Gas & SteamTurbine Generators
4-Pole Synchronous Generators
7/23/2019 Gas Steam Turbine
http://slidepdf.com/reader/full/gas-steam-turbine 2/2
2075 Howard Drive WestNorth Mankato, MN 56003Phone: 507-625-4011
katoengineering.com
KATO™ generators operateefciently, reliably and canbe designed your way.
High efficiency = lower operating costs
Core losses, friction and windage account for efciency
losses in alternators. Kato Engineering uses a high-grade
magnetic steel with optimum design to minimize hysteresisand eddy currents losses in the core. An experienced
engineering staff, using the latest analysis tools, ensures
that losses due to friction and windage are kept at a low
level. All of this increases efciency to lower turbine genset
operating costs and increase package return.
High reliability = lower maintenance costs and
reduced downtime
Both mechanically and electrically, Kato Engineering
alternators are designed for long, trouble-free use.
Reducing vibration is a key way to lessen part wear,increasing generator reliability. Kato machines use
extremely stiff construction and sleeve bearings to
meet low vibration requirements. Sophisticated test
equipment and state-of-the industry seismic test bases
verify low vibration requirements are met or exceeded.
Sleeve bearings along with a circulating oil system also
boost reliability and ease of maintenance.
Preventing winding failure is vital to a long generator
life. Kato Engineering’s insulation system is second to
none. Mica turn-taped magnet wire in Kato generators
provides nearly twice the instantaneous surge capacityas glass-covered magnet wire to prevent shorted or
grounded windings. A global vacuum-pressure epoxy
system also protects against premature winding failure
caused by harsh environments. Kato Engineering has
dedicated engineers and testing to ensure the highest
quality of its winding and insulation system.
BENEFITS AND FEATURES
Output Range: 1,000 - 25,000 KW
Voltage: 400V (up to 5200Amps) – 15,000 Volts
Speed: 1500-1800RPM
Standard Power Factor: 0.8 lagging to 0.95 leading
Special Power Factor: Upon Request
Frequency: 50/60hz
Enclosures: Up to IP56, ODP, TEWAC,TEAAC, WPI, WPII, DIDO
Insulation: Class H epoxy VPI insulation system
Excitation: Brushless Excitation with PMG
STANDARDS AND CERTIFICATIONS:
NEMA/IEEE
IEC
Marine Agencies
API 546
IECEx/ATEX
Class1 div2
CSA
GOST-R
ISO 9001
10/2013 Gas-Steam-Turbine_L_KE