Furnacesalso called Fired Heaters
Julie King
Originally prepared by Todd King. I edited for use in CM4120.
![Page 2: Furnaces also called Fired Heaters Julie King Originally prepared by Todd King. I edited for use in CM4120.](https://reader035.fdocuments.in/reader035/viewer/2022062511/5519ccc6550346443e8b48f3/html5/thumbnails/2.jpg)
Fired Heaters-What they look like
![Page 3: Furnaces also called Fired Heaters Julie King Originally prepared by Todd King. I edited for use in CM4120.](https://reader035.fdocuments.in/reader035/viewer/2022062511/5519ccc6550346443e8b48f3/html5/thumbnails/3.jpg)
Fired Heaters
Often in a large chemical plant or refinery, there will be 50 furnaces.
Often you will preheat a feed to get it up to the temperature needed for a reaction in a reactor (i.e., for an endothermic reaction).
Furnaces are often used to preheat the feed before it goes into the reactor.
![Page 4: Furnaces also called Fired Heaters Julie King Originally prepared by Todd King. I edited for use in CM4120.](https://reader035.fdocuments.in/reader035/viewer/2022062511/5519ccc6550346443e8b48f3/html5/thumbnails/4.jpg)
Direct Fired Furnaces
We will focus on direct fired furnaces.– Have air/fuel (fuel oil or natural gas)
/combustion gases in the “firebox” and this heats the process stream such as heavy hydrocarbons (oils in a refinery) etc.
– The process stream being heated (like a process gas oil) is inside tubes.
– The cooler process stream enters the top of the furnace (convection section) and exits near the bottom (radiant section).
![Page 5: Furnaces also called Fired Heaters Julie King Originally prepared by Todd King. I edited for use in CM4120.](https://reader035.fdocuments.in/reader035/viewer/2022062511/5519ccc6550346443e8b48f3/html5/thumbnails/5.jpg)
Fired Heaters
![Page 6: Furnaces also called Fired Heaters Julie King Originally prepared by Todd King. I edited for use in CM4120.](https://reader035.fdocuments.in/reader035/viewer/2022062511/5519ccc6550346443e8b48f3/html5/thumbnails/6.jpg)
Burner Sketch
-Burners located“under’ thefurnace.-Air/fuel mixes-Get combustion-Atomizing steamused to get betterair/fuel mixing
![Page 7: Furnaces also called Fired Heaters Julie King Originally prepared by Todd King. I edited for use in CM4120.](https://reader035.fdocuments.in/reader035/viewer/2022062511/5519ccc6550346443e8b48f3/html5/thumbnails/7.jpg)
Combustion
Rapid chemical reaction that occurs when the proper amounts of a fuel and oxygen are combined with an ignition source to release heat and light. CO2 and H2O are the combustion products for a complete combustion reaction.
Different fuels release different amounts of heat (energy) as they are burned.
![Page 8: Furnaces also called Fired Heaters Julie King Originally prepared by Todd King. I edited for use in CM4120.](https://reader035.fdocuments.in/reader035/viewer/2022062511/5519ccc6550346443e8b48f3/html5/thumbnails/8.jpg)
Fired Heater
![Page 9: Furnaces also called Fired Heaters Julie King Originally prepared by Todd King. I edited for use in CM4120.](https://reader035.fdocuments.in/reader035/viewer/2022062511/5519ccc6550346443e8b48f3/html5/thumbnails/9.jpg)
Components of a Furnace
Fire box Radiant Tubes Convection Tubes Damper and Stack Refractory Lining Burners and Air Registers (lets air in by
burners)
![Page 10: Furnaces also called Fired Heaters Julie King Originally prepared by Todd King. I edited for use in CM4120.](https://reader035.fdocuments.in/reader035/viewer/2022062511/5519ccc6550346443e8b48f3/html5/thumbnails/10.jpg)
Fire Box and Refractory Layer
This section contains the burners (under it) the open flames, and combustion gases.
Fire box is lined with refractory brick (usually white/tan in color, lightweight, chalk-like, ceramic material) lining that can handle high temperatures and reflects heat back into the furnace.
![Page 11: Furnaces also called Fired Heaters Julie King Originally prepared by Todd King. I edited for use in CM4120.](https://reader035.fdocuments.in/reader035/viewer/2022062511/5519ccc6550346443e8b48f3/html5/thumbnails/11.jpg)
Fire Box and Refractory Layer
Refractory layer include a brick layer and stainless steel rods (sometimes a wire mesh) for the brick to attach to
“Peep” holes so the operator/engineer can view the firebox ‘flame’, get a temperature reading, etc.
Fire box temperature typically 1,800 oF.
![Page 12: Furnaces also called Fired Heaters Julie King Originally prepared by Todd King. I edited for use in CM4120.](https://reader035.fdocuments.in/reader035/viewer/2022062511/5519ccc6550346443e8b48f3/html5/thumbnails/12.jpg)
Radiant Tubes
Radiant tubes (process stream inside them, i.e. oil, etc) are along the walls in the fire box. They receive direct heat from the flames (burners). This section of tubes sees higher temperatures and has a faster accumulation of coke (carbon – like when you BBQ on your grill) deposits on inside of the tubes.
Radiant heat transfer typically accounts for 65% of the total heat absorbed by the process stream (oil, etc.).
![Page 13: Furnaces also called Fired Heaters Julie King Originally prepared by Todd King. I edited for use in CM4120.](https://reader035.fdocuments.in/reader035/viewer/2022062511/5519ccc6550346443e8b48f3/html5/thumbnails/13.jpg)
Convection Tubes
Convection tubes (process fluid inside them, i.e. oil, etc.) are in the roof of the furnace so NOT in contact with the direct flames in the fire box.
The hot combustion gases transfer heat thru the metal tubes (often finned tubes to increase efficiency) and into the process fluid.
Convective heat transfer typically accounts for 35% of the total heat absorbed by the process stream (oil, etc.).
![Page 14: Furnaces also called Fired Heaters Julie King Originally prepared by Todd King. I edited for use in CM4120.](https://reader035.fdocuments.in/reader035/viewer/2022062511/5519ccc6550346443e8b48f3/html5/thumbnails/14.jpg)
Damper and Stack
Warm air and combustion gases leave the furnace thru the stack and enter the atmosphere.
This natural draft (like your chimney in your house that carries the combustion gases up) creates a lower pressure inside the furnace.
Draft = atm pressure – pressure inside fired heater Typically 0.05 inches water (vaccum) by the
stack damper
![Page 15: Furnaces also called Fired Heaters Julie King Originally prepared by Todd King. I edited for use in CM4120.](https://reader035.fdocuments.in/reader035/viewer/2022062511/5519ccc6550346443e8b48f3/html5/thumbnails/15.jpg)
Draft Profile
![Page 16: Furnaces also called Fired Heaters Julie King Originally prepared by Todd King. I edited for use in CM4120.](https://reader035.fdocuments.in/reader035/viewer/2022062511/5519ccc6550346443e8b48f3/html5/thumbnails/16.jpg)
Damper
Damper is often 10 ft up in the stack and allows the adjustment of the stack draft.
Damper also allows how much air gets into the furnace. Open the damper, and more air comes in. Use the damper to control the excess O2 in the furnace.
Typically want about 2 mol% excess O2 or else you waste energy (just send too much hot air out the stack that you did not need to heat).
![Page 17: Furnaces also called Fired Heaters Julie King Originally prepared by Todd King. I edited for use in CM4120.](https://reader035.fdocuments.in/reader035/viewer/2022062511/5519ccc6550346443e8b48f3/html5/thumbnails/17.jpg)
Furnace Controls
![Page 18: Furnaces also called Fired Heaters Julie King Originally prepared by Todd King. I edited for use in CM4120.](https://reader035.fdocuments.in/reader035/viewer/2022062511/5519ccc6550346443e8b48f3/html5/thumbnails/18.jpg)
Furnace Types of Furnace Drafts
Natural Draft: draft is induced by buoyancy forces as the hot air rises thru the stack and creates a vacuum inside the fire box. Pressure in fire box < atm pressure
Forced Draft : fans are used to force air into the burners (below the fire box)
![Page 19: Furnaces also called Fired Heaters Julie King Originally prepared by Todd King. I edited for use in CM4120.](https://reader035.fdocuments.in/reader035/viewer/2022062511/5519ccc6550346443e8b48f3/html5/thumbnails/19.jpg)
Furnace Types of Furnace Drafts
Induced Draft: a fan is put in the stack that enhances the low pressure in the fire box.
Balanced Draft : uses 2 fans
– 1 fan pulls air out the stack
– 1 fan forces air into the burners
![Page 20: Furnaces also called Fired Heaters Julie King Originally prepared by Todd King. I edited for use in CM4120.](https://reader035.fdocuments.in/reader035/viewer/2022062511/5519ccc6550346443e8b48f3/html5/thumbnails/20.jpg)
Natural and Forced Draft
![Page 21: Furnaces also called Fired Heaters Julie King Originally prepared by Todd King. I edited for use in CM4120.](https://reader035.fdocuments.in/reader035/viewer/2022062511/5519ccc6550346443e8b48f3/html5/thumbnails/21.jpg)
Induced and Balanced Draft
![Page 22: Furnaces also called Fired Heaters Julie King Originally prepared by Todd King. I edited for use in CM4120.](https://reader035.fdocuments.in/reader035/viewer/2022062511/5519ccc6550346443e8b48f3/html5/thumbnails/22.jpg)
Common Furnace Problems
Flame Impingement: flames from the burner touching a tube .
– This weakens the metal tube and causes coke (carbon) to form inside the tube where the process fluid is
– Solve by reducing the fuel supply to the affected burner.
![Page 23: Furnaces also called Fired Heaters Julie King Originally prepared by Todd King. I edited for use in CM4120.](https://reader035.fdocuments.in/reader035/viewer/2022062511/5519ccc6550346443e8b48f3/html5/thumbnails/23.jpg)
Common Furnace Problems
Coke Formation
– Coking always occurs inside the process fluid tubes (typically the radiant tube section where it is hottest) in a furnace.
– Remove coke by shutting down the furnace (typically once/3 yrs) and injection superheated steam to remove the coke.
![Page 24: Furnaces also called Fired Heaters Julie King Originally prepared by Todd King. I edited for use in CM4120.](https://reader035.fdocuments.in/reader035/viewer/2022062511/5519ccc6550346443e8b48f3/html5/thumbnails/24.jpg)
Common Furnace Problems
Replace Refractory
– Refractory in the fire box becomes brittle and start to fall off over time at high temperatures.
– Solve by shutting down the furnace (typically once/3 yrs) and removing old refractory and installing new refractory.
![Page 25: Furnaces also called Fired Heaters Julie King Originally prepared by Todd King. I edited for use in CM4120.](https://reader035.fdocuments.in/reader035/viewer/2022062511/5519ccc6550346443e8b48f3/html5/thumbnails/25.jpg)
Common Furnace Problems
Fuel Composition Changes– The fuel composition of the fuel oil or natural
gas can change.– The more heat a fuel produces during
combustion, the more air is needed.– Your process control programs can help you
here. Control the % excess O2 (open/close damper), allow more or less fuel into burner, etc.).
![Page 26: Furnaces also called Fired Heaters Julie King Originally prepared by Todd King. I edited for use in CM4120.](https://reader035.fdocuments.in/reader035/viewer/2022062511/5519ccc6550346443e8b48f3/html5/thumbnails/26.jpg)
Common Furnace Problems
Process Fluid Feed Pump Failure
– The furnace will get too hot, causing coking and damaging the equipment (too hot for the furnace materials).
– Try to restart the feed pump or start the back up process feed pump FAST!
– Then isolate (block off) the primary feed pump and get it fixed ASAP.
![Page 27: Furnaces also called Fired Heaters Julie King Originally prepared by Todd King. I edited for use in CM4120.](https://reader035.fdocuments.in/reader035/viewer/2022062511/5519ccc6550346443e8b48f3/html5/thumbnails/27.jpg)
Common Furnace Problems
Flameout
– Occurs when the burner flame goes out with the fuel still being pumped into it.
– Now we have unburned fuel inside the furnace.
– Often happens when there is not enough air in the burner.
– Solution: shutdown the furnace. Stop fuel into the burner/furnace. This is a dangerous situation.
![Page 28: Furnaces also called Fired Heaters Julie King Originally prepared by Todd King. I edited for use in CM4120.](https://reader035.fdocuments.in/reader035/viewer/2022062511/5519ccc6550346443e8b48f3/html5/thumbnails/28.jpg)
References
W. L. Luyben, B. D. Tyrus, M. L. Luyben, “Plantwide Process Control”, McGraw Hill, NY, 1999.
C. E. Thomas, “The Process Technololgy Handbook”, Uhai Publishing, Berne, NY, 1997.