- Normally Open
Materials Seals: Nitrile, Viton®, Ethylene Propylene
Orifice: Pilot Stainless SteelMain Stainless Steel Ø 1”
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: Vertical and UprightApprovals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
6.4
* Not available for all variations
![Page 56: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/56.jpg)
Page56For ordering information, visit mountaincontrols.com.
S212 – 1" NPT, Stainless Steel Body, Type 316,Normally Open
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 36 36
Holding 18 19
Coil Family
Type Size
ALL S3
S 2 1 2 G F 0 2 E 7 F G 9Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
E: EPRJ: NitrileL: Viton
7: 316 SS F: 1” NPT G9: 1”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
2: NormallyOpen
1 13 5 200 150 150 150 — — — — 295 EPR 9 9 S212GF02E7FG9
1 13 5 200 150 150 150 85 85 — — 180 Nitrile 9 9 S212GF02J7FG91
1 13 5 200 150 150 150 85 85 — — 230 Viton 9 9 S212GF02L7FG9
1 13 5 — — — — — — 50* 50* 295 EPR 9 9 S212GH02E7FG9
IN °F
Normally Open
Valve Selection List
P P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Stainless Steel BodyType 316
( )
* Class H Coil Recommended for Steam and Other High Temperature Applications
![Page 57: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/57.jpg)
Page 57For ordering information, visit mountaincontrols.com.
S21 Series
Dimensions/Weight
Materials Seals: Nitrile, Teflon®
Orifice: Pilot Stainless SteelMain Stainless Steel Ø 1”
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: ±15° From Vertical
Approvals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
6.4
* Not available for all variations
- High Performance- 1" NPT- Stainless Steel Body
Type 316- 2-Way Piloted
Diaphragm- Normally Open
![Page 58: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/58.jpg)
Page58For ordering information, visit mountaincontrols.com.
S212 – High Performance, 1" NPT, Stainless Steel Body-Type 316, Normally Open
S 2 1 2 G F 0 2 N 1 F G 9Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
N: NitrileT: Teflon/
EPR
1: StainlessSteel
F: 1” NPT G9: 1”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
2: NormallyOpen
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 36 36
Holding 18 22
Coil Family
Type Size
All S3
11/2 3.3 1 200 140 200 140 200 140 — — 230 Nitrile 8 9 S212GF02N1FG9
1/2 3.3 10 — — — — — — 100*100* 366 Teflon 8 9 S212GH02T1FG9
IN °F
Normally Open
Valve Selection List
P P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Stainless Steel BodyType 316
( )
* Class H Coil Recommended for Steam and Other High Temperature Applications
![Page 59: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/59.jpg)
Page 59For ordering information, visit mountaincontrols.com.
S21 Series
Dimensions/Weight
- 1 1/4" NPT- Brass Body- 2-Way Piloted
Diaphragm- Normally Closed
Materials Seals: Nitrile, Viton®, Ethylene Propylene
Orifice: Pilot Stainless SteelMain Brass Ø 1 1/4”
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: Vertical and UprightApprovals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
10.5
* Not available for all variations
![Page 60: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/60.jpg)
Page60For ordering information, visit mountaincontrols.com.
S211 – 1 1/4" NPT, Brass Body, Normally Closed
S 2 1 1 G F 0 2 C 5 G J 2Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
C: EPRN: NitrileV: Viton
5: Brass G: 1 1/4” NPT J2: 1 1/4”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
1: NormallyClosed
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 36 36
Holding 13 14
Coil Family
Type Size
ALL S3
1 1/4 19 5 200 150 150 150 — — — — 295 EPR 8 9 S211GF02C5GJ2
1 1/4 19 5 200 150 150 150 100 100 — — 180 Nitrile 8 9 S211GF02N5GJ21 1/4
1 1/4 19 5 200 150 150 150 100 100 — — 230 Viton 8 9 S211GF02V5GJ2
1 1/4 19 5 — — — — — — 50* 50* 295 EPR 8 9 S211GH02C5GJ2
IN °F
Normally Closed
Valve Selection List
P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Brass Body
( )
* Class H Coil Recommended for Steam and Other High Temperature Applications
![Page 61: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/61.jpg)
Page61For ordering information, visit mountaincontrols.com.
S21 Series
Dimensions/Weight
- 1 1/4" NPT- Stainless Steel Body
Type 316- 2-Way Piloted Diaphragm- Normally Closed
Materials Seals: Nitrile, Viton®, Ethylene Propylene
Orifice: Pilot Stainless SteelMain Stainless Steel Ø 1 1/4”
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: Vertical and UprightApprovals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
10.5
* Not available for all variations
![Page 62: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/62.jpg)
Page62For ordering information, visit mountaincontrols.com.
S211 – 1 1/4" NPT, Stainless Steel Body, Type 316,Normally Closed
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 36 36
Holding 13 14
Coil Family
Type Size
ALL S3
S 2 1 1 G F 0 2 E 7 G J 2Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
E: EPRJ: NitrileL: Viton
7: 316 SS G: 1 1/4” NPT J2: 1 1/4”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
1: NormallyClosed
1 1/4 19 10 200 150 150 150 — — — — 295 EPR 8 9 S211GF02E7GJ2
1 1/4 19 5 200 150 150 150 85 85 — — 180 Nitrile 8 9 S211GF02J7GJ21 1/4
1 1/4 19 10 200 150 150 150 85 85 — — 230 Viton 8 9 S211GF02L7GJ2
1 1/4 19 5 — — — — — — 50* 50* 295 EPR 8 9 S211GH02E7GJ2
IN °F
Normally Closed
Valve Selection List
P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Stainless Steel BodyType 316
( )
* Class H Coil Recommended for Steam and Other High Temperature Applications
![Page 63: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/63.jpg)
Page63For ordering information, visit mountaincontrols.com.
S21 Series
326ADimensions/Weight
- High Performance- 1 1/4" NPT- Brass Body- 2-Way Piloted
Diaphragm- Normally ClosedMaterials Seals: Nitrile®, Teflon®
Orifice: Pilot Stainless SteelMain Brass Ø 1 1/2” - #4 Body; Stainless Steel Ø 1 1/2” - #2” Body
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: ±15° From Vertical
Approvals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
10.5
* Not available for all variations
![Page 64: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/64.jpg)
Page64For ordering information, visit mountaincontrols.com.
S 2 1 1 G F 0 2 N 4 G J 5Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
N: NitrileT: Teflon/
EPR
4: Brass2: Brass
G: 1 1/4” NPT J5: 1 1/2”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
1: NormallyClosed
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 36 36
Holding 13 14
Coil Family
Type Size
All S3
1 1/41 1/2 22 10 250 150 250 150 250 150 — — 180 Nitrile 8 9 S211GF02N4GJ5
1 1/2 22 10 — — — — — — 150* 150* 366 Teflon 8 9 S211GH02T2GJ5
IN °F
Normally Closed
Valve Selection List
P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Brass Body
( )
* Class H Coil Recommended for Steam and Other High Temperature Applications
S211 – High Performance, 1 1/4" NPT, Brass Body,Normally Closed
![Page 65: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/65.jpg)
Page65For ordering information, visit mountaincontrols.com.
S21 Series
326ADimensions/Weight
- High Performance- 1 1/4" NPT- Stainless Steel Body
Type 316- 2-Way Piloted
Diaphragm- Normally ClosedMaterials Seals: Nitrile, Teflon®
Orifice: Pilot Stainless SteelMain Stainless Steel Ø 1 1/2”
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: ±15° From Vertical
Approvals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
10.5
* Not available for all variations
![Page 66: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/66.jpg)
Page66For ordering information, visit mountaincontrols.com.
S 2 1 1 G F 0 2 N 1 G J 5Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
N: NitrileT: Teflon/
EPR
1: StainlessSteel
G: 1 1/4” NPT J5: 1 1/2”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
1: NormallyClosed
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 36 36
Holding 13 14
Coil Family
Type Size
All S3
1 1/41 1/2 22 10 250 150 250 150 250 150 — — 180 Nitrile 8 9 S211GF02N1GJ5
1 1/2 22 10 — — — — — — 150* 150* 366 Teflon 8 9 S211GH02T1GJ5
IN °F
Normally Closed
Valve Selection List
P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Stainless Steel BodyType 316
( )
* Class H Coil Recommended for Steam and Other High Temperature Applications
S211 – High Performance, 1 1/4" NPT, Stainless Steel Body-Type 316, Normally Closed
![Page 67: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/67.jpg)
Page67For ordering information, visit mountaincontrols.com.
S21 Series
Dimensions/Weight
- 1 1/4" NPT- Brass Body- 2-Way Piloted
Diaphragm- Normally Open
Materials Seals: Nitrile, Viton®, Ethylene Propylene
Orifice: Pilot Stainless SteelMain Brass Ø 1 1/4”
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: Vertical and UprightApprovals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
10.5
* Not available for all variations
![Page 68: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/68.jpg)
Page68For ordering information, visit mountaincontrols.com.
S212 – 1 1/4" NPT, Brass Body, Normally Open
S 2 1 2 G F 0 2 C 5 G J 2Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
C: EPRN: NitrileV: Viton
5: Brass G: 1 1/4” NPT J2: 1 1/4”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
2: NormallyOpen
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 36 36
Holding 18 22
Coil Family
Type Size
ALL S3
1 1/4 19 5 200 140 140 140 — — — — 295 EPR 9 9 S212GF02C5GJ2
1 1/4 19 5 200 140 140 140 85 85 — — 180 Nitrile 9 9 S212GF02N5GJ21 1/4
1 1/4 19 5 200 140 140 140 85 85 — — 230 Viton 9 9 S212GF02V5GJ2
1 1/4 19 5 — — — — — — 50* 50* 295 EPR 9 9 S212GH02C5GJ2
IN °F
Normally Open
Valve Selection List
P P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Brass Body
( )
* Class H Coil Recommended for Steam and Other High Temperature Applications
![Page 69: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/69.jpg)
Page69For ordering information, visit mountaincontrols.com.
S21 Series
Dimensions/Weight
- 1 1/4" NPT- Stainless Steel Body
Type 316- 2-Way Piloted Diaphragm- Normally Open
Materials Seals: Nitrile, Viton®, Ethylene Propylene
Orifice: Pilot Stainless SteelMain Stainless Steel Ø 1 1/4”
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: Vertical and UprightApprovals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
10.5
* Not available for all variations
![Page 70: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/70.jpg)
Page 70For ordering information, visit mountaincontrols.com.
S212 – 1 1/4" NPT, Stainless Steel Body, Type 316,Normally Open
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 36 36
Holding 18 19
Coil Family
Type Size
ALL S3
S 2 1 2 G F 0 2 E 7 G J 2Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
E: EPRJ: NitrileL: Viton
7: 316 SS G: 1 1/4” NPT J2: 1 1/4”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
2: NormallyOpen
1 1/4 19 5 200 150 150 150 85 85 — — 295 EPR 9 9 S212GF02E7GJ2
1 1/4 19 5 200 150 150 150 85 85 — — 180 Nitrile 9 9 S212GF02J7GJ21 1/4
1 1/4 19 5 200 150 150 150 85 85 — — 230 Viton 9 9 S212GF02L7GJ2
1 1/4 19 5 — — — — — — 50* 50* 295 EPR 9 9 S212GH02E7GJ2
IN °F
Normally Open
Valve Selection List
P P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Stainless Steel BodyType 316
( )
* Class H Coil Recommended for Steam and Other High Temperature Applications
![Page 71: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/71.jpg)
Page 71For ordering information, visit mountaincontrols.com.
S21 Series
Dimensions/Weight
- High Performance- 1 1/4" NPT- Brass Body- 2-Way Piloted
Diaphragm- Normally OpenMaterials Seals: Nitrile, Teflon®
Orifice: Pilot Stainless SteelMain Brass Ø 1 1/2” - #4 Body; Stainless Steel Ø 1 1/2” - #2 Body
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: ±15° From Vertical
Approvals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
10.5
* Not available for all variations
![Page 72: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/72.jpg)
Page 72For ordering information, visit mountaincontrols.com.
S 2 1 2 G F 0 2 N 4 G J 5Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
N: NitrileT: Teflon/
EPR
4: ForgedBrass
2: Brass
G: 1 1/4” NPT J5: 1 1/2”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
2: NormallyOpen
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 36 36
Holding 18 22
Coil Family
Type Size
All S3
1 1/41 1/2 22 10 200 140 200 140 200 140 — — 180 Nitrile 8 9 S212GF02N4GJ5
1 1/2 22 10 — — — — — — 100*100* 366 Teflon 8 9 S212GH02T2GJ5
IN °F
Normally Open
Valve Selection List
P P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Brass Body
( )
* Class H Coil Recommended for Steam and Other High Temperature Applications
S211 – High Performance, 1 1/4" NPT, Brass Body,Normally Open
![Page 73: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/73.jpg)
Page 73For ordering information, visit mountaincontrols.com.
S21 Series
Dimensions/Weight
- High Performance- 1 1/4" NPT- Stainless Steel Body
Type 316- 2-Way Piloted
Diaphragm- Normally OpenMaterials Seals: Nitrile, Teflon®
Orifice: Pilot Stainless SteelMain Stainless Steel Ø 1 1/2”
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: ±15° From Vertical
Approvals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
10.5
* Not available for all variations
![Page 74: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/74.jpg)
Page74For ordering information, visit mountaincontrols.com.
S212 – High Performance, 1 1/4" NPT, Stainless SteelBody-Type 316, Normally Open
S 2 1 2 G F 0 2 N 1 G J 5Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
N: NitrileT: Teflon/
EPR
1: StainlessSteel
G: 1 1/4” NPT J5: 1 1/2”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
2: NormallyOpen
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 36 36
Holding 18 22
Coil Family
Type Size
All S3
1 1/41 1/2 22 10 200 140 200 140 200 140 — — 180 Nitrile 8 9 S212GF02N1GJ5
1 1/2 22 10 — — — — — — 100*100* 366 Teflon 8 9 S212GH02T1GJ5
IN °F
Normally Open
Valve Selection List
P P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Stainless Steel BodyType 316
( )
* Class H Coil Recommended for Steam and Other High Temperature Applications
![Page 75: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/75.jpg)
Page 75For ordering information, visit mountaincontrols.com.
S21 Series
308Dimensions/Weight
- 1 1/2" NPT- Brass Body- 2-Way Piloted
Diaphragm- Normally Closed
Materials Seals: Nitrile, Viton®, Ethylene Propylene
Orifice: Pilot Stainless SteelMain Brass Ø 1 1/4”
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: Vertical and UprightApprovals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
10.5
* Not available for all variations
![Page 76: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/76.jpg)
Page76For ordering information, visit mountaincontrols.com.
S211 – 1 1/2" NPT, Brass Body, Normally Closed
S 2 1 1 G F 0 2 C 5 H J 2Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
C: EPRN: NitrileV: Viton
5: Brass H: 1 1/2” NPT J2: 1 1/4”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
1: NormallyClosed
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 36 36
Holding 13 14
Coil Family
Type Size
ALL S3
1 1/4 25 5 200 150 150 150 — — — — 295 EPR 8 9 S211GF02C5HJ2
1 1/4 25 5 200 150 150 150 85 85 — — 180 Nitrile 8 9 S211GF02N5HJ21 1/2
1 1/4 25 5 200 150 150 150 85 85 — — 230 Viton 8 9 S211GF02V5HJ2
1 1/4 25 5 — — — — — — 50* 50* 295 EPR 8 9 S211GH02C5HJ2
IN °F
Normally Closed
Valve Selection List
P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Brass Body
( )
* Class H Coil Recommended for Steam and Other High Temperature Applications
![Page 77: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/77.jpg)
Page 77For ordering information, visit mountaincontrols.com.
S21 Series
308Dimensions/Weight
- 1 1/2" NPT- Stainless Steel Body
Type 316- 2-Way Piloted Diaphragm- Normally Closed
Materials Seals: Nitrile, Viton®, Ethylene Propylene
Orifice: Pilot Stainless SteelMain Stainless Steel Ø 1 1/4”
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: Vertical and UprightApprovals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
10.5
* Not available for all variations
![Page 78: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/78.jpg)
Page78For ordering information, visit mountaincontrols.com.
S211 – 1 1/2" NPT, Stainless Steel Body, Type 316,Normally Closed
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 36 36
Holding 13 14
Coil Family
Type Size
ALL S3
S 2 1 1 G F 0 2 E 7 H J 2Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
E: EPRJ: NitrileL: Viton
7: 316 SS H: 1 1/2” NPT J2: 1 1/4”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
1: NormallyClosed
1 1/4 25 5 200 150 150 150 — — — — 295 EPR 8 9 S211GF02E7HJ2
1 1/4 25 5 200 150 150 150 85 85 — — 180 Nitrile 8 9 S211GF02J7HJ21 1/2
1 1/4 25 5 200 150 150 150 85 85 — — 230 Viton 8 9 S211GF02L7HJ2
1 1/4 25 5 — — — — — — 50* 50* 295 EPR 8 9 S211GH02E7HJ2
IN °F
Normally Closed
Valve Selection List
P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Stainless Steel BodyType 316
( )
* Class H Coil Recommended for Steam and Other High Temperature Applications
![Page 79: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/79.jpg)
Page 79For ordering information, visit mountaincontrols.com.
326A
S21 Series
Dimensions/Weight
- High Performance- 1 1/2" NPT- Brass Body- 2-Way Piloted
Diaphragm- Normally ClosedMaterials Seals: Nitrile®, Teflon®
Orifice: Pilot Stainless SteelMain Brass Ø 1 1/2” - #4 Body; Stainless Steel Ø 1 1/2” - #2” Body
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: ±15° From Vertical
Approvals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
10.5
* Not available for all variations
![Page 80: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/80.jpg)
Page80For ordering information, visit mountaincontrols.com.
S 2 1 1 G F 0 2 N 4 H J 5Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
N: NitrileT: Teflon/
EPR
4: Brass2: Brass
H: 1 1/2” NPT J5: 1 1/2”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
1: NormallyClosed
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 36 36
Holding 13 14
Coil Family
Type Size
All S3
1 1/21 1/2 28 10 250 150 250 150 250 150 — — 180 Nitrile 8 9 S211GF02N4HJ5
1 1/2 28 10 — — — — — — 150* 150* 366 Teflon 8 9 S211GH02T2HJ5
IN °F
Normally Closed
Valve Selection List
P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Brass Body
( )
* Class H Coil Recommended for Steam and Other High Temperature Applications
S211 – High Performance, 1 1/2" NPT, Brass Body,Normally Closed
![Page 81: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/81.jpg)
Page81For ordering information, visit mountaincontrols.com.
S21 Series
326BDimensions/Weight
- High Performance- 1 1/2" NPT- Stainless Steel Body
Type 316- 2-Way Piloted
Diaphragm- Normally ClosedMaterials Seals: Nitrile, Teflon®
Orifice: Pilot Stainless SteelMain Stainless Steel Ø 1 1/2”
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: ±15° From Vertical
Approvals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
10.5
* Not available for all variations
![Page 82: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/82.jpg)
Page82For ordering information, visit mountaincontrols.com.
S 2 1 1 G F 0 2 N 1 H J 5Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
N: NitrileT: Teflon/
EPR
1: StainlessSteel
H: 1 1/2” NPT J5: 1 1/2”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
1: NormallyClosed
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 36 36
Holding 13 14
Coil Family
Type Size
All S3
1 1/21 1/2 28 10 250 150 250 150 250 150 — — 180 Nitrile 8 9 S211GF02N1HJ5
1 1/2 28 10 — — — — — — 150* 150* 366 Teflon 8 9 S211GH02T1HJ5
IN °F
Normally Closed
Valve Selection List
P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Stainless Steel BodyType 316
( )
* Class H Coil Recommended for Steam and Other High Temperature Applications
S211 – High Performance, 1 1/2" NPT, Stainless Steel Body-Type 316, Normally Closed
![Page 83: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/83.jpg)
Page83For ordering information, visit mountaincontrols.com.
S21 Series
Dimensions/Weight
- 1 1/2" NPT- Brass Body- 2-Way Piloted
Diaphragm- Normally Open
Materials Seals: Nitrile, Viton®, Ethylene Propylene
Orifice: Pilot Stainless SteelMain Brass Ø 1 1/4”
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: Vertical and UprightApprovals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
10.5
* Not available for all variations
![Page 84: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/84.jpg)
Page84For ordering information, visit mountaincontrols.com.
S212 – 1 1/2" NPT, Brass Body, Normally Open
S 2 1 2 G F 0 2 C 5 H J 2Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
C: EPRN: NitrileV: Viton
5: Brass H: 1 1/2” NPT J2: 1 1/4”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
2: NormallyOpen
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 36 36
Holding 18 22
Coil Family
Type Size
ALL S3
1 1/4 25 3 200 140 140 140 — — — — 295 EPR 9 9 S212GF02C5HJ2
1 1/4 25 3 200 140 140 140 85 85 — — 180 Nitrile 9 9 S212GF02N5HJ21 1/2
1 1/4 25 3 200 140 140 140 85 85 — — 230 Viton 9 9 S212GF02V5HJ2
1 1/4 25 3 — — — — — — 50* 50* 295 EPR 9 9 S212GH02C5HJ2
IN °F
Normally Open
Valve Selection List
P P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Brass Body
( )
* Class H Coil Recommended for Steam and Other High Temperature Applications
![Page 85: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/85.jpg)
Page85For ordering information, visit mountaincontrols.com.
S21 Series
Dimensions/Weight
- 1 1/2" NPT- Stainless Steel Body
Type 316- 2-Way Piloted Diaphragm- Normally Open
Materials Seals: Nitrile, Viton®, Ethylene Propylene
Orifice: Pilot Stainless SteelMain Stainless Steel Ø 1 1/4”
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: Vertical and UprightApprovals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
10.5
* Not available for all variations
![Page 86: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/86.jpg)
Page86For ordering information, visit mountaincontrols.com.
S212 – 1 1/2" NPT, Stainless Steel Body, Type 316,Normally Open
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 36 36
Holding 18 19
Coil Family
Type Size
ALL S3
S 2 1 2 G F 0 2 E 7 H J 2Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
E: EPRJ: NitrileL: Viton
7: 316 SS H: 1 1/2” NPT J2: 1 1/4”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
2: NormallyOpen
1 1/4 25 5 200 150 150 150 — — — — 295 EPR 9 9 S212GF02E7HJ2
1 1/4 25 5 200 150 150 150 85 85 — — 180 Nitrile 9 9 S212GF02J7HJ21 1/2
1 1/4 25 5 200 150 150 150 85 85 — — 230 Viton 9 9 S212GF02L7HJ2
1 1/4 25 5 — — — — — — 50* 50* 295 EPR 9 9 S212GH02E7HJ2
IN °F
Normally Open
Valve Selection List
P P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Stainless Steel BodyType 316
( )
* Class H Coil Recommended for Steam and Other High Temperature Applications
![Page 87: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/87.jpg)
Page87For ordering information, visit mountaincontrols.com.
S21 Series
Dimensions/Weight
- High Performance- 1 1/2" NPT- Brass Body- 2-Way Piloted
Diaphragm- Normally OpenMaterials Seals: Nitrile, Teflon®
Orifice: Pilot Stainless SteelMain Brass Ø 1 1/2” - #4 Body; Stainless Steel Ø 1 1/2” - #2 Body
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: ±15° From Vertical
Approvals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
10.5
* Not available for all variations
![Page 88: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/88.jpg)
Page88For ordering information, visit mountaincontrols.com.
S 2 1 2 G F 0 2 N 4 H J 5Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
N: NitrileT: Teflon/
EPR
4: ForgedBrass
2: Brass
H: 1 1/2” NPT J5: 1 1/2”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
2: NormallyOpen
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 36 36
Holding 18 22
Coil Family
Type Size
All S3
1 1/21 1/2 28 10 200 140 200 140 200 140 — — 180 Nitrile 8 9 S212GF02N4HJ5
1 1/2 28 10 — — — — — — 100* 100* 366 Teflon 8 9 S212GH02T2HJ5
IN °F
Normally Open
Valve Selection List
P P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Brass Body
( )
* Class H Coil Recommended for Steam and Other High Temperature Applications
S211 – High Performance, 1 1/2" NPT, Brass Body,Normally Open
![Page 89: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/89.jpg)
Page89For ordering information, visit mountaincontrols.com.
S21 Series
Dimensions/Weight
- High Performance- 1 1/2" NPT- Stainless Steel Body
Type 316- 2-Way Piloted
Diaphragm- Normally OpenMaterials Seals: Nitrile, Teflon®
Orifice: Pilot Stainless SteelMain Stainless Steel Ø 1 1/2”
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: ±15° From Vertical
Approvals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
10.5
* Not available for all variations
![Page 90: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/90.jpg)
Page 90For ordering information, visit mountaincontrols.com.
S212 – High Performance, 1 1/2" NPT, Stainless SteelBody-Type 316, Normally Open
S 2 1 2 G F 0 2 N 1 H J 5Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
N: NitrileT: Teflon/
EPR
1: StainlessSteel
H: 1 1/2” NPT J5: 1 1/2”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
2: NormallyOpen
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 36 36
Holding 18 22
Coil Family
Type Size
All S3
1 1/21 1/2 28 10 200 140 200 140 200 140 — — 180 Nitrile 8 9 S212GF02N1HJ5
1 1/2 28 10 — — — — — — 100* 100* 366 Teflon 8 9 S212GH02T1HJ5
IN °F
Normally Open
Valve Selection List
P P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Stainless Steel BodyType 316
( )
* Class H Coil Recommended for Steam and Other High Temperature Applications
![Page 91: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/91.jpg)
Page 91For ordering information, visit mountaincontrols.com.
S21 Series
318Dimensions/Weight
- 2" NPT- Brass Body- 2-Way Piloted
Diaphragm- Normally Closed
Materials Seals: Nitrile, Viton®, Ethylene Propylene
Orifice: Pilot Stainless SteelMain Brass Ø 1 1/4”
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: Vertical and UprightApprovals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
13.5
* Not available for all variations
![Page 92: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/92.jpg)
Page 92For ordering information, visit mountaincontrols.com.
S211 – 2" NPT, Brass Body, Normally Closed
S 2 1 1 G F 0 2 C 5 J J 2Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
C: EPRN: NitrileV: Viton
5: Brass J: 2” NPT J2: 1 1/4”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
1: NormallyClosed
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 36 36
Holding 13 14
Coil Family
Type Size
ALL S3
1 1/4 28 5 200 150 150 150 — — — — 295 EPR 8 9 S211GF02C5JJ2
1 1/4 28 5 200 150 150 150 85 85 — — 180 Nitrile 8 9 S211GF02N5JJ22
1 1/4 28 5 200 150 150 150 85 85 — — 230 Viton 8 9 S211GF02V5JJ2
1 1/4 28 5 — — — — — — 50* 50* 295 EPR 8 9 S211GH02C5JJ2
IN °F
Normally Closed
Valve Selection List
P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Brass Body
( )
* Class H Coil Recommended for Steam and Other High Temperature Applications
![Page 93: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/93.jpg)
Page 93For ordering information, visit mountaincontrols.com.
S21 Series
318Dimensions/Weight
- 2" NPT- Stainless Steel Body
Type 316- 2-Way Piloted Diaphragm- Normally Closed
Materials Seals: Nitrile, Viton®, Ethylene Propylene
Orifice: Pilot Stainless SteelMain Stainless Steel Ø 1 1/4”
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: Vertical and UprightApprovals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
13.5
* Not available for all variations
![Page 94: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/94.jpg)
Page94For ordering information, visit mountaincontrols.com.
S211 – 2" NPT, Stainless Steel Body, Type 316,Normally Closed
S 2 1 1 G F 0 2 E 7 J J 2Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
E: EPRJ: NitrileL: Viton
7: 316 SS J: 2” NPT J2: 1 1/4”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
1: NormallyClosed
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 36 36
Holding 13 14
Coil Family
Type Size
ALL S3
1 1/4 28 5 200 150 150 150 — — — — 295 EPR 8 9 S211GF02E7JJ2
1 1/4 28 5 200 150 150 150 85 85 — — 180 Nitrile 8 9 S211GF02J7JJ22
1 1/4 28 5 200 150 150 150 85 85 — — 230 Viton 8 9 S211GF02L7JJ2
1 1/4 28 5 — — — — — — 50* 50* 295 EPR 8 9 S211GH02E7JJ2
IN °F
Normally Closed
Valve Selection List
P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Stainless Steel BodyType 316
( )
* Class H Coil Recommended for Steam and Other High Temperature Applications
![Page 95: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/95.jpg)
Page 95For ordering information, visit mountaincontrols.com.
S21 Series
328Dimensions/Weight
- High Performance- 2" NPT- Brass Body- 2-Way Piloted
Diaphragm- Normally ClosedMaterials Seals: Nitrile®, Teflon®
Orifice: Pilot Stainless SteelMain Brass Ø 1 1/2” - #4 Body; Stainless Steel Ø 1 1/2” - #2 Body
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz availableContact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: ±15° From Vertical
Approvals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
10.5
* Not available for all variations
![Page 96: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/96.jpg)
Page96For ordering information, visit mountaincontrols.com.
S 2 1 1 G F 0 2 N 4 J J 5Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
N: NitrileT: Teflon/
EPR
4: Brass2: Brass
J: 2” NPT J5: 1 1/2”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
1: NormallyClosed
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 36 36
Holding 13 14
Coil Family
Type Size
All S3
21 1/2 29 10 250 150 250 150 250 150 — — 180 Nitrile 8 9 S211GF02N4JJ5
1 1/2 29 10 — — — — — — 150*150* 366 Teflon 8 9 S211GH02T2JJ5
IN °F
Normally Closed
Valve Selection List
P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Brass Body
( )
* Class H Coil Recommended for Steam and Other High Temperature Applications
S211 – High Performance, 2" NPT, Brass Body,Normally Closed
![Page 97: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/97.jpg)
Page 97For ordering information, visit mountaincontrols.com.
S21 Series
328Dimensions/Weight
- High Performance- 2" NPT- Stainless Steel Body
Type 316- 2-Way Piloted
Diaphragm- Normally ClosedMaterials Seals: Nitrile, Teflon®
Orifice: Pilot Stainless SteelMain Stainless Steel Ø 1 1/2”
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz availableContact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: ±15° From Vertical
Approvals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
10.5
* Not available for all variations
![Page 98: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/98.jpg)
Page98For ordering information, visit mountaincontrols.com.
S 2 1 1 G F 0 2 N 1 J J 5Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
N: NitrileT: Teflon/
EPR
1: StainlessSteel
J: 2” NPT J5: 1 1/2”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
1: NormallyClosed
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 36 36
Holding 13 14
Coil Family
Type Size
All S3
21 1/2 29 10 250 150 250 150 250 150 — — 180 Nitrile 8 9 S211GF02N1JJ5
1 1/2 29 10 — — — — — — 150*150* 366 Teflon 8 9 S211GH02T1JJ5
IN °F
Normally Closed
Valve Selection List
P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Stainless Steel BodyType 316
( )
* Class H Coil Recommended for Steam and Other High Temperature Applications
S211 – High Performance, 2" NPT, Stainless Steel Body-Type 316, Normally Closed
![Page 99: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/99.jpg)
Page 99For ordering information, visit mountaincontrols.com.
S21 Series
Dimensions/Weight
- 2" NPT- Brass Body- 2-Way Piloted
Diaphragm- Normally Open
Materials Seals: Nitrile, Viton®, Ethylene Propylene
Orifice: Pilot Stainless SteelMain Brass Ø 1 1/4”
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: Vertical and UprightApprovals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
13.5
* Not available for all variations
![Page 100: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/100.jpg)
Page 100For ordering information, visit mountaincontrols.com.
S212 – 2" NPT, Brass Body, Normally Open
S 2 1 2 G F 0 2 C 5 J J 2Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
C: EPRN: NitrileV: Viton
5: Brass J: 2” NPT J2: 1 1/4”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
2: NormallyOpen
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 36 36
Holding 18 22
Coil Family
Type Size
ALL S3
IN °F
Normally Open
Valve Selection List
P P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Brass Body
( )
* Class H Coil Recommended for Steam and Other High Temperature Applications
1 1/4 28 5 200 140 140 140 — — — — 295 EPR 9 9 S212GF02C5JJ2
1 1/4 28 5 200 140 140 140 85 85 — — 180 Nitrile 9 9 S212GF02N5JJ22
1 1/4 28 5 200 140 140 140 85 85 — — 230 Viton 9 9 S212GF02V5JJ2
1 1/4 28 5 — — — — — — 50* 50* 295 EPR 9 9 S212GH02C5JJ2
![Page 101: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/101.jpg)
Page 101For ordering information, visit mountaincontrols.com.
S21 Series
Dimensions/Weight
- 2" NPT- Stainless Steel Body
Type 316- 2-Way Piloted Diaphragm- Normally Open
Materials Seals: Nitrile, Viton®, Ethylene Propylene
Orifice: Pilot Stainless SteelMain Stainless Steel Ø 1 1/4”
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz available6, 12, 24 DC; Contact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: Vertical and UprightApprovals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
13.5
* Not available for all variations
![Page 102: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/102.jpg)
Page 102For ordering information, visit mountaincontrols.com.
S212 – 2" NPT, Stainless Steel Body, Type 316,Normally Open
S 2 1 2 G F 0 2 E 7 J J 2Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
E: EPRJ: NitrileL: Viton
7: 316 SS J: 2” NPT J2: 1 1/4”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
2: NormallyOpen
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 36 36
Holding 18 19
Coil Family
Type Size
ALL S3
1 1/4 28 5 200 150 150 150 — — — — 295 EPR 9 9 S212GF02E7JJ2
1 1/4 28 5 200 150 150 150 85 85 — — 180 Nitrile 9 9 S212GF02J7JJ22
1 1/4 28 5 200 150 150 150 85 85 — — 230 Viton 9 9 S212GF02L7JJ2
1 1/4 28 5 — — — — — — 50* 50* 295 EPR 9 9 S212GH02E7JJ2
IN °F
Normally Open
Valve Selection List
P P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Stainless Steel BodyType 316
( )
* Class H Coil Recommended for Steam and Other High Temperature Applications
![Page 103: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/103.jpg)
Page 103For ordering information, visit mountaincontrols.com.
S21 Series
Dimensions/Weight
- High Performance- 2" NPT- Brass Body- 2-Way Piloted
Diaphragm- Normally OpenMaterials Seals: Nitrile, Teflon®
Orifice: Pilot Stainless SteelMain Brass Ø 1 1/2” - #4 Body; Stainless Steel Ø 1 1/2” - #2 Body
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz availableContact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: ±15° From Vertical
Approvals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
10.5
* Not available for all variations
![Page 104: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/104.jpg)
Page104For ordering information, visit mountaincontrols.com.
S 2 1 2 G F 0 2 N 4 J J 5Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
N: NitrileT: Teflon/
EPR
4: ForgedBrass
2: Brass
J: 2” NPT J5: 1 1/2”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
2: NormallyOpen
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 36 36
Holding 18 22
Coil Family
Type Size
All S3
21 1/2 28 10 200 140 200 140 200 140 — — 180 Nitrile 8 9 S212GF02N4JJ5
1 1/2 28 10 — — — — — — 100*100* 366 Teflon 8 9 S212GH02T2JJ5
IN °F
Normally Open
Valve Selection List
P P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Brass Body
( )
* Class H Coil Recommended for Steam and Other High Temperature Applications
S211 – High Performance, 2" NPT, Brass Body,Normally Open
![Page 105: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/105.jpg)
Page 105For ordering information, visit mountaincontrols.com.
S21 Series
Dimensions/Weight
- High Performance- 2" NPT- Stainless Steel Body
Type 316- 2-Way Piloted
Diaphragm- Normally OpenMaterials Seals: Nitrile, Teflon®
Orifice: Pilot Stainless SteelMain Stainless Steel Ø 1 1/2”
Electrical Standard Housing: Encapsulated Waterproof Conduit (NEMA 4/4X)
Optional Housings: Metallic Conduit, Explosion-proof (NEMA 7), Grommet, Open Frame, Junction Box (single or dual knockouts), DIN; Contact GC Valves Customer Service for others.
Standard Voltages: 24, 120, 240 AC 60 Hz; 50 Hz availableContact GC Valves Customer Service for Additional Voltages.
Voltage Tolerance: ±10% of applicable voltage
Coil Classes: F, H, N
Standard Lead Length: 24 inch
Operating Temperature Ambient (Nominal): 32°F to 125°F
Mounting Position: ±15° From Vertical
Approvals* Agency: UL Listed, UL Recognized, CSA Approved
® Registered Trademark of DuPont Co.
Weight (lbs.)
10.5
* Not available for all variations
![Page 106: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/106.jpg)
Page106For ordering information, visit mountaincontrols.com.
S212 – High Performance, 2" NPT, Stainless Steel Body-Type 316, Normally Open
S 2 1 2 G F 0 2 N 1 J J 5Series Operating
ModeHousing* Coil Class* Voltage* Seal
MaterialBody
MaterialPipe
Connection Orifice Size
S21 G: Conduit F: Class FH: Class H
02: 120/60110/50
N: NitrileT: Teflon/
EPR
1: StainlessSteel
J: 2” NPT J5: 1 1/2”
Part Numbering
* See the “Engineering Guide” for additional voltages, variations and options.
1 2 3 4 5 6 7 8 9 10 11 12 13
2: NormallyOpen
Coil Data
Frequency (Hz) 60 50
Nominal Power (VA) Inrush 36 36
Holding 18 22
Coil Family
Type Size
All S3
21 1/2 28 10 200 140 200 140 200 140 — — 180 Nitrile 8 9 S212GF02N1JJ5
1 1/2 28 10 — — — — — — 100*100* 366 Teflon 8 9 S212GH02T1JJ5
IN °F
Normally Open
Valve Selection List
P P
Energized
P
De-Energized
Orif
ice
Siz
e
Pip
e S
ize
Min
imum
AC DC AC DC AC DC AC DC AC DC
Sea
l Mat
eria
l
Max
F
luid
Tem
p.
CvNPT
Air/Gas Water Light Oil Steam*
Operating Pressure Differential (psi)Maximum
Power Consumption
(Watts)
Model Code
120V/60HZ — 110V/50HZShown
Stainless Steel BodyType 316
( )
* Class H Coil Recommended for Steam and Other High Temperature Applications
![Page 107: GC Valves—S21 Series Overview€¦ · GC Valves—S21 Series Overview Specifications in this guide: • 2-way piloted diaphragm valves • Available in normally closed and normally](https://reader034.fdocuments.in/reader034/viewer/2022050423/5f92550cc433bf564a129ecb/html5/thumbnails/107.jpg)
Page 107