fva by appu.pptx

22

Transcript of fva by appu.pptx

Page 1: fva by appu.pptx

7/27/2019 fva by appu.pptx

http://slidepdf.com/reader/full/fva-by-appupptx 1/22

Page 2: fva by appu.pptx

7/27/2019 fva by appu.pptx

http://slidepdf.com/reader/full/fva-by-appupptx 2/22

“ A human being is a single beingunique and unrepeatable” -ELEEN CADDY 

Page 3: fva by appu.pptx

7/27/2019 fva by appu.pptx

http://slidepdf.com/reader/full/fva-by-appupptx 3/22

 Automated system and computers simplifiedour life

Need to provide security to the systems

Use of passwords are the preferred methodSharing and theft are common

Later introduction to the biometrics

Page 4: fva by appu.pptx

7/27/2019 fva by appu.pptx

http://slidepdf.com/reader/full/fva-by-appupptx 4/22

Measurement of biological characteristicsIdentity verification

 Veins , fingerprints , iris pattern , face pattern

 voice patternFundamental properties of ideal biometrics:

Security:-resistance to forgery ,

accuracy practicality:- speed , cost , size ,enrolment , convenience

Page 5: fva by appu.pptx

7/27/2019 fva by appu.pptx

http://slidepdf.com/reader/full/fva-by-appupptx 5/22

 

Page 6: fva by appu.pptx

7/27/2019 fva by appu.pptx

http://slidepdf.com/reader/full/fva-by-appupptx 6/22

FINGERVEIN

RECOGNITION

 A new biometric methodUtilizes finger vein patternUnique for each finger and for eachperson

Falsification extremely difficult

Page 7: fva by appu.pptx

7/27/2019 fva by appu.pptx

http://slidepdf.com/reader/full/fva-by-appupptx 7/22

Meets anti-forgery by internal biometric Accuracy requirement is met

Offers great convenience-insensitive to

extraneous factors like dirt or greaseEffective as finger vein pattern remains samethrough adult years

 Very fast

No enrolment problems

Cost effectiveness is excellent

Page 8: fva by appu.pptx

7/27/2019 fva by appu.pptx

http://slidepdf.com/reader/full/fva-by-appupptx 8/22

 Works by shininginvisible infrared light via finger

Hemoglobin in blood

absorbs infrared lightResult is image of unique pattern veins

It is captured by sensor

Page 9: fva by appu.pptx

7/27/2019 fva by appu.pptx

http://slidepdf.com/reader/full/fva-by-appupptx 9/22

Capture of finger vein pattern:

# sensor captures finger vein image andpasses it to CPU memory 

Normalization of image:

# normalized to accommodate geometricchanges or angle of finger

Feature pattern extraction from image:

# distinctive features of finger vein patternare extracted

Page 10: fva by appu.pptx

7/27/2019 fva by appu.pptx

http://slidepdf.com/reader/full/fva-by-appupptx 10/22

# for eliminating variations in captured data.# result is standard finger vein template.

Pattern matching and outcome decision.

# captured finger vein template is matchedagainst previously stored template.

# if close match found ,user is authenticated.

Page 11: fva by appu.pptx

7/27/2019 fva by appu.pptx

http://slidepdf.com/reader/full/fva-by-appupptx 11/22

Page 12: fva by appu.pptx

7/27/2019 fva by appu.pptx

http://slidepdf.com/reader/full/fva-by-appupptx 12/22

FINGERVEIN :

Uses transmitted infrared rays

High contrast images

Capture of deeper veinpatterns

High tolerance to noise

Easier to matching algorithm

Median recognition attempt

duration is 1.23sMedian enrolment duration is33.3s

Finger vein devices are of 

small size

PALMVEIN :

Uses reflected infrared rays

Reduced image contrast

Penetrates only shallow way under the skin

Susceptible to noise (dirt,roughness of skin)

Challenge to matching

algorithmMedian recognition attemptduration is 2.13s

Median enrolment duration is61.7

Palm vein devices are bulkier

Page 13: fva by appu.pptx

7/27/2019 fva by appu.pptx

http://slidepdf.com/reader/full/fva-by-appupptx 13/22

Page 14: fva by appu.pptx

7/27/2019 fva by appu.pptx

http://slidepdf.com/reader/full/fva-by-appupptx 14/22

Page 15: fva by appu.pptx

7/27/2019 fva by appu.pptx

http://slidepdf.com/reader/full/fva-by-appupptx 15/22

PC login security Mobile phone login security 

Door entry control

Bank security 

Page 16: fva by appu.pptx

7/27/2019 fva by appu.pptx

http://slidepdf.com/reader/full/fva-by-appupptx 16/22

Page 17: fva by appu.pptx

7/27/2019 fva by appu.pptx

http://slidepdf.com/reader/full/fva-by-appupptx 17/22

High accuracy rateFast authentication speed

Unique and constant

No enrolment problemsEase of feature extraction

Resistant to criminal tapering

Falsification is difficult

Page 18: fva by appu.pptx

7/27/2019 fva by appu.pptx

http://slidepdf.com/reader/full/fva-by-appupptx 18/22

Only be used if the person is living.

Page 19: fva by appu.pptx

7/27/2019 fva by appu.pptx

http://slidepdf.com/reader/full/fva-by-appupptx 19/22

Finger printing : exterior to body-falsificationeasy-sweaty finger prints cannot beregistered.

Iris scanning: direct application of light intothe eyes, cause irritation.

Face and voice recognition: impersonation iseasy – accuracy rate limited-low security.

Page 20: fva by appu.pptx

7/27/2019 fva by appu.pptx

http://slidepdf.com/reader/full/fva-by-appupptx 20/22

Finger vein has inherent properties toperform in areas that matters both security and practicality.

Proven with extensive applications in Japan.Quantitatively and qualitatively finger veinrecognition superiors all other methods.

Its potential of versatile reliable means of identification has positive implication inindustry ,commerce ,government and lawenforcement agencies.

Page 21: fva by appu.pptx

7/27/2019 fva by appu.pptx

http://slidepdf.com/reader/full/fva-by-appupptx 21/22

http://www.hitachi-eu.com/veinid  www.ieee.com 

 www.wikipedia.com 

Page 22: fva by appu.pptx

7/27/2019 fva by appu.pptx

http://slidepdf.com/reader/full/fva-by-appupptx 22/22