FU Series - filtrec.it cataloghi/idraulica/en/FU1250 - FU2550.pdf · Ordering information...
Transcript of FU Series - filtrec.it cataloghi/idraulica/en/FU1250 - FU2550.pdf · Ordering information...
![Page 1: FU Series - filtrec.it cataloghi/idraulica/en/FU1250 - FU2550.pdf · Ordering information Filtration Unit FU 1250 MODEL 4 040 FLOW RATE B SEALS ELECTRIC MOTOR 01 VERSION T MODEL ELECTRIC](https://reader031.fdocuments.in/reader031/viewer/2022022721/5c676a7c09d3f226588bda7e/html5/thumbnails/1.jpg)
w w w . f i l t r e c . c o m FU1250 & FU2550
HYDRAULIC FILTRATION
Technical information
• Support frame and filter housing: carbon steel, painted, mounted on 4 wheels (2 are lockable).• Three phase electric motor: 1,1 kW, 4 poles, 230/440 V 50 Hz for FU1250
3 kW, 2 or 4 poles, 230/440 V 50 Hz for FU2550• Pump protection: Y type filter, 500 µm.• Pump: screw pump with integrated safety valve set at 5 bar, flow rates:
40 l/min for FU12504T80 l/min for FU25504T160 l/min for FU25502T
Overall dimensions (LxPxH): 700 x 1.050x 1.250 mm for FU1250700 x 1.050 x 1.400 mm for FU2550
Weight: kg 155 approx for FU1250 (kg 160 for version /01)kg 175 approx for FU2550 (kg 180 for version /01)
A filter element must be fitted in the filter housing before start:See page 3.
Working temperature: 0°C +80°C
Fluid compatibility (acc.to ISO 2943):Full with fluids ISO Cat.H (except HFA-HFC-HFD/R -HPA)Viscosity: from 30 cSt to 1000 cStFor use with other fluids please contact the FILTREC Customer Service ([email protected])
Fram
eEl
emen
tC
om
mon
FU SeriesHydraulic oil transfer and filtration mobile unit
The unit is supplied complete with a Use and Maintenance Manual and it can be used only byauthorized operators, that have read and understood completely the Manual.
The FU units are CE certified
![Page 2: FU Series - filtrec.it cataloghi/idraulica/en/FU1250 - FU2550.pdf · Ordering information Filtration Unit FU 1250 MODEL 4 040 FLOW RATE B SEALS ELECTRIC MOTOR 01 VERSION T MODEL ELECTRIC](https://reader031.fdocuments.in/reader031/viewer/2022022721/5c676a7c09d3f226588bda7e/html5/thumbnails/2.jpg)
Ordering information
Filtration Unit
FU 1250
MODEL
4 040
FLOW RATE
B
SEALS
ELECTRICMOTOR
01
VERSION
T
MODEL
ELECTRIC MOTOR
1250 fits 1 x filter element RU1250
2550 fits 1 x filter element RU2550
2 2 poles electric motor (FU2550 only)
4 4 poles electric motor
ELECTRICMOTOR
T three phase electric motor
FLOW RATE
040 flow rate 40 l/min (FU12504T)
080 flow rate 80 l/min (FU25504T)
160 flow rate 160 l/min (FU25502T)
SEALS
B NBR
VERSION
00 basic version
01 with contamination monitor
FU1250 & FU25502
![Page 3: FU Series - filtrec.it cataloghi/idraulica/en/FU1250 - FU2550.pdf · Ordering information Filtration Unit FU 1250 MODEL 4 040 FLOW RATE B SEALS ELECTRIC MOTOR 01 VERSION T MODEL ELECTRIC](https://reader031.fdocuments.in/reader031/viewer/2022022721/5c676a7c09d3f226588bda7e/html5/thumbnails/3.jpg)
Filter elements
The filter element must be replaced:
1. When the oil transfer is completed (when used as oil transfer unit).2. When the target cleanliness class is reached (when used as off line filtration unit); (more filter
elements could be necessary to reach it, depending on the oil volume to be cleaned and from the initial contamination level).
3. When both the differential pressure indicators show the red sector.4. When a different filter media is required.
FILTER ELEMENT FITS FILTRATION
RU1250G03B FU1250 ß4,5 µm (C) >1000
RU1250G10B FU1250 ß12 µm (C) >1000
RU1250GW10B FU1250 ß12 µm (C) >1000 + water absorber
RU2550G03B FU2550 ß4,5 µm (C) >1000
RU2550G10B FU2550 ß12 µm (C) >1000
RU2550GW10B FU2550 ß12 µm (C) >1000 + water absorber
FU1250 & FU2550 3
![Page 4: FU Series - filtrec.it cataloghi/idraulica/en/FU1250 - FU2550.pdf · Ordering information Filtration Unit FU 1250 MODEL 4 040 FLOW RATE B SEALS ELECTRIC MOTOR 01 VERSION T MODEL ELECTRIC](https://reader031.fdocuments.in/reader031/viewer/2022022721/5c676a7c09d3f226588bda7e/html5/thumbnails/4.jpg)
1100
650500
1250
700
1050
500
700
1250
650
1050
1100
icount PD
Overall dimensions
FU1250 & FU2550
VERSION “FU1250**00”
VERSION “FU1250**01”
4
![Page 5: FU Series - filtrec.it cataloghi/idraulica/en/FU1250 - FU2550.pdf · Ordering information Filtration Unit FU 1250 MODEL 4 040 FLOW RATE B SEALS ELECTRIC MOTOR 01 VERSION T MODEL ELECTRIC](https://reader031.fdocuments.in/reader031/viewer/2022022721/5c676a7c09d3f226588bda7e/html5/thumbnails/5.jpg)
FU1250 & FU2550
1100
650500
1250
700
1400
1050
650500
1100
700
1250
1400
1050
icount PD
Overall dimensions
VERSION “FU2550**00”
VERSION “FU2550**01”
5
![Page 6: FU Series - filtrec.it cataloghi/idraulica/en/FU1250 - FU2550.pdf · Ordering information Filtration Unit FU 1250 MODEL 4 040 FLOW RATE B SEALS ELECTRIC MOTOR 01 VERSION T MODEL ELECTRIC](https://reader031.fdocuments.in/reader031/viewer/2022022721/5c676a7c09d3f226588bda7e/html5/thumbnails/6.jpg)
ELECTRIC DIAGRAM
L1
L2
L3
PE
SUPPLY & RELAY CABLE
OUTLET TO MONITOR
IPD
BLUERED8
7
380V
24V
L1
L2
L3
PE
*
VERSION “00”
VERSION “01”
FU1250 & FU25506
![Page 7: FU Series - filtrec.it cataloghi/idraulica/en/FU1250 - FU2550.pdf · Ordering information Filtration Unit FU 1250 MODEL 4 040 FLOW RATE B SEALS ELECTRIC MOTOR 01 VERSION T MODEL ELECTRIC](https://reader031.fdocuments.in/reader031/viewer/2022022721/5c676a7c09d3f226588bda7e/html5/thumbnails/7.jpg)
HYDRAULIC SCHEME
COMPONENTS LIST
M
INLET
OUTLET
0.35 bar
6 bar
1
2
3
4
5
5
5
5
6
7
8
9
10
11FU**00
icountPDM
INLET
OUTLET
0.35 bar
6 bar
9
2
1
3
4
6
7
85
12
13
5
10
11FU**01
ITEM DESCRIPTIONMODEL
FU12504T FU25504T FU25502T
1Inlet flexible hose,dia,length, with
rigid endsTF-IN-42-5000 TF-IN-48-5000 TF-IN-60-5000
2 Suction filter “Y” type 1” ¼ Y filter 1” ½ Y filter 2” Y filter
3Screw pump (l/min) withintegrated safety valve
Screw pump 40 l/min Screw pump 80 l/min Screw pump 160 l/min
4 Electric motor TR_4P_kW1,1_V230/440 TR_4P_kW3_V230/440 TR_2P_kW3_V230/440
5 Sampling port Minimess type 1620 ISO228 G1/4"
6 Pressure gauge 213-53-63 0-16 bar G1/4” rad.
7 Visual clogging indicator 2,5 bar V02
8 Visual clogging indicator 5 bar V05
9 Air drain valve complete with microhose ART1800
10 Check valve VU114-5PSI
11Outlet flexible hose,dia,length,
with rigid endsTF-OUT-42-5000
12 Oil condition monitor CAMLI1
13 Flow regulator F600-B
FU1250 & FU2550
7
![Page 8: FU Series - filtrec.it cataloghi/idraulica/en/FU1250 - FU2550.pdf · Ordering information Filtration Unit FU 1250 MODEL 4 040 FLOW RATE B SEALS ELECTRIC MOTOR 01 VERSION T MODEL ELECTRIC](https://reader031.fdocuments.in/reader031/viewer/2022022721/5c676a7c09d3f226588bda7e/html5/thumbnails/8.jpg)
Technical information may change without notice
FU1250 & FU2550 w w w . f i l t r e c . c o m
CT8
0-r
ev.0
0-0
4/1
8
1. icountPD mount points to suit M5 socket head cap screws2. digital display3. M16x2 test points4. Fluid compatibility – Blue band = Mineral based oils5. Communication cable – M12, 8-pin socket communication cable (150 mm flying lead)6. Supply and Limit relay – M12, 8-pin plug cable (150 mm flying lead)
Version “01” is equipped with an oil condition monitor, type Parker icountPD, very useful whenthe unit is used for a loop filtration of the oil contained in a reservoir, to clean it to a certaincleanliness level.
The display of the oil condition monitor continuously shows the cleanliness class and RH (RelativeHumidity) of the oil passing through the unit, so that you can verify when the target cleanlinessclass is reached (more filter elements could be necessary to reach it, depending on the oilvolume to be cleaned and from the initial contamination level).
OIL CONDITION MONITOR (for version “01” only)
12 3
4
5
6