Full Product Line Cataloque 2010 Split-type_air_conditioners

download Full Product Line Cataloque 2010 Split-type_air_conditioners

of 268

Transcript of Full Product Line Cataloque 2010 Split-type_air_conditioners

  • 8/11/2019 Full Product Line Cataloque 2010 Split-type_air_conditioners

    1/268

  • 8/11/2019 Full Product Line Cataloque 2010 Split-type_air_conditioners

    2/268

    The Mitsubishi Electric Group promotes sustainable development and is

    committed to protecting and restoring the global environment through technology,

    through all its business activities, and through the actions of its employees.

    Core Environmental Policy

    Doing Our Part to

    Create a Better Future for All...

  • 8/11/2019 Full Product Line Cataloque 2010 Split-type_air_conditioners

    3/268

    Heat pump technology inspires Mitsubishi Electric to design air conditioners

    that harmonize comfort and ecology.

    Mitsubishi Electric reflects the essence of this policy andvision in all aspects of its air conditioner business as well.

    Preventing Global Warming

    1. All models are designed for RoHS and WEEE compliance.*2. Mitsubishi Electric develops downsizing technology to reduce materials

    use.

    *WEEE and RoHS directives: The Waste Electrical and Electronic Equipment (WEEE)Directive is arecycling directive for this type of equipment, while the Restrictions of Hazardous Substances(RoHS)Directive is an EU directive restricting the use of six specified substances in electronic andelectrical devices. In the EU, it is no longer possible (from July 2006)to sell products containing anyof the six substances.

    - PUHZ-RP200/250YKA2: Volume reduction approx. 60% compared toPUHZ-RP200/250YHA

    - MUZ-HC25/25VA: Volume reduction approx. 25% compared toMUZ-HA25/35VA

    Creating a Recycling-Based Society

    In striving to heighten the eco-awareness of its employees, Mitsubishi Electric

    provides education in RoHS, WEEE and other environmental regulations, along

    with environmental education targeting second and third-year workers.

    Ensuring Harmony with Nature/

    Fostering Environmental Awareness

    1. Inverter

    2. i-see Sensor

    3. Flash Injection

    Comfort Ecology

    Faster start-up and morestable indoor temperaturethan non-inverter units.

    Fewer On/Off operationsthan with non-inverter, savingenergy.

    Monitoring the temperaturegaps between the floor andthe set temperature to preventdeficient warming.

    Optimum control of the airflow toprevent excessive compressoroperation for more efficientheating operation.

    Achieves high heatingcapacity even at lowtemperatures, plus fasterstart-up compared toconventional inverters.

    Expands the region covered byheat pump heating system.

    Mitsubishi Electric develops technologies to balance comfortand ecology, achieving greater efficiency in heat pump operation.

    Heat Pump Principle (When Heating) Refrigerant and Heat Circulation

    Outdoors

    4kWHeat absorbed

    from the air

    Indoors

    Expansion valve expandsrefrigerant to lower the temperature

    Compressor

    Expansion valve

    Evaporator Condenser

    Compressor compressesrefrigerant to raisethe temperature 1kW

    Electrical Energy Input

    5kWHeat output

    Output energy is quintupleof input energy

    4kWHeat Absorbed from the air

    5kWHeat Output

    5oC 50oC

    80oC10oC

    60oC60

    oC

    1kW

    20oC

    30oC 40

    oC

    Electrical

    Energy Input

    Electrical

    Energy Input

    Heat

  • 8/11/2019 Full Product Line Cataloque 2010 Split-type_air_conditioners

    4/2683

    CONTENTS

  • 8/11/2019 Full Product Line Cataloque 2010 Split-type_air_conditioners

    5/2684

    LINE-UP LIST

    FEATURES

    M SERIES

    S SERIES

    P SERIES

    POWERFUL HEATING SERIES

    MXZ SERIES

    OPTIONAL PARTS

    EXTERNAL DIMENSIONS

    PIPING INSTALLATION

    FEATURES & SPECIFICATIONS

    FEATURES & SPECIFICATIONS

    005-008

    009-024

    025-044

    045-050

    051-082

    083-092

    093-220

    221-226

    227-242

    243-247

    249-254

    255-266

    Air Conditioners

    AIR-TO-WATER

    LOSSNAY SYSTEM

  • 8/11/2019 Full Product Line Cataloque 2010 Split-type_air_conditioners

    6/2685

    INVERTER Models

    FIXED-SPEED Models (Heat Pump & Cooling Only)

    INVERTER Models

    M SERIES

    S SERIES

    PageModel Name1.5kW

    1-phase

    2.0kW

    1-phase

    8.0kW

    1-phase

    Page5.0kW4.2kW3.5kW2.5kW2.2kW2.0kW

    Model Name6.0kW 7.1kW 8.0kW

    SINGLE SINGLE SINGLE

    SINGLE SINGLE

    SINGLE

    SINGLE

    SINGLE

    SINGLE

    SINGLE

    SINGLE SINGLE SINGLE

    SINGLE

    6.0kW

    1-phase

    SINGLE

    7.1kW

    1-phase

    SINGLE

    LINE-UP

    Wall-mounted

    Wall-mounted

    Compactfloor

    1-waycassette

    MSZ-F Series

    MFZ Series

    MLZ Series

    MSZ-G Series

    MSZ-H Series

    H: Outdoor unit with anti-freeze heater is available.

    S: Indoor units are available in two colours; Silver or White.

    Page5.0kW4.2kW3.5kW2.5kW

    Model Name6.0kW 7.1kW 8.0kW

    1-phase1-phase1-phase1-phase1-phase1-phase 1-phase 1-phase 1-phase

    1-phase1-phase1-phase1-phase 1-phase 1-phase 1-phase

    2 x 2cassette

    Compactceiling-concealed

    SLZ Series

    SEZ Series

    MSZ-S Series

    4.2kW

    1-phase

    SINGLEH

    3.5kW

    1-phase

    SINGLE

    SINGLEH

    SINGLES

    SINGLEH

    MXZconnection

    only

    5.0kW

    1-phase

    SINGLEH

    SINGLES

    SINGLE

    NEW NEW

    NEW NEW

    MXZconnection

    only

    2.5kW

    1-phase

    SINGLE

    SINGLEH

    SINGLEH

    SINGLES

    MXZconnection

    only

    2.2kW

    1-phase

    MXZconnection

    only

    MXZconnection

    only

    MXZconnection

    only

    L L L

    L L L L L

    L: Indoor units are available in two types; with wired remote controller or with wireless remote controller.

    MS(H)-G Series

    27

    31

    31

    33

    35

    41

    43

    39 40

    39 40

    47

    49

  • 8/11/2019 Full Product Line Cataloque 2010 Split-type_air_conditioners

    7/2686

    INVERTER Models

    INVERTER Models

    MXZ SERIES

    POWERFUL HEATINGSERIES

    Page

    Page

    12.5kW10.0kW7.1kW5.0kW3.5kW2.5kW

    3-phase1- & 3-phase1-phase1-phase1-phase1-phase

    14.0kW

    10.0kW

    8.0kW

    7.1kW

    5.4kW

    5.2kW

    4.0kW

    3.0kW

    Model Name

    Wall-mountedCapacity ClassModel Name

    ZUBADAN

    4-way cassette

    PLA Series

    MSZ-FD VABH Series

    Wall-mounted

    Floor-standing Cassette

    MSZ-FD25/35/50

    MSZ-GE22/25/35/42/50/60/71

    MSZ-SF15/20

    MSZ-FD25/35/50

    MSZ-GE22/25/35/42/50/60/71

    MSZ-SF15/20

    MSZ-FD25/35/50

    MSZ-GE22/25/35/42/50/60/71

    MSZ-SF15/20

    MSZ-FD25/35/50

    MSZ-GE22/25/35/42/50/60

    MSZ-SF15/20

    MSZ-FD25/35/50

    MSZ-GE22/25/35/42/50

    MSZ-SF15/20

    MSZ-FD25/35

    MSZ-GE22/25/35

    MSZ-SF15/20

    MSZ-FD25/35

    MSZ-GE22/25/35MSZ-SF15/20

    MSZ-FD25

    MSZ-GE22/25

    MSZ-SF15/20

    up to 4 indoor unit

    MXZ-4B80VA

    up to 4 indoor unit

    MXZ-4B71VA

    up to 3 indoor unit

    MXZ-3B54VA

    up to 2 indoor unit

    MXZ-2B52VA

    up to 2 indoor unit

    MXZ-2B40VA

    up to 2 indoor unit

    MXZ-2B30VA

    up to 8 indoor unit

    MXZ-8A140VA

    up to 5 indoor unit

    MXZ-5B100VA

    MFZ-KA25/35/50

    MLZ-KA25/35/50

    SLZ-KA25/35/50

    PLA-RP35/50/60/71

    MFZ-KA25/35/50MLZ-KA25/35/50

    SLZ-KA25/35/50

    PLA-RP50/60/71

    MFZ-KA25/35/50

    MLZ-KA25/35/50

    SLZ-KA25/35/50

    PLA-RP50/60/71

    MFZ-KA25/35/50

    MLZ-KA25/35/50

    SLZ-KA25/35/50

    PLA-RP50/60

    MFZ-KA25/35/50

    MLZ-KA25/35/50

    SLZ-KA25/35/50

    PLA-RP50

    MFZ-KA25/35MLZ-KA25/35

    SLZ-KA25/35

    MFZ-KA25/35MLZ-KA25/35

    SLZ-KA25/35

    MFZ-KA25MLZ-KA25

    SLZ-KA25

    Ceiling-concealed Ceiling-suspended

    SEZ-KD25/35/50/60/71

    SEZ-KD25/35/50/60/71

    SEZ-KD25/35/50/60/71

    SEZ-KD25/35/50/60

    SEZ-KD25/35/50

    PCA-RP50/60/71

    PCA-RP50/60/71

    PCA-RP50/60

    PCA-RP50

    SEZ-KD25/35

    SEZ-KD25/35

    SEZ-KD25

    SINGLE

    TWIN

    SINGLE

    TWIN

    SINGLE

    TWIN

    H: Anti-freeze heater included as standard equipment.

    S: Indoor units are available in two colours; Silver or White.

    Model Change Icon

    New indoor & outdoor units

    New indoor unit

    New outdoor unit

    Indoor Combinations

    1 outdoor unit & 1 indoor unit

    1 outdoor unit & 2 indoor units

    1 outdoor unit & 3 indoor units

    1 outdoor unit & 4 indoor units

    SINGLE

    TWIN

    TRIPLE

    QUADRUPLE

    NEW

    NEW

    NEW

    PKA Series

    Wall-mounted SINGLE

    TWIN

    SINGLES

    SINGLES

    SINGLES

    H H H

    85

    85

    85

    87

    95

    95

    95

    95

    6.8kW

    MSZ-FD25/35/50

    MSZ-GE22/25/35/42/50/60

    MSZ-SF15/20

    up to 3 indoor unit

    MXZ-3B68VAMFZ-KA25/35/50

    MLZ-KA25/35/50

    SLZ-KA25/35/50

    PLA-RP50/60

    SEZ-KD25/35/50/60 PCA-RP50/60 95

    95

    95

    95

    95

    PEAD-JA SeriesCeiling-concealed

    SINGLE

    TWIN

    SINGLE

    TWIN

    SINGLE

    TWIN

    NEW

    NEW

    NEW

    NEW

    NEW

    NEW

    NEW

    NEW

  • 8/11/2019 Full Product Line Cataloque 2010 Split-type_air_conditioners

    8/268

  • 8/11/2019 Full Product Line Cataloque 2010 Split-type_air_conditioners

    9/268

  • 8/11/2019 Full Product Line Cataloque 2010 Split-type_air_conditioners

    10/2689

    INVERTER TECHNOLOGIESMitsubishi Electric inverters ensure superior performance including the optimum control of operation frequency. As a result,

    optimum power is applied in all heating/cooling ranges and maximum comfort is achieved while consuming minimal energy.

    Fast, comfortable operation and amazingly low running cost Thats the Mitsubishi Electric promise.

    Inverters electronically control the electrical voltage, current and frequency of electrical devices such as the compressor motor in an air conditioner.

    They receive information from sensors monitoring operating conditions, and adjust the revolution speed of the compressor, which directly

    regulates air conditioner output. Optimum control of operation frequency results in eliminating the consumption of excessive electricity and

    providing the most comfortable room environment.

    Quick & Powerful

    Increasing the compressor motor speed by controlling the operation

    frequency ensures powerful output at start-up, brings the room

    temperature to the comfort zone faster than units not equipped with

    an inverter. Hot rooms are cooled, and cold rooms are heated faster

    and more efficiently.

    Room Temperature Maintained

    The compressor motor operating frequency and the change of room

    temperature are monitored to calculate the most efficient waveform

    to maintain the room temperature in the comfort zone. This elimi-

    nates the large temperature swings common with non-inverter sys-

    tems, and guarantees a pleasant, comfortable environment.

    INVERTERS HOW THEY WORK

    Impressively low operating cost is a key advantage of inverter air

    conditioners. Weve combined advanced inverter technologies with

    cutting-edge electronics and mechanical technologies to achieve a

    synergistic effect that enables improvements in heating/cooling per-

    formance efficiency. Better performance and lower energy con-

    sumption are the result.

    ECONOMIC OPERATION

    Simple comparison of air conditioner operation control with and without inverter.

    TRUE COMFORT

    Inverter Operation Image (cooling mode)

    [Energy Efficiency Comparison]

    Non-InverterMSH-GE25VB

    Deluxe-InverterMSZ-FD25VA

    Non-InverterMSH-GE25VB

    Deluxe-InverterMSZ-FD25VA

    3.23

    5.15 5.25

    3.66

    59%UP

    43%UP

    Cooling (EER) Heating (COP)

    Temperature (C) Cooling capacity (W)

    Operation time (min)

    Rated capacity

    Setting temperatureIndoor temperature

    Measured capacity

    Point 1

    Point 1

    When room temperature is higher than the

    setting, capacity rises for the quickly adjust-

    ing the temperature to the original setting.

    When room temperature reaches the desired

    setting, capacity eases in order to maintain

    the set temperature level.

    Point 2

    Point 2

  • 8/11/2019 Full Product Line Cataloque 2010 Split-type_air_conditioners

    11/26810

    Vector-Wave Eco Inverter

    This inverter monitors the varying compressor motor frequency and

    creates the most efficient waveform for the motor speed. As the

    result, operating efficiency in all speed ranges is improved, less

    power is used and annual electricity cost is reduced.

    Inverter size has been reduced using insert-

    molding, where the circuit pattern is molded into

    the synthetic resin. To ensure quiet operation,

    soft PWM control is used to prevent the metallic

    whine associated with conventional inverters.

    Sine-wave drive soft PWMSmooth wave pattern

    MORE ADVANTAGES WITH MITSUBISHI ELECTRIC

    Grooved Piping

    High-performance grooved piping

    is used in heat exchangers to in-

    crease the heat exchange area.

    Magnetic Flux Vector Sine Wave Drive

    This drive device is actually a microprocessor that converts the com-

    pressor motors electrical current waveform from a conventional wave-

    form to a sine wave (180conductance) to achieve higher efficiency by

    raising the motor winding utilisation ratio and reducing energy loss.

    Reluctance DC Rotary Compressor

    Powerful neodymium magnets are used in the rotor of the reluc-tance DC motor. More efficient operation is realised by strong mag-

    netic and reluctance torques produced by the magnets.

    DC compressor

    motor ( rotor )

    Neodymium

    magnets

    Magnetic torque

    +Reluctance torque

    Highly Efficient DC Scroll CompressorHigher efficiency has been achieved by

    adding a frame compliance mechanism

    to the DC scroll compressor. The mecha-

    nism allows movement in the axial direc-

    tion of the frame supporting the cradle

    scroll, thereby greatly reducing leakage

    and friction loss, and ensuring extremely

    high efficiency at all speeds.

    2002JSRAE

    TECHNOLOGY AWARD

    2002JSRAE

    TECHNOLOGY AWARD

    Japan Society of

    Refrigerating and Air

    Conditioning Engineers

    Thrust gas power (minimum)

    Cradle scrollFrame

    Secondary back-pressure chamberminimises thrust friction loss

    Primary back-chamber minimisesleakage loss

    Thrust friction loss (minimum)

    Leakage loss (minimum)Fixed scroll

    Frame canmove in direction

    of axis

    Substantialreduction in leakage

    and friction loss

    Rare Earth Magnet Rotor (Compressor)

    An innovative motor with a rare earth magnet rotor is equipped in the

    compressor to ensure excellent efficiency. The rare earth magnet

    has a residual magnetic flux density

    threefold that of the previously used

    ferrite magnet.

    Rare earth magnet

    (for MSZ-FDI)

    DC Fan Motor

    A highly efficient DC motor drives the fan of the outdoor unit.

    Efficiency is much higher than an equivalent AC motor.

    Joint Lap DC Motor

    Mitsubishi Electric has developed a unique motor,

    called the Poki-Poki Motor in Japan, which is

    manufactured using a joint lapping technique.

    This innovative motor operates based on a high-density, high-magnetic force, leading to extremely

    high efficiency and reliability.

    Grooved piping

    Cross-sectional viewPipe image

    PAM

    Conventionalinverter

    Without PAMcontrol

    Merits of PAMControl

    With PAMcontrol

    Supplyvoltage

    CurrentTime

    Time

    PAM adjusts theform of the current wave so thatitbecomes close tothat ofthe supply

    voltage wave. High harmonics arereducedand 98%of the electricity isutilized.

    PAM is a technology that controls the current waveform so that it

    resembles the supply voltage wave, thereby reducing loss and real-

    ising more efficient use of electricity. Using PAM control, 98% of the

    input power supply is used effectively.

    PAM (Pulse Amplitude Modulation)

    Power increasedEfficient voltage increaserealises increased power

    Significant energy savings

    Remarkable reduction in powerloss saves electricity

    Limited powerInsufficient powerwhen needed

    Limited energy savingsElectricity is wasted

    LEV1

    Powerreceiver

    Heatexchanger

    Heatexchanger

    Compressor

    LEV2

    Power Receiver and Twin LEV Control

    Mitsubishi Electric has developed a power receiver and twin linear

    expansion valves (LEVs) circuit that optimise compressor perfor-

    mance. This technology ensures optimum control in response to op-

    erating waveform and outdoor temperature. Operating efficiency has

    been enhanced by tailoring the system to the characteristics of R410Arefrigerant.

  • 8/11/2019 Full Product Line Cataloque 2010 Split-type_air_conditioners

    12/2681

    FUNCTIONS

    Felt Temperature Control

    The i-see Sensor sweeps from side-to-side automatically monitor-

    ing the floor temperature over a wide area spanning 150.

    Econo Cool Energy-Saving Feature

    Econo Cool is an intelligent temperature control feature that adjusts

    the amount of air directed towards the body based on the air-outlet

    temperature. The setting temperature can be raised by as much as

    2C without any loss in comfort, thereby realising a 20% gain in

    energy efficiency. (Function only available during manual cooling operation.)

    The I Feel fuzzy-logic control memorises the most desirable temperature

    setting. If the TOO WARM or TOO COOL button on the remote con-

    troller is pressed, the system adds the choice to the control memory and ad-

    justs the temperature so that the most comfortable temperature is pro-

    vided. That temperature setting is used the next time the unit is turned on.

    Pure White

    Pure white is adopted for the unit colour; white expressing the

    essence of cleanliness and easily matching virtually all interior dcor.

    Auto Vane

    The vane closes automatically when the air conditioner is not

    running, concealing the air outlet and creating a flat surface that is

    aesthetically appealing.

    Econo Cool Mode

    A comfortable room environment is maintained even when setting thetemperature 2C higher than the conventional cooling mode.

    Conventional air conditioners monitor the air temperature at the top

    of a room to control room temperature and fail to take foot-level tem-

    perature, that which has the strongest impact on room comfort, into

    consideration. The i-see Sensor monitors the floor temperature and

    estimates the felt temperature (i.e., the temperature felt by people

    in the room). The airflow speed and temperature are adjusted to

    prevent over-heating/cooling, thereby eliminating the consumption

    of excessive electricity.

    CoolingFloor-level temperatureis monitored to preventexcessive cooling.

    HeatingFloor-level temperatureis monitored to determineif heating is needed.

    Wide Detection

    Conventional Econo Cool

    Ambient temperature 35C 35C

    Set temperature 25C 27C

    30C 29.3C

    Econo Cool on Conventional cooling mode

    14 16 18 20 22 24 26 28

    Perceived temperature

    Temperature distribution (C)

    SW7-1

    OFF

    ON

    OFF

    SW7-2

    OFF

    OFF

    ON

    Energy consumption

    0% (STOP)

    50%

    75%

    I Feel Control

    Demand Function (Onsite Adjustment)

    Area Temperature Monitor

    The i-see Sensor monitors the whole room in sections and directs the

    airflow to areas of the room where the temperature does not match the

    temperature setting. (When cooling the room, if the middle of the room is

    detected to be hotter, more airflow is directed towards it.) This eliminates

    unnecessary heating /cooling and contributes to lower electricity costs.

    Daytime Warmerarea

    Coolerarea

    Nighttime

    Cooling mode

    The demand function can be activated when the unit is equipped

    with a commercially available timer or an On/Off switch is added to

    the CNDM connector (option) on the control board of the outdoorunit. Energy consumption can be reduced up to 100% of the normal

    consumption according to the signal input from outside.

    [Example: Power Inverter Series]

    Limit energy consumption by changing the settings of SW7-1 and

    SW7-2 on the control board of the outdoor unit. The following set-

    tings are possible.

    ENERGY-SAVING

    ATTRACTIVE

    Example: MSZ-FD Series

  • 8/11/2019 Full Product Line Cataloque 2010 Split-type_air_conditioners

    13/26812

    Plasma Duo

    Units are equipped with a pre-filter and two special filters that per-

    form plasma air cleaning and plasma purification functions (Plasma

    Duo). The plasma system remove bad odours and bacterial particu-

    lates of micron- and nanometre-size from the air.

    Wide and Long Airflow

    The wide and long airflow function is especially beneficial for large spaces, helping to ensure that air is well circulated and reaches every corner

    of the room.

    Wide Airflow

    This unique airflow system distrib-

    utes air horizontally over a wide-

    ranging 150in heating mode and

    100in cooling mode. Simply press

    the Wide Swing icon on the

    remote controller to select the de-

    sired airflow from seven different

    patterns.

    Spot airflow (5 patterns)

    SWING

    Area specif ic Full a ir flow

    Long Airflow

    Use this function to ensure that

    the airflow circulates to areas far

    across the room. Press the Long

    Airflow icon on the remote control-

    ler to extend reach up to as far as

    12 metres from the unit.

    AIR QUALITY

    AIR DISTRIBUTION

    This high-performance filter has a much finer mesh compared to stan-

    dard filters, and is capable of capturing minute particulates floating inthe air that were not previously caught.

    High-efficiency Filter

    The filter is charged with static electricity, enabling it to attract and

    capture dust particulates that regular filters dont.

    Air Cleaning Filter

    Catechin is a bioflavonoid by-product of green tea with both antiviral

    and antioxidant qualities. It also has an excellent deodorising effect,

    which is why Mitsubishi Electric uses the compound in its air condi-

    tioner filters. In addition to improving air quality, it prevents the

    spreading of bacteria and viruses throughout the room. Easily re-

    moved for cleaning and maintenance, when the filter is washed regu-

    larly the deodorising action is rated to last more than 10 years.

    Catechin Filter

    Indoor air quality is enhanced by the direct intake of fresh exterior air.

    Fresh-air Intake

    The anti-allergy enzyme filter works to trap allergens such as molds

    and bacteria and decompose them using enzymes retained in the

    filter.

    Anti-allergy Enzyme Filter

    The air outlet vane swings up and down so that the airflow is spread

    evenly throughout the room.

    Horizontal Fin

    The air outlet fin swings from side to side so that the airflow reaches

    every part of the room.

    Vertical Fin

    The oil mist filter prevents oil mist from penetrating into the inner part

    of the air conditioner.

    Oil Mist Filter

    A special process for the entrapment surface improves the filtering

    effect, making the maintenance cycle longer than that of units

    equipped with conventional filters.

    Long-life Filter

    Air conditioner operating time is monitored, and the user is notifiedwhen filter maintenance is necessary.

    Filter Check Signal

    This function features both the Air Cleaning Filter and Anti-allergy

    Enzyme Filter.

    Electrostatic Anti-allergy Enzyme Filter

    In the case of rooms with high ceilings, the outlet-air volume can be

    increased to ensure that air is circulated all the way to the floor.

    High Ceiling Mode

    If the room has a low ceiling, the airflow volume can be reduced for

    less draft.

    Low Ceiling Mode

    The airflow speed mode adjusts the fan speed of the indoor unit

    automatically according to the present room conditions.

    Auto Fan Speed Mode

    The filter has a large capture area and incorporates nanometre-sized

    platinum-ceramic particles that work to kill bacteria and deodourise

    the circulating air.

    Nano Platinum Filter ElectrostaticAnti-allergyNano

    Platinum

  • 8/11/2019 Full Product Line Cataloque 2010 Split-type_air_conditioners

    14/268

  • 8/11/2019 Full Product Line Cataloque 2010 Split-type_air_conditioners

    15/26814

    Rotation, Back-up and 2nd Stage Cut-in Functions

    (1) Rotation and Back-up Functions

    Function Outline

    to a rotation interval setting.

    -

    (2) 2nd Stage Cut-in Function

    Function Outline -

    perature and predetermined settings.

    setting, the standby unit starts (2-unit operation).

    predetermined setting, the standby unit stops (1-

    unit operation).

    System Constraint

    System Sample

    Operation Pattern

    System Image

    O/U : Outdoor unitI/U : Indoor unitR/C : Wired remote controller

    Operation Pattern

    [Back-up function only]

    Start operation

    Error occurs on main unit.

    Main Sub

    [Rotation function] & [Back-up function]

    (Ex: When the request code is 3 13, each unit operates alternately in daily cycle.)

    Start operation

    128 days 128 days

    Main Sub Sub Main

    Error occurs on main unit.

    Main Sub

    MainunitI/U-1

    SubunitI/U-2

    Run

    Stop

    Abnormal condition

    Run

    MainunitI/U-1

    SubunitI/U-2

    Run Stop Run

    Stop

    Abnormal condition

    Run Stop Run

    [2nd stage cut-in function]

    Start operation

    Room temp. >=Set point

    Sub unit starts operation

    Room temp. >=Set point 4C

    Sub unit stops

    MainunitI/U-1

    SubunitI/U-2

    Run

    Stop Run Stop

    O/U-1 O/U-2

    I/U-1

    R/C

    I/U-2

    Subunit

    Mainunit

    SYSTEM CONTROL

    PAR-21MAA Control

    Centralised On/Off Control

    controller, which can control the On/Off function for a maximum of

    eight indoor units.

    COMPO (Simultaneous Multi-unit Operation)

    (Depending on the unit combination, connection of up to four units is

    possible; however, all indoor units must operate at the same settings.)

    System Group Control

    status of up to 16 refrigerant systems.

    MXZ Connection

    M-NET Connection

    controllers) such as the AG-150A.

  • 8/11/2019 Full Product Line Cataloque 2010 Split-type_air_conditioners

    16/2685

    FUNCTIONS

    Cleaning-free Pipe Reuse

    Reuse of Existing Wiring

    The application of pipe reuse technology such as Mitsubishi Electrics original hard alkyl benzene oil makes it possible to reuse the same piping,

    thereby allowing cleaning-free renewal of air conditioning systems that use R22 refrigerant.

    The wiring method has been improved, making it possible to use methods different from that utilized for control and power supply. Units are

    compatible with the dual harness control line/power line method and the separate power supply method. Using a power-supply terminal kit, wire

    can be efficiently reused at the time of system renewal regardless of the method the existing system uses.*Optional. Usage may be limited due to wiring type diameter.

    Wiring/Piping Correction Function*

    The push of a single button is all that is required to confirm that

    piping and wiring are properly connected. Corrections are made au-

    tomatically if a wiring error is detected, eliminating the need for com-

    plicated wiring confirmation work when expanding the number of

    rooms served.

    *This function cannot be used when the outdoor temperature is below 0C.

    The correction process requires 1015 minutes, and only works when the unit is set

    to the Cooling mode.

    Drain Pump

    A built-in drain pump enables drain piping to be raised.

    Pump Down Switch

    Enables smooth and easy recovery of refrigerant. Simply press the

    Flare Connection

    Flare connection to cooling pipe work is possible.

    Wiring recycling problem solved! Compatible with other wiring connection methods*

    Single Harness Control/Power Line Method(Current method)

    Indoor unit (factory-shipped condition) Indoor unit (factory-shipped condition)

    Indoor unitControl board

    PowerIndoor/Outdoor unit

    communication

    JunctionconnectorOutdoor unit

    Indoor unit

    Outdoor unit

    to power

    L N S1 S2 S3

    S1 S2 S3Control/Power3 cores

    Control/Power3 cores

    Power supply

    Dual Harness Control Line/Power Line Method

    Control board

    Junction connectorsreplaced

    PowerIndoor/Outdoor unit

    communication

    S1 S2 S3

    S1 S2 S3Power2 cores

    Control2 cores

    Power supply

    Separate Power Supply Method

    INSTALLATION

    Pump Down Switch

    stop refrigerant recovery

    operation automatically.

    (Valve in refrigerant circuit

    is opened/closed.)

    Outdoor unit control circuit board

    Wiringconfirmation

    istimeconsuming.

    The outdoor unitmatches

    pipesand wiring.

    to power

    L N

    L N

    Indoor unit

    Outdoor unit

    Control board

    Junction connectorsreplaced

    PowerIndoor/Outdoor unit

    communication

    S1 S2 S3

    S1 S2 S3Control2 cores(polarised)

    Power supply

    Power supply

    to power

    to power

    L N

    L NPower2 cores

    Control2 cores

    Control2 cores

    Built-in drain pump efficiently

    pumps out water

    Power supply terminal kit (optional)Power supply terminal kit (optional)

  • 8/11/2019 Full Product Line Cataloque 2010 Split-type_air_conditioners

    17/26816

    Electricity billincreases by

    5%*

    Electricity billincreases by

    25%*

    Open the vents and reach into clean the fan

    Exclusive Quick Clean Kit (Optional)

    cleaner for quick and easy cleaning of the heat exchanger.*

    *It is highly recommended that rubber gloves be worn when cleaning the heat exchanger.Touching it with bare hands may lead to injury.

    Mitsubishi Electrics Quick Clean Body prevents increases

    in electricity cost by as much as 30%*

    Always clean the heat exchanger, fan, and air vent to ensure proper perfor-mance and economical operation.

    *Electricity cost comparison of operation between two units at a fixed temperature;

    one with 8g of dirt on one fan and the other fan clean. Based on in-house data.

    Fan Air vent

    Quick Clean Body

    The cover panel can be quickly removed for washing and the airflow vents can be opened without any special tools, making it easy to clean the

    energy savings.

    -

    method to promote the reduction of CO2emissions. The European

    Commission is confident that this labeling program will contribute to

    educating companies and the public as to the vital importance of un-

    derstanding energy consumption, thereby leading consumers to pur-

    chase products that are both efficient and environmentally friendly.

    Each label contains information pertaining to the amount of energy

    consumed by the unit. Air conditioners with cooling capacities of

    under 12kW are split into seven categories (A-G). Each category is

    classified according to energy consumption (i.e. the Energy Effi-

    -

    cient, symbolized by a green arrow on the label. Less efficient units

    are classified in order of efficiency, with the least efficient units be-

    longing to Category G, the label of which is marked with a red arrow.

    This enables consumers to easily identify the more efficient units

    when they are comparing brands and units at the time of purchase.

    MAINTENANCE

    ENERGY LABELING

    (These classifications are for Split and Multi-Split type air conditioners.)

    Energy Labeling of Air Conditioners

    Outdoor unitIndoor unit

    More efficient

    Less efficient

    Annual energy consumption,

    kWh in cooling mode(Actual consumption will dependon how the appliance is usedand climate.)

    Energy efficiency ratioFull load (the higher the better)

    Type Cooling only Cooling + Heating

    Air cooled Water-cooled

    Heat output kW

    Heating performanceA: higher G: lower

    Noise(dB(A) re 1 pW)

    Further information is containedin product brochures.

    All air conditioners with the cooling capacity under 12kW are concerned.

    Directive defines for each type of product the energy class going from A (more efficient)

    to G (less efficient).

    The energy efficiency class is determined in accordance with the following tables.

    Norm EN 814Air conditionerEnergy Label Directive 2002/31/EC

    Classifications

    Energy Efficiency ClassIn cooling mode

    A 3.20 < EER

    B 3.20 >EER > 3.00

    C 3.00 >EER > 2.80D 2.80 >EER > 2.60

    E 2.60 >EER > 2.40

    F 2.40 >EER > 2.20

    G 2.20 >EER

    Energy Efficiency ClassIn heating mode

    A 3.60 < COP

    B 3.60 >COP > 3.40

    C 3.40 >COP > 3.20D 3.20 >COP > 2.80

    E 2.80 >COP > 2.60

    F 2.60 >COP > 2.40

    G 2.40 >COP

    ProductAir Conditioners

    A B C 1 2 3A B C 1 2 3

    A

    X.Y

    X.YX.Y

    X.Y

    A BCD E F G

    Model Name

    Energy Efficiency Class

    Annual Energy Consumption

    The Annual Energy Consumption is calculated with the total input

    power multiplied by an average of 500 hours per year in cooling

    mode at full load.

    Energy Efficiency Ratio

    Higher EER means better energy efficiency.

    Type of Air Conditioner

    A

    BC

    D

    E

    G

    Energy

    AIR CONDITIONING SYSTEMSManufacturer

    F

    Cooling output kW

    Self-diagnostic Function (Check Code Display)

    Check codes are displayed on the remote controller or the operation

    indicator to inform the user of malfunctions detected.

    Failure Recall Function

    Operation failures are recorded, allowing confirmation when needed.

  • 8/11/2019 Full Product Line Cataloque 2010 Split-type_air_conditioners

    18/2687

    FEATURES

    Opt

    Opt

    Opt

    Opt

    *1

    Opt

    Opt

    Opt

    Opt

    *2

    *1

    Opt

    Opt

    Opt

    Opt

    *2

    80

    *1

    80

    Opt

    Opt

    Opt

    Opt

    *2

    80

    *1

    Opt

    Opt

    Opt

    Opt

    *2

    Opt

    *1

    Opt

    Opt

    Opt

    Opt

    *2

    80

    Opt

    Opt

    Opt

    Opt

    Opt

    *1

    Opt

    Opt

    Opt

    Opt

    22-50*2

    *1

    Opt

    Opt

    Opt

    Opt

    22-50*2

    *1

    80

    Opt

    Opt

    Opt

    Opt

    *2

    80

    *1

    Opt

    Opt

    Opt

    Opt

    *2

    *1

    Opt

    Opt

    Opt

    Opt

    *2

    Opt22-50

    Opt22-50

    Opt22-50

    Opt22-50

    Opt22-50

    Opt22-50

    Opt60/71

    Opt60/71

    Opt60/71

    Opt60/71

    Opt60/71

    22-50 22-50 22-50 22-50 22-50 22-50

    60/71 60/71 60/71 60/71

    60/71 60/71 60/71 60/71

    *1

    Opt

    Opt

    Opt

    Opt

    *2

    *1

    Opt

    Opt

    Opt

    Opt

    *2

    80

    *1

    80

    Opt

    Opt

    Opt

    Opt

    *2

    80

    *1

    Opt

    Opt

    Opt

    Opt

    *2

    Opt

    *1

    Opt

    Opt

    Opt

    Opt

    *2

    35

    Opt

    Opt

    Opt

    Opt

    Opt

    Opt

    DC Inverter

    Joint Lap DC Motor

    Magnetic Flux Vector Sine Wave Drive

    Reluctance DC Rotary Compressor

    Highly Efficient DC Scroll Compressor

    Rare Earth Magnet Rotor(Compressor)

    DC Fan Motor

    Vector-Wave Eco Inverter

    PAM(Pulse Amplitude Modulation)

    Power Receiver and Twin LEV Control

    Grooved Piping

    Felt Temperature Control (i-see Sensor)

    AREA Temperature Monitor

    Econo Cool Energy-saving Feature

    'I-Feel' Control

    Demand Function

    Pure White

    Auto Vane

    Plasma Duo

    Air-cleaning Filter

    Fresh-air Intake

    Anti-allergy Enzyme Filter

    Electrostatic Anti-allergy Enzyme Filter

    High-efficiency Filter

    Catechin Filter

    Oil Mist Filter

    Long-life Filter

    Filter Check Signal

    Horizontal Fin

    Vertical Fin

    High Ceiling Mode

    Low Ceiling Mode

    Auto Fan Speed Mode

    Wide and Long Airflow

    On/off Operation Timer

    "i save" Mode

    Auto Changeover

    Auto Restart

    Low-temperature Cooling

    Low-noise Operation(Outdoor Unit)

    Ampere Limit Aoljustment

    Operation Lock

    Rotation, Back-up and 2nd Stage Cut-in Functions

    PAR-21MAA Control *3

    Centraliesd On/Off Control *3

    System Group Control *3

    M-NET Connection *3

    COMPO *4

    MXZ Connection

    Cleaning-free Pipe Reuse

    Reuse of Existing Wiring

    Wiring/Piping Correction Function

    Drain Pump

    Pump Down Switch

    Flare Connection

    Quick Clean Body

    Self-Diagnosis Function(Check Code Display)

    Failure Recall Function

    Indoor unit

    Outdoor unit

    MSZ-FD20/35/50VA(S) MSZ-GE22/25/35/42/50/60/71VA MSZ-SF15/20VAMSC-

    GE20/25/35

    VB

    MSH-GE50

    VB

    MSH-GA60

    VB

    MSH-GD80

    VB

    MSZ-

    HC25/35VA(B)

    MUZ-FD

    MXZ-2B

    MXZ-3B

    MXZ-4B

    MXZ-5B

    MXZ-8A

    MUZ-GE

    MXZ-2B

    MXZ-3B

    MXZ-4B

    MXZ-5B

    MXZ-8A

    MXZ-2B

    MXZ-3B

    MXZ-4B

    MXZ-5B

    MXZ-8A

    MUZ-HC

    MUH-GA

    MU-GA

    MUH-GE

    MUH-GA

    MUH-GD

    M SERIES

    Technology

    Energy

    Saving

    Attractive

    Air Quality

    Air

    Distribution

    Convenience

    System

    Control

    Installation

    Maintenance

    Functions

    Com

    bination

    Category Icon

    *1 When multiple indoor units connected to an MXZ outdoor unit are running at the same time, simultaneous cooling and heating is not possible.*2 For the possible connectivity of MXZ outdoor units and indoor units, please refer to the list on page 97 for details.

    *3 Please refer to "System Control" on pages 23-24 for details.*4 Please refer to page 52 for details.

  • 8/11/2019 Full Product Line Cataloque 2010 Split-type_air_conditioners

    19/26818

    Opt

    Opt

    Opt

    Opt

    Opt

    Opt

    Opt

    *1

    Opt

    Opt

    Opt

    Opt

    *2

    *1

    Opt

    Opt

    Opt

    Opt

    *2

    80

    *1

    80

    Opt

    Opt

    Opt

    Opt

    *2

    80

    *1

    Opt

    Opt

    Opt

    Opt

    *2

    Opt

    *1

    Opt

    Opt

    Opt

    Opt

    *2

    Opt

    Opt

    *1

    Opt

    Opt

    Opt

    Opt

    *2

    Opt

    Opt

    *1

    Opt

    Opt

    Opt

    Opt

    *2

    80

    Opt

    Opt

    *1

    80

    Opt

    Opt

    Opt

    Opt

    *2

    80

    Opt

    Opt

    *1

    Opt

    Opt

    Opt

    Opt

    *2

    Opt

    Opt

    Opt

    *1

    Opt

    Opt

    Opt

    Opt

    *2

    Opt

    Opt

    Opt

    *1

    Opt

    Opt

    Opt

    *2

    *1

    Opt

    Opt

    Opt

    *2

    80

    *1

    80

    Opt

    Opt

    Opt

    *2

    80

    *1

    Opt

    Opt

    Opt

    *2

    Opt

    *1

    Opt

    Opt

    Opt

    *2

    Opt

    Opt

    Opt

    Opt

    *1

    Opt

    Opt

    Opt

    Opt

    *2

    *1

    Opt

    Opt

    Opt

    Opt

    *2

    80

    *1

    80

    Opt

    Opt

    Opt

    Opt

    *2

    80

    *1

    Opt

    Opt

    Opt

    Opt

    *2

    Opt

    *1

    Opt

    Opt

    Opt

    Opt

    *2

    71

    Opt

    Opt

    Opt

    Opt

    *1

    Opt

    Opt

    Opt

    *2

    Opt

    *1

    Opt

    Opt

    Opt

    *2

    Opt

    80

    *1

    80

    Opt

    Opt

    Opt

    *2

    80

    Opt

    *1

    Opt

    Opt

    Opt

    *2

    Opt

    Opt

    *1

    Opt

    Opt

    Opt

    *2

    Opt

    MFZ-KA25/35/50VA MLZ-KA25/35/50VA SLZ-KA25/35/50VA SLZ-KA25/35/50VAL SEZ-KD25/35/50/60/71VAMS-

    GE50

    VB

    MU-GE

    MS-GA60

    VB

    MS-GD80

    VB

    MU-GA

    MU-GD

    SUZ-KA

    MXZ-2B

    MXZ-3B

    MXZ-4B

    MXZ-5B

    MXZ-8A

    MXZ-2B

    MXZ-3B

    MXZ-4B

    MXZ-5B

    MXZ-8A

    SUZ-KA

    MXZ-2B

    MXZ-3B

    MXZ-4B

    MXZ-5B

    MXZ-8A

    SUZ-KA

    MXZ-2B

    MXZ-3B

    MXZ-4B

    MXZ-5B

    MXZ-8A

    SUZ-KA

    MXZ-2B

    MXZ-3B

    MXZ-4B

    MXZ-5B

    MXZ-8A

    M SERIES S SERIES

    The figures listed in the table are "only when combined with an outdoor unit with the appropriate capacity range". Opt: Separate parts must be purchased.

  • 8/11/2019 Full Product Line Cataloque 2010 Split-type_air_conditioners

    20/2689

    71

    Opt

    Opt

    Opt

    Opt

    Opt

    *1

    Opt

    Opt

    Opt

    Opt

    *2

    Opt

    *1

    Opt

    Opt

    Opt

    Opt

    *2

    Opt

    80

    *1

    80

    Opt

    Opt

    Opt

    Opt

    *2

    80

    Opt

    *1

    Opt

    Opt

    Opt

    Opt

    *2

    Opt

    Opt

    *1

    Opt

    Opt

    Opt

    Opt

    *2

    Opt

    Opt

    Opt

    Opt

    100/125

    Opt

    Opt

    Opt

    35-71

    100-250

    35-140

    Opt

    Opt

    Opt

    Opt

    Opt

    71-250

    Opt

    100-140

    200/250

    100-140

    Opt

    Opt

    Opt

    Opt

    Opt

    Opt

    71

    Opt

    Opt

    Opt

    Opt

    Opt

    100

    Opt

    Opt

    Opt

    Opt

    Opt

    100

    Opt

    Opt

    Opt

    Opt

    Opt

    Opt

    Opt

    *1

    Opt

    Opt

    Opt

    *2

    80

    Opt

    Opt

    *1

    80

    Opt

    Opt

    Opt

    *2

    80

    Opt

    Opt

    *1

    Opt

    Opt

    Opt

    *2

    Opt

    Opt

    Opt

    *1

    Opt

    Opt

    Opt

    *2

    Opt

    100/125

    Opt

    Opt

    Opt

    35-71

    100-250

    35-140

    Opt

    Opt

    Opt

    71-250

    Opt

    100-140

    200/250

    100-140

    Opt

    Opt

    Opt

    Opt

    71

    Opt

    Opt

    Opt

    100

    Opt

    Opt

    Opt

    100

    Opt

    Opt

    Opt

    DC Inverter

    Joint Lap DC Motor

    Magnetic Flux Vector Sine Wave Drive

    Reluctance DC Rotary Compressor

    Highly Efficient DC Scroll Compressor

    Rare Earth Magnet Rotor(Compressor)

    DC Fan Motor

    Vector-Wave Eco Inverter

    PAM(Pulse Amplitude Modulation)

    Power Receiver and Twin LEV Control

    Grooved Piping

    Felt Temperature Control (i-see Sensor)

    AREA Temperature Monitor

    Econo Cool Energy-saving Feature

    'I-Feel' Control

    Demand Function

    Pure White

    Auto Vane

    Plasma Duo

    Air-cleaning Filter

    Fresh-air Intake

    Anti-allergy Enzyme Filter

    High-efficiency Filter

    Catechin Filter

    Oil Mist Filter

    Long-life Filter

    Filter Check Signal

    Horizontal Fin

    Vertical Fin

    High Ceiling Mode

    Low Ceiling Mode

    Auto Fan Speed Mode

    Wide and Long Airflow

    On/off Operation Timer

    "i save" Mode

    Auto Changeover

    Auto Restart

    Low-temperature Cooling

    Low-noise Operation(Outdoor Unit)

    Ampere Limit Aoljustment

    Operation Lock

    Rotation, Back-up and 2nd Stage Cut-in Functions

    PAR-21MAA Control *3

    Centraliesd On/Off Control *3

    System Group Control *3

    M-NET Connection *3

    COMPO *4

    MXZ Connection

    Cleaning-free Pipe Reuse

    Reuse of Existing Wiring

    Wiring/Piping Correction Function

    Drain Pump

    Pump Down Switch

    Flare Connection

    Quick Clean Body

    Self-Diagnosis Function(Check Code Display)

    Failure Recall Function

    Indoor unit

    Outdoor unit

    SEZ-KD25/35/50/60/71VAL PLA-RP35/50/60/71/100/125/140BA(2/3) PEAD-RP35/50/60/71/100/125/140JA

    SUZ-KA

    MXZ-2B

    MXZ-3B

    MXZ-4B

    MXZ-5B

    MXZ-8A

    PUHZ-HRP

    PUHZ-RP

    PUHZ-P

    SUZ-KA

    PUH-P

    PU-P MXZ-3B

    MXZ-4B

    MXZ-5B

    MXZ-8A

    PUHZ-HRP

    PUHZ-RP

    PUHZ-P

    SUZ-KA

    PUH-P

    PU-P

    P SERIESS SERIES

    EnergySaving

    Air Quality

    AirDistribution

    Convenience

    SystemControl

    Installation

    Maintenance

    Functions

    Category Icon

    FEATURES

    Combination

    Technology

    Attractive

    *1 When multiple indoor units connected to an MXZ outdoor unit are running at the same time, simultaneous cooling and heating is not possible.*2 For the possible connectivity of MXZ outdoor units an d indoor units, please refer to the list on page 97 for details.

    *3 Please refer to "System Control" on pages 23-24 for details.*4 Please refer to page 52 for details.

    60-140V200/250

    60-140V200/250

  • 8/11/2019 Full Product Line Cataloque 2010 Split-type_air_conditioners

    21/26820

    Opt

    Opt

    100

    Opt

    Opt

    Opt

    100

    Opt

    Opt

    Opt

    71

    Opt

    Opt

    Opt

    100-140

    200/250

    100-140

    Opt

    Opt

    Opt

    Opt

    35-71

    100-250

    35-140

    Opt

    Opt

    Opt

    71-250

    Opt

    Opt

    00/125

    Opt

    Opt

    Opt

    Opt

    Opt

    35-71

    100-200

    35-140

    Opt

    Opt

    Opt

    Opt

    Opt

    Opt

    Opt

    71-250

    Opt

    Opt

    100-140

    200

    100-140

    Opt

    Opt

    Opt

    Opt

    Opt

    Opt

    Opt

    Opt

    Opt

    Opt

    Opt

    100/125

    Opt

    Opt

    Opt

    Opt

    Opt

    Opt

    Opt

    60-71

    100-250

    60-140

    Opt

    Opt

    Opt

    Opt

    Opt

    Opt

    Opt

    71-250

    Opt

    Opt

    100-140

    200/250

    100-140

    Opt

    Opt

    Opt

    Opt

    Opt

    Opt

    Opt

    Opt

    Opt

    100

    Opt

    Opt

    Opt

    Opt

    Opt

    Opt

    Opt

    Opt

    100

    Opt

    Opt

    Opt

    Opt

    Opt

    Opt

    Opt

    Opt

    50-71

    100-250

    50-140

    Opt

    Opt

    Opt

    Opt

    71-250

    Opt

    Opt

    100-140

    200/250

    100-140

    Opt

    Opt

    Opt

    Opt

    Opt

    Opt

    71

    Opt

    Opt

    Opt

    Opt

    Opt

    100

    Opt

    Opt

    Opt

    Opt

    Opt

    100

    Opt

    Opt

    Opt

    Opt

    Opt

    71

    100-250

    71-140

    Opt

    Opt

    Opt

    71-250

    Opt

    100/125

    250

    125/140

    Opt

    Opt

    Opt

    Opt

    100

    Opt

    Opt

    Opt

    100

    Opt

    Opt

    Opt

    71

    100-250

    71-140

    Opt

    Opt

    Opt

    Opt

    71-250

    Opt

    100-140

    200/250

    100-140

    Opt

    Opt

    Opt

    Opt

    Opt

    100

    Opt

    Opt

    Opt

    Opt

    100

    Opt

    Opt

    Opt

    Opt

    PEAD-RP35/50/60/71/100/125/140JALPEA-

    RP200/250/400/500GA

    PKA-RP35/50HAL

    PKA-RP60/71/100KAL PCA-RP50/60/71/100/125/140KA PCA-RP71/125HA PSA-RP71/100/125/140GA

    PUHZHRP

    PUHZ-RP

    PUHZ-P

    SUZ-KA

    PUH-P

    PU-P PUHZ-RP

    PUHZ-P

    PUHZ-RP

    PUHZ-P

    PUHZ-HRP

    PUHZ-RP

    PUHZ-P

    PUH-P

    PU-P PUHZ-RP

    PUHZ-P

    SUZ-KA

    Opt

    *1

    Opt

    Opt

    *2

    Opt

    MXZ-3B

    80

    Opt

    *1

    80

    Opt

    Opt

    *2

    Opt

    MXZ-4B

    Opt

    *1

    Opt

    Opt

    *2

    Opt

    MXZ-5B

    PUH-P

    PU-P PUHZ-RP

    PUHZ-P

    PUH-P

    PU-P PUHZ-RP

    PUHZ-P

    PUH-P

    PU-P

    P SERIES

    If a numerical figure is listed, the feature is only available with the outdoor unit of that capacity. Opt: Optional parts must be purchased.

    60-140V200/250

    60-140V200/250

    60-140V200/250

    60-140V200/250

    71-140V200/250

    71-140V200/250

  • 8/11/2019 Full Product Line Cataloque 2010 Split-type_air_conditioners

    22/2681

    LimitedTemperatureRangeSettings

    [Japanese]

    [English] [Italian] [German][Spanish]

    [Russian] [Chinese][French]

    Display Example [Operation Mode]

    Dot LCD

    Multi-Ianguage

    COOL / DRY

    Office RestaurantRecommended for

    Lower temperature limit

    Possible temperature range setting

    19(C) 30(C)

    30(C)25(C)

    To prevent excessive coolingLower temperatures cannotbe selected

    Meeting roomRecommended for

    Public facility like public hall

    Recommend to use in Office School / Private school

    Hospital Server room

    CONTROL TECHNOLOGIES

    Newly Developed Advanced MA Remote Controller

    A Progressive Step in the Evolution of Air Conditioning Control

    Dot Liquid-crystal Display Adopted

    The adoption of dot liquid-crystal display (LCD) technology and a

    large display screen for the control panel optimises visibility. Opera-

    tion and control status are easily read at a glance.

    Operation Control Function

    First Multi-language Display in the Industry

    Control panel operation in

    eight different languages.

    Choose the desired language,

    among the following languages.

    Air conditioner operation restricted to

    within a specified operating range

    Set the upper and lower limits for the temperature range during op-

    eration. Excessive heating or cooling is prevented, leading to in-

    creased energy savings.

    Auto-offTimer

    Automatically turns off

    air conditioner

    Set the time for the air conditioner to turn off automatically. The

    timer can be set in the range from 30 minutes up to 4 hours in 30-

    minute intervals.

    OperationLock

    Prevent operation settings

    from being changed

    Units can be set so that the operation mode cannot be changed.

    When Operation Lock is activated, new temperature setting

    commands are not accepted, thereby ensuring that the unit runs in

    the specified (locked in) temperature range. This promotes energy

    savings and prevents erroneous/ mischievous operation.

    The Simple Timerstarts/stops in units of 1 hour in a 72-hour peri-

    od is set at the time of shipment from the factory. It can be changed

    to the Auto-off Timer function using the remote controller.

    Only the administrator can change settings when using the Operation

    Lock mode.

    Easy To Read & Easy To Use

    Energy-efficient Control

    PAR-21MAA

  • 8/11/2019 Full Product Line Cataloque 2010 Split-type_air_conditioners

    23/26822

    Busy time Slow time

    4

    Setting Example (restaurant in summer time)

    Economical &

    Space Saving

    26

    25

    24

    23

    22

    010 12 14 16 18 20 22 24

    Temperaturesetting(C)

    Opening time

    Lunch time Dinner time

    7-pattern setting

    Closing time

    Set to lower temperature Set to higher temperature

    1

    2

    3 5

    6 7

    (hr)

    (Results of cooperative study with Japan Facility Solution Co., Ltd.)

    Setting the temperature 1C

    higher for cooling and 1C lower for

    heating leads to an energy savings

    of approximately 10%. *Based on in-house calculations

    Conventional Inspection Work

    Easy Maintenance Information

    Accumulated operating

    time (x10hr)

    Number of ON/OFF

    times (x100 times)

    Operating

    current (A)

    Heat exchanger

    temperature (C)

    Discharge

    temperature (C)

    Outdoor-air

    temperature (C)

    Intake-air

    temperature (C)

    Heat exchanger

    temperature (C)

    Filter operating

    time* (hr)

    Outdoor UnitCompressor Indoor Unit

    1

    2

    3

    4

    5

    6

    7

    8

    9

    *The filter operating time is the time elapsed since the filter button was reset.

    Discharge temperature 64C

    Indoor Unit Outdoor Unit

    Remove theservice panel

    Measurethe intake-air

    temperature

    Measure the discharge

    temperature

    Measure the outdoor-

    air temperature

    Weekly Timer

    Introduced in Response to Market Demand

    Control temperature on a weekly basis

    Temperature settings and On/Off control can be managed over a

    period of one week using the Weekly Timer. Up to eight setting pat-

    terns per calendar day are possible.

    Easy Maintenance Function (Mr. Slim Power Inverter only)

    Remote controller also lets you set the operating frequency, allowing easier inspection.

    Refrigerant Leakage Check (Mr. Slim Power Inverter only)

    The Mr. Slim Power Inverter units come equipped with a useful new Refrigerant Leakage Check function. Using a

    wired remote controller, it is easy to check if refrigerant has been lost over a long period of use. This reduces service

    time and gives an added sense of safety.

    PAR-20MAA

    Conventional MA

    Remote Controller

    PAC-YT34STA

    Schedule

    Timer PAR-21MAA

    Remote Controller

    Approximate10%Energy Savings

  • 8/11/2019 Full Product Line Cataloque 2010 Split-type_air_conditioners

    24/2683

    SYSTEM CONTROLVersatile system controls can be realised using optional parts, relay circuits, control panels, etc.

    MAJOR SYSTEM CONTROL

    M Series Indoor Unit

    M Series and MXZ Series Outdoor

    Indoor Unit

    Outdoor Unit

    S Series & P Series Indoor Unit

    System Examples

    S Series and MXZ Series Outdoor

    P Series Indoor Unit

    P Series Outdoor

    Details

    Major Optional Parts Required

    Details

    Major Optional Parts Required

    Details

    Major Optional Parts Required

    indoor unit

    Standard equipment (for indoor units compatible with wired remote controllers)

    Details

    Major Optional Parts Required

    Outdoor unit

    Indoor unit

    MAC-399IF-E

    ME remote controller

    (PAR-F27MEA)

    Power supplyunit

    City Multiindoor unit

    Indoor unit

    Indoor unit MAC-821SC-E

    MAC-397IF-E

    Outdoor unit

    Outdoor unit

    Outdoor unit

    Outdoor unit

    PAR-21MAA

    MAC-397IF-E

    PAR-21MAA

    PAR-21MAA Control

    System Group Control

    Centralised On/Off Control

    M-NET Connections

    Indoor unit

    Indoor unit MAC-821SC-E

    MAC-397IF-E

    Outdoor unit Outdoor unit

    Outdoor unit Outdoor unit

    PAR-21MAA

    Outdoor

    unit

    Indoor unit

    MAC-399IF-Esystem controller

    system controller etc)

    Power supplyunit

    City Multiindoor unit

    PAR-21MAA

    Outdoor

    unit

    Indoor unit

    PAR-21MAA

    PAC-SF81MA-E

    system controller

    Power supplykit

    PAR-21MAA

    PAR-21MAA

    Indoor unitIndoor unit

    PAR-21MAA

    MAC-397IF-E

    Indoor unit

    Outdoor unit

    Indoor unit

    Outdoor unit

    Outdoor unit

    Indoor unit

    MAC397IF-E

    PAR-21MAA

  • 8/11/2019 Full Product Line Cataloque 2010 Split-type_air_conditioners

    25/26824

    OTHERS

    2-remote ControllerControl

    With two remote controllers, controlcan be performed locally andremotely from two locations.

    Operation Control byLevel Signal

    Air conditioner can be started/stopped remotely. In addition,On/Off operation by local remotecontroller can be prohibited/permitted.

    Operation Control byPulse Signal

    Remote Display ofOperating Status

    Operating status can bedisplayed at a remote location.

    Allows On/Off operation withtimer*For control by an external

    timer, refer to B OperationControl by Level Signal.

    Timer Operation

    PAR-21MAAPAR-21MAA

    (Example of 1 : 1 system)

    (Example of 1 : 1 system)

    Relay box (to be purchased) locally)

    Relay box (to be purchased) locally)

    Adapter forremoteOn/Off

    Adapter forremoteOn/Off

    PAR-SL97A-E

    PAR-SL97A-E

    (Example of 1 : 1 system)

    PAR-21MAA

    (Example of 1 : 1 system x 2)

    Relay box (to be purchased locally)

    (Example of 1 : 1 system x 2)

    * Set "Main" and "Sub"remote controllers. * When using wired and

    wireless remote controllers

    PAR-SL97A-E

    (Example of Simultaneous Twin)

    (Example of Simultaneous Twin)

    PAR-21MAA

    PAR-21MAAT-E

    PAR-SL97A-E (Except for SLZ)

    PAR-SL99B-E

    PAC-SE55RA-E

    locally)

    Standard functions of PAR-21MAA

    A

    B

    C

    D

    E

    Details Major Optional Parts Required

    System Examples

    Wired remote controller Wireless remote controller

    Remotedisplaypanel

    RemotedisplaypanelPAR-21

    MAA

    Remotecontrolpanel

    RemotecontrolpanelWired remote

    controller

    connected to one group.

    can be used in combination.

    ment of temperature, fan speed, and airflow)can be performed even when remotecontroller operation is prohibited.

    timer.

    Connector

    cable forremotedisplay

    Connector

    cable forremotedisplay

    PAR-SL97A-E

    (Example of 1 : 1 system x 2)

    Relay box (to be purchased locally)

    (Example of 1 : 1 system x 2)

    PAC-SA88HA-E/ PAC-725AD

    (10 pcs. x PAC-SA88HA-E)

    locally)Remotecontrolpanel

    RemotecontrolpanelWired remote

    controller

    received at a remote location.

    received at a remote location (whenchanneled through the PAC-SF40RMno-voltage signal, when channeled throughthe PAC-SA88HA-E DC 12V signal).

    Weekly Timer:On/Off and up to 8 pattern temperatures canbe set for each calendar day. (Initial setting)

    Simple Timer:On/Off can be set once each within 72 hr inintervals of one hour.

    Auto-off Timer:Operation will be switched off after a certaintime elapse. Set time can be changed from30 min. to 4 hr. at 30 min. intervals.*Simple Timer and A uto-off Timercannot be used at the same time.

    locally)

    PAC-SA88HA-E/ PAC-725AD(10 pcs. x PAC-SA88HA-E)

    PAC-SF40RM *Unable to use with wireless remote controller

    locally)

    Remote operation adapter/Connector cable for remote display +Relay box

    Remote operation adapter/Connector cable for remote display +Relay box

    For P Series and S Series Indoor Units

    For M Series Indoor Units (New A-control Models Only)

    1

    2

    Remote On/OffOperation

    Remote Display ofOperation Status

    Control Details Major Optional Parts RequiredSystem Examples Connection Details

    MAC-397IF (Interface)

    box, lead wire, etc. (to bepurchased locally)

    MAC-397IF-E(Interface)

    purchased locally (DC powersource needed)

    Connect the interface to the airconditioner. Then connect thelocally purchased remote controllerto the terminal in the interface.

    Connect the interface to the airconditioner. Then connect thelocally purchased remote controllerto the terminal in the interface.

    On/Off operation is possible froma remote location.

    The operation status(On/Off) or error signals can bemonitored from a remote location.

    Outdoor unit

    Indoor unit

    MAC-397IF-E

    Remote control section

    (to be purchased locally)

    Switch

    Outdoor unit

    Indoor unit

    MAC-397IF-E

    Remote monitor section

    (to be purchased locally)

    Power supply

    Resistance LED

    stopped remotely.( 1 and 2 can be used incombination)

    conditioners can be confirmedremotely.( 1 and 2 can be used incombination)

  • 8/11/2019 Full Product Line Cataloque 2010 Split-type_air_conditioners

    26/2685

    SERIES

  • 8/11/2019 Full Product Line Cataloque 2010 Split-type_air_conditioners

    27/26826

    MSZ-FSERIES MSZ-GSERIES

    MSH-GSERIES MS-GSERIES

    MFZSERIES MLZSERIES

    MSZ-HSERIES

    SELECTION

    Line-up includes seven series.

    Choose the model that best matches room conditions.

    SELECT SERIESSTEP 1

    Wall-mounted Units

    SELECT OUTDOOR UNITSome outdoor units in the line-up have heaters for use in cold regions. Units with an H in the model name are equipped with heaters.

    A multiple series line-up to choose from, each with various outstanding features. In addition to inverter-equipped models,

    constant-speed, floor-standing and cassette models can be selected. Choose the best series to match usage needs.

    Floor-standing/Cassette Units

    Heater Installed

    Inverter

    Super energy-saving

    Energy Rank A

    Ultra-quiet operation

    Cooling and heating operation

    Compatible for connection to

    MXZ Series system

    MXZ connection only

    EER

    ACOP

    A

    EERA COPA

    Superenergy-saving

    Ultra-quiet

    CoolingHeating

    EER

    ACOP

    AEER

    ACOP

    A

    EER

    ACOP

    A

    EER

    ACOP

    AEER

    A

    To confirm compatibility with the MXZ Series

    multi-type system, refer to the MXZ Series page.

    STEP 2

    Selecting a Heater-equipped Model

    In regions with the following conditions, there is a possibility that water resulting from condensation on the outdoor unit when operating in the heating

    mode will freeze and not drain from the base.1) Cold outdoor temperatures (temperature does not rise above 0oC all day)

    2) Areas where dew forms easily (in the mountains, valleys(surrounded by mountains), near a forest, near unfrozen lakes, ponds, rivers or hot springs),

    or areas with snowfall

    To prevent water from freezing in the base, it is recommended that a unit with a built-in heater be purchased. Please ask your dealer representative about

    the best model for you.

    MUZ-GE25/35/42VAH MUZ-GE50VAH SUZ-KA25/35VAH

    25/35

    20-35 20-35 20/25

    25/35 25/35

    22-35 VA

    Superenergy-saving

    Ultra-quiet Cooling

    Heating Ultra-quiet

    CoolingHeating

    CoolingHeating

    CoolingHeating

    CoolingHeating

    CoolingHeating

    MXZ connection onlyCoolingHeating

    MSZ-SSERIES

  • 8/11/2019 Full Product Line Cataloque 2010 Split-type_air_conditioners

    28/2687

    MSZ-FSERIESThe FD Series is designed for optimum cooling/heating performance as well as operationalcomfort. Quiet, energy-saving operation is supported by some of Mitsubishi Electrics latesttechnologies. Advanced functions such as i-see Sensor temperature control and the PlasmaDuo air filtering and purification system raise room comfort levels to new heights.

    MSZ-FD50VA

    Fan diameter has been increased, enabling the motor to run at a slow speedwhile maintaining the air volume, thereby contributing to quieter operation.

    MSZ-GB50VA

    Air inlet ducts have been widened,reducing the pressure loss inthe airflow path.

    Small air inlet ducts in the indoorunit result in loss of pressure inthe airflow path.

    [Energy Efficiency Comparison]

    Size 25

    Size 50

    Size 35

    5.15 5.25

    4.20 4.35

    5.50

    5.00

    4.50

    4.00

    3.50

    3.00

    5.50

    5.00

    4.50

    4.00

    3.50

    3.00

    4.12

    4.62

    3.74

    4.02

    Mitsubishi Electric compressor motors utilize a rotor made

    using a rare earth magnet, the magnetic flux density of which is

    approximately threefold that of the previous ferrite magnet. This

    rare metal magnet provides high density and increased magneticforce, which leads to a reduction in energy consumption.

    Magnet is

    cut for better

    efficiency.

    25VA

    35VA

    Cooling

    Heating

    Cooling

    Heating

    MSZ-FD

    20dB

    20dB

    21dB

    21dB

    21dB

    21dB

    22dB

    22dB

    MSZ-FA

    1dB less

    1dB less

    1dB less

    1dB less

    Line flow fan comparisonSide view of MSZ-FD

    MSZ-FD MSZ-FA

    EER

    ACOP

    A

    Samarium Magnet Rotor Introducedfor DC Fan Motor of Outdoor Units

    The rotor magnet for the DC motors of the

    outdoor units has been changed from ferrite

    to samarium, which has higher magnetic

    flux. Additionally, the magnet is cut and spe-cially shaped for better efficiency.

    KEY TECHNOLOGIES

    Rare Earth Magnet Rotor for Compressor

    Rare Earth Magnet

    (for MSZ-FD)

    23%UP

    21%UP

    10%UP

    15%UP

    MSZ-FD50VA

    MSZ-GB50VA

    MSZ-FD50VA

    MSZ-GB50VA

    3.33

    3.744.00

    3.50

    3.00

    2.50

    2.00

    1.50

    10%UP

    13%UP

    Cooling mode Heating mode

    3.31

    3.03

    MSZ-FA25VA

    MSZ-FD25VA

    MSZ-FA25VA

    MSZ-FD25VA

    MSZ-FA35VA

    MSZ-FD35VA

    MSZ-FA35VA

    MSZ-FD35VA

    Cooling mode Heating mode Cooling mode Heating mode

    Quiet Operation

    Minimum indoor unit operating noise has been reduced by equip-

    ping the unit with a larger blower fan that enables the motor speed

    to be reduced without reducing the air conditioning capacity.

    High Energy Efficiency Energy Rank A for All Models

    Applying the latest inverter

    technologies, such as the use

    of a rare earth magnet in the

    rotor of the DC fan motor, has

    resulted in remarkably high en-

    ergy efficiency and an Energy

    Rank A rating for cooling andheating performance.

    Amazingly Quiet Operation Redesigned for Performance

    The MSZ-FD50VA has a larger fan diameter, wider air inlet in the upper

    section of the indoor unit and a revised airflow path, which has enabled

    operation noise to be reduced by 3dB in both cooling and heating modes.

    High Energy Efficiency

    Power consumption has been reduced by approximately 20% for

    the cooling and heating modes thanks to the incorporation of ournewest inverter technologies. The high energy efficiency of the

    Size 25 units has obtained a rating of more than 5.0 for both coeffi-

    cient of performance (COP) and energy efficiency rating (EER).

    Introducing Size 50 Units Equipped

    with Deluxe Inverter Series

    MSZ-FD25/35/50VA

  • 8/11/2019 Full Product Line Cataloque 2010 Split-type_air_conditioners

    29/26828

    Plasma electrode produces plasma

    Plasma gives particulates a negative charge

    Positive side of the electret filterattracts the negatively chargedparticulates and enzymes neutralise them

    1

    2

    3

    Plasma electrode produces ozone

    Odour-causing particulates trapped

    Odour-causing particulates decomposed by ozone

    1

    2

    3

    FD Series air conditioners are equipped with state-of-the-art air

    cleaning technologies including a pre-filter and two plasma-based

    filtering mechanisms (Plasma Duo) that virtually deodorise and

    purify the air.

    A plasma electrode is mounted inside the

    indoor unit. An electro-discharge processgenerates ozone and plasma, which then

    work together with the two special filters to

    produce dynamic plasma air-purifying perfor-

    mance.

    Plasma Electrode

    Plasma electrode located here

    Plasma Deodorisation

    An electrified anti-allergen enzyme filter is

    incorporated. A combination of static elec-

    tricity charged into the filter and plasma

    generated by the plasma electrode is used

    to catch bacteria, pollen and other aller-

    gens in the air, which are then neutralised

    by the enzymes in the filter.

    Plasma Air Purification

    Clean air

    1

    2

    3

    Dirty air

    Plasmaelectrode

    Platinumcatalystfilter

    Plasma Deodorising Filter

    Clean air

    Dirty air

    Plasmaelectrode

    1

    2

    Electrifiedanti-allergenenzyme filter

    Plasma Purifying Filter

    3

    Deodorising timereduced approx.

    50% (compared toFA Series)

    A nanometre scale-meshed platinum cata-

    lyst deodorising filter catches odourous par-

    ticulates that are in the air. Once trapped,

    the particulates are decomposed and odours

    eliminated by ozone generated from a plasma

    electrode.

    Dust Allergens Bad Odours

    Filterremoves

    [ Effective Range ]Macro NanoParticulate size

    Plasma Air Purificationremoves

    Plasma Deodorisationremoves

    BacteriaPollen

    Mold spores

    Fish odoursPet odours

    Pet odours

    Food odours

    Allergens

    Rubbish odours

    Having pets indoors cangenerate bad smells

    Cooked meats and food scraps

    Pollens, molds, etc.remain inside the home,and bacteria can multiply

    Standard filterscapture dust in the air,but they cannot catchsmaller particulates.

    The FD Series has a plasma-basedsystem with dual functionsair purification and deodorisationthat work to capture smallparticulates that standard filterscannot, and keep indoor-air clean.

    Highly insulated, airtight residences tend to trap odours,allergens like pollen and mold, and bacteria generated indaily life inside the home.

    Wide Detection

    Sensor sweeps from side-to-side automatically monitoring the floor

    temperature over a wide area spanning 150.

    Conventional air conditioners monitor the air temperature at the top

    of a room to control room temperature and fail to take floor-level

    temperature, that which has the strongest impact on room comfort,

    into consideration. The i-see Sensor monitors floor-level tempera-

    ture to ensure that optimum comfort is obtained throughout theroom.Cooling Heating

    Cold air migrates to the floor, and this can

    result in excessive cooling. The i-see Sensor

    monitors the temperature at the floor level

    and adjusts the outlet-air temperature to pre-

    vent over-chilling.

    Warm air migrates to the ceiling, thereby

    failing to warm the floor-level zone. The

    i-see Sensor monitors the temperature at

    the floor level and adjusts the outlet-air tem-

    perature to prevent insufficient warming.

    Floor-level temperatureis monitored to preventexcessive cooling.

    Floor-level temperatureis monitored to determineif heating is needed.

  • 8/11/2019 Full Product Line Cataloque 2010 Split-type_air_conditioners

    30/2689

    Pre-filter

    Plasma purifying filter

    Plasma deodorising filter

    Fan guard

    Vane

    Front panel

    White & Silver Indoor Units

    Indoor units are available in two colours, white or silver. Choose the colour that best matches your room interior.

    Quick Clean Body

    The front panel is detachable and the airflow vents can be opened

    without requiring any special tools, making air conditioner cleaning

    and maintenance easier than ever. Periodic cleaning of the air condi-

    tioner is recommended to ensure that operation efficiency and

    energy savings are maximised.

    What is Ozone? Ozone density during the ozone shower is safeOzone (03) is a very unstable molecule that slowly transforms itself

    into oxygen (02) and nascent oxygen (O). Splitting the nascent oxygen

    creates the oxidising ability to sterilise and deodorise.

    O2 O3 O2 (O)+ +Ozone OxygenOxygen Nascent OxygenHigh voltage

    MSZ-FD Series units are equipped with a Mold Fighter function

    designed to suppress the growth of mold spores. The plasma elec-

    trode generates ozone, which then attacks the spores and reduces

    growth by approximately 20%.

    O3

    O3OO O3

    Mold Fighter Mechanism

    Before ozone attack After ozone attack

    Mold spore is eliminated

    Mold spores Dead mold sporeOzone attackscell membrane

    Cellmembrane

    Ozone

    Ozone shower

    O3

    core

    0.1ppm inside indoor unit

    Within the upper limit of the acceptable range for ozone gas

    density in work environments.

    [Safety limit advised by the Japan Society for Occupational Health.]

    0.01ppm or lower in room

    Below the average ozone density in coastal or forested regions.

    MSZ-FD25/35/50VA MSZ-FD25/35/50VAS

    White Silver

    The inner fan is placed within ready reach,

    for handy cleaning.

    The exclusive Quick Clean Kit is easily connected to

    household vacuum cleaners for quick and convenient

    cleaning of the heat exchanger and fan.

    Wearing gloves is highly recommended when cleaning the heat exchanger, because touching it with bare hands can cause injury.

    Proper maintenancekeeps electricity

    cost low

    Step 1Following the use of thecooling mode, the ozonegenerated by the plasmaelectrode is distributedthroughout the indoor unitin approximately 15 minutes.

    Step 2The fan is turnedon, and the heatexchanger is driedin approximately25 minutes.

    Fan speed very low

  • 8/11/2019 Full Product Line Cataloque 2010 Split-type_air_conditioners

    31/26830

    Inverter Heat Pump

    Type

    Indoor Unit

    Outdoor Unit

    Power

    Supply

    Cooling

    Heating

    Operating Current (max)

    Indoor

    Unit

    OutdoorUnit

    Ext.

    Piping

    Guaranteed Operating Range

    [Outdoor]

    Source

    Outdoor (V/Phase/Hz)

    Capacity

    Total Input

    EER

    SPL

    Air Volume

    Capacity

    Total Input

    COP

    SPL

    Air Volume

    Input

    Operating Current (max)

    Dimensions

    Weight

    Breaker Size

    Dimensions

    Weight

    Operating Current (max)

    Breaker Size

    Diameter

    Max. Length

    Max. Height

    Rated

    Min - Max

    Rated

    EEL Rank

    Indoor Unit [Lo-Mid-Hi-SHi*2]

    Outdoor Unit [Rated]

    Indoor Unit [Lo-Mid-Hi-SHi*2]

    Outdoor Unit [Rated]

    Rated

    Min - Max

    Rated

    EEL Rank

    Indoor Unit [Lo-Mid-Hi-SHi*2]

    Outdoor Unit [Rated]

    Indoor Unit [Lo-Mid-Hi-SHi*2]

    Outdoor Unit [Rated]

    Rated

    H x W x D

    H x W x D

    Liquid / Gas

    Out-In

    Out-In

    Cooling

    Heating

    kW

    kW

    kW

    dB(A)

    dB(A)

    m3/min

    m3/min

    kW

    kW

    kW

    dB(A)

    dB(A)

    m3/min

    m3/min

    kW

    A

    mm

    kg

    A

    mm

    kg

    A

    A

    mm

    m

    moC

    oC

    MSZ-FD25VA(S)*1

    MUZ-FD25VA

    2.5

    1.1 - 3.5

    0.485

    5.15

    A

    20 - 29 - 36 - 42

    46

    4.6 - 6.3 - 8.6 - 11.2

    35.2

    3.2

    1.5 - 5.5

    0.610

    5.25

    A

    20 - 29 - 36 - 43

    46

    4.5 - 6.7 - 9.2 - 12.1

    32.8

    10.0

    0.031

    0.4

    295 - 798 - 257

    12

    10

    550 - 800 - 285

    36

    9.60

    10

    6.35 / 9.52

    20

    12

    -10 ~ +46

    -15 ~ +24

    3.5

    1.1 - 4.0

    0.850

    4.12

    A

    21 - 29 - 36 - 43

    47

    4.6 - 6.3 - 8.6 - 11.2

    36.3

    4.0

    1.5 - 6.3

    0.865

    4.62

    A

    21 - 29 - 36 - 44

    50

    4.7 - 6.7 - 9.2 - 12.5

    37.8

    10.0

    0.033

    0.4

    295 - 798 - 257

    12

    10

    550 - 800 - 285

    36

    9.60

    10

    6.35 / 9.52

    20

    12

    -10 ~ +46

    -15 ~ +24

    5.0

    1.5 - 5.8

    1.500

    3.33

    A

    29 - 39 - 45 - 52

    54

    6.3 - 8.9 - 11.2 - 14.8

    49.0

    5.8

    1.5 - 7.8

    1.550

    3.74

    A

    27 - 37 - 43 - 50

    56

    5.5 - 8.9 - 11.2 - 14.8

    49.0

    16.0

    0.060

    0.5

    295 -798 -257

    12

    16

    850 - 840 - 330

    55

    15.5

    16

    6.35 / 12.7

    30

    15

    -10 ~ +46

    -15 ~ +24

    MSZ-FD35VA(S)*1

    MUZ-FD35VA

    MSZ-FD50VA(S)*1

    MUZ-FD50VA

    Outdoor power supply

    230 / Single / 50

    *1 MSZ-FD VAS is silver.

    *2 SHiSuper High

    MUZ-FD25/35VA MUZ-FD50VA

    EER

    ACOP

    A

    Optional

    Optional Optional

    Optional

    Indoor Unit Outdoor Unit

    RemoteController

    MSZ-F SERIES

    White

    Silver

    MSZ-FD25/35/50VA

    MSZ-FD25/35/50VAS

  • 8/11/2019 Full Product Line Cataloque 2010 Split-type_air_conditioners

    32/2681

    MSZ-G SERIESThe standard model MSZ-G units provide excellent energy savings and operation is

    impressively silent. A vast series line-up is ready to ensure comfortable room

    environments in response to your air conditioning needs.

    MSZ-GE22/25/35/42/50VA MSZ-GE60/71VA

    Stylish and Compact

    800mm

    Fits neatly above800mm-wide doors.

    Quiet Operation

    A Silent Mode setting has been added to the fan speed settings,

    ensuring super-quiet operation below 20dB for model sizes 35 and

    under. Perfect for the bedroom; its so quiet youll check to see if its on.

    Wide Line-up

    Seven different indoor units (Model 22-71) and 10 outdoor units are

    available to meet your diversified air conditioning needs.

    Nano Platinum Filter

    This filter incorporates nanometre-sized platinum-ceramic particles

    that generate stable antibacterial and deodourising effects. The size

    of the three-dimensional surface has been increased as well, enlarg-

    ing the filter capture area. These features give the Nano Platinum

    Filter of the MSZ-GE60/71 models better dust collection perfor-

    mance than conventional filters. The superior air-cleaning effective-

    ness raises room comfort yet another level.

    It is okay to wash the filter with water

    (air-cleaning effect is maintained)

    In the case of MSZ-GE22-50

    Outdoor Units for Cold Region

    Single split-type outdoor units are available in both standard and

    heater-equipped units. An electric heater is installed in each unit to

    prevent freezing in cold outdoor environments.

    MUZ-GE25/35/42VA MUZ-GE50VA MUZ-GE25/35/42VAH MUZ-GE50VAH

    Standard Units Heater Installed

    i save Mode

    i save is a simplified setting function that recalls the preferred

    (preset) temperature by pressing a single button on the remote con-

    troller. Press the same button twice in repetition to immediately

    return to the previous temperature setting. Using this function con-

    tributes to comfortable, waste-free operation, realising the most

    suitable air conditioning settings and saving on power consumption

    when, for example, leaving the room or going to bed.

    Rank A Energy Savings Achieved for Entire Range of Series

    All models in the series, from the low-capacity 25 to the high-capacity 71, have achieved the Rank A energy-savings rating. For home use, such

    as in bedrooms and living rooms, to light commercial use, such as in offices, our air conditioners are contributing to reduced energy consumptionin a wide range.

    EER

    ACOP

    A

    Only 798mm

    Only

    19dB

    MSZ-GE22/25/35/42/50VA

    MSZ-GE60/71VA

    Temperature can be preset to 10C when heating in the i-save mode

    (except when connected to MXZ-8A140VA).

    22-35

    22oc 18oc

    Heating Heating

    3D surface (Waved surface)

    Comparison with MSZ-GC25/35/50VA, GA60/71VA.Cooling Heating

    COP

    4.21

    Rank ARank A Rank A Rank A Rank A Rank A

    COP4.57

    EER4.05

    COP4.19

    EER3.46

    COP3.62

    EER3.30

    COP3.71

    COP3.76

    EER3.26

    COP3.76

    MSZ-GE25VA MSZ-GE35VA MSZ-GE42VA MSZ-GE50VA MSZ-GE60VA MSZ-GE71VA

    22%UP

    19%UP

    24%UP

    11%UP 9%

    UP

    EER3.40

    9%UP

    9%UP

    7%UP 11%

    UP

    14%UP

    EER4.59

    An elegant, high-quality look is achieved through the new stylish

    design adopted for indoor units. The simple ergonomic square shape

    and pure white color express a sense of sophistication that matches

    well with virtually any interior dcor.

    MSZ-GE22/25/35/42/50VA

    (25/35/42/50)

    60/71

    NanoPlatinum

  • 8/11/2019 Full Product Line Cataloque 2010 Split-type_air_conditioners

    33/26832

    Inverter Heat PumpType

    Indoor Unit

    Outdoor Unit

    PowerSupply

    Cooling

    Heating

    Operating Current (max)

    Indoor

    Unit

    OutdoorUnit

    Ext.Piping

    Guaranteed Operating Range

    [Outdoor]

    Source

    Outdoor (V/Phase/Hz)

    Indoor (V/Phase/Hz)

    Capacity

    Total Input

    EER

    SPL

    Air Volume

    Capacity

    Total Input

    COP

    SPL

    Air Volume

    Input

    Operating Current (max)

    Dimensions

    Weight

    Breaker Size

    Dimensions

    Weight

    Operating Current (max)

    Breaker Size

    DiameterMax. Length

    Max. Height

    Rated

    Min - Max

    Rated

    EEL Rank

    Indoor Unit [Silent-Lo-Mid-Hi-SHi*1]

    Outdoor Unit [Rated]

    Indoor Unit [Silent-Lo-Mid-Hi-SHi*1]

    Outdoor Unit [Rated]

    Rated

    Min - Max

    Rated

    EEL Rank

    Indoor Unit [Silent-Lo-Mid-Hi-SHi*1]

    Outdoor Unit [Rated]

    Indoor Unit [Silent-Lo-Mid-Hi-SHi*1]

    Outdoor Unit [Rated]

    Rated

    H x W x D

    H x W x D

    Liquid / Gas

    Out-In

    Out-In

    Cooling

    Heating

    kW

    kW

    kW

    dB(A)

    dB(A)

    m3/min

    m3/min

    kW

    kW

    kW

    dB(A)

    dB(A)

    m3/min

    m3/min

    kW

    A

    mm

    kg

    A

    mm

    kg

    A

    A

    mm

    m

    moC

    oC

    MSZ-GE25VA

    MUZ-GE25VA(H)

    2.5

    1.1 - 3.5

    0.545

    4.59

    A

    19 - 21 - 29 - 36 - 42

    47

    4.1 - 4.8 - 6.7 - 9.1 - 11.3

    32.6

    3.2

    1.3 - 4.5

    0.700

    4.57

    A

    19 - 21 - 29 - 36 - 42

    48

    4.1 - 4.8 - 6.6 - 9.1 - 11.5

    34.7

    7.4

    0.023

    0.4

    295 - 798 - 232

    10

    -

    550 - 800 - 285

    30

    7.0

    10

    6.35 / 9.52

    20

    12

    -10 ~ +46

    -15(-20) ~ +24

    MSZ-GE22VA

    N/A*2

    -

    -

    -

    -

    -

    19 - 21 - 29 - 36 - 42

    -

    4.1 - 4.8 - 6.7 - 9.1 - 11.3

    -

    -

    -

    -

    -

    -

    19 - 21 - 29 - 36 - 42

    -

    4.1 - 4.8 - 6.6 - 9.1 - 11.5

    -

    -

    0.023

    0.4

    295 - 798 - 232

    10

    -

    -

    -

    -

    -

    6.35 / 9.52

    -

    -

    -

    -

    3.5

    1.1 - 4.0

    0.865

    4.05

    A

    19 - 22 - 30 - 36 - 43

    47

    4.1 - 4.8 - 6.7 - 9.1 - 12.7

    36.3

    4.0

    1.6 - 5.3

    0.955

    4.19

    A

    19 - 22 - 30 - 36 - 42

    48

    4.1 - 4.8 - 6.7 - 9.1 - 11.5

    34.8

    8.6

    0.029

    0.4

    295 - 798 - 232

    10

    -

    550 - 800 - 285

    33

    8.2

    10

    6.35 / 9.52

    20

    12

    -10 ~ +46

    -15(-20) ~ +24

    MSZ-GE35VA

    MUZ-GE35VA(H)

    Outdoor power supply

    230 / Single / 50

    4.2

    0.9 - 4.8

    1.215

    3.46

    A

    26 - 30 - 35 - 40 - 46

    50

    5.8 - 6.8 - 8.6 - 10.4 - 12.8

    36.3

    5.4

    1.4 - 6.0

    1.460

    3.70

    A

    26 - 30 - 35 - 40 - 46

    51

    5.8 - 7.0 - 8.6 - 10.4 - 13.1

    34.8

    10.0

    0.03

    0.4

    295 - 798 - 232

    10

    -

    550 - 800 - 285

    36

    9.6

    10

    6.35 / 9.52

    20

    12

    -10 ~ +46

    -15(-20) ~ +24

    MSZ-GE42VA

    MUZ-GE42VA(H)

    7.1

    2.4 - 8.7

    2.130

    3.33

    A

    30 - 37 - 41 - 45 - 49

    55

    9.7 - 11.5 - 13.3 - 15.4 - 17.8

    50.1

    8.1

    2.2 - 9.9

    2.110

    3.83

    A

    30 - 37 - 41 - 45 - 49

    55

    10.2 - 11.5 - 13.3 - 15.4 - 17.8

    55.0

    16.6

    0.058

    0.5

    325 - 1100 - 238

    16

    -

    880- 840- 330

    53

    16.1

    20

    9.52 / 15.88

    30

    15

    -10 ~ +46

    -15 ~ +24

    MSZ-GE71VA

    MUZ-GE71VA

    *1 SHiSuper High *2 MSZ-GE22 is for MXZ connection only.

    MSZ-GE50VA

    MUZ-GE50VA(H)

    5.0

    1.4 - 5.5

    1.515

    3.30

    A

    28 - 33 - 38 - 44 - 49

    54

    6.5 - 7.8 - 9.6 - 11.9 - 15.1

    49.0

    5.8

    1.4 - 7.3

    1.565

    3.71

    A

    28 - 33 - 37 - 43 - 48

    56

    6.5 - 7.9 - 9.6 - 12.2 - 14.5

    49.0

    13.0

    0.043

    0.5

    295 - 798 - 232

    10

    -

    850 - 840 - 330

    54

    12.5

    16

    6.35 / 12.7

    30

    15

    -10 ~ +46

    -15(-20) ~ +24

    MSZ-GE60VA

    MUZ-GE60VA

    6.0

    1.5 - 7.5

    1.760

    3.40

    A

    29 - 37 - 41 - 45 - 49

    55

    9.8 - 11.3 - 13.4 - 15.6 - 18.3

    40.9

    6.8

    2.0- 9.3

    1.770

    3.84

    A

    29 - 37 - 41 - 45 - 49

    55

    9.8 - 11.3 - 13.4 - 15.6 - 18.3

    49.2

    14.5

    0.062

    0.5

    325- 1100- 238

    16

    -

    880- 840- 330

    50

    14.0

    20

    6.35 / 15.88

    30

    15

    -10 ~ +46

    -15 ~ +24

    MUZ-GE25/35/42VA(H)

    Indoor Unit

    MUZ-GE50VA(H)

    MUZ-GE60/71VA

    MSZ-GE22/25/35/42/50VA

    MSZ-GE22/25/35/42/50VA

    MSZ-GE60/71VA

    MSZ-GE60/71VA

    Outdoor Unit

    MSZ-G SERIES

    RemoteController

    Remote

    Controller

    EER

    ACOP

    A

    Optional

    Optional Optional Optional

    60/71 60/71

    2 5 - 50 2 5 - 50

    Optional

    ElectrostaticAnti-allergy

    Optional

    60/71 60/71

    NanoPlatinum

  • 8/11/2019 Full Product Line Cataloque 2010 Split-type_air_conditioners

    34/2683

    MSZ-H SERIESCompact, high-performance indoor and outdoor units and advanced invertertechnologies provide superior energy savings and comfort in all rooms.

    MSZ-HC25/35VA(B)

    Operating Range

    Stylish Design with Flat Panel Front

    A stylish flat panel design is employed for the front of the indoor unit. The simple look matches room

    aesthetics.

    Silent Operation

    Quiet, relaxing space is within reach. Operational noise is a low 26dB.

    Operation is so silent you might even forget the air conditioner is on.

    Wide Operating Range

    All units offer powerful start-up output to quickly eliminate the gap

    between temperature setting and actual room temperature. From

    cooling on the hottest summer day to heating on a cold winter night,

    once the desired temperature is reached, a stable and comfortable roomtemperature is maintained.

    Compact