Furnace Ozonator
-
Upload
gunars-rozite -
Category
Documents
-
view
485 -
download
2
description
Transcript of Furnace Ozonator
![Page 1: Furnace Ozonator](https://reader034.fdocuments.in/reader034/viewer/2022051411/547a0db0b4af9faf158b49ad/html5/thumbnails/1.jpg)
Furnace OzonatorIs it worthof effort?
Ozonators where used mainly in mid range to large boiling houses and heat factories.
![Page 2: Furnace Ozonator](https://reader034.fdocuments.in/reader034/viewer/2022051411/547a0db0b4af9faf158b49ad/html5/thumbnails/2.jpg)
Typical minuses of home furnaces:Air intake is taken from room and moves heat awayPoor Fireplace construction limit max temp < 650 C;Water heater cannot be disassembled for maintenaceExhaust releases hot gass to chimney
![Page 3: Furnace Ozonator](https://reader034.fdocuments.in/reader034/viewer/2022051411/547a0db0b4af9faf158b49ad/html5/thumbnails/3.jpg)
30 x 30 x 15 cm pack would cost about 350 Eurtogether with HV electronics
![Page 4: Furnace Ozonator](https://reader034.fdocuments.in/reader034/viewer/2022051411/547a0db0b4af9faf158b49ad/html5/thumbnails/4.jpg)
and produce following particles
![Page 5: Furnace Ozonator](https://reader034.fdocuments.in/reader034/viewer/2022051411/547a0db0b4af9faf158b49ad/html5/thumbnails/5.jpg)
![Page 6: Furnace Ozonator](https://reader034.fdocuments.in/reader034/viewer/2022051411/547a0db0b4af9faf158b49ad/html5/thumbnails/6.jpg)
The First root of Evil
![Page 7: Furnace Ozonator](https://reader034.fdocuments.in/reader034/viewer/2022051411/547a0db0b4af9faf158b49ad/html5/thumbnails/7.jpg)
Furnace ozonator would remove
Pullutant Effect
VOCs - Volatible Organic Compounds YES ~ 50%
Mono carbon oxide CO. YES ~80%
Dioxide carbon CO2. NO
Hydrocarbons CxHy. NO
Sulpher oxide SO2. NO ~20% with steammoisturizer*
First nitric oxide NO. YES ~90%
Second nitric oxide NO2. YES ~80% with steammoisturizer*
*Feed in chimney
![Page 8: Furnace Ozonator](https://reader034.fdocuments.in/reader034/viewer/2022051411/547a0db0b4af9faf158b49ad/html5/thumbnails/8.jpg)
How much ozone we need?
![Page 9: Furnace Ozonator](https://reader034.fdocuments.in/reader034/viewer/2022051411/547a0db0b4af9faf158b49ad/html5/thumbnails/9.jpg)
Ozone impact on VOC conversion
![Page 10: Furnace Ozonator](https://reader034.fdocuments.in/reader034/viewer/2022051411/547a0db0b4af9faf158b49ad/html5/thumbnails/10.jpg)
Danish Gass authors where found that
• The reduction of NOx emission is more efficient at lower temperature (110 °C) than at higher temperature (160 °C), so ~5% (1/20) of ozone produced must be feed directly to chimney viasecond flow regulator;
• O2 is more efficient than air as ozone agent (keep oxigen cilinder).• The technique is applicable on flue gas from biomass combustion
despite the presence of compounds such as SO2 and HCl.• Reduction of NOx emissions requires approximately half as much
O3 when it is applied to the natural gas fired engine unit compared to the straw fired boiler unit.
• The higher O3 consumption on straw fired units is due to both higher flue gas temperature and larger NOx fluctuations in the flue gas compared to the gas engine unit.
![Page 11: Furnace Ozonator](https://reader034.fdocuments.in/reader034/viewer/2022051411/547a0db0b4af9faf158b49ad/html5/thumbnails/11.jpg)
REFERENCES
[1] Using Non-Thermal Plasma to control Air pollutants”, United States Environmental Protection Agency, EPA-456/R-05-001, Feb. 2005,www.epa.gov/ttn/catc/dir1/fnonthrm.pdf.
[2] Jensen T.K., Nihøj, J., Fenger L.D. (2005): Development of biomass combustion technology. 14th European Biomass Conference and Exhibition: Biomass for Energy, Industry and Climate Protection.
[3] Bindslev, H. et al. Emission reduction by means of low temperature plasma PSO project no. FU3401. Final report. Risø-l- 2380(EN). 2005.
![Page 12: Furnace Ozonator](https://reader034.fdocuments.in/reader034/viewer/2022051411/547a0db0b4af9faf158b49ad/html5/thumbnails/12.jpg)
Thank You for attention