G4MICE Analysis of KEK Test Beam

35
1 G4MICE Analysis of KEK Test Beam Aron Fish Malcolm Ellis CM15 10th June 2006

description

G4MICE Analysis of KEK Test Beam. Aron Fish Malcolm Ellis CM15 10th June 2006. Contents. KEK Test Beam Set Up KEK Visualisation (MICEModel) G4MICE Status Data set TOF Set Up TOF Analysis Sci-Fi Tracker Prototype Sci-Fi Tracker Analysis Summary & Next Steps. KEK Test Beam Set Up. - PowerPoint PPT Presentation

Transcript of G4MICE Analysis of KEK Test Beam

Page 1: G4MICE Analysis of  KEK Test Beam

11

G4MICE Analysis of

KEK Test Beam

G4MICE Analysis of

KEK Test BeamAron Fish

Malcolm EllisCM15

10th June 2006

Page 2: G4MICE Analysis of  KEK Test Beam

22

ContentsContents

• KEK Test Beam Set Up• KEK Visualisation (MICEModel)• G4MICE Status• Data set• TOF Set Up• TOF Analysis• Sci-Fi Tracker Prototype• Sci-Fi Tracker Analysis• Summary & Next Steps

• KEK Test Beam Set Up• KEK Visualisation (MICEModel)• G4MICE Status• Data set• TOF Set Up• TOF Analysis• Sci-Fi Tracker Prototype• Sci-Fi Tracker Analysis• Summary & Next Steps

Page 3: G4MICE Analysis of  KEK Test Beam

33

KEK Test Beam Set UpKEK Test Beam Set Up

Purpose: Test performance of Tracker prototype in 1-Tesla magnetic field.

Page 4: G4MICE Analysis of  KEK Test Beam

44

MICEModel work in G4MICE

MICEModel work in G4MICE

• The MICEModel in G4MICE is used to represent any stage of MICE in any level of detail.

• Representations of the model are produced for specific purposes (Simulation, Reconstruction, Visualisation…).

• I will just mention the code and files implemented for the KEK Test Beam.

• The Model allows us to have the same geometry for the Reconstruction of Data and Geant4 Simulation, so that they can be compared.

• Configuration files have also been implemented, which list the material, location and orientation etc. of each module in the MICEModel (TOF, SciFi…) with respect to the other modules.

• Configuration files have now been implemented including all the MICEModules (Detectors, Magnets, AFCs…) by Ben and Mike + others for all 6 stages of MICE situated in the Hall at RAL. M. Ellis will talk about this more in the software summary talk tomorrow.

• The MICEModel in G4MICE is used to represent any stage of MICE in any level of detail.

• Representations of the model are produced for specific purposes (Simulation, Reconstruction, Visualisation…).

• I will just mention the code and files implemented for the KEK Test Beam.

• The Model allows us to have the same geometry for the Reconstruction of Data and Geant4 Simulation, so that they can be compared.

• Configuration files have also been implemented, which list the material, location and orientation etc. of each module in the MICEModel (TOF, SciFi…) with respect to the other modules.

• Configuration files have now been implemented including all the MICEModules (Detectors, Magnets, AFCs…) by Ben and Mike + others for all 6 stages of MICE situated in the Hall at RAL. M. Ellis will talk about this more in the software summary talk tomorrow.

Page 5: G4MICE Analysis of  KEK Test Beam

55

MICEModel Set Up of KEK Test Beam

MICEModel Set Up of KEK Test Beam

T1 & R1 Counters

ACC

Pb Diffuser

TOF Hodoscope(Blue & Green Slabs)

Solenoid (White)

Page 6: G4MICE Analysis of  KEK Test Beam

66

MICEModel Set Up of KEK Test Beam

MICEModel Set Up of KEK Test Beam

T1 CounterR1 Counter

ACC

Pb Diffuser

Page 7: G4MICE Analysis of  KEK Test Beam

77

MICEModel Set Up of KEK Test Beam

MICEModel Set Up of KEK Test Beam

Page 8: G4MICE Analysis of  KEK Test Beam

88

MICEModel Set Up of KEK Test Beam

MICEModel Set Up of KEK Test Beam

Page 9: G4MICE Analysis of  KEK Test Beam

99

MICEModel Set Up of KEK Test Beam

MICEModel Set Up of KEK Test Beam

Page 10: G4MICE Analysis of  KEK Test Beam

1010

G4MICE StatusG4MICE Status• The TOF Decoding, Cabling & calibration files & code have

now been written and used in G4MICE.• Atsushi’s time walk corrections have been used and

implemented into G4MICE. • The TOF Reconstruction code has now been produced

including “TofSlabHits” & ”TofSpacePoints”.• VLPC decoding used is that from Osaka (jp map 12).• VLPC calibration used is that made by Malcolm in

November 2005.• Common Mode Noise algorithm updated (use similar

technique to that described by Hideyuki).• Clustering algorithm unchanged (2.0 PE total light in a

cluster, neighbouring hits are summed).• Space point code now takes into account arbitrary

rotations and misalignments (no longer requires trackers to be perpendicular to the Z axis!).

• Track reconstruction used for this analysis not final one.

• The TOF Decoding, Cabling & calibration files & code have now been written and used in G4MICE.

• Atsushi’s time walk corrections have been used and implemented into G4MICE.

• The TOF Reconstruction code has now been produced including “TofSlabHits” & ”TofSpacePoints”.

• VLPC decoding used is that from Osaka (jp map 12).• VLPC calibration used is that made by Malcolm in

November 2005.• Common Mode Noise algorithm updated (use similar

technique to that described by Hideyuki).• Clustering algorithm unchanged (2.0 PE total light in a

cluster, neighbouring hits are summed).• Space point code now takes into account arbitrary

rotations and misalignments (no longer requires trackers to be perpendicular to the Z axis!).

• Track reconstruction used for this analysis not final one.

Page 11: G4MICE Analysis of  KEK Test Beam

1111

Low Momentum Data Set

Low Momentum Data Set

• 250 MeV/c• B = 0, = 0: Runs 1426 & 1427• B = 1, = 3: Runs 1360 & 1367

• 325 MeV/c• B = 1, = 3: Runs 1376, 1381 & 1382• B = 1, = 6: Run 1342

• 250 MeV/c• B = 0, = 0: Runs 1426 & 1427• B = 1, = 3: Runs 1360 & 1367

• 325 MeV/c• B = 1, = 3: Runs 1376, 1381 & 1382• B = 1, = 6: Run 1342

Page 12: G4MICE Analysis of  KEK Test Beam

1212

High Momentum Data Set

High Momentum Data Set

• 3 GeV/c• B = 0, = 0: Runs 1257, 1258 & 1272• B = 0, = 6: Runs 1291, 1292, 1293, 1294,

1297, 1300, 1302, 1303, 1304, 1306, 1307, 1309 & 1311

• B = 1, = 6: Runs 1315 & 1317

• Total 396762 triggers (98408 low, 298354 high)• 62573 pass cuts (L1A and tracking)

• 10781 low• 51792 high

• 3 GeV/c• B = 0, = 0: Runs 1257, 1258 & 1272• B = 0, = 6: Runs 1291, 1292, 1293, 1294,

1297, 1300, 1302, 1303, 1304, 1306, 1307, 1309 & 1311

• B = 1, = 6: Runs 1315 & 1317

• Total 396762 triggers (98408 low, 298354 high)• 62573 pass cuts (L1A and tracking)

• 10781 low• 51792 high

Page 13: G4MICE Analysis of  KEK Test Beam

1313

TOF Set Up (KEK)TOF Set Up (KEK)PMT

Light guide

Scintillator

5 X 5 Hodoscope

Page 14: G4MICE Analysis of  KEK Test Beam

1414

TOF Analysis 1TOF Analysis 1

BlackBlack: 3 GeV/cRedRed: 325 MeV/cBlueBlue: 250 MeV/c

Page 15: G4MICE Analysis of  KEK Test Beam

1515

TOF SelectionTOF Selection

“High P”

“Low P Electrons”

“Low P Muons”

Page 16: G4MICE Analysis of  KEK Test Beam

1616

L1A SelectionL1A Selection

Page 17: G4MICE Analysis of  KEK Test Beam

1717

Sci-Fi PrototypeSci-Fi PrototypePrototype Tracker consisted of 4 stations.Stations B & D - 3 ViewsStations A & C - 2 ViewsReadout - VLPCs, AFEII, Cryostat.

X View V View W View

Station D 2,500 ppm

2,500 ppm

5,000 ppm

Station A mixture 5,000 ppm

Station C 5,000 ppm

5,000 ppm

Station B 5,000 ppm

2,500 ppm

3,500 ppm

Page 18: G4MICE Analysis of  KEK Test Beam

1818

VLPC HitsVLPC Hits• Common

Mode Noise algorithm now similar to that used by Osaka group.

• Pedestals and gains those presented on 18th November 2005.

• Common Mode Noise algorithm now similar to that used by Osaka group.

• Pedestals and gains those presented on 18th November 2005.

Page 19: G4MICE Analysis of  KEK Test Beam

1919

Sci-Fi Space PointsSci-Fi Space Points

Page 20: G4MICE Analysis of  KEK Test Beam

2020

SciFi Space PointsSciFi Space Points

Page 21: G4MICE Analysis of  KEK Test Beam

2121

Page 22: G4MICE Analysis of  KEK Test Beam

2222

Page 23: G4MICE Analysis of  KEK Test Beam

2323

Page 24: G4MICE Analysis of  KEK Test Beam

2424

Page 25: G4MICE Analysis of  KEK Test Beam

2525

Page 26: G4MICE Analysis of  KEK Test Beam

2626

Page 27: G4MICE Analysis of  KEK Test Beam

2727

Page 28: G4MICE Analysis of  KEK Test Beam

2828

Page 29: G4MICE Analysis of  KEK Test Beam

2929

Page 30: G4MICE Analysis of  KEK Test Beam

3030

Page 31: G4MICE Analysis of  KEK Test Beam

3131

Page 32: G4MICE Analysis of  KEK Test Beam

3232

Page 33: G4MICE Analysis of  KEK Test Beam

3333

Sci-Fi Summary 1/2Sci-Fi Summary 1/2Low mom.

Low mom.

eHigh mom.

Station A Plane V

9.51 8.14 8.00

Station A Plane X

9.98 8.12 7.98

Station B Plane V

9.13 8.21 7.22

Station B Plane X

8.37 7.31 7.21

Station B Plane W

9.74 8.73 8.58

Station C Plane X

9.74 9.41 9.18

Station C Plane W

11.0 8.76 8.86

Station D Plane V

5.96 4.48 3.57

Station D Plane X

5.98 5.15 4.49

Station D Plane W

5.02 5.28 4.28

Page 34: G4MICE Analysis of  KEK Test Beam

3434

SciFi Summary 2/2SciFi Summary 2/2

Low mom.

Low mom. e

High mom.

Cosmic Rays

Old 2500

9.13 8.21 7.00 10.6

Old 3500

9.74 8.73 8.58 10.3

Old 5000

9.53 8.33 8.16 8.96

New 2500

5.98 No Plot 4.91

New 5000

5.92 5.28 4.76

Page 35: G4MICE Analysis of  KEK Test Beam

3535

Summary & Next Steps…

Summary & Next Steps…

• Implement correct digitisation of TOF in DetResp.

• Update Persist package to take into account modified TOF and SciFi classes (new methods).

• Test each stage of the Reconstruction (hits, clusters, points, tracks, matching) using the Geant4 simulation of test beam.

• Test Reconstruction of real data (TOF & SciFi).

• Implement correct digitisation of TOF in DetResp.

• Update Persist package to take into account modified TOF and SciFi classes (new methods).

• Test each stage of the Reconstruction (hits, clusters, points, tracks, matching) using the Geant4 simulation of test beam.

• Test Reconstruction of real data (TOF & SciFi).